Installation, Operation, Repair and Parts Manual

Similar documents
ARAG Modular Manual Valve Operating Instructions and Parts Manual

ARAG Modular Electric Valve Operating Instructions and Parts Manual

Installation, Operation, Repair and Parts Manual

100 Gallon Skid Sprayer

Installation, Operation, Repair, and Parts Manual

Models 9910-DP423 and 9910-DP423GRGI

For a 25 Amp Circuit with a 10% Voltage Drop, we recommend the following [but please follow all local electrical codes]: 50 [15.2] 8 [8.

100 Gallon Skid Sprayer

High Pressure Diaphragm Pumps

100 Gallon 4- Wheel Sprayer

Cleanload Chemical Eductor

Installation Manual for the SHURflo LCB - G Pump Controller

Low Pressure Diaphragm Pumps

Installation, Operation, Repair and Parts Manual

9047C, 9047C-SP, and 9047C-BSP

Installation, Operation, Repair and Parts Manual

Installation, Operation, Repair and Parts Manual

Cleanload Chemical Eductor

50 Gallon Skid Sprayer

Maintenance Instructions for All Models

150 Gallon 3- Point Hitch Sprayer

Original Instruction Manual

High Pressure. Diaphragm Pumps (12/12, Rev. C)

INDUSTRIAL PUMP 8000 SERIES

INDUSTRIAL PUMP 8000 SERIES

Installation, Operation, repair and Parts Manual

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

9243P-SP Pedestal, Self-priming, Polypropylene Transfer Pumps

Series 7560 Hydraulically-Driven Roller Pumps

ARAG Foam Marker Operating Instructions and Parts Manual

Low Pressure Diaphragm Pumps

Operator s Safety and Service Manual

Medium Pressure Diaphragm Pumps

Medium Pressure Diaphragm Pumps

Operator s Safety and Service Manual

Installation, Operation, Repair Instructions

Model 2535S and Model 2545S

Installation, Operation, Repair, and Parts Manual Description. Hydraulic Motor. Requirements. 1 2" NPT input, 3 8" quick disconnect output

PARTS AND INSTALLATION MANUAL

3-POINT SPRAYERS. Operation, Service & Parts Manual For G50E. FORM: G50EBook.QXD

GARDEN HOSE UTILITY PUMP

ProFlo FatBoy

Bronze Plate-Mount Rotary Close-Coupled External Gear Pumps

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Shurflo NSF Commercial-Duty Filter and Rendering Close-Coupled Roller Pumps

High Pressure Diaphragm Pumps

Pressure Roller with 24-inch Fixed Extension - For application of architectural paints and coatings -

Operating and Installation Instructions

Series 2100 Diaphragm

AUTOMATIC SUBMERSIBLE UTILITY PUMP

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

Installation, Operating and Maintenance Manual

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

Series 5200 Big Twin Piston Pumps. Installation, Operation, Repair and Parts Manual

SUNC3000 / Item #40885

HYDRAULIC POWER PACK

Hydraulically-Driven Pressure Washer Models 1802C, 1803C, 1804C, 1805C, 1806C, 1807C, 1824C, 1825C, 1826C and 1827C Form L-0560PW

Installation Manual DIAPHRAGM WELL TANK

Carbonator-Mount Rotary Close-Coupled External Gear Pumps

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

SOLAR ELECTRIC SUBMERSIBLE PUMP D.C. POWERED OWNERS MANUAL

SUBMERSIBLE PUMP. Model ASSEMBLY AND OPERATING INSTRUCTIONS

Medi-Flow. Model M101 & M101D Medicator Instructions GETTING TECHNICAL ASSISTANCE

Owner s Manual GLASSLINED PUMP TANK

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps

Bertolini Sprayer Operator s Manual

Manual Concentrate Management System

Bronze Close-Coupled Self-Priming Flexible Impeller Pumps

MR 5-30 Aviation Fuel Meter Owner s Manual

SOLAR ELECTRIC SUBMERSIBLE PUMP D.C. POWERED OWNERS MANUAL

Installation, Operation, Repair And Parts Manual

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

INSTRUCTIONS PARTS LIST This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE

NECO Pumping Systems

MGFHVLP. Instructions/Parts. Mini Gravity Feed System E. Part No Includes MGFHVLP Mini Gravity Feed Spray Gun and MGC 125 Gravity Cup.

