Motor Protection Circuit Breakers

Similar documents
About us. Switchgear Factory, Mumbai

NEW. Moulded Case Circuit Breakers New DU Series 20 A to 250 A

Moulded Case Circuit Breakers

Manual Motor Starters. Meta-MEC

ACS motor protection circuit breakers KT 7 Introduction

Motor Protection Circuit Breakers 3VU13 and 3VU16

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

3VU13, 3VU16 Circuit-Breakers

Protection components

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Selection Guide Motor Control Device Solutions

cor Long Run Experience

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Short-circuit current limiter S800-SCL-SR

AF40... AF96 3-pole contactors Technical data

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

Industrial Contactors CTX 3 3P 185A - 800A

Motor Protection Circuit Breaker

About us. Switchgear Factory, Mumbai

Essential equipment for all your requirements


GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

DPX Magnetic only

DPX earth leakage DPX 3 -I earth leakage

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

01 Spectra Plus - Introduction

Data Sheet Manual Motor Starters Ex9SN Series

3 - Protection components Motor circuit-breakers

KT4 Manual Motor Starter

Protection Equipment

Low voltage switch gear

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

UPDATED APRIL Motor Protection Concepts and Type 2 Co-ordination Charts

Manual Motor Starters

Moulded Case Circuit Breakers

Ideal for use as a manual starter

CHINT. NM7 Moulded Case Circuit Breaker

DPX moulded case circuit breakers

Memshield - ACB Ratings & Specifications

Ktec Contactors and thermal overloads

Manual motor starters Overview and benefits

FMotor Circuit Controllers

L&T SWITCHGEAR S A F E & S U R E. Moulded Case Circuit Breakers

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

DX³ 4-pole RCBO 6000 A/10 ka

NDM3 Series. Molded Case Circuit Breaker. Shanghai Liangxin Electrical CO., LTD.

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Motor Starting Solutions Open Type Version, in Kit Form

Self-protected Combination Starters System PKZ 2-SP

Series KTU7 UL489 Molded Case Circuit Breakers

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

DPX Electronic + earth leakage

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

DRX 125 Circuit breaker (not adjustable)

Bulletin 193-T1 Bimetallic Overload Relays

DPX 1600 Electronic release

DRX 250 B/N/H Circuit breaker (not adjustable)

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

US Catalog January Motor protection and control Manual motor starters, contactors and overload relays

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

MS General Information Extended Product Type: MS

Phase + Neutral, neutral on right side

Industry Automation Control Components

Series KTU7 UL489 Molded Case Circuit Breakers

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT

For 200V 3 Phase Motors 185. For 240V 3 Phase Motors 187. For 480Y/277V 3 Phase Motors 189. For 600Y/347V 3 Phase Motors 191. UL Listed CSA Certified

Phase + Neutral, neutral on left side

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

Short form catalogue. Motor protection & control

Technical Information

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

ABB s new control and protection devices

D509E. Manual Motor - Starters

Application Description

Meta Solution. Contactors and Overload relays

DRX 100 B/N/H Circuit breaker (not adjustable)

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Submittal Data Information

Micro Contactor MA Series

Short form catalogue Motor protection and control Manual motor starters

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Thermal Overload Relays - WEG RW Series, 2 Pole

Electronic circuit breaker EBU10-T

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

Data Sheet Manual Motor Starter Ex9S32 Series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Modular contactors and relays

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

ASL09..S 3-pole Contactors - Spring Terminals

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Transcription:

Motor Protection Circuit Breakers

About us Larsen & Toubro is a technologydriven USD 9.8 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field of Engineering, Construction, Electrical & Automation, Machinery and Information Technology. L&T Switchgear, which forms part of the Electrical & Automation business, is India's largest manufacturer of low voltage switchgear, with the scale, sophistication and range to meet global benchmarks. With over four decades of experience in this field, the Company today enjoys a leadership position in the Indian market with growing presence in international markets. It offers a complete range of products including controlgear, powergear, motor starters, energy meters, wires and host of other accessories. Most of our product lines conform to international standards, carry CE markings and are certified. Switchgear Factory, Mumbai

Product Range L&T introduces complete range of Supernova products covering Motor Protection Circuit Breakers, Contactors / Thermal Overload Relays & Motors. Motor Protection Circuit Breakers The new range of MPCBs is meant for protection against short circuit & overload. MO Contactors & RTO Thermal Overload Relays Motors The latest range of Contactors & Thermal Overload Relays, rated from 9A to A. L&T offers higher efficiency phase LT motors, synonymous with ruggedness and reliability, suitable for all industrial applications upto 00 kw.

