Thank You! For purchasing our eflux Flow pump. Please read all instructions before getting in the LOOP!

Similar documents
gamma uv Aquarium Ultraviolet Sterilizers

MODEL INSTALLATION INSTRUCTIONS. 12 Volt UTILITY PUMP

PR 20/20. WARNING Buyer/User assumes all responsability for safety and proper use not in accordance with the directions and sately labels.

Fission. Nano-Protein Skimmer. Instructions for Model#8100

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

MODEL P INSTALLATION INSTRUCTIONS

SUBMERSIBLE SUMP PUMPS

TC TC Operating instruction

MODEL H INSTALLATION INSTRUCTIONS

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

SUBMERSIBLE SUMP PUMPS

INSTALLATION GUIDE KPF Single Lever Kitchen Faucet With Pull-Out Sprayer

Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product.

AQT-56SE ELECTRONIC SERIES PROGRAMMING MANUAL CONTROL VALVES

INSTALLATION GUIDE AND USER MANUAL

NORTHSTAR 154 BATH/SPA TV. Installation Instructions

AQT-56 POWERFLO SERIES SERVICE MANUAL CONTROL VALVES

SUBMERSIBLE FILTRATION & WATERFALL PUMP

SuperFlo 9,000 High Volume Pump Product Manual

Single Lever Pull-Out Kitchen Faucet

Installation Operation Parts

Operation Manual. Turboflotor 5000 SHORTY

AUTOMATIC SUBMERSIBLE UTILITY PUMP

GeyserMax-Flow Series

65 Series. Valve Operation Manual

G E N E S I S S T O R M SPECIALIZED TOP OFF AND REPLENISHMENT MODULE

Professional Series 1/2HP 2 YEAR WARRANTY CONVERTIBLE JET PUMP REPAIR PARTS

APOLLO Gate Operators, Inc.

ELECTRIC FUEL PUMPS P/N , , & FUEL PRESSURE REGULATOR P/N

GARDEN HOSE UTILITY PUMP

Turboflotor multi SL

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

PeroxiDraw Dispenser

TABLE 1-1 GPM FLOW RATE PROPORTIONER, 1/4 I.D. TUBING Injection Rates For Viscosities Shown Metering Tip Color

Electric Vehicle Charging Station

LED NEON FLEX INSTALLATI ON GUI DE

PRE-PLUMBED SEWAGE SYSTEM

MAC FAUCETS. FA400 Wall Mount Sensor

SKV40. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 2" Solids: 2" GPM: TDH:

HYPPOETL HYPPO DUALETL 12 VOLT DC Swing Gate Operator

WARNING! Buyer/user assumes all responsibility for safety and proper use not in accordance with the directions and safety labels.

40 V LITHIUM-ION BATTERY ATTACH YOUR RECEIPT HERE AB13786C 1. kobalttools.com ITEM # /

Installation, Operating and Maintenance instructions for Hydro-Air pumps

Installation, Operation and Maintenance Manual

INSTRUCTION MANUAL G-Surge Tank #40007, #40008 & #40009

D Instructions/Parts. Siphon Feed Detail Spray Gun D

Geo Arch Single Lever Pull-Down Kitchen Faucet With Soap Dispenser

WARNING! Buyer/user assumes all responsibility for safety and proper use not in accordance with the directions and safety labels.

MGFHVLP. Instructions/Parts. Mini Gravity Feed System E. Part No Includes MGFHVLP Mini Gravity Feed Spray Gun and MGC 125 Gravity Cup.

Packaged Pump Sets FOR DIESEL FUEL OIL APPLICATION. Packaged Pump Sets for Diesel/Fuel Oil Application Page 1

Installation Manual. Automated Fuel. Maintenance. System FUEL TECHNOLOGIES INTERNATIONAL LLC

AEROMOTIVE Part # Fuel System Prime Kit INSTALLATION INSTRUCTIONS

Installation Manual. CS9300 Professional Series Landscape Lighting System

AEROMOTIVE Part # Ford 5.0 Liter INSTALLATION INSTRUCTIONS

Submersible Waterfall Pump 1250 Gallons Per Hour

GV Standard 3 Wall Box Operation and Maintenance Manual

DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131

I Button Chemical Dispenser. Overview. Installation Instructions

INSTALLATION INSTRUCTIONS MODELS S S SHALLOW WELL & CONVERTIBLE JET PUMPS PAGE 3 PAGE 8

Crawford Performance Top Mount Air/Oil Separator Install Instructions Version 1.12

SUBMERSIBLE FILTRATION & WATERFALL PUMP

INSTALLATION INSTRUCTIONS FUEL RAIL

WATERFEATURE PUMP HOTLINE 1300 AQUATEC INSTRUCTION MANUAL VERSION JUNE 2016 MODEL 02PV030 - PV650 02PV050 - PV PV075 - PV PV077 - PV3000

SUBMERSIBLE DIRTY WATER PUMP

Cone Skimmers. Instructions. for Models 75G, 150G and 300G. Please read these instructions in their entirety before attempting to use this product.

