HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS

Similar documents
VALVES POWER TRANSMISSION T E C H N I C A L C A T A L O G

MK23 MKE23 COMPACT MOTORS T E C H N I C A L C A T A L O G

MSE03 HYDRAULIC MOTORS T E C H N I C A L C A T A L O G

MKD04 COMPACT MOTORS

MK09 COMPACT MOTORS T E C H N I C A L C A T A L O G

CDM CREEPDRIVE MOTOR

MG02 - MGE02 STEERABLE WHEEL MOTORS T E C H N I C A L C A T A L O G

MK18 MKE18 COMPACT MOTORS

MW50 HYDRAULIC MOTORS

MK05 COMPACT MOTORS T E C H N I C A L C A T A L O G

MOTORS M HYDRAULIC MOTORS

MI250 HYDRAULIC MOTORS T E C H N I C A L C A T A L O G

MS02 - MSE02 HYDRAULIC MOTORS

MK05 COMPACT MOTORS T E C H N I C A L C A T A L O G

MS25 HYDRAULIC MOTORS T E C H N I C A L C A T A L O G

MK35 COMPACT MOTORS T E C H N I C A L C A T A L O G

MS35 HYDRAULIC MOTORS

ELECTRIC COMPONENTS HYDRAULIC COMPONENTS

MZ05 - MZE05 HYDRAULIC MOTORS

6/2 WAY DIRECTIONAL VALVE KV (NG 6)

MS02-MSE02 HYDRAULIC MOTORS T E C H N I C A L C A T A L O G

MOTORS MV HYDRAULIC MOTORS T E C H N I C A L C A T A L O G

MZ02 - MZE02 HYDRAULIC MOTORS T E C H N I C A L C A T A L O G

TPV Variable Displacement Closed Loop System Axial Piston Pump HY-TRANS THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 501 / 1009 / E

PMV0 VARIABLE DISPLACEMENT PUMP CLOSED LOOP CIRCUIT T E C H N I C A L C A T A L O G

MS50 HYDRAULIC MOTORS T E C H N I C A L C A T A L O G

Axial Piston Pump Series PV Design 45 Variable Displacement. Catalogue HY /UK February 2007

AXIAL PISTON PUMPS VARIABLE DISPLACEMENT

Variable displacement axial piston pump type V30D

VARIABLE PUMPS FOR CLOSED LOOP OPERATION type HV-02

TPV Variable Displacement Axial Piston Pumps CONTENTS. General Information. Installation Instructions. Technical Specifications 6-7

Hydraulic Pump Series VP1 Variable Displacement

PM50 VARIABLE DISPLACEMENT PUMP CLOSED LOOP CIRCUIT T E C H N I C A L C A T A L O G

MZE03 HYDRAULIC MOTORS

Series 20 Axial Piston Pumps. Technical Information

AP212HP Cast Iron Gear Pumps

VALVES RANGE FOR OPEN LOOPS T E C H N I C A L C A T A L O G

Hydraulic Pump Series F1plus Fixed Displacement

THE PRODUCTION LINE OF PONAR WADOWICE

Series 20 Axial Piston Pumps. Technical Information

TPV Variable Displacement Closed Loop System Axial Piston Pump MANUFACTURING THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 403 / 1110 / E

VED*M PROPORTIONAL PILOT OPERATED DIRECTIONAL CONTROL VALVES

unrestricted; preferably with coil at bottom (auto. air bleed) 12 or 24 Volt DC from an electronic controller Deutsch plug - IP67

AXIAL PISTON PUMPS SHPV SECTIONAL VIEW

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min

DSE /117 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 11 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min

Proportional Directional Control Cartridge Valves: PSV10-34 & PSV12-34

VINCKE HYDRAULIC PUMPS

Axial piston variable pump A4VG Series 32. Europe. RE-E Edition: Replaces:

Available manual, pneumatic, and hydraulic spool control kits.

TPV 4000 (EX 28-41) Variable Displacement Closed Loop System Axial Piston Pump HY-TRANS THE TRANSMISSION LINE OF HANSA-TMP HT 16 / M / 280 / 1008 / E

PM45 VARIABLE DISPLACEMENT PUMP CLOSED LOOP CIRCUIT T E C H N I C A L C A T A L O G

6/2 ways/positions flow diverters L (VS151-VS152-VS155)

Fluid Cooling Industrial COLW Series

AXIAL PISTON MOTORS SHMF

Axial Piston Variable Double Pump A8VO

3/2 ways/positions flow diverters L (VS91-VS92-VS95)

Solenoid valve VDHT standard BSP (British Standard Pipe)

TPV 1000 (Ex 6-18) Variable Displacement Closed Loop System Axial Piston Pump HY-TRANS THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 109 / 1008 / E

Heavy Duty Hydrostatic Transmissions

RV1P /118 ED VARIABLE DISPLACEMENT VANE PUMPS SERIES 10 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

PM25 VARIABLE DISPLACEMENT PUMP CLOSED LOOP CIRCUIT T E C H N I C A L C A T A L O G

DIRECTIONAL CONTROL VALVE SOLENOID OPERATED TYPE HD3-ES-*-/10 CETOP MPa HD3 - ES - (1) (C) - * - (024C) (-) / 10

DSE3B /118 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 10 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Gear Pumps / Motors. Series PGP / PGM Fixed Displacement Pumps, Cast-Iron and Aluminium Designs

Truck Hydraulics. Serie VP1 Variable Displacement Pumps

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 851 / 0813 / E

Proportional Valves. Proportional solenoid valves for pressure and flow control

Flow direction is reversed by tilting the swash plate to the opposite side of the neutral or zero displacement position.

3/2-way Solenoid Valve for pneumatics

Contents. Directional Control Valve 2 Series CV 300

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min

Differential Lock Valve

GPM PSI LPM BAR MODEL CAVITY PAGE IF-S3A special IF-S3D special IG-S4A special 198

PM10 VARIABLE DISPLACEMENT PUMP CLOSED LOOP CIRCUIT T E C H N I C A L C A T A L O G

Hydraulics. Axial Piston Pumps Series PVP. Introduction. With thru shaft option for multiple pump options Swash plate type for open circuit

Axial Piston Variable Pump AA4VG

Axial piston variable displacement pump type V60N, Serie 03

PISTON MOTORS FOR CLOSED LOOP SYSTEMS types HMF/A/V/R-02

UŽSISAKYKITE internetu telefonu el. paštu

Servo solenoid valves with on-board electronics (OBE)

HYDRAULICS VINCKE HYDRAULIC PUMPS

PM25 VARIABLE DISPLACEMENT PUMP CLOSED LOOP CIRCUIT T E C H N I C A L C A T A L O G

SV SOLENOID OPERATED

Directional Control Valve Series D3W Soft Shift

4/2 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback

Axial piston variable pump (A)A4VSO

V Series AXIAL PISTON PUMP ORDER CODE

BW0511FP. ByWire Elements BW0511FP Flow Sharing Element Interface IBW0511

M7X / M7V Series. Swash Plate Type Axial Piston Motor. Precision Machinery Company

Flow sharing control block in mono block / sandwich plate design M6-22

P2060 P2075 P2105 P2145 P3105 P3145

AXIAL PISTON PUMPS SHPV SECTIONAL VIEW

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

6/2 ways/positions flow diverters

EV FT3 ES-FT5 ES/GB :09 Pagina 4 FT3 ES* 4

Post-Compensated Proportional Valve CV2000LS

Pressure Control Valves

Transcription:

HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS T E C H N I C A L C A T A L O G

Hydraulic components POCLAIN HYDRAULICS Methodology : This document is intended for manufacturers of machines that incorporate Poclain Hydraulics products. It describes the technical characteristics of Poclain Hydraulics products and specifies installation conditions that will ensure optimum operation. This document includes important comments concerning safety. They are indicated in the following way: Safety comment. This document also includes essential operating instructions for the product and general information. These are indicated in the following way: Essential instructions. General information. Information on the model number.information on the model code. Weight of component without oil. Volume of oil. Units. Tightening torque. Screws. Information intended for Poclain-Hydraulics personnel. The views in this document are created using metric standards. The dimensional data is given in mm and in inches (inches are between brackets and italic) 2 11/04/1

POCLAIN HYDRAULICS CONTENT Hydraulics Components HYDRAULIC BLOCKS 4 Bypass electro-valve block 4 Displacement shift valve block 6 Exchange valve 8 Exchange block safety with relief valve 10 Traction control (in-line) valve 12 Traction control (flanged) valve 14 Relay valve 16 Flow divider FDB 20 18 Flow divider FDB 25 28 Pressure relief valve VPLB15 9 Adjustable pressure limiter VPB25 42 Free-wheeling valve H25 44 Free-wheeling valve H15 46 Directional control valve VD 2V 2H20/H25 48 Directional control valves VD V 2H 20/25 50 Two position control valve VD 1V 2B5L 52 Two position control valve VD 2V 2B5 L 54 Two position control valve VD V 2B5L 56 Directional control valves VDP 58 OTHER COMPONENTS 62 Other hydraulic components Hydraulic blocks 12/04/1

HYDRAULIC BLOCKS Hydraulic components POCLAIN HYDRAULICS BYPASS ELECTRO-VALVE BLOCK Function: Control cylinder bypass for a pump or tandem pump swash plate. Commercial Description Part number Compatibility Hydraulic symbol EV-CED10D51A20NG2 BLOCK 0048418B Transmissions with combined integrated braking systems. Caracteristics Maximum flow rate Response time Internal leakage at 200 bars [2900 PSI] Operating temperature range Voltage Electrical interface Power Mass 40 L/min [10.57 GPM] Time to energize: 40/80 ms Time to de-energize: 0/70 ms 80 cm³ / min max. [max. 4.88 cu in/min] - 40 C to + 100 C [- 40 F to 212 F] 12 V DC ISO 4 400 / DIN 4 650 (IP 65) See CDE SA CONNECTOR KIT (brochure A01889D) 26 W [0.05 HP] 0. kg [0.6 lb] 4 12/04/1

POCLAIN HYDRAULICS Hydraulic components Pressure drop With oil HV46 to 50 C [122F] GPM L/min Dimensions Installation Block mounting position: Indifferent. Chassis mounting: Ref. Quantity Class N.m [lb.ft] ± 10 %(as per standard DIN 912) 1 M 6 2 8.8 10 [7.7] Hydraulic connections (for a tandem pump) : Electrical control by the brake valve when actuated Pump 1 plate cylinder control Pump 2 plate cylinder control* * When only one pump is used, the two unused orifices are plugged. Other hydraulic components Hydraulic blocks Port Function Connection 1-2 Pump displacement control Ø 17 Gaz Cyl -4 Displacement control of [G /8''] other pump (UNF: Please contact us) Max pressure N.m [lb.ft] ± 10 % 00 [4 51] 100 [1 450] in use 55 [41] 12/04/1 5

Hydraulic components POCLAIN HYDRAULICS DISPLACEMENT SHIFT VALVE BLOCK Function: Controls displacement shift for MW motors and release of parking brakes. Commercial Description BLOC VALVE AVEC REPARTITION Designed for motors: MW24 MW14 Part number 0064609U R00270015U Compatibility SPEED + Transmission systems. Hydraulic symbol ev1 S ev2 Y ev Y1 ev4 D ev5 D1 MW14 MW24 T P Features Voltage 12 V DC Electrical interface ISO 4400 / DIN 4650 (IP 65).See CDE SA CONNECTOR KIT. Power 52 W [0.07 HP] MassMass 20 kg [44.1 lb] ElectrovalveSolenoid valve ev1 ev2 - ev - ev4 - ev5 Pressure drop Flow L/min [GPM] Function Parking brake control Motor displacement control Power 52 W [0.07 HP] W [0.044 HP] Never drive the vehicle when the parking brake is engaged. 6 12/04/1

POCLAIN HYDRAULICS Hydraulic components Dimensions of valve bloc for 4 displacements motor MW24 Dimensions of valve bloc for displacements motor MW Installation Valve mounting position: Indifferent. This block must be protected from water spray, or its solenoids will be affected. Chassis mounting: Thread depth Ref. Quantity Class mm [in] N.m [lb.ft] ± 10 % M 8 2 8.8 1 [0.51] 25 [18.4] M 6 4 8.8 15 [0.59] 10 [7.4] Other hydraulic components Hydraulic blocks Hydraulic connections: Connection Max pressure Port Function Metric SAE N.m [lb.ft] ± 10 % P Supply M 22 x 1.5 Contact us 0 [45] 100 [74] S Parking brake T Tank M 27 x 2 Contact us 1 [14] 200 [148] Y - Y1 D - D1 Motor displacement control M 18 x 1.5 Contact us 0 [45] 70 [52] Recommended : A mechanical locking of the electric control in order not to change displacement by mistake. A LED indicating activation/deactivation of the parking brake. 12/04/1 7

Hydraulic components POCLAIN HYDRAULICS EXCHANGE VALVE Function: In a closed circuit, takes oil from the low pressure side and routes it to the coolant. Commercial Description Part number depends on relief valve setting Compatibility Hydraulic symbol EXCHANGE VALVE 16 bar [22 PSI] : 0048472K 22 bar [19 PSI] : 00442N 0 bar [45 PSI] : 004421B All types of transmission Caracteristics Mass 7.8 kg [17.19 lb] Opening range BE 0 bar [45 PSI] BE 22 bar [19 PSI] BE 16 bar [22 PSI] P bar P PSI L/min GPM 8 12/04/1

POCLAIN HYDRAULICS Hydraulic components Dimensions Installation Valve mounting position: Chassis mounting : Ref. Quantity Class 1 Hydraulic connections : Indifferent. Thread depth mm [in] N.m [lb.ft] ± 10 % (as per standard DIN 912) M 8 4 8.8 1 [0.51] 25 [18.4] Max pressure Port Function Connection N.m [lb.ft] ± 10 % A HP connection M 27 x 2 420 [6 100] 200 [148] B HP connection T Tank connection M 22 x 1.5-100 [74] 7/16-20 UNF 2B 420 [6 100] 20 [15] M1 Pressure measurement (A) M2 Pressure measurement (B) Other hydraulic components Hydraulic blocks 12/04/1 9

Hydraulic components POCLAIN HYDRAULICS EXCHANGE BLOCK SAFETY WITH RELIEF VALVE Function: In a closed circuit, takes oil from the low pressure side of the circuit where the exchange valve keeps a minimum pressure of 22 bars, and routes it to the cooler. Commercial description Part number depends on relief valve setting Compatibility Hydraulic symbol BLOC BEHS + E 22 bar [19 PSI] : 00441M All types of transmission For others setting values, consult your Poclain Hydraulics sales engineer. Caracteristics Mass 11.5 kg [22.5 lb] Opening range P bar P PSI L/min GPM 10 11/04/1

