LASERMET MINIATURE LED SIGN POWER AND SWITCH UNIT. Installation Instructions

Similar documents
IS46/PS33 Current Power Supply System

ATLV MaxSG. Low Voltage Metal Enclosed Switchgear

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

ADDENDUM to INSTALLATION INSTRUCTIONS for Grant Solar Pump Station

Installation & User Instructions

Actionpac LNS4. Panel Installation Datasheet. Actionpac LNS4 RELEASE 1.0 JUNE In partnership

HE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual

xboard safety, reliability effectively combining and performance safety, reliability and performance in commercial and industrial applications

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

Underfloor to desk 231

EdgeLED TM Range. Installation and Operating Instructions EdgeLED TM RANGE INSTALLATION NON-EMERGENCY LUMINAIRES PRE INSTALLATION

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Miniature Circuit Breaker

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

QUALITY ASSURANCE & DOCUMENTATION

Sivoia QED R Installation Instructions Please Leave for Occupant

25W LED Cross Bezel Bulkhead Light

Pack Cat. Nos. Single pole push switches gang 2 way push switch gang 2 way push switch marked PRESS gang 2 way

Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE.

The Powermatic User Guide Test Sieve Shaker

U Series Installation Guide

ZonePlus Z322 zone valve Installation and commissioning instructions

Consumer unit solutions to meet the requirements of the new 17th edition amendment 3 regulations

Doc Ref: WD027/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Operating Instructions

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

24 Hour Immersion Heater Time Controller

Installation instructions for ATS panel Ref:ATS --/2 M2GC705 Issue

DEEP SEA ELECTRONICS PLC

Greater protection UNDERSTANDING THE 17TH EDITION CONSUMER UNITS / PRODUCT GUIDE

Guidelines How To Wire DRH Modules

GROUP TP&N DISTRIBUTION BOARD TYPE B. Distribution boards for modern commercial & industrial installations

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

INFRESCO-S-4kW X20034 Issue: 7

SDM320D / SDM320A. Single phase din rail meter SDM320D / SDM320A user manual

CLP POWER HONG KONG LIMITED. SUPPLY RULES March 2001

Uninterruptible power supply Supply MEg101.4

HLS Watt Halogen Illuminator Service Manual

Installation and setting instructions. Gatelock Type VL10. Publication Number: II063/0601 Part Number:

Effective discrimination of protective devices

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

icebreaker icebreaker A C G GE Lighting 2D lamps are fitted as standard. I44

Service Entrance Methods

Installation Instructions

LIEBERT APM 3-PHASE UPS: 15-90KVA/KW, 60HZ, VAC, SINGLE & DUAL INPUT - SITE PLANNING DATA

STANDARD SPECIFICATION FOR. LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs DOCUMENT NO: 44LK-5100/E.02/011

PD-Series Ground Fault Circuit Protection

RELIABLE SOLUTIONS in POWER ELECTRONICS. Power Management Instruments RDAT SERIES BATTERY CHARGER / DC RECTIFIER PMI / GESS / KARMET GROUP COMPANIES

SELECT MEMBERSHIP NUMBER Full Installation 75% new and 25% alteration to exsisting

SDM72 Start on Demand Modules

SOLID STATE POWER CONTROLLERS ACL-series AC1-series AC3-series ACF3-series DAC3- series

BHARAT HEAVY ELECTRICALS LIMITED, JHANSI

User Manual Rittal PMC UPS 6kVA

Zone 1 Linear Range - Installation Guide

LED.Commercial 12W LED DD

EdgeLED TM Range. Installation and Operating Instructions EdgeLED TM E1, E7, S1 and S7 Recessed Ceiling Luminaires

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

MODE - Multiple Occupancy Distribution Equipment Selection guide for low voltage indoor distribution up to 500A

Key features. DESIGNS: - Conservator type - Hermetically sealed

Operating Instructions

INSTALLATION & OPERATING MANUAL LIGHT SABER LED SHAFT LIGHTING SYSTEM EN81-20 INNOVATION NOT IMITATION!

10W LED Die Cast Small Rectangle Bulkhead Light

GUIDELINES ON ELECTRICAL SAFETY AT WORKPLACES

LED Emergency Luminaires

TWIN FAN CONTROLLER. Models:- ITC and ITC-DS Maximum load : V 50Hz ~ 9A and V 50Hz 3 ~ 9A

DS DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL

QMB Panel boards Switchboards. 200,000A. short circuit rating. www. ElectricalPartManuals. com

Single Phase Electronic Speed Controllers

Product Installation Document

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

Guidance for Low Voltage Electrical Installations

NEPAL ELECTRICITY AUTHORITY (A Government of Nepal Undertaking)

Circuit Breaker Prepared By :

NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL SYSTEMS AND CONSTRUCTION NQF LEVEL 2 NOVEMBER 2009

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

ECS CONNECTION OF LARGE LV SERVICES TO SECONDARY DISTRIBUTION SUBSTATIONS

PS24/AC Volt AC 16 Amp

OTEC Transfer switch open transition

HR25 Solo. Installation and User Instructions. Through the Wall Heat Recovery Ventilators

Transfer switch OTEC and OTECSE open transition

Demand Switch NEFA20 Plus. Installation Guide. Please read this entire guide before beginning the installation!

