Flow meters, Flow switches and Flow transmitters

Similar documents
UNIVERSAL Flow Meters

Flow meters, Flow switches and Flow transmitters

Flow meters, Flow switches and Flow transmitters

Flow meters, Flow switches and Flow transmitters

G2 Industrial Grade Meters

Pressure Instrument Testing Equipment

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

KDM ARMORED FLOW METER & SWITCH

E. Clark & Associates 10 Brent Drive Hudson, MA Tel. 978 / Fax 978 / Two Switch Output Hex Screw Adjustment

UNIVERSAL. Flow Monitors Inc. INSITE Series PX - IS - TX Flow Rate Indicators and Switches

DW PADDLE-BELLOWS FLOWMETER & SWITCH

NBK-M - Economical Level Indicator

DW PADDLE-BELLOWS FLOWMETER & SWITCH

Product Information Page

Industrial Meter Catalog

Series 105 Simplex Strainer Cast Iron Swing Bolt O-Ring Closure, Flanged Connection Class 125 ANSI Flat Face Flange Rating VENT 'A' FLOW

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

digital flow meters BW Digi-Meter F-1000

BASIC IN-LINE LIQUID FLOW RATE MONITORS. Data Sheet No. B-699. Select from aluminum, brass or stainless steel to meet system and liquid requirements.

Glass Tube Full-View Flowmeters

DIAPHRAGM SEALS. MHP SERIES MINI HIGH PRESSURE Mini diaphragm seal for pressures up to 6000 psi

DW PADDLE-BELLOWS FLOWMETER & SWITCH

UNITED ELECTRIC 100 Series, Pressure, Vacuum, Diff. Pressure & Temp. Switches Adjustable Ranges 30 Vac to 5000 PSI, -180 to 650 o F

Adjustable Dead Band Pressure Switches

TELEDYNE HASTINGS INSTRUMENTS

M Series. Feature rich flow meter and switch with in-line. flow

King Instrument Company opened its doors in 1983 with one major goal:

Ar-Mite TM Low Flow Armored Flowmeter

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 120

Valve Position Monitors

Adjustable Dead Band Pressure Switches

Liquid Turbine Flowmeters

M-200 Series. High flow, Adjustable flow switch with right-angle flow

OMP POSITIVE DISPLACEMENT FLOWMETERS

INDUSTRIAL DYNAMICS CO

Low Pressure Filters

SPANS AND RANGES. Lower Range Limits 150 in. H 2 O ( 38 kpa) 800 in. H 2 O ( 200 kpa)

Liquid Turbine Flowmeters

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 124

TYPE MP OSCILLATING PISTON FLOWMETER

LF/LFM - Low Pressure High Flow Assemblies LF flow rate to 560 lpm, 150 gpm / LFM flow rate to lpm, 4500 gpm.

INDUSTRIAL METER CATALOG version seven

MINI-NBK ECONOMICAL LEVEL INDICATOR

Variable Area Flowmeters VA Master TM Indicating Flowrator Meters 10A4500

J 6 Se r i e s. Pressure and Vacuum switches. features

LOW PRESSURE FILTERS RF Series In-tank / Inline Filters 360 psi up to 400 gpm

Flow-Alert Flow Switches (Micro Switch)

PISTON STYLE GAUGE. Mid-West Instrument

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 123

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

PISTON STYLE GAUGE. For Installation and Operation Manuals Please Visit: Mid-West Instrument

F-2700 SERIES INSERTION VORTEX FLOW METER

BULLETIN NO.ELEC IM240/11A Supersedes IM240/10A

DPT TARGET TYPE FLOWMETERS

PIC-V Valve... 1 Unimizer (1/2 to 3 )... 2 Unimizer (4 to 6 )... 3 Automizer... 4 MVP Valve... 5

F-2700 SERIES INSERTION VORTEX FLOW METER

Brooks GT1000 Series. Industrial Glass Tube Variable Area Flowmeters. GT1000 Series. Data Sheet DS-VA-GT1000-eng January, 2008

Mid-West Instrument. Diaphragm Type Differential Pressure Gauge & Switch Model 130. Shown here with Range 0-5 H2O

Model Connections Max. Flow Range (H 2 O) 10A A3220 Horizontal ¼ NPT 100 l/h. 10A3225/55 Vertical ¼ NPT 100 l/h. Vertical 1 NPT Vertical 1 G

Glass Tube Flowmeter Model GT1000

F-1500 SERIES INSERTION TURBINE FLOW METER

Electric Actuated Ball Valves 150# Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe

Product Summary. Flow Meters. Hydraulic Diagnostic Products

Dual Hi-Lo Pressure Switches

DOUBLE, P.O. CHECK VALVES (PRE-ENGINEERED BLOCKS)

Pressure Controller. Cataloge K Code Characteristics Index. K00-2 Pressure Controller Brief Introduction

