p-t-sensor Pressure for Mold Cavity Pressure and Temperature with Front ø1 mm Type 6188AA...

Similar documents
Cavity Pressure Sensor

p-t-sensor Pressure PAP for Mold Cavity Pressure and Temperature Type 6190A...

Temperature Sensors. Accessories. for Injection Molding. Types 6192B, 6193B,

Cavity Pressure Sensor

Mold Cavity Pressure Sensor

Miniature Force Sensor

Miniature Force Sensor

PinSens Force Sensor. Force. for mold cavity pressure with diameter 12,6 mm. Type 9204B...

Temperature Sensors. Accessories XST. for Injection Molding. Type 6192A..., 6193A..., 6194A...

Miniature Force Sensor

Cylinder Pressure Sensor

Piezoresistive Pressure Sensor

6001A/B(-H) / 6001B(-H)(-W) / 6002B(-H) / 6002B(-H)(-W) / 6003A/B(-H) / 6003A/B(-H)(-W)/ 6006BC(-W) / 6007BC / 6007BC(-W) / 6008AA / 6010BC(-W)

MN Press Force Calibration Sensor

Piezoresistive Absolute Pressure Sensor

Measuring Spark Plug M10x1

Piezoresistive Absolute Pressure Sensors

Piezoresistive high pressure sensor

Combustion Monitoring with Pressure Sensors.

Pressure SUNSTAR 传感与控制 TEL: FAX: Measuring Spark Plug M14x1,25 with Integral

Reaction Torque Sensor

RoaDyn P: 1-Component Wheel Torque Transducers

Universal absolute pressure sensor

9301B 9311B 9321B 9331B 9341B 9351B 9361B 9371B

M10x1 Measuring Spark Plug

RoaDyn S: Multi-Component Test Stand Hubs

RoaDyn S625 System 2000

RoaDyn S635 System 2000

Piezoresistive high pressure sensor

Weatherproof Tubular Slip Ring Assembly

Pressure Sensors for Test and Measurement. For Precise Pressure Measurement in Static and Dynamic Applications

The Piezoresistive Pressure Transducer

Easily monitor road usage

Easily monitor road usage

M14x1,25 Measuring Spark Plug

Cars, The high measuring accuracy of the precision load cells is retained during transmission, since digitization takes place on the wheel to

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

measure. analyze. innovate.

Model 6A Series 6-Axis Load Cells (Fx Fy Fz Mx My Mz)

KiTorq Stator. Torque. Torque Evaluation Unit (Stator) for a Torque Measuring Flange. Type 4542A...

PRESSURE BENCH OPERATING INSTRUCTIONS

8710 EN. Potentiometric Displacement Sensors. Models 8710, 8711

Electromagnetic Flow Monitor magphant

Targeted Applications AutoPSI Dynamic Pressure Sensors AutoPSI-DC Static Pressure Sensors PSIplug/CALplug PSIglow

Screw-in melt thermocouples

MGL Avionics EFIS G2 and iefis

Instruction Manual Basic Line Torque Sensor Type 4520A...

MOBILE MEASUREMENT TECHNOLOGY

LIFTKET wire rope winch with wall bracket or foot support

Witold Perkowski, Andrzej Irzycki, Micha Kawalec Borys ukasik, Krzysztof Snopkiewicz

Electronic Monitoring Systems

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

Defining Parameters for Ballistic High Pressure Sensors. Transducer Workshop June 20-21, 2000 Aberdeen, MD

Screw-in Thermocouples

NC Joining Module NCFN

Electronic Monitoring Systems

SATRON VTe pressure transmitter

Load Cells SIWAREX WL230 BB-S SA

High temperature sensors

Actuated Valves PRICING

PRODUCT IDENTIFICATION & COMPANY

three different ways, so it is important to be aware of how flow is to be specified

Machine shut-off nozzle for Elastomer; Type-E Integrated actuator and tempering system

DART. Operation / Installation Manual. Digital Analog Remote Transducer. Computer Weld Technology, Inc. Manual Part Number: A8M5015 Revised: 9/28/2004

FORCE SENSORS FORCE SENSORS

BNC and MHV SHV-5 and SHV-10 SHV-20 and SHV-B

Coaxial Attenuators Low, medium and high power

Compact Vacuum Regulator. How to Order. Nil. ATMc. Base type Nil M

Technical Datasheet P-30/P-31. Standard transmitter.

