LOW & MEDIUM PRESSURE FILTERS

Similar documents
STAINLESS STEEL HIGH PRESSURE FILTERS

LMP series. 305 Low & Medium Pressure filters MULTIPORT. Maximum pressure up to 80 bar - Flow rate up to 200 l/min

Hydraulic Filtration Products PANTONE.pdf 1 09/08/17 18:34 SPIN-ON FILTERS C M Y CM MY CY CMY K

FHF325 series. Filter housing according to SAE J2066 for HF4 filter elements. High Pressure fi lters

Hydraulic Filtration. Product Range. Low & Medium Pressure Filters. Return Filters MPFX MPTX MFBX. China United Kingdom India Canada

Return / Suction fi lters In-line. LMP 124 series MULTIPORT. Maximum pressure up to 80 bar - Flow rate up to 200 l/min. Return / Suction fi lters

DIN Filter element according to DIN Low & Medium Pressure filters. Maximum pressure up to 60 bar - Flow rate up to 330 l/min

LDP & LDD series Filter element according to DIN Maximum working pressure up to 6 MPa (60 bar) - Flow rate up to 330 l/min

LMP series

HYDRAULIC FILTRATION PRODUCTS

525 Stainless steel high pressure filters. FZP series. Maximum pressure up to 420 bar. Stainless steel high pressure fi lters

RETURN / SUCTION FILTERS

High Pressure fi lters. FHP series. Maximum pressure up to 420 bar - Flow rate up to 750 l/min. High Pressure fi lters

Return / Suction fi lters Tank mounted. MRSX series. Maximum pressure up to 10 bar - Flow rate up to 300 l/min. Return / Suction fi lters

NEW. High Pressure filters. FMM 150 series. Maximum pressure up to 420 bar - Flow rate up to 250 l/min

A complete line of pressure differential visual and electrical indicators are available with this series of filters.

Series RFLD Duplex In-Line Filter

[You may download this article at: ]

Filter elements for installation in Pall filter housings. Type 16. filter elements. Contents. Features. RE Edition:

ES 074 ES 094 Tank top mounting Connection up G1¼ Nominal flow rate up to 80 l/min

LS 025 LS 035 In-line mounting Connection up to G¾ / -12 SAE Nominal flow rate up to 33 l/min / 8.7 gpm

Spin-on elements. Type 80, 81 and 82. Contents. Features. RE Edition:

ES 134 ES 144 Tank top mounting Connection up to SAE 1½ Nominal flow rate up to 130 l/min

SPIN-ON FILTER - LOW PRESSURE LINE

Filter elements, two-stage for installation in wind turbines with Hydac filter housings. Type 65. Filter elements. Contents.

Filter elements for microfiltration. Type 46. CELLUDISC filter elements. Features. Contents. RE Edition:

HD 790 HD 990 In-line mounting Operating pressure up to 630 bar Nominal flow rate up to l/min

RETURN FILTERS. MATERIALS Head: Aluminium alloy Spin-on cartridge: Steel Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass

HD 790 HD 990 In-line mounting Operating pressure up to 630 bar / 9137 psi Nominal flow rate up to l/min / gpm

Filtering elements differential collapsing pressure tested in compliance with ISO 2941:

FMP IN-LINE FILTER SERIES. Maximum working pressure 250 bar. Flow rate to 500 l/min

RETURN FILTERS. MATERIALS Head: Aluminium alloy Cover & bowl: Polyammide Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

Series RFL In-Line Filter

ES 094 Tank top mounting Connection up to G1¼ Nominal flow rate up to 70 l/min

MPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN. Maximum working pressure 12 bar. Flow rates to 300 l/min

D e s c r i p t i o n

FNA 045 Operating pressure up to 7 bar / 101 psi Nominal flow rate up to 45 l/min / 12 gpm

We produce fluid power solutions. Fluid Management. Off-line Filters Off-line Filter Units Oil Service Units Dewatering Systems Filter Elements

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane

D 162 D 232 D 332 In-line mounting Operating pressure up to 63 bar Nominal flow rate up to 350 l/min

Return-Suction Filters E 068 E 088. In-line mounting Connection up to G¾ Nominal flow rate up to 100 l/min e

PRESSURE FILTERS. BYPASS VALVE Setting: 170 kpa (1,7 bar) ± 10% WORKING TEMPERATURE From -25 to +110 C

Return fi lters. FRI series. Maximum pressure up to 20 bar - Flow rate up to 1500 l/min. Return fi lters

E 068 E 088 In-line mounting Connection up to G¾ Nominal flow rate up to 100 l/min

FN 060 FN 300 In-line mounting Operating pressure up to 12 bar / 174 psi Nominal flow rate up to 650 l/min / 172 gpm

Connection Ports: 3/4 1 1/4 BSP (other thread options on request)

10 Hydraulic Filters

High Pressure Filters HD 044 HD 064. Flangeable Operating pressure up to 500 bar Nominal flow rate up to 105 l/min e

In line high pressure filters. HF 725 series

High Pressure Filters Worldline 400 HD 790 HD 990. In-line mounting Operating pressure up to 9137 psi Nominal flow rate up to gpm. 40.

Off-line Filters FNS 060. With flow control valve Operating pressure up to 320 bar Nominal flow rate up to 4 l/min e

In line high pressure filters. HF 735 series

Return-Suction Filters E 158 E 198 E 248. Tank top mounting Connection up to -20 SAE Nominal flow rate up to 66 gpm us

FNA 008 FNA 016 Operating pressure up to 4 bar / 58 psi Nominal flow rate up to 16 l/min / 4.2 gpm

MATERIALS CARTRIDGES PRESSURES VALUES TESTS CARRIED OUT ON FILTER ELEMENTS

10 Hydraulic Filters

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)

Connection Ports: 1/2 1 1/2 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

MPF filters within this range are suitable for flow rates up to 750 l/min.

Ultipleat SRT Filters

Components and Systems for the Automotive Industry

HIGH PRESSURE FILTERS

Line filter with filter element according to DIN 24550

A complete line of pressure differential visual and electrical indicators are available with this series of filters.

Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T ) Burst 840 bar (12200 psi) (acc. to NFPA T )

HIGH PRESSURE FILTERS

Off-line Oil Filter Module Pi 8400

THE IMPORTANCE OF AN EFFICIENT FILTRATION

Spin-on filter according to Bosch Rexroth standard: Type 50 SL 30 to 80D. Features. Contents. RE Edition:

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T )

FNK 050 FNK 100 Operating pressure up to 10 bar Nominal flow rate up to 125 l/min Cooling capacity up to 45 kw

SRX R. Remediation Pumps. Simply Reliable

HIGH PRESSURE FILTERS

Automatic Back-Flushing Filter AutoFilt RF9.

Inline Filter RFL. Cast version Volume rates up to 1300 l/min* Pressure range 25/40 bar

Portable Filter Carts. Models 5MFP & 10MFP with Modufl ow and Intelli-Cart

Hydraulics. Axial Piston Pumps Series PVP. Introduction. With thru shaft option for multiple pump options Swash plate type for open circuit

Flow rates to 500 l/min

Introduction to Hydraulic Filtration

Block mounting filter, for vertical flange-mounting

Pressure: Max working F280 D12x port size 1/2 & 3/4 : 420 bar (6000 psi) Burst F280 D12x port size 1/2 & 3/4 : 1260 bar (18000 psi)

FPG-MDS PRESSURE FILTERS MATERIALS PRESSURE BYPASS VALVE WORKING TEMPERATURE COMPATIBILITY (ISO 2943) HYDRAULIC DIAGRAM.

22PD/32PD Series High Pressure Duplex Filters Max 260 l/min bar

HIGH PRESSURE FILTERS Series HF2P

Number Title Year Organization Page

Fluid Cooling Industrial COLW Series

Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T ) Burst 330 bar (4800 psi) (acc. to NFPA T ) Wire mesh µm

Spin-on filter according to Bosch Rexroth standard. Type 7 SL ; 7 SLS Features. Contents. RE Edition: Replaces: 01.

Block mounting filter, for lateral flange-mounting

Inline filter with filter element according to DIN 24550

FILTER ELEMENTS. Overview of Elements PN# / / FIL

Filter elements for the installation into Hydac filter housings. Type 9. and 10. filter elements. Features. Contents

FILTER MEDIA. Mainly used filter material: INTERPOR FLEECE VG GLASS FIBRE PAPER MATTING P STAINLESS STEEL MESH G

Inline filter with filter element according to DIN 24550

Block mounting filter, for lateral flange-mounting

HYDAC LowViscosity Housings: Highest diesel quality on the whole transport route

Inline Filter MFM. Flow rates up to 100 l/min Pressure range up to 280 bar Material: EN-GJS / steel E /01.04

Connection Ports: 3/4 1 1/4 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Inline Filter RFLD. Change-Over. Cast Version Flow Rates up to 1300 l/min* Pressure Range 25/40/64 bar With Ball Change-Over Valve E /01.

Transcription:

LOW & MEDIUM PRESSURE FILTERS

A WORLDWIDE LEADER IN THE FIELD OF HYDRAULIC FILTRATION EQUIPMENT. Our company started life in 96, when Bruno Pasotto decided to attempt to cater for the requests of a market still to be fully explored, with the study, design, development, production and marketing of a vast range of fi lters for hydraulic equipment, capable of satisfying the needs of manufacturers in all sectors. The quality of our products, our extreme competitiveness compared with major international producers and our constant activities of research, design and development has made us a worldwide leader in the fi eld of hydraulic circuit fi ltering. Present for 50 years in the market, we have played a truly decisive role in defi ning our sector, and by now we are a group capable of controlling our entire chain of production, monitoring all manufacturing processes to guarantee superior quality standards and to provide concrete solutions for the rapidly evolving needs of customers and the market.

MARKET LEADER Our work is based on a skillful interaction between advanced technology and fine workmanship, customizing products according to specific market requests, focusing strongly on innovation and quality, and following every step in the manufacturing of both standard and special products, fully respecting customer expectations. Our customer-oriented philosophy, which enables us to satisfy all customer requests rapidly and with personalized products, makes us a dynamic and flexible enterprise. The possibility of constantly controlling and monitoring the entire production process is essential to allow us to guarantee the quality of our products. Introduction

WORLDWIDE PRESENCE Our foreign Branches enable us to offer a diversified range of products that allow us to successfully face the aggressive challenge of international competition, and also to maintain a stable presence at a local level. The Group boasts 8 business branches USA CANADA UNITED KINGDOM FRANCE GERMANY ITALY RUSSIA P.R. CHINA INDIA Introduction

TECHNOLOGY Our constant quest for excellence in quality and technological innovation allows us to offer only the best solutions and services for applications in many fields, including general industry, test rigs, lubrication, heavy engineering, renewable energies, naval engineering, offshore engineering, aviation systems, emerging technologies and mobile plant (i.e. tractors, excavators, concrete pumps, platforms). Introduction

AND PRODUCTION Our high level of technological expertise means we can rely entirely on our own resources, without resorting to external providers. This in turn enables us to satisfy a growing number of customer requests, also exploiting our constantly updated range of machines and equipment, featuring fully-automated workstations capable of -hour production. 5 Introduction

SUCTION FILTERS RETURN FILTERS RETURN / SUCTION FILTERS SPIN-ON FILTERS LOW & MEDIUM PRESSURE FILTERS HIGH PRESSURE FILTERS Flow rates up to 875 l/min Flow rates up to 000 l/min Flow rates up to 00 l/min Flow rates up to 65 l/min Flow rates up to 000 l/min Flow rates up to 750 l/min Mounting: - Tank immersed - In-Line - In tank with shut off valve - In tank with fl ooded suction Pressure up to 0 bar Mounting: - In-Line - Tank top - In single and duplex designs Pressure up to 80 bar Mounting: - In-Line - Tank top Pressure up to 5 bar Mounting: - In-Line - Tank top Pressure up to 80 bar Mounting: - In-Line - Parallel manifold version - In single and duplex designs Pressure from 0 bar up to 560 bar Mounting: - In-Line - Manifold - In single and duplex designs Introduction 6

PRODUCT RANGE MP Filtri can offer a vast and articulated range of products for the global market, suitable for all industrial sectors using hydraulic equipment. This includes filters (suction, in-line, pressure, stainless steel, spin-on and return) and structural components (motor/pump bell housings, transmission couplings, flexible inserts, damper rings, support feet, aluminium tanks, inspection hatches). We can provide all the skills and solutions required by the modern hydraulics industry to monitor contamination levels and other fl uid conditions. Mobile fi ltration units and a full range of accessories allow us to supply everything necessary for complete hydraulic circuits. STAINLESS STEEL HIGH PRESSURE FILTERS CONTAMINATION MONITORING PRODUCTS MOBILE FILTRATION UNITS POWER TRANSMISSION PRODUCTS ACCESSORIES Flow rates up to 5 l/min Pressure from 0 bar up to 000 bar Mounting: - In-Line - Manifold - In single and duplex designs - Calibrated on test rigs manufactured and certifi ed to ISO 9 based on methods from ISO 7 - Off-line and In-line particles counting up to 00 bar - Bottle samplers - RS - RS 85 digital bus interfaces Flow rates from 5 l/min up to 00 l/min - Aluminium bell-housings for motors from 0. kw to 00 kw - Couplings in Aluminium Cast Iron - Steel - Damping rings - Foot bracket - Aluminium tanks - Cleaning covers - Oil fi ller and air breather plugs - Optical and electrical level gauges - Pressure gauge valve selectors - Pipe fi xing brackets - Pressure gauges 7 Introduction

HYDRAULIC FILTRATION PRODUCTS page 6 0 0 INTRODUCTION COMPANY PRODUCT RANGE CONTAMINATION MANAGEMENT FILTER SIZING CORRECTIVE FACTOR page 7 5 5 STR - MPA - MPM SF 50-50 SF 500 CLOGGING INDICATORS SUCTION FILTERS Submerged suction filter, with bypass or magnetic column Semi-submerged positive head suction filter Semi-submerged positive head suction filter up to Q max l/min gpm 875 60 800 56 page 59 87 05 9 57 6 9 07 MPFX MPTX MFBX MPF MPT MFB MPH - MPI FRI RF CLOGGING INDICATORS ACCESSORIES RETURN FILTERS Tank top semi-immersed filter, standard filter element disassembly Tank top semi-immersed filter, easy filter element disassembly Bowl assembly fully immersed filter Tank top semi-immersed filter, standard filter element disassembly Tank top semi-immersed filter, easy filter element disassembly Bowl assembly fully immersed filter Tank top semi-immersed filter with internal / external oil flow Tank top semi-immersed filter, easy filter element disassembly, it can be used also as in-line filter Semi-immersed under-head filter, easy filter element disassembly up to P max bar psi 8 6 8 6 8 6 8 6 0 5 0 90 0 90 up to Q max l/min gpm 750 98 00 80 500 750 98 00 80 500 000 79 500 97 50 9 6 page 9 9 5 MRSX LMP MULTIPORT CLOGGING INDICATORS RETURN / SUCTION FILTERS Unique TANK TOP filter for mobile machinery, with combined filtration on return and suction to the inlet at the hydrostatic transmissions in closed circuit. Unique IN-LINE filter for mobile machinery, with combined filtration on return and suction to the inlet at the hydrostatic transmissions in closed circuit. up to P max bar psi 0 5 80 60 up to Q max l/min gpm 00 80 00 5 58 page 6 77 85 9 MPS MSH MST CLOGGING INDICATORS SPIN-ON FILTERS Low pressure filter, available with single cartdridge for in-line or flange mounting or with two cartdridge on the same axis on the opposite sides In-line low and medium pressure filter available with single cartdridge Low pressure tank mounted filter up to P max bar psi 00 5 508 00 up to Q max l/min gpm 65 96 95 5 95 5 Introduction 8

