EXPERIMENTAL INVESTIGATIONS OF DOUBLE PIPE HEAT EXCHANGER WITH TRIANGULAR BAFFLES

Similar documents
NOVATEUR PUBLICATIONS INTERNATIONAL JOURNAL OF INNOVATIONS IN ENGINEERING RESEARCH AND TECHNOLOGY [IJIERT] VOLUME 1, ISSUE 1 NOV-2014

CFD Investigation of Influence of Tube Bundle Cross-Section over Pressure Drop and Heat Transfer Rate

Enhance the Performance of Heat Exchanger with Twisted Tape Insert: A Review

GEOMETRICAL PARAMETERS BASED OPTIMIZATION OF HEAT TRANSFER RATE IN DOUBLE PIPE HEAT EXCHANGER USING TAGUCHI METHOD D.

CFD analysis of triple concentric tube heat exchanger

Design, Fabrication and Testing of helical tube in tube coil heat exachanger

CFD ANALYSIS ON LOUVERED FIN

Heat Transfer Enhancement for Double Pipe Heat Exchanger Using Twisted Wire Brush Inserts

CFD Analysis of Double Pipe Heat Exchanger with Twisted Tape Insert in Inner Pipe

ABSTRACT I. INTRODUCTION III. GEOMETRIC MODELING II. LITERATURE REVIW

CFD analysis of heat transfer enhancement in helical coil heat exchanger by varying helix angle

An Experimental Investigation for the Rate of Heat Transfer in Double Pipe Heat Exchanger with Fins on Inside Surface of Internal Tube

A Review on Experimental Investigation of U-Tube Heat Exchanger using Plain Tube and Corrugated Tube

Heat Transfer in Rectangular Duct with Inserts of Triangular Duct Plate Fin Array

International Journal of Scientific & Engineering Research, Volume 6, Issue 10, October ISSN

Design and experimental analysis of pipe in pipe heat exchanger

Experimental investigation of shell-and-tube heat exchanger with different type of baffles

International Journal of Advance Engineering and Research Development

Experimental Investigation of Heat Transfer characteristics Enhancement through Grooved Tube

Comparison of Heat transfer Enhancement in Tube in Tube heat exchanger using Different Turbulent Generator.

Experimental Study of Heat Transfer Augmentation in Concentric Tube Heat Exchanger with Different Twist Ratio of Perforated Twisted Tape Inserts

THERMAL ANALYSIS OF HELICALLY GROOVED COIL IN A CONCENTRIC TUBE HEAT EXCHANGER

CONSTRUCTION AND ANALYSIS OF TUBE IN TUBE TYPE HEAT EXCHANGER

Simulation Studies on the Effect of Porous Twisted Plate Inserts on the Performance of Fire Tube Steam Packaged Boiler

HEAT TRANSFER ENHANCEMENT BY V-NOZZLE TURBULATORS

Abstract In this study the heat transfer characteristics inside a rectangular duct with circular, rectangular, drop

CONJUGATE HEAT TRANSFER ANALYSIS OF HELICAL COIL HEAT EXCHANGE USING CFD

Design and Performance Analysis of Louvered Fin Automotive Radiator using CAE Tools

Enhanced Heat Transfer Surface Development for Exterior Tube Surfaces

COMPUTATIONAL ANALYSIS TO MAXIMIZE THE HEAT TRANSFER RATE OF DOUBLE TUBE HELICAL COIL HEAT EXCHANGER

Review on Comparative Study between Straight Tube Heat Exchanger and Helical Coil Heat Exchanger

SINGLE-PHASE CONVECTIVE HEAT TRANSFER AND PRESSURE DROP COEFFICIENTS IN CONCENTRIC ANNULI

ENHANCEMENT OF HEAT TRANSFER RATE AND REDUCTION OF SHELL SIDE PRESSURE DROP IN HELIX HEAT EXCHANGER WITH CONTINUOUS HELICAL BAFFLES

Design and Fabrication of Shell and Tube Type Heat Exchanger and Performance Analysis

Performance Evaluation Of A Helical Baffle Heat Exchanger

Experimental Investigation on Turbulent Flow Heat Transfer in a Horizontal Circular Pipe using Coil and Twisted Tape Inserts