POCLAIN HYDRAULICS Hydraulic components Dimensions Installation Valve mounting position: Chassis mounting : Indifferent. Ref. Quantity Class N.m [lb.ft] ± 10 % (as per standard DIN 912) 1 Hydraulic connections: M 8 4 8.8 25 [18.4] Port Function Connection Max pressure N.m [lb.ft] ± 10 % A HP connection M 27 x 2 420 [6 100] 200 [148] B HP connection T Tank connection M 22 x 1.5-100 [74] M1 Pressure measurement (A) 420 [6 100] M2 Pressure measurement (B) 7/16-20 UNF 2B 20 [15] M LP Pressure measurement 22 [20] Other hydraulic components Hydraulic blocks 11/04/1 11

Hydraulic components POCLAIN HYDRAULICS TRACTION CONTROL (IN-LINE) VALVE Function: Proportional Flow Control Valve used to regulate a control wheel slip. Flow / voltage Q < 20 L/min [5.2 GPM] 20 [5.2 GPM] < Q < 50 L/min [1.2 GPM] 12 V 24 V 12 V 24 V Commercial Description VMA-020-T1-12-00 VMA-020-T1-24-00 VMA-050-T1-12-00 VMA-050-T1-24-00 Part number 0048425J 0048448J 0048426K 0048447H Compatibility Electronic transmission management Hydraulic symbol Pressure drop GPM P bar P PSI L/min The valves must be supplied in G with a pressure between 15 and 0 bar [217 PSI and 45 PSI]. Maximum flow, from P to A or B, for a fully open valve, is 120 l/min [1.7 GPM] per wheel with a pressure difference ( P) of 5 bar [72 PSI] (96 cst mineral oil at 25 C [77 F]). 12 12/04/1

POCLAIN HYDRAULICS Hydraulic components Dimensions Installation Valve mounting position Chassis mounting Horizontal. Ref. Quantity Class N.m [lb.ft] ± 10 % (as per standard DIN 912) 1 M 10 2 8.8 49 [6] Motor and valve drain piping must be connected directly to the tank. Hydraulic connections Port Function Connection Standards Max pressure N.m [lb.ft] ± 10 % P HP connection Bride DN 25 PN 400 ISO 6 162 ISO 9 974-1 450 [6 526] 90 [66] A-B HP connection M 27 x 2 450 [6 526] 200 [148] F Drain M 14 x 1.5 1 [14] 45 [] ISO 9 974-1 G LP supply M 14 x 1.5 15 [217] P < 0 [45] 45 [] M1-M2 Pressure measurement M 14 x 1.5 0 P < 20 bar [290] 45 [] Other hydraulic components Hydraulic blocks Electrical connections on E1 and E2: KIT CONNECT VMA VALVE. (See Technical Catalog Mobile Electronic A01889D) 12/04/1 1

Hydraulic components POCLAIN HYDRAULICS TRACTION CONTROL (FLANGED) VALVE Function: Proportional Flow Control Valve used to regulate a control wheel slip. Flow / voltage Q < 20 L/min [5.2 GPM] 20 [5.2 GPM] < Q < 50 L/min [1.2 GPM] 12 V 24 V 12 V 24 V Commercial Description VMA-020-F0-12-00 VMA-020-F0-24-00 VMA-050-F0-12-00 VMA-050-F0-24-00 Part number 0048427L 0048450L 0048428M 0048449K Compatibility Electronic transmission management Hydraulic symbol Pressure drop GPM P bar P PSI L/min The valves must be supplied at G with a pressure of between 15 and 0 bar [217 PSI and 45 PSI]. Maximum flow, from P to A or B, for a fully open valve, is 120 l/min [1.7 GPM] per wheel with a pressure difference ( P) of 5 bar [72 PSI] (96 cst mineral oil at 25 C [77 F]). 14 12/04/1

POCLAIN HYDRAULICS Hydraulic components Dimensions Installation Valve mounting position Remove the protection plate. Make sure that the O-rings are correctly positioned. Install the valve on the mounting face with help from the lug. Chassis mounting Horizontal. Quantity Class N.m [lb.ft] ± 10 % (as per standard DIN 912) M12 4 8.8 86 [6.5] Hydraulic connections Port Function Connection Max pressure Standards N.m [lb.ft] ± 10 % P HP connection DN 25 PN 400 ISO 6 162 ISO 9 974-1 450 [6 526] 90 [66] A-B HP connection M 27 x 2 450 [6 526] 200 [148] F Drain M 14 x 1.5 1 [14] 45 [] G LP supply M 14 x 1.5 ISO 9 974-1 15 [217] P < 0 [45] 45 [] M1-M2 Pressure measurement M 14 x 1.5 0 P < 20 bar [290] 45 [] Lug Height Other hydraulic components Hydraulic blocks Electrical connections on E1 and E2: KIT CONNECT VMA VALVE. (See Technical Catalog Mobile Electronic A01889D) Motor and valve drain piping must be connected directly to the tank. 12/04/1 15

Hydraulic components POCLAIN HYDRAULICS RELAY VALVE Function: Relay Valve is a -way valve with an external hydraulic control. The VS - Relay Valve supplies and drains high volume brakes by connecting accumulate to service brakes on large machines main use : braking systems. Commercial Description Part number Compatibility Hydraulic symbol VS-VALVE RELAIS 70 L/min V2 R00260000J All types of circuit Caracteristics Mass 2.5 kg [5.5 lb] Max. flow 70 L/min [18.5 GPM] Reaction time < 1.4 s Leakage < 0.024 L/min [< 0.006 GPM] Operation temperature -4 C to 120 C [24.8 F to 248 F] Fluid Mineral oil Filtered 10 µm Pressure drop Pressure drop U T P bar P PSI L/min GPM 16 12/04/1

POCLAIN HYDRAULICS Hydraulic components Pressure drop Pressure drop P U P bar P PSI L/min GPM Dimensions Installation Valve mounting position Indifferent Chassis mounting Ref. Quantity Class N.m [lb.ft] ± 10 % (as per standard DIN 912) M6 2 8.8 10 [7.4] 1 Other hydraulic components Hydraulic blocks Hydraulic connections Port Function Connection Quick Return Valve P input Quick Return Valve M22 x 1.5 U output pressure 210 max. [max. 046] N.m [lb.ft] ± 10 % (as per standard DIN 912) 100 [74] A Control pressure M14 x 1.5 45 [] T output tank M22 x 1.5 <1 [<14.5] 100 [74] 12/04/1 17

