SIGNETMARINE. Livewell Bait Pump Alarm. No Dead Bait.

Similar documents
MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

Installation Operation Parts

COOKSON OWNER S MANUAL

I Button Chemical Dispenser. Overview. Installation Instructions

Optima ETF-600/ETF-610

ONBOARD AIR HOOKUP KIT

SUNROOF - SERVICE INFORMATION ADJUSTMENTS

ELECTRICAL. Contents - Wiring Diagrams

Stay-IN-Play with Panic Stop Braking

03-04 Mach 1. Hellion Power Systems Mach 1 Kit Instructions

INSTALLATION INSTRUCTIONS:

Z TECHNICAL INSTRUCTIONS

INSTALLATION INSTRUCTIONS

General Information. Notations and Conventions. Compatibility Check. Kit Description. Call-Outs. Part Lists Great Plains Manufacturing, Inc.

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

INSTALLATION INSTRUCTIONS

Maintenance Information

MODEL ELC-12/40-CVM-D BATTERY CHARGER

Alliance Towel Dispensing System. Operation Manual

Quarter Master Series 94 Actuator

Tire pressure monitoring system

INSTALLATION INSTRUCTIONS:

Installation Instructions

GENERAL REQUIREMENTS:

User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring

Operating Manual. Hydra S (W)VAC

Service Manual Air Plus Second Stage

HEAVY DUTY ONBOARD AIR SYSTEM PART NO

MF 9690, 9790, Challenger 660, 670

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

COMPONENT ACCESS. If no voltage is present, check wiring to the board. If voltage is present, and brewer does not power on, replace board.

Breezair TBA 550 Installation Manual

Revised 10/23/2015 Page 2 of 10

PFadvantage JD 3300/4400/6600/7700; 4420

Troubleshooting Guide: 255 LED Light

RK Standby Battery Operator s Manual

665 Series Dispenser. Metering tip kit

Smart Wi-Fi Sprinkler Timer and Flow Meters

Master Power Brakes Electric Vacuum Pump Kit Various Applications P/N: AC9001K

Instruction Manual. Computer Controlled A/C - D/C Sump Pump System

INSTALLATION GUIDES OUTDOOR LIVING

The Mark V Air/Fuel Controller - Technical Manual -

NOTE. Installation and Service Manual Dual Planetary Gearmotor Slim Rack Slide Out System

Installation Instructions - ECS Tuning Vent Pod Vacuum/Boost Gauge Kit

P-600. Technical Manual. Troubleshooting Repairs Replacements

PumpAgents.com - Click here for Pricing/Ordering Fuse Size (A) Open Flow GPM (LPM)

COOKSON OWNER'S MANUAL

3.1 DISPENSER BLACK SHADOW SERIES. Tools Needed for Mounting SCS Dispenser Hammer

Items # and #

Electronic Products ELECTRONIC MAINTENANCE

ASSA ABLOY. 7100SZ Series SafeZone External Sensor. Installation and Instruction Manual ASSA ABLOY. Patent Pending

Tri-Spark Ignition System Installation Triple Cylinder TRI-0001

Installation Notes for Asplundh Chipper Model- 1003ASP- (EPS) Kubota 3.3 L KIT DOC

INSTALLATION & OWNER S MANUAL

TS-E TURBO STEAM ELECTRIC COUNTERTOP CONVECTION STEAMER PARTS AND SERVICE MANUAL

Optima ETF-500. Hand Hygiene. Repair Parts and Maintenance Guide PARTS LIST ETF-500 FAUCET ETF-500. See page 157 for faucet cable extension cords.

FOR New Electric Kit and Remote Control Installation

LAWN SPRINKLER, IRRIGATION PUMP

PFadvantage Metalfor Araus 1360

Specifications. General

The 606T-2 unit is designed to be used as a spray or foam unit where up to two chemicals can be attached to the unit along with a clean water rinse.

GENERAL REQUIREMENTS:

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

TABLE OF CONTENTS INTRODUCTION.. 3. A/C Ducting Installation. Power Kit Installation (Batteries)...5 OPERATION MANUAL 7-8 TOOLS LIST..

