Rheem Classic Plus Series Downflow Gas Furnace

Similar documents
W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. )

Rheem Classic Series Downflow Gas Furnace

W801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Ruud Ultra Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Series Upflow/Horizontal Gas Furnace

Rheem Classic Series Upflow/Horizontal Gas Furnace

Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace

Rheem Value Series Downflow Gas Furnace

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev.

W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. )

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1

UPFLOW/ HORIZONTAL GAS FURNACE

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models)

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

Rheem Classic Plus Super Quiet 80 Upflow/Horizontal Gas Furnace

Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace

GAS FURNACES CLASSIC SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES

Table of Contents GF801U Series

Rheem Classic Series Two-Stage Upflow/Horizontal Gas Furnaces

DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH

80% A.F.U.E. DOWNFLOW GAS FURNACES

GAS FURNACES CLASSIC SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES QUIET 80 80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

Rheem Value Series Upflow/Horizontal Gas Furnace

GAS FURNACES ACHIEVER SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

GAS FURNACES II 80.0% 81.4% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES SILHOUETTE

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

Sample Residence HVAC Load Calculations

Rheem High Efficiency Air Handler

Rheem Air Handlers. RHLP- Standard Efficiency X-13 (ECM) Motor

Cooling Capacity CFM in. w.c. (125 Pa)

A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN

95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES

FG7T (A and K Series)

G8MVL. Product Specifications

KG7T (E and N Series)

FG7T (E and N Series)

Ruud High Efficiency Air Handler

GUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

N9MSB. PS 92 Product Specifications. 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL /2/17

KG7T (C and L Series)

Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL

VMS8/VDS8. Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

FG7T (A and K Series)

KG7S (A and K Series)

Cooling Capacity CFM in. w.c. (125 Pa)

TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

Cooling Capacity CFM in. w.c. (125 Pa)

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

GMS9/GCS9 SERIES 93% AFUE

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

Cased/Uncased Coils For Gas And Oil Furnaces

DM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h

DD80HS. Two-Stage, Convertible Multi-Speed Gas Furnace 80% AFUE. Heating Input: 40, ,000 BTU/h

FG7S (C and L Series)

Cooling Capacity CFM in. w.c. (125 Pa)

F8MTL. Product Specifications

KG7T (C and L Series)

GMS8/GDS8/GHS8. Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

G9MXE. Product Specifications

TECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38, ,000 Btuh Input

TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

G9MXE. Product Specifications

95G1-E. Aluminized steel primary heat exchanger with crimped non-welded construction AL 29-4C Stainless steel secondary heat exchanger

AMS8 / ADSS8. Single-Stage Multi-Speed Gas Furnaces 80% AFUE. Heating Input: 40, ,000 BTU/h

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)

95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

Product Data. that this product meets the S 95% AFUE S Two -stage operation

96G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

95% Gas Furnaces. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 95G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)

TECHNICAL GUIDE 80 AFUE DOWNFLOW GAS-FIRED FURNACES MODELS: G8T-DN DESCRIPTION WARRANTY FEATURES Rev. B (0303)

A95-2V. 95% Gas Furnaces Two-Stage Variable Speed HEAT EXCHANGER DESIGN CONFIGURATIONS

Multi-Position, Multi-Speed Gas Furnaces

95% Gas Furnaces A95-1E. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits CONFIGURATIONS

Cased/Uncased Coils For Gas And Oil Furnaces

TECHNICAL GUIDE MODELS: P4HU 80 AFUE MULTI-POSITION GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger.

TSTAT0101SC Recommended (sold separately)

TECHNICAL GUIDE MODELS: P4DN 80 AFUE DOWNFLOW GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger.

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS)

GMH8/GDH8. Two-Stage Convertible Multi-Speed Gas Furnaces 80% AFUE

WFSR. Product Specifications 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER CABINET DESIGN AIR DELIVERY SYSTEM CONTROLS VENTING

TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES DESCRIPTION WARRANTY FEATURES Rev.

