Application of AC Three-Phase Induction Motor of Wound Rotor AEL-ACWRA

Similar documents
Application of AC Three-Phase Induction Motor of Squirrel Cage AEL-ACINA

Application of AC Dahlander Three-Phase Induction Motor AEL-ACDHA

DC Brushless Motor Application AEL-DCBRA

INTRODUCTION. AC motor operations, most widely used motor is three phase induction motor. This type of motor does not require any starting device

Transparent and Functional Motors Application AEL-FTM

Motor-Generator and Transformer Construction Application AEL-MGTC

MGI. Gyroscope PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION. Engineering and Technical Teaching Equipment

Wind Energy Unit EEE. Engineering and Technical Teaching Equipment PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION. Electronic console

Biodiesel Process Unit EBDB

Basic Unit of Mechanical Drive Systems MDSU. Engineering and Technical Teaching Equipment INTRODUCTION GENERAL DESCRIPTION

Assembly and Maintenance of Pumps AMP

Energy Power Plants Trainer AEL-EPP

AEL-4. Advanced Electrical Laboratories (AEL-LABS): Electromechanical Constructions Lab. Engineering and Technical Teaching Equipment

Electrical Machines Lab

Photovoltaic Solar Energy Modular Trainers

Photovoltaic Solar Energy Modular Trainers

TECNEL. Computer Controlled Teaching Unit for the Study of Power Electronics. (Converters:DC/AC+AC/DC+DC/DC+AC/AC)

Screenshot of the computer data acquisition and calculations software INTRODUCTION

Final User Smart Grid Trainer AEL-FUSG

Hydraulic and Electro-Hydraulic Application AE-HD

Power Systems and Smart Grid Technology Lab

Fluid Friction in Pipes, with Hydraulics Bench (FME00) AFT

Photovoltaic Solar Energy Unit EESFB

Pneumatic and Electro-Pneumatic Application AE-NS INTRODUCTION

AEL-3. ELECTRICAL MACHINES LAB AEL-2. HOME AUTOMATION SYSTEMS LAB

Integrated Laboratory for Electrical Machines LIMEL

ES09 ELECTRICAL MACHINES TECHNICAL SPECIFICATIONS

Brake Test On Three Phase Induction Motor Lab Manual

WORK BENCHES FOR ELECTRIC INSTALLATIONS. index

ELECTRIC MACHINES EUROLAB 0.3 kw

BAIJI OIL TRAINING INSTITUTE ISO-9001:2008 DATE :1/4/2014 LABORATORY FOR THE ELECTRICAL SYSTEMS AND CONTROL OF OIL DRILLING RIGS $

2 kw Electromechanical Training Systems

Electrical Power Systems 2014/15

Open Chassis Star-Delta Starter User Guide

SWITCHGEAR. 4G cam switches

0.2 kw Electric Power Transmission Training System

8036-A0 Motor Drives Training System (Stand-Alone)

Load Test On 3 Phase Slip Ring Induction Motor Lab Manual

ICG Switchgear Price List 2009

The Wound-Rotor Induction Motor Part I

EXPERIMENT 2 THREE PHASE INDUCTION MOTOR, PART 1

Starting of Induction Motors

ELECTRIC MACHINES EUROLAB 0.3 kw

ELECTRIC MACHINES UNILAB 1 kw

Electrical Power Electric power electrical electric power Electric power electric electric

Industrial Wiring Training Systems

SQA Advanced Unit specification: general information

EMMS3 ELECTRICAL MACHINES MODULAR SYSTEM 300W

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Model ED 720 Drying and heating chambers Classic.Line with natural convection

Standby Amper VOLTAGE

RENEWABLE ENERGY TRAINER

Standby Amper VOLTAGE

Legal Name of the Customer (or, if an individual, individual's name): Name: Contact Person: Mailing Address: Physical Address: City: State: Zip Code:

Installation Manual for DC Injection Brake Units

UNC-Charlotte's Power Engineering Teaching lab

Training & Didactic Systems. Fundamentals of Electrical Engineering

SDS Enclosed Star-Delta Starter User Guide

Model ED 400 Drying and heating chambers Classic.Line with natural convection

Model ED 400 Drying and heating chambers Classic.Line with natural convection

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

HIGH POWER SOLENOID DRIVER 1

DEPARTMENT OF EI ELECTRICAL MACHINE ASSIGNMENT 1

TECHNICAL SPECIFICATION

Industrial Controls Training Systems

SPECIFICATIONS NB SKILLS TRADE 19 AUTOMATION AND CONTROL

SD Series Non-Fused Load Switches

Overview. Contents. Overview

825-P Modular Protection System for motors Specification Guide

Motor Drives Training System (Stand-Alone, 120 V Version) (8036-C0)