MEMFlo MFTV METAL BODIED FLOW METER WITH CLEAR TOP

Size: 1/4 to 3. Material: 316 Stainless Steel, Carbon Steel,

Quartz. Save Space with Low Profile Design

Variable Area Flowmeters Armored Purgemeter

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

Double Acting & Spring Return. SERIES 92/93 Rack & Pinion PNEUMATIC ACTUATOR. The High Performance Company

Mid-West. Instrument ELECTRICAL DIVISION 1 LOCATIONS:

Low Profile Insertion Vortex

KENCO ENGINEERING COMPANY

KEL DIFFERENTIAL PRESSURE FLOWMETERS

ISTEC MAGNETIC METERS

Actuated Valves PRICING

M3500 Industrial Pressure Transmitter

Transmitting Transducer. Gas/Air Velocity Range:

BULLETIN OCTOBER DeZURIK ROTARY DIAPHRAGM ACTUATORS

Turning Ideas Into Engineered Solutions FILTRATION GROUP

Electric Actuated Ball Valves 3-piece Stainless Steel, Full Port 1/4 to 3 NPT

6" Steel Model G6. Smith Meter Rotary Vane PD Meters. Features. Operating Specifications Maximum Flow Rate. Options

Liquid Turbine Flowmeters

Lower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS).

CRANE Limit Switches. CCR Series. CXA Series. CCA Series

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

ivp PROGRAM FNW Ball Valves

General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s. High Temperature MgO Elements (RA)...

BARTON 7400 Precision Gas Turbine Flow Meters

Low Pressure Filters. Low Pressure Filters LOW PRESSURE FILTERS

Series M and MA Positive Displacement Flow Meters

OMP Positive Displacement Flowmeters

Dissolved Oxygen Measurement System with Air Blast Cleaner

Dual Hi-Lo Pressure Switches

mass flowmeter for compressed air

North American Y-Type Strainers for Gas, Oil, Oxygen, Steam

Transcription:

MAX FLOW SIZES FROM 80 TO 500 GPM (300 TO 1800 LPM) MAX LIQUID PRESSURE 300 PSI (20.69 BAR) LN SERIES MAX LIQUID PRESSURE 1000 PSI (68.97 BAR) LE SERIES Flow meters, Flow switches and Flow transmitters A Large Vane Style For Liquids 45 NIST CSA Certified NRTL/C CE Marked (as noted) Traceable Calibration Certificate Available DESCRIPTION CALIBRATION These variable-area flow meters have a spring-loaded swinging vane. Mounting is in-line and in any position. Straight pipe runs, before or after the meter, are not required. The all-mechanical sensing system directly drives the pointer, switches and transmitters. This swinging vane can be manually operated with a wrench (factory supplied) to verify or adjust switch points or to free the vane should it become lodged by debris in the fluid. READOUTS The flowmeter has outputs both visual and electronic. Visual displays are either pointer (with inscribed scale) or numeric. Signal outputs can be mechanical switch closure, 4-20 ma analog or both (for signal redundancy). The switches can be general purpose or rated for hazardous locations (all classes, groups and divisions). The 4-20 ma transmitters are Intrinsically Safe if used with approved barriers. All flow meters are individually calibrated for fluids with the viscosity you specify (up to 3000 SSU/660 Centistokes). We also compensate for your fluid s specific gravity. For NIST Traceability please consult factory. CONSTRUCTION MATERIALS The meter body, internal moving parts, and seals are offered in a variety of materials to suit a wide range of applications: water, synthetic and petroleum based oils, paint, some corrosives, solvents, air and gases. See selections in the How to Order section. LINE CONNECTION Ports can be from 1-1/2 to 4 inches. All connections and types are specified in the How to order section. D A B E Fluid enters at A, passes around the semi-circular vane B, exits at outlet C. The vane resists the flow because of the spring D. The further the vane is pushed the larger the passageway E becomes. This minimizes pressure drop. The vane shaft turns to operate the pointer F and remote signal devices such as the switch G. F C G LN Series LN081512 1 Viton and Kalrez are registered trademark for DuPont Performance Elastomers.