Hydraulic components POCLAIN HYDRAULICS FLOW DIVIDER FDB 20 Up to 450 Bar [6527 PSI] Up to 150 l/min [9,6 GPM] Direct in-line mounting. Threaded connections to ISO 1179 (BSPP/Gas), ISO 11926 (UNF). FDB 20-2 Operation The bidirectionnal flow divider controls the speed between wheels of the same axle or between different axles by dividing or combining the flow. The flow divider is equipped with an electric or hydraulic controlled by-pass and can be used in open or closed loop circuits. Hydraulic symbol HP valve, solenoid valves and electric by-pass If you have to add a flushing valve in a closed loop circuit equipped with a flow divider, you have to install the flushing valve between the pump and the flow divider. Features Max. pressure Bar [PSI] 450 [6527] By-pass mini. piloting pressure Bar [PSI] 8 [116] Max. flow in by-pass mode Mass Surface treatment l/min [GPM] kg [lbs] Ratio 50/50 150 [9,62] Ratio 60/40 125 [,02] Ratio 70/0 110 [29,05] Ratio 75/25 100 [26,41] Ratio 80/20 95 [25,09] without valves 8,50 [18,74] with HP valve 9,00 [19,84] with HP valve and solenoid valves 11,2 [24,70] Zinc Chromate HP valve and hydraulic by-pass P: High pressure A and B: Outlet T: Drain G1: Preferential charge pressure G2: Plugged charge pressure Pil: Hydraulic control F1, F2 and F: Solenoid valves Hydraulics connections: See Model Code 18 12/04/1

POCLAIN HYDRAULICS Hydraulic components Pressure drop in by-pass mode Test conditions : HV 46 hydraulic fluid at 40 C [104 F] Pressure drop in divider mode Test conditions : HV 46 hydraulic fluid at 40 C [104 F] Division accuracy Test conditions : P of 150 bar [2 175 PSI] betwen outlets. No transfer restrictor. HV 46 hydraulic fluid at 40 C [104 F]. Transfer restrictor Transfer restrictor is located between the outlets A and B. % accurancy deviation % of input flow (Qp,c) Optimal work zone % of controlled flow on input P (Qp,c) % controlled flow on input P (Qp,c) * Standard values ** On request, after validation of your application Other hydraulic components Hydraulic blocks Pressure drop in charge check valve Flow (L/min) P = 5 bar [72.52 PSI] for a flow of 20 L/min (between A or B and G1) P= up to 0 bar [45 PSI] for a flow of 20 L/min (between A or B and G2) 12/04/1 19

Hydraulic components POCLAIN HYDRAULICS Dimensions without valves and with electric by-pass T 4 5 D 4 V 4 P F D B 2 0 2 - - - E 0 - - 0 0 B C - - - S - - - Orifices P Max. pressure Mini. Pressure - A-B 450 [6526] - T 1 [14,5] - G1 0 [45] 8 [116] Hydraulic connections: See Model Code 20 12/04/1

POCLAIN HYDRAULICS Hydraulic components Dimensions with HP valve and electric by-pass T 4 5 D 4 V 4 P F D B 2 0 2 - - - E 0 - - 4 5 B C - - - S - - - Orifices P Max. pressure Mini. Pressure - A-B 450 [6,526] - T 1 [14,5] - G1 0 [45] 8 [116] Hydraulic connections: See Model Code Other hydraulic components Hydraulic blocks 12/04/1 21

Hydraulic components POCLAIN HYDRAULICS Dimensions with HP valve and hydraulic by-pass T 4 5 D 4 V 4 P F D B 2 0 2 - - - H 0 - - 4 5 B C - - - S - - - Orifices P Max. pressure Mini. Pressure - A-B 450 [6,526] - T 1 [14,5] - G1 Pil 0 [45] 8 [116] Hydraulic connections: See Model Code 22 12/04/1

POCLAIN HYDRAULICS Hydraulic components Dimensions with HP valve, solenoid valves and electric by-pass T 4 5 D 4 V 4 P F D B 2 0 2 - - - E - - 4 5 B C - - - S - - - Orifices P Max. pressure Mini. Pressure - A-B 450 [6,526] - T 1 [14,5] - F1 F2-0 [45] F G1 8 [116] Hydraulic connections: See Model Code Other hydraulic components Hydraulic blocks 12/04/1 2

Hydraulic components POCLAIN HYDRAULICS Dimensions with HP valve, solenoid valves and electric by-pass T 4 5 D 4 V 4 P F D B 2 0 2 - - - E - - 4 5 B C A - - S - - - Orifices P Max. pressure Mini. Pressure - A-B 450 [6,526] - T 1 [14,5] - F1 F2 0 [45] - G1 8 [116] Hydraulic connections: See Model Code 24 12/04/1

POCLAIN HYDRAULICS Hydraulic components Auxiliaries Description A solenoid-operated, way, direct-acting, spool-type, screw-in hydraulic directional valve. Features Operating pressure Bar [PSI] 0 [45] Initial coil current draw at 20 C [68 F] Standard coil: 1.2 amps at 12 V Hydraulic symbol Pressure drop Test conditions : 2 cst/150 SUS oil at 40 C [104 F] Flow (GPM) Flow (l/min) 2 to 1 de-energized to 2 energized Other hydraulic components Hydraulic blocks 12/04/1 25

Hydraulic components POCLAIN HYDRAULICS Model code T D V 4 5 4 4 F D B 2 0 2 Type Bidirectional B Size (Flow in by-pass mode) l/min [GPM] 0 to 150 [0 to 40] 20 Bypass With electric control With hydraulic control E H Number of outlets 2 2 Division ratio A/B 50/50 A 60/40 D 70/0 B 75/25 E 80/20 C Max. flow always go through port A. Auxiliaries Without 0 1 solenoid valve 1 2 solenoid valves 2 solenoid valves Transfer restrictor mm [Zoll] Without 00 Diameter 0,6 [0,026] 06 Diameter 0,8 [0,015] 08 Diameter 1,0 [0,094] 10 Contact us for other diameters. Flow in division mode Optimum flow l/min [GPM] Max. flow l/min [GPM] 10 [2.6] 20 [5.] 02 20 [5.] 40 [10.6] 04 0 [7.9] 60 [15.8] 06 40 [10.5] 80 [21.0] 08 50 [1.2] 100 [26.4] 10 Optimal work zone is located between 40% and 60% of max. divided flow. 26 12/04/1

POCLAIN HYDRAULICS Hydraulic components P C S Charge valves Without With HP valves * Without 00 80 Bar [5511 PSI] 8 420 Bar [6091 PSI] 42 450 Bar [6526 PSI] 45 A B * Pressure of valve P = absolute pressure - charge pressure ( P between A or B and G) Hydraulic connections Standard P A-B T G G1 G2 Pil F1-F2-F ISO 1179-1 /4 BSP 1/2 BSP 1/4 BSP* - /8 BSP 1/4 BSP* 1/4 BSPP 1/4 BSP ISO 11926-1 1 1/16-12 UNF 7/8-14 UNF /4-16 UNF - /4-16 UNF /4-16 UNF 9/16-18 UNF 9/16-18 UNF A * /8 BSP from 2 solenoid valves (including by-pass) Options Without 0 Number plate specific to the customer P Electric connections Without 0 Wires 1 Packard 2 Deutsch DIN 4 650 (Hirschmann) 4 AMP (6, x 0,8) 5 Voltage Without 0 12 V 1 24 V 2 Other hydraulic components Hydraulic blocks 12/04/1 27

