Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Similar documents
Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

CAC SERIES 12-1/2 Thru 20 Ton

6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant. Nominal Capacity BTUH

UMXCA/UMXCBA ECVA/ECVBA

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

Concealed Ducted Split Series R22

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

CHP

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

LUI / LUO. Condensing Units

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

D M S 760 C01 A A 1 1

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT

Stylus 4G. Mini Split Air Conditioners. Stylus 4G Series Convertible Type 12,000-60,000 Btu/h MCX / MWX SERIES 50 Hz R22 / R410a

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

AHN 064 to 304 EHN/CHN 064 to 304

Package Air Conditioners

CHP SERIES FEATURES. High Pressure Control Three Phase Models. Low Ambient Fan Cycle Control Three Phase Models

Section 5 AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH

NOMENCLATURE WATER COOLED PACKAGE UNITS GENERAL DESCRIPTION. Cleanable Shell and Tube Condenser. Scroll Compressor(s)

10+ SEER - AIR CONDITIONER

TRI-CAPACITY PACKAGE UNIT

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

14.5 SEER HEAT PUMPS. Featuring Industry Standard R-410A Refrigerant TZPL SERIES. Features Coils constructed with copper tubing and enhanced aluminum

HCH6. Product Specifications

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

DESCRIPTION FEATURES

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

13 SEER CONDENSING UNITS

WATER SOURCE HEAT PUMPS

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

MEDIUM SILHOUETTE UNIT COOLERS AIR AND ELECTRIC DEFROST MODELS

N2AE - 50 Hz PRODUCT SPECIFICATIONS

R4H4. Product Specifications

14.5 SEER VALUE SERIES CONDENSING UNITS

Enhanced Air Conditioning

Air-Cooled Liquid Chiller with integrated hydraulic module

PCB COMMERCIAL SERIES

MODEL: DCT 35 INV-Si DCT 50 INV-Si DCT 70 INV-Si DCT 100 INV-Si DCT 140 INV-Si DCT 170 INV-Si

PACKAGE AIR CONDITIONERS

CS Series Condensing Units

GSZ13. Energy-Efficient Split System Heat Pump 1½ to 5 Tons. Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h

SPLIT SYSTEM HEAT PUMPS. ERA Series 10 SEER Single and Three Phase TECHNICAL SPECIFICATIONS

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

CGA CXA VGA VXA CG-PRC006-E4

N4A6. Product Specifications

GUIDE SPECIFICATIONS CE Series Two Stage R-410A

1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

19,1 261,0 kw COOLING 23,7 333,0 kw HEATING

FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E

O5DMA-NRG O5DMA-NRG. Self-Contained Multi-Deck Merchandiser 4', 6', 8' & 12' (Dairy / Deli / Beverage / Produce) SHIPPING WEIGHT GENERAL NOTES

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw

N4A4 C. Product Specifications

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

GUIDE SPECIFICATIONS. ES Series R-410A

Product Data PH13NA PH13PA FEATURES AND BENEFITS. 13SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES:

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE

HEAT PUMPS UPKB- SERIES. Seven Models

Q5RD Series Single Packaged Heat Pump, Single Phase

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Heat Exchangers. Evaporator Catalogue

R2H3. Product Specifications 3 PHASE HEAT PUMP COMPONENT. For Use With R 22 Refrigerant. 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz

DRAFT. Technical Data OPA Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

ROOF TOP PACKAGE UNITS

T-Class Split System Units R-410A - 50 HZ

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum

50JZ 7 to 14 kw ( ) STANDARD EFFICIENCY. SINGLE-PACKAGE 50 Hz. ELECTRIC HEAT PUMP UNITS with optional ELECTRIC HEAT

^áêëçåâ=ìåáí=åççäéêë=qvoj^ pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Low Static Pressure Duct(V shape evaporator)

PHR5. Product Specifications

PACKAGE HEAT PUMP UNITS

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Low Static Pressure Duct (V shape evaporator)

R4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

10+ SEER - AIR CONDITIONER

R22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz]

ZHA/ZHB SERIES WARNING

Next-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

CSA6. Product Specifications. SoftSound SXC 2600

14.5 SEER HEAT PUMPS. Featuring New Industry Standard R-410A Refrigerant TZPL SERIES

Transcription:

