Lexxi T1660 Time Domain Reflectometer

Similar documents
Users Manual. Phase Rotation Indicator

KMP Insulation-Continuity Tester. Users Manual

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

AIR VELOCITY METER ALNOR MODEL AVM410 AIRFLOW INSTRUMENTS MODEL TA410

PY-11 Voltage & Continuity Tester

Auto-Off & Power Hold Function

Warren G-V Thermal Control Devices

MICROMANOMETER ALNOR MODEL AXD610 AIRFLOW INSTRUMENTS MODEL PVM610

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

Phase Sequence Tester

362 Clamp Meter. Users Manual

323/324/325 Clamp Meter

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

i3000s/i2000 Flex AC Current Probe

i400s Calibration Information Introduction

INSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

362 Clamp Meter. Users Manual

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

PVI 60KW, PVI 82KW, PVI 95KW

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

VELOCICALC Air Velocity Meter

Video & Power Over Coax Kit

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

MARTINDALE MARTINDALE IN2001/IN2003 INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN2001/IN2003 INSULATION & CONTINUITY TESTERS

Ventilation Testing. Micromanometer. Alnor Model AXD610 AIRFLOW TM Model PVM610. Operation and Service Manual

DP-CALC TM Micromanometer

Megohmmeter Test Probe

10 Year Limited Warranty

Model Battery Powered Milliohm Meter

DALI 650mA LED Driver

A Member of the. Integrated Metering Technologies

302+/303 Clamp Meter. Users Manual

User Guide. Model Insulation Tester / Megohmmeter. Introduction

Calibration Manual. Detachable Jaw True-rms Clamp Meter

Indoor Air Quality Meter

IAQ-CALC TM Indoor Air Quality Meter

Chek-A-Cell TM. Instruction Manual Rev A 8/12

Power. On Your Terms.

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

IAQ-CALC TM Indoor Air Quality Meter

365 Detachable Jaw True-rms Clamp Meter

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

650mA Phase Dimmable LED Driver

Table of Contents Title Page No.

Thermaltake Warranty / Support Information

373 Clamp Meter. Users Manual

Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual

DWS404 DWS524 DWS654 DWS684 DWS694. DWS SERIES INSTALLATION/OWNER'S MANUAL Car Audio Speakers

IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL

Before installing your Roush Performance Product(s), read through the entire installation procedure and check to make sure all items are present.

INSTRUCTION MANUAL. 12-Station HD Shop 12V Portable Battery Charger

EAGL 1-Touch Laser Level

233 True-rms Remote Display Digital Multimeter Safety Information

Tachometer. English. Users Manual

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

SOLAR DASH CHARGING SYSTEM USER GUIDE

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

NEUTRALIZATION SYSTEM FOR OPA & GLUTARALDEHYDE MEDI-NEWT. User Manual. Endoscope reprocessing the the way way it it should be be

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

Submersible Pond Pump with UV 800 Gallons Per Hour

4-Hour. Rapid Charger. for AA/AAA NiMH & NiCd Rechargeable Batteries. Owner's Manual

1000mA - 650mA Phase Dimmable LED Driver

INSTRUCTION MANUAL DM5B Fax: (503)

Rotating Vane Anemometer

Operating Instructions

Infrared Thermocouple Probe

END USER TERMS OF USE

Instructions for the following product: CONCRETE MOUNTED JIB BASE

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

Sondes USER GUIDE 90/NUG012ENG/07 ISSUE 7 03/2016

Temperature Probe, Battery (installed), Instruction Sheet, Quick Reference Card and Warranty Card.

INSTRUCTION and OPERATIONS MANUAL. for

INSTALLATION & OPERATION MANUAL

DM1016S INSTALLATION/OWNER'S MANUAL 10" Marine DVC Subwoofer

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs

Harley Davidson FL Touring Current Xtreme

Digital Clock model 75100C

CAPACITOR ACTUATED PORTABLE STARTER CAPS USER GUIDE. INST048 Doc 3.01

Digital Body Weight Scale Model No. EB4074C. Questions or Concerns? (855)