Hydraulic components POCLAIN HYDRAULICS FLOW DIVIDER FDB 25 Up to 450 Bar [6527 PSI] Up to 00 l/min [79,2 GPM] Direct in-line mounting. Direct mounting on the pump. Threaded connections to ISO 1179 (BSPP/Gas), ISO 11926 (UNF). FDB 25-2 Operation The bidirectionnal flow divider controls the speed between wheels of the same axle or between different axles by dividing or combining the flow. The flow divider is equipped with an electric or hydraulic controlled by-pass and can be used in open or closed loop circuits. Hydraulic symbol HP valve, solenoid valves and electric by-pass If you have to add a flushing valve in a closed loop circuit equipped with a flow divider, you have to install the flushing valve between the pump and the flow divider. Features Max. pressure Bar [PSI] 450 [6527] By-pass mini. piloting pressure Bar [PSI] 8 [116] Max. flow in by-pass mode Mass Surface treatment l/min [GPM] kg [lbs] Ratio 50/50 00 [79,25] Ratio 70/0 215 [56,79] Ratio 80/20 190 [50,19] without valves 14,0 [0,86] with HP valve 15,0 [,06] with HP valve and solenoid valves 18,2 [40,12] Zinc Chromate HP valve and hydraulic by-pass P: High pressure A and B: Outlet G: charge pressure T: Drain Pil: Hydraulic control F1, F2 and F: Solenoid valves P1, M1 and M2: pressure measurements Hydraulics connections: See Model Code 28 12/04/1

POCLAIN HYDRAULICS Hydraulic components Pressure drop in by-pass mode Test conditions : HV 46 hydraulic fluid at 40 C [104 F] Pressure drop in divider mode Test conditions : HV 46 hydraulic fluid at 40 C [104 F] Division accuracy Test conditions : P of 150 bar [2 175 PSI] betwen outlets. No transfer restrictor. HV 46 hydraulic fluid at 40 C [104 F]. Transfer restrictor Transfer restrictor is located between the outlets A and B. % accurancy deviation % of input flow (Qp,c) Optimal work zone % of controlled flow on input P (Qp,c) % controlled flow on input P (Qp,c) * Standard values ** On request, after validation of your application Other hydraulic components Hydraulic blocks Pressure drop in charge check valve Flow (L/min) P = 5 bar [72.52 PSI] for a flow of 20 L/min (between A or B and G1) P= up to 0 bar [45 PSI] for a flow of 20 L/min (between A or B and G2) 12/04/1 29

Hydraulic components POCLAIN HYDRAULICS Dimensions without valves and with electric by-pass T 4 5 D 4 V 4 P F D B 2 5 2 - - - E 0 - - 0 0 B C - - - S 0 0 0 Orifices Max. pressure Mini. Pressure P - A-B - M1 450 [6526] - M2 - P1 - T 1 [14,5] - G 0 [45] 8 [116] Hydraulic connections: See Model Code 0 12/04/1

POCLAIN HYDRAULICS Hydraulic components Dimensions without valves and with hydraulic by-pass T 4 5 D 4 V 4 P F D B 2 5 2 - - - H 0 - - 0 0 B C - - - S 0 0 0 Orifices Max. pressure Mini. Pressure P - A-B - Pil - 450 [6526] M1 - M2 - P1 - T 1 [14,5] - G 0 [45] 8 [116] Other hydraulic components Hydraulic blocks Hydraulic connections: See Model Code 12/04/1 1

Hydraulic components POCLAIN HYDRAULICS Dimensions with HP valve and electric by-pas T 4 5 D 4 V 4 P F D B 2 5 2 - - - E 0 - - 4 5 B C - - - S 0 0 0 Orifices Max. pressure Mini. Pressure P - A-B - M1 450 [6526] - M2 - P1 - T 1 [14,5] - G 0 [45] 8 [116] Hydraulic connections: See Model Code 2 12/04/1

POCLAIN HYDRAULICS Hydraulic components Dimensions with HP valve, solenoid valves and electric by-pass T 4 5 D 4 V 4 P F D B 2 5 2 - - - E - - 4 5 B C - - - S 0 0 0 Orifices Max. pressure Mini. Pressure P - A-B - M1 450 [6526] - M2 - P1 - T 1 [14,5] - G 8 [116] F1-0 [45] F2 - F - Hydraulic connections: See Model Code Other hydraulic components Hydraulic blocks 12/04/1

Hydraulic components POCLAIN HYDRAULICS Direct mounting on the pump T 4 5 D 4 V 4 P F D B 2 5 2 - - - E - - 4 5 B C - - - S A 0 0 Pump with side ports Pump with twin ports Orifices description: page page 7 4 12/04/1

POCLAIN HYDRAULICS Hydraulic components Auxiliaries Description A solenoid-operated, way, direct-acting, spool-type, screw-in hydraulic directional valve. Features Operating pressure Bar [PSI] 0 [45] Initial coil current draw at 20 C [68 F] Standard coil: 1.2 amps at 12 V Hydraulic symbol Pressure drop Test conditions : 2 cst/150 SUS oil at 40 C [104 F] Flow (GPM) Flow (l/min) 2 to 1 de-energized to 2 energized Other hydraulic components Hydraulic blocks 12/04/1 5

Hydraulic components POCLAIN HYDRAULICS Model code T D V 4 5 4 4 F D B 2 5 2 Type Bidirectional B Size (Flow in by-pass mode) l/min [GPM] 150 to 00 [40 to 80] 25 Bypass With electric control With hydraulic control E H Number of outlets 2 2 Division ratio A/B 50/50 A 70/0 B 80/20 C Auxiliaries Without 0 1 solenoid valve 1 2 solenoid valves 2 solenoid valves Max. flow always go through port A. Transfer restrictor mm [Zoll] Without 00 Diameter 0,6 [0,026] 06 Diameter 0,8 [0,015] 08 Diameter 1,0 [0,094] 10 Contact us for other diameters. Flow in division mode Optimum flow l/min [GPM] Max. flow l/min [GPM] 15 [,9] 0 [7,9] 0 5 [9,2] 70 [18,4] 07 50 [1,2] 100 [26,4] 10 80 [21,1] 160 [42,2] 16 100 [26,4] 200 [52,8] 20 Optimal work zone is located between 40% and 60% of max. divided flow. 6 12/04/1

POCLAIN HYDRAULICS Hydraulic components P C S A Charge valves Without With HP valves * Without 00 80 Bar [5511 PSI] 8 420 Bar [6091 PSI] 42 A B * Pressure of valve P = absolute pressure - charge pressure ( P between A or B and G) Options Without 0 Number plate specific to the customer P Direct mounting on the pump Electric connections Without 0 Wires 1 Packard 2 Deutsch DIN 4 650 (Hirschmann) 4 AMP (6, x 0,8) 5 Voltage Without 0 12 V 1 24 V 2 Hydraulic connections Standard P A-B T G G1 G2 Pil F1-F2-F M1-M2 ISO 1179-1 - - /8 BSP /8 BSP - - /8 BSP 1/4 BSPP 1/4 BSP ISO 6162-2 M screws Flange 1 Flange /4 - - - - - - - ISO 11926-1 - - /4-16 UNF /4-16 UNF - - /4-16 UNF 9/16-18 UNF 9/16-18 UNF ISO 6162-2 UNF screws Flange 1 Flange /4 - - - - - - - ISO 1179-1 - - /8 BSP /8 BSP - - /8 BSP 1/4 BSPP 1/4 BSP ISO 6162-2 UNF screws Flange 1 Flange /4 - - - - - - - A 2 E F Other hydraulic components Hydraulic blocks 12/04/1 7