Efficiency Improvement in Shell and Tube Heat Exchanger Using CFD Tool

Analysis to Determine Heat Transfer Using Twisted Tape Inserts In a Horizontal Tube

EXPERIMENTAL ANALYSIS AND PERFORMANCE CHARACTERISTIC OF HEAT TRANSFER IN SHELL AND TWISTED TUBE HEAT EXCHANGER

Heat Exchangers (Chapter 5)

Modeling and Fluid Flow Analysis of Wavy Fin Based Automotive Radiator

International Journal of World Research, Vol: I Issue XXXVII, January 2017 Print ISSN: X

EFFECT OF EXTERNAL THREADED INSIDE TUBE ON HEAT TRANSFER RATE IN A CONCENTRIC TUBE HEAT EXCHANGER: A CRITICAL REVIEW

ADVANCES in NATURAL and APPLIED SCIENCES

CRITICAL ASSESSMENT OF LITERATURE IN THE FIELD OF ENHANCED HEAT TRANSFER TECHNIQUES

An Approach for Enhancement of Heat Transfer Using Conical Convergent Ring Inserts In Tube

Experimental Study on Heat Enhancement of Helixchanger with Grooved Tubes

A REVIEW ON INVESTIGATION OF HELICAL COIL HEAT EXCHANGER

ENHANCEMENT OF HEAT TRANSFER COEFFICIENT THROUGH HELICAL COIL

Forced Convection Heat Transfer Analysis through Dimpled Surfaces with Different Arrangements

TEMPERATURE APPROACH OPTIMIZATION IN THE DOUBLE PIPE HEAT EXCHANGER WITH GROOVE

Design of Shell and Tube Type Heat Exchanger using CFD Tools

Effect of Nanofluid on Friction Factor of Pipe and Pipe Fittings: Part I - Effect of Aluminum Oxide Nanofluid

Optimisation of Double Pipe Helical Tube Heat Exchanger and its Comparison with Straight Double Tube Heat Exchanger

Cross Flow Heat Exchanger H352

Experimental Analysis and Performance Characteristic Of Heat Transfer In Shell and Twisted Tube Heat Exchanger.

Visualization of Flow and Heat Transfer in Tube with Twisted Tape Consisting of Alternate Axis

FLOW AND HEAT TRANSFER ENHANCEMENT AROUND STAGGERED TUBES USING RECTANGULAR VORTEX GENERATORS

An Experimental Study of Thermo-Hydraulic Performance of Modified Double Pipe Heat Exchanger Using Mesh Inserts

Design and Performance Study of Shell and Tube Heat Exchanger with Single Segmental Baffle Having Perpendicular & Parallel-Cut Orientation.

Thermal Analysis of Shell and Tube Heat Exchanger Using Different Fin Cross Section

Influence of Pressure Drop, Reynolds Number and Temperature in the Design of Double Pipe Heat Exchanger on Hot Fluid Side in Inner Pipe

Numerical Analysis of Compact Heat Exchanger for Flow Distribution

ENHANCEMENT OF HEAT TRANSFER IN SHELL AND TUBE HEAT EXCHANGER WITH TABULATOR AND NANOFLUID

Thermal Analysis of Multi Tube Pass Shell and Tube Heat Exchanger

HEAT TRANSFER ENHANCEMENT BY USING TWISTED TAPE INSERTS WITH CIRCULAR HOLES IN FORCED CONVECTION

CFD Analysis for Designing Fluid Passages of High Pressure Reciprocating Pump

Exhaust Gas Waste Heat Recovery and Utilization System in IC Engine

Prediction of Thermal Deflection at Spindle Nose-tool Holder Interface in HSM

Department of Mechanical Engineering, D Y Patil College of Engineering, Akurdi, Pune , Savitribai Phule Pune University, India

CFD Integrated Optimum Design and Prototyping of Shell and Tube Heat Exchanger

SOLAR FLAT PLATE COLLECTOR HEAT TRANSFER ANALYSIS IN THE RAISER WITH HELICAL FINS Mohammed Mohsin Shkhair* 1, Dr.