HBC-20 - LED HIGH BAY

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

TBX10A INSTALLATION/OWNER'S MANUAL 10" Sealed Enclosure with Built-in Amplifier

Digital Body Weight Scale

HIGH VOLTAGE DIGITAL AMMETER

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

INSP-3 Wiring Inspection Tester

RU BMS Power Supply and Battery Management System Owners Guide

Users Guide for Ac-sync

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

Thermometer model 00826

Transcription:

Lexxi T1660 Time Domain Reflectometer Operation Manual, Rev 1 Document 90/T1660-OPMAN-ENG/01

Before you begin Thank you for your interest in Radiodetection s LEXXI T1660 cable fault locator. Please read this user manual in its entirety before attempting to use the Lexxi T1660 system. Radiodetection products, including this manual, are under continuous development. The information contained within is accurate at time of publication; however the Lexxi T1660, this manual and all its contents are subject to change. Radiodetection Limited reserves the right to modify the product without notice and some product changes may have taken place after this user manual was published. Contact your local Radiodetection dealer or visit www.radiodetection.com for the latest information about the Lexxi T1660 product family, including this manual. Safety WARNING! Failure to comply with safety warnings can cause serious injury or death CAUTION!: Failure to comply with safety cautions can result in damage to equipment or property This equipment shall be used only by qualified and trained personnel, and only after fully reading this Operation Manual. WARNING! Direct connection to live conductors is POTENTIALLY LETHAL. Direct connections to live conductors should only be attempted by fully qualified personnel using the relevant products that allow connections to energized lines. 2 2017 Radiodetection Ltd

Description The Lexxi T1660 is a Time Domain Reflectometer, also known as a Cable Radar. Electrical pulses are transmitted into a cable, and a portion of the pulse energy is reflected back from cable imperfections. These can be discontinuities (eg cable joints, changes in cable type or the far end of the cable under test) or faults (typically short circuits, open circuits, or high resistance joints). The transmitted pulse and the reflected pulse(s) are shown on the display. The time taken by the pulse to travel to the imperfection and back is a measure of the distance to the fault. The distance is displayed after the cursor is positioned at the start of the reflected pulse. The type of imperfection can be assessed by analysing the displayed waveform. NOTE: The cable must contain at least two conductors or one conductor and screen. The Lexxi T1660 is shipped with a set of 100Ω crocodile clip Twisted Pair connection cables as standard. Optional plug-in modules are also available to optimise measurements on 100Ω twisted pair, 75Ω coaxial, 50Ω coaxial or 25Ω power cable. The power cable test lead is fused and has a blocking filter to allow working on live cables up to 600V rms or peak DC. Velocity of Propagation (VOP) The properties of the cable, mainly the insulation between the two conductors, greatly affect the velocity of the TDR pulses. This velocity is known as the Velocity of Propagation (VOP), or Velocity Factor (PVF). The TDR uses this value to calculate distance, so it is important for this to be as accurate as possible. The Lexxi T1660 can accept user selectable values between 1 and 99% (or the equivalent value in feet or meters per microsecond). The VOP values for some common cable types are: 2017 Radiodetection Ltd 3

Power Paper Oil Filled (PILC) 0.50 to 0.56 Cross linked poly (XLPE) 0.52 to 0.58 Twisted Pair Polyethylene 0.67 Jelly filled poly 0.64 PTFE 0.71 Paper (Pulp 0.083µf/mile) 0.72 Paper (Pulp.072µf/mile) 0.88 Coax Foam Poly 0.82 Air Spaced Coaxial 0.94 Air 0.98 Solid PE 0.67 Keypad Select Left Right Up Down Power/Escape Operation 1. Press to power the Lexxi T1660 on 2. At power on, press any key to continue from the Radiodetection screen 3. Use the and to select from Measurements or Settings then enter by pressing 4 2017 Radiodetection Ltd

4. In Settings, use and to change parameters then press to escape to the main menu 5. Select Measurements to enter the TDR screen 6. Press and to move the cursor 7. Range option is highlighted by default. Press and to change range scale 8. Press to scroll to the other parameters such as impedance and VP%, then press and to change the selected parameter values to match the cable under test 9. To return to the main menu, press Waveforms The display of the Lexxi T1660 shows a launch pulse at the left hand side of the display and a reflected pulse if any cable imperfections are within range (see Description section). Move the cursor so that it is positioned at the start of the reflected pulse. The distance to the imperfection is then displayed in the top right hand corner of the display. Open circuit and high impedance series faults will result in a positive (upward) reflected pulse. Short circuit and low impedance shunt faults will give a negative (downward) reflection. Power down 1. Go to the main menu by pressing 2. Press again for 2 seconds 2017 Radiodetection Ltd 5