INDEX 0 page 05 5 59 67 79 87 0 09 8 LMP MULTIPORT 0-0 - LMP 0 - LMP 00-0 - 0 - LMP 900-90 LMP 90-90 LMP 950-95 LMP 95-95 - 95 LMD LMD 00-0 - LMD 95 LDP - LDD CLOGGING INDICATORS LOW & MEDIUM PRESSURE FILTERS In-line filter with Multiport design for multiple choice connection In-line low & medium pressure filter In-line low & medium pressure filter In-line low pressure filter, filter elements designed according to DIN 550 In-line filter specifically designed to be mounted in series, filter elements designed according to DIN 550 In-line modular filter, available with and up to 6 different heads In-line low pressure filter specifically designed to be mounted in series In-line duplex medium pressure filter In-line duplex low pressure filter In-line duplex modular filter, available with up to 6 different heads In-line and duplex medium pressure filter, filter elements designed according to DIN 550 up to P max bar psi 80 60 60 870 60 870 0 5 0 90 0-5 5-6 5 6 60 870 6 6-5 -6 60 870 up to Q max l/min gpm 00 5 0 87 70 95 000 58 000 79 00 6 000 79 0 88 590 56 00 5 0 88 page 7 5 5 59 67 8 95 505 56 FMP 09 FMP FHP FMM 050 FHA 05 FHM FHB FHF 5 FHD CLOGGING INDICATORS HIGH PRESSURE FILTERS Versatile filter for high pressure - low flow rate applications Versatile filter for high pressure - high flow rate applications Typical high pressure filter for mobile applications FMM 050: Typical high pressure filter for mobile applications FHA 05: Filter optimized for use in high pressure operating systems High pressure filter with intermediate plate construction High pressure for block mounting In-line manifold top mounting In-line duplex high pressure filter up to P max bar psi 0 595 0 6 0 609 0 609 560 8 0 6 0 6 50 5076 50 5076 up to Q max l/min gpm 80 75 5 750 98 50 0 0 7 50 9 85 8 500 5 9 5 page 55 55 5 55 559 567 577 FZP FZH FZX FZB FZM FZD CLOGGING INDICATORS STAINLESS STEEL HIGH PRESSURE FILTERS In-line pressure filter with threaded mount In-line pressure filter with threaded mount for higher pressure In-line pressure filter with threaded mount up to 000 bar Manifold side mounting Manifold top mounting Duplex pressure filter for continuous operation requirements up to P max bar psi 0 609 700 05 000 50 0 6 0 6 50 5076 up to Q max l/min gpm 50 0 50 0.6 75 0 70 8 90 580 page 585 QUICK REFERENCE GUIDE CLOGGING INDICATORS 9 Introduction

Introduction 0

Introduction Contamination management INDEX 5 6 7 8 HYDRAULIC FLUIDS FLUIDS CONTAMINATION EFFECTS OF CONTAMINATION ON HYDRAULIC COMPONENTS MEASURING THE SOLID CONTAMINATION LEVEL FILTRATION TECHNOLOGIES RECOMMENDED CONTAMINATION CLASSES & FILTER TYPES FILTER SIZING PARAMETERS APPLICABLE STANDARDS FOR FILTER DEVELOPMENT Page 6 7 8 8 Introduction

CONTAMINATION MANAGEMENT HYDRAULIC FLUIDS The fl uid is the vector that transmits power, energy within an oleodynamic circuit. In addition to transmitting energy through the circuit, it also performs additional functions such as lubrication, protection and cooling of the surfaces. The classifi cation of fl uids used in hydraulic systems is coded in many regulatory references, different Standards. The most popular classifi cation criterion divides them into the following families: - MINERAL OILS Commonly used oil deriving fl uids. - FIRE RESISTANT FLUIDS Fluids with intrinsic characteristics of incombustibility or high fl ash point. - SYNTHETIC FLUIDS Modifi ed chemical products to obtain specifi c optimized features. - ECOLOGICAL FLUIDS Synthetic or vegetable origin fl uids with high biodegradability characteristics. The choice of fl uid for an hydraulic system must take into account several parameters. These parameters can adversely affect the performance of an hydraulic system, causing delay in the controls, pump cavitation, excessive absorption, excessive temperature rise, effi ciency reduction, increased drainage, wear, jam/block or air intake in the plant. The main properties that characterize hydraulic fl uids and affect their choice are: - DYNAMIC VISCOSITY It identifi es the fl uid s resistance to sliding due to the impact of the particles forming it. - CINEMATIC VISCOSITY It is a widespread formal dimension in the hydraulic fi eld. It is calculated with the ratio between the dynamic viscosity and the fluid density. Cinematic viscosity varies with temperature and pressure variations. - VISCOSITY INDEX This value expresses the ability of a fluid to maintain viscosity when the temperature changes. A high viscosity index indicates the fluid s ability to limit viscosity variations by varying the temperature. - FILTERABILITY INDEX It is the value that indicates the ability of a fluid to cross the filter materials. A low fi lterability index could cause premature clogging of the fi lter material. - WORKING TEMPERATURE Working temperature affects the fundamental characteristics of the fluid. As already seen, some fl uid characteristics, such as cinematic viscosity, vary with the temperature variation. When choosing a hydraulic oil, must therefore be taken into account of the environmental conditions in which the machine will operate. - COMPRESSIBILITY MODULE Every fl uid subjected to a pressure contracts, increasing its density. The compressibility module identifies the increase in pressure required to cause a corresponding increase in density. - HYDROLYTIC STABILITY It is the characteristic that prevents galvanic pairs that can cause wear in the plant/system. - ANTIOXIDANT STABILITY AND WEAR PROTECTION These features translate into the capacity of a hydraulic oil to avoid corrosion of metal elements inside the system. - HEAT TRANSFER CAPACITY It is the characteristic that indicates the capacity of hydraulic oil to exchange heat with the surfaces and then cool them. FLUID CONTAMINATION Whatever the nature and properties of fluids, they are inevitably subject to contamination. Fluid contamination can have two origins: - INITIAL CONTAMINATION Caused by the introduction of contaminated fl uid into the circuit, or by incorrect storage, transport or transfer operations. - PROGRESSIVE CONTAMINATION Caused by factors related to the operation of the system, such as metal surface wear, sealing wear, oxidation or degradation of the fluid, the introduction of contaminants during maintenance, corrosion due to chemical or electrochemical action between fluid and components, cavitation. The contamination of hydraulic systems can be of different nature: - SOLID CONTAMINATION For example rust, slag, metal particles, fi bers, rubber particles, paint particles - or additives - LIQUID CONTAMINATION For example, the presence of water due to condensation or external infi ltration or acids - GASEOUS CONTAMINATION For example, the presence of air due to inadequate oil level in the tank, drainage in suction ducts, incorrect sizing of tubes or tanks. EFFECTS OF CONTAMINATION ON HYDRAULIC COMPONENTS Solid contamination is recognized as the main cause of malfunction, failure and early degradation in hydraulic systems. It is impossible to delete it completely, but it can be effectively controlled by appropriate devices. CONTAMINATION IN PRESENCE OF LARGE TOLERANCES CONTAMINATION IN PRESENCE OF NARROW TOLERANCES Solid contamination mainly causes surface damage and component wear. - ABRASION OF SURFACES Cause of leakage through mechanical seals, reduction of system performance, failures. Introduction

CONTAMINATION MANAGEMENT - SURFACE EROSION Cause of leakage through mechanical seals, reduction of system performance, variation in adjustment of control components, failures. - ADHESION OF MOVING PARTS Cause of failure due to lack of lubrication. - DAMAGES DUE TO FATIGUE Cause of breakdowns and components breakdown.stem performance, failures. - SURFACE EROSION Cause of leakage through mechanical seals, reduction of system performance, variation in adjustment of control components, failures. - ADHESION OF MOVING PARTS Cause of failure due to lack of lubrication. - DAMAGES DUE TO FATIGUE Cause of breakdowns and components breakdown. Gaseous contamination mainly results in decay of system performance. - CUSHION SUSPENSION Cause of increased noise and cavitation. - FLUID OXIDATION Cause of corrosion acceleration of metal parts. - MODIFICATION OF FLUID PROPERTIES (COMPRESSIBILITY MODULE, DENSITY, VISCOSITY) Cause of system s reduction of efficiency and of controllability. It is easy to understand how a system without proper contamination management is subject to higher costs than a system that is provided. - MAINTENANCE Maintenance activities, spare parts, machine stop costs - ENERGY AND EFFICIENCY Efficiency and perfomance reduction due to friction, drainage, cavitation. ABRASION EROSION MEASURING THE SOLID CONTAMINATION LEVEL ADHESION FATIGUE The level of contamination of a system identifi es the amount of contaminant contained in a fl uid. This parameter refers to a unit volume of fl uid. The level of contamination may be different at different points in the system. From the information in the previous paragraphs it is also apparent that the level of contamination is heavily infl uenced by the working conditions of the system, by its working years and by the environmental conditions. What is the size of the contaminating particles that we must handle in our hydraulic circuit? Liquid contamination mainly results in decay of lubrication performance and protection of fl uid surfaces. HUMAN HAIR (75 µm) DISSOLVED WATER - INCREASING FLUID ACIDITY Cause of surface corrosion and premature fl uid oxidation - GALVANIC COUPLE AT HIGH TEMPERATURES Cause of corrosion MINIMUM DIMENSION VISIBLE HUMAN EYES (0 µm) FREE WATER - ADDITIONAL EFFECTS - DECAY OF LUBRICANT PERFORMANCE Cause of rust and sludge formation, metal corrosion and increased solid contamination - BATTERY COLONY CREATION Cause of worsening in the fi lterability feature - ICE CREATION AT LOW TEMPERATURES Cause damage to the surface - ADDITIVE DEPLETION Free water retains polar additives TYPICAL CONTAMINANT DIMENSION IN A HYDRAULIC CIRCUIT ( µm) Contamination level analysis is signifi cant only if performed with a uniform and repeatable method, conducted with standard test methods and suitably calibrated equipment. To this end, ISO has issued a set of standards that allowa to conduct tests and express the measured values in the following ways. Introduction

CONTAMINATION MANAGEMENT - GRAVIMETRIC LEVEL - ISO 05 The level of contamination is defined by checking the weight of particles collected by a laboratory membrane. The membrane must be cleaned, dried and desiccated, with fluid and conditions defined by the Standard. The volume of fluid is filtered through the membrane by using a suitable suction system. The weight of the contaminant is determined by checking the weight of the membrane before and after the fluid filtration. ISO 06:999 Cleanliness Code System Microscope counting examines the particles differently to APCs and the code is given with two scale numbers only. These are at 5 µm and 5 µm equivalent to the 6 µm (c) and µm (c) of APCs. 0 7 0 6.6 8 Cleanliness Code Chart with 00 ml sample volume /9/ Example Code /9/ - CUMULATIVE DISTRIBUTION OF THE PARTICLES SIZE - ISO 06 5 0 The level of contamination is defined by counting the number of particles of certain dimensions per unit of volume of fluid. Measurement is performed by Automatic Particle Counters (APC). Following the count, the contamination classes are determined, corresponding to the number of particles detected in the unit of fluid. The most common classification methods follow ISO 06 and SAE AS 059 (Aerospace Sector) regulations. NAS 68 is still used although obsolete. 0 5.5. 6.. 9 8 7 6 5 Classification example according to ISO 06 The code refers to the number of particles of the same size or greater than, 6 or µm in a ml fluid. 0.6 8 Class 8 7 6 5 0 9 8 7 6 5 0 9 8 7 6 5 0 > µm (c) = 50 particles > 6 µm (c) = 00 particles > µm (c) = 5 particles 6 / / Number of particles per ml Over 00 000 60 000 0 000 60 000 80 000 0 000 0 000 0 000 5 000 500 00 60 0 60 80 0 0 0 5.5. 0.6 0. 0.6 0.08 0.0 0.0 0.0 0 Up to 500 000 00 000 60 000 0 000 60 000 80 000 0 000 0 000 0 000 5 000 500 00 60 0 60 80 0 0 0 5.5. 0.6 0. 0.6 0.08 0.0 0.0 0.0 Number of particles per 00ml larger than indicated size 0 0 0 5.5. 6...6 8 6 5 5 0 New ISO 06 standard µm (c) Old standard 9 8 7 6 5 ISO Code numbers Introduction

CONTAMINATION MANAGEMENT - CUMULATIVE DISTRIBUTION OF THE PARTICLES SIZE - SAE AS 059- and SAE AS 059- Classification example according to SAE AS 059- and SAE AS 059- The code, prepared for the aerospace industry, is based on the size, quantity, and particle spacing in a 00 ml fluid sample. The contamination classes are defined by numeric codes, the size of the contaminant is identified by letters (A-F). It can be made a differential measurement (Table ) or a cumulative measurement (Table ) Class 00 0 5 6 7 8 9 0 Dimension of contaminant 6 µm (c) µm (c) 8 µm (c) 8 70 µm (c) >70 µm (c) 5 50 500 000 000 000 8 000 6 000 000 6 000 8 000 56 000 5 000 0 000 89 78 56 7 5 850 5 700 00 800 5 600 9 00 8 00 8 6 6 6 5 506 0 05 050 8 00 6 00 00 6 5 90 80 60 70 0 880 5 760 0 0 8 6 6 8 56 5 0 6 µm (c) = 5 000 particles µm (c) = 00 particles 8 µm (c) = 00 particles 8 70 µm (c) = 5 particles > 70 µm (c) = particles Class 6 Class 000 00 0 5 6 7 8 9 0 > µm (c) A 95 90 780 560 0 6 50 500 5 000 50 000 00 000 00 000 00 000 800 000 600 000 00 000 >6 µm (c) B 76 5 0 609 7 86 9 7 9 6 8 9 77 89 55 698 96 6 79 5 58 > µm (c) = 5 000 particles > 6 µm (c) = 5 000 particles > µm (c) = 500 particles > µm (c) = 50 particles > 8 µm (c) = 5 particles > 70 µm (c) = particle Class from F to E Table - Class for differential measurement Table - Class for cumulative measurement Dimension of contaminant > µm (c) C 7 5 09 7 86 7 6 6 9 89 7 698 55 96 0 79 58 > µm (c) D 5 0 0 9 76 5 06 6 9 898 9 796 9 59 9 8 >8 µm (c) E 7 6 5 06 88 696 9 6 78 >70 µm (c) F 0 0 0 8 6 6 8 56 5 0 - CLASSES OF CONTAMINATION ACCORDING TO NAS 68 (January 96) The NAS system was originally developed in 96 to define contamination classes for the contamination contained within aircraft components. The application of this standard was extended to industrial hydraulic systems simply because nothing else existed at the time. The coding system defines the maximum numbers permitted of 00ml volume at various size intervals (differential counts) rather than using cumulative counts as in ISO 06:999. Although there is no guidance given in the standard on how to quote the levels, most industrial users quote a single code which is the highest recorded in all sizes and this convention is used on MP Filtri APC s. The contamination classes are defined by a number (from 00 to ) which indicates the maximum number of particles per 00 ml, counted on a differential basis, in a given size bracket. Size Range Classes (in microns) Class 00 0 5 6 7 8 9 0 Maximum Contamination Limits per 00 ml 5 5 5 5 5 50 50 00 >00 5 50 500 000 000 000 8 000 6 000 000 6 000 8 000 56 000 5 000 0 000 89 78 56 7 5 850 5 700 00 800 5 600 9 00 8 00 5 5 µm (c) = 000 particles 5 5 µm (c) = 00 particles 5 50 µm (c) = 50 particles 50 00 µm (c) = 8 particles > 00 µm (c) = particles Class NAS 8 8 6 6 6 5 506 0 05 050 8 00 6 00 00 6 5 90 80 60 70 0 880 5 760 - CUMULATIVE DISTRIBUTION OF THE PARTICLES SIZE - ISO 07 0 0 8 6 6 8 56 5 0 The level of contamination is defined by counting the number of particles collected by a laboratory membrane per unit of fluid volume. The measurement is done by a microscope. The membrane must be cleaned, dried and desiccated, with fluid and conditions defined by the Standard. The fluid volume is filtered through the membrane, using a suitable suction system. The level of contamination is identified by dividing the membrane into a predefined number of areas and by counting the contaminant particles using a suitable laboratory microscope. MICROSCOPE CONTROL AND MEASUREMENT COMPARISON PHOTOGRAPH S graduation = 0µm ISO 06:999 SAE AS059E Table NAS 68 SAE AS059E Table Class 6// Class 5 Class 5 Class 6A/5B/5C Class /0/7 Class Class Class A/B/C 5 Introduction

