Instructions EM 101 Low Flow Electromagnetic Flow Meters

Similar documents
EM 101 EM EM EM GENERAL INFORMATION. SPECIFICATIONS MATERIALS Wetted Materials - FLOW RANGE

EM101 LOW FLOW MAGNETIC FLOWMETER INSTRUCTIONS

RCM - Direct Reading Flowmeters

Appendix. Clearance. Skewed profiles. Application Schematics

PE202. Low Flow Magmeter Instructions. Precision Flow Measurement An ONICON Brand PROUDLY MADE IN THE USA

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

PMG MAGNETIC FLOWMETER

Distributed by: M&M Control Service, Inc MICRO-FLO MICRO-FLO

F-2700 SERIES INSERTION VORTEX FLOW METER

Hydro-Flow Model 3100

F-1500 SERIES INSERTION TURBINE FLOW METER

DPT TARGET TYPE FLOWMETERS

ISTEC MAGNETIC METERS

WMX-series MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS

FPI Mag FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODELS 394L AND 395L MAG METER SUBMITTAL

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

M3500 Industrial Pressure Transmitter

Model DFX Doppler ultrasonic flow meter

The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been

Lower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS).

CONTROLLERS & SPECIAL VALVES

Ultra Mag SUBMITTAL PACKAGE

TX800-Series FLOW SENSOR INSTRUCTIONS. TX81x TX82x 9 001:2008 ISO CERTIFIED COMPANY TX800-SERIES FLOW SENSOR INSTRUCTIONS

imag 4700 SERIES FLANGED MAGMETER

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

Electromagnetic Flowmeters. Product Overview.

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter

Flow Meters & Instruments. Insertion Paddle Wheel & Magnetic Flow Meters Flow & Anaytical Instruments. Technical Catalogue

EX80-Series ELECTROMAGNETIC FLOW SENSOR INSTRUCTIONS EX81 EX82 EX :2008 ISO CERTIFIED COMPANY

Compu-Flow. Electromagnetic Insertion Flow Meter. Compu-Flow EXM MAG

Rosemount 8750WB Magnetic Flowmeter System

F-2700 SERIES INSERTION VORTEX FLOW METER

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

MICRO-FLO MICRO-FLO. Digital Paddlewheel Flow meter Operating Manual. Blue-White. Industries, Ltd.

RESISTIVITY MONITOR/CONTROLLERS

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

FPI-X FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODEL 395X MAG METER SUBMITTAL

EX80 Series EX81 EX82. E X 8 0 S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s. The Leader in Flow Meter Value.

WMP-Series PLASTIC-BODIED MAGMETER INSTRUCTIONS 9001:2008 ISO CERTIFIED COMPANY WMP-SERIES PLASTIC-BODIED MAGMETER INSTRUCTIONS. 3 inch.

FT430/440/450 RATE/TOTAL INDICATOR INSTRUCTIONS

F-2600 SERIES INLINE VORTEX FLOW METER

Hydro-Flow Model 2200 Installation and Operation Guide B

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

Magnetic Inductive Flowmeter EP / UMF2 (B)

ARCHIVED. EX80 Series. (Includes Dates 6/28/05 to 10/06) EX81 EX82

Product Guide: Series III Pump Control Board Set (RoHS)

DW PADDLE-BELLOWS FLOWMETER & SWITCH

F-2000 MODEL RT INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

MFM220 & MFM220DC Plastic-Bodied Magmeter

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display

Electromagnetic Flow Monitor magphant

2100 Turbine Flow Sensor

Flow meter Type Recordall (RCDL)

UFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater

SSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview

TX 115/215 Hot-tap Insertion Turbine Instructions

DW PADDLE-BELLOWS FLOWMETER & SWITCH

Model Q45H/ Residual Chlorine Monitor...

The information in this chapter will enable you to: 90VAC to 50/60 Hz

Operations Manual. Zero Speed Switch Sensor Model ZS09P

DPS280 / DVS280 Series

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

Signet Pressure Transmitter

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

MICRO-FLO MICRO-FLO. Digital Paddlewheel Flow meter Operating Manual. Blue-White. Industries, Ltd.