HOW TO ORDER Select appropriate symbols and build a model code number, as in example shown: EXAMPLE: LN - F S F 2ØØGM - 2Ø - 32V1.Ø - SERIES BY PRESSURE RATING Normal pressure (300 PSI) = LN High pressure (1000 PSI) = LE HOUSING MATERIAL WHERE USED Aluminum Lube oil = D Aluminum (hard coated) Lube oil with exterior corrosion protection = E Brass Water = F Cast iron Oil = C Cast iron, nickel plated Water, oil with exterior corrosion protection = N Aluminum with brass center section Water = Q Carbon steel Oil = M Stainless steel (316) Chemicals, corrosives = I Carbon steel, nickel plated Water, oil with exterior corrosion protection = J LN LE or LN INTERNAL MOVING PARTS Stainless steel (300 series) Standard for water, oil = S Stainless steel (316 series) Chemicals and corrosives = I SEAL MATERIAL Buna N Water, oil = B EPR Hot water, caustics = E Viton Acids, some caustics = F Kalrez (dynamic) & Buna N (static) Specialty = A Kalrez (dynamic) and EPR (static) Specialty = H Kalrez (dynamic) and Viton (static) Specialty = K Kalrez (dynamic) and Teflon (static) Corrosives, solvents = T Not available with A, B or W "Housing Materials" MAX FLOW RATE LIQUIDS GPM 8Ø, 1ØØ, 15Ø, 2ØØ, 3ØØ, 4ØØ*, 5ØØ* = GM LPM 3ØØ, 4ØØ, 6ØØ, 8ØØ, 12ØØ, 15ØØ*, 18ØØ* = LM CMH 4Ø, 5Ø, 7Ø, 9Ø*, 12Ø* = CMH *Requires special option DS. PORT CONNECTION Threaded Socket-Weld ANSI SAE-Style SAE-Style Style Max. Flow Flanges Flanges Flanges (GPM) (LPM) (NPT) (Pipe) Inches MM 1-1/2 38.10 = 12 = 12W = 12F 100 378 2 50.80 = 16 = 16W = 16F 150 567 2-1/2 63.50 = 2Ø = 20W = 20F 300 1134 3 76.20 = 24 = 24W = 24F 400 1512 4 101.6 = 32 = 32W = 32F 500 1890 Flanges are steel; stainless steel units have stainless steel flanges. ANSI flanges also available. FLUID CHARACTERISTICS Viscosity number followed by a V (for SSU), C (for centipoise), or CS (for centistokes) followed by the specific gravity. Example: 32V1.Ø would indicate a fluid with a viscosity of 32 SSU with a specific gravity of 1. For dual viscosities (where there is a start up viscosity or where there may be a range) put in both values with a slash. Example: 32Ø/15ØV.9. 2 LN Series LN081512

SERVICE Weatherproof (Type 4) Available on all boxes = W Weatherproof, corrosion proof (Type 4X) Available on all boxes = X RX1 W L - ST - 3ØD FLOW DIRECTION Left to right = R Right to left = L Up = U Down = D SPECIAL OPTIONS High-temp- 400 F for A & R Box, 300 F for transmitter options = HT Stainless steel ID tag for customer supplied information = ST Pin connector (See explanation for special options.) = PC CSA enclosure / PVC window = C Tempered glass window = TG Dual spring (for higher flows) = DS SWITCH SETTING No symbol = Lowest possible setting (usually 10% of maximum flow) Desired set point is assumed to be in flow units already selected (GPM). Give flow rate 3ØD followed by a D for flow going down (flow failure) or a U for flow going up. Example, 3ØD indicates a setting of 30 GPM in declining flow. CONTROL BOX & READOUT Basic Features These options all include inscribed scale and pointer plus one of the standard (non hazardous location) switches selected to the right. These options all contain inscribed scale with pointer plus hazardous location switches selected to the right. Note that the box is not rated, only the switches. Additional Options No switch One SPDT (3 wire), CE One high vibration SPDT (3 wire), CE Two SPDT (3 wire), CE Two high vibration SPDT (3 wire), CE One SPDT (4 wire) Two SPDT (4 wire) One SPDT (3 wire) high temperature Two SPDT (3 wire) high temperature One SPDT (3 wire) gold contact Two SPDT (3 wire) gold contact One SPDT hazardous location One DPDT hazardous location Two SPDT hazardous location Two DPDT hazardous location One SPST hazardous location proximity Two SPST hazardous location proximity High resolution Separate junction boxes pointer and (with terminal strips) inscribed scale for switch & transmitter R Box T Box Materials of Construction Aluminum Aluminum RØ R1 R1B R2 R2B R3 R4 R61 R62 R71 R72 R7 R17 R18 R19 R3Ø R31 These options all contain a 4-20 ma transmitter and one of the selections to the right. No switches (Instrinsically safe with barrier) RXØ TXØ One SPDT (3 wire), CE RX1 TX1 Two SPDT (3 wire), CE RX2 TX2 One SPDT (4 wire) RX3 TX3 Two SPDT (4 wire) RX4 TX4 One SPDT (3 wire) high temperature RX61 TX61 These options all include a 4-20 ma transmitter with a digital LCD display plus one of the selections to the right. No switches One SPDT (3 wire), CE One SPDT (4 wire) One SPDT (3 wire) high temperature TXLØ TXL1 TXL3 TXL61 LN Series LN081512 3

