KVM KVM. Capture Jet Hybrid Backshelf Hood. Capture Jet TM Hybrid Backshelf Hood

Similar documents
KVL-P with Plate Shelf

KVR Capture Jet. KVR- Capture Jet Round Island Hood with Perimeter Jets. Round Island Hood with Perimeter Jets

Model ND-2 Specification

KVI Kitchen Canopy With Capture Air

KWF Water Wash Canopy with Supply Air

KWT GALLEY WATER WASH HOOD GALLEY WATER WASH HOOD KWT. With supply air and Capture Jet technology

Operators Manual for JES-HD

Halton - Advanced Air Purification, Now with ELF Extended Life Filters!

Installation Manual for Ecology

Installation, Operation and Maintenance Manual

Filter Hood Model CA-S

HOOD ACCESSORIES HOOD ACCESSORIES HOOD ACCESSORIES

KVI - Capture Jet hood with Side-Jet Technology KVI. Capture Jet Hood with Side-Jet Technology

Operators Manual. Manual provides Installation and Operating Instructions. Model MM1 Series Hood

AIR ZONE INTERNATIONAL MIXED-FLOW AIR COLUMN UNIT

Operators Manual for M.A.R.V.E.L.

Operators Manual for Capture Ray (UV)

Direct Gas-Fired Heating

ExtractAire. Grease Filters for Commercial Kitchen Ventilation Hoods. Baffle. High Velocity Cartridge (HVC)

ENVIRO UNIT CES SERIES

Electrical Control Panel

Kitchen Ventilation Systems. Exhaust Hoods & Grease Extraction Fire Suppression Systems Accessories

When Time Matters! listed Fire Damper

ULTRASUITE. Operating Room Diffuser System with Integrated LED Lighting

OPERATOR MANUAL IMPORTANT INFORMATION, KEEP FOR OPERATOR

Optimizing System Performance

DW Series - Exhaust Only Wall Canopy

Photographer: BRUCE T. MARTIN, LFD Laminar Flow Diffuser

SECTION AXIAL HVAC FANS

Tubular Centrifugal Fans

Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System

EXPERIMENTAL STUDY OF GREASE EMISSION FILTRATION FOR KITCHEN HOOD BY WATER MIST

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

Installation, Operation and Maintenance Manual

Commercial Kitchen Hoods Installation, Operation, and Maintenance Manual

Thirteen (13) UL listed fluorescent fixtures per booth will supply illumination.

Spring Air Systems FN-B-MB-10/4.5-VE Wall-Mounted Canopy Exhaust Hood Performance Report

EGG CRATE RETURN GRILLE

J L I e x h a u s t h o o d

WAC Air Curtains Technical Guide

The reference in sandblasting. DCM\DCM 3000 a DCM to series.

FN Fan-Coil Units High-Performance, Horizontal

Installation, Operation and Maintenance Manual

Filtered Kitchen Supply Packaged Ventilator

F. VAV hoods shall have a restricted bypass plate.

SDL Single-Duct, Low-Height, VAV Terminals

SECTION DUCTWORK ACCESSORIES

Operators Manual for EcoloAir TM

RERV & RERVX RERVLP. Rotary Energy Recovery Ventilators. Low Profile Indoor Rotary Energy Recovery Ventilators

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)

Inline Fans [ 14 ] * UL is optional and must be specified.

WhispAire Range Hood Quiet Hood

SECTION CENTRIFUGAL HVAC FANS

Requires Ductwork and Blower

Protector XStream Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

SPD SQUARE PLAQUE DIFFUSER

PennBarry Fan Guide Specification. Laboratory Exhaust System: Model vplume

Building Integrated Duct System

Commercial Kitchen Hoods Installation, Operation, and Maintenance Manual

CHAPTER III SYSTEM DESIGN

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

AIR-AIR ENERGY CONSERVATION MODULE

X-CYCLONE EVN-W Series

General Description. Product Specification. Document Digital Temperature Interlock

Air Boss M-Series Media & Adsorption Air Cleaner

NON PRESSURIZED, GALVANIZED PREP ROOM Model #ENCG C-PREP

Scope and Application of ASTM 1704, Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems

Modified Downdraft Paint Booth Nut and Bolt Assembly Pre-Punched Panel Flanges

Total comfort control

we make clean air Air Filtration Solutions Industrial Commercial Residential quatroair.com AIR TECHNOLOGIES INC.

Hoods for professional kitchens

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

Installation, Operation and Maintenance Manual

VAV TERMINAL UNITS. VVD VAV Diffusers

W-VI Series - Internal Make-up Air Wall Canopy

SECTION HVAC POWER VENTILATORS

Model FD-350. Static Rated Fire Dampers 3 Hour Fire Resistance Rating. Application. Ratings. Construction Standard Optional.