SUBMERSIBLE SUMP PUMPS

StormPro BA Series Sump Pump

8" - 12" Hydraulic Steel Squeeze Off Tool

P-200 Plastic Utility Pump for Petroleum Products

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

Air Operated Diaphragm Pumps Operating and Maintenance Instructions

Model , Series A 9 in. (23 cm) roller frame with 45 angle and 12 in. reach 1/2 in. (13 mm) nap roller cover

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

ESE Series Cast Iron Sewage Pumps

STOP. LP-50DEF-BRL Lever Hand Pump System Barrel Mounting. Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

READ THIS MANUAL CAREFULLY BEFORE USING THE SPECK PUMP

Zip-Tex Spray Gun. Instructions A. Model psi (0.86 MPa, 8.6bar) Maximum Working Pressure

INSTRUCTION MANUAL G-Surge Tank #40007, #40008 & #40009

DIRECT-DRIVE PRESSURE WASHERS

SUBMERSIBLE SUMP PUMPS

FP0S2300X FP0S3000X. Submersible Waterfall/Utility Pumps OWNER S MANUAL. Call Installation/Operation/Parts. English...

P239-1 Supply Pumper Instructions

Spray Nozzle Adapters

DP-139 PUMP DIMENSIONS

Voltmaster Centrifugal Trash Pumps

PowerFLO 5800/5900 Series

Transcription:

Self-Priming Adaptor Form L-1516 (3-08) Installation, Operation, Repair and Parts Manual Description Self-priming adaptor (SPA) is a low pressure tank that provides air separation from the liquid being pumped. Air is vented out the top port and liquid is redirected from the lower port back to the centrifugal pump inlet port. Recirculation through the centrifugal pump provides fast self-priming of the inlet vacuum hose to the centrifugal pump. 1530-0024S Material:...304 Stainless Steel Volume:...8.7 Litres (2.3 US Gallons) Max Pressure:...3 Bar (45 PSI) Ports:...2" NPT Inlet 2" NPT Vent 1-1/4" NPT Return 1530-0025S Material:...304 Stainless Steel Volume:...8.7 Litres (2.3 US Gallons) Max Pressure:...3 Bar (45 PSI) Ports:...1-1/2" BSPP Inlet 1-1/2" BSPP Vent 1-1/4" BSPP Return

General Safety Information Notes are used to notify of installation, operation, or maintenance information that is important but not safety related. Caution is used to indicate the presence of a hazard, which will or may cause minor injury or property damage if the notice is ignored. Warning denotes that a potential hazard exists and indicates procedures that must be followed exactly to either eliminate or reduce the hazard, and to avoid serious personal injury, or prevent future safety problems with the product. Danger is used to indicate the presence of a hazard that will result in severe personal injury, death, or property damage if the notice is ignored. Do not pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc. Do not use in explosive atmospheres. The pump should only be used with liquids compatible with the pump materials. Failure to follow this notice may result in severe personal injury and/or property damage and will void the product warranty. The sound pressure level of the pump may exceed 80dBA. Observe all safety precautions when operating the pump within close proximity for extended periods by wearing hearing protectors. Extended exposure to elevated sound levels will result in permanent loss of hearing acuteness, tinnitus, tiredness, stress, and other effects such as loss of balance and awareness. Do not pump at pressures higher than the maximum recommended pressure. Operate the pump between a temperature range of 45 to 140 F [7 to 60 C]. Make certain that the power source conforms to the requirements of your equipment. Provide adequate protection in guarding around the moving parts such as shafts and pulleys. Disconnect the power before servicing. Release all pressure within the system before servicing any component. Drain all liquids from the system before servicing. Secure the discharge line before starting the pump. An unsecured discharge line may whip, resulting in personal injury and/or property damage. Check all hoses for weak or worn condition before each use. Make certain that all connections are tight and secure. Periodically inspect the pump and the system components. Perform routine maintenance as required (See Maintenance). Use only pipe, hose, and hose fittings rated for maximum rated pressure of the pump or the pressure at which the pressure relief valve is set at. Do not use used pipe. Do not use these pumps for pumping water or other liquids for human or animal consumption. Hazardous Substance Alert 1. Always drain and flush pump before servicing or disassembling for any reason (see instructions). 2. Always drain and flush pump prior to returning unit for repair. 3. Never store pumps containing hazardous chemicals. 4. Before returning pump for service/repair, drain out all liquids and flush unit with neutralizing liquid. Then, drain the pump. Attach tag or include written notice certifying that this has been done. It is illegal to ship or transport any hazardous chemicals without United States Environmental Protection Agency Licensing. 2