Motor Protection Circuit Breakers Functions Moulded Case Circuit Breaker and Thermal Overload Relay functions integrated into a highly compact unit known as Motor Protection Circuit Breaker. Circuit Breaker Functions Short circuit protection Overcurrent protection Line protection Thermal Overload Relay Functions Overload protection Phase loss protection Rated current adjustment Ambient temperature compensation } MPCB Advantages Compactness High Breaking Capacity Short circuit protective coordination Reduction in wiring work Ecological design standards Selecting the Appropriate Model Procedure for selecting the appropriate model: Confirm the motor's full load current Threephase load / Select the rated current of MPCB Singlephase load For applications in a singlephase circuit, connect the pole in series Select the branch circuit cable & confirm the control panel specifications Confirm the shortcircuit current of the circuit Select the operating characteristics Same characteristics as desired for a standard thermal overload relay Adjustable thermal magnetic trip type MPCB Longtime operating type or quick operating type thermal overload relay desired Instantaneous trip type MPCB

Typical Problem in the Conventional System and their Solution by using MPCB ShortCircuit Breaking Capacity When numerous small and medium motor loads exist in a circuit requiring high breaking capacity, there is no high breaking capacity circuit breaker with a small rated current for a short circuit protection. The MPCB can be used in ka short circuit current circuits for threephase, 0V motors with rated capacity upto kw, and in ka short circuit current circuits for three phase, V motors with rated capacity up to 0kW. Backup breaking system When backup MCCB is installed upstream to solve the problem described in Shortcircuit breaking protection above, a short in one of the load circuits also trips the upstream breaker and stops the other operating circuits. Despite their compact size, the MPCB provides highperformance shortcircuit current breaking. They eliminate the need for an upstream circuit breaker for backup use. Overload Protection Motor Protection breakers cannot be adjusted to match the rated current of the motor being protected. Equipped with a wide range current adjustment dial (with maximum/minimum ratio of. to.), the MPCB easily adjusts to match the rated current of the motor, for optimum protection. Control Panel Size Considerable space is required to install a backup circuit breaker or a combination starter consisting of a circuit breaker and a thermal overload relay. As a result, the panel size has to be increased. The compact size of the MPCB, including overload relay functions, enables a smaller installation area with less wiring space, for a reduction in panel size.