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

CONTACTOR, AC-3 15 KW/400 V, AC 110V 50HZ/120V 60HZ 3-POLE, SIZE S2, SCREW CONNECTION. General technical data: Main circuit: product brand name

IRT 4000 AT-S/M/L. Technical Manual. quality IN MOTION. quality IN MOTION

Subsidiaries: PORTUGAL POLAND GERMANY UK SINGAPORE UAE PANAMA DOMINICAN REPUBLIC ARGENTINA ANGOLA SOUTH AFRICA

Electrical Power & Machines Range

A Electric Power / Controls SMART GRID TECHNOLOGIES 0.2 kw

Development of Electrical Power System Simulator.

Installation & Operation Manual

ELECTRIC AND ELECTRONIC ACCESSORIES. motralec

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Demonstrate knowledge of electrical theory for Electrical Service Technician B

SP5 INSTALLATION AND SETUP MANUAL

Power Systems Trainer

Fachpraktikum Elektrische Maschinen. Experiments with a 400/ 690 V Squirrel Cage Induction Machine

PORTABLE CURRENT SOURCE FOR CIRCUIT BREAKER AND MOTOR OVERLOAD TESTING INSTRUCTION MANUAL PI-250B. Release 1.0 April 5, 2013

Electricity Course. Part B Course Outline

Three-Phase Motors and Drives

SECTION V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2

* With I-Option card only (C. T. connection) Basic connections with isolated contacts

Power Conversion System The Best Technology for your photovoltaic and storage system

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

STEP Motor Control Centers

GENERATOR DATA SEPTEMBER 29, 2015

Softstarters Softstarters

Asynchronous generators

Hybrid and Electric Vehicles

EDIBON SCADA System and PID Control included. 2 Control Interface Box. 1 TIUS. Base Service Unit. Cables and Accessories Manuals. TIPL.

SOLSTART Instruction Manual

Current Automation Catalogue

CI-TI Contactors and motor starters Types CI 61 - CI 98

Transcription:

Engineering and Technical Teaching Equipment Application of AC Three-Phase Induction Motor of Wound Rotor AEL-ACWRA INTRODUCTION The electric motors are devices capable of transforming electrical energy into mechanical energy. The three-phase induction motors with wound rotor are very used in industrial installations. The advantage of these machine is that starting can be reduced by using rotor resistances. In the starting moment several resistances are connected to the rotor. Once the motor is turning, the rotor is short circuited. ISO 9001: Quality Management (for Design, Manufacturing, Commercialization and After-sales service) European Union Certificate (total safety) 1 Certificates ISO 14001 and ECO- Management and Audit Scheme (environmental management) Certificate and Worlddidac Member

GENERAL DESCRIPTION The Application of AC Three-Phase Induction Motor of Wound Rotor, AEL-ACWRA, is designed for the study of the main operations performed in the industrial field with this three-phase induction motors with wound rotor. The student will understand the most important operations of these electrical machines faithfully by using commutators, timers and contactors. The AEL-ACWRA includes the following modules: N-ALI01. Industrial Main Power Supply. N-ARR12. Direct Starter. N-PUL48. 3 Double Chamber Push-Buttons. N-LAM02. Auxiliary Lamps. N-CON01. 3-pole Contactor (24 VAC). (4 units) N-REL30. Synchronization Relay. (3 units) N-ALI03. AC Auxiliary Power Supply. EMT8. Asynchronous three-phase motor with wound rotor. FLYW. Flywheel. N-TRANS03. Three-phase Autotransformer 400/230 VAC, 1KVA. Expansion learning software: In addition, Edibon provides expansion learning software (AEL-ACWRA/ICAI) to reinforce knowledge about this field. This software is formed by: ECM-SOF. EDIBON Classroom Manager (Instructor Software). ESL-SOF. EDIBON Student Labsoft (Student Software). Additional and recommended measurement instrumentation modules: - Digital Instrumentation: N-EALD. Network Analyzer Unit with Computer Data Acquisition. - Analog Instrumentation: N-MED10. AC Ammeter (0-5 A). N-MED22. AC Voltmeter (0-400 VAC). N-MED33. 3-Phase Balanced Wattmeter 440 V. N-MED31. 3-Phase Phasemeter 400V. N-MED39. 3-Phase Balanced Varmeter 440 V. If the Option A (modules mounted on rack) is chosen, the rack/s required will depend on the optional modules requested by the customer. The application AEL-ACWRA can be mounted on rack (option A) or on rail (option B): Option A: This application needs the following racks: N-RACK-A (2 units). Optionally the AEL-WBR. Electrical Workbench (Rack) can be supplied to place the rack/s. Option B: This application can be mounted on rail. Optionally the AEL-WBC. Electrical Workbench (Rail) can be supplied to mount the modules. 2