Plumbing Installation Mount self-priming adaptor in a secure location. Optional bracket kit available, PN 3430-0700. Max. SPA Height: Top of SPA no higher than bottom of fill port. Min. SPA Height: Top of SPA mounted higher than top of casting on inlet port to support gravity feed system. Max. Hose Distance: Hose length between SPA and pump inlet should be no more than three meters (10 ft.). Vent Line minimum diameter: 25mm (1 in.) diameter raised a 1/2 meter (20 in.) above SPA before entering tank. Use clear hose if possible as indicator for priming. Return Line: Return line is subject to suction vacuum pressure. Use hose rated for vacuum pressure of discharge -75 cm (-30 inches) Hg. Minimum Height Max. Height Min. Height 1/2 meter (20 Inches) Mount self-priming adaptor in a location within 3 meters (10 ft.) of the pump inlet. The self-priming adaptor chamber is rated as a low pressure tank and is not designed to accept pressures over 3 Bar (45 PSI). System should be plumbed to protect from over-pressurization. Use of two-way and/or three-way valves can be used to direct flow through the self-priming adaptor (SPA) during priming operation. The vent line can be sized to be used to fill the tank once the pump has primed. Use 32 mm (1-1/4 in.) max ID vacuum hose for return line from the SPA to the pump inlet port. Directing circulation flow from SPA directly towards pump inlet impeller eye will greatly increase overall priming performance and stability. The return line from the SPA to the pump inlet must be hose rated for vacuum pressure. Vent Line Circulation Line Product Line Fill Port SPA Tank Return Line 3

MANIFOLD SYSTEMS PLUMBING Plumbing Installation Fill Port Solution Tank Circulation Line Vent Line & Fill Line to Tank To Boom SPA Return Line Manifold systems will function well with SPA. It is important to direct the return line from the SPA to the pump inlet in a manner as to jet the flow into the pump impeller to ensure good priming performance and stability. Use of Y fittings at the inlet of the pump will aid in accomplishing a positive flow towards pump impeller. To ensure that the fluid necessary to induce priming does not cascade out of the system, be sure that all other systems are turned off during priming (boom, agitation, chemical eduction). Operation and Maintenance To facilitate pump priming, water or fluid is circulated through eye of the impeller and pump. The attached SPA allows for entrained air to percolate out of the liquid being circulated and releases the air back to atmosphere through the vent line. The liquid is returned back to the pump inlet, thereby evacuating the inlet suction line of air. Once the pump is primed, pressure increases in the separation chamber. The operator then closes off the circulation path to the pump inlet and SPA and redirects the pump flow to fill sprayer tank. The vent line can also be used to complete the circuit for filling the sprayer tank. In many systems, the vent line provides an efficient path to the tank and greatly decreases the amount of time to fill the tank. If the vent line is used to fill the tank, the return line is shut off once the inlet fill line is primed. To operate the pump in spray mode, close off self-priming circuit and fill line, then open tank valve. Tank Vent Line & Fill Line to Tank To Boom Fill Line Return Line SPA 4

Operation and Maintenance A simple way to test the system is to insert a vacuum gauge on the fill port to measure the amount of vacuum the pump is producing. When the pump is running, and water is being circulated through the SPA, a reading of -63 to -75 cm (-25 to -30 inches) of Hg vacuum pressure is expected. Simply placing your hand over the inlet port will also give a good indication of operation. Pump speed can also increase priming rates. Speed of pump should operate in the range of 3500 to 5000 RPMs to get good results. Having a clear vent line and return line hose can be a good indicator for how the SPA is working and when priming is achieved. Simply listening to the pump operation will also indicate when priming has occurred; a sudden change in RPM is associated with pump flow when the pump is primed. Troubleshooting Guide Symptom Probable Cause(s) Corrective Action Pump fails to prime. No liquid or low liquid level for water circulation to induce priming. Valves are not open to provide path for water circulation through priming system. Open clean water tank valve to fill priming circuit with adequate water to operate priming circuit. Water will flow out vent line or fill port if filled to an adequate level. Check valves to make sure they are in correct position for priming. Vacuum leaks. Check that valve to tank is closed and valve on fill line is open. Pump operating speed too low. Increase pump speed (4000 to 5000 RPM). Surging during priming. Low liquid level in SPA. Crack open clean water tank to fill tank and priming circuit to acceptable liquid level. Too much air is returning with liquid to pump short-circuiting priming. Reduce liquid flow back to pump by reducing return line by one size ID. Pump operating speed too high. Reduce pump speed during priming. Vacuum decreases over time during priming operation. Water for priming is initially adequate but cascades away from priming circuit. Check to make sure water is not finding another discharge path, such as agitation or to boom. 5