Technical Specifications MOG S MOG H MOG H MOG HM MOG HM Standards IEC097,, IEC097,, IEC097,, IEC097,, IEC097,, Handle type Rocker Rotary Rotary Rotary Rotary Number of poles Frame A A A A A Rated insulation voltage (Ui) AC90V AC90V AC0V AC90V AC0V Rated operational voltage (Ue) AC00 90V AC00 90V AC00 90V AC00 90V AC00 90V Rated impulse withstand voltage (Uimp) KV KV 8KV KV 8KV Rated frequency AC / 0Hz AC / 0Hz AC / 0Hz AC / 0Hz AC / 0Hz Utilization Category (IEC97 / 97 ) AC / Cat. A AC / Cat. A AC / Cat. A AC / Cat. A AC / Cat. A Maximum motor capacity AC 7. kw (at 00 0V), kw (at 80 0V) 7. kw (at 00 0V), kw (at 80 0V) kw (at 00 0V), 0 kw (at 80 0V) 7. kw (at 00 0V), kw (at 80 0V) kw (at 00 0V), 0 kw (at 80 0V) AC Electrical/Mechanical endurance 000 (A:70000) / 000 (A:70000), (cycles / hour) 000 (A:70000) / 000 (A:70000), (cycles / hour) 00 / 000, (cycles / hour) 000 (A:70000) / 000 (A:70000), (cycles / hour) 00 / 000, (cycles / hour) Tripping device Thermal Magnetic Thermal Magnetic Thermal Magnetic Magnetic Magnetic Ambient temperature compensation 0 C ~ + 0 C 0 C ~ + 0 C 0 C ~ + 0 C 0 C ~ + 0 C 0 C ~ + 0 C Overload, Phase loss protection yes (according to IEC097 ) yes (according to IEC097 ) yes (according to IEC097 ) None None Trip Indicator Yes Yes Yes Yes Yes Test Trip Function Yes Yes yes Yes Yes Instantaneous release X Ie max. x Ie max. x Ie max. x Ie max. x Ie max. Terminal type Screw terminal, M slotted Screw terminal, M slotted Box terminal, M slotted Screw terminal, M slotted Box terminal, M slotted Wire size Solid/Stranded Without/With end sleeve mm x / 8 8 AWG x mm x / 8 AWG x mm x / 8 8 AWG x mm x / 8 AWG x mm x / 8 AWG x mm x / 8 AWG x mm x / 8 8 AWG x mm x / 8 AWG x mm x / 8 AWG x mm x / 8 AWG x Product weight (Kg) 0. 0. 0.78 0.7 0.78 Dimensions (mm) W x H x D x 90 x x 90 x x x 9 x 90 x 79 x x 9 Relative humidity ~ 8%RH No dew formation or freezing due ~ 8% RH No dew formation or freezing due ~ 8% RH No dew formation or freezing due ~ 8% RH No dew formation or freezing due ~ 8% RH No dew formation or freezing due Standard service condition Operation altitude Atmosphere Up to 000m to rapid temperature change allowed Atmosphere having no excess Vapour, Steam, Dust, Corrosive gas, Salt, Flammable gas Up to 000m to rapid temperature change allowed Atmosphere having no excess Vapour, Steam, Dust, Corrosive gas, Salt, Flammable gas Up to 000m to rapid temperature change allowed Atmosphere having no excess Vapour, Steam, Dust, Corrosive gas, Salt, Flammable gas 000m to rapid temperature change allowed Atmosphere having no excess Vapour, Steam, Dust, Corrosive gas, Salt, Flammable gas Up to 000m to rapid temperature change allowed Atmosphere having no excess Vapour, Steam, Dust, Corrosive gas, Salt, Flammable gas

Breaking Capacity at Different Voltages MOG S Rating Ie (A) AC0V AC0V ACV AC00V AC0V AC0V AC0V AC90V AC00V Icu (A) 00 0. 0. 00 0. 0. 000 0. 0. 00 0. 0. 0 0. 00. 0.. 000. 00. 0. 00 9 MOG H MOG HM Rating Ie (A) AC0V AC0V ACV AC00V AC0V AC0V AC0V AC90V AC00V Rating In (A) AC0V AC0V ACV AC00V AC0V AC90V AC0V AC0V AC00V Icu (A) Icu (A) 00 00 000 00 0 00 0 000 00 0 00 00 000 0 00 0. 0. 0. 0. 0. 0. 0. 0. 0....... 9 0 9 8 8 00 00 000 00 0 00 0 000 00 0 00 00 000 0 00 0. 0. 0. 0.... 0 8 8 MOG H MOG HM Rating Ie (A) AC0V AC0V ACV AC00V AC0V AC0V AC0V AC90V AC00V Rating In (A) AC0V AC0V ACV AC00V AC0V AC90V AC0V AC0V AC00V Icu (A) Icu (A) 00 000 00 00 8 0 00 000 00 00 0 7

