FHS2-UNV-56S SPECIFICATIONS

Similar documents
FHS2-UNV-36L INSTALLATION INSTRUCTIONS

FHSCP-UNV-10P-L-SD SPECIFICATIONS

This Driver Will Operate Constant Current LED Arrays With a Working Voltage Between 11-56VDC And Not Exceeding 20W.

FHSCP-UNV-10P-L-SD INSTALLATION INSTRUCTIONS

MODEL : FHS2-UNV-36L

SPECIFICATION SHEET : FHS2-UNV-36L

Cat# DC LED Array Emergency Driver

FHEZ10A24 FHEZ10A24 - CEC 24" EZ EXIT EM T-Grid

VKMUNV018RDxxxA. UNV DC Engines Retrofit Kits with 0-10V Dimming Universal Voltage (120~277) DC Engine

TRMUNV065EC8XXA TRAUNV065EC8XXA Universal Voltage LED Canopy Retrofit Kit

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING:

120VAC / Universal Input Half Round LED DC Engines and LED DC Engine Retrofit Kits

SURE-LITES FBP140XLP Instruction Manual

Emergency and Exit Solutions

120VAC / Universal Input Round LED DC Engines and LED DC Engine Retrofit Kits

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

Emergency and Exit Solutions Product Selection Guide. LED Emergency Backup Fluorescent Emergency Ballasts Emergency Lights & Exit Signs

OPTOTRONIC Programmable LED Emergency Driver and Battery Pack

Installation And Operation Instructions For FHSCP-UNV Series Emergency LED Drivers Models: FHSCP-UNV-5WL, 7.8WL, 10.7WL, 13.

IMPORTANT SAFEGUARDS

Installation and Operation Instructions 10/04/13

120VAC / Universal Input Half Round LED DC Engines and LED DC Engine Retrofit Kits

LED Emergency Drivers

120VAC / Universal Input Round LED DC Engines and LED DC Engine Retrofit Kits

EEQ SERIES COMPACT FLUORESCENT EMERGENCY FACTORY SEALED LIGHTING FIXTURES

120VAC / Universal Input Rectangular LED DC Engines and LED DC Engine Retrofit Kits

Installation Instructions & Users Manual IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST

Self-Testing Industrial Series

120VAC / Universal Input Round LED DC Engines and LED DC Engine Retrofit Kits

UFO-RP3 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

UFO-RP2 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Prestige Series Edge-Lit LED Sign IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination

LED Driver Selection Guide

LED Driver Selection Guide

BAL3000 BAL3000. Fluorescent Emergency Ballast Lumens. Specification Sheet. Emergency Ballast 1/19/2012. Project: Catalog#: Approved by:

Spectron Industrial Series

UL AND CODE COMPLIANCE

SPECIFICATION SHEET :FH6-DUAL-3000L. Project Type Model # Remarks

3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

EMIU 720W Mini Inverter

LED Retrofit Kits Vol. 1

Emergency lighting units EM LED Light Engines

MA-4025 Solar Charger Patent pending

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES

15W (+/- 1W) 5.08" diameter x 0.75 H. Energy Star Luminaire CSD

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

KT-EMRG-1400-SL /B. 3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination

TJT120034ACxxxB TJT120034ACxxxC 120V LED DirectAC Engine and Retrofit Kits

TrustSight LED Emergency Lighting

TJT120015ACxxxB TJT120015ACxxxC 120V LED DirectAC Engine and Retrofit Kits

EXP-EMG-2L-LE6. Explosion Proof Bug Eye Emergency LED Fixture Instruction Manual

Europe Featured Products Catalogue

Installation Instructions & Users Manual

Intelligent DC UPS Module

TMU040005ELXXXA TMU040005ELXXXB

MIRRORLITE RECESSED EMERGENCY LIGHTING

TMU040010ELXXXA TMU040010ELXXXB TMU040010ELXXXC

Sure-Lites. Installation Instructions for the Sure-Lites UX Self Powered Exit Sign with Self Diagnostics. IB505037EN Important Safeguards

VR22-MU-xxx-8yy-xxxxA

Lighting Accessories - EMPACK2T Kit

c-go 24V/6A 24V/8A 24V/12A

62.6g / 0.13lbs. RoHS Compliant Dry and Damp Location IC Over Temperature Control

PSL600 MVOLT SD INSTALLATION INSTRUCTIONS ! IMPORTANT SAFEGUARDS!