Numerical and Experimental Investigations of Heat Transfer in Double Pipe Heat Exchangers with Inner and Annular Twisted Tape

Comparative Study of Different Configurations of Fuel Oil Heat Exchanger

Investigation for Flow of Cooling Air through the Ventilated Disc Brake Rotor using CFD

Experimental and CFD Analysis of Exhaust Manifold to Improve Performance of IC Engine

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET)

Research Article Thermohydraulic Analysis of Shell-and-Tube Heat Exchanger with Segmental Baffles

Investigation of Comparison of Three Different Tube Bundles of Heat Exchanger

Heat transfer enhancement of a single row of tube

DESIGN OF THROTTLE BODY: A COMPARATIVE STUDY OF DIFFERENT SHAFT PROFILES USING CFD ANALYSIS

Effect of Contaminated Oil on Temperature Variation of Tilting Pad Thrust Bearing of Bronze Pads having Catenoidal Profile

REVIEW PAPER ON INVESTIGATION OF PERFOMANCE FOR SHELL AND TUBE HEAT EXCHANGER

Manufacturing and Comparative Analysis of Threaded Tube Heat Exchanger with Straight Tube Heat Exchanger

INVESTIGATION OF HEAT TRANSFER CHARACTERISTICS OF CIRCULAR AND DIAMOND PILLARED VANE DISC BRAKE ROTOR USING CFD

Thermal Unit Operation (ChEg3113)

Quality Improvement in Design Process of Shell & Tube Type Heat Exchanger by Computer Integrated 3D Modeling

CFD Analysis and Comparison of Fluid Flow Through A Single Hole And Multi Hole Orifice Plate

Cross Flow Heat Exchanger H352

Experimental investigation and performance analysis of triple concentric helical tube heat exchanger

THERMAL ANALYSIS OF SHELL AND TUBE HEAT EXCHANGER

Analysis of Air Flow and Heat Transfer in Ventilated Disc Brake Rotor with Diamond Pillars

Performance of Solar Flat plate by using Semi- Circular Cross Sectional Tube

Experimental Investigation on Mixing time Analysis of Jet Mixer

A Survey On Heat Transfer Of Air Cooled Internal Combustion Engine Various Fin Cutting Shape

FLUID FLOW. Introduction

CFD Analysis of Heat Transfer Prediction for Corrugated Shell & Tube Heat Exchanger

Computational Investigation of Normal and Hybrid Cooling Fins of Internal Combustion Engine

PERFORMANCE ANALYSIS ON DOUBLE PIPE HEAT EXCHANGER USING WIRE COILED AND PIN WIRE COILED TURBULATOR INSERTS

International Research Journal of Engineering and Technology (IRJET) e-issn:

Transcription:

International Research Journal of Engineering and Technology (IRJET) e-issn: 2395-56 Volume: 3 Issue: 8 Aug-216 www.irjet.net p-issn: 2395-72 EXPERIMENTAL INVESTIGATIONS OF DOUBLE PIPE HEAT EXCHANGER WITH TRIANGULAR BAFFLES Madhav Mishra 1, U. K Nayak 2 1 M. Tech student, Department of Mechanical engineering, BIT, Sindri, Dhanbad, India, madhavmisra89@gmail.com 2 Assistant Professor, Department of Mechanical engineering, BIT, Sindri, Dhanbad, India, ujjwalnayak77@gmail.com ------------------------------------------------***--------------------------------------------- Abstract - A set of the experiments were carried out for this dissertation to investigate and compare the heat transfer behaviour in a double pipe concentric tube heat exchanger with and without triangular for both parallel and counter flow arrangements. The test section is a horizontal annular passage formed by two concentric tubes with an inner to outer diameter ratio of 3.17 and length of 2438 mm. Heat is only transferred from the inner tube in which hot fluid is flowing to the annulus which is well insulated. Triangular baffle with dimensions of 4 mm base, 8mm height and 1.5 mm thickness are used in the present study. In the beginning we conducted the experiment without any baffle to get the performance parameter for plane heat exchanger and then with baffle of pitches 5 mm and 1 mm. The effects of the spacing and mass flow rate of fluid is examined on the thermal performance of heat exchanger. It is found that the effectiveness increases with increase in flow rate of cold fluid and average effectiveness also increases when pitch of are 1 mm and 5 mm by 1.42 and 1.62 times in parallel flow and 1.34 and 1.62 in counter flow that of smooth tube respectively. The other performance parameter like heat transfer coefficient and heat transfer rate obtained through experiment is also increases. The effectiveness method is used for calculation of overall heat transfer coefficient and effectiveness. Key Words: Double pipe, Heat capacity, LMTD ( ), Triangular heat exchanger, Overall Heat Transfer Coefficient, ( ) etc. 1. INTRODUCTION Heat exchangers are the equipment that is commonly used to transfer heat between two flowing fluids at different temperatures without any mixing of fluid with each other. Transfer of the energy from one fluid to another fluid can be done either by conduction, convection or radiation or with all modes of heat transfer. Heat exchangers are very important components in engineering systems, ranging from the heavy industries, such as power or metallurgy, chemical, automotive, through the high technique ones such as electronics, to production of every day consumers goods like refrigeration, air conditioning systems, etc. [1] Here an experimental investigation has been performed to study the effects of the on a concentric tube heat exchanger. Baffles are attached to the heated surface so that it provide an additional heat transfer surface area and to promote useful turbulence. Due to the presence of the flow is separated, reattached and creates reverse flow. Recently, many experiments have been carried out. Most investigation tells about the optimal baffle geometry that increases heat transfer performance for a flow rate. An investigation had been carried out to compare the heat transfer performance of hexagonal pin-fin heat sinks with various commonly used fin geometries. It is found that for the given flow rate and pressure gradient, the Nusselt number of hexagonal fin geometry yield a higher in comparison to square fins, and a lower in comparison to circular fins. The heat transfer performance in staggered hexagonal fin geometry is similar in-line circular performance at most Reynolds numbers in the range considered here[2].experimental investigation is performed to know the effects of the baffle alignment (staggered and in-line), open area ratio, Reynolds number, baffle height and on the heat transfer increment, friction factor and the different thermal performance parameter for turbulent flow of air in a rectangular duct with perforated [3]. Reported experimental and numerical analysis of hydrodynamic and heat transfer characteristics of a heat exchanger with single- helical. CFI model is used and compared the performance of heat exchanger with single - segmental [4]. Experimental and analytical study has been carried out on water-to-water heat transfer in tube-tube heat exchanger. These tube tube heat exchangers are successfully demonstrated for condenser and evaporator in heat pumps, milk chilling and pasteurizing application [5]. In this paper the study of shell and tube heat exchanger is carried out also the factors which affect the performance of heat exchanger 216, IRJET Impact Factor value: 4.45 ISO 91:28 Certified Journal Page 1137

International Research Journal of Engineering and Technology (IRJET) e-issn: 2395-56 Volume: 3 Issue: 8 Aug-216 www.irjet.net p-issn: 2395-72 and its details discussion is given. The investigation is carried out in small shell and tube heat exchanger with counter flow arrangement. The parameters used for thermal analysis are baffle inclination, baffle spacing, flow rates of cold and hot fluids, diameter of tube etc. by using CFD [6]. After the study of large number of literature it is found that various experiments have been carried out for improvement in heat transfer rate in heat exchanger by using different methods. But, I hardly found any experiment that has been carried out with triangular in double tube heat exchanger to enhance heat transfer rate from hot fluid to cold fluid. 2. EXPERIMENTAL APPARATUS AND PROCEDURE The schematic diagram of experimental set-up of double concentric tube heat exchanger is shown in above figure 1 and the photograph of experimental set up is in figure 2 respectively. The devices used in this set ups are orifice meter to measure flow rate with the help of Vertical U- tube Manometer, however the flow rate of hot fluid is also calculated by measuring the time to fill a known volume of bucket. Digital thermal indicator (DTI) and Thermocouple are fitted to measure temperature at inlet and outlet of fluids. The end of thermocouple wires connected with standard male plug in order to connect them with the digital thermometer. Geyser and Pump is used to heat and circulates the hot fluid in inner Copper tube at a temperature range of 4 to 55. The ID and OD of inner copper tube is 14 mm and 16 mm respectively. G.I pipe of ID 5.8 mm is used as outer tube and cold water is flowing in the annulus between these two tube had a constant inlet temperature of 28. Length of heat exchanger is 2438 mm. Triangular copper of 4 mm base, 8 mm height and 1.5 mm thickness are used at a pitch of 1 mm and 5 mm at the outer surface of inner tube. Six-six numbers of are used at a single peripheral space. Working fluid water is stored in in two tanks in which hot and cold water is stored. Figure 3, 4 and 5 illustrate the inner tube of heat exchanger i.e. Cupipe without triangular and, Triangular baffled with 1 mm and 5 mm pitches. Figure 1: The Schematic diagram of experimental set-up Figure 2: Experimental setup of triangular baffled heat exchanger Figure 3: Cu-pipe without triangular Figure 4: Triangular with 1 mm pitch on cupipe 216, IRJET Impact Factor value: 4.45 ISO 91:28 Certified Journal Page 1138