CONTROL BOX SELECTION GUIDE Standard Offering: Control Box R R box is selected for greater resolution (more increments on the inscribed scale). It holds switches (general purpose and hazardous location all classes groups and divisions) and 4-20mA transmitter. Switch (standard service) and transmitter are offered in this control box together when signal redundancy is desired. You get this control box when you order any CONTROL BOX & READOUT starting with an R (see "How to Order" page). Examples: R1WR is a one switch, weatherproof box with flow from left to right. This control box is made from epoxy coated aluminum. 14.19 7.63 8.75 12.94 PORT TO PORT 19.56 (4 SPINGS for FLOW RATES GREATER THAN 300 GPM, 1200 LPM, or 70 CMH) 18.28 (2 SPRINGS) 9.44 5.13 10.44 REF 5.31 1/2" NPT CONDUIT CONNECTION BOX TYPES RP, RT, RTV, & RTZ R8.88 APPROX. SWING RADIUS R10.16 APPROXIMATE SWING RADIUS 400 and 500 GPM Special Offering: Control Box T T box is selected for availability of two isolated junction boxes with terminal strips. This means that no direct wiring to switches or transmitters is required. Digital LCD display of flow is optional ( TXL ). It holds switches (general purpose) and 4-20mA transmitter. Switch (standard service) and transmitter are offered in this control box together when signal redundancy is desired. These are wired to separate junction boxes for signal isolation. You get this control box when you order any CONTROL BOX & READOUT starting with a T (see "How to Order" page). Examples: TX1WR is a one switch with 4-20mA transmitter, weatherproof box with flow from left to right. This control box is made from epoxy coated aluminum. 14.19 12.94 PORT TO PORT 20.27 (4 Springs for flow rates greater than 300 GPM, 1200 LPM, or 70 CMH) 18.99 (2 Springs) 10.15 10.25 REF 5.13 R8.88 APPROXIMATE SWING RADIUS. R10.16 APPROXIMETE SWING RADIUS. 400 and 500 GPM. 4 LN Series LN081512

SPECIAL OPTIONS High temperature: (option HT) requires seals of Viton, EPR, Kalrez or Teflon (compatible with fluid). A thermal barrier (heat-resistant cloth) is added between the housing and the control box, which must be used with service option "W" (weatherproof) or "X" (corrosion resistant). A metal scale is provided. Identification tag: (option ST) customer-supplied information is stamped on a stainless steel tag that is attached to the nameplate. Multi-pin connector: Pin connectors (option PC) are available for rapid field installation. Meters are provided with the male half of either a micro or a mini pin connector. Check the chart below for the number of pins required for your control box selection and current type. Insert the number of pins in the code PC for a mini connector or PC M for a micro connector. For example, a PC5 would be a 5 pin mini and PC5M would be a 5 pin Micro. (See table below for number of pins required for each option.) CE marked switches: (option CE) SPDT 3-wire switch for general purpose use. Standard on switches 1, 1B, 2 and 2B, optional on 3, 4, 61, 62, 71 and 72. Tempered-glass window: (option TG) replaces the standard window. A tempered-glass window is employed where airborne solvents or high-ambient temperatures are common. Number of pins required for various combinations of current type, box type and switch option. AC switch options 1, 1B, 61, 71 3 53 DC switch options 0 1, 1B, 61, 71 3 2, 2B, 54, 62, 72 53 A 3 4 6 5 3 4 Box R 3 4 6 5 3 4 RX 3 TX 3 3 4 3 4 TXL 3 3 4 3 4 *This box allows micro pin connectors only. Eg. PC3M or PC5M. ENGINEERING DATA Maximum fluid temperature: 200 F (95 C) Optional max. fluid temperatures: 300 & 400 F (150 & 205 C) (option HT) Max. ambient temp: 150 F (65 C) CSA listed only to 105 F (40 C) SERIES LN Max. operating pressures (3:1 safety factor): 300 PSI (20.69 BAR) SERIES LE Max. operating pressures (2:1 safety factor): 1000 PSI (68.97 BAR) Readout accuracy, full scale: ±2% FLOW & PRESSURE DROP Meters with maximum flows to 300 GPM (1200 LPM) impose a pressure drop that increases with flow from 1.9 to 3.8 PSI (avg. 2.2). Flows greater than 400 GPM have a maximum pressure drop of 5.5 PSI. With 150 lb R.F. flanges (for other flanges consult factory) Port Size A (inches) 1-1/2 5 2 6 2-1/2 7 3 7-1/2 4 9 "Flow up" or "flow down" dimensions are the same. Scale numbers are turned 90 to be right reading. For additional information on flanged connection see page 129. Universal Flow Monitors, Inc. 1755 E. Nine Mile Road P.O. Box 249 Hazel Park, MI 48030 Tel: 248-542-9635 Fax: 248-398-4274 www.flowmeters.com E-mail: ufm@flowmeters.com LN Series LN081512 5