DATA SHEET: LED PANEL

Emergency lighting units EM powerled

34W (+/- 1W) 9.55" diameter x 0.81 H. 2.5kV Common and Differential mode (Per ES Ring Wave Test) Sound Rating / Noise

LED Emergency Drivers

GUARD-LITE SERIES EMERGENCY UNIT EQUIPMENT

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

Informer Compact Series

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

Uninterruptible Power Supply

23W (+/- 1W) Leading Edge (TRIAC) or Trailing Edge (ELV) /100% ~ 10% Beam Angle CRI Operating Temperature Range (Ta) Maximum Engine Case Temperature

Twelve Unit Rapid Charger

Lithium Power Supply

W here the re is MiBoxer t her e is power. C4 Smart Charger. Users Manual

Installation Instructions Central Battery Units

OPTOTRONIC LED Power Supply OTi 30W Emergency Driver Technical Specifications

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

HIGHBAY RAIL 400W INSTALLATION INSTRUCTIONS

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

The WDS A Dimmer Users Manual Rev , 2012 City Theatrical, Inc.

Installation Instructions

OPTOTRONIC LED Power Supply OTi 50W Emergency Driver - Technical Specifications

350 ma CONSTANT CURRENT LED DC MODULE, 17 LINEAR, 1845 LUMENS

Where There is Miboxer There is Power. User Manual. Model No.: C2-6000

Installation Manual. Integrated Prepaid Keypad Meters. For HXE34-KP Meters(CT & CTPT Connection) Hexing Electrical Co., Ltd. [2013.

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS!

User manual. Solar Hybrid 1-5KVA. Uninterruptible Power Supply / Charger

Emergency lighting units EM powerled

FLUORESCENT EMERGENCY BALLAST Lumens. When using this lighting device safety precautions should be followed at all times

User Manual 5KVA/5KW INVERTER / CHARGER. Version: 1.3

Transcription:

SPECIFICATIONS MECHANICAL DATA NiCd/LiFePO4 E313578 Emergency LED Driver Universal Voltage: 100-277VAC, 50/60Hz Output Wattage range of 1.2-20W Output Current range of 100mA - 700mA Output voltage range of 12-56VDC This Driver Will Operate The Following LED Modules: Any LED module designed to accept an input voltage range of 12-56VDC and can operate up to a current of 700mA. General Specifications Input Voltage Input Current Input Power Red Lead White/Black Lead Standby Input Power Driver Type Output Current Output Voltage Range Output Power Number of Output Channels RFI/EMI Output Type Battery Type Battery Capacity Available Battery Recharge Time Battery Discharge Time Ambient Operating Temperature Range Input Surge Protection Protections Service Life Approvals / Class 100-277VAC, 50/60Hz 0.1A Max. 6W Max. 3A,60V Max. 2A Max. <0.8W Constant Current 100mA -700mA Initial (Refer to accesory chart) 12-56VDC 20W Max. 1 Channel FCC Part 15 Class B, EN55015 LED Class 2 NiCd 9.6VDC or LiFePO4 9.6VDC 900mAh, 1000mAh, 1200mAh, 1500mAh, 1800mAh, 3000mAh, 4000mAh, 6000mAh 24-32 Hours (Refer To Battery chart) 90 Minutes Min. NiCd 0 C to 50 C (32 F to 122 F), LiFePO4 10 C to 50 C (50 F to 122 F) FHSBATCC3-3 -20 C to 50 C (-4 F to 122 F) 2.5KV Ring Wave Battery Over Discharge Protection Output Short Circuit Protection 50,000 hours RoHS, curus 1310, curus 924, CEC Title 20, CE, Dry and Damp Locations Mechanical Data 20.87"(530± 12.7mm) 14.96"(380± 12.7mm) 12.99"(330± 12.7mm) 0.09"(R2.25mm) 2.99"(76± 5mm) 1.18"(30mm) 0.75"(19mm) 8.5"(216± 0.5mm) 5.51"(140± 5mm) 8.9"(226± 0.5mm) 9.5"(241.3± 0.5mm) 1"(25.4mm) Case Tolerance=±0.02" Page1of13 2017-730-1 Rev A

