MODEL 8630 PRESSURA ROOM PRESSURE MONITOR

Similar documents
MODEL 8631-CRM/8631-CRC PRESSURA CLEAN ROOM PRESSURE MONITOR/CONTROLLER

MODEL 8635 SUREFLOW ROOM PRESSURE MONITOR

MODEL 8630-CRC-S, 8630-CRC-P PRESSURA CLEAN ROOM PRESSURE CONTROLLER

MODEL 8631-HM(-BAC)/8631-HC(-BAC) PRESSURA ROOM PRESSURE MONITOR/CONTROLLER

MODEL 8636 / 8636-LN / 8636-BAC SUREFLOW ROOM PRESSURE CONTROLLER

MODEL RPM10/RPM20 (-LON)/RPM20-CC PRESSURA ROOM PRESSURE MONITOR

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER

MODEL RPC30 (-LON) PRESSURA ROOM PRESSURE CONTROLLER

Model FHS5 Slimline Display Interface for FHC50/FHM10 P/N Installation Instructions

RPM1600 Series Room Pressure Monitors

STANDARD TRAVERSE SYSTEMS FOR LDV, PDPA AND PIV

Volatile Organic Compounds Probe Maintenance Application Note TSI-149

WINDSHIELD WIPER SERVICE KIT

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light

Pro-Swirl Manifold Air Heater

CoolWave 2 Phase Control Board and Cable Replacement Kit

SWM Series Wall Mount

TMS Series MP46x Flex Probes* Installation Instructions

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

Sivoia QEDTM Installation Instructions

Sivoia QED roller 20TM. Installation Instructions

Blow Off Valve Retrofit Kit

Sivoia QED R Installation Instructions Please Leave for Occupant

MODEL ELC-12/40-CVM-D BATTERY CHARGER

1 Match Shade to Window. Sivoia QEDTM Installation Instructions

StreetHeat SR-60 Heat Soak Button Retrofit Installation Instructions

AT120A-E; AT140A-E; AT150A,B,D-F; AT160B; AT175A-D,F Transformers

MODEL ELC-12/60-D BATTERY CHARGER

is10 Spa-Side Remote Installation Guide (For IntelliTouch and CP3800 series systems)

AIR VELOCITY METER ALNOR MODEL AVM410 AIRFLOW INSTRUMENTS MODEL TA410

NOTICE: The information contained on the following page(s) was produced prior to May 1, On that date Reznor became part of Nortek, Inc.

AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Micro Motion. CMF400 Sensor. Installation Instructions. Quick Reference Guide P/N , Rev. D May 2003

Prestige Series Edge-Lit LED Sign IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Item. Table 1. Circuit Breaker Replacement Kit 1. Item Part No. Description QTY. Remarks No. Includes. Items Items EE55781 WORK SAFELY!

Outdoor Installation Using an Electronic LED Power Supply (TE-60L-12)

ATLAS TRANSFER CASES CABLE SHIFTER units built before 4/30/12

TCU Flushing Manifold and RTD Installation

HTX/STX UNIVERSAL TAPERED KEYLESS SPIDER

PIL0478 ISSUE 01/ 07/16

DRAWING NO WI APPROVAL ISSUER: ENGINEERING: PRODUCTION/MATERIAL: QA APPROVAL: REV 2 DATE BAS BAS WRC

INSTALLATION INSTRUCTIONS

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

MANUAL INSTALLATION. Venturi FX. VFX Series. v100 Issue Date: 11/22/ Price Industries Limited. All rights reserved.

½ DODGE CUMMINS

Key Installation Points. Table of Contents

READ INSTRUCTIONS THOROUGHLY BEFORE OPERATING TC-6 TC-15 TC Fax

ARC Welder Assembly & Operating Instructions

LED LINEAR INSTALLATION GUIDE RED 20L VER /13/

Inverting Fault Circuit Breaker Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives VAC and VAC

Approx. Net Frame Product Input Voltage Output Voltage kva Height (in) Width (in) Depth (in) Weight (Lbs.) Size Number

740G Double Disc Check. Valve. Operation / Maintenance Manual. General Information 2. Installation/Operation 3

Technical Installation Manual

APOLLO Model # - F-12013, F-22013, D-50115, D-50215, D-50415, D-50615, D-50815, D Apollo Series- Instruction Manual V.3

Instructions for Field Retrofit of a Model 98 Temperature Controller in place of a Model 85 Temperature Controller

PERFORMANCE EXHAUST INSTALLATION INSTRUCTIONS. PART NUMBER: D or D BLK APPLICATION: 2019 BMW F90 M5

Introduction. Pressed Shaft Flowmeter. Flowmeter Service Kits. Disassembly. Idler Shaft Removal

LS Series. Remix Shaft Installation Instructions REQUIRED TOOLS PARTS WORK SAFELY! PREPARATION/SAFETY PROCEDURES

CONTENTS FIGURES GETTING STARTED 1 1 PARTS FOR 1E SERIES 2 1. E Series Service Manual

"Engineered to Ride, Built to Last "

TABLE OF CONTENTS SPECIFICATIONS 3 INSTALLATION 4. Direct Mount 4. Ducted Installations 5. Installing Plenum 5. Machine Mount Stand 5.