CONTAMINATION MANAGEMENT - CLEANLINESS CODE COMPARISON Although ISO 06:999 standard is being used extensively within the hydraulics industry other standards are occasionally required and a comparison may be requested. The table below gives a very general comparison but often no direct comparison is possible due to the different classes and sizes involved. External protective wire mesh Pre-fi ltration layer Filtration layer Inner support layer Inner protective wire mesh ISO 06:999 / / 8 SAE AS059 Table > µm (c) µm (c) µm (c) 6 µm (c) > µm (c) 6 µm (c) A / B / C SAE AS059 Table -6 6- - -8 8-70 >70 NAS 68 5-5 5-5 5-50 50-00 >00 MICROFIBER FILTRATION Support S pipe / 0 / 7 / 9 / 6 0 / 8 / 5 9 / 7 / 8 / 6 / 7 / 5 / A / B / C A / 0B / 0C 0A / 9B / 9B 9A / 8B / 8C 8A / 7B / 7C 7A / 6B / 6C 0 9 8 7 6 0 9 8 7 6 The fi ltration effi ciency of metallic mesh fi ltrations is defi ned as the maximum particle size that can pass through the meshes of the fi ltering grid. The effi ciency of microfi bre and paper fi ltration (ß x(c) ) is defi ned through a lab test called Multipass Test. The effi ciency value (ß x(c) ) is defi ned as the ratio between the number of particles of certain dimensions detected upstream and downstream of the fi lter. 6 / / 6A / 5B / 5C 5 5 5 / / 0 / / 09 5A / B / C A / B / C Upstream particles number > X µm (c) = ß x(c) Downstream particles number > X µm (c) 5 FILTRATION TECHNOLOGIES Various mechanisms such as mechanical stoppage, magnetism, gravimetric deposit, or centrifugal separation can be used to reduce the level of contamination. The mechanical stoppage method is most effective and can take place in two ways: - SURFACE FILTRATION It is by direct interception. The fi lter prevents particles larger than the pores from continuing in the plant / system. Surface filters are generally manufactured with metal canvases or meshes. Value (ß x(c) ) Efficiency 50% 0 90% 75 98.7% 00 99% 00 99.5% 000 99.9% - DEPTH FILTERING Filters are constructed by fiber interlacing. Such wraps form pathways of different shapes and sizes in which the particles remain trapped when they fi nd smaller apertures than their diameter. Depth fi lters are generally produced with papers impregnated with phenolic resins, metal fi bers or inorganic fi bers. In inorganic fi ber fi ltration, commonly called microfi bre, the fi ltering layers are often overlapped in order to increase the ability to retain the contaminant. Test conditions, such as type of fl uid to be used (MIL-H-5606), type of contaminant to be used (ISO MTD), fl uid viscosity, test temperature, are determined by ISO 6889. In addition to the fi ltration effi ciency value during the Multipass test, other important features, such as fi ltration stability (ß stability) and dirt holding capacity (DHC), are also tested. Poor fi ltration stability is the cause of the fi ltering quality worsening as the fi lter life rises. Low dirt holding capacity causes a reduction in the life of the fi lter. WIRE MESH FILTRATION PAPER FILTRATION MP Filtri Filter media code A0 A06 A0 A6 A5 Filtration ISO Standard Comparison ß x(c) > 000 ISO 6889 5 µm (c) 7 µm (c) 0 µm (c) 5 µm (c) µm (c) Introduction 6

CONTAMINATION MANAGEMENT 6 RECOMMENDED CONTAMINATION CLASSES Any are the nature and the properties of fl uids, they are inevitably subject to contamination. The level of contamination can be managed by using special components called fi lters. Hydraulic components builders, knowing the problem of contamination, recommend the fi ltration level appropriate to the use of their products. Example of recommended contamination levels Piston pumps with fi xed fl ow rate Piston pumps with variable fl ow rate Vane pumps with fi xed fl ow rate Vane pumps with variable fl ow Engines Hydraulic cylinders Actuators Test benches Check valve Directional valves Flow regulating valves Proportional valves Servo-valves Flat bearings Ball bearings ISO 06 CODE Recommended fi ltration ßx(c).000 The common classifi cation of fi lters is determined by their position in the plant. Types of filters: 0/8/5 ß 0(c) >000 9/7/ ß 5(c) >000 8/6/ 7/5/ ß 0(c) ß 7(c) >000 >000 Suction filters They are positioned before the pump and are responsible for protecting the pump from dirty contaminants. It also provides additional fl ow guidance to the pump suction line. Being subject to negligible working pressures are manufactured with simple and lightweight construction. They are mainly produced with gross grade surface fi ltrations, mainly 60 5 µm. They can be equipped with a magnetic fi lter for retaining ferrous particles. They are generally placed under the fl uid head to take advantage of the piezometric thrust of the fl uid and reduce the risk of cavitation. There are two types of suction fi lters: - IMMERSION FILTERS Simple fi lter element screwed on the suction pipe 6// ß 7(c) >000 - FILTERS WITH CONTAINER Container fi lters that are more bulky, but provide easier maintenance of the tank 5//0 ß 5(c) >000 Delivery (or Pressure) filters They are positioned between the pump and most sensitive regulating and controlling components, such as servo valves or proportional valves, and are designed to ensure the class of contamination required by the components used in the circuit. Being subjected to high working pressures are manufactured with more robust and articulated construction. In particular situations of corrosive environments or aggressive fl uids can be made of stainless steel. They are mainly produced with fi ltering depths of 5 µm. They can be manufactured with in-line connections, with plate or fl ange connections or directly integrated into the circuit control blocks / manifolds. They can also be manufactured in duplex confi guration to allow the contaminated section to be maintained even when the plant / system is in operation without interruption of the working cycle. Return filters They are positioned on the return line to the tank and perform the task of fi ltering the fl uid from particles entering the system from the outside or generated by the wear of the components. They are generally fi xed to the reservoir (for this reason also called top tank mounted), positioned semi-immersed or completely immersed. They are mainly produced with fi ltration depths of 0 5 µm. The positioning of the return fi lters must guarantee in all operating conditions that the fl uid drainage takes place in immersed condition; this is to avoid creating foams in the tank that can cause malfunctions or cavitation in the pumps. For the sizing of the return fi lters, account must be taken of the presence of accumulators or cylinders that can make the return fl ow considerably greater than the pump suction fl ow rate. Being subject to contained working pressures are manufactured with simple and lightweight construction. Normally it is possible to extract the fi lter element without disconnecting the fi lter from the rest of the system. Combined filters They are designed to be applied to systems with two or more circuits. They are commonly used in hydrostatic transmission machines where they have a dual fi ltration function of the return line and suction line of the hydrostatic transmission pump. The fi lter is equipped with a valve that keeps the 0.5 bar pressure inside the fi lter. A portion of the fl uid that returns to the tank is fi ltered by the return fi lter element, generally produced with absolute fi ltration, and returns to the transmission booster pump. Only excess fl uid returns to the tank through the valve. The internal pressure of the fi lter and the absolute fi ltration help to avoid the cavitation phenomenon inside the pump. Off-line filters They are generally used in very large systems / plants, placed in a closed circuit independent from the main circuit. They remain in operation regardless of the operation of the main circuit and are crossed by a constant fl ow rate. They can also be manufactured in duplex confi guration to allow the contaminated section to be maintained even when the unit is in operation without interruption of the work cycle. Venting filters During the operation of the plants, the fl uid level present in the reservoir changes continuously. The result of this continuous fl uctuation is an exchange of air with the outside environment. The venting fi lter function, positioned on the tank, is to fi lter the air that enters the tank to compensate for fl uid level variations. 7 Introduction

CONTAMINATION MANAGEMENT FILTER CHOICE PARAMETERS 7 8 APPLICABLE STANDARDS FOR FILTER DEVELOPMENT The choice of the fi lter system for an hydraulic system is infl uenced by several factors. It is necessary to consider the characteristics of the various components present in the plant and their sensitivity to contamination. It is also necessary to consider all the tasks that the fi lter will have to do within the plant: - FLUID PROTECTION FROM CONTAMINATION - PROTECTION OF OLEODYNAMIC COMPONENTS SENSITIVE TO CONTAMINATION - PROTECTION OF OLEODINAMIC PLANTS FROM ENVIRONMENTAL WASTE - PROTECTION OF OLEODINAMIC PLANTS FROM CONTAMINATION CAUSED BY COMPONENTS FAILURES The advantages of proper positioning and sizing of the fi lters are - MORE RELIABILITY OF THE SYSTEM - LONGER LIFE OF THE FLUID COMPONENTS - REDUCTION OF STOP TIME - REDUCTION OF FAILURE CASUALITIES Each hydraulic fi lter is described by general features that identify the possibility of use in different applications. MAXIMUM WORKING PRESSURE (Pmax) The maximum working pressure of the filter must be greater than or equal to the pressure of the circuit section in which it will be installed. PRESSURE DROP (ΔP) The pressure drop depends on a number of factors, such as the working circuit temperature, the fl uid viscosity, the fi lter element cleaning condition. WORKING TEMPERATURE (T) The working temperature deeply affect the choice of materials. Excessively high or low temperatures may adversely affect the strength of the materials or the characteristics of the seals. FILTRATION EFFICIENCY (%) / FILTRATION RATIO (ß x(c) ) Filtration efficiency is the most important parameter to consider when selecting a fi lter. When choosing the filtration performances, the needs of the most sensitive components in the system must be considered. FLUID TYPE The type of fl uid infl uences the choice of fi lters in terms of compatibility and viscosity. It is always mandatory to check the fi lterability. PLACEMENT IN THE PLANT The position of the filter in the system conditions the efficiency of all filter performances. In order to obtain unique criteria for development and verification of the fi lters performance, specifi c regulations for the fi lters and fi lter elements testing have been issued by ISO. These norms describe the target, the methodology, the conditions and the presentation methods for the test results. ISO 9 Hydraulic fl uid power -- Filter elements -- Verifi cation of collapse/burst pressure rating This Standard describes the method for testing the collapse / burst resistance of the fi lter elements. The test is performed by crossing the contaminated fl uid fi lter element at a predefi ned fl ow rate. The progressive clogging of the fi lter element, determined by contamination, causes an increase in differential pressure. ISO 9 Hydraulic fl uid power -- Filter elements -- Verifi cation of fabrication integrity and determination of the fi rst bubble point This Standard describes the method to verify the integrity of the assembled fi lter elements. It can be used to verify the quality of the production process or the quality of the materials by verifying the pressure value of the fi rst bubble point. ISO 9 Hydraulic fl uid power -- Filter elements -- Verifi cation of material compatibility with fl uids This Standard describes the method to verify the compatibility of materials with certain hydraulic fl uids. The test is carried out by keeping the element (the material sample) immersed in the fl uid under high or low temperature conditions for a given period of time and verifying the retention of the characteristics. ISO 7 Hydraulic fl uid power -- Filter elements -- Method for end load test This Standard describes the method for verifying the axial load resistance of the fi lter elements. After performing the procedure described in ISO 9, the designed axial load is applied to the fi lter element. To verify the test results, then the test described in ISO 9 is performed. ISO 968 Hydraulic fl uid power -- Filters -- Evaluation of differential pressure versus fl ow characteristics This Standard describes the method for checking the pressure drop across the fi lter. The test is carried out by crossing the fi lter from a given fl uid and by detecting upstream and downstream pressures. Some of the parameters defi ned by the Standard are the fl uid, the test temperature, the size of the tubes, the position of the pressure detection points. ISO 6889 Hydraulic fl uid power -- Filters -- Multi-pass method for evaluating fi ltration performance of a fi lter element This Standard describes the method to check the fi ltration characteristics of the fi lter elements. The test is performed by constant introduction of contaminant (ISO MTD). The characteristics observed during the test are the fi ltration effi ciency and the dirty holding capacity related to the differential pressure. Introduction 8

CONTAMINATION MANAGEMENT ISO 8 Hydraulic fluid power -- Filter elements -- Determination of resistance to flow fatigue using high viscosity fluid This Standard describes the method for testing the fatigue resistance of the filter elements. The test is carried out by subjecting the filter to continuous flow variations, thus differential pressure, using a high viscosity fluid. ISO 70 Hydraulic fluid power -- Sequence of tests for verifying performance characteristics of filter elements The Standard describes the method for testing the performance of filter elements. The protocol described by the regulations provides the sequence of all the tests described above in order to verify all the working characteristics (mechanical, hydraulic and filtration). ISO 077- Hydraulic fluid power -- Fatigue pressure testing of metal pressure-containing envelopes -- Test method This Standard describes the method to check the resistance of the hydraulic components with pulsing pressure. It can be applied to all metal components (excluding tubes) subject to cyclic pressure used in the hydraulic field. 9 Introduction

FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending by the application. For example, for the return filter the pressure drop have to be in the range 0. - 0.6 bar. The pressure drop calculation is performed by adding together the value of the housing with the value of the filter element. The pressure drop in the housing is proportional to the fluid density (kg/dm ); all the graphs in the catalogue are referred to mineral oil with density of 0.86 kg/dm. The filter element pressure drop is proportional to its viscosity (mm /s), the corrective factor Y is related to an oil viscosity different than 0 mm /s. Sizing data for single cartridge, head at top pc = Filter housing pressure drop [bar] pe = Filter element pressure drop [bar] Y = Multiplication factor Y (see correspondent table), depending on the filter element size, on the filter element lenght and on the filter media Q = flow rate (l/min) V reference viscosity = 0 mm /s (cst) V = operating viscosity in mm /s (cst) pe = Y : 000 x Q x (V/V) p Tot. = pc + pe Calculation examples with HLP Mineral oil Variation in viscosity Application data: Top tank return filter Filter with in-line connections Pressure Pmax = 0 bar Flow rate Q = 0 l/min Viscosity V = 6 mm /s (cst) Oil viscosity = 0.86 kg/dm Required filtration efficiency = 5 μm with absolute filtration With bypass valve and / inlet connection From the working pressure and the flow rate we understand it should be possible using the following top tank return filter series: MPT, MPH and FRI. Let s proceed with MPT series. The size 0 doesn t achieve the required flow rate, therefore we have to consider the size 00. The final version of size 00 (0, 0, 0, 0 and ) will be then defined in function of the mounting characteristics. pc = 0.0 bar ( see graphic below, considering size 00 with the max available lenght * to get the lowest pressure drop) pe = (.0 : 000) x 0 x (6/0) = 0.7 bar p Tot. = 0.0 + 0.7 = 0. bar The selection is correct because the total pressure drop value is inside the admissible range for top tank return filters. It is of course possible trying to find a different solution, according to the mounting position or to other commercial need, repeating the previous steps while using a different series or lenght. Δp bar MPT 0 - Length - 0.0 0.0 0.0 0.0 0 * G / 0 60 0 80 0 00 Flow rate l/min Filter housings p pressure drop. The curves are plotted using mineral oil with density of 0.86 kg/dm in compliance with ISO 968. p varies proportionally with density. Corrective factor Corrective factor Y, to be used for the filter element pressure drop calculation. The values depend to the filter size and lenght and to the filter media. Reference viscosity 0 mm /s Return filters Filter element Type MF 00 MF 00 MFX 00 MF 00 MFX 00 MF 80 MFX 80 MF 90 MFX 90 MF 00 MFX 00 MF 750 MFX 750 CU 05 CU 00 CU 00 CU 50 CU 60 CU 850 MR 00 MR 50 MR 60 MR 850 5 5 A0 7.00 9.0.00 7.00 8.0 7. 0.5 6.0.67.69.69.0.00.90.08 78.00 5.88 5.0.5.96.06 9.00.70 7.80 5.50.0 5.5.00.60.8.0.06.8.0 0.7 0.60 0.7 0.7 0. Absolute filtration Nominal filtration H Series N Series A06 A0 A6 A5 P0 P5 M5 M60 M90 50.08 0.00 6.00 9.00 6. 5.5.0. 8.00 7. 5.00..85.00 9.00 6.56 5...68..0 50.08.0.50 9.00 5.0.05.7.7.75.87.60 0.8 8.00 0.88.5.55.68 0.8 7.00 0.80 6.87.97.8.85.8.0.56.8.9.0.0 0.65 0. 0.6 0.8 0.6 0.00 8.67 6.86.65.0.6 0.68 0.60.9 0.88 0.6 0.9 8.00 0. 5..55 0.85 0. 6.90.0.70.60.6...08 0.68. 0.8 0.60 0.8 0.0 0. 0. 0.7 0. 6.00 8.7 5.70..0.56 0.5 0.9. 0.85 0.5 0.6.00 0.00.95.5 0.7 0. 6.0.0.0.0.5.9.0.00 0.56. 0.76 0.56 0.0 0.8 0.5 0. 0.7 0. 9.00 6.88.00.50.00. 0.5 0..06 0.55 0.9 0.6 9..78.00 0.7 0. 0.7.60.00.70.8.90.50.07 0.86 0. 0.9 0.8 0.6 0.5 0. 0. 0. 0.05 0.0 6..6.05.6.9.8 0. 0.5 0.96 0.9 0.9 0. 9..78.00 0.7 0. 0.7.9.9..7.60.8 0.96 0.77 0.7 0.8 0. 0. 0. 0.0 0. 0.08 0.0 0.0 5.5.96.7. 0.96.06 0.9 0. 0.87 0.5 0.5 0.9 8.5.0 0.7 0.59 0.6 0..5.5.8.7.7.0 0.8 0.6 0. 0.7 0.7 0.7 0.6 0.08 0.09 0.07 0.0 0.0.0.5.0 0.96 0.8 0.6 0. 0. 0. 0. 0. 0.06.5.5.0 0.5 0.09 0.0.60.7... 0.5 0. 0. 0. 0.09 0.08 0.08 0.08 0.0 0.0 0.0 0.0 0.0 Introduction 0

