OWNER S MANUAL. Evolution Series Fountain. 1/2 hp, 115V, 60 Hz

Similar documents
OWNER S MANUAL. Evolution Series Fountain. 1/2 hp, 115V, 60 Hz

Manual PN: Rev 01. Otterbine Barebo Inc. Fractional Series 50Hz Installation Manual

Otte. erbine Frac. ctiona anuall

AUTOMATIC SUBMERSIBLE UTILITY PUMP

SUBMERSIBLE SUMP PUMPS

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

SUNC3000 / Item #40885

Level One Electric Vehicle Charging Station FREE STANDING Product Guide

GARDEN HOSE UTILITY PUMP

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

Submersible Waterfall Pump 1200 Gallons Per Hour

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

SPC-PANEL Simplex, Single Phase Pump Control Panel

StormPro BA Series Sump Pump

SUBMERSIBLE SUMP PUMPS

8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995

Pump Installation and Service Manual HRS Hydromatic Retractable System

INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR MODELS K4RP & K4VP SUBMERSIBLE SOLIDS-HANDLING SEWAGE PUMPS

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

Helios. 24 Light 240 Volt Controller. PRODUCT # Instruction Manual.

Container Fountain Kit with LED Light

Submersible Pond Pump with UV 800 Gallons Per Hour

Natural Fiber Planter Fountain

Premium Pond Pump 330 Gallons Per Hour

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

SLAB SAW SERIES PARTS LIST

Level One Electric Vehicle Charging Station Wall Mount Product Guide

Powerful & Intelligent Submersible Pumps

OPERATOR S MANUAL. MODEL ORDER # MODEL HD 2.0/10 Ed HE D HD 1.8/14 Ed HE D

OWNER S MANUAL STOP. Models: Blade Master 1.5 HP 1500 Series Stationary Transfer Pump 1.5 Pump, Single Phase AC 110/220V, Non-Explosion proof

HP30 Slab Saw Owner s Manual and Operating Instructions

Premium Waterfall Pump 1200 Gallons Per Hour

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

Integrated Heating System

StormPro BCV400 Sewage Ejector Pump

4400JF (120V) Aerating Fountain Specifications

4-Ton Electric Log Splitter

LIFT NAME PART NUMBER SETBACK (min) SETBACK (max)

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS

OPERATOR S MANUAL HD 2.3/24 P CD HD 2.3/23 P CD

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

Installation and Operation Manual

SuperFlo 9,000 High Volume Pump Product Manual

Air Compressor. Owner s Manual

450250/ ROOSTER WINCH Installation Manual

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

Series: PFSWCPC75. 3/4 HP 1750 RPM 60 Hz Submersible Sewage Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

Read this entire manual before operation begins.

MetroPrime 22MPC Self-Priming Centrifugal Pump

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

PRE-PLUMBED SEWAGE SYSTEM

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

Read and follow all instructions. Safety can only be ensured if the walker is assembled and operated according to these instructions.

Ion Technologies SHR-HR Submersible Sewage Pump Single Seal, Single Phase, & Three Phase Power

Users Manual Certified Series Direct Drive Pump 1-7 LPM

PIAA Multi-Fit 005/1100X Light Bracket Kits

Illumifalls Patio Pond

RENEGADE SLATE BUMPER POOL TABLE ASSEMBLY INSTRUCTIONS

Important Information

Installation Instructions

HV200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

PPM EO-100 TM. Operation Manual

Service Guide JATCO Environmental Protection Tank Model J-7000

HALLMARK INDUSTRIES INC

Installation Instructions. Fog Lights. The lamps get very hot when they have been in use. Do not touch them as they may cause burns.

RK Standby Battery Operator s Manual

Read this entire manual before operation begins.

WATERBLAST HOSE REEL SYSTEM HWB HOSE REEL OPERATION AND MAINTENANCE MANUAL W A T E R J E T T O O L S

MODEL TC400 TIRE CART. Installation, Operation & Repair Parts Information REV P/N:

SUPER PUMP OUT SYSTEM

V2 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

DC-AC Power Inverter SAM Manual. Please read this manual before installing your inverter

WARNING! Buyer/user assumes all responsibility for safety and proper use not in accordance with the directions and safety labels.

