LEVEL SWITCH WITH 1 FLOAT

Similar documents
Hermetically Sealed Power Contact

Operating Instructions

ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. Motor cable length 0.3 m. T [mm]

3.1 Power RC Snubber Networks : - STRC series Applications : Constructions : Mounting systems : Electrical Characteristics : Circuits :

Methods of Operating Reed Switches

Cautions in Using The Relays 1/5

ATL 12 ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. La =Lc + Stroke Lc T. Rear bracket SP. Stroke. Capacitor

MAGNETO-INDUCTIVE POSITION DETECTORS

ELECTROMAGNETIC LEVELS

MGL Avionics AvioGuard. Fault protected, wide input range, isolated, DC to DC converter for avionics applications

Reed, Electronic. MOVEMENT > Series CST-CSV-CSH proximity switches GENERAL DATA

Magnetic Proximity Switch MSW-L (Latching Type) DC/AC Version CE Classification: M2C235AU9

THE PROTECTION OF INDUSTRIAL CAPACITOR BANKS BY CURRENT LIMITING FUSES. By M.J. Smart and B. Wadcock

Control Relays Overview

Level Switches. Level Float Switch. Visual/Electrical Low Level. LEN Series RL Series. LV/E1 Series. S e c t i o n

ACME SCREW LINEAR ACTUATOR. OVERALL DIMENSIONS La =Lc + Stroke Lc T Capacitor

Reed, Electronic. MOVEMENT > Series CST-CSV-CSH proximity switches GENERAL DATA

Reed, Electronic. MOVEMENT > Proximity switches Series CST-CSV-CSH GENERAL DATA

1000 VDC 1250 VDC 125 VAC 250 VAC J K M 125 VAC, 250 VAC

CP Automatic capacitor bank

Schmidt Mess- und Regeltechnik

ISTEK-C A 750V DC Contactor

PO Box 2484 Rowville Vic 3178

Projectile Impact Tester

COOPERATIVE PATENT CLASSIFICATION

Miniature Liquid Level Sensors

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet

BALL SCREW LINEAR ACTUATOR OVERALL DIMENSIONS LENGTH

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

DG 023 DG 024 DG 025 DG 041 DG 042. Clogging Indicators

Solid-State Relays. Solid-State Relays. Features. Description. Overview

Using Electricity. Summary Notes. 1. From the Wall Socket Household appliances. Earth wire and safety.

Solid-State Relays. Solid-State Relays. Features. Description. Overview

RSS Series Panel Mount Solid State Relays. 4,000 RMS (minute)

XL/127-PLAST-SL - VERTICAL LEVEL GAUGES 5 WITH MIN LEVEL ELECTRICAL SIGNAL

CORROSION RESISTANT IN LINE FLOW SWITCHES

Electrical Energy and Power Ratings

KOBOLD VKA FLOWMETER/SWITCH. User Instructions. Manual-VKA_03-04

KOBOLD SV FLOWMETER/SWITCH. User Instructions

BALL SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. MASS [Kg] STROKE T STROKE LENGTH STROKE LENGTH. standard brake CODE

SiC Hybrid Module Application Note Chapter 1 Concept and Features

Twin relays. Twin coil relays TCR and TCR-F. Convenience. Powertrain Systems. Safety Security Body Driver Information.

Electric cars: Technology

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG SKYLLA 24/100 3-PHASE CE

Switchgear for Luminaires

Magnetic Paddle Flow Sensor/Switch for Easy On/Off Control

M-100 Adjustable flow switch with right-angle flow

Filters for Power Lines

Miniature Circuit-Breakers (MCBs)

Electro - Hydraulics. & Pneumatics. Electro Hydraulic Press. Comparison. Electro Hydraulics. By: Alireza Safikhani

D4B- N. Safety Interlock Switches. Safety Limit Switch. Specifications. Standards and EC Directives. Certified Standard Ratings D4BN

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012

Power Supplies POWER SUPPLIES TRANSIENT VOLTAGE SUPPRESSORS POWER LINE FILTERS. AC to DC Power Supply Units. AC to 24VDC Regulated Primary Switching

Automotive Relays Application Notes. Automotive Applications

LIQUID LEVEL FLOAT SWITCH. F7 Series INSTALLATION AND OPERATIONS MANUAL. Single-Point, Vertically-Mounted Liquid Level Float Switch

Standard AC Motors E-75

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -

PERFORMANCE SPECIFICATION SHEET

SPECIFICATIONS LOW COST 2404R CHARGER

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

Solid-State Relays. Solid-State Relays. Features. Description. Overview

Power System Solutions (PSS)