Rosemount 285 Annubar Pak-Lok Assembly

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

L/6.7L DODGE CUMMINS

BD Dual Transmission Cooler Dodge (68RFE, 518, 47RH, 47RE & 48RE) Ford (5R110) & Chevy (Allison 1000) Transmissions

ROTON CONTINUOUS GEARED HINGES TABLE OF CONTENTS. L Length Specifications B Bearing at Top...4 Bearing on Top...4 Bearing Replacement Kit...

AquaPure Ei TM Series Replacement Kits

INSTALLATION GUIDE INSTALLATION GUIDE

"Engineered to Ride, Built to Last "

Crescent Flush Manifold FOR LIQUID LAUNDRY SUPPLY SYSTEMS

42 WATT LED TRIPLE BEAM WORKLIGHT

Luminous Patterns Panels

MODEL 22040, REMOTE CONTROL STAINLESS STEEL OR CHROME SPOT/FLOOD LIGHT INSTALLATION AND OPERATION INSTRUCTIONS IMPORTANT!

ENC-560 Autosampler Enclosure

VELOCICALC Air Velocity Meter

Cetra. Ceiling Power Entry Installation (AEC1, AEC14, or AEC16)

DCA400 Series Generator

INSTALLATION AND OPERATION INSTRUCTIONS

FILTER TESTING FOR AIR FILTER AND MEDIA EFFICIENCY MEASUREMENT

INSTALLATION INSTRUCTIONS For Light*Waves Flex II Kit with 300-Watt remote transformer

Installation, Care and Maintenance Instructions. Optiflush OP1 Battery and OP2 Mains Versions

Installation Instructions

HS5000 INSTALLATION GUIDE

Concealite Life Safety Products Model: R4000 Series (120/277 VAC Powered R4000 Remote Fixtures) Save These Instructions

Prodigy HDLV Manual System Installation Instructions

Installation Instructions

Assembly of kick TM Utility Poles

Installation, Operation and Maintenance Manual

ch2200 ch2300 mt3 osprey pro-trim single s twin s sl-3 INSTALLATION INSTRUCTIONS AND OWNERS MANUAL CH2200ENC SERIES SIDE MOUNT HYBRID ENGINE CONTROL

POLY TIP-DOWN WINDSHIELD KIT

CoolWave 2 Transformer T3 and Wire Harness Upgrade Kit

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

Extra Heavy Duty Modular Belts 2508 & 2630 Series

1 Match Blind to Window. Sivoia QED Installation Instructions. In-Line Coupled Roller Blind Addendum 1.1

OBSOLETE. RA-16 Rotary Atomizer Upgrade Kit. Instruction Sheet P/N A. 1. Introduction. 2. Disassembly

INSTRUCTION MANUAL MODEL # NOTE : This charger is designed for vehicles with dual batteries and negative ground.

ADVANCE ADAPTERS INC. P/N: JEEP TJ & (XJ 84-01) ATLAS 4 SPEED CABLE SHIFTER units built after 5/1/12

Transcription:

MODEL 8630 PRESSURA ROOM PRESSURE MONITOR INSTALLATION INSTRUCTIONS WARNING: The Model 8630 Room Pressure Monitor must be wired to 24 VAC only. Wiring the unit to 110 VAC will cause serious damage to the unit and void the warranty. The pressure sensor must be mounted through the wall between the controlled space (isolation room) and referenced space (ante room / hallway). These installation instructions guide the installer through the installation of the TSI Model 8630 PRESSURA Room Pressure Monitor. Please read these instructions thoroughly before beginning installation. This product is classified by Underwriters Laboratories, Inc. for use in through-penetration firestop systems. See UL fire resistance directory. Component List Part Number Qty Description 800243 1 Pressure sensor 800248 1 Sensor cable 800244 1 8630-SM Room pressure monitor or 800245 1 8630-PM Room pressure monitor 800420 1 Transformer 800414 1 Transformer cable 1901057 2 Intumescent ring 2923020 1 Fire sealant Figure 1: Typical Installation TSI and TSI logo are registered trademarks of TSI Incorporated. PresSura is a trademark of TSI Incorporated.

Pressure Sensor Installation Figure 2: Pressure Sensor Orientation and Mounting Template WARNING: 800243 pressure sensor must be mounted through the wall between the controlled space (isolation room) and referenced space (hallway), exactly as shown in Figure 2 and 3. 1. Determine pressure sensor location (Figures 1, 2 and 3). Pressure sensor typically mounts in the reference space, and the dummy housing mounts in the isolation room. Note: Pressure sensor is not symmetrical. If sensor is to be centered over hallway door, measure one inch to the left of center for 2¼ hole. Dummy sensor will be 2 off center on other side of wall. 2. The pressure sensor must be orientated on the wall as shown in Figure 2. Looking at the mounted sensor, sensor hole is on the left (2¼ ) and wire hole is on the right. 3. Drill a 2¼-inch hole through each side of the wall to accept the sensor tube. 4. Drill a 7/8-inch hole on the side of the wall that the pressure sensor will be mounted. This hole is for the sixconductor sensor cable. Refer to Figure 2 for a hole mounting pattern. 5. Slide sensor cover to right and remove screw that holds the sensor base to the pressure sensor (Figure 2). Remove pressure sensor and store in a safe place. -2-

6. From the side of the wall the sensor will be mounted, slide the sensor tube through the wall. Mark the tube where it is flush with wall. Remove sensor tube and cut tube 1/8 inch shorter than flush marking. Note: If 12 sensor tube needs to be extended, use same size or larger diameter tube. Drill out ½ sensor hole in dummy case to match ID of tube extension. 7. From the side of the wall the sensor will be mounted, slide the sensor tube through the wall. Slide the dummy base over the end of the tube. Screw the pressure sensor base and dummy base to the wall (Figure 3). 8. Wire the pressure sensor per Figure 7. Run sensor cable to the room pressure monitor 4 x 4 electrical rough-in box. 9. Insert fire protection sealant (provided) into 7/8 wire hole to seal. 10. Install and screw the pressure sensor and dummy cover onto the bases. Slide covers to the left to hide the sensor. Finished installation should look as shown in Figure 4. WARNING: Do not touch the sensor element in the pressure sensor. Do not run wires through the air passage. Doing so will damage the sensing element. Figure 3: Cutaway View of Mounted Pressure Sensor Figure 4: Pressure Sensor Mounting -3-

Transformer Installation WARNING Make sure no power is applied until all wiring is complete. Figure 5: Transformer Installation Follow all applicable electrical codes, and have qualified personnel install the transformer. Note: Each system must be installed with supplied transformer. If TSI transformer is discarded and a central transformer is installed, a separate isolation transformer must be installed in line between the TSI system and central transformer. 1. Mount a standard 4" x 4" x 1½" electrical box at a convenient location within 20 feet of pressure monitor. 2. Run 115 Volt, single phase, 60 hertz line voltage (115 VAC) to electrical box. Follow all applicable electrical codes. 3. Connect 115 VAC line voltage HOT wire to BLACK wire on transformer and NEUTRAL wire to WHITE wire on transformer (Figure 5). 4. Connect the RED wire on 800414 transformer cable to either YELLOW wire on the transformer and the BLACK wire to the remaining YELLOW wire. 5. Screw the transformer to the electrical box. 6. Run transformer cable from the transformer electrical box to the pressure monitor. Have at least 8 inches of cable coming out of the pressure monitor rough in electrical box before trimming cable to length. -4-

Pressure Monitor Installation Pressure Monitor Rough-in 1. Select the mounting location of the pressure monitor. The construction plans normally show the mounting location. If no location is specified, then the unit is typically installed as shown in Figure 1. Alternate mounting locations are nurse s station, other staff areas, etc. 2. Install a standard double gang electrical box (4 x 4 ). 3. Slide the pressure monitor cover to the right and remove three screws holding the electronics to the base (Figure 6). Remove base. 4. Install the base to the 4 x 4 electrical box. The base s THIS SIDE UP arrow must be pointing towards the ceiling. Note: Two screws are hidden behind the cover when full open. The cover will slide to the right approximately 2 inches until a stop is hit. Pull cover to completely remove from electronics and expose the screws. Figure 6: Pressure Monitor Mounting Pressure Monitor Wiring WARNING: Do not connect more than 24 VAC to any terminal. Do not apply voltage to the RS-485 output, analog output, or control output. Severe damage may occur to the unit if voltage is applied. 1. Remove the connectors from the back of the pressure monitor. 2. Refer to the wiring diagram (Figure 7) for proper wiring installation. 3. If additional options need to be wired, refer to building prints for proper wiring diagram. 4. Plug the connectors back into the pressure monitor. 5. Carefully push the wires into the electrical box and mount the pressure monitor. Install three screws to hold pressure monitor firmly to base. Install cover and slide left to hide display. -5-

Warning: Monitor must be wired exactly as wire diagram shows. Making modifications to the wiring may severely damage the unit. Figure 7: Wiring Diagram If you need assistance installing the system, call TSI at (800) 874-2811. TSI Incorporated Visit our website www.tsi.com for more information. USA Tel: +1 800 874 2811 UK Tel: +44 149 4 459200 France Tel: +33 491 11 87 64 Germany Tel: +49 241 523030 India Tel: +91 80 67877200 China Tel: +86 10 8251 6588 Singapore Tel: +65 6595 6388 P/N 1980244 Rev. D 2013 TSI Incorporated Printed in U.S.A.