Ordering Information Thermal & Magnetic Trip Rocker Frame size (mm) Rating (A) 0.A 0.A 0.A 0.A.0A.A.A.A.A.0A.0A Motor Rating at V, Hz (kw) 0.09 0. 0. 0. 0.7..0.00.0 Designation Thermal Release Range (A) 0. 0.A 0. 0.A 0. 0.A 0. 0.A 0..0A.0.A..A. A.0.A..0A 9.0.0A Cat. Nos. ST889OOOO ST890OOOO ST89OOOO ST89OOOO ST89OOOO ST89OOOO ST89OOOO ST89OOOO ST897OOOO ST898OOOO ST899OOOO Breaking Capacity mm MOG S ka Thermal & Magnetic Trip Rotary ka Frame size (mm) mm mm Rating (A) 0.A 0.A 0.A 0.A.0A.A.A.0A.A.0A.0A.0A 0.0A.0A.0A.0A 0.0A.0A.0A Motor Rating at V, Hz (kw) 0.09 0. 0. 0. 0.7..0.00.0 7. 9.00..00.00 0.00.00.00 Designation MOG H MOG H Thermal Release Range (A) 0. 0.A 0. 0.A 0. 0.A 0. 0.A 0..0A.0.A..A..0A.0.A..0A 9.0.0A.0.0A.0 0.0A 9.0.0A.0.0A.0.0A 8.0 0.0A.0.0A.0.0A Cat. Nos. ST90OOOO ST90OOOO ST90OOOO ST907OOOO ST908OOOO ST909OOOO ST9OOOO ST9OOOO ST9OOOO ST9OOOO ST9OOOO ST9OOOO ST9OOOO ST97OOOO ST98OOOO ST99OOOO ST90OOOO ST9OOOO ST9OOOO Breaking Capacity ka ka Instantaneous Trip Rotary 8 Frame size (mm) mm mm Rating (A) 0. 0.A 0.A 0.A.0A.A.A.0A.A.0A.0A.0A 0.0A.0A.0A.0A 0.0A.0A.0A Motor Rating at V, Hz (kw) 0.09 0. 0. 0. 0.7..0.00.0 7. 9.00..00.00 0.00.00.00 Designation MOG HM MOG HM Thermal Release Range (A) Cat. Nos. ST9OOOO ST9OOOO ST9OOOO ST9OOOO ST97OOOO ST98OOOO ST99OOOO ST90OOOO ST9OOOO ST9OOOO ST9OOOO ST9OOOO ST9OOOO ST9OOOO ST97OOOO ST98OOOO ST99OOOO ST90OOOO ST9OOOO Breaking Capacity ka ka

Accessories Features All accessories can be used with MOG S (mm wide), MOG H (mm wide) and MOG H (mm wide) frames Shunt trip and undervoltage trip devices are available in a wide range of operating voltages IP0 terminal cover prevents accidental contact to electrically charged parts Auxiliary contact blocks : MOGAXF, MOGAXL These blocks are linked to the ON/OFF operation of the MPCB. Up to two contact blocks can be mounted to the right/left front and up to two contact blocks can be mounted to the left side. Alarm contact blocks : MOGTAF This block operates when the MPCB trips due to overload, phaseloss, or shortcircuit. It is not linked to the ON/OFF operation of the MPCB. Note : Operation can be checked with the test trip function. Auxiliary and alarm contact blocks : MOGATL This contact block combines auxiliary contact and alarm contact that operate in the event of an overload, phase loss, or shortcircuit. Alarm contact is not linked to the ON/OFF operation of the MPCB An alarm is displayed in the contact block s indicator when the alarm contact operates Note : Operation can be checked with the test trip function. Shortcircuit alarm contact block : MOGSAL The contacts operate only when the MPCB has tripped due to a shortcircuit When these contacts operate, the blue reset button extends out, and a trip indication is displayed The power to the MPCB can be turned ON after pressing the reset button Note : Operation can not be checked with the test trip function. Be sure to press the reset button before mounting to the MPCB. Shunt trip devices : MOGST This device is used to remotely trip the MPCB. Notes: This device cannot be used together with an undervoltage trip device When the MPCB trips with the shunt trip device, press the reset button before turning ON the power 9