International Research Journal of Engineering and Technology (IRJET) e-issn: 2395-56 Volume: 3 Issue: 8 Aug-216 www.irjet.net p-issn: 2395-72 = =...(8) Now the effectiveness is known, the heat transfer rate can be very easily calculated by using the equation Figure 5: Triangular with 5 mm pitch on cupipe 2.1 Mathematical Analysis Assuming that there is no heat loss to the surroundings and potential and kinetic energy Changes are negligible from the energy balance in a heat exchanger. We have Heat given up by the hot fluid Q = (t h1 t h2). (1) Heat picked up by the cold fluid Q = (t c2 t c1) (2) Total heat transfer rate in the heat exchanger Q = U.A... (3) Where, =... (4) Heat Exchanger The heat exchanger effectiveness ( ) is defined as the ratio of actual heat transfer to the maximum possible heat transfer, Thus, Q= C min (t h1 - tc 1) (9) Thus, Overall heat transfer coefficient U=.. (1) 3. RESULTS AND DISCUSSION To compare the different performance parameter of heat exchanger without and with of pitches 1 mm and 5 mm some graphs are plotted. Figure 6 and figure 7 shows the variations of effectiveness with different mass flow rate of cold fluid for parallel and counter flow respectively. The plot clearly shows that the effectiveness decreases with increasing mass flow rate. of both triangular baffled heat exchangers is greater than the plane tube heat exchanger. However from two graphs it is also clearly seen that the effectiveness of heat exchanger with 5 mm triangular baffled pitch is more than 1 mm baffled pitch. So it can be concluded that using of in heat exchanger effectiveness increases however if decreases effectiveness also increases..5.4 Flow Plane HE =... (5) The actual heat transfer rate Q can be determined by writing an energy balance over either side of the heat exchanger Q = (t h1 t h2 ) = (t c2 t c1). (6).3.2.1.118.16.19.219.244.266 1 mm 5 mm Maximum heat transfer rate for both parallel flow or courtier flow heat exchanger Q max = C min (t h1-t c1) (7) Figure 6: Variation of effectiveness with mass flow rate of parallel flow Thus,, 216, IRJET Impact Factor value: 4.45 ISO 91:28 Certified Journal Page 1139

Overall Heat Transfer coeff.(w/m2k) Overall Heat Transfer coeff.(w/m2k) International Research Journal of Engineering and Technology (IRJET) e-issn: 2395-56 Volume: 3 Issue: 8 Aug-216 www.irjet.net p-issn: 2395-72.6 Flow Flow.5.4.3.2.1.118.16.19.219.244.266 Plane HE 1 mm 5 mm 5 4 3 2 1.118.16.19.219.244.266 plane HE 1 mm 5 mm Figure 7: Variation of effectiveness with mass flow rate of counter flow Mass Flow Rate(kg/sec) The variations of overall heat transfer coefficient with mass flow rate which is calculated by experimentally observed data for parallel and counter flow heat exchanger is shown in figure 8 and figure 9 respectively. The plot clearly shows that the heat transfer coefficient increases by using triangular in both set-ups as compare to heat exchanger without. However from two graphs it is also clearly seen that the heat transfer coefficient of triangular baffle heat exchanger with 5 mm pitch is more than 1 mm baffled pitch. So it can be concluded that using of in heat exchanger heat transfer coefficient increases however it also increases when pitch of decreases. Figure 9: Variation of Overall heat transfer coefficient with mass flow rate of counter flow The value of effectiveness for parallel and counter flow arrangements are compare in plot for increasing mass flow rates are shown in the figure 1, 11 and 12 for all three experimental set up of heat exchanger without, with es of 1 and 5 mm respectively. From the plot it is clearly seen that the value of effectiveness for counter flow is more than parallel flow for the all three set of heat exchanger. From the graph it is seen that there is an optimum mass flow rate at which gap of effectiveness for parallel counter flow is minimum 45 4 35 3 25 2 15 1 5 Flow plane HE 1 mm 5 mm.35.3.25.2.15.1.5.118.16.19.219.244.266 Flow of plane HE Flow of plane HE Mass Flow Rate(kg/sec) Figure 8: Variation of Overall heat transfer coefficient with mass flow rate of parallel flow Figure 1: variation of effectiveness with mass flow rate of parallel and counter flow of plane heat exchanger i.e. without 216, IRJET Impact Factor value: 4.45 ISO 91:28 Certified Journal Page 114