Operation with the Blocking Filter NOTE: Refer to the Safety Section at the rear of this Manual The Blocking Filter optional accessory is designed to allow safe use on cables energised at up to 600V ACrms 50/60 Hz or 600V DC, Installation Category III with a maximum prospective system fault current of 46kA. Connection to energised cables should only be carried out by trained personnel. Whenever possible, the power supply to the cable under test should be disconnected. A red neon indicates when the test leads are connected to an AC voltage of greater than 100V p-p. The neon should be treated as a visual indicator only and not as an indicator of hazardous live voltages (see IEC 61010-1, EMC BS/EN 61326-1). Keep hands clear of live conductors when connecting insulated crocodile clips to the cable under test. Always keep fingers behind the crocodile clip protection guards. When using the 33ft (10m) range, best results are obtained by keeping the leads (from the crocodile clips to the filter box) as close together as possible. However, take great care not to short circuit anything while doing this. If any part of the Blocking Filter test lead is damaged, then it must not be used. If a test lead fuse has blown it must be replaced with a fuse of the correct type (see NOTE below). Should a fuse blow for a second time then the complete unit should be returned to Radiodetection for investigation. The Blocking Filter should be tested annually for breakdown, please refer to the Service section of this manual for details. Blown Test Lead Fuses can be diagnosed as follows: Remove both crocodile clips from the cable under test prior to inspection of fuses. 6 2017 Radiodetection Ltd

Plug the Blocking Filter into the Lexxi T1660, with the range set to 33ft (10m) and ensure it is not connected to a cable. Short the crocodile clips together and check that the displayed pulse changes. If the pulse is unchanged, a fuse is blown. NOTE: The fuses fitted are 500mA Quick Action 1.3 (32mm) ceramic with a breaking capacity of at least 46kA at 600V ACrms 50/60Hz or 600V DC. 2017 Radiodetection Ltd 7

Specifications Parameter Specification Notes Ranges 7, 15, 30, 60, 120, 250, 500, 1000, 2000, 3000, 6000 Meters 23, 49, 98, 197, 394, 820, 1640, 3280, 6560, 9850, 19000 Feet Range Selection Manual range control Accuracy Display 1% of selected range* 320x640 pixel color backlit LCD Resolution Approx 1% of range Sensitivity Min 3 pixel return at 4km (13000 ) on 0.6mm (0.024 ) Ø cable Velocity Factor, VoP Adjustable from 1% to 99% Output Pulse Output Impedance Output Pulse Width Scan Rate Batteries Battery Life Voltage Protection Power Down Operating Temp Storage Temp Dimensions Weight 5V peak to peak Selectable 25, 50, 75 & 100 ohms 3ns to 3ms 2 scans/second Six AA (LR6/R6) Alkaline or NiMH cells 12 hours typical, continuous operation 600V AC Category III, 300V AC Category IV 250V AC Select 1, 3, 5, 10, 15 minutes or disabled -10ᵒ to 50ᵒC, 14ᵒ to 122ᵒF -20ᵒ to 70ᵒC, -4ᵒ to 158ᵒF 250x100x55mm, 9.8x4x2.2 600g, 1.3lb Safety IEC 61010-1, EMC BS/EN 61326-1 Water/Dust Proof IP54 PE Twisted Pair cable Into open circuit Automatic with range Alkaline batteries Lexxi T1660 with Mains Blocking Filter Lexxi T1660 with all other connections and Plug-In Module options (see Ordering information) * Measurement accuracy of ±1% assumes accurate setting of Velocity of Propagation (VoP), homogeneity of VoP along the length of the cable and accurate cursor positioning. 8 2017 Radiodetection Ltd