SPECIFICATIONS The application includes the following modules: N-ALI01. Industrial Power Supply. Supply voltage: 400 VAC, 3 PH+N+G. ON-OFF removable key. Output voltage connections: Three-Phase + Neutral: 400 VAC. Single-Phase: 230 VAC. Three-Phase supply hose with IP44 3PN+E 32A 400 V connecting plug. Differential magnetothermal, 4 poles, 25 A, 300 ma AC 6 KA. N-ALI01 N-ARR12. Direct Starter Module. Nominal voltage: 400 VAC. Maximum contacts current: 10 A. Two positions commutator (ON-OFF): 0: Open circuit. 1: Closed circuit. N-ARR12 N-PUL48. 3 Double Chamber Push-Buttons. Two independent chambers. Nominal voltage: 24 VAC. Three double chamber push-buttons (green and red). Contacts: Three Normally Open Contacts (NO) for green switch. Three Normally Close Contacts (NC) for red switch. Ground terminal. N-PUL48 N-LAM02. Auxiliary Lamps. Nominal voltage: 24 VAC. Three lamps (red, yellow and green). Ground terminal. N-CON01. 3-poles Contactor (24 VAC). (4 units). Nominal voltage for power contacts: 400 VAC. Nominal voltage for control contacts: 24 VAC. Nominal voltage for the control coil: 24 VAC. Contacts: One three-phase Normally Open Contact (NO) for power circuit. Three Normally Open Contacts (NO) for control circuit. Two Normally Close Contacts (NC) for control circuit. Ground terminal. N-LAM02 N-CON01 N-REL30. Synchronization Relay Module. (3 units). Nominal voltage for power contacts: 400 VAC. Nominal voltage for control contacts: 24 VAC. Nominal voltage for the control coil: 24 VAC. Contacts: One three-phase Normally Open Contact (NO) for power circuit. Three auxiliary contacts: One instantaneous Normally Open Contact (NO). One time Normally Open Contact (NO). One time Normally Close Contact (NC). Ground terminal. 3 N-REL30

N-ALI03. AC Auxiliary Power Supply. Supply voltage (Single-Phase): 230 VAC PH+N+G. Output voltage: Single-Phase 24 VAC/12 VAC. 24 VDC. 0-24 VDC through potentiometer. Specifications N-ALI03 EMT8. Asynchronous Three-Phase Motor with Wound Rotor. Nominal power: 300 W. Nominal voltage: 3x 230/400 VAC Δ/Y. Frequency: 50/60 Hz. Number of poles: 2. RPM: 2870 r.p.m. Nominal current: 1/ 0,5 A. EMT8 FLYW. Flywheel. Weight: 2 kg. Maximum recommended speed: 4000 r.p.m. Moment of inertia: 0,0025 kgm ². FLYW N-TRANS03. Three-Phase Autotransformer Module 400/230 VAC, 1KVA. Three-phase autotransformer. Nominal supply voltage: 400 VAC (3PH). Nominal output voltage: 3 x 230 VAC (3PH+N). Nominal power: 1 kva. Transformer connection: YY0. Start/stop commutator for instantaneous connection/disconnection of the grid transformer. Fuses: 3 x 5 A. N-TRANS03 Additional and recommended measurement instrumentation modules: N-EALD. Network Analyzer Unit with Computer Data Acquisition. ON-OFF switch. Supply voltage: 400 VAC. Input terminals: Input connection with the measurement point. Output terminals: Output connection with the measurement point. Digital outputs: Three digital outputs are used for pulses or alarms, or for combining both. RS-485 Communication port. Fuses: 3 x 10 A. Network Analyzer Display. It shows: Active, reactive and apparent power. Active, reactive and apparent energies. Lines and phase currents. Line and phase voltages. Frequencies. Power Factor. 4 N-EALD

N-MED10. AC Ammeter (0-5 A). Specifications Measurement range: 0-5 A. Terminals: Measurement Terminals. Ground Terminal. N-MED10 N-MED22. AC Voltmeter (0-400 VAC). Measurement range: 0-400 VAC. Terminals: Measurement Terminals. Ground Terminal. N-MED22 N-MED33. 3-Phase Wattmeter 440 V. Nominal voltage 440 VAC. Terminals: Measurement Terminals. Ground Terminal. N-MED33 N-MED31. 3-Phase Phasemeter 400 V. 3 phasemeter. 400 Vac. CAP 0.5-1-0.5 IND. Accuracy 1.5 % of 90º. N-MED31 50 or 60 Hz. N-MED39. 3-Phase Balanced Varmeter 440 V. 3 phase balanced varmeter. 440 VAC. Range: 0-300 Var. Scale 90º. N-MED39 Accuracy 1.5%. 50 or 60 Hz. All necessary cables to realize the practical exercises are included. Cables and Accessories, for normal operation. Manuals: This unit is supplied with the following manuals: Required Services, Assembly and Installation, Starting-up, Safety, Maintenance & Practices Manuals. 5

