201A-9 INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 01/2010

Similar documents
BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

MODEL 235P INSTALLATION INSTRUCTIONS. Revision B1 Rapid City, SD, USA, 08/2009 II_235P_B1

MODEL 233P/111P/233P-1.5

INSTALLATION INSTRUCTIONS FOR SYMCOM MODEL 231-P-INSIDER

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

Surface mounting, flush mounting, and DIN track mounting

DEVICE STATE/BYPASSED FAILURE OVERLOAD

RVS-DN Digital Reduced Voltage Motor Starter

Industrial Power Supplies

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets

Single & Three-Phase Soft Starters

RVS-DX Digital Reduced Voltage Motor Starter

Model Number Structure

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Part # Features & Applications Specifications Cross Reference

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

Three-Phase Soft Starters

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Solid State Relays contactor with Integrated Fuse Type RGC1F

XM1 - Motor protection relay

SOLITRON MIDI - With Integrated Heatsink Types RJ1A, RJ1B

PRODUCT SPECIFICATION OUTPUT CURRENT (A) OUTPUT CURRENT TOLERANCE ±7% ±7% ±10% ±10% ±7% 1.8. Units % % % Typ. Typ.

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

The Complete System Solution! Highest Grade Electronic Components RoHS Compliant.

P445 Series Electronic Lube Oil Control

Application Engineering

SECTION MOTOR CONTROL

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

2 pole, 10 A AC/DC supply non polarized Plug-in for use with 94 series sockets

Uninterruptible Power Supplies

Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

EMC and Durability Lab, HCL Technologies Ltd., #73-74, South Phase, Ambattur Industrial Estate, Chennai

Liebert GXT VA RT230 Rack-Tower model GUIDE SPECIFICATIONS 1.0 GENERAL

FAMILY. 1-Phase 1 Up to 25A Up to 40A Up to 80A Up to 600VAC 3-Phase, 2 leg 1 No Up to 33A Up to 80A Gang 2 units

A419ABG-3C Electronic Temperature Control

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

Application Engineering

Liebert GXT & 6000VA RT230 Rack-Tower models GUIDE SPECIFICATIONS 1.0 GENERAL

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

Electromagnetic Industries LLP


RVS-AX Instruction Manual

Solid State Relays, 3-phase

MCD 200 Series Soft Starters

SOLSTART Instruction Manual

Speed Sensor. Inputs: Safety Information. Outputs. Wiring Diagram. Electrical Data: NOTICE

Max. Output Power. Efficiency (1) 110Vac 220Vac. 450 ma 90 ~ 305 Vac 445 Vdc 200 W 92% EUC-200S045ST

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

Sola 3000 Guide Specifications

3 Uninterruptible Power Systems

Sola/Hevi-Duty S3K Series Mini-Tower UPS

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

Installation and Operations Manual

Installation and Operating Instructions

Test report. Type VRLTC load tap changer VRLTC 1500A Type test summary report

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL MTE Corporation

3 Uninterruptible Power Systems

AC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Dimensions WxHxD [mm] Weight [kg]

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

Installation and Operating Instructions

Subrange SmartWire-DT electronic motor starters. Basic function Reversing starters (complete devices)

Technical specifications

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

D509E. Manual Motor - Starters

AF40... AF96 3-pole contactors Technical data

PATTERSON PUMP COMPANY

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

Reverse power relay and protection assemblies

Designed for ease of integration with automation systems

INSTALLATION INSTRUCTIONS

Easy Multifunctional Safe

Electronic timers CT-E range Selection and ordering details

Electric Actuator Instructions

EPS-ECONOMY PUMP STARTER

KD LV Motor Protection Relay

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Switching Power Supplies

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1

SECTION DC POWER SUPPLY/BATTERY CHARGER

1.1 Caution Statements

Operations Manual. Zero Speed Switch Sensor Model ZS09P

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

MATRIX LLC LEVEL CONTROL PANEL

General Purpose Relay

Power Product Specifications

Flight Systems. Replacement for KASSEC DESCRIPTION

1329I Integrated Drive/Motor CE Filter Option Kit

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

amp ramp Operators Manual Page 1 Saftronics 2S Ltd Turnbridge Mills Quay Street Huddersfield West Yorkshire HD1 6QT