Hydraulic components POCLAIN HYDRAULICS 8 12/04/1

POCLAIN HYDRAULICS Hydraulic components PRESSURE RELIEF VALVE VPLB15 Up to 15 bar [,045 PSI] Up to 60 L/min [18.5 GPM] Limit creates back pressure in open loop. Limit case pressure in case of free-wheeling. Features Flow rate 70 L/min [20 GPM] Mass kg [7 lb] P-Q Performance curves Diff. pressure VPLB15 Hydraulic symbol Without external drain With external drain Other hydraulic components Hydraulic blocks Flow 12/04/1 9

Hydraulic components POCLAIN HYDRAULICS Dimensions Without external drain With external drain Installation Valve mounting position Indifferent Chassis mounting Ref. Quantity Class Nm [lb.ft] ± 10 % (as per standard DIN 912) 1 M10 2 8.8 50 [7] Hydraulic connections Port Function Connection Pressure 01 Input M 27 x 2 (DIN 852) 1 Output max. 50 [max. 725] Nm [lb.ft] ± 10 % (as per standard DIN 912) 200 [148] M Pressure measurement M14 x 1,5 (DIN 852) 45 [] F Drain M16 x 1.5 (DIN 852) 0 [0] 60 [44] 40 12/04/1

POCLAIN HYDRAULICS Hydraulic components Model code V P L B 1 5 0 0 0 0 1 0 4 0 0 0 0 High pressure relief valve 1.5 [21.7] 002 10 [145] 010 15 [217] 015 External drain Without 0 With E Other hydraulic components Hydraulic blocks 12/04/1 41

Hydraulic components POCLAIN HYDRAULICS ADJUSTABLE PRESSURE LIMITER VPB25 Function: Create back pressure in open loop circuit. Commercial Description BLOC RB25 F5/15 Part number 0014429L Compatibility All types of circuit Hydraulic symbol 1 Caracteristics Mass Flow.5 kg [7.7 lb] 260 L/min [70 GPM] Pressure drop Setting curve max. P bar Setting curve min. P PSI L/min GPM 42 12/04/1

POCLAIN HYDRAULICS Hydraulic components Dimensions Installation Valve mounting position : Indifferent. Chassis mounting : Ref. Quantity Class N.m [lb.ft] ± 10 % (as per standard DIN 912) 1 M10 2 8.8 50 [7] Hydraulic connections: Other hydraulic components Hydraulic blocks Port Function Connection Max pressure 01 Input 42 gaz cyl. [1'' 1/4 BSPP] 1 Output 15 max. [max. 220] N.m [lb.ft] ± 10 % (as per standard DIN 912) 62 [466] 1* Output 21 gaz cyl. [1/2'' BSPP] 160 [118] F Drain 1 gaz cyl. [1/2'' BSPP] 0 [0] 0 [22] 12/04/1 4

Hydraulic components POCLAIN HYDRAULICS FREE-WHEELING VALVE H25 Function: On motor, connects the ports A and R (or L and R on motor 1C) to tank and allows the pistons to return in cylinder-blocks and the motor to turn in free-wheeling. Protect the motor from pressure spikes in the casing. Commercial Description Part number Compatibility Hydraulic symbol BLOC DE DECRABOTAGE H25 BLOC DE DECRABOTAGE H25 U 00244681A (metric connections) 0064608T (UNF connections) All types of circuit Caracteristics Mass Flow Pilot pressure 22 kg [48.5 lb] 260 L/min [70 GPM] 7 to 10 bar [100 to 145 PSI] 44 12/04/1

POCLAIN HYDRAULICS Hydraulic components Dimensions Installation Valve mounting position : Chassis mounting : Indifferent. Ref. Quantity Class Hydraulic connections: N.m [lb.ft] ± 10 % (as per standard DIN 912) M10 4 8.8 50 [7] Port Function Connection Max pressure PAV Input forward PAR Input reverse forward DN 25 PN 400 AV Output forward (ISO 9 974-1) AR Output reverse forward G F 1 Pilot Drain M27 x 2 (ISO 9 974-1) M16 x 1.5 (ISO 9 974-1) 1 1/16-12 UNF (ISO 11 926) 9/16-18 UNF (ISO 11 926) N.m [lb.ft] ± 10 % (as per standard DIN 912) 450 [6 526] 55 [41] 100 [1 450] 200 [148] 0 [0] 60 [44] Other hydraulic components Hydraulic blocks 12/04/1 45

Hydraulic components POCLAIN HYDRAULICS FREE-WHEELING VALVE H15 Function: On motor, connects the ports A and R (or L and R on motor 1C) to tank and allows the pistons to return in cylinder-blocks and the motor to turn in free-wheeling. Protect the motor from pressure spikes in the casing. Commercial Description Part number Compatibility Hydraulic symbol BLOC DECRABOTAGE H15 00244688H All types of circuit PAV PAR F AV G AR Caracteristics Mass Flow Control pressure 15 kg [.1 lb] 65 L/min [17 GPM] 6 to 9 bar [90 to 10 PSI] Pessure drop P bar P PSI L/min GPM 46 12/04/1

POCLAIN HYDRAULICS Hydraulic components Dimensions Installation Valve mounting position : Indifferent. Chassis mounting : Ref. Quantity Class N.m [lb.ft] ± 10 % (as per standard DIN 912) 1 M12 4 8.8 86 [6] Hydraulic connections: Other hydraulic components Hydraulic blocks Port Function Connection Max. pressure PAV Input forward PAR Input reverse forward 450 [6 526] AV Output forward M27 x 2 AR Output reverse forward G Pilot 100 [1 450] F Drain 0 [0] N.m [lb.ft] ± 10 % (as per standard DIN 912) 200 [148] 12/04/1 47

Hydraulic components POCLAIN HYDRAULICS DIRECTIONAL CONTROL VALVE VD 2V 2H20/H25 Function: Two position flow directional control valve, opens or closes a circuit. Valve VD 2V 2H20 Valve VD 2V 2H25 Commercial Description VD 2V 2H20 VD 2V 2H25 Part number 009468U (VD 2V 2H20) 009467T (VD 2V 2H25) Compatibility All types of circuit Hydraulic symbol Caracteristics Mass 8 kg [18 lb] Commercial Description Pressure Flow L/min [GPM] VD 2V 2H20 92 to 170 [25 to 45] 450 [6 526] VD 2V 2H25 170 to 00 [45 to 80] Pressure drop (1 2 or 1 ) VD 2V 2H20 VD 2V 2H25 P bar P PSI L/min GPM 48 11/04/1

POCLAIN HYDRAULICS Hydraulic components VD 2V 2H 20 Dimensions VD 2V 2H 25 Dimensions Installation Valve mounting position : Chassis mounting : The plug can positionned in Indifferent. Ref. Quantity Class Hydraulic connections: Port 1 Function 1-2- HP circuit N.m [lb.ft] ± 10 % (as per standard DIN 912) M10 4 8.8 50 [7] Max. N.m [lb.ft] ± 10 % Connection pressurebar (as per standard DIN 912) H20 H25 [PSI] H20 H25 DN 19 (NF E 48 055) SAE 6000 PSI /4'' (ISO DP 6162) DN 25 (NF E 48 055) SAE 6000 PSI 1'' (ISO DP 6162) Z Pilot 5 [75.2] + F M16 x 1.5 F Drain [45] 450 [6 526] 55 [41] 60 [44] 60 [44] Other hydraulic components Hydraulic blocks The pressure in F port must be added to the pressure in Z port (control). 11/04/1 49

Hydraulic components POCLAIN HYDRAULICS DIRECTIONAL CONTROL VALVES VD V 2H 20/25 Function: Two position flow directional control valve, allowing to dired a circuit. Valve VD V 2H 20 Valve VD V 2H 25 VD V 2H20 Commercial Description VD V 2H25 Part number 009419R (VD V 2H20) 009420S (VD V 2H25) Compatibility All types of circuit Hydraulic symbol Caracteristics Mass 8 kg [18 lb] Commercial Description Pressure Flow L/min [GPM] 92 to 170 [25 to 45] VD V 2H20 450 [6 526] VD V 2H25 170 to 00 [45 to 80] Pressure drop VD V 2H20 VD V 2H25 P bar P PSI L/min GPM 50 11/04/1

POCLAIN HYDRAULICS Hydraulic components VD V 2H 20 Dimensions VD V 2H 25 Dimensions Installation Valve mounting position : Indifferent. Chassis mounting : Ref. Quantity Class N.m [lb.ft] ± 10 % (as per standard DIN 912) 1 M10 4 8.8 50 [7] Hydraulic connections: Other hydraulic components Hydraulic blocks Port Function 1-2- HP circuit Max. N.m [lb.ft] ± 10 % Connection pressurebar (as per standard DIN 912) H20 H25 [PSI] H20 H25 DN 19 (NF E 48 055) SAE 6000 PSI /4'' (ISO DP 6162) DN 25 (NF E 48 055) SAE 6000 PSI 1'' (ISO DP 6162) Z Pilot 5 [75.2] + F M16 x 1.5 F Drain [45] 450 [6 526] 55 [41] 60 [44] 60 [44] The pressure in F port must be added to the pressure in Z port (control). 11/04/1 51

Hydraulic components POCLAIN HYDRAULICS TWO POSITION CONTROL VALVE VD 1V 2B5L Function: Two position flow directional control valve. Control of motor displacement and brake release. Commercial Description Part number Compatibility Hydraulic symbol VD1-B05-20-M1L0-000-0000 0017457D All types of circuit Caracteristics Mass Flow Max. pressure 1.5 kg [. lb].5 to 10 L/min [1 to 2.5 GPM] 50 bar [725 PSI] Pressure drop (P A1) P bar P PSI L/min GPM 52 11/04/1

POCLAIN HYDRAULICS Hydraulic components Dimensions Installation Valve mounting position : Chassis mounting : Indifferent. Ref. Quantity Class 1 Hydraulic connections: N.m [lb.ft] ± 10 % (as per standard DIN 912) M6 2 8.8 10 [7.4] Port Function Connection Max. pressure P A F Input Output Drain 1 gaz cyl. [1/4'' BSPP] N.m [lb.ft] ± 10 % (as per standard DIN 912) 50 [752] 0 [22] For better maneuverability of the levers, ensure a maximum pressure of 10 bar [145 PSI] in F. Other hydraulic components Hydraulic blocks 11/04/1 5

Hydraulic components POCLAIN HYDRAULICS TWO POSITION CONTROL VALVE VD 2V 2B5 L Function: Two position flow directional control valve. Control of motor displacement and brake release. Commercial Description Part number Compatibility Hydraulic symbol VD2-B05-20-M1L0-000-0000 0017458E All types of circuit Caracteristics Mass Flow Max. pressure 2.2 kg [4.8 lb].5 to 10 L/min [1 to 2.5 GPM] 50 bar [725 PSI] Pressure drop (P A2) P bar P PSI L/min GPM 54 11/04/1

POCLAIN HYDRAULICS Hydraulic components For pressure losses P to A1, see the table of pressure drop of valve VD 1V 2B5L. Dimensions Installation Valve mounting position : Chassis mounting : Indifferent. Ref. Quantity Class 1 Hydraulic connections: N.m [lb.ft] ± 10 % (as per standard DIN 912) M6 2 8.8 10 [7.4] Port Function Connection Max. pressure P A1-A2 F Input Output Drain 1 gaz cyl. [1/4'' BSPP] N.m [lb.ft] ± 10 % (as per standard DIN 912) 50 [752] 0 [22] For better maneuverability of the levers, ensure a maximum pressure of 10 bar [145 PSI] in F. Other hydraulic components Hydraulic blocks 11/04/1 55

Hydraulic components POCLAIN HYDRAULICS TWO POSITION CONTROL VALVE VD V 2B5L Function: Two position flow directional control valve. Control of motor displacement and brake release. Commercial Description Part number Compatibility Hydraulic symbol selecteur V 2B5L 0017459F All types of circuit Caracteristics Mass Flow Max. pressure kg [7 lb].5 to 10 L/min [1 to 2.5 GPM] 50 bar [725 PSI] Pressure drop (P A) P bar P PSI L/min GPM 56 11/04/1

POCLAIN HYDRAULICS Hydraulic components For pressure losses P to A1, see the table of pressure drop of valve VD 1V 2B5L. For that P to A2, see the table of valve VD 2V 2B5L. Dimensions Installation Valve mounting position : Chassis mounting : Indifferent. Ref. Quantity Class 1 Hydraulic connections: N.m [lb.ft] ± 10 % (as per standard DIN 912) M6 2 8.8 10 [7.4] Port Function Connection Max. pressure P A1-A2-A F Input Output Drain Ø 1 gaz cyl. [1/4'' BSPP] N.m [lb.ft] ± 10 % (as per standard DIN 912) 50 [752] 0 [22] For better maneuverability of the levers, ensure a maximum pressure of 10 bar [145 PSI] in F. Other hydraulic components Hydraulic blocks 11/04/1 57

Hydraulic components POCLAIN HYDRAULICS DIRECTIONAL CONTROL VALVES VDP Function: Directional control valve on TwinLock circuit and mechanical or hydraulic proportional control. Commercial Description VDP H10 2 M1G0 100 0000 VDP H10 2 M1G0 110 0000 VDP H10 1 M1G0 110 0000 VDP H10 1 M1G0 210 0000 Part number 0046446Q (VDP H10 2 M1G0 100 0000) 0046487K (VDP H10 2 M1G0 110 0000) 0046482E (VDP H10 1 M1G0 110 0000) 005041M (VDP H10 1 M1G0 210 0000) Compatibility TwinLock Circuit Hydraulic symbol 0046446Q 0046487K 0046482E 005041M Caracteristics 0046446Q 0046487K 0046482E 005041M Max. pressure Flow L/min [GPM] 450 [6 526] 26 to 50 [7 to 1] Mass kg [lb] 2.65 [5.8]. [7.] 58 12/04/1

POCLAIN HYDRAULICS Hydraulic components DimensionsVDP H10 2 M1G0 100 0000 Dimensions VDP H10 2 M1G0 110 0000 VDP H10 1 M1G0 110 0000 Dimensions VDP H10 1 M1G0 210 0000 Other hydraulic components Hydraulic blocks 12/04/1 59