HUSTLER 7' & 8' POOL TABLE ASSEMBLY INSTRUCTIONS

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

SUBMERSIBLE SWIMMING POOL DRAINER

10 Year Limited Warranty

MAVERICK 7' POOL TABLE WITH TABLE TENNIS ASSEMBLY INSTRUCTIONS

Operating Manual Includes Pumps: PG-9000 Part #R809606

Power. On Your Terms.

WARNING! Buyer/user assumes all responsibility for safety and proper use not in accordance with the directions and safety labels.

DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131

AQUASONIC POOL SPEAKER INSTALLATION GUIDE

MODELS WGL20, WGL20H and WGL20F

Aerator Model 1812AF Owners Manual

L-SERIES PUMPS. Operating Manual. Includes Pumps: L-305 L PONDS

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

ATD Gallon Pressurized Oil Drain Owner s Manual

SUBMERSIBLE MINI-PUMP

DRAIN PUMP SYSTEM MODEL 105 (Korean) INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

Water Jetter Units DU JT50 / DU JT100

Instruction Manual. Fudge Puppy Display Case

Submersible Waterfall Pump 1250 Gallons Per Hour

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

ULTRAWARMER HOLDING STATION INSTALLATION & OPERATIONS MANUAL

Transcription:

OWNER S MANUAL Aqua Control, Inc. 6A Wolfer Industrial Drive Spring Valley, IL 66 Ph: 5.66.900 00.77.009 Fax: 5.66.90 www.aquacontrol.com Evolution Series Fountain / hp, 5V, 60 Hz

SAFETY INSTRUCTIONS IMPORTANT: Reading and understanding these instructions and warranty disclaimer are necessary prior to product installation and operation. Under NO circumstances should anyone enter the water with the electrical equipment plugged in and/or in operation. NEVER run the unit out of water. It will damage the seals and create a dangerous situation for the operator. NEVER lift or drag the fountain by the power or light cord. The fountain suction screen should be inspected for clogging on a monthly basis. If matted weeds, leaves or plastic bags are present, remove them with a bristle brush. Failure to keep the suction screen clear of blockages will cause low water flow and cause the fountain motor to fail. This type of failure is NOT covered under the Aqua Control, Inc. warranty. In freezing conditions, the fountain must be removed from the water body and stored in an area above F. Aqua Control. Inc. or its distributors are not liable for electrician's fees incurred for troubleshooting electrical issues. TABLE OF CONTENTS Safety Assembly & Start Up Instructions Fountain Control-Timer Programming Maintenance & Accessory Installation 5 Evolution Parts List 6 Optional Lighting Parts List 7 Stationary Assembly Instructions & Parts List Troubleshooting Guide Torrent Pattern Conversion 9 Warranty Disclaimer 0 OPTIONAL ACCESSORIES LIGHTING KIT LIGHTS NOZZLE KIT FLOW STRAIGHTENER MOUNTING BRACKETS MOUNTING FASTENERS JUNCTION BOX (PLUGS INTO CONTROL BOX SUPPLIED WITH FOUNTAIN) EV6-L-050 (INCLUDES 50 FOOT POWER CORD) EV6-L-00 (INCLUDES 00 FOOT POWER CORD) EV6-L-75 (INCLUDES 75 FOOT POWER CORD) NOZZLE ARUM #EV6-N-0.50-ARU CLUSTER ARCH # EV6-N-0.50-CLA FLEUR de LIS #EV6-N-0.50-FLE METRO #EV6-N-0.50MET SPIDER & ARCH #EV6-N-0.50-SAR TIARA #EV6-N-0.50-TIA GUSHER (STATIONARY ONLY) #EV6-N-0.50-G GUSHER (STATIONARY ONLY) #EV6-N-0.50-G GUSHER 6 (STATIONARY ONLY) #EV6-N-0.50-G6 MOUNTING FASTENERS