Important Safety Instructions When using electrical equipment and this lighting device basic safety precaution should be followed at all times including but not limited to the following: PLEASE READ CAREFULLY AND FOLLOW ALL INSTRUCTIONS FOR YOUR OWN SAFETY IMPORTANT: Do not connect battery until fixture is installed. IMPORTANT: An un-switched AC power source of 100VAC to 277VAC is required. This device is designed for use in fixtures listed for dry and damp locations. CAUTION: Make sure all electrical connections conform to the National Electrical Code and all applicable local regulations. CAUTION: Do not let power supply cords touch hot surfaces. CAUTION: Do not mount near gas or electric heaters. CAUTION: Battery is rechargeable Ni-Cd or LiFePO4 type and must be recycled or disposed of properly. Do not use this emergency driver with accessory equipment other than recommended by manufacturer; failure to follow this may cause an unsafe condition. Servicing should only be performed by qualified service personnel. Do not use this emergency driver for other than intended use. Not suitable for high-risk task area lighting. Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel. IMPORTANT: The output EM power will not exceed the max power rating of the battery. IMPORTANT: Indicator (LED light) illuminated indicates battery in charge mode when AC power is applied. It is recommended and required by applicable code to test emergency ballast to ensure proper function of the system; push the test switch for thirty (30) seconds every thirty (30) days to ensure the emergency driver is functioning by illuminating the light source. Conduct a ninety (90) minutes discharge test one (1) time per year; LED light source should be illuminated for a minimum of ninety (90) minutes. ASSEMBLY and FIELD INSTALLATION WIRING: WARNING: AC power must be off before proceeding with assembly or installation of emergency driver. TESTING SYSTEM: The emergency battery requires a charge minimum of one (1) hour before testing the circuit. A full charge requires twenty four (24) or thirty two (32) hours, depending upon battery pack. Please refer to battery chart for charging time. Fulham Head Quarters: Fulham Co., Inc 12705 South Van Ness Ave. Manufacturer: North China Fulham Electronic Co. Ltd. No. 9 Xingchang Road, Nanshao Zhen Changping Science Park, Beijing, P.R. China SAVE THESE INSTRUCTIONS Page2of13 2017-730-2 Rev A

Wiring Diagrams 1 INPUT SIDE OUTPUT SIDE RED TO LED (+) INPUT 100mA - 700mA harness (Need separately purchase) BLK BLK/WHT TO LED DRIVER (100W MAX.) INPUT POWER NOTE: Drill ½ Dia. hole in mounting. Plate to insert test switch. Double insulation between the input wire and battery wire. WHT LED ARRAY Ø SWITCH TEST BATTERY Wiring Diagram (TYP) LINE HOT( 100V - 277V) WHITE(COMMON) BLACK WHT/BLK WHITE WALL SWITCH BLACK LED DRIVER RED (+) BLUE (-) FHS2-UNV-56S DRIVER MUST BE GROUNDED TEST SWITCH RED (+) LED ARRAY BLK RED BATTERY WIRING DIAGRAM (EMERGENCY ONLY) LINE HOT( 100V - 277V) WHITE(COMMON) BLACK WHT/BLK FHS2-UNV-56S TEST SWITCH RED (+) BLK LED ARRAY RED BATTERY Page3of13 2017-730-3 Rev A