Corrective factor Corrective factor Y, to be used for the filter element pressure drop calculation. The values depend to the filter size and lenght and to the filter media. Reference viscosity 0 mm /s Suction filters Filter element Type SF 50 Nominal filtration N Series P0 P5 65 Low & Medium pressure filters Filter element Type CU 0 A0 6.5.6 8.57 5.76 FILTER SIZING Absolute filtration Nominal filtration N-W Series N Series A06 A0 A6 A5 P0 P5 M5 5.6 0. 7.95.05 8.75 6. 5.07.80 8. 6.0.07.6 5.87.5.0..86.60. 0.9.65.9.5 0.85 0. 0. 0. 0.05 Return / Suction filters Filter element Type RSX 6 A0 5.. Absolute filtration A6..87 A5.85. CU 0 DN 06 05 00 5.0..0 7.95 5.00..80.95.70 7.0.5.66.00. 0.9.00.89..66.09 0.8.9.57 0.98. 0.70 0.5.98.5 0.6 0.56 0. 0. 0.8 0.5 0.8 0. 0.5 0. 0.65 0. 0. 0. 0.09 0.05 0.8 0. 0.08 RSX 65.06. 0.9.75.05 0.86.6 0.96 0.6 CU 00 5 6..5.60.00 0.8.55.70.8 0.8 0.58.6 0.9 0.7 0.7 0.0. 0.78 0.6 0. 0.7 0.78 0.50 0.0 0.0 0.7 0.75 0.0 0. 0. 0. 0.6 0. 0.7 0.9 0.8 0.9 0.0 0.08 0.06 0.05 CU 900 0.86 0.6 0. 0.0 0. - - 0.05 CU 950.0 0. 0.80 0.0 0.59 0.7 0.0 0.8 0.6 0.5 - - - - 0.05 0.0 MR 60 7 0.88 0.78 0.6 0. 0.6 0. 0.96 0.7 Introduction

FILTER SIZING Corrective factor Corrective factor Y, to be used for the filter element pressure drop calculation. The values depend to the filter size and lenght and to the filter media. Reference viscosity 0 mm /s High pressure filters Filter element Type HP 0 A0.7 0.8. 77.76 Absolute filtration N - R Series A06 A0 A6 50.07 65.56 9.68 58.5 8. 7.08.8 8.7 5.6 59..08.67 A5 8.6 7.05 0.7 6.7 Nominal filtration N Series M5 - - - - Stainless steel high pressure filters Filter element Type HP 0 A0.7 0.8. 77.76 Absolute filtration N Series A06 A0 A6 50.07 65.56 9.68 58.5 8. 7.08.8 8.7 5.6 59..08.67 A5 8.6 7.05 0.7 6.7 HP 09 70.66 6.57 6.57 5.0.8.7 5.77 8.00.6 0.57.8 8.80.67 8.00 5.58.90.90.0 HP 09 70.66 6.57 6.57 5.0.8.7 5.77 8.00.6 0.57.8 0.88.67 8.00 5.58 HP 050 5.75.5 7.7. 7.00 0.0.6 6.5 0.75 6.56.6.70 8.90 6.0.60. 9.09 7.8 5.75.0 7.9.90.6.08.5.60.0.5.07 0.80 HP 050 5.75.5 7.7. 7.00 0.0.6 6.5 0.75 6.56.6.70 8.90 6.0.60. 9.09 7.8 5.75.0 7.9.90.6.08.5 HP 065 58.50.60 0.50.6 5.6 5.88.6 6. 8.8 9.66.88 6.8 0.7 7..9.8. 0.58 HP 5 0.. 6.8 8.80 0.6 6. 9.7 6.60.8 8.66 6.8.6.78.. HP 5 HP 0 0.. 6.8 0.88.0.75. 8.80 0.6 6. 9.7.8..77 9.7 6.60.8 5.0.75.05 0.98 8.66 6.8.6.7.8 0.87 0.78.78...5 0.88 0.77 0.55.78..0.0 0.7 0.6 0.7 Filter element Type HP 0 A0.58 8.06 0. 09.9 Absolute filtration H - U Series A06 A0 A6 9.7.5 97.50 8.5 5.7 9.5.6 6.79 9. 75.5.8 9.7 A5 6.78 7.6.8 8.0 HP 500 5..7..8..67.77.98..5.0.78. 0.9 0.77.0.68.09 0.86 0.68.65. 0.75 0.68 0.8 0.5 0.0 0.08 0.05 0.0 HP 09 70.66 6.57 6.57 5.0.8.7 5.77 8.00.6 0.57.8 8.80.67 8.00 5.58 Filter element Type A0 Absolute filtration N Series A06 A0 A6 A5 Nominal filtration N Series M5 HP 050 5 7. 9.0 0.85.55 9.86.5 5.95 9.50.90 9..50.0 0.68 7. 6.0 0.50 0.90 8.6 6.90.80.7 5.88.6.69.50 HF 0.65.0.8.95.7..80.6..80.5. 0.90 0.85 0.80 0.8 0.6 0.5 HP 5 9.6.8 8.96 5..0 7.6.00 7.86.89.7 7.60.6 5.9..07 Introduction

Selection Software FILTER SIZING Step Select FILTERS Step Choose fi lter group (Return Filter, Pressure Filter, etc.) Step Choose fi lter type (MPF, MPT, etc.) in function of the max working pressure and the max fl ow rate Step Push PROCEED Step 5 Insert all application data to calculate the fi lter size following the sequence: - working pressure - working fl ow rate - working pressure drop - working temperature - fl uid material and fl uid type - fi ltration media - connection type Step 6 Push CALCULATE to have result; in case of any mistake, the system will advice which parameter is out of range to allow to modify/adjust the selection Step 7 Download PDF Datasheet Report.aspx pushing the button Drawing Introduction

LMP - low and medium pressure filters are used as process filters to protect pumps, pressure reducers and hydraulic circuits from damage due to oil contamination as per ISO 06. LMP series is available in 5 different sizes: 00, 00, 00, 900 and 950 and a wide range of versions. LMP filters are available with several working pressures suitable for all hydraulic circuits as: - return filters in external tank mounting construction for medium and high flow rates in single and duplex versions - in-line filters for low and medium pressures for off-line applications - in-line process filters for medium pressures, for example, for forced lubrication applications, in single or duplex versions - in-line filters for medium pressures for filtering hydraulic boost circuits - in-line filters as high holding capacity filters on test beds LMP filters are thus specifically designed to be suitable for a wide range of application: from steel plants to mobile equipments, from test benches to naval application, providing the right solution for filtering requirements in all sectors. LMP filters are available in single, manifold and duplex versions. FILTER SIZING For the proper corrective factor Y see chapter at page Low & Medium Pressure filters 0

Low & Medium Pressure filters LMP 0-0 MULTIPORT LMP 0 - LMP 00-0 - 0 - LMP 900-90 LMP 90-90 LMP 950-95 LMP 95-95 - 95 page 05 LMD LMD 00-0 - LMD 95 page 79 87 0 5 LDP - LDD page 09 Filter element according to DIN 550 59 67 INDICATORS page 8 0 Low & Medium Pressure filters

Low & Medium Pressure filters 0

Low & Medium Pressure fi lters LMP 0-0 series MULTIPORT Maximum pressure up to 80 bar - Flow rate up to 00 l/min 05 Low & Medium Pressure filters

LMP 0-0 MULTIPORT GENERAL INFORMATION Technical data Low & Medium Pressure filters Maximum pressure up to 80 bar - Flow rate up to 00 l/min Filter housing materials - Head: Aluminium - Housing: Cataphoresis - Painted Steel - Bypass valve: Brass - Aluminium Seals - Standard NBR series A - Optional FPM series V Pressure - Working pressure: 8 MPa (80 bar) - Test pressure: MPa (0 bar) - Burst pressure: LMP 0: 9 MPa (90 bar) LMP 0/0: 8 MPa (80 bar) - Pulse pressure fatigue test: 000 000 cycles with pressure from 0 to 8 MPa (80 bar) Temperature From -5 C to +0 C Note LMP MULTIPORT filters are provided for vertical mounting Bypass valve - Opening pressure.5 bar ±0% - Other opening pressures on request. p element type - Microfibre filter elements - series N - W: 0 bar - Wire mesh filter elements - series N: 0 bar - Fluid flow through the filter element from OUT to IN. Weights [kg] and volumes [dm ] LMP 0 LMP 0 LMP Length Weights [kg].60.80.0.60.90.0.0.90.70.90.0.70 Length Volumes [dm ] 0.75 0.8..5 0.75 0.8..5 0.75 0.8..5 Low & Medium Pressure filters 06

GENERAL INFORMATION LMP 0-0 MULTIPORT Multiport LMP 0 LMP 0 In-Line fi lter Port IN-OUT on the same side LMP Double IN port LMP Lateral OUT port high fl ow LMP 6 Double OUT port Type LMP Bypass valve for heat exchanger high fl ow C B A LMP 8 Bypass lateral. Always cleaning fl uid in OUT port Type C B A LMP 9 Safety valve 6 bar for heat exchanger 07 Low & Medium Pressure filters

LMP 0 LMP 0 0.9 0.9 / LMP / / 0.9 / 0.6 0.6 LMP 0-0 0.6 MULTIPORT LMP 8-9 0.90. 0. LMP 8 - Setting.5 bar The curves are plotted using mineral oil 8 Pressure drop / / with density of 0.86 kg/dm in compliance with ISO 968. 0. p varies proportionally with density. 0 0.60 0 0 80 0 60 00 0 0 80 0 60 00 0 Flow rate l/min Flow rate l/min 0 0 80 0 60 00 0. 6 Flow rate l/min Δp bar Δp bar 0 0.9 LMP LMP 0 0.90 0 80 0 60 00 / Flow rate OUT / l/min OUT / 0.6 0.6 LMP LMP 0 8 - Setting.5 bar 0.9 8 / 0. 0. 0.6 Δp Δp bar bar Δp bar Δp bar Δp bar Δp bar Δp bar 0 0.6 0 0 0 80 60 0 90 60 0 00 50 Flow Flow rate rate l/min l/min 0 0 0 0 00 800 060 6080 00 00 Flow rate l/min LMP 6 0.9 IN LMP 0 - - Setting.5 bar 0.99 LMP / - 0.6 A>C A>B 0.66 0. 0. 0 0 0 60 90 0 50 0 0 Flow rate l/min 0 0 0 0 80 80 0 0 60 60 00 00 Flow Flow rate rate l/min l/min Δp bar Δp bar Δp bar Δp bar Δp Δp bar bar A>C A>B GENERAL INFORMATION 0.6 Filter housings Valves Valves p pressure drop 0 LMP Bypass valve pressure drop Bypass valve pressure drop 0.9 0 0 0 60 80 00 OUT OUT Flow LMP rate 0 / l/min - - 6-8 - 0-6 - 8-9 - Setting.5 bar LMP - Filter housing wit 0.6 LMP 0 - - Setting.5 bar 9 8 88 0. 6 0 0 0 60 90 0 50 0Flow rate l/min 0 0 80 0 60 00 0 Flow rate l/min 0 0 80 0 60 00 Flow rate l/min 0.9 LMP LMP 8 6-9 LMP 0 - Setting 6 bar 0.9 8 / / IN / - 0.6 0.6 0. 0. Δp bar Δp bar Δp bar 6 0 0 0 0 0 060 80 0 90 6 60 0 96 00 50 8 60 Flow Flow rate rate l/min l/min Flow rate l/min Δp bar LMP 0.9 0. 0 Δp Δp bar bar 0 0 80 Flow rate 00 0 0 0 80 80 Flow Flow rate LMP 0 - Setting 6 bar 8 LMP - Filter housing wi 8 Δp Δp bar bar 6 0 0 0 0 6 80 Flow Flow rate rat Valves Bypass valve LMP 0 0.9pressure drop / LMP 0 - - 6-8 - 9 - Setting.5 bar 0.6 Δp bar Δp bar 8 0. 0 0 0 80 0 60 00 0 Flow rate l/min 0 0 80 0 60 00 Flow rate l/min Δp bar Δp bar LMP 0.9 A>C LMP - Filter housing with bar check valve A>B 0.6 8 0. A>C A>B 0 0 0 80 0 60 00 0 Flow rate l/min 0 0 80 0 60 00 es Flow rate l/min LMP LMP 0 - - Setting Filter housing 6 bar with bar check valve 8 A>C 8 Δp bar Δp bar 6 A>B Δp bar 8 LMP - Filter housing with bar check valve A>C A>B 0 0 0 0 0 680 96 0 8 60 60 00 Flow Flow rate rate l/min 0 0 0 80 0 60 00 Flow rate l/min Δp bar 8 LMP - Filter housing with bar check valve A>C A>B 0 0 0 80 0 60 00 Flow rate l/min Low & Medium Pressure filters 08

GENERAL INFORMATION The curves are plotted using mineral oil with density of 0.86 kg/dm in compliance with ISO 968. p varies proportionally with density. LMP 0-0 MULTIPORT Pressure drop LMP 0 - - 6-8 - 9 - Setting.5 bar 8 LMP 8 - Setting.5 bar Bypass valve pressure drop Δp bar 8 Δp bar 6 0 0 0 80 0 60 00 Flow rate l/min 0 0 0 0 60 80 00 Flow rate l/min Flow rate l/min 9 LMP 0 - - Setting.5 bar Δp bar 6 0 0 0 80 0 60 00 Flow rate l/min 09 Low & Medium Pressure filters

LMP MULTIPORT Designation & Ordering code LMP0 - LMP - LMP6 Series and size LMP0 LMP LMP6 Length Bypass valve S Without bypass B.5 bar Seals and treatments A NBR V FPM W NBR compatible with fluids HFA-HFB-HFC COMPLETE FILTER Configuration example: Filtration rating Axx Mxx Pxx LMP B A D A0 N P0 Connections A G/ B G C / NPT D NPT E SAE - /6 - UN F SAE 6-5/6 - UN Aux (only LMP - 6) G/ G/ / NPT / NPT SAE - /6 - UN SAE - /6 - UN Connection for differential indicator Without With standard connection With connection on the opposite side 6 With two connections on both sides Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized Element series and size CU0 FILTER ELEMENT Configuration example: CU0 A0 A N P0 Element length Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Seals A NBR V FPM W NBR Filtration rating Axx Mxx Pxx compatible with fluids HFA-HFB-HFC Element p N 0 bar Additional features page T Plug ACCESSORIES Execution P0 MP Filtri standard Pxx Customized Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Low & Medium Pressure filters 0

LMP0 - LMP - LMP6 LMP MULTIPORT Dimensions LMP0 - LMP LMP6 Filter length H [mm] 8 5 65 65 Recommended clearance space for maintenance Low & Medium Pressure filters

LMP MULTIPORT Designation & Ordering code LMP8 - LMP9 Series and size LMP8 LMP9 Length Bypass valve B.5 bar Seals and treatments A NBR V FPM W NBR compatible with fluids HFA-HFB-HFC COMPLETE FILTER Configuration example: Filtration rating Axx Mxx Pxx LMP8 B A D A0 N P0 Connections A G/ B G C / NPT D NPT E SAE - /6 - UN F SAE 6-5/6 - UN Aux OUT G/ G/ / NPT / NPT SAE - /6 - UN SAE - /6 - UN Connection for differential indicator Without With standard connection Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized Element series and size CU0 FILTER ELEMENT Configuration example: CU0 A0 A N P0 Element length Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Seals A NBR V FPM W NBR Filtration rating Axx Mxx Pxx compatible with fluids HFA-HFB-HFC Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized ACCESSORIES Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Additional features page T Plug Low & Medium Pressure filters

LMP8 - LMP9 LMP MULTIPORT Dimensions LMP8 - LMP9 Filter length H [mm] 8 5 65 65 Recommended clearance space for maintenance Low & Medium Pressure filters

LMP MULTIPORT Designation & Ordering code LMP0 - LMP Series and size LMP0 LMP Length Bypass valve S Without bypass B.5 bar Seals and treatments A NBR V FPM W NBR compatible with fluids HFA-HFB-HFC COMPLETE FILTER Configuration example: Filtration rating Axx Mxx Pxx LMP B A D A0 N P0 Connections A G/ B G C / NPT D NPT E SAE - /6 - UN F SAE 6-5/6 - UN LMP0 LMP Connection for differential indicator Without With standard connection Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized Element series and size CU0 FILTER ELEMENT Configuration example: CU0 A0 A N P0 Element length Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Seals A NBR V FPM W NBR Filtration rating Axx Mxx Pxx compatible with fluids HFA-HFB-HFC Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized ACCESSORIES Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Additional features page T Plug Low & Medium Pressure filters

LMP0 - LMP Filter length LMP MULTIPORT LMP0 Dimensions H [mm] 8 5 65 65 Connections A - B C - D - E - F R M0 /8 UNC Recommended clearance space Recommended for maintenance clearance space for maintenance Filter length LMP H [mm] 8 5 65 65 Connections B D - F R M0 /8 UNC Recommended clearance space for maintenance 5 Low & Medium Pressure filters

