ELECTRIC ACTUATORS WITH FAIL SAFE UNIT For automatic opening or closing of a valve in the event of an emergency

Similar documents
ELECTRIC ACTUATORS WITH FAIL SAFE UNIT For automatic opening or closing of a valve in the event of an emergency

ELECTRIC MULTI-TURN ACTUATORS for the automation of industrial and special valves with torque requirements up to 120,000 Nm

Factor 1) Modulating torque 4) [Nm] 200 F14 G1/2 GK : :

Factor 2) 160:1 6) /(30) FA10 (FA14) :1 6) /(30) FA10 (FA14) 27 86

GEARBOXES for operation of industrial valves

Factor 1) Modulating torque 4) [Nm]

Reduction ratio. Factor 1)

Valve attachment Gearbox Reduction ratio :1 5) : ,

ELECTRIC MULTI-TURN ACTUATORS for valve automation in the oil & gas industry with high torque requirements

Factor 3) Max. input torques Flange 38 GS : F ,000 F10 F ,000 F12 82:

1 potential-free change-over contact (max. 24 V DC/1 A) for SIL collective failure signal SIL functions - safety functions Standard: Safe ESD

VALVITALIA VALVE OPERATORS

Technical Data Part-turn gearbox 2SP78

LEDEEN SEF. Smart electric fail-safe actuator and control systems

Offshore and Onshore Applications Lucifer TM 2/2 and 3/2 ways 316L Stainless Steel solenoid valves

QUARTER-TURN ELECTRIC ACTUATORS

Multi-turn actuators. Product description

Features. Suitable for use in SIL 2 applications. Available in LP low power version with less than 1.65 A current consumption. General application

System Electropneumatic Converters (Proportional Valves) Electronic Process Controllers Signal Converters

AIR TORQUE HEAVY DUTY. AT-HD Series. Scotch Yoke Actuators "fully made in Italy" The results of the long experience in design

Modular Flameproof Brakes

Series 3730 Electropneumatic Positioner Type

E Range of Electro - Hydraulic Linear and Rotary Actuators. Technical Specification.

Hafner-Pneumatik. Excellence in Pneumatics

Position Switches Series 8060/2

ELECTRIC ACTUATORS. for industrial applications and civil vessels ELEKTRISCHE STELLANTRIEBE

Electrical position indicators and combi switchboxes for linear and quarter turn valves

Valve Accessories. Limit switches, solenoid valves, lock-up valves, supply pressure regulators, volume boosters, quick exhaust valves, applications

Keystone PremiAir Pneumatic Actuators

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

Position Switches Series 8070/2

Motors and Gearboxes for Warehouse Logistics. Energy efficient Compact Sustainable

Part-turn gearboxes GS 50.3 GS 250.3

Diaphragm Actuators Favorable Variety Pneumatic Diaphragm Actuators Electric Actuators Hydraulic Actuators

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Measuring insert for resistance thermometer Model TR10-A

ABB ACTUATORS & POSITIONERS

Linear Valve Electric Actuator

A comprehensive range of pneumatic actuators, providing compact, reliable and economical powered operation for all types of quarter-turn valves.

Automation Capabilities

POSITIONERS and Controls for Complete Valve Automation

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module

Automation is the techniques and equipment used to achieve automatic operation or control.

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Poppet Valves Series. Keeping the World Flowing

Position Switches Series 8074/2

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

Tyco PremiAir Pneumatic Actuators

The reliable choice for the Oil and Gas industries

A good connection. International approvals.

Direct-acting 2/2-way plunger valve

Redundant Control System

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals

RC 200. Technical Data. High reliability pneumatic actuators. REMOTE CONTROL has been manufacturing pneumatic actuators in Sweden since 1961.