QUICK STARTUP INSTRUCTIONS STEP# ALIGN NOTCH IN FOUNTAIN WITH SLOT IN FLOAT AND INSERT PUMP CORD AND FOUNTAIN KEEP DRY STEP# MEASURE AND CUT MOORING ROPES TIE TO FLOAT KEEP DRY STEP# TIE MOORING LINES MOORING STAKES STEP#5 PLUG FOUNTAIN INTO CONTROL BOX, PLUG CONTROL BOX INTO 5 OR 0 AMP 5 VOLT RECEPTACLE MOORING STAKE THIS FACE TOWARDS FOUNTAIN MOTOR CORD TO CONTROL MOORING ROPE MOORING STAKE STEP# PULL FOUNTAIN TO DESIRED LOCATION IN POND. DRIVE IN MOORING STAKES. KEEP MOTOR AND LIGHTING CORD PLUGS DRY SUBMERSIBLE MOTOR CORD MOORING ROPE

FOUNTAIN CONTROL-TIMER PROGRAMMING FOUNTAIN CONTROL ON GREEN OFF RED STEP#7 TESTING GROUND FAULT INTERUPT(GFCI) TRIPPER PINS SEE STEP# STEP# PLUG IN LIGHTS (OPTIONAL SOLD SEPERATELY) STEP#5 PLUG CONTROL BOX INTO STANDARD 5V HOUSEHOLD OUTLET STEP# PLUG IN FOUNTAIN STEP#6 TURN ON CONTROL PUSH TO TEST PUSH TO RESET STEP# SET CORRECT TIME-OF-DAY STEP# SET ON/OFF TIMES (SEE TRIPPER PINS ABOVE) > Evolution Series Fountain / HP, 5V, 60 Hz

MAINTENANCE AND ACCESSORY INSTALLATION PLUGGED SUCTION SCREEN IF YOUR SUCTION SCREEN BECOMES PLUGGED BY POND WEEDS OR OTHER DEBRIS. CAUTION!! BEFORE YOU BEGIN, DISCONNECT FROM POWER (UNPLUG FROM CONTROL) SUCTION SCREEN OPTIONAL NOZZLE INSTALLATION INSERT SCREWS IN NOZZLE FLANGE AND THREAD INTO THROAT FLANGE FLOW STRAIGHTENER SCREWS NOZZLE REINFORCING RING SCRUBB WITH PLASTIC BRISTLE BRUSH TO REMOVE DEBRIS. INSERT FLOW STRAIGHTENER IN THROAT REINFORCING RING SIDE UP THROAT OPTIONAL LIGHT PACKAGE INSTALLATION (Light U-bracket placement shown at the bottom of the float. Brackets may be mounted with the U-brackets at top or bottom of float.) WASHERS UPPER BRACKET SLOT LIGHT BRACKET PLACE BRACKET IN SLOT MOUNT LIGHTS ON BRACKETS BRACKET NUT ROTATE BRACKET SNAP BRACKET INTO LOWER FLOAT SLOT SUBMERSIBLE JUNCTION BOX PLUG INTO FOUNTAIN CONTROL 5