LMP MULTIPORT LMP Designation & Ordering code Series and size LMP Length COMPLETE FILTER Configuration example: LMP R A F A0 N P0 Valves C D G H M N Q R Bypass OUT to cooler Check valve without front bar bar side bar bar.5 bar front bar bar side bar bar Seals and treatments A NBR V FPM W NBR compatible with fluids HFA-HFB-HFC Filtration rating Axx Mxx Pxx Connections B F G SAE 6-5/6 - UN Connection for differential indicator Without With standard connection Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized Element series and size CU0 FILTER ELEMENT Configuration example: CU0 A0 A N P0 Element length Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Seals A NBR V FPM W NBR Filtration rating Axx Mxx Pxx compatible with fluids HFA-HFB-HFC Element p N 0 bar Additional features page T Plug ACCESSORIES Execution P0 MP Filtri standard Pxx Customized Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Low & Medium Pressure filters 6

LMP Filter length LMP MULTIPORT LMP Dimensions H [mm] 8 5 65 65 Connections B F R M0 /8 UNC Recommended clearance space for maintenance 7 Low & Medium Pressure filters

LMP 0-0 MULTIPORT Order number for spare parts SPARE PARTS LMP 0 - - 6-8 - 9 LMP 0 LMP - c d d c d c a a a b b b Item: Filter series LMP 0 - - 6-8 - 9 LMP 0 LMP - Q.ty: pc. Q.ty: pc. Q.ty: pc. (a d) Filter Seal Kit code number Indicator connection plug element NBR FPM NBR FPM See order table 005078 005079 TH TV Low & Medium Pressure filters 8

LMP 0-0 MULTIPORT 9 Low & Medium Pressure filters

Low & Medium Pressure filters 0

Low & Medium Pressure fi lters LMP 0- Maximum pressure up to 60 bar - Flow rate up to 0 l/min Low & Medium Pressure filters

LMP0- GENERAL INFORMATION Technical data Low & Medium Pressure filters Maximum pressure up to 60 bar - Flow rate up to 0 l/min Filter housing materials - Head: Aluminium - Bowl: Cataphoretic Painted Steel - Bypass valve: AISI 0 - Nylon Seals - Standard NBR series A - Optional FPM series V Pressure - Working pressure: 6 MPa (60 bar) - Test pressure: 9 MPa (90 bar) - Burst pressure: MPa (0 bar) - Pulse pressure fatigue test: 000 000 cycles with pressure from 0 to 6 MPa (60 bar) Temperature From -5 C to +0 C Connections Inlet/Outlet In-Line Bypass valve - Opening pressure.5 bar ±0% - Other opening pressures on request. Note LMP 0 - filters are provided for vertical mounting p element type - Microfibre filter elements - series N: 0 bar - Fluid flow through the filter element from OUT to IN. Weights [kg] and volumes [dm ] Weights [kg] Volumes [dm ] Length Length LMP 0 -.0.80 6.0.60.0.80 Hydraulic symbols LMP 0-00-900-950 execution S LMP 0-00-900-950 execution B Low & Medium Pressure filters

GENERAL INFORMATION LMP0- The curves are plotted using mineral oil with density of 0.86 kg/dm in compliance with ISO 968. p varies proportionally with density. Pressure drop 0.9 0.6 LMP 0 Δp Housing / / 0.9 0.6 LMP Δp Housing / / Filter housings p pressure drop Δp bar 0. Δp bar 0. 0 0 80 60 0 0 00 Flow rate l/min 0 0 80 60 0 0 00 Flow rate l/min 9 LMP 0/ Bypass valve pressure drop Δp bar 6 0 0 00 00 00 00 500 Flow rate l/min Low & Medium Pressure filters

LMP0 Designation & Ordering code COMPLETE FILTER Series and size LMP0 Configuration example: LMP0 B A F A0 N P0 Length Bypass valve S Without bypass B.5 bar Seals and treatments A NBR V FPM W NBR compatible with fluids HFA-HFB-HFC Filtration rating Axx Mxx Pxx Connections F SAE 000 psi/m F / SAE 000 psi/m F / SAE 000 psi/m F SAE 000 psi/unc F5 / SAE 000 psi/unc F6 / SAE 000 psi/unc Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized Element series and size CU0 FILTER ELEMENT Configuration example: CU0 A0 A N P0 Element length Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Seals A NBR V FPM W NBR Filtration rating Axx Mxx Pxx compatible with fluids HFA-HFB-HFC Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized ACCESSORIES Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Additional features page T Plug Low & Medium Pressure filters

LMP0 Filter length LMP0 Dimensions H [mm] 6 9 6 Connections F - F - F F - F5 - F6 R M8 5/6 UNC Drain plug only length Recommended clearance space for maintenance 5 Low & Medium Pressure filters

LMP Designation & Ordering code Series and size LMP Length Bypass valve S Without bypass Seals and treatments A NBR V FPM W NBR compatible with fluids HFA-HFB-HFC Connections A G B G / C G / D NPT E / NPT F / NPT G SAE 6-5/6 - UN H SAE 0-5/8 - UN I SAE - 7/8 - UN Connection for differential indicator 6 With plugged connection B.5 bar COMPLETE FILTER Configuration example: Filtration rating Axx Mxx Pxx LMP B A D 6 A0 N P0 Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized Element series and size CU0 FILTER ELEMENT Configuration example: CU0 A0 A N P0 Element length Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Seals A NBR V FPM W NBR Filtration rating Axx Mxx Pxx compatible with fluids HFA-HFB-HFC Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized ACCESSORIES Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Additional features page T Plug Low & Medium Pressure filters 6

LMP Filter length LMP Dimensions H [mm] 58 88 69 Connections A-B-C D-E-F-G-H-I R M8 5/6 UNC Drain plug only length Recommended clearance space for maintenance 7 Low & Medium Pressure filters

LMP0- Order number for spare parts SPARE PARTS LMP 0 LMP c c d d a a b b Item: Filter series LMP 0 - Q.ty: pc. Q.ty: pc. Q.ty: pc. (a d) Filter Seal Kit code number Indicator connection plug element NBR FPM NBR FPM See order table 00505 00506 TH TV Low & Medium Pressure filters 8

LMP0-9 Low & Medium Pressure filters

Low & Medium Pressure filters 0

Low & Medium Pressure fi lters LMP 00-0 & 0- series Maximum pressure up to 60 bar - Flow rate up to 70 l/min Low & Medium Pressure filters

LMP00-0& 0- GENERAL INFORMATION Technical data Low & Medium Pressure filters Maximum pressure up to 60 bar - Flow rate up to 70 l/min Filter housing materials - Head: Anodized Aluminium - Housing: Anodized Aluminium - Bypass valve: Steel Seals - Standard NBR series A - Optional FPM series V Pressure LMP 00 length - - - Working pressure: 6 MPa (60 bar) - Test pressure: 9 MPa (90 bar) - Burst pressure: MPa (0 bar) - Pulse pressure fatigue test: 000 000 cycles with pressure from 0 to 6 MPa (60 bar) Pressure LMP 00 length 5-6 - Working pressure: 5 MPa (50 bar) - Test pressure: 7.5 MPa (75 bar) - Burst pressure: 5 MPa (50 bar) - Pulse pressure fatigue test: 000 000 cycles with pressure from 0 to 5 MPa (50 bar) Temperature From -5 C to +0 C Connections LMP 00-0: In-line Inlet/Outlet LMP 0 - : 90 Inlet/Outlet Note LMP 00 filters are provided for vertical mounting Bypass valve - Opening pressure.5 bar ±0% - Other opening pressures on request. p element type - Microfibre filter elements - series N - W: 0 bar - Fluid flow through the filter element from OUT to IN. Weights [kg] and volumes [dm ] LMP 00-0 - 0 - Length Weights [kg] 5 6 7.0 8.0 8.80.90.0 Volumes [dm ] Length 5 6.50 5.00 6.50 9.50.50 Hydraulic symbols LMP 0-00-900-950 execution S LMP 0-00-900-950 execution B Low & Medium Pressure filters

GENERAL INFORMATION LMP00-0& 0- The curves are plotted using mineral oil with density of 0.86 kg/dm in compliance with ISO 968. p varies proportionally with density. Pressure drop 0.9 LMP 00-0 - 0 - Filter housings p pressure drop Δp bar 0.6 0. G G - F F 0 0 80 60 50 70 900 Flow rate l/min 9 LMP 00-0 - 0 - Bypass valve pressure drop Δp bar 6 0 0 0 80 0 560 700 Flow rate l/min EXECUTION P Execution P0 Internal tube for reduced flow rate is recommended for flow rate values below 00/50 I/min. The use of option P0 makes it easier to fill the housing with the operating fluid. Internal tube for reduced flow rates Low & Medium Pressure filters

LMP00-0 Designation & Ordering code COMPLETE FILTER Series and size LMP00 LMP0 Configuration example: LMP0 B A G A0 N P0 Length 5 6 Bypass valve S Without bypass B.5 bar Seals and treatments A NBR V FPM W NBR compatible with fluids HFA-HFB-HFC Filtration rating Axx Mxx Pxx Connections G G/ G G G / NPT G NPT G5 SAE - 7/8 - UN G6 SAE - / - UN F F F F SAE 000 psi/m / SAE 000 psi/m SAE 000 psi/unc / SAE 000 psi/unc Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Element p N 0 bar Execution P0 MP Filtri standard P0 Maintenance from the bottom of the housing Pxx Customized Filter length 5 6 Element series and size CU00 FILTER ELEMENT Configuration example: CU00 A0 A N P0 Element length 5 6 Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Seals A NBR V FPM W NBR Filtration rating Axx Mxx Pxx compatible with fluids HFA-HFB-HFC Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized ACCESSORIES Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Additional features page T Plug Low & Medium Pressure filters

LMP00-0 LMP00 Dimensions Length - - Filter H length [mm] 78 78 578 Connections G-G G-G-G5-G6 F-F F-F Recommended clearance space for maintenance Recommended clearance space for maintenance R M / UNC M / UNC Filter length 5 6 LMP00 Length 5-6 H [mm] H Execution [mm] P0 P0 88 0 660 58 0 690 Connections G-G G-G-G5-G6 F-F F-F R M / UNC M / UNC H - Recommended clearance space for maintenance 5 Low & Medium Pressure filters

LMP00-0 Dimensions LMP0 Length - - Filter H length [mm] 78 78 578 Connections G-G G-G-G5-G6 F-F F-F R M / UNC M / UNC Recommended clearance space for maintenance Recommended clearance space for maintenance Filter length 5 6 LMP0 Length 5-6 H [mm] H Execution [mm] P0 P0 88 0 660 58 0 690 Connections G-G G-G-G5-G6 F-F F-F R M / UNC M / UNC H - Recommended clearance space for maintenance Low & Medium Pressure filters 6

LMP00-0 7 Low & Medium Pressure filters

LMP0- Designation & Ordering code COMPLETE FILTER Series and size LMP0 LMP Configuration example: LMP 5 B A G A0 N P0 Length 5 6 Bypass valve S Without bypass B.5 bar Seals and treatments A NBR V FPM W NBR compatible with fluids HFA-HFB-HFC Filtration rating Axx Mxx Pxx Connections G G / G G G / NPT G NPT G5 SAE - 7/8 - UN G6 SAE - / - UN F F F F SAE 000 psi/m / SAE 000 psi/m SAE 000 psi/unc / SAE 000 psi/unc Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Element p N 0 bar Execution P0 MP Filtri standard P0 With internal reduced flow rate tube Pxx Customized Element series and size CU00 FILTER ELEMENT Configuration example: CU00 5 A0 A N P0 Element length 5 6 Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Seals A NBR V FPM W NBR Filtration rating Axx Mxx Pxx compatible with fluids HFA-HFB-HFC Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized ACCESSORIES Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Additional features page T Plug Low & Medium Pressure filters 8

LMP0- H - Recommended clearance space for maintenance H - Recommended clearance space for maintenance Filter length 5 6 LMP0 H [mm] 88 58 Connections G-G G-G-G5-G6 F-F F-F Dimensions H [mm] 660 690 R M / UNC M / UNC Filter length 5 6 LMP H [mm] 88 58 H [mm] 660 690 H - Recommended clearance space for maintenance Connections G-G G-G-G5-G6 F-F F-F R M / UNC M / UNC 9 Low & Medium Pressure filters

LMP00-0& 0- Order number for spare parts SPARE PARTS LMP 00-0 length - - c d e d f c a LMP 00-0 b LMP 0 - length 5-6 length 5-6 c d f e f d c b 5 a g a b a a b 6 5 c b d g g c d Item: Filter series LMP 00-0 length - - LMP 00-0 length 5-6 LMP 0 - lenght 5-6 Q.ty: pc. Q.ty: pc. Q.ty: pcs. Q.ty: pcs. Q.ty: pc. (a g) 5 6 Filter Seal Kit code number Indicator connection plug Housing spigot Tube element NBR FPM NBR FPM no bypass with bypass assembly See order 00509 00509 00509 00509 TH TV 0008 table 00509 00509 0008 000 Length 5: 0050 Length 6: 0050 Low & Medium Pressure filters 0

LMP00-0& 0- Low & Medium Pressure filters

Low & Medium Pressure filters

Low & Medium Pressure fi lters LMP 900-90 series Filter element according to DIN 550 Maximum pressure up to 0 bar - Flow rate up to 000 l/min Low & Medium Pressure filters

LMP900-90 GENERAL INFORMATION Technical data Low & Medium Pressure filters Maximum pressure up to 0 bar - Flow rate up to 000 l/min Filter element according to DIN 550 Filter housing materials - Head: Anodized Aluminium - Housing: Anodized Aluminium - Manifolds: Anodized Aluminium - Bypass valve: Steel Pressure - Working pressure: MPa (0 bar) - Test pressure:.5 MPa (5 bar) - Burst pressure: MPa (0 bar) - Pulse pressure fatigue test: 000 000 cycles with pressure from 0 to MPa (0 bar) Number of filter elements LMP 900-: filter element CU900 LMP 900-: filter elements CU900 Filter elements Filter element in according to with DIN 550 Size: 000 p element type - Microfibre filter elements - series N: 0 bar - Fluid flow through the filter element from OUT to IN. Seals - Standard NBR series A - Optional FPM series V Temperature From -5 C to +0 C Note LMP 900-90 filters are provided for vertical mounting Bypass valve - Opening pressure.5 bar ±0% - Other opening pressures on request. Connections LMP 900: In-line Inlet/Outlet LMP 90: 90 Inlet/Outlet Weights [kg] and volumes [dm ] LMP 900-90 Length Weights [kg] 9. 0. Length Volumes [dm ] 6 Hydraulic symbols LMP 0-00-900-950 execution S LMP 0-00-900-950 execution B Low & Medium Pressure filters

GENERAL INFORMATION The curves are plotted using mineral oil with density of 0.86 kg/dm in compliance with ISO 968. p varies proportionally with density. LMP900-90 Pressure drop 0.6 LMP 900/90 - F - 0.6 LMP 900/90 - F - Filter housings p pressure drop Δp bar 0. 0. LMP 900 F - LMP 90 F - Δp bar 0. 0. LMP 900 F - LMP 90 F - 0 00 00 600 900 00 500 Flow rate l/min 0 00 00 800 00 600 000 Flow rate l/min 9 LMP 900-90 Bypass valve pressure drop Δp bar 6 0 0 0 80 70 960 00 Flow rate l/min P EXECUTION LMP 900-90 filters are equipped with two 000 size cartridges in compliance with DIN 550 standard, connected by means of a removable coupling spigot. Coupling spigot 5 Low & Medium Pressure filters

LMP900-90 Designation & Ordering code COMPLETE FILTER Series and size LMP900 LMP90 Configuration example: LMP90 B A F A0 N P0 Length Bypass valve S Without bypass Seals and treatments A NBR V FPM Connections F SAE 000 psi/m F SAE 000 psi/unc F SAE 000 psi/m F SAE 000 psi/unc B.5 bar Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm A5 Inorganic microfiber 5 µm Element p N 0 bar Execution P0 MP Filtri standard P0 Maintenance from the bottom of the housing Pxx Customized Filter length Element series and size CU900 FILTER ELEMENT Configuration example: CU900 A0 A N P0 Length Nr. filter element Nr. filter elements Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm A5 Inorganic microfiber 5 µm Seals A NBR V FPM Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized ACCESSORIES Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Additional features page T Plug Low & Medium Pressure filters 6

LMP900-90 Connections F - F F - F LMP900 Length Dimensions R M6 5/8 UNC Recommended clearance space Recommended for maintenance clearance space for maintenance LMP900 Length H Execution [mm] P0 0 P0 800 Connections F - F F - F R M6 5/8 UNC H - Recommended clearance space for maintenance 7 Low & Medium Pressure filters

