Installation Guide. Heater Interface Cable for Mass Sensitive Detector Accessory G1590A

Similar documents
Installation Guide. Purged Packed Inlet, Electronic Pneumatics Control on 6890 GC Accessory G1551A

Installation Guide NPD/ECD Chemical Filters Accessory 19199N

Installation Guide. Nitrogen-Phosphorus Detector on 6890 GC Accessories G1575A, G1576A, G1594A, G1599A

Installation Guide. Flame Ionization Detector on a 6890 GC. Accessories G1561A, G1562A, G1591A, G1598A

Installation Guide Thermal Conductivity Detector Accessory 19232E

Installation Guide. Auxiliary Pressure Control Manifold on 6890 GC Accessory G1570A

Installation Guide. Flame Ionization Detector on a 6850 GC Accessory G2621

Installation Guide. Thermal Conductivity Detector on a 6850 GC Accessory G2623A

Installation Guide. Volatiles Interface for 6890 Gas Chromatograph Accessory G2319A

Nickel Catalyst Tube Accessory 19205A

Installing a Purged Packed (PP) Inlet

Installing a Cool On-Column Inlet

Agilent G1554A On-Column Capillary Inlet with EPC

Installing a PTV Inlet

Installing a PTV Inlet

Installing the CO 2 Cryogenic Oven Cooling Kit

Installing an Auxiliary Pressure Control Module

Installing an Auxiliary Pressure Control Module

Installing a Purged Packed Inlet

Nickel Catalyst Tube on a 6820 GC, Accessory G4318A

Agilent G3510A/G3511A Multimode Inlet

Installation Guide. Agilent 7683 Automatic Liquid Sampler

Installing the Flame Ionization Detector EPC Flow Control Manifold

Agilent G3969A Transfer Line Interface for an Agilent 7697A HS Accessory

Valve Box and Valve Accessories G4315A, G4316A, G4317A

Upgrading the Boxer LAD blower module

Agilent G2738A Upstream Capillary Interface

MK7 GTI Electronic Folding Mirror Conversion

Installation Instructions

Catalyser Introduction. 3. Hazard Information. 2. Area of Application. 3.1 Symbology

Switching DC Power Supply

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation

nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual

Installation Instructions

INSTALLATION INSTRUCTIONS

Model Fixed Rack-Mount Kit

260 Solvent Vapor Exit Accessory

Prodigy HDLV Generation II Pump Panel

Altivar 61/71 Adjustable Speed Drives Plastic Kits and Power Terminal Kit

Installation Instructions for Foam Marker ZMAX

Katalysator Nr /

LVPS Replacement Instruction Sheet

Installing the Boxer fan upgrade kit

Upgrading the Sure Coat Modular Gun Control System

Installing the 6850 Direct Valve Column Connector Kit

INSTALLATION INSTRUCTIONS TABLE OF CONTENTS

User s Manual Power Supply. IM E 3rd Edition. Yokogawa Electric Corporation

Installation Note for Solvent Selection Valve Upgrade Kit (G1360A)

Fiber Optic Illuminator. Model 21AC Model 21DC

L DURAMAX LBZ EGR DELETE GDP TUNING

System 3 ZB1PS Device Chassis. Operator s Manual

PET UNIT DOSE TABLE INSTALLATION MANUAL FN: Rev A 1/18

HP Adjustable Depth Fixed Rail Kit Installation

Installing the G2743A/G2745A Valve Actuator Kits

Galaxy VM. Battery Breaker Box Installation 09/

6890 Power Related Information

Siemens Drives & PLCs

Alcatel-Lucent 7310 DC Metro Cell AWS (B4) Kit MC-DBR1, MC-DBR2, MC-DBR3, MC-DBR4, MC-DBR5. Installation Manual

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

DURAMAX LBZ EGR DELETE

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Installation Instructions Electric Heaters 5 20 kw

PET UNIT DOSE CABINET

CRECOMZR054B00 CRECOMZR055B00. VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS WARNING TABLE OF CONTENTS

Model 1693, 1694 Switching DC Power Supply

In addition to this instruction sheet, the following are included in this kit (some additional parts are included for future maintenance):

Installation Instructions Electric Heaters 5 20 kw

2017 Current Ford Raptor Bump Stop Kit Installation Instructions

Installation Instructions

Control Panel Interface Upgrade Installation Guide For Model 200i and 250i Motorcycle Dynamometers Serial Number 202xxxx.

