HYDROMATIC HE8/HE12/HE20/HE25/ HE30/HE35/HE50 HIGH HEAD FILTERED EFFLUENT

Similar documents
HYDROMATIC SK75/100 SUBMERSIBLE SEWAGE EJECTOR

HYDROMATIC SPX50/SPX50H EXPLOSION PROOF, SEWAGE EJECTOR

HYDROMATIC SPD50H/100H SUBMERSIBLE HIGH HEAD, DOUBLE SEAL EFFLUENT

HYDROMATIC SKHS SERIES SUBMERSIBLE NON-CLOG, SEWAGE EJECTOR

SPD50H/100H. Performance Data SPD100H SPD50H. Wholesale Products Page: Section: Performance Data Dated: April 2002 Supersedes: January 2001

SKV40. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 2" Solids: 2" GPM: TDH:

SKHS SERIES 2 HP 1-1/2 HP 1 HP 1/2 HP CAPACITY-U.S. G.P.M.

Pump Specifications 250 Series Submersible Sump / Effluent Pump

Pump Specifications. LE50 Series ½ HP Submersible Sewage Pump

Pump Specifications FL50 Series 1/2 hp Submersible Effluent Pump

Pump Specifications 290 Series 3/4 hp Submersible Effluent Pump

Pump Specifications 280 Series 1/2 hp Submersible Effluent Pump

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump

Pump Specifications LE40 Series 4/10 HP Submersible Sewage Pump Pump

Pump Specifications LE100-Series 1HP Submersible Sewage Pump

Pump Specifications 405 Series Commercial Drain Pump (High-Temp)

Pump Specifications FL60/FLH60 Series 6/10 hp Submersible Effluent Pump

NOTE: LEH100-Series high-head pumps require a minimum application of 15' head. Do not use pump in this area use a smaller pump.

OIL SMART PLUG AND PLAY SYSTEM, Model #OSS-100

MYERS 3MW VERTICAL DISCHARGE WASTEWATER PUMPS. Sewage, high-capacity sump, effluent

Pump Specifications FL150 Series Submersible Effluent Pump

Pump Specifications FL100 Series Submersible Effluent Pump

Pump Specifications. ELV Series Submersible Sump Pump with OilTector Control. ELV250 1/3 hp ELV280 1/2 hp ELV290 3/4 hp

XFL70 FLOW RATE (LPM) Flow Rate (GPM)

XLE50 FLOW RATE (LPM) Flow Rate (GPM)

Pump Specifications. Omnivore 2HP Submersible Grinder Pumps LSG200-SERIES (SINGLE STAGE) LSGX200-SERIES (TWO STAGE)

LITERS PER MINUTE TOTAL HEAD IN FEET TOTAL HEAD IN METERS GALLONS PER MINUTE

Pump Specifications. D3648LSG, D3648LSGX Series Omnivore 2HP Duplex Grinder Packages LITERS PER SECOND

MYERS 4VCDP. 4" Solids Handling

Technical Data Sheet PF Series 4" (100 mm) Submersible Effluent Pumps. 1 8-inch (3-mm) bypass orifice (patent pending) to ensure flow

LITERS PER MINUTE GALLONS PER MINUTE

MYERS Predator Plus Series 4" Submersible Pumps

ST.E.P. Plus D Series 4" multi-stage submersible effluent pumps

PF Series 60-Hz, 4-inch (100-mm) Submersible Effluent Pumps

MYERS MODELS 4R AND 4RX

Pump Installation and Service Manual HRS Hydromatic Retractable System

Berkeley 8T-550 Submersible Turbine

MYERS S Series 4" Submersible Pumps

MYERS MODELS 4V AND 4VX

SPC-PANEL Simplex, Single Phase Pump Control Panel

MYERS MODELS 4RC AND 4RCX

MYERS MODELS 4VC & 4VCX

4" multi-stage submersible effluent pumps

MYERS MODELS 6VC & 6VCX

SHEF30 Submersible Sump/ Effluent Pump

SPECIFICATIONS EFFLUENT/SUMP DUPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

SKHS Series Submersible High Head Sewage Ejector Available Horsepower: 1/2, 1, 1-1/2, 2