LMP900-90 Dimensions Connections F - F F - F LMP90 Length R M6 5/8 UNC 6 6 Recommended clearance space Recommended for maintenance clearance space for maintenance LMP90 Length H Execution [mm] P0 0 P0 800 Connections F - F F - F R M6 5/8 UNC 05 H - Recommended clearance space for maintenance Low & Medium Pressure filters 8

SPARE PARTS LMP900-90 Order number for spare parts LMP 900-90 LMP 900-90 length length c d c d d d e c e c a a b b a 6 a 5 g a 5 b g Item: (a g) 5 6 Filter Filter element Seal Kit code number Indicator connection plug Housing spigot Coupling spigot series Q.ty Q.ty NBR FPM Q.ty NBR FPM Q.ty Q.ty LMP 900-90 length pc. See pc. 00506 00506 pcs. pc. - order TH TV 000 00099 LMP 900-90 length pcs. table pc. 005065 005066 pcs. pc. pc. 9 Low & Medium Pressure filters

Low & Medium Pressure filters 50

Low & Medium Pressure fi lters LMP 90-90 series Filter element according to DIN 550 Maximum pressure up to 0 bar - Flow rate up to 000 l/min 5 Low & Medium Pressure filters

LMP90-90 GENERAL INFORMATION Technical data Low & Medium Pressure filters Maximum pressure up to 0 bar - Flow rate up to 000 l/min Filter element according to DIN 550 Filter housing materials - Head: Anodized Aluminium - Housing: Anodized Aluminium - Manifolds: Welded - Phosphated Steel - Bypass valve: Steel - Size 000 filter elements complying with DIN 550 standard Number of filter elements LMP 90: filter elements CU900 LMP 90: 6 filter elements CU900 Filter elements Filter element in according to with DIN 550 Size: 000 Seals - Standard NBR series A - Optional FPM series V Temperature From -5 C to +0 C Pressure - Working pressure:.5 MPa (5 bar) - Test pressure:.5 MPa (5 bar) p element type - Microfibre filter elements - series N: 0 bar - Fluid flow through the filter element from OUT to IN. Note LMP 90-90 filters are provided for vertical mounting Bypass valve - Opening pressure.5 bar ±0% - Other opening pressures on request. Connections LMP 90-90: In-line Inlet/Outlet Weights [kg] and volumes [dm ] LMP 90 LMP 90 Weights [kg] Length 89.6 9. Volumes [dm ] Length 58 87 Hydraulic symbols LMP 90-95 LMP 90-95 LMP 95 Manifolds Position of manifolds IN - OUT connections FA FB FC FD Low & Medium Pressure filters 5

GENERAL INFORMATION The curves are plotted using mineral oil with density of 0.86 kg/dm in compliance with ISO 968. p varies proportionally with density. LMP90-90 Pressure drop 0.6 LMP 90-90 Filter housings p pressure drop Δp bar 0. 0. LMP 90 LMP 90 0 00 600 00 800 00 000 Flow rate l/min 9 LMP 90-90 Bypass valve pressure drop Δp bar 6 0 0 0 80 70 960 00 Flow rate l/min Focus on: Indicator port Plug T - A/F 0 Bypass valve A/F 7 Oil drain plug G/ - A/F 0 5 Low & Medium Pressure filters

LMP90-90 Designation & Ordering code COMPLETE FILTER Series and size Configuration example: LMP90 B A FA A0 N P0 LMP90 LMP90 Length Bypass valve S Without bypass Seals and treatments A NBR V FPM B.5 bar Connections IN FA FB SAE 000 psi SAE 000 psi left left FC FD SAE 000 psi SAE 000 psi right right OUT left right left right Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm A5 Inorganic microfiber 5 µm Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized Element series and size CU900 FILTER ELEMENT Configuration example: CU900 A0 A N P0 Filter series and size LMP90 Nr. filter elements LMP90 Nr. 6 filter elements Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm A5 Inorganic microfiber 5 µm Seals A NBR V FPM Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized ACCESSORIES Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Additional features page T Plug Low & Medium Pressure filters 5

LMP90-90 LMP90 Dimensions 55 Low & Medium Pressure filters

LMP90-90 Dimensions LMP90 Low & Medium Pressure filters 56

SPARE PARTS LMP90-90 Order number for spare parts LMP 90-90 6d 6b 6c 6c 6 6b 6a 5 5a 5b 7 Item 7: for complete fi lter code and spare parts, see LMP 900-90 series chapter Quantity: - fi lter spare parts: LMP 90 - pcs. LMP 90 - pcs. - fi lter seal kit: LMP 90 - pcs. LMP 90 - pcs. Item: 5 (5a-5b) 6 (6a 6d) 7 Filter Manifold SAE 000 psi plugged flange Manifolds seal kit Threaded fasteners kit Filter series Q.ty IN OUT Q.ty Q.ty NBR FPM Q.ty Q.ty LMP 90 pc. 00970 0097 pcs. pc. 00500 005005 pc. 00905 pcs. 000 LMP90xxFxxxNP0 LMP 90 pc. 0097 0098 pcs. pc. 00500 005005 pc. 00905 pcs. 57 Low & Medium Pressure filters

Low & Medium Pressure filters 58

Low & Medium Pressure fi lters LMP 950-95 series Maximum pressure up to 0 bar - Flow rate up to 00 l/min 59 Low & Medium Pressure filters

LMP950-95 GENERAL INFORMATION Technical data Low & Medium Pressure filters Maximum pressure up to 0 bar - Flow rate up to 00 l/min Filter housing materials - Head: Anodized Aluminium - Housing: Anodized Aluminium - Bypass valve: Anodized Aluminium Seals - Standard NBR series A - Optional FPM series V Pressure - Working pressure: MPa (0 bar) - Test pressure:,5 MPa (5 bar) - Burst pressure: MPa (0 bar) - Pulse pressure fatigue test: 000 000 cycles with pressure from 0 to MPa (0 bar) Bypass valve - Opening pressure.5 bar ±0% - Other opening pressures on request. Temperature From -5 C to +0 C Connections LMP 950: In-line Inlet/Outlet LMP 95: 90 Inlet/Outlet Note LMP 950-95 filters are provided for vertical mounting p element type - Microfibre filter elements - series N: 0 bar - Fluid flow through the filter element from OUT to IN. Weights [kg] and volumes [dm ] Weights [kg] Volumes [dm ] Length Length LMP 950 5..5 5 8 Hydraulic symbols LMP 0-00-900-950 execution S LMP 0-00-900-950 execution B Low & Medium Pressure filters 60

GENERAL INFORMATION The curves are plotted using mineral oil with density of 0.86 kg/dm in compliance with ISO 968. p varies proportionally with density. LMP950-95 Pressure drop 0.6 LMP 950/95 - F - 0.6 LMP 950/95 - F - Filter housings p pressure drop Δp bar 0. 0. LMP 950 F - LMP 95 F - Δp bar 0. 0. LMP 950 F - LMP 95 F - 0 00 50 700 050 00 750 Flow rate l/min 0 00 500 000 500 000 500 Flow rate l/min 6 LMP 950-95 Bypass valve pressure drop Δp bar 0 0 00 800 00 600 000 Flow rate l/min P EXECUTION Execution P0 Internal tube for reduced flow rate recommended for flow rate values below 00/50 I/min. The use of option P0 makes it easier to fill the housing with the operating fluid. Internal tube for reduced flow rates 6 Low & Medium Pressure filters

LMP950-95 Designation & Ordering code COMPLETE FILTER Series and size Configuration example: LMP95 B A F A0 N P0 LMP950 LMP95 Length Bypass valve S Without bypass Seals and treatments A NBR V FPM Connections F SAE 000 psi/m F SAE 000 psi/unc F SAE 000 psi/m F SAE 000 psi/unc B.5 bar Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm A5 Inorganic microfiber 5 µm Element p N 0 bar P0 P0 Pxx Execution MP Filtri standard With internal reduced flow rate tube Customized Element series and size CU950 FILTER ELEMENT Configuration example: CU950 A0 A N P0 Element length Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm A5 Inorganic microfiber 5 µm Seals A V NBR FPM Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized ACCESSORIES Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Additional features page T Plug Low & Medium Pressure filters 6

LMP950-95 H - Recommended clearance space for maintenance H - Recommended clearance space for maintenance Filter length Connections F - F F - F LMP950 H [mm] 680 0 Dimensions H [mm] 50 900 R M6 5/8 UNC Filter length LMP95 H [mm] 680 0 H [mm] 50 900 H - Recommended clearance space for maintenance Connections F - F F - F R M6 5/8 UNC 6 Low & Medium Pressure filters

LMP950-95 SPARE PARTS Order number for spare parts LMP 950-95 g b 5 a a 6 a 7 b a c d f c d Item: Filter series LMP 950-95 length - Q.ty: pcs. Q.ty: pc. Q.ty: pcs. Q.ty: pc. Q.ty: pc. Q.ty: pc. (a g) 5 6 7 Filter Seal Kit code number Indicator connection plug Housing spigot Coupling Tube assembly element NBR FPM NBR FPM no bypass with bypass spigot length length See order table 005067 005068 TH TV 0006 00079 00099 0050 0050 Low & Medium Pressure filters 6

LMP950-95 65 Low & Medium Pressure filters

Low & Medium Pressure filters 66

Low & Medium Pressure fi lters LMP 95-95-95 series Maximum pressure up to 5 bar - Flow rate up to 000 l/min 67 Low & Medium Pressure filters

LMP95-95-95 GENERAL INFORMATION Technical data Low & Medium Pressure filters Maximum pressure up to 5 bar - Flow rate up to 000 l/min Filter housing materials - Head: Anodized Aluminium - Housing: Anodized Aluminium - Manifolds: Welded - Phosphated Steel - Bypass valve: Anodized Aluminium Number of filter elements - LMP 95: filter elements CU950- - LMP 95: filter elements CU950- - LMP 95: filter elements CU950- Seals - Standard NBR series A - Optional FPM series V Pressure - Working pressure:.5 MPa (5 bar) - Test pressure:.5 MPa (5 bar) Temperature From -5 C to +0 C Bypass valve - Opening pressure.5 bar ±0% - Other opening pressures on request. Connections LMP 95-95-95: In-line Inlet/Outlet p element type - Microfibre filter elements - series N: 0 bar - Fluid flow through the filter element from OUT to IN. Note LMP 95-95 - 95 filters are provided for vertical mounting Weights [kg] and volumes [dm ] LMP 95 LMP 95 LMP 95 Weights [kg] Length 96 8 9 Volumes [dm ] Length 66 99 Hydraulic symbols LMP 90-95 LMP 90-95 LMP 95 Manifolds FA Position of manifolds IN - OUT connections Low & Medium Pressure filters 68

GENERAL INFORMATION The curves are plotted using mineral oil with density of 0.86 kg/dm in compliance with ISO 968. p varies proportionally with density. LMP95-95-95 Pressure drop 0.6 LMP 95 0.6 LMP 95 Filter housings p pressure drop 0. 0. Δp bar 0. Δp bar 0. 0 0 600 00 800 00 000 Flow rate l/min 0 0 600 00 800 00 000 Flow rate l/min 0.6 LMP 95 0. Δp bar 0. 0 0 600 00 800 00 000 Flow rate l/min Δp bar 0.6 0. 0. LMP 95 A0 A06 A0 A6 A5 M5 Δp bar 0.6 0. 0. LMP 95 A0 A06 A0 A6 A5 M5 Pressure drop of filter complete with cartridge, oil viscosity 0 mm /s (cst) 0 0 600 00 800 00 000 Flow rate l/min 0 0 600 00 800 00 000 Flow rate l/min Δp bar 0.6 0. 0. LMP 95 A0 A06 A0 A6 A5 M5 0 0 600 00 800 00 000 Flow rate l/min 6 LMP 95-95 Bypass valve pressure drop Δp bar 0 0 00 800 00 600 000 69 Low & Medium Pressure filters

LMP95-95-95 GENERAL INFORMATION Options P EXECUTION Execution P0 Internal tube for reduced flow rate is recommended for flow rate values below: LMP 95-00 l/min LMP 95-50 l/min LMP 95-600 l/min The use of option P0 makes it easier to fill the housing with the operating fluid. Internal tube for reduced flow rates CMV & CUV FLANGE OPTION Flange with oil drain plug for rapid discharge Oil drain plug Code Thread Materials 7 6 5 CMV CUV G / SAE 0 - SAE flange - O-R 7 (FPM) for flange - Plug G -/ - O-R 68 for plug (FPM) 5 - No. Hex bolt screws UNI-EN 07 M6 x 65-0.9 6 - No. Spring washers UNI 75-B 6 7 - No. Nuts UNI 5587 - M6 - SAE flange - O-R 7 (FPM) for flange - Plug SAE 0 5/8 - UN - 7 O-R for plug (FPM) 5 - No. Hex bolt screws 5/8 UNC x / 6 - No. Spring washers UNI 75-B 6 7 - No. Nuts 5/8 UNC Low & Medium Pressure filters 70

GENERAL INFORMATION LMP95-95-95 Focus on: Breather plug G/ - A/F 0 Oil drain plug G/ - A/F 0 Indicator port Plug T - A/F 0 Indicator port - Plug T - A/F 0 Oil drain plug - G/ - A/F 0 7 Low & Medium Pressure filters

LMP95-95-95 Designation & Ordering code COMPLETE FILTER Series and size Configuration example: LMP95 B A FA A0 N P0 LMP95 LMP95 LMP95 Length Bypass valve S Without bypass Seals and treatments A NBR V FPM Connections FA SAE 000 psi B.5 bar Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm A5 Inorganic microfiber 5 µm Element p N 0 bar P0 P0 Pxx Execution MP Filtri standard With internal reduced flow rate tube Customized Element series and size CU950 FILTER ELEMENT Configuration example: CU950 A0 A N P0 Element length Filter series and size LMP95 Nr. filter elements LMP95 Nr. filter elements LMP95 Nr. filter elements Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm A5 Inorganic microfiber 5 µm Seals A V NBR FPM Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized ACCESSORIES Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Additional features page T Plug Low & Medium Pressure filters 7

LMP95-95-95 LMP95 Dimensions 7 Low & Medium Pressure filters

LMP95-95-95 Dimensions LMP95 Low & Medium Pressure filters 7

LMP95-95-95 LMP95 Dimensions 75 Low & Medium Pressure filters

LMP95-95-95 SPARE PARTS Order number for spare parts LMP 95-95 - 95 7 5 5b 5a 6d 6 6b 6c 6c 6b 6a Item 7: for complete fi lter code and spare parts, see LMP 950-95 series chapter Quantity: - fi lter spare parts: LMP 95 - pcs. LMP 95 - pcs. LMP 95 - pcs. - fi lter seal kit: LMP 95 - pcs. LMP 95 - pcs. LMP 95 - pcs. Item: 5 (5a-5b) 6 (6a 6d) 7 Filter Manifold SAE 000 psi plugged flange Manifolds seal kit Threaded fasteners kit Filter series Q.ty IN OUT Q.ty Q.ty NBR FPM Q.ty Q.ty LMP 95 pc. 00970 0097 pcs. pc. 00500 005005 pc. 00905 pcs. LMP 95 pc. 0097 0098 pcs. 000 pc. 00500 005005 pc. 00905 pcs. LMP95xxFxxxNP0x LMP 95 pcs. 00970 0097 pcs. pc. 005006 005007 pc. 00905 pcs. Low & Medium Pressure filters 76

LMP95-95-95 77 Low & Medium Pressure filters

Low & Medium Pressure filters 78

Low & Medium Pressure fi lters LMD series Maximum pressure up to 60 bar - Flow rate up to 0 l/min 79 Low & Medium Pressure filters

LMD GENERAL INFORMATION Technical data Low & Medium Pressure filters Maximum pressure up to 60 bar - Flow rate up to 0 l/min Filter housing materials - Head: Aluminium - Bowl: Cataphoretic Painted Steel - Bypass valve: AISI 0 - Nylon Seals - Standard NBR series A - Optional FPM series V Pressure - Working pressure: 6 MPa (60 bar) - Test pressure: 9 MPa (90 bar) - Burst pressure: MPa (0 bar) - Pulse pressure fatigue test: 000 000 cycles with pressure from 0 to 6 MPa (60 bar) Temperature From -5 C to +0 C Connections Inlet/Outlet In-Line Bypass valve - Opening pressure.5 bar ±0% - Other opening pressures on request. Note LMD 0 - filters are provided for vertical mounting p element type - Microfibre filter elements - series N: 0 bar - Fluid flow through the filter element from OUT to IN. Weights [kg] and volumes [dm ] Weights [kg] Volumes [dm ] Length Length LMD 9.5..8..6 5. Hydraulic symbols Style S Style B Low & Medium Pressure filters 80