Accessories Undervoltage trip devices : MOGUV This device automatically trips the MPCB when the control circuit voltage drops below the specified value. Notes: This device cannot be used together with a shunt trip device When the MPCB has been tripped with the undervoltage trip device, press the reset button before turning ON the power External operating handles : MOGEH To operate the MPCB without opening the panel door Equipped with an interlock mechanism that prevents someone from opening the panel door when the MPCB is in the ON state The shaft can be cut to match the distance between the MPCB and the panel door Door interlock function OFF lock function Note: Padlocks not included. Release screw allows the door to be opened with the handle in the ON position IP enclosure Ratings of accessories Accessory type Part number Standard Rated operational current (A) 8V AC AC V AC 0V AC 00V AC 0V AC 90V AC 8V DC DC V DC 0V DC Min. voltage and current Auxiliary contact block/front Auxiliary contact block/side Alarm contact block Aux. and alarm contact block Shortcircuit alarm contact block MOGAXF MOGAXL MOGTAF MOGATL MOGSAL IEC 097......... 0. 0. 0..8.8 0.. 0... 0.7 0. 0.7 0. 0. 7V, ma Accessory type Standard Rated insulation voltage (V AC) No. of ONOFF operations Operating time (ms) Power consumption Voltage range Time rating of coil (s) Inrush (VA/W) Sealed (VA/W) Tripping voltage (V) Closing voltage (V) Shunt trip device MOGST 0.7 to.ue AC: Continuous DC: IEC 097 90 00 0 / 8/. Undervoltage device MOGUV 0. to 0.7Ue 0.8 to.ue AC: Continuous Note: Ue: Rated Voltage

Selection Chart Fuseless Protection for DOL Starter Feeders with MPCB MOGHM/HM Coordination, Iq= ka at V, Ø, Hz as per Standards : IEC 097, IS 97 (Part /Sec. ), EN 097 The selection is valid only for complete L&T combinations i.e. MPCB + Relay + Contactor In any case if this combination is changed to accommodate another brand / rating of MPCB etc. it shall be the responsibility of the person making such a change to assure type performance Selection is for normal starting conditions with starting time According to Coordination, Iq=kA at V, Ø, Hz Sr. No. Motor Rating: Ø, V, Hz Contactor Overload Relay MPCB (Only Magnetic) hp kw I L Range (A) Rating I M (A) 0. 0.09 0.0 MO RTO 0. 0. MOG HM 0. 0. 0. 0. MO RTO 0. 0. MOG HM 0. 0. 0. 0.7 MO RTO 0. 0.7 MOG HM 0. 0.9 0.7 MO RTO 0.7.0 MOG HM 0. 0. 0.90 MO RTO 0.7.0 MOG HM. 0. 0.7.0 MO RTO.0. MOG HM. 7 0.7 0..0 MO RTO.. MOG HM. 8 0.7. MO RTO.8.7 MOG HM. 9...70 MO RTO.. MOG HM.7.0.00 MO RTO.. MOG HM.. MO RTO..0 MOG HM...80.80 MO RTO..0 MOG HM...00 MO RTO.0.0 MOG HM..00.0 MO RTO. 9.0 MOG HM.70 7.90 MO RTO. 9.0 MOG HM..00 8. MO RTO. 9.0 MOG HM 7. 9.00 MO MO RTO 8.. MOG HM 8 7...0 MO MO RTO 8.. MOG HM 9 7..80 MO 8 MO RTO. 8 MOG HM 0 0. 9.0 9.00 MO MO RTO 7 MOG HM.00.00 MO MO RTO 7 MOG HM 7..00.00 MO MO RTO MOG HM 0.00 9.00 MO MO RTO MOG HM 0 8.0.00 MO 0 MO RTO 0 0 MOG HM 0. 0.00 MO 0 MO RTO MOG HM.00 7.00 MO MN 0 MOG HM

Selection Chart Fuseless Protection for DOL Starter Feeders with MPCB MOGS/H/H '' Coordination, Iq= ka at V, Ø, Hz as per Standards : IEC 097, IS 97 (Part /Sec. ), EN 097 Sr. No. 7 8 9 7 8 9 0 Motor Rating: Ø, V, Hz Contactor Overload Relay MPCB (Only Magnetic) 0. 0. 0. 0. 0. 0. 0.7..7.. 7.. 7. 0 0 hp kw I L Range (A) 0.09 0. 0. 0.9 0. 0.7 0. 0.7..0.80..00.70.00.. 7. 9.0.00.00 8.0..00 0.0 0. 0.7 0.7 0.90.0.0..70.00.80.00.0 7.90 8. 9.00.0.80 9.00.00 9.00.00 0.00 7.00 MO MO MO 8 MO MO MO MO 0 MO 0 MO MOG S / MOG H MOG S / MOG H MOG S / MOG H MOG S / MOG H MOG S / MOG H MOG S / MOG H MOG S / MOG H MOG S / MOG H MOG S / MOG H MOG S / MOG H MOG S / MOG H MOG S / MOG H MOG S / MOG H MOG S / MOG H MOG S / MOG H MOG S / MOG H MOG H MOG H MOG H MOG H MOG H MOG H MOG H MOG H Rating I M (A) 0. 0. 0. 0. 0. 0.............. 9 0 9 8 0 0 0