Vehicle Rear Observation System With Integrated Parking Sensors

HEAVY DUTY ONBOARD AIR SYSTEM

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

IMPORTANT! Remote Control Instructions

CVO - with ipod Amp & Speaker Upgrade Install Instructions for Batwing Fairing

Series BFM Bulk Flow Monitor 1A FUSE RED LED RELAY. Part Number BFM-1 BFM-2 BFM-3 BFS-1

REARSENTRY TM BASE KIT ROSTRA OBSTACLE SENSING SYSTEM CONTENTS

MEDIUM DUTY ONBOARD AIR SYSTEM

Installation Instructions

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

Flow Max. by Duraself. Flow Max by Duraself. Fluid Pump. Installation and Owner s Manual (For Aftermarket Applications)

INSTALLATION INSTRUCTIONS FUEL SURGE TANK KIT

Dual Trumpet Air Horn & Installation Instructions

Tools Needed for Mounting Cleá Filling Station

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

DODGE RAM 2500

INSTALLATION INSTRUCTIONS DOCUMENT REVISION : /17/2014

REVISED ATM72 Auto Transfer Module

Dual Trumpet Mini Air Horn & Installation Instructions

s4.5mp s4.5 MP System Owner s Manual Architects and custom home builders Everything you need to know.

Pump Gas Instructions for Polaris And 800 Models. Important Information before Installing This System:

ARC4000e 4 wheel compressor system w / 4 way Ride Pro controller

Table of Contents. Timer Identification Timer ID BLU-U Features: 1K 6K BLU-U Features 1K 6K

Centrifugal Constant Pressure Control

Amp & Speaker Upgrade Install Instructions for Batwing Fairing

ARC4800L Big Red Compressor System

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

23200 Navigator Dilution Control System 4 Button Model (NAV 4)

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Service Manual Air Tech Second Stage

Auto-Level Troubleshooting (Old Platform) Electronic Control- Prior to 2009, Pressure Switch Control panel #s 2057, 2058, 2795, 2795B

Power Distribution System User s Manual. Model: PDS-100

TurfDefender Electronic Leak Detector Kit Reelmaster 5000, 6000 and 5010 Series Traction Units

Installation and Operation Guide. Tundra HD 2500 Power Inverter. for the. Webasto BlueCool Truck System

Quarter Master Chief Series 92 Actuator

350 S. St. Charles St. Jasper, In Ph Fax

Transcription:

B A I T WAT C H SIGNETMARINE Livewell Bait Pump Alarm No Dead Bait. The SIGNETMARINE BaitWatch System alerts you to a livewell pump problem before your fishing trip turns into one. The loud alarm and dual-color status light immediately let you know if there is a pump malfunction or insufficient water flowing to your tank.

SIGNETMARINE BAITWATCH Livewell Bait Pump Alarm Instruction Manual SIGNETMARINE 2315 1/2 Artesia Blvd. Redondo Beach, California 90278 (310) 320-4349 (310) 320-5026 Fax www.signetmarine.

Table of Contents 1. Description... 2. Installation Clearance... 3. Necessary Tools and Items... 4. Installation of Housing... 5. Plumbing... 6. Electronics Module Location... 7. Display Panel with LED Installation... 8. Electronics Module Wiring... 9. Module Power Hookup... 10. Module Mounting... 11. System Check... 12. Troubleshooting... 13. Paddlewheel Sensor Cleaning... 14. Specifications... 15. Parts List... 16. Warranty... 1 1 1 2 2 2 3 3 4 6 6 7 8 9 9 10 ii

SIGNETMARINE B A I T WAT C H Livewell Bait Pump Alarm Instructions for Installation and Operation of the BaitWatch Alarm System. 1. Description The SignetMarine BaitWatch Livewell Bait Pump Alarm System is composed of 3 main components: the Flow Sensor Unit with integrated paddlewheel sensor, the Electronics Module with audible alarm, and the Indicator Panel with its bi-color LED status light. The BaitWatch Alarm System provides reliable, continuous monitoring of the flow of water to a livewell. It is ideal for monitoring bait tanks and mackerel or tuna tubes. The system detects water blockage, low flow, pump malfunction or electrical failure to the pump. 2. Installation Clearance 6.5 The sensor housing measures 6.5 H x 8 L x 2.5 W. An additional 3.5 of vertical clearance is needed to extract the paddlewheel sensor. 8 3. Necessary Tools and Items 1. 2. 3. 4. 5. 6. 7. Small 1/8 inch flat bladed screwdriver Small Phillips screwdriver Drill with 1/4 inch drill bit Contact cement or silicon glue 2 Stainless Steel hose clamps (not provided) Power switch and 1 amp fuse + fuse holder (not provided) Bait pump with 250 gal/hr actual flow to tank. 1