93% Gas Furnaces Single Stage

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN

Cased/Uncased Coils For Gas And Oil Furnaces

AMS8/ADSS8. Single-Stage. Heating Input: 40, ,000 BTU/h

80% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor

Transcription:

Gas Furnaces Rheem Classic Plus Series Downflow Gas Furnace R801T Downflow Series 80% A.F.U.E. Input Rates 75-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test procedures. 80% residential Gas Furnace CSA certified PlusOne Diagnostics 7 Segment LED all units PlusOne Ignition System DSI for reliability and longevity Heat exchanger is removable for improved serviceability. Aluminized steel construction provides maximum corrosion resistance and thermal fatigue reliability. Low profile 34" cabinet ideal for space constrained installations Integrated Control board features dip switches for easy system set up QR code for quick access to product information from your smart phone or tablet Insulated blower compartment Constant Torque electrically commutated motor FORM NO. G11-549 REV. 1

Table of Contents TABLE OF CONTENTS Standard & Optional Equipment...3 Model Features/Physical Data & Specifications...4 Model Number Identification...5 Dimensional Data...6 Blower Performance Data...7 Accessories...8 Limited Warranty...9 2

Standard & Optional Equipment CONSTANT TORQUE ECM MOTOR INTEGRATED FURNACE CONTROL DRAFT INDUCER MOTOR HEAT EXCHANGER DIRECT SPARK IGNITOR WITH REMOTE SENSE IN-SHOT BURNERS STANDARD EQUIPMENT Completely assembled and wired; induced draft; pressure switch; redundant main gas control; blower compartment door safety switch; solid state time on/time off blower control; limit control; manual shut-off valve, pressure regulator for natural and L.P. (propane) gas; transformer; direct drive multi-speed blower motor. Furnaces are equipped with cooling/heating relay and transformer (40VA) ready for air conditioning applications. (Please note: a thermostat is not included as standard equipment.) Flame sensor diagnostics; on-board twinning; fused-protection (secondary), 3rd speed option for continuous fan; common heat/cool terminal. OPTIONAL EQUIPMENT NOTE: Furnace is not listed for use with fuels other than natural or L.P. (propane) gas. The complete terms of limited and other warranties are available at our sales office, or through local installer. All models can be converted by a qualified Rheem distributor or local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a Rheem parts distributor. For L.P. (propane) operation, refer to Conversion Kit Index Form. NOTE: For natural and L.P. (propane) gas models, direct spark ignition is 100% lockout type. WARNING THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR USE IN MOBILE HOMES 3