Introduction fo FPV Series Multilayer Chip Varistor

For industrial applications For marine applications With proximity switch. Piston type flow switches

PKP Prozessmesstechnik GmbH Borsigstraße 24 D Wiesbaden-Nordenstadt Tel.: ++49-(0) Fax: ++49-(0)

QS20.241, QS C1

Application Note CTAN #127

ELEC-E8421 Components of Power Electronics. Protection of Power Semiconductor Devices

Features. Description. Table of Contents

Switches Unlimited Phone: * Fax:

P1Z Series Guided Version

SL Series Application Notes. SL Series - Application Notes. General Application Notes. Wire Gage & Distance to Load

Automotive Relays PCB Single Relays. Micro Relay K (THT THR)

Page 2-4 Page 2-8. Page Page 2-13

D2SW. Sealed Subminiature Basic Switch. Ordering Information Model Number Legend D2SW-

OPERATION AND INSTRUCTION MANUAL. EP Series. Battery Chargers and Power Supplies

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

Maintenance Instructions & Parts List

Technical Information Solid State Relays. Glossary. Solid State Relays

Technical Description

KSR Flow Switches

Power Supply EL

CLASSIFIED 5 MAGNETISM ELECTROMAGNETIC INDUCTION GENERATOR MOTOR - TRANSFORMER. Mr. Hussam Samir

PC T8 TEC, W PC TEC

AF series contactors (9 2650)

Horizontal And Vertical Centrifugal Pumps

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

FL ballasts Electronic fixed output PC T8 TEC, W PC TEC T8

Twin coil relays TCR and TCR-F. Chassis Systems. Conditions

CHAPTER 3 TRANSIENT STABILITY ENHANCEMENT IN A REAL TIME SYSTEM USING STATCOM

Level switches Series LC40 Float level switch for liquids

CAPACITOR DISCHARGE STUD WELDING SYSTEMS

DG 060 DG 061 DG 062 DG 063 DG 064 for Pressure and High Pressure Filters Operating pressure up to 600 bar Response/switching pressure up to 5,0 bar

LIMITED ANGLE TORQUE MOTORS

ALIEM USER MANUAL R. Bocconi. REV. DATE Checked and Approved R. T.

Presented to the IAPMO Standards Review Committee on December 9, 2013

Maximum output power with circulator Wo 6 kw. Maximum output power without circulator Wo 5 kw

Unit 32 Three-Phase Alternators

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S

Transcription:

RIL210 LEVEL SWITCH WITH 1 FLOAT LEVEL Immersion level controller with 1 or 2 control points It can be used for dirty liquids, water, petroleum, cutting oils, and tolerates the presence of metal and ferrous particles, since the float does not hold a magnet and is integral with the rod. The required length can be obtained simply by cutting the steel rod, using an ordinary pipe cutter; or the switching point can be varied by using a float with through hole allowing the required liquid control point to be modified whenever necessary. One float can operate just one Reed (min. or max. level), or two Reeds (min. and empty and extra max. level) thus meeting the most complex needs. Total safety since the electrical part is completely separate in the tank side and perfectly sealed with respect to the external side by means of ultrasonic welding and resin coating of the pins. The nylon-glass body is very strong and very resistant with respect to chemicals, and is ideal as an insulating container for the Reed contacts. The RIL210 come standard with rods suitable for control of a max. measurement of 500 or 1000mm. To obtain specific measurements, refer to the table on the next page. They can be ordered already arranged for the control of predetermined measurements. Fixing diagram Connection: Connector CE EN 175301-803-A IP65 PG.9/11 Through float On request the float can be supplied with through hole and therefore be positioned in the required position without having to cut the rod (which can therefore be as long as the height of the tank). If necessary, the liquid control point can be subsequently be modified as required by simply moving the float.