4. Installation of BaitWatch PVC Sensor Housing The Sensor Housing with its integrated paddlewheel sensor is completely waterproof and can be mounted anywhere between the pump and livewell. The supplied 25 foot cable can be extended up to 100 feet. If splicing the cable, the bare shield wire must be spliced as well. The unit can be mounted either vertically, with the water flowing upward, or horizontally. Since the sensor is bidirectional, it can measure water flowing through it from either direction. Do not tilt the sensor more than 45 degrees if mounted horizontally. Avoid mounting upside-down to prevent clogging by debris. 5. Plumbing The sensor housing is supplied with two, 1 hose insert fittings. Different size hose can also be used by replacing the screw in fittings. The sensor should be installed between the pump and bait tank. Do not use any lubricant on the barbs or inside the hose. If it is a tight fit, use water. Install stainless steel hose clamps (not included) around the hose and tighten securely. 6. Electronics Module Mounting Location Find a suitable location but do not mount the Module yet. Run the sensor cable back to where you want the Electronics Module to be located. The Module with its audible alarm can be mounted in any protected location. Mounting it behind or near a dashboard is ideal. Keep it protected from spray, rain or dew. The location should allow the alarm to be heard over the sound of your engine. Test-connect the module to 12vdc (see page 3) without the sensor attached, in your desired location, to verify the loudness of the alarm. The standard mounting recommendation is to place 2 rubber grommets beneath the flanges to allow a ¼ gap for the sound to be heard. 2

7. Display Panel with LED Installation Find a suitable location for the BaitWatch Indicator Panel. It is best installed with a little silicon glue, contact cement or similar. Try to find a location out of direct spray or dew. The LED status light s 14 leads can be extended if needed. 1. Drill the hole in your mounting location with a ¼ drill bit. 2. Feed the LED wires through your drilled hole. 3. Glue Indicator Panel with the LED to the surface. 8. Electronics Module Wiring Install the 3 wires from the flow sensor cable and the 2 LED wires to the Module terminal blocks according to the diagram below. The bare shield wire in the sensor cable must be connected to terminal 6. Insert the wires into the slots and tighten the screws on the opposite side. It helps to slightly bend the wires before inserting them in the terminals. Do not connect the module to 12 volts just yet. If the power is connected to it without water flowing through the sensor, the alarm will sound. Option: The white jumper wire in the module can be connected to terminal 1 to have the alarm trigger at a 50% higher flow rate than the default setting. This allows the sensor to alert you to a developing flow problem. After all the wires have been connected, apply a small amount of anti-corrosion spray to the contacts. 12VDC - 12VDC + Jumper wire LED red wire 1 2 3 LED black wire 4 Sensor red wire Sensor bare wire 5 6 Sensor black wire 7 3

9. Module Power Hookup It is recommended to install a separate power switch (with a 1 amp fuse) for the BaitWatch Module. This will allow you to turn off the alarm independently of the pump. There are two methods of providing power to the Module. For a fail-safe installation it is recommended to wire the Module as outlined in figure 1. Figure 1. Wiring the Module with a power switch independent of the pump circuit. Benefit: The alarm will sound from any pump malfunction including a power outage to the pump or a water blockage. Drawback: You have to remember to turn the Module on when you turn on the bait pump. Module New switch for Module Pump Fuse Fuse + - 12 VDC 4

Figure 2. Wiring the Module with its power switch in line with your pump switch. Benefit: One switch turns both the pump and sensor on at the whole time. Drawback: If the power fails to the pump or its fuse blows, the alarm will not alert you because it won t have power either. Module New switch for Module Fuse Pump Existing pump switch Fuse + - 12 VDC After the switch is installed, turn it off and connect the power wires to the module on terminal 1 and 2 as shown in the diagram on page 3. 5