Dimensions Self-Priming Adaptor 1530-0024S Self-Priming Adaptor 1530-0025S Mounting Bracket Kit 3430-0700 (Bracket Only Shown 1520-0102) 6

Performance 9305 Series 9303 Series 9306 Series 9307 Series Priming rates are dependent on optimal plumbing systems, length and size of inlet hose, and rotational speed of pump impeller. Actual rates may vary depending on system configuration. Comparison test results were produced in lab under controlled environment. Total lift capacity of pumps is expected to be 7.6 meters (25 feet) or more. Because pump is moving water, the system is able to develop 1.7 bar (25 PSI) pressure against any restriction in vent line during priming at no lift and.34 bar (5 PSI) pressure at 7 meters (23 feet) of lift. 7

Limited Warranty on Hypro/SHURflo Agricultural Pumps & Accessories Hypro/SHURflo (hereafter, Hypro ) agricultural products are warranted to be free of defects in material and workmanship under normal use for the time periods listed below, with proof of purchase. - Pumps: one (1) year from the date of manufacture, or one (1) year of use. This limited warranty will not exceed two (2) years, in any event. - Accessories: ninety (90) days of use. This limited warranty will not apply to products that were improperly installed, misapplied, damaged, altered, or incompatible with fluids or components not manufactured by Hypro. All warranty considerations are governed by Hypro s written return policy. Hypro s obligation under this limited warranty policy is limited to the repair or replacement of the product. All returns will be tested per Hypro s factory criteria. Products found not defective (under the terms of this limited warranty) are subject to charges paid by the returnee for the testing and packaging of tested good non-warranty returns. No credit or labor allowances will be given for products returned as defective. Warranty replacement will be shipped on a freight allowed basis. Hypro reserves the right to choose the method of transportation. This limited warranty is in lieu of all other warranties, expressed or implied, and no other person is authorized to give any other warranty or assume obligation or liability on Hypro s behalf. Hypro shall not be liable for any labor, damage or other expense, nor shall Hypro be liable for any indirect, incidental or consequential damages of any kind incurred by the reason of the use or sale of any defective product. This limited warranty covers agricultural products distributed within the United States of America. Other world market areas should consult with the actual distributor for any deviation from this document. Return Procedures All products must be flushed of any chemical (ref. OSHA section 1910.1200 (d) (e) (f) (g) (h)) and hazardous chemicals must be labeled/tagged before being shipped* to Hypro for service or warranty consideration. Hypro reserves the right to request a Material Safety Data Sheet from the returnee for any pump/product it deems necessary. Hypro reserves the right to disposition as scrap products returned which contain unknown fluids. Hypro reserves the right to charge the returnee for any and all costs incurred for chemical testing, and proper disposal of components containing unknown fluids. Hypro requests this in order to protect the environment and personnel from the hazards of handling unknown fluids. Be prepared to give Hypro full details of the problem, including the model number, date of purchase, and from whom you purchased your product. Hypro may request additional information, and may require a sketch to illustrate the problem. Contact Hypro Service Department at 800-468-3428 to receive a Return Merchandise Authorization number (RMA#). Returns are to be shipped with the RMA number clearly marked on the outside of the package. Hypro shall not be liable for freight damage incurred during shipping. Please package all returns carefully. All products returned for warranty work should be sent shipping charges prepaid to: HYPRO Attention: Service Department 375 Fifth Avenue NW New Brighton, MN 55112 For technical or application assistance, call the Hypro Technical/Application number: 800-445-8360, or send an email to: technical@hypropumps.com. To obtain service or warranty assistance, call the Hypro Service and Warranty number: 800-468-3428; or send a fax to the Hypro Service and Warranty FAX: 651-766-6618. *Carriers, including U.S.P.S., airlines, UPS, ground freight, etc., require specific identification of any hazardous material being shipped. Failure to do so may result in a substantial fine and/or prison term. Check with your shipping company for specific instructions. Printed in USA Hypro 2011 SPRAY & INJECTION TECHNOLOGIES GROUP 375 Fifth Avenue NW New Brighton, MN 55112 Phone: (651) 766-6300 800-424-9776 Fax: 800-323-6496 www.hypropumps.com