Positioners Converters Limit Switches Position Transmitters Solenoid Valves Accessories. Selection and Application

Operating Instructions

Modular Explosion Proof Brakes. IECLine rev 0

Motors and Gearboxes for Warehouse Logistics. Energy efficient Compact Sustainable

Sepehr Hydraulic Asia

Measuring insert For thermocouple with flameproof enclosure (TC10-L) Model TC10-K

Magnetic Level Gauges

Q u a r t e r T u r n E l e c t r i c A c t u a t o r s

Variable Frequency Drive NEW! Moving your Control. Forward VFD from Unitronics kW Single Phase kW Three Phase

EX Series. Electric Actuators for Ball and Butterfly Valves

VALVCON ADC-SERIES ELECTRIC ACTUATOR WITH OPTIONAL BATTERY BACK-UP POWER

Direct mounting NAMUR solenoid valves for process valve actuators New Revolutionary Design- Worldwide Patents Pending

FICHA TÉCNICA DE PRODUTO

PRODUCTS AND CAPABILITIES ACTUATION & CONTROLS ACTUATION & CONTROLS PRODUCTS AND CAPABILITIES

Q Range Watertight Single-Phase Electric Quarter-turn Actuators for part-turn valves and dampers

LINEAR ACTUATORS. Type SL 95 / SL 80 / KL 95 up to 12,000 N with high protection class (IP)

Customized ELECTRO-HYDRAULIC CONTROL SYSTEM

AH / AV. Advanced Series Unit Heaters AH / AV. Ruffneck

IndustrIal ValVes Product overview

Lexium integrated drives

Q max (see specifications table)

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Customized drive solutions

2/2-way Angle-Seat Valve for medium up to +180 C, threaded port connection, DN 15-65

GP & GH Range. Pneumatic and Hydraulic Actuators for Quarter-Turn Valves. Established Leaders in Actuation Technology

LEDEEN HS Series. Compact actuators

Level Measurement Point level measurement - RF Capacitance switches

NAF-Duball ball valves

Butterfly valves Plastic and Metal

V200 Positioner. V200 P Pneumatic Positioner. V200 E Electropneumatic Positioner. Housing Material: Cast aluminium with polyester coating

OPTIGAS 4010C Technical Datasheet

BETA SWITCHES FOR HAZARDOUS AREA

CONTROLS. S98 Pneumatic Actuator

Valves For Process Industry. Engineered Pneumatic Solutions.

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

YFC. Limit switch. Ex d. 24 operating head types

Pekos valve automation

Unused flameproof threads for cable glands have to be closed with certified plugs.

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Low voltage asynchronous motors Motors for use in potentially explosive atmospheres

Explosion proof electric motor For Fuel dispensing application. Main characteristic

Jet Fuel Conductivity Analysers & Additive Management systems

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Transcription:

ELECTRIC ACTUATORS WITH FAIL SAFE UNIT For automatic opening or closing of a valve in the event of an emergency

In recent years, safety requirements in process plants have become increasingly demanding. Even in case of emergency, the system must be safe for persons and the environment. Actuators play a crucial role here, since it is their task to open or close a valve in case of emergency and to ensure that the plant remains in safe condition. With their new FQM fail safe unit, AUMA offer innovative and safe actuator solutions for automatic operation of valves in case of emergencies making use of stored mechanical energy. The FQM fail safe unit meets the requirements of safetyrelated applications up to SIL 2/SIL 3 and is basically maintenance-free. An explosion-proof version is also available. MECHANICAL SOLUTION FOR UTMOST SAFETY When relying on safe opening or closing of a valve, mechanical actuator solutions provide top safety. In case of need, the new FQM fail safe unit generates the required torque by means of a constant force spring purely on a mechanical basis. No electrical power is required for fail safe operation. CONSTANT TORQUE The constant force spring motor with patent pending provides a constant torque during fail safe operation and this across the complete travel. During standard operation, the constant force spring is disengaged and is not operated. As a consequence, actuator sizing can be relatively small. VARIABLE RUNNING SPEEDS Running speeds for fail safe operations are adjustable. Furthermore, the actuator can operate the valve into the defi ned end position at reduced speed. This avoids pressure peaks within the pipeline and protects the valve. ELECTRIC PART-TURN ACTUATORS WITH FQM FAIL SAFE UNIT 2