Transcription:

INSTALLATION INSTRUCTIONS Revision A1 Rapid City, SD, USA, 01/2010 MODELS 201A 201A-9 2880 North Plaza Drive, Rapid City, South Dakota 57702 (800) 843-8848 (605) 348-5580 fax (605) 348-5685

BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION. SymCom s MotorSaver Model 201A is an auto ranging plug-in voltage / phase monitor designed to protect 3-phase motors regardless of size. It is used on 190-480 VAC, 50/60 Hz motors to prevent damage caused by single-phasing, low voltage, phase reversal, or voltage unbalance conditions (high voltage detection is only available with the Model 201A-9). CONNECTIONS 1. Locate a convenient location in or near the motor control panel. If the location is wet or dusty, the MotorSaver should be mounted in a NEMA 4 or 12 enclosure. 2. Mount an 8-pin socket to the motor control back panel (SymCom P/N OT08-PC, sold separately, is required for UL rating). 3. Connect L1, L2 and L3 (terminals 3, 4 & 5 on the relay socket) to the LINE SIDE of the motor starter as shown in Figure 1. 4. Connect the output relay to the circuitry to be controlled. For motor control, connect the normally open contact in series with the magnetic coil of the motor starter as shown in Figure 1. For alarm operation, connect the normally closed contact in series with the control circuit as shown in Figure 2. 5. Plug the MotorSaver into the socket. 2010 SymCom, Inc. All Rights Reserved 2

L1 L2 L3 STOP Figure 1: Typical Wiring Diagram L1 L2 L3 LIGHT HORN Figure 2: Alarm/Horn Wiring Diagram 2010 SymCom, Inc. All Rights Reserved 3

SETTINGS Rotate the LINE VOLTAGE ADJUSTMENT to the nominal 3-phase line voltage feeding the motor to be protected. OPERATION After applying power to the MotorSaver, the green RUN light will blink during the restart delay. After the restart delay time has expired, the MotorSaver will energize its output contacts (open the normally closed and close the normally open contacts) and the RUN light will turn solid green. If the contacts do not energize and the RUN light does not turn solid green, see the TROUBLESHOOTING section. INDICATOR LIGHT STATUS GREEN GREEN RUN RESTART DELAY REVERSE PHASE UNBALANCE / SINGLE PHASE (SEE EXAMPLE BELOW) LOW VOLTAGE HIGH VOLTAGE (201A-9 ONLY) Table 1: Diagnostic Indicator Lights Calculating Voltage Unbalance NEMA MG1 Unbalance Formula % Voltage Unbalance = Maximum Deviation from the Average x 100% Average EXAMPLE: The measured line-to-line voltages are 460, 466, and 490. Average = (460 + 466 + 490) = 472 3 The maximum deviation from the average is the largest difference between the average voltage (472) and any one line-to-line voltage. 472-460 = 12 472-466 = 6 490-472 = 18 The maximum deviation from the average is 18. % voltage unbalance = 18 x 100 = 3.8% 472 2010 SymCom, Inc. All Rights Reserved 4