EVOLUTION PARTS LIST ITEM= A B C D E F G PART= DESCRIPTION EV-H-KIT HARDWARE KIT (INCLUDES ITEMS A THRU K) EV-H-MSP-0.75 /-5 X / PAN HEAD HI-LOW SCREW EV-H-HN- MM HEX NUT MM LOCK WASHER EV-H-LW- EV-H-FW- MM FLAT WASHER EV-H-HHB-.50 /-0 X / HEX HEAD CAP SCREW EV-H-LW-0.5 / LOCK WASHER EV-H-MSP-0.75 /-0 X / PAN HEAD MACHINE SCREW OPTIONAL LIGHTING HARDWARE (INCLUDED IN HARDWARE KIT) H EV-H-FW-5 I J K EV-H-LW-5 5MM LOCK WASHER EV-H-NC-5 5MM ACORN NUT MM X 6 FLAT HEAD MACHINE SCREW EV-H-MSF-X6 NOZZLE KIT (INCLUDES NOZZLE, FLOW STRAIGHTENER & FASTENERS) EV6-N-0.50-ARU /HP ARUM NIOZZLE KIT EV6-N-0.50-CLA /HP CLUSTER ARCH NOZZLE KIT EV6-N-0.50-FLE /HP FLEUR di LIS NOZZLE KIT EV6-N-0.50-MET /HP METRO NOZZLE KIT EV6-N-0.50-SAR /HP SPIDER & ARCH NOZZLE KIT EV6-N-0.50-TIA /HP TIARA NOZZLE KIT EV6-N-0.50-G /HP GUSHER (STATIONARY ONLY) EV6-N-0.50-G /HP GUSHER (STATIONARY ONLY) /HP GUSHER 6 (STATIONARY ONLY) EV6-N-0.50-G6 EV-R-THROAT EVOLUTION THROAT EV-H-FW-PROP PROPELLER WASHER EV6-R-P-0.50 /HP PROPELLER E 6 EV-R-SPACER MOTOR SPACER 5 7A 7B 7C EV6-MA-0.50-050 EV6-MA-0.50-00 EV6-MA-0.50-75 REPLACEMENT MOTOR OPTIONS /HP MOTOR WITH 50' CORD & MOLDED PLUG /HP MOTOR WITH 00' CORD & MOLDED PLUG /HP MOTOR WITH 75' CORD & MOLDED PLUG 6 A MOTOR CORD OPTIONS (INCLUDES MOTOR CORD, MOLDED PLUG) EV6-R-MC-050-F 50' MOTOR CORD B C 9 0 EV6-R-MC-00-F EV6-R-MC-75-F EV-R-SCREEN EV-R-FLOAT EV6-R-CB EV-R-ANCHOR EV-R-ROPE 5 5MM FLAT WASHER QTY 00' MOTOR CORD 75' MOTOR CORD EVOLUTION SUCTION SCREEN EVOLUTION FLOAT CONTROL BOX WITH 6' CORD & MOLDED PLUG EVOLUTION MOORING STAKES 00' BALCK MORRING ROPE A B C C D F 7A 7B 7C A B C G 9 0 6

OPTIONAL LIGHTING PARTS ITEM= PART= DESCRIPTION QTY LIGHT CORD OPTIONS (INCLUDES SPLICE KIT & MOTLDED PLUG) A EV6-R-LC-050 50' LIGHT CORD B EV6-R-LC-00 00' LIGHT CORD C EV6-R-LC-75 75' LIGHT CORD 5 EV-R-LJB- LIGHT JUNCTION BOX WITH 6' CORD & SPLICE KIT 6 EV-R-LGT-BKT EVOLUTION LIGHT BRACKET 7 EV-A-RL EVOLUTION LIGHT REPAIR ASSEMBLY OPTIONAL LIGHT FIXTURE COMPONENTS 7A EV-R-LENS EVOLUTION CLEAR LENS FOR LIGHT 7B EV-R-GASKET EVOLUTION LIGHT GASKET 7C EV6-R-BLB-BLU BLUE LED LAMP 7C EV6-R-BLB-WHC COOL WHITE LED LAMP 7C EV6-R-BLB-WHW WARM WHITE LED LAMP 7C EV6-R-BLB-YEL YELLOW LED LAMP 7C EV6-R-BLB-GRE GREEN LED LAMP 7C EV6-R-BLB-RED RED LED LAMP K H I J 0 7A 7B 7 6 7C A B C 5 7

5 = INCLUDED WITH LIGHT SET STAND LEGS ASSEMBLED MINIMUM WATER DEPTH STAND LEGS ASSEMBLED MAXIMUM WATER DEPTH MOUNT HOLE 7 MOUNT PATTERN MOUNT HOLE 6 MOUNT PATTERN STATIONARY ITEM NO. PART NUMBER DESCRIPTION QTY 0BH-0.5X0.6 HHCS.5-0x.65 - S. 0WF-0.5 FLAT WASHER.5 - S 0WL-0.5 LOCK WASHER.5 - S. EV-S-FOOT FOOT EVOLUTION STAND 0-7 INC 5 EV-S-LB U-BRACKET W / MOUNT HOLE EVO STAND 6 EV-S-LEG LEG EVO STAND 0-7 INC 7 EV-S-RING CENTER RING EVO STAND 0NH-0.5-0 HEX NUT.5 -- 0 S.S. - EVOLUTION SERIES ASSEMBLY INSTRUCTIONS