EASY INTEGRATION Actuators with FQM fail safe unit are integrated into systems in the same way as standard AUMA actuators. The fail safe unit seamlessly adapts to the modular AUMA product design. It is combined with AUMA SQ part-turn actuators or AUMA SA multi-turn actuators paired with GS part-turn gearboxes. Integration into the DCS is made as for the standard devices by means of AC integral controls. Operating concept, interfaces and communication remain homogeneous across all valves installed within the plant. EASY RETROFITTING Thanks to their identical interfaces, the fail safe unit can be retrofi tted within existing plants. For example, if the safety requirements for an application have intensifi ed. And even better, the already installed actuator may often be retained. VERSATILE IMPLEMENTATION AUMA actuators with FQM fail safe unit are particularly suited to automate butterfl y valves as well as ball and plug valves at a swing angle of up to 90. They are the perfect choice if part-turn actuators require safe opening or closing in case of emergencies. Industrial applications Fail safe actuators are used in all markets and applications. In water reservoirs, they prevent drainage in case of burst pipes, for example. Steam generating boilers in power plants and fi re protection measures in road and railway tunnels are further typical examples. Applications in the oil & gas industry The oil & gas industry imposes highest quality standards not least due to the superior danger of potential explosions. The explosionproof fail safe unit caters for the required safety level. Overfi ll protections in tank farms, drainage protection in tanks and pipelines or use in gas regulating and metering stations are merely a few of the versatile implementations in the oil & gas industry. 3 2015.06.08

FUNCTION FQM fail safe unit AUMA part-turn actuators with fail safe unit ensure that the valve is operated to a safe position in the event of power failure or in case an emergency signal is issued. Selection can be made whether the valve is to be operated into position OPEN or CLOSED. Normal operation All AUMA actuator functions are available as usual in normal operation. The torque is transmitted directly from the actuator through the fail safe unit to the valve. Fail safe operation The fail safe operation is completely independent of the power supply and is exclusively supplied on a mechanical basis by means of the energy stored in the coiled up constant force spring. SQ A fail safe operation is initiated in case of power failure or if an emergency signal is issued. This is independent of AC actuator controls. The constant force spring is activated during fail safe operation and transmits the generated torque to the valve by means of a planetary gearing. During the complete fail safe operation, the spring provides an almost constant torque. FQM 1 1 Constant force spring motor The core of the fail safe unit is a mechanical constant force spring motor providing the required torque to open or close the valve in case of an emergency. When connecting the actuator to the mains and after acknowledgement by the DCS, the fail safe unit is initialised and the constant force spring is fully wound by means of an integrated electric motor. For this, the spring is wrapped in inverted direction on a drum. During fail safe operation, the integrated electric motor additionally acts as a brake, allowing setting of various running speeds during fail safe operation. 4

SA AC GS 2 Solenoid with toggle lever By means of a toggle lever, the solenoid retains the spring in the fully wound position. In case of power failure or if an emergency signal is issued, the solenoid releases the spring and initiates the fail safe operation. 2 3 Planetary gearing The planetary gearing acts as overriding gear arrangement. In normal operation, it transmits the drive shaft movement directly to the part-turn movement of the valve. During standard operation, the constant force spring is disengaged and is not operated by the actuator. 3 During the fail safe operation, the planetary gearing transmits the energy stored in the spring to the valve. Here, the actuator is inactive. 4 4 End stops with integral end position switches The internal end stops limit the swing angle of the valve. The end position switches are automatically set during the setting procedure of end positions OPEN and CLOSED and do not require separate adjustment. 5 Valve attachment The interface to the valve is made in compliance with EN ISO 5211. The torque is transmitted from the output drive shaft to the valve by means of a splined coupling which is available in different versions: unbored, with square bore, two-fl at or as bore with keyway. 5

Electric part-turn actuator FQM fail safe unit can be combined with both AUMA SQ part-turn actuators as well as with AUMA SA multi-turn actuators paired with GS part-turn gearboxes. The electric actuator can thus be individually and perfectly adjusted to the application requirements: > SQ part-turn actuators for open-close duty, SQR for modulating duty as well as SQEx and SQREx for potentially explosive atmospheres > SA multi-turn actuators paired with GS part-turn gearboxes for open-close operation, SAR for modulating operation, as well as SAEx and SAREx for potentially explosive atmospheres AC integral actuators controls AC integral actuator controls assume communication control between DCS and actuator. Controls are available with various interfaces to the DCS allowing both parallel signal transmission and fi eldbus communication. Supported are, for example, Profi bus DP, Modbus RTU, DeviceNet, Foundation Fieldbus as well as HART and Wireless HART. Advanced diagnostic functions enable preventive maintenance and integration of actuators into asset management systems. Integral local controls also allow for local actuator operation. Advantages of the AUMA constant force spring motor The main drawbacks of conventional solutions using simple return springs are that the spring transmits the highest torque at the start of the travel. Towards the end of the travel, the applied torque is reduced when it is needed most to ensure safe valve seating. Hence, the springs have to be oversized to ensure that the required torque is still supplied towards the end of the travel. With the constant force spring with patent pending by AUMA, the spring supplies an almost constant torque across full travel. Consequently, constant force spring motor sizing is lower than for conventional return springs. Torque in % T 180 140 110 100 Further advantage: Thanks to the overriding gear arrangement, the spring must not be operated during normal operation and remains completely wound. This allows selection of smaller actuators. Furthermore, premature spring fatigue can be prevented and the valve is protected against excessive torques. OPEN (0 ) CLOSED (90 ) Time Return spring Required valve torque AUMA constant force spring