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Scope and Application of ASTM 1704, Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems

Automatic Roof Door Vents

TSS Single-Duct VAV Terminals

EXHAUST HOODS HNPD, HNPA, HPPD, HFPD, HNCD, HNCA, HPCD, HFCD, HKCD, HNPDC. Installation, Operation and Maintenance Manual

Fixed Range Exhaust Flow Canopies for NU 540 (Series 1 ), NU 543 (Series 1 ) Class II, Type A2, Biological Safety Cabinets

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404)

Energy Recovery Laboratory Exhaust

Installation, Operation, and Maintenance Manual. Automatic Fire Damper

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

READ AND SAVE THESE INSTRUCTIONS

Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD

A I R C O M P R E S S O R S R O L L A I R E

A. This Section includes natural gas piping, specialties, and accessories within the building.

WELDING FUME EXHAUSTERS & ARMS

Installation, Operation and Maintenance Manual

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

The Anatomy of a Drum Filter

Operators Manual for KVS

Element D Services Heating Ventilating and Air Conditioning ODG010107

Bulk Storage Systems. Clean Organized Safe Efficient Reliable

Transcription:

Capture Jet Hybrid Backshelf Hood The hybrid backshelf model of Capture Jet hood is a highly efficient kitchen ventilation hood that removes contaminated air and excess heat emitted by cooking equipment, helping to provide a comfortable and clean environment. The hood uses the advanced Halton Capture Jet technology to improve the capture and containment of the airflows generated by the cooking equipment. Overall exhaust airflow rates can be reduced up to 30% compared to traditional hood models. The Capture Jet technology is based on the high entrainment efficiency of a compact, high-velocity capture air jet. The capture air jets efficiently induce ambient air at the critical front face area of the hood, minimizing the spillage of the contaminated air and maintaining good air quality in the chef s work area. Improved indoor air quality with reduced energy use. Halton Capture Jet reduces the exhaust airflow rates required and improves the capture and containment efficiency of the hood. High efficiency grease filtration using UL and NSF classified Halton KSA multi-cyclone filters with a particulate extraction efficiency of 92% on particles with a diameter of 8 microns per ASTM F2519. T.A.B. (testing and balancing) ports, which allow accurate and effective commissioning. Horizontal front overhang is 0 with a minimum depth of 42 (1067mm) Standard LED light fixtures. Optional LED dimming is available for Capture Jet hoods. Dimming is control by a knob on the switch panel or through Halton HMI Touch Screen. Stainless steel, welded design. NOTE: Factory must be advised of any special requirements of the Authority Having Jurisdiction at time of quote. 1

9 2 6 1 Part Description 1 18 Ga. Stainless steel 2 Exhaust duct collar 3 Capture Jet air 4 Side Skirts 5 KSA grease filters 5 8 3 10 4 6 Integrated Capture Jet fan intake 7 Real Seal (optional) 8 Grease collection cup 9 Hanger bracket 7 Construction The hood combines Capture Jet TM technology, light fixtures, airflow measurement T.A.B. ports and KSA grease filters. The hood shall bear ETL or UL label. The ETL/UL listed range hood without exhaust fire damper per standard 710 and be fabricated in compliance with NFPA-96, and shall bear the NSF seal of approval. The exposed parts are manufactured from 18 ga. stainless steel. The hood ends have double side wall construction. A concealed collection cup is fitted into the grease drain channel for easy removal of the grease and dirt extracted by the KSA multi-cyclone filters. Dimensions Wall Model Inches Length 40...192 Width 42...72 (including 3 standoff) Height (rear height including side skirts) 58... 64 Modification/Options Switch Panel Rear Seal Fire Protection Backsplash LED Dimmable Lighting Ceiling Closure Panels Capture Jet Intake Location (Top) Powder Coating in a Variety of Colors Listed Exhaust Duct Balancing Damper Custom/Design Stainless Steel Exterior Textures and Finishes M.A.R.V.E.L. Demand Control w/ VFD by Halton 2

PLAN VIEW 3 (76) 39 MIN. (787) 5 (127) 40 MIN. TO 192 MAX. (1016 TO 4877) LEFT SECTION VIEW 39 MIN. (787) CAPTURE JET FAN 20 (508) FILTER 15 (381) 58 TO 64 (1473 TO 1626) SIDE SKIRT OPTIONAL REAR SEAL 3

Balancing of Capture Jet Hoods The capture jet and exhaust air flows are easily and accurately determined by measuring the pressure difference from the T.A.B. ports mounted in each plenum. Corresponding air flows can be read from the diagrams provided. All T.A.B. readings assume cold conditions. To adjust for an exhaust temperature of 110 ºF, multiply the readings by a factor of 0.93. - 2.5 Filters - 2 Filters 0.35 350 400 450 500 550 600 650 700 750 800 850 900 350 400 450 500 550 600 650 700 750-3 Filters 0.35 450 550 650 750 850 950 1050 1150 4