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

Doc Ref: WD024/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

PSU EN54-4 Power Supplies

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

InteliCharger V 20A Intelligent Automatic Battery Charger

MESP TECHNICAL SPECIFICATION FOR A STATIONARY CONTROL BATTERY AND CHARGER SET FOR USE IN A SUBSTATION

Installation Manual for D154X Series Multi-Indicator, General Purpose Power Supplies

Medium-Voltage Switchgear and Switches

Series 230 Automatic Transfer Switch

18W Low Energy. instructions. Instructions

Accessories SU200M, SU200MR, and S200UDC UL 489, CSA 22.2 No. 5

SOUTH AFRICAN NATIONAL STANDARD. Plug and socket-outlet systems for household and similar purposes for use in South Africa

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

Synergy WIRING ACCESSORIES / PRODUCT GUIDE

Transfer switch OTEC open or delayed transition

Transcription:

LASERMET MINIATURE LED SIGN POWER AND SWITCH UNIT Installation Instructions PS-LEDS-1W PS-LEDS-RG 00597-53-000 Issue 2 23 August 2010

Introduction The Miniature LED Sign Power and Switch Unit is intended to be used in conjunction with Lasermet s Miniature LED Signs. The Power and Switch Unit accepts a mains input and provides the correct voltage to illuminate the sign. A switch on the unit allows the sign to be turned on and off in the case of one-way signs, and switched between off and the two indications in the case of two-way red/green signs. The unit is usually sited at a convenient position for users to operate the switch and can be wall or desk mounted. The unit is able to power one Lasermet Miniature LED Sign. This equipment is part of a range of interlock systems manufactured and provided by Lasermet. Other products include control systems, interlock switches, laser shutters, door locks, access signs, external power supplies etc. which can be connected to provide a complete interlock system. Full support, design and installation is available from Lasermet, please contact us for any queries. Contact details are given at the end of this manual. 00597-53-000 Page 2 of 6 Issue 2 23 August 2010

Installation The Power and Switch Unit is capable of operating one Lasermet LED Miniature Sign. The unit is designed to be permanently attached to a wall or other fixed vertical surface. It should be mounted in a convenient position for use and wiring. Normally it is wall-mounted on the inside of the entry door of the controlled area. During installation, fixed wired connections will need to be made from the Power and Switch Unit to the incoming mains supply and the Miniature LED Sign. A Ø20mm conduit hole is provided and allowance should be made for the installation of electrical conduit to make entry to the bottom of the unit. Refer to Figure 1 for details of the fixing holes and cable entry. Secure the unit to the wall using suitable screws and wall plugs according to the type of wall. Remove the plug from the bottom of the unit and attach the conduit. 49 mm 54 mm Conduit Entry Figure 1: Fixing Centres 00597-53-000 Page 3 of 6 Issue 2 23 August 2010

Wiring The unit is factory configured for 110Vac input for US customers and 220-240Vac for UK and European customers. The mains supply to the unit should incorporate a double pole isolator and overcurrent protection of a 3A or 5A circuit breaker or a 3A fuse. An earth connection is not required. Electrical installation must comply with local wiring regulations. The incoming and outgoing wires share a common conduit, therefore the cable to the sign should have an insulation rating which exceeds the mains supply voltage. Unscreened 7/0.2mm cable approved to DEF STAN 61.12 parts 4 and 5 is recommended. One-way signs require two-core cable, Red/Green signs require three cores. A two-way terminal block is provided for the incoming mains supply. A three-way terminal block is provided for connection to the sign. In the case of PS- LEDS-1W, the GN+ terminal is inoperative and is unused. The connections for the One-Way Warning Sign with PS-LEDS-1W are shown in figure 2 on the next page. The connections for the Two-Way Red/Green Warning Sign with PS-LEDS-RG are shown in figure 3. 00597-53-000 Page 4 of 6 Issue 2 23 August 2010

Power and Switch Unit Lasermet 1-Way Miniature Warning Sign RD+ - GN- J1 Green - Green + L N MAINS INPUT No Connection LIVE NEUTRAL Incoming Mains Supply Figure 2: Wiring for 1-Way LED Sign Power and Switch Unit Lasermet Miniature Warning Sign RD+ - GN- J1 Red - Red + Green - Green + L N MAINS INPUT LIVE NEUTRAL Incoming Mains Supply Figure 3: Wiring for 2-Way Red/Green LED Sign 00597-53-000 Page 5 of 6 Issue 2 23 August 2010

Specifications Dimensions: 72 mm wide X 78mm high X 64mm deep. Weight: 300g. Input: 220-240Vac or 110-120Vac 50-60Hz. Power Consumption: 6W. Output: 24VDC nominal 250mA maximum. All figures quoted are approximate. Lasermet reserve the right to alter specifications without prior notice. Contact Details For sales and technical support:: Lasermet Ltd. Lasermet House, 137 Hankinson Road, Bournemouth BH9 1HR United Kingdom. Tel.: +44 (0) 1202 770740 Fax: +44 (0) 1202 770730 E-mail: Website: sales@lasermet.com www.lasermet.com 00597-53-000 Page 6 of 6 Issue 2 23 August 2010