Installation and Service Manual OSP50/OSP50AB Submersible Effluent Pumps

MODELS HPGFX/HPGHX & HPGFHX/HPGHHX

SP40 Submersible Sewage Ejector Pump

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

SPECIFICATIONS ULTIMAX SUB-SURFACE DIRECTIONAL AERATION SYSTEM

Submittal Data 3450 RPM 60 Hertz JOB or CUSTOMER:

SPECIFICATIONS OXYMAX SUB-SURFACE AERATION SYSTEM

KW Submersible, Single-Vane Impeller

SPECIFICATIONS Power supply required...see Motor and Cord Specifications chart below Motor duty...intermittent Discharge Adapter...

SAE Engine Mount. Selection For Pumping Application. Matching Pump End To Engine. Type B Centrifugal Pumps Close coupled pump ends.

Product Numbering System Typical Specifi cations, Models 4AC, 4AE, 6AC, 6AE, 8AC Pump Assembly, Types AC & AE

S4HVX Submersible Pump with Explosion-Proof Motor End (Class I, Division 1, Groups C & D): FM For use with product built with USEM motor.

HYDROMATIC. G1X200/G1LX200 Explosion Proof Submersible Grinder Pumps (Class I, Division 1, Groups C & D): FM. Pump Installation and Service Manual

Complete Grinder Package Offering

SPECIFICATIONS EFFLUENT/SUMP SIMPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

SIMPLEX, SINGLE PHASE PUMP CONTROL PANEL Model SPC-PANEL Pump Controls for 2 HP Grinder Pumps

MODEL SPC-PANEL. Pump Controls for 2 HP Grinder Pumps

Pump Installation and Service Manual SK75/100 Submersible Sewage Ejector Pumps

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

4" Submersible Motors XE-SERIES

HV200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

4" Submersible Motors

Installation, Operation & Parts Manual BV40 Submersible Sewage Ejector Pump

Berkeley Cast Iron Impeller B6ZPL ELECTRIC MOTOR DRIVE. Flanged Case, Packing Construction. Table I. Table II

Pump Installation and Service Manual SP40 Submersible Sewage Ejector Pump

Pump Installation and Service Manual JB-1 System Sewage Ejector Pump Package

Boand Arena Septic to Sewer Duplex Grinder Pumps (Commercial) Engineering Analysis

8400JF (240V Single Phase) Aerating Fountain Specifications

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

PENTEK XE-6. OWNER S MANUAL 6 Submersible Motors 293 WRIGHT STREET, DELAVAN, WI PH: PENTEK

CITY OF WEST PALM BEACH

Pump Installation and Service Manual SKV50 Submersible Sewage Ejector Pump

ME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt.

ECC ECC Flow(USGPM) Sump & Effluent De-watering Drainage. Phase Voltage Approx Weight (lbs)

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

SUBMERSIBLE SEWAGE PUMPS

Installation and Service Manual SK50 Submersible Sewage Ejector Pump

Precision-engineered, corrosionresistant

Pump Installation and Service Manual SHEF50/SHEF100 Submersible Effluent Pump

Series 6XSHD. Specifications: Series: 6XSHD 15-30HP, 1750RPM, 60Hz HP, 1150RPM, 60Hz. 21 Frame Driver 3" Spherical Solids Handling

Nothing Better Top-of-the-line 4 submersible pump is unequalled in the marketplace. Stainless Steel

Precision-engineered, corrosionresistant

4400JF (120V) Aerating Fountain Specifications

8VL and 8VLX. UÒ=pìÄãÉêëáÄäÉ=kçåJ`äçÖ=t~ëíÉï~íÉê=mìãé pí~åç~êç=eusif=~åç=bñéäçëáçåjmêççñ=eusiuf

KG(X)3. Grinder Pumps. 3HP High Flow Grinder Pump (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve. Total Head (FT) Capacity (GPM)

HYDR-O-RAIL SYSTEM. Pump Installation and Service Manual

GR NDER PUMPS. 505 Woodland Rd., Mt. Pocono, PA Phone: (570) Fax: (570)