SeaMetrics Flow Meters and Flow Computers

Temperature Controllers

DUST ALERT BinMaster Price Book binmaster.com Subject to change without notice 1

EX100/200-Series INSERTION MAGNETIC FLOW METER INSTRUCTIONS EX110 EX210 EX150 EX :2008 ISO CERTIFIED COMPANY

Iron Gate Air Pump System Manual

DW PADDLE-BELLOWS FLOWMETER & SWITCH

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters

Full Profile Insertion

G2 Industrial Grade Meters

Signet 2551 Magmeter Flow Sensor

VARNA Products 15 GPM (57 LPM) Prelube Kit for MTU 4000 Series Marine Engines

RVS-DN Digital Reduced Voltage Motor Starter

TX80-Series FLOW SENSOR INSTRUCTIONS TX81 TX :2008 ISO CERTIFIED COMPANY TX80-SERIES FLOW SENSOR INSTRUCTIONS

SR50 Series Pressure Regulating (Reducing) Valves

LN3 Series Motor and Drives

Phoenix Inverter

Dissolved Oxygen Measurement System with Air Blast Cleaner

Paddle-wheel flow controller for On/Off control

TURBINE METERS - WP Series

Versa II SLR Lubricator

Speed Sensor. Inputs: Safety Information. Outputs. Wiring Diagram. Electrical Data: NOTICE

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

Distributed by: M&M Control Service, Inc

LNII Series Motor and Drives

RVS-DX Digital Reduced Voltage Motor Starter

EVP SERIES PROPORTIONAL CONTROL VALVES

Electromagnetic flowmeter EMKO E

Series 10-ZSE40A(F)/10-ISE40A

Temperature Controllers

ProMinent delta Solenoid Diaphragm Metering Pumps

SERIES FLMG MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS

Transcription:

PDF Published June 3, 2004 Instructions EM 101 Low Flow Electromagnetic Flow Meters Installation Mounting The EM 101 model has a flow meter unit and a separate control unit containing a LCD display. The control unit should be mounted to a secure surface with screws or bolts. To gain access to the mounting holes, remove the front cover. The mounting holes are directly under the front cover screws. The flow meter unit is supplied with a removable mounting bracket, which can be attached to a panel or solid surface. If piping is rigid and is not subject to vibration, the meter may be supported by the piping and the mounting bracket removed. The flow meter may be connected to metal or plastic pipe or tubing. The -025 (1/4" ID) and -038 (3/8" ID) meters have 3/8" male NPT connections. The -050 (1/2" ID) has 1/2" male NPT connections. For plastic tubing use female NPT x tubing adapters. A minimum 1" of straight pipe run is recommended on the inlet side of the meter. Straight run on the outlet is not necessary. CAUTION: Although this meter has an empty pipe detection function, under certain conditions of empty or partially-full pipe the meter may read a flow when there is none. Always mount the meter in such a way that it will always be full of liquid. Connections The unit is supplied with two cables pre-wired between the flow meter and control units. One is for power to the flow meter coil and the other is the flow meter output signal from the electrodes. All customer wiring connections (power, output signals and alarm relays) are made in the control unit. A standard power cord is normally used for the power connection. If conduit connection is required, the strain relief fitting may be replaced with a conduit connector. Grounding For proper operation and optimum metering accuracy one or both of the grounding lugs on the flow meter unit must be well connected to a good quality earth ground. The grounding lugs also retain the mounting bracket. All flow meter units are supplied with 12 feet of grounding wire attached. When metallic piping is attached to the flow meter, an additional ground connection clamped to the piping should be made. See the diagram on page 3. Operation Display The flow rate is displayed in the time and volume units which have been selected during the setting procedure. The flow rate is displayed up to 4 digits. The total flow is displayed in the same units of up to 8 digits. It then re-sets to zero and beings again. Output The analog output, either 4 20 ma or 0 to 5 VDC, varies continuously with the flow. If the output is too "jumpy" (changes too frequently), it can be dampened by either increasing the average time (see the " Fast Analog Output" setting) or by selecting "Disabled" under Fast Analog Output and increasing the amount of dampening using the Low Pass Filter setting. The pulse output will produce a 50% duty cycle pulse at the volume intervals for which it is set - one pulse per liter, for example. Note that since each pulse consists of equal times on and off, if the interval between pulses is large the pulse may remain in the on condition for several seconds. The relay alarm output will only energize if the flow goes above (high) or below (low) the flow alarm setting. The alarm relay will remain energized until the flow exceeds the setpoint by.25% (hysteresis). Start-up On start up it can take from a few seconds to a minute for the signal to stabilize. Keeping the meter filled with fluid will minimize this delay. EM101 Instructions 1

Dimensions Control Unit 4.93" 2.92" 115 VAC Power Cord - Included but not shown 0.71" 0.59" Customer Cabling for Outputs, Alarms Sensor Cables (2) Backlit LCD, 2 Lines of 16 Characters Keypad with tactile Switches 4.93" 1.25" 1.25" 1.25" 1.00" Captive Plastic Cover Screws (4) Flow Meter Unit L = 3.75 " PVDF Male Threaded Connection Fittings (2) 3.75" 3.00" 2.50" 6 ft. Long Cables to Control Unit for Power and Signal 0.218 Dia., 4 Holes 3.00" 3.50" 4.40" Removable Mounting Bracket 2.30" 12 ft. Long Grounding Wire with Lugs - Supplied 2 EM101 Instructions