10. Module Mounting Mount the Module flange-side down with 2 rubber grommets beneath the flanges to provide a gap so that the alarm can be heard. If mounting the Module on a ceiling, mount it with the top in contact with the ceiling (flange side down) and use longer screws or bolts to attach it. Do not mount the Module with the open side facing up on a ceiling if there is any chance of moisture getting into the unit. Be sure that the wires leading out of the Module are secured with zip-ties and can t be inadvertently yanked loose. 11. System Check 1. Turn on your bait pump. Check for possible leaks at the Sensor and around the fittings. 2. Apply power to the BaitWatch Module. The status LED light on the indicator panel should shine a steady green. The alarm should be silent. 3. Turn off your bait pump. You should hear the alarm and the green light will turn red on the indicator panel. 4. Turn your bait pump back on. The alarm should shut off and the red light turn back to green. You can also try kinking the hose near your bait tank and note the flow rate when the alarm is activated. The electronics measure the voltage generated from the self-powered paddlewheel transducer. The faster the rotor spins, the higher the voltage it generates. The alarm trigger point is set at approximately 80 gal/hr. (120 with the white jumper wire attached) with a reset point at approximately 180 gal/hr. There is also a programmed short time delay between sensing the low voltage (low flow) and triggering the alarm. The reset point is set higher to ensure that the alarm does not cycle on and off. 6

12. Troubleshooting SYMPTOM CAUSES REMEDIES LED on Panel not lit. No alarm when flow is stopped. Audible alarm works but LED does not light up. Module not getting power. Wires not securely fastened. Module not wired correctly. LED wires not securely fastened. Dead LED. Check wiring and voltage to Module. Check wiring to LEDs. Disconnet LED leads and test by connecting leads briefly to 3vdc. Switching leads should switch red to green. Replace LED. Alarm sounds and Panel Light is Rotor jamb in housing or Clear rotor or disconnect white red but water is still flowing OK to white wire is connected to terminal wire from terminal 1 in Module. the bait tank. 1 in Module. 2. Verify there is AC voltage 2. Malfunctioning paddlwheel sensor generated from sensor output with voltmeter > 1VAC. Alarm not very loud. Module mounted incorrectly. Increase gap between Module and mounting surface. 7

13. Paddlewheel Sensor Cleaning The paddlewheel sensor can be extracted from the Sensor Housing to be cleaned if necessary. To inspect the paddlewheel rotor follow the steps below: 1. Shut off the thru-hull water inlet valve to your bait pump. 2. Make accommodations for possible back-flow from the bait tank when the sensor is removed. 2. Unscrew the top red cap on the sensor housing until it is no longer engaged in the threads. 3. Unscrew the bottom red ring to press out the top red cap and sensor. 4. Pull out the sensor with the wire bail. 5. Inspect and clean the rotor and housing. Do not apply any lubricant on the rotor pin or the rotor. Re-install the sensor in the reverse order above, lubricating the O-rings with silicon grease. Be sure that the tabs in the top of the sensor line up with the notches in the sensor housing. The sensor can be installed in either direction so long as the tabs and notches line up and the paddlewheel rotor shaft is perpendicular to the flow of water. Tighten the red cap by hand. Do not use tools. 8

14. Specifications Bait Pump Recommendations: Min. Flow Rate Requirement: Alarm Trigger Point: Alarm Reset Point: Alarm Trigger Point 2: Buzzer: Supplied Hose Fitting: Hose Size Range: BaitWatch Housing: Electronics Module: Cable Length: Cable Type: Fuse Recommendation: Power Requirements: Shipping Weight Complete: 500 to 1100 gal/hr. (4000 gph modified) 250 gal/hr. actual flow to tank Approx. 80 gal/hr. Approx. 180 gal/hr. Approx. 120 gal/hr. Stainless Steel Diaphragm. 103db 1 inch 1/2 to 1-1/4 in. (with optional fittings) Schedule 80 PVC ABS (Polyurethane Encapsulated PCB) 25 feet supplied. 100 feet max. 2 conductor 22AWG shielded 1 Amp 12VDC 30mA standby 3 lbs. 15. Parts List M1531 Rotor Repair Kit. 1-2200.100-3 Paddlewheel Sensor with cable M1556-1 PVC Housing Tee with Core (standard) M1556 PVC Housing for > 1100 GPH pump 1-3501-E BaitWatch Electronics Module 1-3501.512 Display Panel 6810-0005 LED (Red/Green) Contact the factory for sensor housings designed for high output pumps. Larger housings available. 9