R410a Refrigerant SHS1 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 2 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 3 40 4 17 14.0 9.1 9.8 13.2 8.8 9.0 12. 8. 12.9 11.7 8. 13.3 18 14.7 8.1 9.0 13.7 7.8 13. 13.0 7. 14.0 12.2 7.0 14.3 19 1.0 7.1 7.8 14.4.8 14.8 13.7. 1.0 12.7.0 1.3 20 1.0.0.7 1.0.7 1.8 14.3. 1.0 13.3.0 1.3 17 14.0 11.1 12.3 13.3 11.0 12. 12.8 10. 13.0 11.7 10.2 13.1 18 14.4 9.1 13.4 13.7 10.8 13.7 13.4 9. 14.0 12.2 9.0 14.1 19 1.0 9.1 1.4 14.3 9.8 14.7 13. 8. 1.0 12.8 8.1 1.2 20 1.7 8.0 1.4 14.7 8.8 1.8 14.4 7. 1.0 13.3 7.3 1.2 21 1.3 7.0 1.4 1.4 7.7 1.8 1.0.4 17.0 14.0.0 17.1 17 14.2 12.8 12.4 13. 12.7 12.4 13.0 12.2 12.8 12 11.7 13.0 18 14. 12. 13.4 14.0 12. 13.7 13.3 11.7 13.9 12.2 11.0 14.1 19 1.0 12.0 14.4 14.3 11.9 14.7 13. 10. 1.0 12.8 10.1 1.2 20 1. 11.3 1.4 14.9 10.8 1.7 14.2 9. 1.0 13.7 8.8 1.1 21 1.3 10.7 1. 1. 10.0 17.3 1.0 8.2 17.0 14.0 7.3 17.1 17 14. 14.1 12.0 14.0 13.8 12.4 13.3 12.8 12. 12. 12. 12.8 18 14.7 13.8 13.2 14.1 13. 13. 13.4 11.7 13.9 12. 12. 13.9 19 1.1 13. 14.3 14.3 13.0 14.8 13.7 10.9 1.0 12.7 12.1 1.2 20 1. 12.7 1.4 1.0 11. 1.3 14.2 10. 1.0 13.4 9.7 1.2 21 1.3 11. 1. 1.8 10.7 1.0 1.0 9.4 17.0 14.0 8. 17.2 17 1.0 14.3 12.0 14.4 14.2 12.0 14.0 14.0 12.1 13.2 13.2 12. 18 1.1 14.0 13.0 14. 13.9 13.3 14.0 14.0 13. 13.2 13.2 14.0 19 1.2 13.7 14.4 14. 13. 1.0 14.0 14.0 1.0 13.2 13.2 1.2 20 1.7 13.1 1. 14.9 13.0 1.1 14.4 13. 1.0 13. 11.4 1.3 21 1.3 12.7 1. 1.8 12.7 17.0 1.0 12.0 17.0 14.0 9.9 17.3 17 1. 1.2 11. 1.0 1.0 12.0 14. 14. 13. 14.0 14.0 12. 18 1.7 1.1 12.9 1.0 1.0 13.0 14. 14. 14.0 14.1 14.0 13.9 19 1.7 14.9 13.9 1.0 1.0 1.4 14. 14. 1.0 14.2 14.1 1.0 20 1.8 14.8 1.4 1.0 1.0 1. 14.8 14.3 1.9 14.2 13.9 1.1 21 1.3 14. 1.4 1.8 14. 1.7 1.4 14.0 17.1 14.2 13. 17.4 Capacity multipliers should be applied to the above capacities to adjust for reduced or increased air flow.