Grounding Standard Grounding with Thermoplastic Piping Grounding with Metallic Piping Electrical Connections Control Unit Housing Control Unit Display Board opto isolated, passive, isolation volatage 500V Plug In for Display Cable W G B R WHITE GREEN BLACK RED To Flow Meter Unit EM101 Instructions 3

Setting Procedure DISPLAYS TING EM101 This is the power-up display. Wait 2 seconds Rate Tot Rate/total display appears two seconds after power-up. Press to begin programming. Volume Units G Use the key to choose the volume unit: milliliters (ml) liters (L) or gallons (G). Time Units M Use the per day (D). key to choose the time base for rate: per second (S) per minute (M) per hour (H) Tot Dec Point Formal 0.0 Use the key to choose number of decimal places: 0, 0.0, 0.00. An.Output Type Fast An.Output Rate for Analog Output: Leave Analog Output Type unchanged unless you intend to use the 0-5 V output. Standard setting is for 4 20 ma. Consult Chemline for 0-5 V output. Leave Fast Analog Output unchanged unless you have a demanding closed loop application. Standard setting is disabled. If you enable this output, use the key to select a response time, 50 to 1000 millisecond. This will control how rapidly the analog output tracks flow. Use the and key to set the percentage of full scale at which peak analog output (20 ma or 5 V) occurs. For example, on the max 1 USGPM meter, 60% would equal 0.6 USGPM. Rate for High Alarm: Rate for Low Alarm: Pulse Output Low Pass Digital Filter: Totalizer Reset EM101 4 EM101 Instructions Use the and key to set the percent of full scale at which the high flow alarm will energize. For example, on the max 1 USGPM meter, 90% would equal 0.9 USGPM. Use the and key to set the percent of full scale at which the low flow alarm will energize. For example, on the max 1 USGPM meter, 10% would equal 0.1 USGPM. Use the and key to set the number of pulses (0000 to 9999) per unit. If you have selected liters, it will be pulses per liter, etc. This setting controls the smooth/responsive trade off of the display. Increasing the time makes the display smoother, but slower to respond to change. Use the to set. If using the meter with pulsing flows, it may be necessary to increase the time. Choice: 1, 2, 5, 10, 20 seconds. Use the key if it you wish to enable the totalizer reset. It will switch between Enabled and Disabled. If the reset is enabled, every time the key is pressed (during normal operation) the totalizer will reset to zero. Settings are completed. Wait five seconds to return to normal operations.

Specifications MATERIALS Flow Tube: PVDF Electrodes: Platinum coated Titanium O-Ring Seal: EPDM or Viton Housing: Flow Meter: Aluminum coated with heat fused acrylic enamel Control Unit: Polycarbonate POWER SUPPLY 115 VAC, 60 Hz, optional 220 VAC/50Hz ACCURACY ± 1% of reading above 10% of full scale ± 3% of reading below 10% of full scale OUTPUTS 4 20 ma or 0 5 VDC, both opto isolated, passive (500 Volt isolation) Frequency to 9999 pulses per gallon, opto isolated, open collector NPN, max. 10 mh inductance, 30 VDC LCD backlit display with 16 characters, 4 digits flow rate, 8 digits total flow High and low flow alarm relays, isolated, rated 100 ma at 110 Volts FLUID MEDIA Maximum Temperature: 85 o C (185 o F) Maximum Pressure: 150 psi at 20 o C Minimum Conductivity: 20 microsiemens per cm Trouble Shooting Problem No Display. Flow rate always reads 0. Flow rate incorrect. Possible Causes No power. Blown fuse. Loose ribbon cable. Reversed flow direction. Missing ground wire. Empty pipe. Flow rate below minimum. Loose wiring or incorrect wiring. Fluid conductivity <20 us/cm. Missing or incorrect ground wire. Fluid conductivity <20 us/cm. Empty pipe. Possible Solutions Check for 110 VAC. Test fuse, replace if blown. Check ribbon cable connections. Reverse flow connections. Install ground wire. See page 1. Install meter in vertical position. Use next smaller flow meter. Check connections on display board. Select another flow meter. Consult Chemline. Check for proper grounding. See page 1. Select another flow meter. Consult Chemline. Install meter in vertical position. 55 Guardsman Road, Thornhill, Ontario, Canada, L3T 6L2 Tel: 905-889-7890 info@chemline.com Fax: 905-889-8553 www.chemline.com Your Pipeline To Quality Valves, Piping, Flow Meters and Controls EM101 Instructions 5 Established in 1968