P/N: OD-AI60. Designed for use on the Ford 6.0L Powerstroke diesel pickup truck

Battery Replacement. Installation Instructions. Summary of Changes. Catalog Number 2711P-RY2032. Original Instructions

5 Removal and replacement

Installing the Switch Chassis

AIS and 40 kva 400 V. Site Preparation and Installation Manual

Installation Instructions

- Wiring Brochure Mixing Expansion Module 440

Triple Output Power Supply

NR Rack Installation Guide

FOG LAMPS INSTALL KIT

User s Manual Power Supply IM E. 5th Edition

HP 6890Series Gas Chromatograph. Installation Guide. Flame Ionization Detector. Accessories HP G1561A HP G1562A HP G1591A HP G1598A

Part Number: TTU-BGB14-DRL TTU-BGP14-DRL

Electrically Held to Mechanically Latched Contactor

Operating Manual. Agilent 7673 Automatic Liquid Sampler

Installation Instructions for Foam Marker INTERMEDIATE also applies: JR, JR36

Product Manual (Revision D) Original Instructions. PM Speed Adjusting Motor for UG-8 Governors. Operation Manual

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

Installation Instructions 500 A Current Sensor Kit for D2h/D4h/D7h/D8h Enclosure Sizes VLT Series FC 102, FC 103, FC 202, and FC 302

Forbidden Diesel Performance Ford 6.7L Powerstroke EGR Delete Instructions 6.7L EGR DELETE BY FORBIDDEN DIESEL PERFORMANCE. Page 1

CONSOLE MANAGEMENT CONTROLLER

BATTERY REPLACEMENT GUIDE

Installation Instructions. PowerFlex 700 Drive - Frame 8 Components Replacement

Replacing a Gun RTD. Instruction Sheet P/N B. 1. Introduction. Using this Instruction Sheet

Installation Instructions

A-dec LED Dental Light Head on a Demonstration Stand INSTALLATION GUIDE

Lamp House with 2.5 kw lamp

A. Preparing the charge harness. Start by removing the plastic covers by the battery terminal.

Altivar 61/71 Adjustable Speed Drives Spare Parts Kits

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Transcription:

Installation Guide Heater Interface Cable for Mass Sensitive Detector Accessory G1590A

Agilent Technologies, Inc. 2001 All Rights Reserved. Reproduction, adaptation, or translation without permission is prohibited, except as allowed under the copyright laws. Part number G1590-90107 First Edition, OCT 2001 Replaces part number G1590-90100, Installation Guide - Heater Interface Cable for the HP Mass Selective Detector. Printed in USA Safety Information The Agilent Technologies 6890 Gas Chromatograph meets the following IEC (International Electrotechnical Commission) classifications: Safety Class 1, Transient Overvoltage Category II, and Pollution Degree 2. This unit has been designed and tested in accordance with recognized safety standards and designed for use indoors. If the instrument is used in a manner not specified by the manufacturer, the protection provided by the instrument may be impaired. Whenever the safety protection of the Agilent 6890 has been compromised, disconnect the unit from all power sources and secure the unit against unintended operation. Refer servicing to qualified service personnel. Substituting parts or performing any unauthorized modification to the instrument may result in a safety hazard. Disconnect the AC power cord before removing covers. The customer should not attempt to replace the battery or fuses in this instrument. The battery contained in this instrument is recyclable. Safety Symbols Warnings in the manual or on the instrument must be observed during all phases of operation, service, and repair of this instrument. Failure to comply with these precautions violates safety standards of design and the intended use of the instrument. Agilent Technologies assumes no liability for the customer s failure to comply with these requirements. WARNING A warning calls attention to a condition or possible situation that could cause injury to the user. CAUTION A caution calls attention to a condition or possible situation that could damage or destroy the product or the user s work. + Indicates a hot surface * Indicates earth (ground) terminal Sound Emission Certification for Federal Republic of Germany Sound pressure Lp < 68 db(a) During normal operation At the operator position According to ISO 7779 (Type Test) Schallemission Schalldruckpegel LP < 68 db(a) Am Arbeitsplatz Normaler Betrieb Nach DIN 45635 T. 19 (Typprüfung) Agilent Technologies, Inc. 2850 Centerville Road Wilmington, DE 19808-1610 USA