Connection rod cutting table (N.B. : Carry out the cutting measurement with the rod in traction with respect to the body) CONTROL VALUE L= (mm) ROD CUTTING FOR MIN.LEVEL A= (mm) CONTROL VALUE L1= (mm) ROD CUTTING FOR MAX.LEVEL B= (mm) 90 100 110 120 140 160 180 220 240 260 280 300 340 360 380 400 420 440 460 480 500 520 540 560 580 600 620 640 660 680 720 740 760 780 800 840 860 880 900 920 940 960 980 1000 62 H= 35 62 H= 45 62 H= 55 116 137 158 179 221 242 263 284 305 326 347 368 389 410 431 452 473 494 515 511 532 553 574 595 616 637 658 679 721 742 763 784 805 826 847 868 889 910 931 952 973 994 1015 90 100 120 140 160 180 220 240 260 280 300 340 360 380 400 420 440 460 480 500 520 540 560 580 600 620 640 660 680 720 740 760 780 800 840 860 880 900 62 H1= 35 62 H1= 45 131 152 173 194 215 236 257 278 299 341 362 383 404 425 421 442 463 484 505 526 547 568 589 610 631 652 673 694 715 736 757 778 799 841 862 883 904 925 Advantages of the range 1- These electromagnetic level gauges in Kits can be obtained in the required length L simply by cutting the control rod with an ordinary pipe cutter and press fitting the float in the cutting place (see table for cutting). 2- The control rod can commutate the signal of 1 or 2 Reeds in sequence (with single or exchange contact). 3- The float does not hold magnets, therefore the Level can also be used in the presence of dirty liquids or ferrous particles. H = 35 (L = 90 mm) H = 45 (L = 100 mm) H = 55 (L = 110 mm) H = 60 (L = 120-500 mm) H = 90 (L = 501-1000 mm) L-L1 = 100 mm A-B = 90 mm H = 35 (L = 90 mm) H = 45 (L = 100 mm) H = 55 (L = 110 mm) H = 60 (L = 120-500 mm) H = 90 (L = 501-1000 mm) H1 = 35 (L1 = 90) H1 = 45 (L1 = 100) H1 = 70 (L1 = 120-1000 mm)

RIL210/ G1-F (FLANGE) RIL210 / G1-1 GAS Model CONNECTION ELECTRICAL CONTACTS REED RIL210 FLANGE 3 or 2 HOLES S1 Closed in 1" GAS absence of 1" 1/4 GAS liquid 1" 1/4 GAS S1A Closed in presence of liquid S2 Exchange S3 Minimun empty S4 Special Minimun empty 3A. 60W 60 V.A. 230VDC 250VAC EXCHANGE REED 1A. 20W 20 V.A. 150VDC 150VAC TEMPERATURE -20 +80 C (on request) -20 +120 C PRESSURE 10 Bar

IMPORTANT The electrical characteristics of the reed contacts, given in the descriptive tables, are supplied by the manufacturer. If the level indicator is connected to an inductive, resistive or capacitive load or lamp, permanent or temporary sticking of the contact may occur for particular load values, thus compromising its proper operation. It is advisable to appraise the nature of the load before connecting the level indicator. After identifying the type of load the level indicator will be connected to, a contact protection circuit must be included between the indicator and load, according to the following notes: INDUCTIVE LOAD When the reed contacts are used to control inductive loads such as motors, solenoid valves or solenoids, due to the very nature of the load, they are subject to voltage peaks (transients) during normal operation. These peaks can cause direct damage to the reed contact, significantly reducing its service life. With continuous operation, protection of the contact is relatively easy by simply installing a diode in parallel with the load. The polarity must be respected. When the circuit is alternating, the diode cannot be used. Therefore an arc suppression unit must be used; in general this is a block of resistances and capacitances connected together in series and in parallel with the reed. When the contact remains open for a long time, it is advisable to install a varistor in parallel with the load.

CAPACITIVE AND RESISTIVE LOAD Unlike the inductive load, in this case it is the current peaks caused by the charge and discharge of the capacitances that can cause faults in the reed contacts. When a capacitive load is commutated (e.g. even just the capacity of the cables) a discharge of strength depending on the capacity and length of the cables (considered as a series of resistances) passes through the reed contact. The discharge current can be limited by a resistance in series with a capacitor, all in parallel with the load. The sizing of the resistance and the capacitance depends on the characteristics of the circuit. In any case the values can be determined in the most effective way to minimise the effects of this discharge. The figure shows typical examples of circuits protecting against charge / discharge current peaks. LAMP In fact, when the lamp filament is cold, i.e. the lamp is off, its resistance is approximately 10 times smaller than when it is hot. This means that if a reed contact is used to commutate a lamp, when it closes, even for just a short time, a current 10 times larger than that which would circulate during operation passes through the reed contact. If this value exceeds the maximum permissible, the contact could become damaged or its life expectancy reduced. This overcurrent can be limited by installing a resistance of adequate value in series with the lamp. Another possibility is to connect a resistance in parallel with the reed, so that the lamp filament is preheated, and therefore not have extra current when the contact closes.