Installation Instructions

STEP-BY-STEP INSTALLATION GUIDE

Submersible Waterfall Pump 1200 Gallons Per Hour

HydraPump Submersible Owner s Guide

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

Model T Professional Series 1/2HP 2 YEAR WARRANTY SHALLOW WELL JET PUMP

OPERATION & MAINTENANCE INSTRUCTIONS

PLATINUM Series CAN WIDEBAND CONTROLLER WBC 1 & WBC 2 QUICK START GUIDE (HT & HT059980) Version 4

Installation. Aerada 1200 Series CS Faucet S Battery-Operated Capacitive Sensing Gooseneck Faucet IMPORTANT

Container Fountain Kit with LED Light

Installation Instructions

MAC FAUCETS FA400 WALL MOUNT FAUCETS

INSTALLATION GUIDE AND USER MANUAL

23200 Navigator Dilution Control System 4 Button Model (NAV 4)

BATTERY WASH CABINETS, WASH STATIONS, RECIRCULATION/NEUTRALIZATION SYSTEM

T1-Titanium Non-HVLP Spray Gun

Vertex Omega 180 i Protein Skimmer

Cut zip ties and remove 2 plastic wiring harness brackets.

Certo Chemical Dilution System

Portable Speaker System for Tablets/eReaders/Smartphones

Gate Operators, Inc. Model 7100UL Residential & Medium Duty Commercial Slide Gate Operator INSTALLATION MANUAL

Installation Instructions F-440N. Model No. F F F F F F F /16 157mm. Inline.

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Operation Manual. Turboflotor Protein skimmer for aquaria up to 5000 litres

IN SUMP PROTEIN SKIMMER TOP QUALITY & HIGHLY EFFICIENT INCLUDES NEEDLE WHEEL PUMP 1 YEAR WARRANTY

SKHS SERIES 2 HP 1-1/2 HP 1 HP 1/2 HP CAPACITY-U.S. G.P.M.

Matala. VersiFlow Series. Instruction and Maintenance Manual

Single Lever Pull-Out Kitchen Faucet

advanced FLOW engineering Instruction Manual P/N: Make: RAM Model: Diesel Trucks Year: Engine: L6-6.7L (td)

ProFlo FatBoy

Automatic Gate Openers Gate Opener Accessories

Model: PI-140 Power Inverter Converts 12V DC battery power to 120V AC household power

TeckNet BLUETEK iep517 Power Bank

2 Wire Plus Ground 3 Wire Plus Ground IL0655

OIL SMART PLUG AND PLAY SYSTEM, Model #OSS-100

Transcription:

eflux DC Table of Contents Safety Instructions & Warnings What s Included & Installation eflux DC Installation Warranty & Safety Warnings 5 Thank You! For purchasing our eflux Flow pump. Please read all instructions before getting in the LOOP! Safety Instructions & Warnings IMPORTANT: Please refer to additional safety warnings on last page. - Keep out of reach children. Do not allow children to play with pump, pump Manifold or power supply. - Never run flow pump dry or out of water, do NOT run dry. - Do not submerse more than.5m/4 ft. of water depth. - Always unplug with dry hands for any maintenance or service. - eflux flow pumps are. Ensure one UL transformer is used per wave pump. - Ensure UL transformer is plugged into a GFCI approved outlet with a drip loop. - Do not exceed maximum head pressure or height specification. - ALWAYS follow sump and tank/overflow manufacturer instructions regarding check valves - Turn controller OFF and disconnect pump from power before performing any service. - Ensure eflux flow pumps and any accessories all have a drip loop installed before plugging into the flow pump manifold HUB as shown below. - Only use in freshwater or saltwater applications, do not use pumps in other liquids. om Use only with GFCI Protected AC Outlet DC Ensure correct voltage power supply for each component Power Supply AC Power Ensure use of drip loop for all cables eflux DC SAVE THESE INSTRUCTIONS Page

What s Included Installation Instructions C Each eflux DC Flow pump includes: Item Description Quantity A eflux DC B Rubber Pump Mounts (pre-installed) C 4V DC Transformer, UL Listed D w/microusb Cable E Bracket & Mounting Hardware F Pump Screen Inlet G Inlet/Outlet Fittings F G D A E Installation - READ SAFETY WARNINGS BEFORE INSTALLATION Important - Please visit our website for installation videos at www.current-usa.com B ft. Pump Specifications Max. Max. Max. Item# gph Height Watts Voltage Outlet 6009 050 0.5ft./.m 0 /4" & 600 900 4.75ft./4.5m 55 /4" & " 60 70 0ft./6m 80 /4" & " *Note: threaded PVC fittings are not recommended, but are compatible on some pumps. If using PVC fittings do not overtighten and ensure teflon tape is used. Head Pressure 8 ft. 5 ft. ft. 9 ft. 6 ft. ft. Model 600 Max Watts: 55 Model 6009 Max Watts: 0 Model 60 Max Watts: 80 500 gph 500 gph 000 gph 500 gph 000 gph 000 gph 89 lph 785 lph 5670 lph 7570 lph 946 lph,56 lph Flow Rate Plumbing the eflux DC Flow pump The eflux DC flow pump can be installed either submersible (internal) or inline (external). If using in a submersible application, please use the inlet pump screen (included). Submersible External Inline Page