EXERCISES AND PRACTICAL POSSIBILITIES 1.- Manual star-delta circuit of Asynchronous three-phase motor with wound rotor. 2.- Manual reversing operations of Asynchronous three-phase motor with wound rotor. 3.- Timer Sequential Control operations of Asynchronous threephase motor with wound rotor. 4.- Automatic star/delta starter of Asynchronous three-phase motor with wound rotor. 5.- Automatic star-delta reversing circuit of Asynchronous threephase motor with wound rotor. 6.- Countercurrent braking. 7.- Automatic soft starter of Asynchronous three-phase motor with wound rotor. REQUIRED SERVICES - Electrical supply: three-phase, 380V/50 Hz or 208V/60 Hz, 20 Kw. DIMENSIONS AND WEIGHTS AEL-ACWRA: -Dimensions: 640 x 320 x 920 mm approx. (25.19 x 12.59 x 36.26 inches approx.) -Weight: 70 Kg approx. (154 pounds approx.) 6

Optional AEL-ACWRA/ICAI. Interactive Computer Aided Instruction Software System: With no physical connection between unit and computer (PC), this complete software package consists of an Instructor Software (EDIBON Classroom Manager -ECM-SOF) totally integrated with the Student Software (EDIBON Student Labsoft -ESL- SOF). Both are interconnected so that the teacher knows at any moment what is the theoretical and practical knowledge of the students. Instructor Software - ECM-SOF. EDIBON Classroom Manager (Instructor Software). ECM-SOF is the application that allows the Instructor to register students, manage and assign tasks for workgroups, create own content to carry out Practical Exercises, choose one of the evaluation methods to check the Student knowledge and monitor the progression related to the planned tasks for individual students, workgroups, units, etc... so the teacher can know in real time the level of understanding of any student in the classroom. Innovative features: User Data Base Management. Administration and assignment of Workgroup, Task and Training sessions. Creation and Integration of Practical Exercises and Multimedia Resources. Custom Design of Evaluation Methods. Creation and assignment of Formulas & Equations. ECM-SOF. EDIBON Classroom Manager (Instructor Software) Application Main Screen Equation System Solver Engine. Updatable Contents. Report generation, User Progression Monitoring and Statistics. ECAL. EDIBON Calculations Program Package - Formula Editor Screen ETTE. EDIBON Training Test & Exam Program Package - Main Screen with Numeric Result Question ERS. EDIBON Results & Statistics Program Package - Student Scores Histogram 7

Innovative features: Student Log-In & Self-Registration. Existing Tasks checking & Monitoring. Optional Student Software - ESL-SOF. EDIBON Student Labsoft (Student Software). ESL-SOF is the application addressed to the Students that helps them to understand theoretical concepts by means of practical exercises and to prove their knowledge and progression by performing tests and calculations in addition to Multimedia Resources. Default planned tasks and an Open workgroup are provided by EDIBON to allow the students start working from the first session. Reports and statistics are available to know their progression at any time, as well as explanations for every exercise to reinforce the theoretically acquired technical knowledge. Default contents & scheduled tasks available to be used from the first session. Practical Exercises accomplishment by following the Manual provided by EDIBON. Evaluation Methods to prove your knowledge and progression. Test self-correction. ESL-SOF. EDIBON Student LabSoft (Student Software) Application Main Screen Calculations computing and plotting. Equation System Solver Engine. User Monitoring Learning & Printable Reports. Multimedia-Supported auxiliary resources. For more information see ICAI catalogue. Click on the following link: /en/files/expansion/icai/catalog EPE. EDIBON Practical Exercise Program Package Main Screen ECAL. EDIBON Calculations Program Package Main Screen ERS. EDIBON Results & Statistics Program Package - Question Explanation * Specifications subject to change without previous notice, due to the convenience of improvement of the product. REPRESENTATIVE: C/ Del Agua, 14. Polígono Industrial San José de Valderas. 28918 LEGANÉS. (Madrid). ESPAÑA - SPAIN. Tel: 34-91-6199363 Fax: 34-91-6198647 E-mail: edibon@edibon.com Web: Edition: ED01/17 Date: September/2017 8