Ordering Information Description Sales Part Number Notes Lexxi T1660 TDR 10/T1660 Lexxi T1660 TDR 100Ω Twisted Pair, Alligator Clips 10/T1660-TP-ALLIG Connection cables Mains Blocking Filter, 25Ω, Cat IV 10/T1660-BLOCK-MOD Plug-in Module, option 50Ω Twisted Pair Plug-In, Croc Clip 10/T1660-TP-CROC-MOD-50 Plug-in Module, option 100Ω Twisted Pair Plug-In, Croc Clip 10/T1660-TP-CROC-MOD-100 Plug-in Module, option 75Ω BNC Plug-In, BNC-F adapter 10/T1660-BNC-MOD-75 Plug-in Module, option Lexxi T1660 Bag, clear cover 10/T1660-BAG Bag 2017 Radiodetection Ltd 9

Batteries The unit operates from six 1.5V AA (R6/LR6) batteries which can be either non-rechargeable alkalines or rechargeable NiMH. CAUTION: Do not attempt to recharge alkaline batteries WARNING: Disconnect the test leads from any cable before removing the battery cover To fit the batteries: Place the Lexxi T1660 face down Undo the battery compartment retainer (¼ turn anticlockwise) Lift off the cover and remove any old batteries, retaining the battery tubes if used Insert the batteries into the Lexxi T1660, using the battery tubes if available, ensuring the polarity markings match those in the battery compartment. Replace the cover and re-fasten the retainer (¼ turn clockwise). DO NOT OVERTIGHTEN NOTE: When you turn on your Lexxi T1660 after installing new batteries, it will ask you to choose the battery type. Scroll to the correct type using the Up and Down arrow keys, then press the Select key to choose that option. Service The Lexxi T1660 TDR contains no user serviceable items except the batteries. In the unlikely event of failure, please contact your local representative for details of repair or replacement. In order to maintain the accuracy of this equipment, it is recommended that annual calibration and maintenance is carried out. Please contact your local representative for details. The Blocking Filter should be tested annually for breakdown between the crocodile clips connected together on one side and the 4 mm banana plugs connected together on the other side. The test voltage 10 2017 Radiodetection Ltd

should be raised to 5550V ACrms 50/60Hz within 2s and maintained for 2s. This must only be carried out by trained personnel using the correct equipment. Contact Radiodetection to arrange for this retest. Care and maintenance Ensure the unit is switched off before any care and maintenance tasks are carried out. Cleaning The Lexxi T1660 may be cleaned with a soft cloth lightly dampened with soapy water. Remove all soap residue then dry instrument with a dry cloth. Compliance EU Compliance This equipment complies with the following EU Directives: IEC 61010-1, EMC BS/EN 61326-1 2017 Radiodetection Ltd 11

Warranty Subject to the conditions set out herein, Radiodetection Limited expressly and exclusively provides the following warranty to original end user buyers of Radiodetection products. Radiodetection hereby warrants that its products shall be free from defects in material and workmanship for two years starting from point of sale to end customer. Extensions of this warranty period may be available where the same terms and conditions apply. Statement of warranty conditions The sole and exclusive warranty for any Radiodetection product found to be defective is repair or replacement of the defective product at Radiodetection s sole discretion. Repaired parts or replacement products will be provided by Radiodetection on an exchange basis and will be either new or refurbished to be functionally equivalent to new. In the event this exclusive remedy is deemed to have failed of its essential purpose, Radiodetection s liability shall not exceed the purchase price of the Radiodetection product. In no event will Radiodetection be liable for any direct, indirect, special, incidental, consequential or punitive damages (including lost profit) whether based on warranty, contract, tort or any other legal theory. Warranty services will be provided only with the original invoice or sales receipt (indicating the date of purchase, model name and dealer s name) within the warranty period. This warranty covers only the hardware components of the Radiodetection product. Before a unit is submitted for service or repair, under the terms of this warranty or otherwise, any data stored on the unit should be backed-up to avoid any risk of data loss. Radiodetection will not be responsible for loss or erasure of data storage media or accessories. Radiodetection is not responsible for transportation costs and risks associated with transportation of the product. The existence of a defect shall be determined by Radiodetection in accordance with procedures established by Radiodetection. 12 2017 Radiodetection Ltd