Overview This document describes the procedure for installing a heater interface cable for the Agilent 5973 Mass Selective Detector (MSD) on the Agilent 6890 Gas Chromatograph (GC). Before following this procedure, refer to the safety information on the inside front cover. Parts list Actuator solenoid bracket Two screws for attaching the actuator solenoid bracket to the GC Auxiliary zone/valve box harness Heated zone extension cable APG remote cable, 9M/9M MSD ship kit Tools T-20 Torx driver Electrostatic protection such as a grounded wrist strap (part no. 9300-0969 for small wrists, 9300-0970 for large wrists) Steps If you do not have a valve box, complete all five steps. If your GC has a valve box, you can skip step 3. 1. Preparing the GC 2. Preparing the bracket 3. Installing the bracket assembly on the main board 4. Routing the heated zone extension cable 5. Restoring the GC to operating condition 1

Preparing the GC WARNING Hazardous voltages are present in the mainframe when the GC power cord is plugged in. Avoid a potentially dangerous shock hazard by unplugging the power cord before removing the side panels. 1. Turn off the GC and unplug the power cord. Allow time for all heated zones to cool, then turn off supply gases at their sources. Power switch 2. Remove the left side cover. Loosen the two captive screws on the top edge with a T-20 Torx driver. Slide the cover to the rear, then lift it up and off. Left side cover 2

Caution Board components can be damaged by static electricity. Use a properly grounded static control wrist strap when removing the electronics covers. 3. Raise the Detector cover (gray plastic top cover with the holes and ventilation slots) to the vertical position. Examine the hinge in the right rear corner. If the hinge is a metal bracket attached to the oven top, pull the clip at its top toward you to release the hinge pin. Push the pin to the left to release the cover. Raise the right side of the cover and remove it. If there is no metal hinge bracket, raise the right side of the cover and remove it. 4. Remove the right side cover. Loosen the two captive screws on the top edge with a T-20 Torx driver. Slide the cover to the rear and lift it off. Captive screws Right side cover 3

5. Remove the electronics top cover. Press the rear locking tab toward the front of the GC while lifting the back of the cover. Slide the cover back, up, and out of the GC. Electronics top cover Rear locking tab (underneath cover) 6. Remove the fan cover. a. Loosen the screw on the right side of the fan cover. b. Slide the cover to the right to disengage it from the left mounting post. c. Lift the cover up and off. Fan cover 4

Preparing the bracket 1. If not installed, attach two screws to the solenoid bracket as shown. 2. Attach the heated zone extension cable to the A2 connector on the actuator solenoid bracket. Heated zone extension cable Attach 2 screws Bracket A2 V4 V3 V2 V1 A1 Harness 5

Installing the bracket assembly on the main board If your GC has a valve box installed, you can skip this section. Caution Board components can be damaged by static electricity. Use a properly grounded static control wrist strap when removing the electronics covers. 1. Connect the solenoid bracket assembly to the GC by installing and tightening the two screws with a T-20 Torx driver. Be careful not to crimp or break any of the wires connected to the mainboard. 2. Locate the 2 8 connector on the main board. Plug the harness into the connector. Note: The main board may differ from this figure, but the 2 x 8 connector and the bracket mounting screws are in the same locations. 2 x 8 connector Tighten two screws Plug into 2 x 8 connector 6

Routing the heated zone extension cable 1. Route the heated zone extension cable through the slot shown. 2. Route the cable through the three plastic grommets. Grommets 1 and 2 are on the oven top; grommet 3 is on the left side of the GC. a. Squeeze the lipped end of grommet 1 and pull it away from the bracket. b. Locate the slit in the grommet. c. Place the heated zone extension cable in the grommet. d. Push the grommet into the bracket. e. Repeat these steps for grommets 2 and 3. Grommet 1 Grommet 2 Route the cable through this slot Grommet 3 7

Restoring the GC to operating condition 1. Reinstall the fan cover. 2. Reinstall the left side cover. 3. Reinstall the detector cover. 4. Reinstall the right side cover. 5. Reinstall the electronics top cover. 6. Plug in the power cord and turn on the GC. 8

Printed on recycled paper. This product is recyclable. Agilent Technologies, Inc. Printed in USA OCT 2001 G1590-90107