GENERAL INFORMATION LMD The curves are plotted using mineral oil with density of 0.86 kg/dm in compliance with ISO 968. p varies proportionally with density. Pressure drop 0.9 LMD Δp Housing Filter housings p pressure drop Δp bar 0.6 0. 0 0 50 00 50 00 50 Flow rate l/min 9 LMD Bypass valve pressure drop Δp bar 6 0 0 00 00 00 00 500 Flow rate l/min 8 Low & Medium Pressure filters

LMD Designation & Ordering code Series and size LMD Length Bypass valve S Without bypass Seals and treatments A NBR V FPM W NBR compatible with fluids HFA-HFB-HFC B.5 bar Connections C G / F / NPT I SAE - 7/8 - UN L / SAE 000 psi/m + G / M / SAE 000 psi/unc + / NPT N / SAE 000 psi/unc + SAE 0-5/8 UN Connection for differential indicator 6 With plugged connection COMPLETE FILTER Configuration example: Filtration rating Axx Mxx Pxx LMD B A C 6 A0 N P0 Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized Element series and size CU0 FILTER ELEMENT Configuration example: CU0 A0 A N P0 Element length Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Seals A NBR V FPM W NBR Filtration rating Axx Mxx Pxx compatible with fluids HFA-HFB-HFC Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized ACCESSORIES Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Additional features page T Plug Low & Medium Pressure filters 8

LMD Filter length LMD Dimensions H [mm] 80 50 68 Connections C F - I L M - N R M0 /8 UNC M0 /8 UNC Recommended clearance space for maintenance 8 Low & Medium Pressure filters

LMD Order number for spare parts SPARE PARTS LMD c d e f g h a b Item: Filter series LDD Q.ty: pc. Q.ty: pc. Q.ty: pcs. (a h) Filter Seal Kit code number Indicator connection plug element NBR FPM NBR FPM See order table 005067 005067 TH TV Low & Medium Pressure filters 8

LMD 85 Low & Medium Pressure filters

Low & Medium Pressure filters 86

Low & Medium Pressure fi lters LMD 00-0 & series Maximum pressure up to 6 bar - Flow rate up to 590 l/min 87 Low & Medium Pressure filters

LMD00-0 & Technical data GENERAL INFORMATION Low & Medium Pressure filters Maximum pressure up to 6 bar - Flow rate up to 590 l/min Filter housing materials - Head: Anodized Aluminium - Housing: Anodized Aluminium - Manifolds: Steel - Painted black - Bypass valve: Steel - -way ball valve: Steel housings - Stainless Steel ball - Valve: Phosphated Steel - Stainless Steel Pressure - Working pressure:.6 MPa (6 bar) - Test pressure:.5 MPa (5 bar) Bypass valve - Opening pressure.5 bar ±0% - Other opening pressures on request. p element type - Microfibre filter elements - series N - W: 0 bar - Fluid flow through the filter element from OUT to IN. Seals FPM series V Temperature From -5 C to +0 C Connections - LMD 00-0: In-line Inlet/Outlet - LMD 0: Same side - LMD 00-0-: In-Line Note LMP 00-0 - filters are provided for vertical mounting Weights [kg] and volumes [dm ] LMD 00-0 LMD Length 60 - Weights [kg] 5 65 68 6 7 78 Length 0 - Volumes [dm ] 5 8 8 6 Hydraulic symbols LMD 00-0--95 P EXECUTION Execution P0 Internal tube for reduced flow rate is recommended for flow rate values below 50 I/min. The use of option P0 makes it easier to fill the housing with the operating fluid. Internal tube for reduced flow rates Low & Medium Pressure filters 88

GENERAL INFORMATION LMD00-0 & The curves are plotted using mineral oil with density of 0.86 kg/dm in compliance with ISO 968. p varies proportionally with density. Pressure drop 0.6 LMD 00-0 - Filter housings p pressure drop Δp bar 0. 0. 0 00 00 00 00 500 600 Flow rate l/min 9 LMD 00-0 - Bypass valve pressure drop Δp bar 6 0 0 0 80 0 560 700 Flow rate l/min Focus on A Breather plug G/8 - A/F 8 B Indicator port Plug T - A/F 0 C Compensation valve D Oil drain plug G/8 - A/F 8 LMP 00-0 - Fit one differential indicator for individual filter assembly. A B A B D C A C B B D D 89 Low & Medium Pressure filters

LMD00-0 Designation & Ordering code Series and size LMD00 LMD0 Length 5 6 Bypass valve S Without bypass B.5 bar Seals and treatments V FPM Z FPM compatible with fluids HFA-HFB-HFC COMPLETE FILTER Configuration example: LMD0 Filtration rating Axx Mxx Pxx B V F A0 N P0 Connections F / SAE 000 psi/m F / SAE 000 psi/unc F / SAE 000 psi/m, In-line connections F / SAE 000 psi/unc, In-line connections LMD00 LMD0 Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Element p N 0 bar Execution P0 MP Filtri standard P0 Maintenance from the bottom of the housing Pxx Customized Filter length 5 6 Element series and size CU00 FILTER ELEMENT Configuration example: CU00 A0 V N P0 Element length 5 6 Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Seals V Z FPM FPM compatible with fluids HFA-HFB-HFC Filtration rating Axx Mxx Pxx Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized ACCESSORIES Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Additional features page T Plug Low & Medium Pressure filters 90

LMD00-0 Dimensions LMD00 Length Connections F F F F R M / UNC M / UNC Recommended clearance space for maintenance 9 Low & Medium Pressure filters

LMD00-0 Dimensions LMD00 Length 5-6 H [mm] Filter H Execution length [mm] P0 P0 5 88 0 660 6 0 690 Connections F F F F R M / UNC M / UNC H - Recommended clearance space for maintenance Low & Medium Pressure filters 9

LMD00-0 Dimensions LMD0 Length Connections F F F F R M / UNC M / UNC Recommended clearance space for maintenance 9 Low & Medium Pressure filters

LMD00-0 Dimensions LMD0 Length 5-6 H [mm] Filter H Execution length [mm] P0 P0 5 0 0 660 6 7 0 690 Connections F F F F R M / UNC M / UNC H - Recommended clearance space for maintenance Low & Medium Pressure filters 9

LMD00-0 95 Low & Medium Pressure filters

LMD Designation & Ordering code Series and size LMD Length 5 6 Bypass valve S Without bypass B.5 bar Seals and treatments V Z FPM FPM compatible with fluids HFA-HFB-HFC Connections F / SAE 000 psi/m F / SAE 000 psi/unc F / SAE 000 psi/m, In-line connections F / SAE 000 psi/unc, In-line connections COMPLETE FILTER Configuration example: LMD Filtration rating Axx Mxx Pxx 5 B V F A0 N P0 Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Element p N 0 bar Execution P0 MP Filtri standard P0 With internal reduced flow rate tube Pxx Customized Element series and size CU00 FILTER ELEMENT Configuration example: CU00 5 A0 V N P0 Element length 5 6 Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Seals V Z FPM FPM compatible with fluids HFA-HFB-HFC Filtration rating Axx Mxx Pxx Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized ACCESSORIES Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Additional features page T Plug Low & Medium Pressure filters 96

LMD Filter length 5 6 LMD H [mm] 6 9 Dimensions H [mm] 660 690 97 Low & Medium Pressure filters

LMD00-0 & Order number for spare parts SPARE PARTS LMD 00 5c 5d a 7 b 5b 5a 6 LMD 0 LMD b 5b 5a a 6 a 7 5d 5c 6 7 b 5c 5d 5b 5a Item: Filter series LMD 00-0 - Q.ty: pc. Q.ty: pcs. Q.ty: pc. Q.ty: pc. Q.ty: pc. Q.ty: pcs. (a b) 5 (5a 5d) 6 7 -way ball valve PN 6 One-way valve Seal Kit Threaded Kit ball valve Filter / SAE 000 psi/m / SAE 000 psi/unc fasteners kit with hose fitting See order table 0000 000 0009 005099 00906 0050 LMP00xF... Low & Medium Pressure filters 98

LMD00-0 & 99 Low & Medium Pressure filters

Low & Medium Pressure filters 00

Low & Medium Pressure fi lters LMD 95 series Maximum pressure up to 6 bar - Flow rate up to 00 l/min 0 Low & Medium Pressure filters

LMD95 GENERAL INFORMATION Technical data Low & Medium Pressure filters Maximum pressure up to 6-5 bar - Flow rate up to 00 l/min Filter housing materials - Head: Anodized Aluminium - Housing: Anodized Aluminium - Manifolds: Welded - Painted black - Bypass valve: Steel - -way ball valve: Steel body - Stainless Steel ball - Check valve: Cast Iron body - AISI 0 leaf Pressure - SAE + DIN Flange - Working pressure:.6 MPa (6 bar) - Test pressure:.5 MPa (5 bar) Seals FPM series V Temperature From -5 C to +0 C Connections - LMD 95: In-line Inlet/Outlet - Same side Bypass valve - Opening pressure.5 bar ±0% - Other opening pressures on request. Note LMD 95 filters are provided for vertical mounting Number of filter elements LMD 95: filter elements CU950- p element type - Microfibre filter elements - series N: 0 bar - Fluid flow through the filter element from OUT to IN. Weights [kg] and volumes [dm ] LMD 95 Weights [kg] DN 80 DN 00 0 0 Volumes [dm ] DN 80 DN 00 6 66 Hydraulic symbols LMD 00-0--95 Low & Medium Pressure filters 0

GENERAL INFORMATION LMD95 The curves are plotted using mineral oil with density of 0.86 kg/dm in compliance with ISO 968. p varies proportionally with density. Pressure drop. LMD 95 Filter housings p pressure drop Δp bar 0.8 0. DN 80 DN 00 0 0 0 80 70 960 00 Flow rate l/min 6 LMD 95 Bypass valve pressure drop Δp bar 0 0 00 800 00 600 000 Flow rate l/min Focus on P EXECUTION Execution P0 Internal tube for reduced flow rate is recommended for flow rates lower than 50 I/min. C The use of option P0 makes it easier to fill the housing with the operating fluid. D B B Internal tube for reduced flow rates LMD 95 Fit one differential indicator for individual filter assembly. A B C D Breather plug G/ - A/F 0 Indicator port Plug T - A/F 0 Compensation valve Oil drain plug G/ - A/F 0 0 Low & Medium Pressure filters

LMD95 Designation & Ordering code COMPLETE FILTER Series and size Configuration example: LMD95 B V F A0 N P0 LMD95 Length Bypass valve S Without bypass Seals and treatments V FPM B.5 bar Connections F SAE 000 psi/m F SAE 000 psi/unc F SAE 000 psi/m F SAE 000 psi/unc F5 SAE 000 psi/m, In-line connections F6 SAE 000 psi/unc, In-line connections F7 SAE 000 psi/m, In-line connections F8 SAE 000 psi/unc, In-line connections Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm A5 Inorganic microfiber 5 µm P0 P5 Resin impregnated paper 0 µm Resin impregnated paper 5 µm Element p N 0 bar P0 P0 Pxx Execution MP Filtri standard With internal reduced flow rate tube Customized Element series and size CU950 FILTER ELEMENT Configuration example: CU950 A0 V N P0 Element length Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm A5 Inorganic microfiber 5 µm P0 P5 Resin impregnated paper 0 µm Resin impregnated paper 5 µm Seals V FPM Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized ACCESSORIES Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Additional features page T Plug Low & Medium Pressure filters 0

LMD95 Dimensions Recommended clearance space for maintenance LMD95 Connections F F F F F5 F6 F7 F8 H [mm] 50 50 577 577 50 50 577 577 L [mm] 88 88 9 9 88 88 9 9 L [mm] 588 588 68 68 588 588 68 68 M [mm] 70 70 650 650 70 70 650 650 05 Low & Medium Pressure filters

LMD95 Order number for spare parts SPARE PARTS LMD 95 6 7 5e 5f a b 5b 5a 5c 5f 5d a a Item: Filter series LMD 95 F - F - F5 - F6 / D - D ( SAE / DIN PN6 DN 80) F - F - F7 - F8 / D - D ( SAE / DIN PN6 DN 00) Q.ty: pc. Q.ty: pc. Q.ty: pcs. 5 6 7 Q.ty: pcs. One-way valve -way ball valve PN 6 SAE 000 psi/m SAE 000 psi/m SAE 000 psi/unc SAE 000 psi/unc 0005 0006 0008 0009 0008 0009 005089 Q.ty: pc. Q.ty: pc. (5a 5f) Seal Kit Threaded fasteners kit 005088 009056 009057 G / Ball Valve Kit with straight fittings 0050 Item 7: for complete fi lter code and spare parts, see LMP 950-95 series chapter Quantity: - fi lter spare parts: pcs. - fi lter seal kit: pcs. Filter LMP95xVFxxxNP0 LMP95xVFxxxNP0 Low & Medium Pressure filters 06

LMD95 07 Low & Medium Pressure filters

Low & Medium Pressure filters 08

Low & Medium Pressure filters LDP & LDD series Maximum pressure up to 60 bar - Flow rate up to 0 l/min DIN 550 Filter element according to DIN 550 09 Low & Medium Pressure filters

LDP & LDD GENERAL INFORMATION Filter element according to DIN 550 Technical data Low & Medium Pressure filters Filter housing materials - Head: Aluminium - Bowl: Cataphoretic Painted Steel - Bypass valve: AISI 0 - Nylon Maximum pressure up to 60 bar - Flow rate up to 0 l/min Seals - Standard NBR series A - Optional FPM series V Pressure - Working pressure: 6 MPa (60 bar) - Test pressure: 9 MPa (90 bar) - Burst pressure: MPa (0 bar) - Pulse pressure fatigue test: 000 000 cycles with pressure from 0 to 6 MPa (60 bar) Temperature From -5 C to +0 C Connections Inlet/Outlet In-Line Bypass valve - Opening pressure.5 bar ±0% - Other opening pressures on request. Note LDP - LDD filters are provided for vertical mounting p element type - Microfibre filter elements - series N: 0 bar - Fluid flow through the filter element from OUT to IN. Weights [kg] and volumes [dm ] LDP - LDD 06 LDP - LDD 05 LDP - LDD 00 Weights [kg] Length 9. 9.5. Volumes [dm ] Length.6..8 Hydraulic symbols LDP execution S LDP execution B LDD execution S LDD execution B Low & Medium Pressure filters 0

GENERAL INFORMATION LDP & LDD Filter element according to DIN 550 The curves are plotted using mineral oil with density of 0.86 kg/dm in compliance with ISO 968. p varies proportionally with density. 0.9 LDP - Δp Housing 0.9 LDD - Δp Housing Pressure drop Filter housings p pressure drop 0.6 / / 0.6 Δp bar 0. Δp bar 0. 0 0 80 60 0 0 00 Flow rate l/min 0 0 50 00 50 00 50 Flow rate l/min 9 LDD - LDP Bypass valve pressure drop Δp bar 6 0 0 00 00 00 00 500 Flow rate l/min Low & Medium Pressure filters

LDP Designation & Ordering code Filter element according to DIN 550 Series and size LDP Size 06 Element according to DIN 550 - T DN60 05 Element according to DIN 550 - T DN50 00 Element according to DIN 550 - T DN00 Bypass valve S Without bypass B.5 bar Seals and treatments A NBR V FPM W NBR compatible with fluids HFA-HFB-HFC COMPLETE FILTER Configuration example: Filtration rating Axx Mxx Pxx LDP 05 B A D 6 A0 N P0 Connections A G B G / C G / D NPT E / NPT Connection for differential indicator 6 With plugged connection F G H I / NPT SAE 6-5/6 - UN SAE 0-5/8 - UN SAE - 7/8 - UN Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized Element series and size DN FILTER ELEMENT Configuration example: DN 05 A0 A N P0 Element size 06 Element according to DIN 550 - T DN60 05 Element according to DIN 550 - T DN50 00 Element according to DIN 550 - T DN00 Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Seals A NBR V FPM W NBR Filtration rating Axx Mxx Pxx compatible with fluids HFA-HFB-HFC Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized ACCESSORIES Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Additional features page T Plug Low & Medium Pressure filters

Filter element according to DIN 550 Filter size 06 05 00 LDP LDP Dimensions H [mm] 68 58 508 Connections A-B-C D-E-F-G-H-I R M8 5/6 UNC Drain plug only length Recommended clearance space for maintenance Low & Medium Pressure filters