This warranty is in lieu of any other warranty, express or implied, including any implied warranty of merchantability or fitness for a particular purpose. This warranty does not cover: a. Periodic maintenance and repair or parts replacement due to wear and tear. b. Consumables (components that are expected to require periodic replacement during the lifetime of a product such as non-rechargeable batteries, bulbs, etc.). c. Damage or defects caused by use, operation or treatment of the product inconsistent with its intended use. d. Damage or changes to the product as a result of: i. Misuse, including: - treatment resulting in physical, cosmetic or surface damage or changes to the product or damage to liquid crystal displays. ii. iii. iv. Failure to install or use the product for its normal purpose or in accordance with Radiodetection instructions on installation or use. Failure to maintain the product in accordance with Radiodetection instructions on proper maintenance. Installation or use of the product in a manner inconsistent with the technical or safety laws or standards in the country where it is installed or used. v. Virus infections or use of the product with software not provided with the product or incorrectly installed software. vi. The condition of or defects in systems with which the product is used or incorporated except other Radiodetection products designed to be used with the product. 2017 Radiodetection Ltd 13

vii. viii. ix. Use of the product with accessories, peripheral equipment and other products of a type, condition and standard other than prescribed by Radiodetection. Repair or attempted repair by persons who are not Radiodetection warranted and certified repair houses. Adjustments or adaptations without Radiodetection s prior written consent, including: a. upgrading the product beyond specifications or features described in the instruction manual, or modifications to the product to conform it to national or local technical or safety standards in countries other than those for which the product was specifically designed and manufactured. x. Neglect e.g. opening of cases where there are no userreplaceable parts. xi. Accidents, fire, liquids, chemicals, other substances, flooding, vibrations, excessive heat, improper ventilation, power surges, excess or incorrect supply or input voltage, radiation, electrostatic discharges including lightning, other external forces and impacts. 14 2017 Radiodetection Ltd

Global locations Radiodetection (USA) 28 Tower Road, Raymond, Maine 04071, USA Tel: +1 (207) 655 8525 Toll Free: +1 (877) 247 3797 rd.sales.us@spx.com www.radiodetection.com Pearpoint (USA) 39-740 Garand Lane, Unit B, Palm Desert, CA 92211, USA Tel: +1 800 688 8094 Tel: +1 760 343 7350 pearpoint.sales.us@spx.com www.radiodetection.com Radiodetection (Canada) 344 Edgeley Boulevard, Unit 34, Concord, Ontario L4K 4B7, Canada Tel: +1 (905) 660 9995 Toll Free: +1 (800) 665 7953 rd.sales.ca@spx.com www.radiodetection.com Radiodetection Ltd. (UK) Western Drive, Bristol, BS14 0AF, UK Tel: +44 (0) 117 976 7776 rd.sales.uk@spx.com www.radiodetection.com Radiodetection (France) 13 Grande Rue, 76220, Neuf Marché, France Tel: +33 (0) 2 32 89 93 60 rd.sales.fr@spx.com http://fr.radiodetection.com Radiodetection (Benelux) Industriestraat 11, 7041 GD s-heerenberg, Netherlands Tel: +31 (0) 314 66 47 00 rd.sales.nl@spx.com http://nl.radiodetection.com Radiodetection (Germany) Groendahlscher Weg 118, 46446 Emmerich am Rhein, Germany Tel: +49 (0) 28 51 92 37 20 rd.sales.de@spx.com http://de.radiodetection.com Radiodetection (Asia-Pacific) Room 708, CC Wu Building, 302-308 Hennessy Road, Wan Chai, Hong Kong SAR, China Tel: +852 2110 8160 rd.sales.asiapacific@spx.com www.radiodetection.com Radiodetection (China) Ming Hao Building D304, No. 13 Fuqian Avenue, Tianzhu Town, Shunyi District, Beijing 101312, China Tel: +86 (0) 10 8416-3372 rd.service.cn@spx.com http://cn.radiodetection.com Radiodetection (Australia) Unit H1, 101 Rookwood Road, Yagoona NSW 2199, Australia Tel: +61 (0) 2 9707 3222 rd.sales.au@spx.com www.radiodetection.com Radiodetection is a leading global develop and supplier of test equipment used by utility companies to help install, protect and maintain their infrastructure networks Copyright 2017 Radiodetection Ltd. All rights reserved. Radiodetection is a subsidiary of SPX Corporation. Radiodetection is a registered trademark of Radiodetection in the United States and/ or other countries. Due to a policy of continued development, we reserve the right to alter or amend any published specification without notice. This document may not be copied, reproduced, transmitted, modified or used, in whole or in part, without the prior written consent of Radiodetection Ltd.