Selection Chart Fuseless Protection for DOL Starter Feeders with MPCB MOGS/H/H '' Coordination, Iq= ka at V, Ø, Hz as per Standards : IEC 097, IS 97 (Part /Sec. ), EN 097 Sr. No. 7 8 9 7 8 9 0 7 Motor Rating: Ø, V, Hz Overload Relay MPCB Contactor hp kw FLC, In (A) Range (A) 0. 0. 0. 0. 0. 0. 0.7..7. 7.. 7. 0 0 0 0.09 0. 0. 0.9 0. 0.7 0. 0.7....8..7.. 7. 9. 8.. 0. 0. 0. 0.7 0.7 0.9....7..8. 7.9 9..8 9 9 0 7 0 MNX 9 MNX 9 MNX 9 MNX 9 MNX 9 MNX 9 MNX 9 MNX 8 MNX MNX MNX MNX 0 MNX 0 MNX MNX 70 MNX 80 MNX 80 MOG S / MOG H MOG S / MOG H MOG S / MOG H MOG S / MOG H MOG S / MOG H MOG S / MOG H MOG S / MOG H MOG S / MOG H MOG S / MOG H MOG S / MOG H MOG S / MOG H MOG S / MOG H MOG S / MOG H MOG S / MOG H MOG S / MOG H MOG S / MOG H MOG S / MOG H MOG H MOG H MOG H MOG H MOG H MOG H MOG H MOG H MOG H MOGH Rating 0. 0. 0. 0. 0. 0. 0. 0............. 9 0 9 9 8 0 8 0

Selection Chart Fuseless Protection for DOL Starter Feeders with MPCB MOGHM/HM '' Coordination, Iq= ka at V, Ø, Hz as per Standards : IEC 097, IS 97 (Part /Sec. ), EN 097 Motor Rating, V, ph. FLC Relay Sr. No. hp kw (A) Range (A) Contactor MPCB (Only Magnetic) Rating 0. 0.09 0. 0. 0. MOG HM 0. 0. 0. 0. 0. 0.7 MOG HM 0. 0. 0. 0.7 0. 0.7 MOG HM 0. 0. 0.9 0.7 0. MOG HM 0. 0. 0.9 0. MOG HM 0. 0.7. 0.9. MOG HM. 7 0.7 0.... MOG HM. 8 0.7... MOG HM. 9...7.0. MOG HM.7..0. MOG HM..8.0.0 MOG HM..8.8. 7. MOG HM... 7. MOG HM... 7. MOG HM.7 7.9 MOG HM. 9 MOG HM 7 7... 9 MNX MOG HM 8 7.. MNX MOG HM 9. 9. 9. MNX MOG HM 0 0 0 MNX MOG HM 7. 0 MNX MOG HM 0 9 0 MNX MOG HM 8. 0 MNX 0 MOG HM 0 0. 0 MN 0 MNX MOG HM 7 MN 0 MNX 70 MOG HM 0 0 MN 7 MNX 80 MOG HM 7. 0 MN 7 MNX 80 MOG HM

IT Characteristics MOG S (0.A A) MOG H (0.A A) 00 00 0 0 poles from cold state poles from cold state Average Tripping Time (s) 0. poles from hot state poles from cold state Instantaneous tripping characteristic is set at 00% of the maximum current setting Average Tripping Time (s) 0. poles from hot state poles from cold state Instantaneous tripping characteristic is set at 00% of the maximum current setting 0.0 0.0 0.00 Multiples of current setting x Ie[A] 0.00 Multiples of current setting x Ie[A] MOG H (A A) 00 0 Average Tripping Time (s) poles from hot state poles from cold state poles from cold state Instantaneous tripping characteristic is set at 00% of the maximum current setting 0. 0.0 0.00 Multiples of current setting x Ie[A]