SERVICE CONDITIONS AUMA actuators with FQM fail safe unit are designed to highest reliability and long product life and fulfil their automation tasks in most severe and harsh environments. IP68 ENCLOSURE PROTECTION Like the actuators, the FQM fail safe unit is available with increased enclosure protection IP68 in compliance with IEC 60529. The permissible immersion height of 8 m head of water is specifi ed for a max. duration of 96 hours. AMBIENT CONDITIONS FQM fail safe unit in standard version is designed for temperatures between 30 C and +70 C, the low temperature version for temperatures between 40 C and +60 C. Further temperature ranges are available on request. CORROSION PROTECTION The AUMA corrosion protection system with the two-layer powder coating is certifi ed by the TÜV and provides top-quality mechanical and chemical resistance. Actuators equipped with FQM fail safe units are suitable for environmental conditions C5-I and C5-M in compliance with EN ISO 12944-2. They comply with the requirements for use in areas with high salinity, almost permanent condensation, and high pollution. EXPLOSION PROTECTION Both actuators and FQM fail safe units were tested and certifi ed in close collaboration with national and international certifi cation bodies. Approvals have been obtained from authorities worldwide for use in potentially explosive atmospheres, including ATEX (Europe), IECEx (international), FM (USA) and ROSTECHNADSOR/ EAC (TR-CU) (Russia). > Explosion protection according to ATEX ATEX II2G Ex d,e IIC T4 or T3 > Explosion protection according to FM: Class I, Div. 1, Groups B,C,D Class II, Div. 1, Groups E,F,G Class III FIREPROOF VERSION AUMA actuators with FQM fail safe units are available in fi reproof version to ensure safe closing and opening of valves even in the event of a fi re. Devices fi tted with K-MASS TM fi re protection coating preserve functionality during 30 minutes at temperatures as high as 1,100 C. Consequently, they fulfi l the requirements in compliance with UL 1709. SIL Fail safe requirements and functional safety are often closely linked. In particular, components with increased reliability and lower probability of failure are required if system requirements include safeguarding the safety for persons and environment in case of emergencies. AUMA fail safe unit complies with the highest demands regarding functional safety according to IEC 61508 and is suitable for safety-related systems up to SIL 2/SIL 3. TECHNICAL DATA Type FQM 05.1 FQM 07.1 FQM 10.1 FQM 12.1 Mains voltage Control voltage for EMERGENCY input Output mounting flange Max. output torque Swing angle Operating time suitable part-turn actuator EN ISO 5211 [Nm] [s] SQ SA with GS F05 150 SQ 05.2 F07 F07 SA 07.2 + GS 50.3 300 5 30 SQ 07.2 F10 SA 10.2 + GS 50.3 to 90 F10 600 SQ 10.2 SA 07.2/SA 10.2 + GS 50.3 F12 F12 SA 07.2/SA 10.2 + GS 63.3 1200 10 60 SQ 12.2 F14 SA 10.2 + GS 80.3 50 Hz: 220 V, 230 V, 240 V, 380 V, 400 V, 415 V 60 Hz: 440 V, 460 V, 480 V, 500 V 24 V DC/1 A 115 V AC 7

AUMA Riester GmbH & Co. KG Aumastr. 1 D-79379 Muellheim Tel +49 7631-809-0 Fax +49 7631-809-1250 riester@auma.com AUMA subsidiaries or representatives are implanted in more than 70 countries. For detailed contact information, please refer to our website. www.auma.com Subject to changes without notice. The product features and technical data provided do not express or imply any warranty. Y006.906/003/en/1.15 Certificate Registration No. 12 100/104 4269