Installation eflux DC NOTE: Please ensure to follow your aquarium tank and sump/filter manufacturer instructions regarding the minimum size requirement of your sump and if a check valve is required. Installing Pump Submersible (internal) Installation Step. Thread pump filter screen to inlet of the pump. Step. Place 0-ring inside the outlet barb fitting and quick coupling. Thread barb fitting to pump and hand tighten. Step. Connect return hose (not included) by sliding over barb fitting. Ensure hose is secured using a hose clamp (not included). Step 4. Fill sump with water and check for water/air leaks. Inline (external) Installation Step. Place o-ring inside the inlet barb fitting and quick coupling. Thread barb fitting to pump inlet and hand tighten. Step. Place o-ring inside the outlet barb fitting and quick coupling. Thread barb fitting to pump outlet and hand tighten. Step. Connect inlet hose (not included) by sliding over inlet barb fitting. Ensure hose is secured by using a hose clamp (not included.) Connect return hose to outlet barb fitting and secure with clamp. Step 4. Fill sump with water and check for water/air leaks. Installing Step. Choose a location underneath your aquarium cabinet free of excessive moisture and/or saltwater. If connecting to another manifold HUB, ensure distance between HUBs is -4. Step. Using included wood mounting screws, mount the eflux flow pump HUB mounting bracket to stand. Slide flow pump manifold HUB into bracket. Wood Screws Manifold HUB Mounting Bracket Store Cap Remove Cap Store Cap Note: Remove and store the silicone caps on the manifold HUB mounting bracket. Keep caps in place when not using other ports for protection. Page

Installation Pump Power DC Input Pump Connection Pump Dial Flow Control Step. Plug power supply into DC input on manifold HUB. Installation Instructions Important: Before connecting all of the components together, please review the following specifications in regards to the and appropriate connections. Communication LED Indicator Lights E Specifications: Pump DC Inputs: Voltage: Max. DC Input per Channel: 0w@ Max. DC Output per Channel: 80w@ P Indicator LEDs: D C A (Blue)= Indicates 050 gph pump is connected B B (Blue)= Indicates 900 gph pump is connected Port# A C (Blue)= Indicates 70 gph pump is connected Port# D (Blue)= Feed - flashes when pump is in feed mode Port#4 Port# E (Red)= Active feedback/pump status: MicroUSB Ports (all for communication) Red Solid - indicates pump is operating normal Red Flashing - indicates non-normal operation Connecting Pump to (pump running dry, over voltage over/under voltage, over temperature) Step. Plug DC pump cable into pump connection on manifold HUB. Step. Red LED status light should turn solid red. Adjust flow from 0-00% using dial until flow rate is acheived. NOTE: eflux DC pumps have a slow ramp to speed, allow pump to run for 0-5 seconds for pump to reach adjusted flow. AC Power Transformer Connect to DC Input Connect to Pump Input P P P To other LOOP S Note: FEED mode will only operate when DC pump is plugged into a manifold HUB with an Orbit IC controller, eflux wave pump controller or the HUB is controlled via Bluetooth. When in FEED mode, DC flow pump will ramp down to 0% flow for 0 minutes, then ramp to normal speed. Pump Maintenance **Important - Due to harsh conditions found around marine aquariums, it is important to perform the following pump maintenance every 6 months. When performing any maintenance or service, ensure pump is disconnected from power and manifold HUB.. Remove pump from service by disconnecting power and removing pump from sump via disconnect fittings.. Carefully remove front pump cover, o-rings and slide impeller from pump. Use a small soft brush and running freshwater to clean any organic debris. If any calcium deposits have developed, soak the components in mild vinegar/freshwater solution. DO NOT use strong acids.. Re-assemble pump, reconnect fittings with all o-rings properly in place and reconnect power. Page 4

Warranty Information Safety Warnings and Warranty P P P Drip Loop Drip Loop Current-USA One Year Limited Warranty This product MUST be purchased from an authorized Current-USA reseller. Visit our website for a list of unauthorized resellers. Current USA, Inc. warrants this product against defects in materials and worksmanship for ONE () YEAR from the date of original retail purchase and is not transferable. lights. Do not install pumps where strong currents can harm animals. Do not install close to sand bed where it can suck/stir sand. Pumps can produce powerful wave action in both wave and surge modes. Ensure your aquarium is designed for wave pumps and ensure pumps are mounted low enough not to push water out of the aquarium tank. Magnet assembly is VERY powerful. Be cautious not to cause injury to fingers. Keep magnets and all accessories out of reach of children. Never place magnets or pump near sensitive electronics, sharp objects or other attractive surfaces. Do not run pumps dry or out of water. Always place spacer between magnets when not in use. Always unplug with dry hands for maintenance or servicing. Turn all controllers OFF and disconnect power supply before performing any service or maintenance. This product MUST be powered by a UL or ETL listed power supply. To avoid possible electric shock, power supply MUST be plugged into a GFCI wall outlet installed by a certified electrician in accordance with all local codes. All products must have a drip loop. Page 5 DC