Model Features/Physical Data & Specifications Model Features 80% residential Gas Furnace CSA certified PlusOne Diagnostics 7 Segment LED all units PlusOne Ignition System DSI for reliability and longevity Heat exchanger is removable for improved serviceability. Aluminized steel construction provides maximum corrosion resistance and thermal fatigue reliability. Low profile 34" cabinet ideal for space constrained installations Integrated Controls board features dip switches for easy system set up QR code for quick access to product information from your smart phone or tablet Insulated blower compartment Constant Torque electrically commutated motor Physical Data and Specifications U.S. and Canadian Models MODEL NUMBERS R801T (DF) SERIES Input in BTU s/hr [kw] ➁ Heating Capacity in BTU s/hr [kw] ➀ High Altitude Input in BTU s/hr [kw]* High Altitude Output Capacity in BTU s/hr [kw]* Heat Ext. Static Pressure in "wc [kpa] Blower (D x W) in inches [mm] Motor H.P.-Speeds - Type [W] R801TA075317Z*B 75,000 [22] 61,000 [18] 67,500 [20] 53,500 [16] 0.12 [0.029] 11 x 7 [279 x 178] 1/2hp, 5spd, X-13 [373] R801TA075521Z*B 75,000 [22] 62,000 [18] 67,500 [20] 53,500 [16] 0.12 [0.029] 11 x 10 [279 x 254] 1hp, 5spd, X-13 [746] Max. Overload Protection Device 15 20 Heating Speed (factory setting) MED-HIGH MED Cooling Speed (factory setting) HIGH HIGH Cooling in CFM [L/s] @ 0.5"wc [0.12 kpa] E.S.P. (nominal) Rated E.S.P. in "wc [kpa] Temperature Rise Range in F [ C] Max Outlet Air in F [ C] Approx. Shipping Weight in Lbs. [kg] 1200 [566] 0.5 [0.12] 30-60 [17-33] 165 [73.8] 105 [48] 2000 [944] 0.5 [0.12] 25-55 [13.9-30.6] 165 [73.8] 120 [54] AFUE - Electronic Ignition Modules ➀ 80.0% 80.0% R801TA100521Z*B 100,000 [29] 82,000 [24] 90,000 [26] 72,500 [21] 0.15 [0.037] 11 x 10 [279 x 254] 1hp, 5spd, X-13 [746] R801TA125524Z*B 125,000 [37] 103,000 [30] 112,500 [33] 89,000 [26.1] 0.2 [0.05] 11 x 10 [279 x 254] 1hp, 5spd, X-13 [746] Min. Circuit Ampacity 9 13 12 15 Min. Overload Protection Device 15 15 15 20 NOTES: All models are 115V, 60HZ, 1Ø. Gas connection size for all models is 1 /2" N.P.T. ➀ In accordance with D.O.E. test procedures. ➁ See Conversion Kit Index Form for high altitude derate in U.S. applications. 15 25 MED-HIGH MED-HIGH HIGH HIGH 2000 [944] 0.5 [0.12] 30-60 [17-33] 190 [87.7] 120 [54] 2000 [944] 0.5 [0.12] 35-65 [19.4-36.1] 185 [85.0] 140 [63] 80.0% 80.0% [ ] Designates Metric Conversions 4

Model Number Identification Model Number Identification Downflow Models R 80 1 T A 075 4 17 Z S A Rheem 80 = 80% AFUE 1 = Single Stage T = Constant Torque Design Series A = 1st Design Input BTU/HR [kw] 075 = 75,000 [22] 100 = 100,000 [29] 125 = 125,000 [37] 3 = Up to 3 Ton 4 = 2 1 /2 to 4 Ton 5 = 3 1 /2 to 5 Ton Cabinet Width 17 = 17.5" 21 = 21".0 24 = 24.5" Z = Down and Zero Clearance Downflow X = Low NOx S = Standard Revision- Marketing A First Time Release B 2nd Design Series [ ] Designates Metric Conversions 5

Dimensional Data Downflow Dimensions Dimensional Data MODEL R801T (DOWNFLOW) SERIES A B C D E LEFT SIDE RIGHT SIDE REDUCED CLEARANCES (IN.) [mm] BACK TOP FRONT VENT SHIP. WGTS. (LBS.) [kg] 075317 17 1 /2 [445] 16 11 /32 [415] 12 1 /8 [308] ➀ 16 5 /8 [422] 0 3 ➁ 0 1 [25] 3 [76] 6 [152] ➂ 105 [47.6] 075521 21 [533] 19 27 /32 [504] 13 7 /8 [352] ➀ 20 1 /8 [511] 0 0 0 1 [25] 3 [76] 6 [152] ➂ 120 [54.4] 100 21 [533] 19 27 /32 [504] 13 7 /8 [352] ➀ 20 1 /8 [511] 0 0 0 1 [25] 3 [76] 6 [152] ➂ 120 [54.4] 125 24 1 /2 [622] 23 11 /32 [593] 15 5 /8 [397] ➀ 23 5 /8 [600] 0 0 0 1 [25] 3 [76] 6 [152] ➂ 140 [63.5] NOTES: ➀ May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter. ➁ May be 0" [0 mm] with type B vent. ➂ May be 1" [25 mm] with type B vent. Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and in accordance with local codes. [ ] Designates Metric Conversions 6