Battery Chart Fulham Model No. Chemistry Compliant Pack Capacity Max Load for 90 min. Battery Voltage Recharge Time FHSBATT8-AA.9 NiCd 900mAh 4W 9.6V 24Hrs FHSBATT8-C3 NiCd 3000mAh 16W 9.6V 24Hrs FHSABATT8-D4 NiCd 4000mAh 20W 9.6V 24Hrs FHSBATT8-C3L* NiCd 3000mAh 16W 9.6V 24Hrs FHSBATL3-1 LiFePO4 RoHS 1000mAh 4W 9.6V 24Hrs FHSBATL3-1.5 LiFePO4 RoHS 1500mAh 8W 9.6V 24Hrs FHSBATL3-3 LiFePO4 RoHS 3000mAh 16W 9.6V 24Hrs FHSBATL6-1.5 LiFePO4 RoHS 3000mAh 14W 9.6V 24Hrs FHSBATL6-3 LiFePO4 RoHS 6000mAh 20W/16W** 9.6V 32Hrs FHSBATL6-.6 LiFePO4 RoHS 1200mAh 4W 9.6V 24Hrs FHSBATL9-.6 LiFePO4 RoHS 1800mAh 8W 9.6V 24Hrs FHSBATL6-1.5L* LiFePO4 RoHS 3000mAh 14W 9.6V 24Hrs FHSBATL6-3L* LiFePO4 RoHS 6000mAh 20W/16W** 9.6V 32Hrs FHSBATCC3-3 LiFePO4 RoHS 3000mAh 14W/10W** 9.6V 24Hrs FHSBATL6-1.5S LiFePO4 RoHS 3000mAh 14W 9.6V 24Hrs FHSBATL3-1.5S LiFePO4 RoHS 1500mAh 8W 9.6V 24Hrs CAUTION: Replace battery only with corresponding part number. *Note: These batteries do not include mounting means, separate mounting brackets are available. **Note: This battery rating applies for Canada use only. Harness Extension Battery Model Number Harness Part Number Description FHSBATT8-AA.9 FHS-EXT12L HotSpot 12" Battery Extension FHSBATT8-C3 FHS-EXT12M HotSpot 12" Battery Extension FHSBATT8-D4 FHS-EXT12H HotSpot 12" Battery Extension FHSBATL3-1 FHS-EXT12M HotSpot 12" Battery Extension FHSBATL3-1.5 FHS-EXT12M HotSpot 12" Battery Extension FHSBATL3-3 FHS-EXT12M HotSpot 12" Battery Extension FHSBATL6-1.5 FHS-EXT12M HotSpot 12" Battery Extension FHSBATL6-3 FHS-EXT12M HotSpot 12" Battery Extension FHSBATL6-.6 FHS-EXT12M HotSpot 12" Battery Extension FHSBATL9-.6 FHS-EXT12M HotSpot 12" Battery Extension FHSBATCC3-3 FHS-EXT12M HotSpot 12" Battery Extension FHSBATL6-1.5S FHS-EXT12M HotSpot 12" Battery Extension FHSBATL3-1.5S FHS-EXT12M HotSpot 12" Battery Extension Accessory Harness (Wire length 24") Part Number Description Part Number Description FHS-HARNESS-100 100 ma LED Harness FHS-HARNESS-125 125 ma LED Harness FHS-HARNESS-150 150 ma LED Harness FHS-HARNESS-175 175 ma LED Harness FHS-HARNESS-200 200 ma LED Harness FHS-HARNESS-225 225 ma LED Harness FHS-HARNESS-250 250 ma LED Harness FHS-HARNESS-300 300 ma LED Harness FHS-HARNESS-350 350 ma LED Harness FHS-HARNESS-400 400 ma LED Harness FHS-HARNESS-450 450 ma LED Harness FHS-HARNESS-500 500 ma LED Harness FHS-HARNESS-550 550 ma LED Harness FHS-HARNESS-600 600 ma LED Harness FHS-HARNESS-650 650 ma LED Harness FHS-HARNESS-700 700 ma LED Harness Page4of13 2017-730-4 Rev A

FHSBATT8-AA.9 4W, 900mAh, 9.6V FHSBATT8-C3 16W, 3000mAh, 9.6V Page5of13 2017-730-5 Rev A

FHSBATL3-1 4W, 1000mAh, 9.6V FHSBATL3-1.5 8W, 1500mAh, 9.6V FHSBATL3-3 16W, 3000mAh, 9.6V FHSBATL6-1.5 16W, 3000mAh, 9.6V Page6of13 2017-730-6 Rev A