TROUBLESHOOTING SYMPTOM No lights are on - the unit seems completely dead Red light is blinking (on initial power-up) Red light is blinking (after the motor has been running) Red light is blinking in this pattern Red light is blinking in this pattern (201A-9 ONLY) Red light is on steady Green light blinks and motor is not running Green light is on steady, but motor does not start LIGHT PATTERN N/A GREEN GREEN SOLUTION Verify L1, L2 & L3 are connected to terminals 3, 4 & 5. Measure the three line-to-line voltages. If any of the voltages are below 150VAC, the MotorSaver does not have enough power to operate its internal electronics. If the voltages are correct, call SymCom at (800) 843-8848 or (605) 348-5580. Turn off the 3-phase power. Swap any two leads powering the MotorSaver (L1, L2, or L3). There is a 50-50 chance of connecting L1, L2 and L3 correctly the first time. Reapply 3-phase power. The incoming lines have been reverse-phased. The MotorSaver is preventing the motor from running backwards. Correct the phase sequence. The voltage is unbalanced or single-phased. Measure the incoming line voltages and calculate the % unbalance according to the procedure outlined earlier in this document. If the voltage unbalance does not exceed the % unbalance reset value, call SymCom at (800) 843-8848 or (605) 348-5580. The voltage is high. Measure the three line-to-line voltages. If the average voltage is 7% above the line voltage adjustment setting, the MotorSaver is functioning properly. If the voltage is within 7%, call SymCom at (800) 843-8848 or (605) 348-5580. The voltage is low. Measure the three line-to-line voltages. If the average is 7% below the line voltage adjustment setting, the MotorSaver is functioning properly. If the voltage is within 7%, call SymCom at (800) 843-8848 or (605) 348-5580. The MotorSaver is timing through the restart delay and will energize its contacts when finished The MotorSaver is in run mode. Ensure other control devices are allowing the motor to start. Check control circuit for loose wires or malfunctioning switches. 2010 SymCom, Inc. All Rights Reserved 5

DIMENSIONS 1.75 (44.55) 2.375 (60.331) BOT TOM 3.15 (80.01).5 (12.7) SIDE NOTE: Use of the OT08-PC or RB08-PC octal socket, manufactured by Custom Connector Corp., is required for the MotorSaver to qualify as a UL Listed device. The OT08-PC is 35mm DIN rail compatible. 2010 SymCom, Inc. All Rights Reserved 6

MOTORSAVER 201A SPECIFICATIONS Functional Characteristics Low Voltage Trip 90% of setting Reset 93% of setting High Voltage (201A-9 only) Trip 110% of setting Reset 107% of setting Voltage Unbalance Trip 6% Reset 4.5% Trip Delay High/Low Voltage and Unbalance 4 seconds Single-Phasing 2 seconds Restart Delay 2 seconds Input Characteristics Line Supply Voltage Frequency Output Characteristics Output Contact Rating Pilot Duty General Purpose General Characteristics 190 to 480 VAC 50/60Hz 480VA @ 240VAC 10A @ 240VAC Environmental Ambient Operating Temperature 1-40 to 70 C (-40 to 158 F) Relative Humidity 10-95%, non-condensing per IEC 68-2-3 Maximum Input Power 5 W Standards Passed Electrostatic Discharge (ESD) IEC 61000-4-2, Level 3, 6kV contact, 8kV air Radio Frequency Immunity, Radiated 150 MHz, 10V/m Fast Transient Burst IEC 61000-4-4, Level 4, 4kV input power and controls Surge Immunity IEC IEC 61000-4-5, Level 4, 4kV line-to-line; Level 4, 4kV line-to-ground ANSI/IEEE C62.41 Surge and Ring Wave Compliance to a level of 6kV line-to-line Hi-Potential Test Safety Marks UL listed (OT08 octal socket required) Meets UL508 (2 x rated V +1000 V for 1 minute) UL508 (File #E68520) CE IEC 60947-6-2 Dimensions 1.750 H x 2.375 W x 4.125 D (with socket) Weight 9 oz. Enclosure Polycarbonate Mounting Method Plugs into OT08 Socket Wire Gauge 12-22 AWG Solid or Stranded Terminal Torque for P/N OT08 Socket 12 in. - lb 1 The ambient air temperature is the air temperature directly surrounding the product. 2010 SymCom, Inc. All Rights Reserved 7

For warranty information, please see Terms and Conditions at www.symcom.com Visit us at www.symcom.com to see our complete product listing! Need something special? Contact SymCom today for your custom solution! 800-843-8848 2010 SymCom, Inc. All Rights Reserved 8