Technical Specification SHS1 Split Ducted Model Indoor Unit Model Number SHS1N Nominal Evaporator Air Flow (l/s) 80 Outdoor Unit Model Number SHS1W Number of Compressors 1 Total Cooling Capacity (kw)* 14.3 Power Requirements (Volt / Phase) 41 / 3 Sensible Cooling Capacity (kw)* 13 Normal Max. Current (Amps / Phase) 12.1 Heating Capacity (kw)** 14.2 *Entering air @ 27/19 and ambient 3 ** Entering air @ 21 DB and 7 ambient Air Quantity Multiplying Factors % Rated Air Quantity-Nominal 80 l/s Capacity 80 90 100 110 120 Total 0.9 0.98 1.00 1.02 1.04 Sensible 0.89 0.9 1.00 1.0 1.09 Heating Performance Data Outdoor Coil Entering DB temp 0 4 8 12 18 Heating Capacity kw 11 13 1 1.1 18.2 % Rated Air Quality Heating Performance Correction Multiplier Return Air Temp Multiplier Outdoor Air Temp Approx. Defrost Factor 80 0.93 1 1.0 0 0.80 90 0.97 18 1.03 2 0.78 100 1.00 21 1.00 4 0.7 110 1.03 24 0.97 7 0.87 120 1.0 27 0.9 8 1.00 Compressor Number Per Unit 1 Scroll RPM (Nom) 2900 Normal Max. Current (Amps / Phase) 8. Locked Rotor Current (Amps / Phase).8 Displacement (m 3 /h) 17. Electrical Controls and Safeties High Pressure Switch (Setting kpa) 2800 Defrost Low Pressure Switch (Setting kpa) 100 Initiation Temperature () -4 Indoor Fan Overload Internal Termination Temperature () 10 Outdoor Fan Overload Internal Min. Period Between De-Ice (min) 33 Compressor Delay Timer 300 sec Max. De-Ice Period (min) 4 Standard Features Manual reset high pressure and auto reset low pressure cutouts Thermal overload protection on all motors Compressor crankcase heater Limit start timer (anti short cycling) Suction line accumulator Automatic de-ice system Thermally insulated indoor unit Evaporator Copper Tube / Aluminium Fins Face Area (m) 0.3 Air Quantity (l/s) 80 Evaporator (Indoor) Number of Fans 2 Centrifugal Drive Direct Motor Voltage / Phase / Frequency 240 / 1 / 0 Motor (kw) Standard 2 0.37 Max. Fan Speed (rpm) 120 Electrical Power Requirements 3 Phase / 41V / 0Hz Normal Max. Current (Amps / Phase) 12.1 Condenser Copper Tube / Aluminium Fins Face Area 1 Condenser (Outdoor) Number of Fans 2 Axial Drive Direct Enclosed Motor Watts / rpm 2 240 / 900 Motor Voltage / Phase / Frequency 240 / 1 / 0 Refrigerant System Refrigerant R410a Charge (kg) 4. Line Size (mm) Liquid 0 10 metres 13 Gas 0 10 metres 19 Liquid 10 20 metres Gas 10 20 metres Service Connections Rotor Lock Valve Expansion Control in outdoor unit Capillary Page 2

340 Refrigerant Connections 80 Electrical Connections MODEL: DRAWING NO.: ISSUE: SHS1WBb2 A4 SHEET SIZE: Li Meifen Zhang Jingfei APPROVED Q.A.: APPROVED ENG.: TITLE:Split System Air Cooled Heat Pump Unit SHS TYPE Chen Cheng 7th Jan.10 DRAWN BY: DATE: For units with R410a/R407C/R22 OUTDOOR UNIT INSTALLED WEIGHT 10 kg 124 90 Page 3

30 10 100 Electrical Connections 1320 110 Drain Connections ZG3/4" 200 1400 80 MODEL: DRAWING NO.: ISSUE: SHS1NBb2 A4 SHEET SIZE: Li Meifen Zhang Jingfei APPROVED Q.A.: APPROVED ENG.: TITLE:Split System Air Cooled Heat Pump Unit SHS TYPE Chen Cheng 7th Jan.10 DRAWN BY: DATE: For units with R410a/R407C/R22 INDOOR UNIT INSTALLED WEIGHT 80kg 70 Evaporator Fan : 2 * KDF2.2B/190 Evaporator Motor: YSK-370W-4 10 102 Access Panel 48 320 28 420 10 Refrigerant Connections 20 Page 4

1 3 2 4 9 10 4 4 4 21 22 A1 A2 A1 A2 A B A B A B 1 3 13 14 1 2 3 A1 A2 11 14 A2 A1 M1 B1 Page

Page

Page 7