Confidence in measurement.

How to Order ITV N. Nil. EXHc. Base type. Nil. ø1/4"

ROSTA Tensioning Motorbases Type MB. self-adjusting maintenance-free overload-proof non-slip dampen harmful vibrations extend belt drive

CONVENTIONAL WORKHOLDING

Hot runner thermocouple Model TC46

SP4 DOCUMENTATION. 1. SP4 Reference manual SP4 console.

Load Cell for Manually Operated Presses Model 8451

Thermocouples TE Measuring Insert. rigid Model TC 001 flexible Model TC 002. Electronic Temperature Measurement

INTERNATIONAL METAL ENGINEERING

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

ELECTRONIC MONITORING SYSTEMS AND TEMPERATURE SENSORS

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold

Directional servo-valve in 4-way design

CATALOG. Actuated Diaphragm Valve DN PVC-U / PVC-C / PP-H / PVDF / ABS SMART IN FLOW CONTROL.

Drivers for Pockels Cells

Promix Solutions trust the leader. Static Mixers Solutions for Injection Molding

Differential Pressure and Flow meters Accessories for the Media Series

Measuring equipment for the development of efficient drive trains using sensor telemetry in the 200 C range

The platform is placed on the weighing platform using three or four height-adjustable elastomer bearings (EL 120), in order to avoid twisting.

Modular resistance thermometer - Quicktemp TP60/TW39...T500 -

Applications. Measuring and analyzing pressure, force and acceleration

- Quicktemp TP62/TW39...T500 -

Electro-Pneumatic Regulator Electronic Vacuum Regulator

hotrod Cartridge Heaters

Cable thermocouple Model TC40

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

JUMO MIDAS S05 Pressure transmitter Type

SP38D Piezoresistive single crystal silicon differential pressure sensor

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Mineral Insulated Resistance Thermometers (RTD)

Diesel engine dial thermometers

Transcription:

Pressure p-t-sensor Type 6188AA... for Mold Cavity Pressure and Temperature with Front ø1 mm Sensor for combined measuring of mold cavity pressure up to 2 000 bar and contact temperature in the cavity is designed for injection molding of plastics. Design without diaphragm but with flat front. Pressure sensor with integrated thermocouple for pressure and temperature measurement Mounting dimensions compatible with Kistler pressure sensor Type 6183A... Sensor cable replaceable by Kistler factory Description The Sensor for mold cavity pressure and temperature has a front diameter of 1 mm. The pressure acts over the entire front of the sensor and is transmitted to the crystal measuring element, which produces a proportional electric charge (pc = Picocoloumb). This is converted into a voltage 0... 10 V in the amplifier and is then available as an amplifier output. industrial applications for optimising monitoring and controlling the injection molding of thermoplastics and elastomers. The additional temperature data provides valuable process information. This is particularly useful in the analysis of part dimensions, as well as in the evaluation of knit lines in components. 6188AA_000-887e-01.11 The contact temperature of the melt is measured on the front of the sensor by one pair of thermocouples, type K (NiCr-Ni). The sensor front can not be machined. The small sensor dimensions result in a short response time of the temperature sensor. The rugged combi-cable feeds the pressure signal as well as the temperature signal to two connectors. Sensors without connectors Type 6188AAG are available for multi-cavity molds. The charge cable can then be connected to the multi-channel connector Type 1708A or 1710A... and the two temperature conductors to the temperature amplifier Type 2205A. Application Suggested applications are complex and compact injection molds in the field of medical, electrical and precision molding industries. The sensor measures the mold cavity pressure and the contact temperature of the molding in the cavity. It is suitable in Technical Data Range bar 0... 2 000 Overload bar 2 500 Sensitivity pc/bar 4,8 Linearity, all ranges %FSO ±1 Thermocouple, Type K NiCr-Ni Operating temperature range Mold (Sensor, cable, connector box) C *0... 200 Melt (at the front of the sensor) C <450 Insulation resistance at 20 C TΩ 100 at 200 C TΩ 1 * During machine down-time, the mold temperature may be allowed to rise to 240 C without damaging the sensor. However, measuring errors may occur. Page 1/4 2010... 2011, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland

p-t-sensor for Mold Cavity Pressure and Temperature with Front: ø 1mm, Type 6188AA... Cable and Amplifier for Measuring Chain with Sensor Type 6188AA... Cable Type 1667B... Cable Type 1672B... Compensating Line Compensating Line Type 2290A... (BNC connector) for charge (TNC connector) for charge Type 2295A... for Temperature (Open Ends) for Temperature Type 5155AxxBx Type 5155AxxAx Type 5155AxxAx Type 2207A in Type 2859A... Type 5155AxxDx Type 5155AxxCx Type 5155AxxBx Type 2207A in Type 2865A... Type 5063A1 in Type 2859A... Type 5155AxxCx Type 5063A1 in Type 2865A... Type 5155AxxDx Fig. 1: Sensor Type 6188AA... with charge and temperature amplifier Type 5155A... or signal contitioner Type 2859/2865A... 6188AA_000-887e-01.11 4-Channel Cable Type 1995A... to Connector Type 1708A... for Charge Type 2869A/B0xx Type 2869A/B1xx 4-Channel Cable Type 1457A1A... to Temperature Amplifier Type 2205A... for Temperature Type 2869A1xx Type 2869B... Fig 2: Sensor Type 6188AA... with monitoring system CoMo Injection Type 2869... Page 2/4 2010... 2011, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland

p-t-sensor for Mold Cavity Pressure and Temperature with Front: ø 1mm, Type 6188AA... Fig. 3: Sensor Type 6188AA... with connectors for pressure and temperature signal Installation Examples 6188AA_000-887e-01.11 Fig. 4: Mounting with spacer sleeve Type 6464A3 Fig. 5: Mounting plate (Art. No. 3.520.1015) Page 3/4 2010... 2011, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland

p-t-sensor for Mold Cavity Pressure and Temperature with Front: ø 1mm, Type 6188AA... Mounting The sensor is installed with the spacer sleeve Type 6464A3 in the stepped hole. Since the sensor forms part of the cavity wall, it must be installed in such a way that its front is exactly flush. The sensor is centered in the diameter 2,5 mm/h7 hole. Optional connectors and temperature amplifiers To be used only with Type 6188AAG 4-channel connector (charge) 1708A... 8-channel connector (charge) 1710A... 2-channel temperature amplifier 2205A121 2-channel temperature amplifier 2205A141 Cable stripping tool 1367 The cable must be installed completely in the mold. The two connectors are attached in the mounting plate which is mounted into the mold. The combi-cable uses the single-wire technique, i.e. the pressure signal is transferred via a single cable and the mold acts as a shield. Ordering Key Basic Type Type 6188A A Accessories Included Type/Art.No. Spacer sleeve (L = 50 mm) 6464A3 Mounting plate 3.520.1015 Connector (charge) 5.511.364 Connector (temperature) 5.511.246 Cap (2 pieces) 7.621.115 Checking tool 3.050.241 Identification plate 3.520.1016 Optional Accessories High-temperature extension cable (pressure) Fischer SE102 A014 BNC pos. Type/Art.No. 1667B2 1667B5 Cable length (L = 0,4 m) 0,4 Cable length (L = 0,8 m) 0,8 Cable length (L = 1,2 m) 1,2 Cable length (L = 1,6 m) 1,6 Cable length (L = 2,0 m) 2 Combi-cable with special length, specify cable sp length L in m (L min = 0,15 m / L max = 3,5 m) Sensor without connector, Cable length l = 2,0 m G High-temperature extension cable (pressure) Fischer SE102 A014 TNC pos. 1672B2 1672B5 6188AA_000-887e-01.11 Compensation lead (Temperature) Connection for Type 5155A... Compensation lead (Temperature) One way open ended 2295A2 2295A5 2290A2 2290A5 Extraction tool 1358A Dummy sensor 6579 Page 4/4 2010... 2011, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland

Pressure p-t-sensor Type 6189A... for Mold Cavity Pressure and Temperature with Front ø2,5 mm Sensor for combined measuring of mold cavity pressure up to 2 000 bar and contact temperature in the cavity is designed for injection molding of plastics. Design without diaphragm but with flat front. Pressure sensor with integrated thermocouple for pressure and temperature measurement Mounting dimensions compatible with Kistler pressure sensors 6182A and 6158A... Sensor cable replaceable by Kistler factory Description The Sensor for mold cavity pressure and temperature has a front diameter of 2,5 mm. The pressure acts over the entire front of the sensor and is transmitted to the quartz measuring element, which produces a proportional electric charge (pc = Picocoloumb). This is converted into a voltage 0... 10 V in the amplifier and is then available as an amplifier output. tional temperature data provides valuable process information. This is particularly useful in the analysis of the surface of the molding, as well as in the evaluation of knit lines in components with long flow paths. 6189A_000-536e-02.11 The contact temperature of the melt is measured on the front of the sensor by one pair of thermocouples, type K (NiCr-Ni). The sensor front can not be machined. The small sensor dimensions result in a short response time of the temperature sensor. The rugged combi-cable feeds the pressure signal as well as the temperature signal to two connectors. Sensors without connectors Type 6189AG are available for multi-cavity molds. The charge cable can then be connected to the multi-channel connector Type 1708A or 1710A and the two temperature conductors to the temperature amplifier Type 2205A. Application The sensor measures the mold cavity pressure and the contact temperature of the molding in the cavity. It is suitable in industrial applications for optimising monitoring and controlling the injection molding of thermoplastics and elastomers. The addi- Technical Data Range bar 0... 2 000 Overload bar 2 500 Sensitivity pc/bar 6,5 Linearity, all ranges %FSO ±1 Thermocouple, Type K NiCr-Ni Operating temperature range Mold (Sensor, cable, connector box) C *0... 200 Melt (at the front of the sensor) C <450 Insulation resistance at 20 C TΩ 100 at 200 C TΩ 1 * During machine down-time, the mold temperature may be allowed to rise to 240 C without damaging the sensor. However, measuring errors may occur. Page 1/4 2006... 2011, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland

p-t-sensor for Mold Cavity Pressure and Temperature with Front: ø 2,5 mm, Type 6189A... Cable and Amplifier for Measuring Chain with Sensor Type 6189A... Cable Type 1667B... Cable Type 1672B... Compensating Line Compensating Line Type 2290A... (BNC connector) for charge (TNC connector) for charge Type 2295A... for Temperature (Open Ends) for Temperature Type 5155AxxBx Type 5155AxxAx Type 5155AxxAx Type 2207A in Type 2859A... Type 5155AxxDx Type 5155AxxCx Type 5155AxxBx Type 2207A in Type 2865A... Type 5063A1 in Type 2859A... Type 5155AxxCx Type 5063A1 in Type 2865A... Type 5155AxxDx Fig. 1: Sensor Type 6189A... with charge and temperature amplifier Type 5155A... or signal contitioner Type 2859/2865A... 6189A_000-536e-02.11 4-Channel Cable Type 1995A... to Connector Type 1708A... for Charge Type 2869A/B0xx Type 2869A/B1xx 4-Channel Cable Type 1457A1A... to Temperature Amplifier Type 2205A... for Temperature Type 2869A1xx Type 2869B... Fig 2: Sensor Type 6189A... with monitoring system CoMo Injection Type 2869... Page 2/4 2006... 2011, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland

p-t-sensor for Mold Cavity Pressure and Temperature with Front: ø 2,5 mm, Type 6189A... Fig. 1 : Sensor Type 6189A... with connectors for pressure and temperature signal Installation Examples 6189A_000-536e-02.11 anpassen Fig. 2: Mounting with spacer sleeve Type 6464A3 Fig. 3: Mounting plate (Art. No. 3.520.1015) Page 3/4 2006... 2011, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland

p-t-sensor for Mold Cavity Pressure and Temperature with Front: ø 2,5 mm, Type 6189A... Mounting The sensor is installed with the spacer sleeve Type 6464A3 in the stepped hole. Since the sensor forms part of the cavity wall, it must be installed in such a way that its front is exactly flush. The sensor is centered in the diameter 2,5 mm/h7 hole. The cable must be installed completely in the mold. The two connectors are attached in the mounting plate which is mounted into the mold. The combi-cable uses the single-wire technique, i.e. the pressure signal is transferred via a single cable and the mold acts as a shield. Accessories Included Type/Art.No. Spacer sleeve (L = 50 mm) 6464A3 Mounting plate 3.520.1015 Connector (charge) 5.511.364 Connector (temperature) 5.511.246 Cap (2 pieces) 7.621.115 Checking tool 3.050.243 Identification plate 3.520.1016 O-ring 1100A55 Optional connectors and temperature amplifiers To be used only with Type 6189AG 4-channel connector (charge) 1708A... 8-channel connector (charge) 1710A... 2-channel temperature amplifier 2205A121 2-channel temperature amplifier 2205A141 Cable stripping tool 1367 Ordering Key Type 6189A Cable length (L = 0,4 m) 0,4 Cable length (L = 0,8 m) 0,8 Cable length (L = 1,2 m) 1,2 Cable length (L = 1,6 m) 1,6 Cable length (L = 2,0 m) 2 Combi-cable with special length, specify cable sp length L in m (L min = 0,15 m / L max = 3,5 m) Sensor without connector, Cable length l = 2,0 m G Optional Accessories High-temperature extension cable (pressure) Fischer SE102 A014 BNC pos. High-temperature extension cable (pressure) Fischer SE102 A014 TNC pos. Type/Art.No. 1667B2 1667B5 1672B2 1672B5 6189A_000-536e-02.11 Compensation lead (Temperature) Connection for Type 5155A... Compensation lead (Temperature) One way open ended 2295A2 2295A5 2290A2 2290A5 Extraction tool 1358A Dummy sensor 6558 Page 4/4 2006... 2011, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland

Pressure p-t-sensor Type 6190CA... for Mold Cavity Pressure and Temperature with Front ø4 mm Sensor for the combined measurement of mold cavity pressure up to 2 000 bar and contact temperature in the cavity during the injection molding of plastics. Design without diaphragm and with flat front. Pressure sensor with integral thermocouple for pressure and temperature measurement Mounting dimensions compatible with Kistler pressure sensors Types 6157B and 6177A Replaceable connecting cable Description The sensor for mold cavity pressure and temperature measurement has a front face of 4 mm diameter. The pressure acts directly on the entire front face of the sensor and is transferred to the crystal force link, which produces an electric charge (pc = picocoulomb) proportional to the pressure. This is converted by an amplifier into a voltage of 0 10 V which is available at the amplifier output. This is particularly useful in the analysis of the surface of the molding, as well as in the evaluation of knit lines in components with long flow paths. 6190CA_000-680e-01.14 The contact temperature of the melt is measured on the front side of the sensor by a thermocouple pair Type K (NiCr-Ni). The front face of the sensor cannot be machined. The small sensor dimensions result in a quick temperature-sensor response time. The rugged combi-cable feeds both the pressure signal and the temperature signal to two connectors. The cable is screwed behind the sensor with a union nut and can be exchanged. Sensors without connectors Type 6190CAG are available for multi-cavity molds. The charge cable can then be connected to the multi-channel connector Type 1708 or 1710... and the two temperature conductors to the temperature amplifier Type 2205A. Application The sensor measures the mold cavity pressure and the contact temperature of the molding in the cavity. It is suitable in industrial applications for optimising monitoring and controlling the injection molding of thermoplastics and elastomers. The additional temperature data provides valuable process information. Technical Data Range bar 0.. 2 000 Overload bar 2 500 Sensitivity pc/bar 9 Linearity, all ranges %FSO ±1 Thermocouple Type K NiCr-Ni Leads positive + green negative white Operating temperature range Mold (sensor, cable, connector housing) C *0... 200 Melt (at the front of the sensor) C <450 Insulation resistance at 20 C Ω >10 13 at 200 C Ω >10 12 * During machine down-time, the mold temperature may be allowed to rise to 240 C without damaging the sensor. However, measuring errors may occur. Page 1/4 2008... 2014, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland

p-t-sensor for Mold Cavity Pressure and Temperature with Front ø4 mm, Type 6190CA Cable and Amplifier for Measuring Chains with Sensor Type 6190CA Charge Amplifier Type 5159 Pressure Sensor 1 Sensor 2 Sensor 1... 4 Sensor 3 Sensor 4 Power / Digital I/O / Analog Output Cable Type 1667B... Cable Type 1672B... Compensating line Compensating line Type 2290A... (BNC connector) for charge (TNC connector) for charge Type 2295A... for temperature (open ends) for temperature Type 5155AxxBx/AxxDx Type 5155AxxAx Type 5155AxxAx/AxxBx Type 5155AxxCx Type 5155AxxCx/AxxDx Type 2205A in Type 2865A... Fig. 1: Sensor Type 6190CA... with charge and temperature amplifier Type 5155A... 6190CA_000-680e-01.14 4-channel cable Type 1995A... to connector Type 1708... for charge Type 2869B0xx Type 2869B1xx 4-channel cable Type 1457A1A... to temperature amplifier Type 2205A... for temperature Type 2869B1xx Fig. 2: Sensor Type 6190CA... with monitoring system CoMo Injection Type 2869A... Page 2/4 2008... 2014, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland

p-t-sensor for Mold Cavity Pressure and Temperature with Front ø4 mm, Type 6190CA Mounting Examples Fig. 3: Sensor Type 6190CA with cable separable Type 2219B... and connectors for pressure and temperature signal 6190CA_000-680e-01.14 to adjust to adjust Fig. 4: Mounting with mounting nut Type 6457 Fig. 5: Mounting with spacer sleeve Type 6459 Fig. 6: Mounting plate Art. No. 3.520.1015 Page 3/4 2008... 2014, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland

p-t-sensor for Mold Cavity Pressure and Temperature with Front ø4 mm, Type 6190CA 6190CA_000-680e-01.14 Mounting The sensor is normally installed in the mounting hole with a mounting nut Type 6457. A spacer sleeve Type 6459 can also be used. Since the sensor forms part of the cavity wall, it must be mounted in such a way that its front face is exactly flush. The sensor is therefore center aligned in the hole with 4mm/H7 diameter. The cable must be mounted completely in the mold. The two connectors are attached in the mounting plate which is inserted in the mold. The multiconductor cable uses the single-wire technique, that is the pressure signal is fed via a single cable and the mold acts as a shield. Accessories Included Type/Art. No. Mounting nut 6457 Mounting plate (only for sensor with cable) 3.520.1015 Connector (charge) 5.511.364 Connector (temperature) 5.511.246 Cap 7.621.115 Identification plate 3.520.1016 O-ring 1100A57 Optional Accessories Type Sensor connecting cable with connectors as spare cable Length l = 0,4 m 2219B0,4 Length l = 0,8 m 2219B0,8 Length l = 1,2 m 2219B1,2 Length l = 1,6 m 2219B1,6 Length l = 2 m 2219B2 Length l = 5 m for special cable length 2219Bsp Sensor connecting cable without connector as spare cable Length l = 2 m Length l = 5 m for special cable length High temperature extension cable (pressure) Fischer SE102 A014 BNC pos. Length l = 2 m Length l = 5 m High temperature extension cable (pressure) Fischer SE102 A014 TNC pos. Length l = 2 m Length l = 5 m Temperature compensation cable for connection to Type 5155A Length l = 2 m Length l = 5 m 2219BG 2219BG1 1667B2 1667B5 1672B2 1672B5 2295A2 2295A5 Optional Accessories Temperature compensation cable One way open ended Length l = 2 m Length l = 5 m Type 2290A2 2290A5 Extraction tool 1315A Socket wrench for mounting nut 1383 Dummy sensor 6545 Spacer sleeve (length l = 70 mm) 6459 Optional connectors and temperature amplifiers To be used only with Type 6190CAG/G1 4-channel connector (charge) 1708... 8-channel connector (charge) 1710... 2-channel temperature amplifier 2205A...2... 4-channel temperature amplifier 2205A...4... Adapterplatte für 2 Stecker 5700A25 Cable stripping tool 1367 Checking Tools Art. No. Limit plug gage, diameter 4 H7 5.210.162 Checking tool 7.110.300 Ordering Key Type 6190CA Cable Length Length l = 0,4 m 0,4 Length l = 0,8 m 0,8 Length l = 1,2 m 1,2 Length l = 1,6 m 1,6 Length l = 2 m 2 Combi-cable with special length, sp specify cable length L in m (L min = 0,15 m/l max = 5 m) Sensor without connector, Cable length l = 2 m G Sensor without connector, Cable length l = 5 m G1 Page 4/4 2008... 2014, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland