Refrigerated incubator with Peltier technology

Similar documents
Heating oven with mechanical control

Heating chamber with mechanical convection

Heating oven with natural convection

Heating chamber with mechanical convection

Heating chamber with mechanical convection

Heating oven with mechanical convection

Heating chamber with mechanical convection

Climate chambers with illumination

Climate chamber with illumination

Drying ovens. ED 53 - Drying oven with natural convection. Performance features and equipment :

MKT 240 (E3) - Environmental simulation chamber for complex temperature profiles in the low temperature range

Safety drying ovens. Advantages: Areas of application: FDL series 115

Safety drying ovens with expanded temperature range

Safety drying oven with expended temperature range

Drying ovens. ED Drying oven with natural convection. Performance features and equipment :

Drying ovens. FD 53 - Drying oven with forced convection. Performance features and equipment :

Model ED 720 Drying and heating chambers Classic.Line with natural convection

Model ED 400 Drying and heating chambers Classic.Line with natural convection

Model ED 400 Drying and heating chambers Classic.Line with natural convection

geass.com Environmental simulation chambers for cyclic temperature testing MK MKT series Alternating temperature and climate testing

MDL series Safety drying ovens with first class safety features and an expanded temperature range

MK MKF MKT MKFT Environmental simulation chambers

Environmental simulation chambers MK MKF MKT MKFT

Dynamic climate chambers. MK MKF MKT MKFT series

Cooled incubators (ST), laboratory refrigerators

INCUBATORS I PAGE 4-8. COMPRESSOR-COOLED INCUBATORS ICPeco PAGE COMPRESSOR-COOLED INCUBATORS ICP PAGE 19-20

Incubators. Incubators

C:\Users\Steen Lauritzen\Dropbox\CTS - Citrotek\English quotation text\pharma\cp+10_1200 eng.doc

FUNCTION LINE HEATING AND DRYING OVENS

Water Baths & Shaking Water Baths. Quality Technology for Routine Applications

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

Digital incubating/ refrigerating benchtop shakers.

Compression/Tension Testing Machines

Laboratory refrigerators

Callisto 100. Cold Filter Plugging Point Tester

Instruments for the Analysis of Petroleum Products. Oxidation Stability

Envair Lab SCS Evo Comfort+ Class II Microbiological Safety Cabinets

Boekel Complete Culture Control Incubators

Flash Point Process Analyzer

TECHNICAL CHARACTERISTICS: Structure : upright type, realized in sheet steel epoxy coated white colour both in- and outside or in stainless steel

SGO Series. SHEL LAB Gravity Convection Laboratory Ovens SGO1 SGO3 SGO5

Beamex MB METROLOGY TEMPERATURE BLOCK. Portable temperature dry block delivering bath-level accuracy for industrial applications

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

GENERAL PURPOSE INCUBATOR

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

better measurement Simply a question of

Shaking Incubators & Shakers

ETV-SERIES VIBRATION INTERFACE ENVIRONMENTAL TEST CHAMBER. High performance & inherent reliability

emp. & Humid. Chambers

Environmental/Analytical LabCivil Engineering Lab Equipment

END OF YEAR WAREHOUSE CLEARANCE SALE! Ex Demo & Superseded Instrumentation

JUMO dtrans p20 DELTA

emp. & Humid. Chambers

Data Sheet Type FF420. Series 420 Specification Flange / Flange. Series 420 Non-Contact Rotary Torque Transducer

Advanced Force / Torque Indicator

STABILITY TESTING CLIMATIC CHAMBER

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

-86 0 C FREEZER. NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

THYRO-PX SERIES DIGITAL THYRISTOR SCR POWER CONTROLLER UP TO 2900 AMPS

Recirculating Coolers

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

Rockers, Rotators and Mini Shakers

Electromagnetic Flowmeters. Product Overview.

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

AirPort MD8 Battery-Power, Portable Air Sampler

Optidew Vision Optical Dew-Point Meter

Exceptional Choice for Versatile and Reliable Shaking Application

SafeFAST Classic. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

LAUDA Variocool. Numerous options, compact design, easy operation

better measurement Simply a question of

ISO 9001, ISO1400, ISO13485, CE and WHO-GMP certified.

HLX771/772. Inline Flowmeter for compressed air and gases DN15 (1/2 ) - DN80 (3 ) Typical Applications

BENCHTOP SHAKING INCUBATOR

Model 7400 OPERATOR MANUAL

Laboratory Equipment MICROBIOLOGICAL SAFETY CABINETS ENVAIR ECO SAFE COMFORT PLUS CLASS II MICROBIOLOGICAL SAFETY CABINET

Laboratory Equipment MICROBIOLOGICAL SAFETY CABINETS ENVAIR ECO SAFE COMFORT PLUS CLASS II MICROBIOLOGICAL SAFETY CABINET.

Operating Instructions. Angle Seat Control Valve. Type 7020

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

ORBITAL SHAKER. Note: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Mixer/Temperature Control

Providing a constant temperature control and high cooling efficiency.

Sub title. PR series (Toggle type) Servo Hybrid system

GHMsilverline Handheld Instruments

Cytotoxic Safety Cabinets ENVAIR eco safe Plus

ebro has expanded its wide range of loggers in the food sector even further: ebro Data Logger Family EBI 20

Ovens. UL Certified Ovens WON, WOF & WOV models. WiseVen. High-Clean Air Ovens

SonoMeter 30 Energy Meters

Instructions Manual Control Unit RCU205

Penetration. Test Methods

Heavy Duty Orbital Shakers

Techlab - Matériaux de Référence certifiés et Equipements de Laboratoire -

LAUDA Integral. Process thermostats for professional external thermostating across a wide temperature range from -90 up to 320 C

Model 8000XL OPERATOR MANUAL

Installation & Operation Manual

0268 Gear tooth calipers

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor.

SonoMeter 30 Energy Meters

SafeFAST Top. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

Transcription:

KT series 53 Incubators and cooling incubators Refrigerated incubator with Peltier technology The KT series combines outstanding performance with impressive energy efficiency and environmental friendliness. The cooled incubators of the KT series are state-of-the-art in application and protect the samples. Advantages: Energy efficient, environmentally friendly and secure Disinfection at 100 C Broad range of applications Areas of application: Basic Research / Research Institutes Food / Beverage Microbiology

Customer benefits Features Customer benefits Characteristics APT.line Technology Rapid and constant growth of microorganisms Reliable and reproducable incubation results even under full load APT.line for maximum precision Horizontal airflow on both sides for homogeneous temperature distribution Temperature setting with an accuracy of a tenth of a degree Long-term stability of conditions High standard according to DIN 12880 (27-point measurement) Disinfection and Cleaning Interior Chamber Design Cooling and Heating System Controller Input Accessories and Service Reduced risk of contamination Simple and fast cleaning Maximum occupational safety More specimen storage with the same chamber volume Minimal operating costs Energy efficient Environmentally friendly and secure (no refrigerant) Short heating up times High maximum of temperature of 100 C User-friendly input Protection against accidental or unauthorized settings The most important parameters at a glance (e.g. temperature set and actual value) Broad range of applications BINDER INDIVIDUAL for customer-specific solutions Worldwide BINDER Service Disinfection routine at 100 C High-quality stainless steel inner chamber Easily removable elements, no permanent fixtures High energy efficiency Very tight door closure with 2-point door closure Low heat dissipation due to 60 mm insulation Inner glass door Condensation-free interior chamber Peltier cooling unit for finely controlled cooling up to 4 C Powerful conventional heating Pushbutton/rotary knob Key lock and password for access protection Monochrome LCD monitor (5.7 inch) A variety of options: Access ports, shaker platform, interior power socket, outputs, shelves, door heating, interior lighting Data Logger Kits Communication and documentation APT-COMTM software Worldwide service network

Performance characteristics APT.line preheating chamber technology with Peltier cooling system and tubular heater Electronically controlled temperature range 4 C to 100 C BINDER controller with monochrome 5.7 inch LCD monitor and Pushbutton/rotary knob Easy-to-read menu guidance Variable programming options 100 programs with 2 GB internal memory Weekday programming USB port for easy data transfer Independent temperature safety device class 3.1 (DIN 12880) with visual and audio alarm Ethernet interface for communication software APT-COM DataControlSystem Inner glass door made of safety glass 2 stainless steel shelves Units are stackable BINDER test confirmation

Specifications KT 53 Exterior dimensions Housing Width (mm) 660 Height (incl. feet/castors) (mm) 635 Depth (plus connections and fittings) (mm) 630 Depth (incl. connections and fittings) (mm) 695 Wall clearance, rear (mm) 100 Wall clearance, side (mm) 240 Number of doors (ea.) 1 Inner glass door(s) (ea.) 1 Interior dimensions Width (mm) 400 Height (mm) 400 Depth (mm) 334 Interior volume (l) 52 Racks (number standard/max.) 2/5 Load per rack (kg) 15 Permitted total load (kg) 40 Weight (empty) (kg) 65 Temperature data Temperature range ( C) 1) 4-100 Temperature variation at 4 C (± K) 0,3 at 25 C (± K) 0,1 at 37 C (± K) 0,2 Temperature fluctuation max. (± K) 0,1 Recovery time after door was opened for 30 sec 2) at 4 C (min.) 8 at 25 C (min.) 1 at 37 C (min.) 1 Electrical data IP protection class acc. to EN 60529 IP 20 Voltage (± 10%) 50/60 Hz (V) 200-240 1N~ Nominal power (kw) 1,1 Energy consumption 3) at 4 C (W) 250

Specifications at 25 C (W) 90 at 37 C (W) 75 1) Lower values are valid up to an ambient temperature of max. 25 C. 2) To 98% of the set value 3) These values can be used for dimensioning air condition systems The useable interior height depends on the position of racks. All technical data are specified for units with standard equipment at an ambient temperature of 25 C and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time.

Options Numerous access ports For introducing external measuring instruments into the chamber, access ports with silicone plugs in various diameters: 10, 30, 50, 100 mm BINDER Data Logger Kits For independent recording of temperature data. The tailored product solution contains helpful accessories from mounting the logger to the BINDER unit to cable access assistance to the sensor mount. Shaker platform The stable shelf with additional mount is suitable for the operation of shakers.

Options KT 53 Access port with silicone plugs 10, 30, 50, 100 mm Securing elements for additional fastening of racks (1 set of 4 pieces) Anti-slip rubber pads for safe stacking (1 set of 4 pieces) Temperature measurement acc. to DIN 12880 (27 measuring points, at 23 liter units 15 measuring points) at 37 C (98.6 F) or at specified temperature with measuring protocol and certificate Factory calibration certificate. Measurement in center of chamber at specified testing temperature Extension to factory calibration certificate. Each additional measurement at an additional measuring point or temperature Zero-voltage relay outputs accessible via 6-pin DIN socket. Additional module for controlling 2 relay outputs via 2 of the programmable controller s controller contacts. Outputs can be switched on and off either manually or automatically Waterproof interior socket 230 V AC (max. 200 W), IP65 protected, with corresponding plug. Max. allowed operating temperature 50 C (122 F) Additional PT 100 temperature sensor, flexible installation, with external connection, including LEMO connector (3-pin) Analog temperature output, 4-20 ma, with 6-pin DIN socket (output not adjustable) Data Logger Kit T 220: For the continuous temperature recording of -90 C (-130 F) to 220 C (428 F). Kit includes 1 data logger, PT 100 sensor with 2 m extension cable and 1 fixture for the connection at the BINDER unit Data Logger Software: Configuration und evaluation software for all BINDER Data Logger Kits, incl. data cable (RS 232) Interface RS422 Door heating Rack, stainless steel Shelf, perforated, stainless steel Vibration compatible shelf / platform (positioned at bottom level) to be mounted inside the chamber for shaker / spinner / roller operation, max.load 67 kg Reinforced rack, stainless steel, with 1 set of securing elements (1 set of 4 pieces), max. load 60 kg (154 lbs.) Locking door handle with key Temperature safety device, class 3.3 (DIN 12880) with visual alarm Interior lighting (15 W)