- 3.5 Filters - 4 Filters 500 650 800 950 1100 1250 550 650 750 850 950 1050 1150 1250 1350 1450-4.5 Filters - 5 Filters 700 800 900 1000 1100 1200 1300 1400 1500 800 900 1000 1100 1200 1300 1400 1500 1600 1700-5.5 Filters - 6 Filters 800 900 100011001200130014001500160017001800 850 1050 1250 1450 1650 1850 2050 5

- 6.5 Filters - 7 Filters 900 1100 1300 1500 1700 1900 2100 1100 1300 1500 1700 1900 2100 2300-7.5 Filters - 8 Filters 1100 1300 1500 1700 1900 2100 2300 2500 1200 1400 1600 1800 2000 2200 2400 2600 6

Suggested specifications General Kitchen hood inner liner shall be constructed from 18 gauge stainless steel where exposed. The kitchen hoods shall be supplied complete with outer casing /main body, inner liner, exhaust duct, pressure measurement T.A.B. ports, Outer casing panels shall be constructed of stainless steel with a brushed satin finish. Each joint shall be welded and liquid tight, avoiding harmful dripping of condensation. All exposed welds are ground and polished to the original finish of metal. Canopy ends shall be double sided wall construction (no single wall hoods permitted). Exhaust The exhaust airflow will be based on the convective heat generated by the appliances underneath each hood system. Submittals shall include convective heat calculations based on the input power of the appliance served. Capture Jet TM System The hood shall be designed with Capture Jet TM technology to reduce the exhaust airflow rate required, and to improve the capture and containment efficiency of the hood, while reducing energy consumption. The Capture Jet TM hood shall have an integral fan. The Capture Jet TM air shall be introduced through a special discharge panel and shall not exceed 10% of the calculated exhaust airflow. Slot or grille type discharge shall not be used. T.A.B. Ports The airflows through the extractors and the Capture Jet TM air chamber are to be determined through the integral T.A.B. (Testing and Balancing) ports mounted in the hood. The airflows are to be determined by the pressure vs. airflow curves supplied by Halton. Light Fixtures Hood lights shall be U.L. Listed LED fixtures, suitable for grease hoods. 20 Watts per fixture, 50 foot candles at cooking surface. The lighting shall be suitable for single phase power supply. Dimmable LED option is available. Standalone Hood based dimming control on the switch panel. When M.A.R.V.E.L. controls are used, all hoods connected to the system can have the light intensity adjusted through the HMI touch screen simultaneously. Control Panel The master electrical panel consisting of one starter per motor with overload protection can be supplied (optional). Control panel remote mounted. (For constant volume systems). M.A.R.V.E.L. controlled systems come with an HMI touch screen to monitor variable volume operation and incorporate the use of V.F.D. s to control fan operation. Grease Extractors The hood shall be equipped with KSA multi-cyclone stainless steel grease extractors. The KSA filters shall be NSF and UL classified. The particulate extraction efficiency is 70% on particles with a diameter of 5 microns and 98% on particles with a diameter of 15 microns per ASTM F2519. The pressure loss over the extractor shall not exceed 0.70 inches W.C. at flow rates approved by UL for heavy load cooking. Sound levels shall not exceed an NC rating of 55. Baffle or slot type extractors shall not be used. Fire Suppression System The kitchen hood fire extinguishing system shall protect the kitchen hood against grease fires by a completely automatic fire control system, which consists of wet chemical. The fire detection system shall be capable of detecting fire in the hood, duct, or surface equipment and shall automatically discharge liquid extinguishing agent into the plenum chamber, exhaust duct collar, and cooking appliance areas to ensure against re-ignition or re-flash. System components shall include a springloaded fusible link detector, wall mounted emergency pull stations, wall mounted automan and cabinet, and a mechanical gas valve installed in the gas line serving the cooking equipment. System installation shall be made by an authorized representative of the system manufacturer and conform to UL 300 requirements and local codes. Date: 02-2012 - Rev1 The company has a policy of continuous product development, therefore we reserve the right to modify design and specifications without notice. 7 For more information, please contact your nearest Halton agency. To find it: www.halton.com Halton Company 101 Industrial Drive Scottsville, KY 42164 USA Tel: 270-237-5600 Fax: 270-237-5700 Halton Indoor Climate Systems 1021 Brevik Place Mississauga, ON L4W 3R7, Canada Tel: 905-624-0301 Fax: 905-624-5547