FHSBATT8-D4 20W, 4000mAh, 9.6V FHSBATL6-3 20W/16W, 6000mAh, 9.6V Page7of13 2017-730-7 Rev A

FHSBATL6-.6 6W, 1200mAh, 9.6V FHSBATL9-.6 10W, 1800mAh, 9.6V Page8of13 2017-730-8 Rev A

FHSBATL6-1.5L 16W, 3000mAh, 9.6V Mounting Bracket Dimensions (Optional) FHSBATSC6-1.5L Page9of13 2017-730-9 Rev A

FHSBATL6-3L 20W/16W 6000mAh, 9.6V Do not apply pressure, contains critical components at this location. Mounting Bracket Dimensions (Optional) FHSBATSC6-3L Page 10 of 13 2017-730-10 Rev A

FHSBATT8-C3L 16W, 3000mAh, 9.6V Mounting Bracket Dimensions (Optional) FHSBATSC8-C3L Page 11 of 13 2017-730-11 Rev A

FHSBATCC3-3 14W/10W, 3000mAh, 9.6V FHSBATL6-1.5S 16W, 3000mAh, 9.6V FHSBATL3-1.5S 8W, 1500mAh, 9.6V Page 12 of 13 2017-730-12 Rev A

TEST SWITCH INDICATOR STATUS: Indicators Type LED Indicators Status EM Driver Status/Mode Solid Green System OK/AC OK (Self-diagnostic Enabled or Disabled). Single Color Indicator Solid RED ON Single Color Indicator Single Color Indicator Single Color Indicator None. Both LEDs OFF None. LED OFF Slow Flashing Red, 4s on/1s off Slow Flashing Red, 4s on/1s off Flashing Red, 1s on/1s off Flashing Red, 1s on/1s off Flashing Green, 2s on/2s off Single Color Indicator Flashing Red, 2s on/2s off Single Color Indicator Single Color Indicator Single Color Indicator Fast Flashing Red, 0.1s on/0.1s off Fast Flashing Red, 0.1s on/0.1s off Very Slow Flashing Red, 1s on/7s off Over temperature. Very Slow Flashing Red, 1s on/7s off Very Slow Flashing Red, 4s on/4s off Very Slow Flashing Red, 4s on/4s off Normal working in EM mode. Battery not detected, check battery switch or connection. Replace battery. Self-Diagnostic test underway. Abnormal driver performance, replace driver. LED output load is Short/Over Current/Over Voltage/Open Circuit in EM Mode. TEST SWITCH OPERATIONS: 1. EM Test: Press and hold test button (>1s)to enter EM mode for testing in normal AC powered. 2. Manual Self-Diagnostic: After charging twelve (12) hours or battery fully charged, quickly press the test button three times within two seconds to force the controller to enter a Self-Diagnostic cycle. To quit the self-diagnostic cycle after engaged press and hold the test button for ten seconds. 3. Enable/Disable Auto Self-Diagnostic: Press and hold the test button for one second, then release and quickly press the test button two times, then release and press and hold the test button for two seconds. When properly executed the indicator on the test button will display the appropriate color for the Enable/Disable status. A flashing of 2.5s ON/0.5s OFF means "Enabled", while a flashing of 0.5s ON/2.5s off means "Disabled". Once Enable/Disable is set the status color on the test button will remain the same throughout normal operation (refer to Indicator Status Table). 4. Enable/Disable Self-Diagnostic Status: Fast click 2 times within 2s to query the Self-Diagnostic Enabled/Disabled status. The indicator would blink for current status for 3 cycles. 2.5s ON/0.5s OFF stands for Enabled. 0.5s ON/2.5s OFF stands for Disabled. 5. Exit Output Short Circuit/No Load/Over Voltage Protection: When the test button flashes red for 4s on/4s off, press and hold the test switch for 10 seconds. Programming: Unless otherwise programmed the output will self-program to the rated output of the harness. This driver can be programmed using Fulham SmartSet TPSB-100 or TPSM-100E. Programming features include the following: Enable/Disable Self-Diagnostic Output EM Current : 0mA,100-700mA * When programmed to 0mA; output current defaults to rating of output harness(refer to accessory harness chart). Page 13 of 13 2017-730-13 Rev A