LDD Designation & Ordering code Filter element according to DIN 550 Series and size LDD Size 06 Element according to DIN 550 - T DN60 05 Element according to DIN 550 - T DN50 00 Element according to DIN 550 - T DN00 Bypass valve S Without bypass Seals and treatments A NBR V FPM W NBR compatible with fluids HFA-HFB-HFC B.5 bar Connections C G / F / NPT I SAE - 7/8 - UN L / SAE 000 psi/m + G / M / SAE 000 psi/unc + / NPT N / SAE 000 psi/unc + SAE 0-5/8 UN Connection for differential indicator 6 With plugged connection COMPLETE FILTER Configuration example: Filtration rating Axx Mxx Pxx LDD 05 B A C 6 A0 N P0 Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized Element series and size DN FILTER ELEMENT Configuration example: DN 05 A0 A N P0 Element size 06 Element according to DIN 550 - T DN60 05 Element according to DIN 550 - T DN50 00 Element according to DIN 550 - T DN00 Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Seals A NBR V FPM W NBR Filtration rating Axx Mxx Pxx compatible with fluids HFA-HFB-HFC Element p N 0 bar ACCESSORIES Execution P0 MP Filtri standard Pxx Customized Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Additional features page T Plug Low & Medium Pressure filters

Filter element according to DIN 550 Filter size 06 05 00 LDD LDD Dimensions H [mm] 90 80 50 Connections C F - I L M - N R M0 /8 UNC M0 /8 UNC Recommended clearance space for maintenance 5 Low & Medium Pressure filters

LDP & LDD Filter element according to DIN 550 SPARE PARTS Order number for spare parts LDP c d a b Item: Filter series LDP Q.ty: pc. Q.ty: pc. Q.ty: pc. (a d) Filter Seal Kit code number Indicator connection plug element NBR FPM NBR FPM See order table 00505 00506 TH TV Low & Medium Pressure filters 6

SPARE PARTS LDP & LDD Filter element according to DIN 550 LDD Order number for spare parts c d e f g h a b Item: Filter series LDD Q.ty: pc. Q.ty: pc. Q.ty: pc. (a h) Filter Seal Kit code number Indicator connection plug element NBR FPM NBR FPM See order table 005067 005067 TH TV 7 Low & Medium Pressure filters

Low & Medium pressure filters Clogging indicators Differential indicators Introduction Filter elements are efficient only if their Dirt Holding Capacity is fully exploited. This is achieved by using filter housings equipped with clogging indicators. These devices trip when the clogging of the filter element causes an increase in pressure drop across the filter element. The indicator is set to alarm before the element becomes fully clogged. MP Filtri can supply differential pressure indicators with a visual, electrical or both signals. Suitable indicator types DIFFERENTIAL INDICATORS Differential indicators are used on the Pressure line to check the efficency of the filter element. They measure the pressure upstream and downstream of the filter element (differential pressure). Standard items are produced with special connection G / size. Also available in Stainless Steel models. OUT OUT OUT OUT IN IN IN IN Quick reference guide Filter series Visual indicator Electrical indicator Electrical / Visual indicator Electronic indicator With bypass valve LMP 0 - - 6-8 - 9 LMP 0 - - LMP 0 - - LDP LMP 00-0 - 0 - LMP 90-90 - 95-95 - 95 LMD - 00-0 - - 95 - LDD DVA0xP0 DVM0xP0 DEA0xA50P0 DEM0xAxxP0 DLA0xA5P0 DLA0xA5P0 DLA0xA7P0 DLE0xA50P0 DLE0xF50P0 DTA0xF70P0 Without bypass valve LMP 0 - - 6-8 - 9 LMP 0 - - LMP 0 - - LDP LMP 00-0 - 0 - LMP 90-90 - 95-95 - 95 LMD - 00-0 - - 95 - LDD DVA50xP0 DVM50xP0 DEA50xA50P0 DEM50xAxxP0 DLA50xA5P0 DLA50xA5P0 DLA50xA7P0 DLE50xA50P0 DLE50xF50P0 DTA50xF70P0 Low & Medium Pressure filters 8

Electrical Differential Indicator Settings bar ±0% 5 bar ±0% 5 DEA*50 Ordering code DE A 0 x A 50 P0 DE A 50 x A 50 P0 A/F 0 Max tightening torque: 65 N m Hydraulic symbol Electrical symbol 5 DIFFERENTIAL INDICATORS Materials - Body: Brass - Base: Black Nylon - Contacts: Silver - Seal: HNBR - FPM Dimensions Technical data - Max working pressure: 0 bar - Proof pressure: 60 bar - Burst pressure: 60 bar - Working temperature: From -5 C to +0 C - Compatibility with fluids: Mineral oil, Synthetic fluids HFA, HFB, HFC according to ISO 9 - Degree protection: IP66 according to EN 6059 IP69K according to ISO 065 50 Electrical data - Electrical connection: EN 750-80 - Resistive load: 0. A / 5 Vdc 60 75 Electrical Differential Indicator Settings bar ±0% 5 bar ±0% DEM*0 A/F 8 Max tightening torque: 65 N m Ordering code DE M 0 x x 0 P0 DE M 50 x x 0 P0 flexible cable: 90 to A 60 Hydraulic symbol Electrical symbol GREEN LAMP RED LAMP Materials - Body: Brass - Base: Black Nylon - Contacts: Silver - Seal: HNBR - FPM Technical data - Max working pressure: 0 bar - Proof pressure: 60 bar - Burst pressure: 60 bar - Working temperature: From -5 C to +0 C 5 Thermal lockout Thermal lockout Thermal GREEN LAMP - Compatibility with fluids: Mineral oil, Synthetic fluids HFA, HFB, HFC according to ISO 9 - Degree protection: IP66 according to EN 6059 Electrical data - Electrical connection: AMP Superseal series.5 - Resistive load: 0. A / 5 Vdc - Switching type: Normally open contacts (NC on request) - Thermal lockout: Normally open up to 0 C (option F ) 75 RED LAMP Electrical Differential Indicator Settings bar ±0% 5 bar ±0% 60 DEM*0 Ordering code DE M 0 x x 0 P0 DE M 50 x x 0 P0 75 Hydraulic symbol Electrical symbol Materials - Body: Brass - Base: Black Nylon - Contacts: Silver - Seal: HNBR - FPM Technical data - Max working pressure: 0 bar - Proof pressure: 60 bar C - Burst pressure: 60 bar - Working temperature: From -5 C to +0 C - Compatibility with fluids: Mineral oil, Synthetic fluids A HFA, HFB, HFC according to ISO 9B - Degree protection: IP66 according to EN 6059 Thermal lockout Thermal lockout Thermal lockout Thermal lockout A/F 8 Max tightening torque: 65 N m Electrical data - Electrical connection: AMP Time junior - Resistive load: 0. A / 5 Vdc - Switching type: Normally open contacts (NC on request) - Thermal lockout: Normally open up to 0 C (option F ) C Thermal lockout 9 Low & Medium Pressure filters

DIFFERENTIAL INDICATORS Dimensions 60 Electrical Differential Indicator Settings bar ±0% 5 bar ±0% 75 DEM*0 Thermal lockout Ordering code DE M 0 x x 0 P0 DE M 50 x x 0 P0 A/F 8 Max tightening torque: 65 N m 75 Hydraulic symbol Electrical symbol Thermal lockout Materials - Body: Brass - Base: Black Nylon - Contacts: Silver - Seal: HNBR - FPM Technical data - Max working pressure: 0 bar - Proof pressure: 60 bar - Burst pressure: 60 bar - Working temperature: C From -5 C to +0 C - Compatibility Thermal with fluids: lockoutmineral oil, Synthetic fluids A HFA, HFB, HFC according to ISO 9 - Degree protection: IP66 according to EN 6059 B Electrical data - Electrical connection: Deutsch DT-0--P - Resistive load: 0. A / 5 Vdc - Switching type: Normally open contacts (NC on request) - Thermal lockout: Normally open up to 0 C (option F ) 5 75 Electrical Differential Indicator Settings bar ±0% 5 bar ±0% A/F 8 Max tightening torque: 65 N m DEM*5 Thermal lockout Ordering code DE M 0 x x 5 P0 DE M 50 x x 5 P0 flexible cable: 0 to A 5 Hydraulic symbol Electrical symbol C Thermal lockout A B Materials - Body: Brass - Base: Black Nylon - Contacts: Silver - Seal: HNBR - FPM Technical data - Max working pressure: 0 bar - Proof pressure: 60 bar - Burst pressure: 60 bar - Working temperature: From -5 C to +0 C - Compatibility with fluids: Mineral oil, Synthetic fluids HFA, HFB, HFC according to ISO 9 - Degree protection: IP66 according to EN 6059 Electrical data - Electrical connection: Deutsch DT-0--P - Resistive load: 0. A / 5 Vdc - Switching type: SPDT contact - Thermal lockout: Normally open up to 0 C (option F ) 50 Electrical/Visual Differential Indicator Settings bar ±0% 5 bar ±0% 5 DLA*5 - DLA*5 Ordering code DL A 0 x A x x P0 DL A 50 x A x x P0 A/F 0 Max tightening torque: 65 N m Hydraulic symbol Electrical symbol GREEN LAMP RED LAMP Materials - Body: Brass - Base: Transparent Nylon - Contacts: Silver - Seal: HNBR - FPM Technical data - Max working pressure: 0 bar - Proof pressure: 60 bar - Burst pressure: 60 bar - Working temperature: From GREEN-5 C to RED +0 C LAMP LAMP - Compatibility with fluids: Mineral oil, Synthetic fluids HFA, HFB, HFC according to ISO 9 - Degree protection: IP66 according to EN 6059 IP69K according to ISO 065 5 Electrical data - Electrical connection: EN 750-80 - Type 5 5 5 - Lamps Vdc 0 Vdc - Resistive load: 0.8 A / Vdc 0. A / 0 Vdc Low & Medium Pressure filters 0

Electrical/Visual Differential Indicator 50 Settings bar ±0% 5 bar ±0% DLA*7 Ordering code DL A 0 x A 7 P0 DL A 50 x A 7 P0 A/F 0 Max tightening torque: 65 N m Hydraulic symbol Electrical symbol 5 GREEN LAMP RED LAMP DIFFERENTIAL INDICATORS Materials - Body: Brass - Base: Black Nylon - Contacts: Silver - Seal: HNBR - FPM Dimensions Technical data - Max working pressure: 0 bar - Proof pressure: 60 bar - Burst pressure: 60 bar - Working temperature: From -5 C to +0 C - Compatibility with fluids: Mineral oil, Synthetic fluids HFA, HFB, HFC according to ISO 9 - Degree protection: IP65 according to EN 6059 IP69K according to ISO 065 Electrical data - Electrical connection: IEC 6076--0 D (M) - Lamps Vdc - Resistive load: 0. A / Vdc Electrical/Visual Differential Indicator 58 Settings bar ±0% 5 bar ±0% 5 GREEN LAMP DLE*A50 RED LAMP Ordering code DL E 0 x A 50 P0 DL E 50 x A 50 P0 59 Hydraulic symbol Electrical symbol 58 Materials - Body: Brass - Base: Black Nylon - Contacts: Silver - Seal: HNBR - FPM Technical data - Max working pressure: 0 bar - Proof pressure: 58 60 bar - Burst pressure: 60 bar - Working temperature: From -5 C to +0 C - Compatibility with fluids: Mineral oil, Synthetic fluids HFA, HFB, HFC according to ISO 9 - Degree protection: IP65 according to EN 6059 A/F Max tightening torque: 95 N m Electrical data - Electrical connections: EN 750-80 - Resistive load: 5 A / 50 Vac - Available the connector with lamps 58 Electrical/Visual Differential Indicator Settings bar ±0% 5bar ±0% DLE*F50 Ordering code DL E 0 x F 50 P0 DL E 50 x F 50 P0 58 Hydraulic symbol Electrical symbol Materials - Body: Brass - Thermal Base: lockout Black Nylon - Contacts: Silver - Seal: HNBR - FPM Technical data - Max working pressure: 0 bar - Proof pressure: 60 bar - Burst pressure: 60 bar - Working temperature: From -5 C to +0 C - Compatibility with fluids: Mineral oil, Synthetic fluids HFA, HFB, HFC according to ISO 9 - Degree protection: IP65 according to EN 6059 A/F Max tightening torque: 95 N m Thermal lockout Electrical data - Electrical connections: EN 750-80 - Resistive load: 5 A / 50 Vac - Thermal lockout setting: +0 C Low & Medium Pressure filters

DIFFERENTIAL INDICATORS Dimensions Electronic Differential Indicator Settings bar ±0% 5 bar ±0% 7 DTA*70 Ordering code DT A 0 x x 70 P0 DT A 50 x x 70 P0 A/F 0 Max tightening torque: 50 N m 5 Hydraulic symbol 5 Electrical symbol + Vdc 0 ma 75% - N.O. Digital output 00% - N.O. Digital output 0 Vdc Materials - Body: Brass - Internal parts: Brass - Nylon - Contacts: Silver - Seal: HNBR - FPM Technical data - Max working pressure: 0 bar - Proof pressure: 60 bar - Burst pressure: 60 bar - Compatibility with fluids: Mineral oil, Synthetic fluids HFA, HFB, HFC according to ISO 9 - Degree protection: IP67 according to EN 6059 Electrical data - Electrical connection: IEC 6076--0 D (M) - Power supply: Vdc - Analogue output: From to 0 ma - Thermal lockout: 0 C (all output signals stalled up to 0 C) Visual Differential Indicator Settings bar ±0% 5 bar ±0% 9 DVA Ordering code DV A 0 x P0 DV A 50 x P0 Green / Red clogging indicator A/F 8 Max tightening torque: 65 N m Hydraulic symbol Materials - Body: Brass - Internal parts: Brass - Nylon - Contacts: Silver - Seal: HNBR - FPM Technical data - Reset: Automatic reset - Max working pressure: 0 bar - Proof pressure: 60 bar - Burst pressure: 60 bar - Working temperature: From -5 C to +0 C - Compatibility with fluids: Mineral oil, Synthetic fluids HFA, HFB, HFC according to ISO 9 - Degree protection: IP65 according to EN 6059 Visual Differential Indicator Settings bar ±0% 5 bar ±0% DVM Ordering code DV M 0 x P0 DV M 50 x P0 Red clogging indicator Hydraulic symbol Materials - Body: Brass - Internal parts: Brass - Nylon - Contacts: Silver - Seal: HNBR - FPM Technical data - Reset: Manual reset - Max working pressure: 0 bar - Proof pressure: 60 bar - Burst pressure: 60 bar - Working temperature: From -5 C to +0 C - Compatibility with fluids: Mineral oil, Synthetic fluids HFA, HFB, HFC according to ISO 9 - Degree protection: IP65 according to EN 6059 A/F 0 Max tightening torque: 65 N m Low & Medium Pressure filters

Seal HNBR FPM T Indicator plug Ordering code T H T V DIFFERENTIAL INDICATORS Materials - Body: Phosphatized steel - Seal: HNBR / FPM Dimensions A/F 0 Max tightening torque: 50 N m DESIGNATION & ORDERING CODE - DIFFERENTIAL INDICATORS Series Configuration example : DE M 0 H F 50 P0 DE Electrical differential indicator Configuration example : DL E 50 V A 7 P0 DL Electrical/Visual differential indicator Configuration example : DT A 0 H F 70 P0 DT Electronic differential indicator DV Visual differential indicator Configuration example : DV M 50 V P0 Type A Standard type M With wired electrical connection E For high power supply DE DL DT A M DV With automatic reset With manual reset Pressure setting 0 bar 50 5 bar Seals H HNBR V FPM Thermostat A F Without With thermostat DEA DEM DLA DLE DT DV Electrical connections 0 Connection AMP Superseal series.5 0 Connection AMP Timer Junior 0 Connection Deutsch DT-0--P 5 Connection Deutsch DT-0--P 50 Connection EN 750-80 5 Connection EN 750-80, transparent base with lamps Vdc 5 Connection EN 750-80, transparent base with lamps 0 Vdc 70 Connection IEC 6076--0 D (M) 7 Connection IEC 6076--0 D (M), black base with lamps Vdc DEA DEM DLA DLE DT DV Option P0 MP Filtri standard Pxx Customized Series T Indicator plug DESIGNATION & ORDERING CODE - DIFFERENTIAL INDICATOR PLUG Configuration example T H Seals H HNBR V FPM Low & Medium Pressure filters

Filter elements are efficient only if their Dirt Holding Capacity is fully exploited. This is achieved by using filter housings equipped with clogging indicators. These devices trip when the clogging of the filter element causes an increase in pressure drop across the filter element. The indicator is set to alarm before the element becomes fully clogged. MP Filtri can supply indicators of the following designs: - Vacuum switches and gauges - Pressure switches and gauges - Differential pressure indicators These type of devices can be provided with a visual, electrical or both signals. Clogging Indicators 580

Clogging Indicators 58 Clogging Indicators

Clogging Indicators 58

Clogging indicators Clogging indicators 58 Clogging Indicators