Hydraulic components POCLAIN HYDRAULICS The operation of the cam on the roller must be limited to 0 to limit the parasite forces. Mechanical control Hydraulic control Beginning of opening N [lbf] End of opening N [lbf] Max. stroke mm [in] 0046446Q 25 [5.62] 55 [12.6] 10 [0.9] 0046487K 0046482E 005041M 49 [11.02] 170 [8.22] 16 [0.6] Beginning of opening End of opening 0046446Q 5 [72.5] 11 [160] 0046487K 0046482E 4 [58] 15 [218] 005041M Max. pressure 50 [725] 0046446Q: 0046487K 0046482E 004641M mm² in² mm² in² mm in bar mm in bar PSI PSI 60 12/04/1

POCLAIN HYDRAULICS Hydraulic components Installation Valve mounting position: Chassis mounting: Indifferent. Ref. Quantity Class N.m [lb.ft] ± 10 % (as per standard DIN 912) 1 M8 2 8.8 25 [18] Hydraulic connections: Port Function Connection Max. pressure N.m [lb.ft] ± 10 % (as per standard DIN 912) P-A-B HP circuit M18 x 1.5 450 [6 526] 70 [52] X Pilot 50 [752] M14 x 1.5 45 [] L Drain [45] Other hydraulic components Hydraulic blocks 12/04/1 61

OTHER COMPONENTS Hydraulic components POCLAIN HYDRAULICS HYDRO-PNEUMATIC BRAKING CIRCUIT ACCUMULATOR Function: Dedicated power reserve for dynamic brake safety circuits. Conforms to German standard STVZO- 41. The accumulated volume must provide for 9 braking operations. Commercial Description Part number Technology Compatibility Hydraulic symbol ACCU. 0,5 L PG 65 B 00114020F Membrane Accumulator All types of transmission Features Nominal volume Max permissible pressure Inflation pressure Mass Operating temperature range Inflation gas Nitrile quality Oil used 0.5 L [0.5 cu.in] 160 bar [2 20 PSI] 65 bar [942 PSI] (Please contact us for other possible pressures) 2 kg [4.41 lb] -10 C to 80 C [14 F to 176 F] Nitrogen NBR Mineral oil (group 2 fluid) Definitions of volume, inflation pressure, and number of accumulators must be submitted for approval by Poclain Hydraulics application engineers. 62 11/04/1

POCLAIN HYDRAULICS Hydraulic components Dimensions Installation Position mounting Hydraulic connections: Indifferent. Position the accumulator as close as possible to the user equipment. There must be 200 mm of space around the inflation valve to enable access to the accumulator for inflation checking equipment; this checking equipment to have a draining system fitted. A collar needs to be fitted around the accumulator body. This collar must be able to prevent the accumulator from moving in the event of a broken connection. Preferably with rigid tubing: Thread depth Max. pressure BSPP Standard connection mm [in] N.m [lb.ft] ± 10 % Ø 21 [G 1/2 ] 14 [0.55] 160 [220] 160 [118] Always drain accumulators before disconnecting any tubing. Adjust the distribution and purge valves, referring to the hydraulic diagram for the whole installation. Other hydraulic components Hydraulic blocks 11/04/1 6

Hydraulic components POCLAIN HYDRAULICS HYDRO-PNEUMATIC BRAKING CIRCUIT ACCUMULATOR Function: Dedicated power reserve for dynamic brake safety circuits. Conforms to German standard STVZO- 41. The accumulated volume must provide for 9 braking operations. Commercial Description Part number Technology Compatibility ACCU.0,5L PG65B-P.MAXI=210 00244028H Membrane Accumulator All types of transmission Hydraulic symbol Features Nominal volume Max permissible pressure Inflation pressure Mass Operating temperature range Inflation gas Nitrile quality Oil used 0.5 L [0.5 cu.in] 210 bar [ 045 PSI] 65 bar [942 PSI] (Please contact us for other possible pressures).6 kg [7.94 lb] -20 C to 80 C [-4 F to 176 F] Nitrogen NBR Mineral oil (group 2 fluid) Definitions of volume, inflation pressure, and number of accumulators must be submitted for approval by Poclain Hydraulics application engineers. 64 11/04/1

POCLAIN HYDRAULICS Hydraulic components Dimensions Installation Position mounting Hydraulic connections: Indifferent. Position the accumulator as close as possible to the user equipment. There must be 200 mm of space around the inflation valve to enable access to the accumulator for inflation checking equipment; this checking equipment to have a draining system fitted. A collar needs to be fitted around the accumulator body. This collar must be able to prevent the accumulator from moving in the event of a broken connection. Preferably with rigid tubing: Thread depth Max. pressure BSPP Standard connection mm [in] N.m [lb.ft] ± 10 % M 18 x 1.5 14 [0.55] 210 [ 045] 70 [52] Always drain accumulators before disconnecting any tubing. Adjust the distribution and purge valves, referring to the hydraulic diagram for the whole installation. Other hydraulic components Hydraulic blocks 11/04/1 65

Hydraulic components POCLAIN HYDRAULICS HYDRO-PNEUMATIC RETURN AND BOOSTER CIRCUIT ACCUMULATOR (1.L) Function: Pressure limiting in return circuit. Commercial Description ACCU 1, L 0,5 BAR EQ Part number 0.5 bar [7.25 PSI] : 00244029J (Type B) Function Part number 8 bar [116 PSI] : 0052771L (Type A) 12 bar [174 PSI] : 0052772M (Type A) 20 bar [290 PSI] : 005277N (Type A) 0 bar [45 PSI] : 002440240K (Type B) Compatibility All types of transmission Hydraulic symbol Features Type A Type B Nominal volume 1. L [79. cu.in] 1. L [79. cu.in] Max permissible pressure 50 bar [725 PSI] 210 bar [045 PSI] Inflation pressure According to model According to model Mass 1.7 kg [.75 lb].6 kg [7.94 lb] Operating temperature range -10 C to 80 C [14 F to 176 F] -20 C to 80 C [-4 F to 176 F] Inflation gas Nitrogen - Oil used Mineral oil (group 2 fluid) Definitions of volume, inflation pressure, and number of accumulators must be submitted for approval by Poclain Hydraulics application engineers. 66 12/04/1

POCLAIN HYDRAULICS Hydraulic components Dimensions Type A Type B Installation Position mounting Use (Type A) Available volume Indifferent. Position the accumulator as close as possible to the user equipment. There must be 200 mm of space around the inflation valve to enable access to the accumulator for inflation checking equipment; this checking equipment to have a draining system fitted. A collar needs to be fitted around the accumulator body. This collar must be able to prevent the accumulator from moving in the event of a broken connection. Connection N.m [lb.ft] ± 10 % M22 x 1.5 100 [74] L These accumulators can be fitted with a male-female reducer M22x1.5 -G Ø27 [/4"] (part number : 000671G), and an O-ring 262002507NBR-80 (part number : 00000460J). Cu.in bar Other hydraulic components Hydraulic blocks Service pressure PSI Maintenance Accumulators greater than 1l must be regularly inspected. Refer to European Directive 97/2/CE. Precautions in use Always drain accumulators before disconnecting any tubing. Adjust the distribution and purge valves, referring to the hydraulic diagram for the whole installation. 12/04/1 67

Thirteen subsidiaries and a worldwide network of more than 150 distributors and partners 12/04/1 A01886A A01887B Poclain Hydraulics reserves the right to make any modifications it deems necessary to the products described in this document without prior notification.the information contained in this document must be confirmed by Poclain Hydraulics before any order is submitted. Illustrations are not binding. The Poclain Hydraulics brand is the property of Poclain Hydraulics S.A. More information on