Blower Performance Data Blower Performance Data Downflow Models AIR FLOW PERFORMANCE - (-)801T SERIES (Downflow) MODELS MODEL (-)801TA075317ZSA (-)801TA075521ZSA (-)801TA100521ZSA (-)801TA125524ZSA NOTE: Bold data is factory heating tap MOTOR H.P. [W] BLOWER SIZE IN [mm] 1/2 [373] 11 x 7 [279 x 178] 1 [748] 11 x 10 [279 x 254] 1 [748] 11 x 10 [279 x 254] 1 [748] 11 x 10 [279 x 254] SPEED TAP Low Med. Lo Med Med. Hi High Low Med. Lo Med Med. Hi High Low Med. Lo Med Med. Hi High Low Med. Lo Med Med. Hi High CFM [L/s] AIR DELIVERY EXTERNAL STATIC PRESSURE INCHES WATER COLUMN [kpa] 0.1 [.02] 0.2 [.05] 0.3 [.07] 0.5 [.12] 0.6 [.15] 0.8 [.19] 916 993 1205 1367 1475 1198 1411 1608 1918 2122 1240 1405 1600 1903 2072 1225 1302 1553 1902 2403 803 952 1158 1333 1444 1105 1358 1564 1877 2083 1120 1364 1561 1877 2028 1073 1240 1503 1859 2369 669 910 1124 1300 1416 1093 1317 1529 1840 2054 1073 1317 1526 1833 2006 988 1191 1455 1822 2332 561 827 1056 1236 1354 931 1227 1451 1767 1977 974 1232 1445 1766 1940 864 1074 1370 1722 2246 504 793 1024 1203 1329 901 1196 1416 1706 1945 917 1181 1403 1711 1908 795 1027 1313 1686 2190 421 706 950 1140 1264 791 1093 1340 1636 1874 799 1083 1325 1631 1840 697 932 1237 1602 2059 [ ] Designates Metric Conversions 7

Accessories DOWNFLOW ACCESSORIES DOWNFLOW WARNING: Unit design is certified for installation on noncombustible floor. A special factory supplied combustible floor subbase is required when installing on a combustible floor. Failure to install the sub-base may result in fire, property damage and personal injury. COMBUSTIBLE FLOOR BASE DIMENSIONS COMBUSTIBLE FLOOR BASE USE WITH FURNACE SIZES A IN. [mm] B IN. [mm] C IN. [mm] RXGC-B17 R801T075317 18 [457] 16 3 /4 [425] 14 3 /4 [451] RXGC-B21 R801T100521, R801T075521 21 1 /2 [546] 20 1 /4 [514] 18 1 /4 [464] RXGC-B24 R801T125 25 [635] 23 3 /4 [603] 21 3 /4 [552] [ ] Designates Metric Conversions RXGF-CC* FILTER RACK Downflow top return mount. Requires (2) 14 x 20 Filters. NOTE: Filter racks are shipped without filters. *Filters available through PROSTOCK. FOR HIGH ALTITUDES: HIGH ALTITUDE OPTION CODE: U.S. & Canada None required for high altitudes. HIGH ALTITUDE CONVERSION KITS: U.S. & Canada None required for high altitudes. 80+ HIGH ALTITUDE INSTRUCTIONS Caution: Always follow National Fuel Gas Code (NFGC) guidelines when converting for high altitudes. High altitude option codes are not required for these models. However, the burner orifice size needs to be recalculated and verified at elevations above 2000 ft. See Installation Instructions for more information. NOTE: For Canadian installations only, an optional derate (manifold gas pressure reduction) method may be used to adjust the furnace for altitude. See Installation Instructions for more information. This optional method may NOT be used for U.S. installations. 8

Limited Warranty GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. *For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate. Heat Exchanger...Twenty (20 Years Conditional Parts (Registration Required)...Ten (10) Years 9

Notes 10

Notes 11

The new degree of comfort. In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Heating, Cooling & Water Heating P.O. Box 17010 Fort Smith, Arkansas 72917 www.rheem.com Rheem Canada Ltd./Ltée 125 Edgeware Road, Unit 1 Brampton, Ontario L6Y 0P5 PRINTED IN U.S.A. 2/17 QG FORM NO. G11-549 REV. 1