IT Characteristics MOG HM (0.A A) 00 0 Tripping Time (s) Instabtabeous tripping characteristic is set at ~ 0% of the rated current 0. 0.0 0.00 Multiples of rated current x In[A] 00 MOG HM (A A) 0 Tripping Time (s) Instabtabeous tripping characteristic is set at ~ 0% of the rated current 0. 0.0 0.00 Multiples of rated current x In[A]

Overall Dimensions MOG S (0.A A).. Ø. 7 M L L L M 7 8.. MOG H & MOG HM (0.A A) Ø. 9 M L L L M 8. 7 90 7 9 7. 90 7 9. 7 T T T...7.. 7 T T T. 7..7. MOG H & MOG HM (A A).. 7.8 9. 88. L L L M...8 8 0. 9.8 T T T. 7

Overall Dimensions Trip Alarm Contact Front NO 9 M... MOGTAFINO 7.8 8.8..7 8 I> MOGTAFINC 8.9. 8. I> S / C Alarm Left NO + NC 8.7.7 9.8 8.7. M. Trip indication (reset by hand). MOGSALICO 87 8 70...8.8 7. 90 I> 8 88. 8

Overall Dimensions External Operating Handle (Applicable for Frame & ) MMS A ~ RESET TRIP ON Ø. MMS OFF. Ø8.±0. () MMS.7.±0.. Handle.~ X OFF. (Ø~Ø8) 8 X min X max 7 Frame +9 +89 Frame + +0 B Aux. Contact Front NO 9 M... MOGAXFINO ().8 8.8.7 I> () MOGAXFINC () 8.9 8. I> () 9

Overall Dimensions Aux. Alarm Left NO 9.8 8.7.7. M. 8.7 Indication window. MOGATLNO 7 70...8.8 7. 90 77 I 78 7. Aux. Contact Left NO. 9.8 M. 8.7.7 8.7 Left side Right side 70...8.8 7. 90.. MOGAXLNO MOGAXLCO MOGAXLNC () () () () () () I () () I () () I () () 0

Overall Dimensions Shunt trip and under voltage release MOG ST & MOG UV.8 8 M. 8.7 8.7. 70. 7. 90. Accessories for MPCB Cat. Nos. Description Model Numbers Position ST9OOOO ST9OOOO ST9OOOO ST9OOOO ST9OOOO ST97OOOO ST98OOOO ST99OOOO ST9OOOO ST9OOOO ST9OOOO ST9OOOO ST9OOOO ST9OOOO F Front Mounting L LHS Mounting R RHS Mounting Auxiliary Contact Front mtg. NO Auxiliary Contact Front mtg. NC Auxiliary Contact Left side mtg. NO Auxiliary Contact Left side mtg. NO + NC Auxiliary Contact Left side mtg. NC Trip Alarm Contact Front mtg. NO Trip Alarm Contact Front mtg. NC Auxiliary + Alarm Left side mtg. NO Short circuit alarm Left side mtg. NO + NC Shunt trip V DC Shunt trip V, Hz Shunt trip 0V, Hz Under Voltage release, V, Hz Under Voltage release, V, Hz MOGAXF NO MOGAXF NC MOGAXL NO MOGAXL CO MOGAXL NC MOGTAF NO MOGTAF NC MOGATL NO MOGSAL CO MOGST MOGST MOGST MOGUV MOGUV F (Slot / Slot ) F (Slot / Slot ) L L L F (Slot only) F (Slot only) L L R (one at a time) Terminal Marking NO NC, (, ), (, ) ", (, ), (, )", (, ) 7, 8 "7, 7 77, 78" 87, 88 C, C D, D, (, ) ", (, ), (, )", 8, 8 Note: ) On LHS any accessories can be fitted (Alarm contact followed by Auxiliary contact) MOGATL NO + MOGAXL CO MOGSAL CO + MOGAXL CO ) On RHS only accessory can be fitted (Shunt trip release or Undervoltage release) ) Any Front mounted accessories are possible at a time. Front mounted TAF to be fitted only in slot Front mounted auxiliary contact can be fitted in slot / slot