International Research Journal of Engineering and Technology (IRJET) e-issn: 2395-56 Volume: 3 Issue: 8 Aug-216 www.irjet.net p-issn: 2395-72.5.45.4.35.3.25.2.15.1.5 Figure 11: variation of effectiveness with mass flow rate of parallel and counter flow of plane heat exchanger with 1 mm Figure 12: variation of effectiveness with mass flow rate of parallel and counter flow of plane heat exchanger with 5 mm 4. CONCLUSION Experimental investigations of effectiveness and overall heat transfer coefficient of double pipe heat exchanger without triangular and with spacing of 1 mm and 5 mm carried out for both parallel and counter flow. The following conclusion could be made:.6.5.4.3.2.1.118.16.19.219.244.266.118.16.19.219.244.266 pitch 1mm pitch 1 mm pitch 5mm pitch 5 mm The effectiveness, heat transfer coefficient and heat transfer rate increases with the decrease in baffle spacing and baffled tube heat exchanger have batter thermal performances than smooth tube for both the cases. Triangular of 1 and 5 mm pitches enhance the average effectiveness by 1.42 and 1.62 times in parallel flow and 1.338 and1.62 in counter flow that of smooth tube respectively Triangular of 1 and 5 mm pitches enhance the average heat transfer rate by 1.6 and 1.9 times in parallel flow and 1.48 and 1.67 in counter flow that of smooth tube respectively. We found that the insulation has a significant effect on heat exchanger performance. From the calculation it can be seen that in many observations the heat loss by hot fluid is more than the heat gain by cold fluid this is because of insulations provided is not sufficient to stop heat loss. From the results it can be concluded that the performance of triangular baffled heat exchanger is much better than that of smooth tube HE, therefore improvement in the energy saving lead to validate its use in different applications. Also similar results had been found by Sarmad A. Abdal Hussein when he carried out the investigation of double pipe heat exchanger by using semi-circular disc. REFERENCES [1] Sarmad A. Abdal Hussein (215), Experimental Investigation of Double Pipe Heat Exchanger by using Semi Circular Disc Baffles, International Journal of Computer Applications, Volume 115 No. 4,pp 13-17. [2] Eaman Hassan Muhammad (213), A Comparison of the Heat Transfer Performance of a Hexagonal Pin Fin with Other Types of Pin Fin Heat Sinks, International Journal of Science and Research (IJSR),pp 1781-1788 [3] Abd-Elghanyand Afify, R. I.(1997), "Turbulence and heat transfer measurements in circular pipe", Engineering over doughnut-and-disc Research Journal, Vol. 52, pp1-2 [4] Yong-Gang Lei et al., (28) Design and Optimization of heat exchanger with helical, chemical Engineering science, 63, pp.4386-4395. [5]Rane and Tandale (23), Tube tube heat exchangers Filed PCT/IN3/377 [6] Gajanan P Nagre, A. V. Gadekar (213), Design and Thermal Performance Analysis of Shell and Tube Heat Exchanger by Using CFD-A Review International Journal of Science and Research (IJSR), ISSN (Online): 2319-764,pp 953-955 216, IRJET Impact Factor value: 4.45 ISO 91:28 Certified Journal Page 1141