EVOLUTION SERIES FOUNTAIN TROUBLESHOOTING GUIDE Trouble Check Possible solutions Foutain does not work or starts then stops Not plugged in Cord must be plugged into a -wire outlet that is protected by a Ground Fault Circuit Interrupter (GFCI) or the supplied motor control box. GFCI tripped Reset GFCI. If GFCI will not reset or trips immediately, unplug pump and lights and reset GFCI. If GFCI will not reset, there may be a problem with the mtor control box or the incoming power. If the GFCI resets, plug the pump in to the motor control box. If the GFCI trips, there may be a problem with the pump cord. If the GFCI holds, plug into the optional lights. If the GFCI trips, there may be a problem with the lights. Contact Aqua Control Technical Support to troubleshoot lights or pump. GFCI not tripped, not running Disconnect power. Check propeller for obstruction. These motors have internal overloads. If the propeller is jammed, the internal overload may trip. This overload may require up to 0 minutes to cool down and reset. If the motor does not restart, there may be other motor problems. Contact Aqua Control Technical Support to troubleshoot the pump. Fountain spray pattern is smaller Fountain intake clogged Disconnect power, check suction screen for obstruction and remove debris. Nozzle clogged Disconnect power, remove nozzle and check for obstruction and remove debris. CONVERTING YOUR EVOLUTION SERIES FOUNTAIN TO A TORRENT PATTERN STEP DISCONNECT UNIT FROM POWER. STEP REMOVE PROP WASHER, PROP BOLT & LOCK WASHER. PROP BOLT LOCK WASHER PROP WASHER STEP REINSTALL PROP BOLT & LOCK WASHER WITHOUT PROP WASHER& TIGHTEN 9

AQUA CONTROL Evolution Series Fountain Limited Warranty Aqua Control, Inc. warrants to the original purchaser (end user) of any Evolution Series Fountain manufactured by Aqua Control, Inc. that any part thereof which proves to be defective in materials or workmanship, as determined by the factory within two years from the purchase date, will be repaired or replaced at no charge with a new or remanufactured part, and returned freight prepaid. The end user shall assume all the responsibility and expense for removal, packaging, and freight to ship to Aqua Control to determine the warranty claim and for all reinstallation expenses. The warranty is void in cases where damage results from: improper installation, operation with no flow, continued operation with only partial flow, continued operation with obstructions that result in pump cavitation (noisy operation), improper electrical connection, improper voltage, alteration, lightning, careless handling, misuse, abuse, freezing, disassembly of motor, or failure to follow maintenance or operating instructions. Modification or repair by an unauthorized repair facility will void the warranty. In no case will Aqua Control or its distributors accept responsibility for any costs incurred by the user during installation, removal, inspection, evaluation, repair, parts replacement, or for return freight. Nor will any liability be accepted for loss of use, loss of profits, loss of goodwill, for consequential damage, or for personal injuries to the purchaser or any person. In the event of problems believed to be covered under warranty, it will be necessary to notify the distributor who will try to help resolve the problem and who may contact the factory for additional assistance. If it is concluded that there may be a defect which may be covered under warranty, it will be necessary to get a Return Material Authorization (RMA) from the distributor before shipment. Freight collect shipments will not be accepted by the factory on warranties or repairs. The product or part(s) must be returned freight prepaid, to the factory, as directed, and in its original packaging or in a container which will prevent damage. Parts returned under warranty and damaged during shipping will not be covered under warranty for the shipping damage. If the factory evaluation of the returned goods concludes that the failure is due to defects in materials or workmanship, the part or parts in question will be replaced under warranty with new parts, remanufactured parts, or will be repaired at the factory s option. The warranty period for all parts supplied under warranty will terminate at the end of the original product s warranty. All warranty shipments from the factory will be shipped freight prepaid. Warranty registration is HIGHLY recommended. No implied warranties of any kind are made by Aqua Control, Inc. for its products, and no other warranties, whether expressed or implied, including implied warranties of merchantability and fitness for a particular purpose, shall apply. Should an Aqua Control product prove to be defective in materials or workmanship, the retail purchaser s sole remedy shall be repair or replacement of the product as expressly provided above. Aqua Control, Inc. 6A Wolfer Industrial Dr. Spring Valley, IL 66 Phone 00-77-009 FAX 5-66-90 0