MWH50 - MW200 Series ME50 - ME150 Series Submersible Sump, Effluent & Sewage Pumps

GR NDER PUMPS. Technical Catalog

Precision-engineered, corrosionresistant

Pump Installation and Service Manual SK60 Submersible Sewage Ejector Pump

KGX2-21. Grinder Pumps. 2HP Dual Seal Grinder Pump, External Start (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve

Transcription:

PERFORMANCE DATA Wholesale Products Page: 6650-1 RPM: 3450 Discharge: * Solids: ⅟₁₆ 8 GPM 500 3/4 HP 0 2 4 6 8 10 12 14 16 18 20 HP ¾ 1 12 GPM Voltage Pump Model HE8-51 HE8-52 HE8-72 HE8-12 25 GPM 0 0 5 10 15 20 25 30 35 40 45 50 30 GPM 120 80 40 1- HP Voltage 1 1 *Discharge Size 2" NPT Pump Model HE25-12 HE25-152 3/4 HP 0 5 10 15 20 25 30 35 40 45 50 35 GPM HP Voltage Pump Model HE30-51 1-150 *Discharge Size 2" NPT 0 2 4 6 8 10 12 14 16 18 20 HP ¾ 1 20 GPM 1-3/4 HP HP ¾ 1 1 Voltage Pump Model HE12-51 HE12-52 HE12-72 HE12-12 0 3 6 9 12 15 18 21 24 27 30 Voltage Pump Model HE20-51 HE20-52 HE20-72 HE20-12 HE20-152 50 0 5 10 15 20 25 30 35 40 45 50 50 GPM 500 HP Voltage Pump Model 1 HE35-12 1 HE35-152 1- *Discharge Size 2" NPT 0 10 20 30 40 50 60 70 80 90 HP Voltage Pump Model 1 HE50-152 The curves reflect maximum performance characteristics without exceeding full load (Nameplate) horsepower. All pumps have a service factor of 1.2. Operation is recommended in the bounded area with operational point within the curve limit. Performance curves are based on actual tests with clear water at 70 F. and 1280 feet site elevation. Conditions of Service: GPM: TDH:

DIMENSIONAL DATA Wholesale Products Page: 6650-2 A M C E D B A = Overall Pump Height B = Motor Height C = Intake Height D = Pump End Height E = Bypass Orifice Height M = Minimum Liquid Level Discharge = Discharge Size (NPT) MODEL A B C D E M DISCHARGE HE8-51 24-1/4 9-1/2 12 14-3/4 20-3/4 19-1/2 1-1/4 HE8-52 24-1/4 9-1/2 12 14-3/4 20-3/4 19-1/2 1-1/4 HE8-72 26 10-1/2 13 15-1/2 22-1/2 21 1-1/4 HE8-12 29-3/4 11-3/4 14-1/4 18 26-1/4 23 1-1/4 HE12-51 23-1/4 9-1/2 12 13-3/4 19-3/4 20 1-1/4 HE12-52 23-1/4 9-1/2 12 13-3/4 19-3/4 20 1-1/4 HE12-72 26-1/4 10-1/2 13 15-3/4 22-3/4 21-1/2 1-1/4 HE12-12 29 11-3/4 14-1/4 17-1/4 25-1/2 23-1/2 1-1/4 HE20-51 23-1/2 9-1/2 12 14 20 20 1-1/4 HE20-52 23-1/2 9-1/2 12 14 20 20 1-1/4 HE20-72 25-1/2 10-1/2 13 15 22 22 1-1/4 HE20-12 27-1/2 11-3/4 14-1/4 15-3/4 24 26 1-1/4 HE20-152 34-1/4 15-1/4 17-3/4 19 30-3/4 27 1-1/4 HE30-51 23-1/2 9-1/2 12 14 20-1/2 20 1-1/4 HE25-12 29-3/4 11-3/4 14-1/4 18 28 27 2 HE25-152 36-1/4 15-1/4 17-3/4 21 34-1/2 29 2 HE35-12 26-1/4 11-3/4 14-1/4 14-1/2 24-1/2 27 2 HE35-152 33-3/4 15-1/4 17-3/4 18-1/2 32 29 2 HE50-152 34 15-1/4 17-3/4 21 32-1/4 29 2 All dimensions in inches. Metric for international use. Component dimensions may vary ± 1/8 inch. Dimensional data not for construction purpose unless certified. Dimensions and weights are approximate. On/Off level adjustable. We reserve the right to make revisions to our product (s) and the product (s) specifications without notice.

ELECTRICAL DATA Wholesale Products Page: 6650-3 MODEL: R.P.M. 3450 MOTOR PROTECTION BUILT IN OVERLOAD AND SURGE PROTECTION HP VOLTAGE PHASE NEC CODE SERVICE FACTOR FULL LOAD AMPS 10.5 1/2 6 3/4 1-1 8 1 9.8 1-1/2 13.1

TECHNICAL DATA Wholesale Products Page: 6650-4 MODEL: Physical Data DISCHARGE SIZE (NPT) (1 ¼ on 8, 12, 20, and 30 GPM pumps) (2 on 25 and 35 GPM pumps) SOLIDS SIZE ⅟₁₆ IMPELLER TYPE - CABLE LENGTH 20 STANDARD 30 OPTIONAL PAINT - Temperature MAXIMUM LIQUID 122 F MAXIMUM STATOR - OIL FLASH POINT - Technical Data POWER CORD TYPE SJTW, STW-A MOTOR HOUSING STAINLESS STEEL CASING STAINLESS STEEL IMPELLER THERMOPLASTIC MOTOR SHAFT - HARDWARE STAINLESS STEEL O RINGS - MATERIALS OF CONSTRUCTION MECHANICAL SEALS Standard: - UPPER BEARING - LOWER BEARING -

SPECIFICATION DATA Wholesale Products Page: 6650-5 MODEL: 1.01 GENERAL Contractor shall furnish all labor, materials, equipment and incidentals required to provide (Qty.) submersible centrifugal effluent pump(s) as specified herein. The pump models covered in this specification are the HE8, HE12, HE20, HE25, HE30, HE35 and HE50. The pump furnished for this application shall be MODEL as manufactured by Hydromatic Pumps. 2.01 DESIGN CONDITIONS Each pump shall be rated H.P., volts, phase, hertz and operate at RPM. 3.01 OPERATING CONDITIONS The pump shall deliver U.S. GPM/LPS at feet/meters TDH, and handle a inch solid. The curve submitted for approval shall state, in addition to head and capacity performance, solid handling capability, amp rating, and design impeller diameter. 4.01 CONSTRUCTION Each pump shall be of the sealed submersible type, incorporating features normally found in pumps furnished for the residential market. These features include: 1. The seal housing for the HE8, HE12, HE20, HE25, HE30, HE35 and HE50 is corrosion resistant stainless steel. 2. The pump inlet shall be double screened. 3. All power cords shall be water resistant UL or CSA approved. 5.01 MOTOR AND SHAFT The stator, rotor and bearings shall be mounted in a sealed submersible type housing. Single phase motors shall be split phase or capacitor start with centrifugal switch. Three phase motors shall be Polyphase. Full Load and Locked Rotor Amps as well as Start and Run winding resistance shall be tabulated for each pump. 6.01 IMPELLER The Impeller shall be thermoplastic construction. 7.01 MANUAL CONTROL The Single Phase pumps are not supplied with any type of automatic control. 8.01 TESTING All pumps shall be individually tested to include the following: 1. The pump and power cord shall be visually inspected for imperfections, cuts or nicks. 2. The pump shall have a ground continuity check and the motor chamber shall be Hi-potted to test for moisture content and/or insulation defects.

SPECIFICATION DATA Wholesale Products Page: 6650-6 THIS PAGE LEFT INTENTIONALLY BLANK USA CANADA 293 Wright Street, Delavan, WI 53 WWW.HYDROMATIC.COM 269 Trillium Drive, Kitchener, Ontario, Canada N2G 4W5 PH: 888-957-8677 ORDERS FAX: 800-426-9446 PH: 519-896-2163 ORDERS FAX: 519-896-6337 Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice. 2013 Pentair Ltd. All Rights Reserved. W-01-260 (03/25/13)