Fisher D4 Control Valve Assembly

Similar documents
Design D4 Control Valve

Fisher D4 Control Valve Assembly

Design D and DA Control Valves

Type D2 FloPro Control Valve

Fisher CV500 Rotary Control Valve

Fisher D and DA Control Valves

Fisher V500 Rotary Control Valve

Fisher CV500 Rotary Globe Control Valve

Fisher V250 Rotary Control Valve

Fisherr easy -et Cryogenic Sliding -Stem Control Valves

Fisher CAV4 Control Valve

Fisher eplug complete Rotary Control Valve and Actuator Package

Fisher 8590 High-Performance Butterfly Valve

Fisher EU and EW Valves NPS 12 through 24 x 20

Fisher V500 Rotary Globe Control Valve

Baumann Corrosion Resistant Control Valve

Fisher V260 Ball Control Valve

Design V250 Rotary Control Valve

Fisher FB Control Valve

Fisher 461 Increased Outlet Angle Sweep-Flo Valve

Features. Product Bulletin 51.6:8590 August Valve D104017X012

Fisher CL600 Control-Disk Valve

Fisher A31D Double-Flange High-Performance Butterfly Valve

Fisher SS-138B Continuous Catalytic Regeneration Valve

Fisher A31D Double-Flange High-Performance Butterfly Valve

Fisher CCV-N Fuel Gas Control Valve

Fisher 8510 and 8510B Eccentric Disc Control Valves (EMA)

Model DF100 Control Valve

Fisher SS-252B Continuous Catalytic Regeneration Valve

Fisher CAV4 Control Valve

Fisher EZ-Overtravel (EZ-OVT) Valve Trim

Model DF269 Control Valves

Fisher CAV4 Control Valve

Fisher 8580 Rotary Valve

Design V260 Ball Control Valve

Fisher D2T FloPro Control Valve

Fisher D4 Control Valve Assembly

Fisher 8580 Rotary Valve

Fisher POSI-SEAL A31A Cryogenic High Performance Butterfly Valve

Fisher Z500 Severe Service Ball Valves

Fisher YD and YS Control Valves

Fisher Control-Disk Rotary Valve

Fisher Large ED/EWD and ET/EWT Valves NPS 12 through 30

Fisher 8532 High-Performance Butterfly Valve

Fisher 8532 High-Performance Butterfly Valve

DF100 Control Valve. Features. Model. Patents Pending

Fisher Large ED/EWD and ET/EWT Valves NPS 12 through 30

Fisher 9500 Butterfly Control Valve

Fisher RSS Lined Globe Valve

Fisher 377 Trip Valve

Fisherr D4 Control Valve Assembly

Fisher FIELDVUE DVC6000 Digital Valve Controller Dimensions

Baumann 24000S Stainless Steel Control Valve

Baumann 24000CVF Carbon & 24000SVF Stainless Steel Flanged Control Valves

Fisher Multi-Port Flow Selector Valve

Fisher Control-Disk Valve NPS 14-24

Vee-Ball Design V150, V200 and V300 Rotary Control Valves

Fisher V150S Slurry Vee-Ball Control Valve

Fisher 2100 Pneumatic and 2100E Electric Liquid Level Switches

Fisher FIELDVUE DVC6200 Digital Valve Controller / Magnet Assembly Dimensions

Fisher Vee-Ball V150, V200 and V300 Rotary Control Valves

Fisher L3 Pneumatic Level Controller

Model DF233 Control Valves

Type 8560 Eccentric Disk Butterfly Control Valve

L3 Pneumatic Level Controller

Fisher 3024C Diaphragm Actuator

Model DF233 Control Valves

Fisher 657 and 667 Diaphragm Actuators

Baumann Flexsleev Sanitary Control Valve

Fisher WhisperFlo Aerodynamic Noise Attenuation Trim

Fisherr 2052 Diaphragm Rotary Actuator

Fisher RSS Lined Globe Valve

Fisher VBL Volume Booster

Fisher DFA Variable Geometry Desuperheater

Baumann NV Electric Actuator with Control Valves

Fisher A31A Cryogenic High Performance Butterfly Valve

Fisher HP Series Control Valves

Fisher 546 Electro Pneumatic Transducer

Fisher Vee-Ball V150, V200, and V300 Rotary Control Valves

Fisher 2052 Diaphragm Rotary Actuator

Fisher ES and EAS Sliding-Stem Control Valves

WARNING. Mounting Instructions D103998X012 June DVC6200/DVC2000 Digital Valve Controller Linear Actuator Side Mount

Baumann Sanitary Angle Control Valve

Fisher 377 Trip Valve

Fisher Vee-Ball V150, V200, and V300 Rotary Control Valves

Fisher HP Series Control Valves

Fisher A11 High-Performance Butterfly Valve

Fisher 480 Series Yokeless Piston Actuators

Baumann 24000CVF Carbon & 24000SVF Stainless Steel Flanged Valve Instructions

Baumann Sanitary Diaphragm Angle & In-Line Control Valve Instructions

Fisher HP Series Control Valves

Design V150S Slurry Vee-Ball Control Valve

Model 370/371 Control Valves

Fisherr 1051 and 1052 Diaphragm Rotary Actuators

Fisher TBX Steam Conditioning Valve

Fisher FIELDVUE DVC6200 Series Hazardous Area Approval Nameplates

Fisher 1077 Manual Handwheel Rotary Actuator

Fisher Vee-Ball V150, V200, and V300 Rotary Control Valves

CML Electric Actuator for Baumann Series

Model 2000 Control Valves Technical Sales Bulletin

Transcription:

Product Bulletin D103039X012 Fisher D4 Control Valve Assembly D4 Valve The Fisher D4 control valve is a compact, rugged globe valve designed primarily for high-pressure throttling applications. This valve is ideal for use on pressure and flow control applications within the oil and gas production industry. The D4 is an excellent control valve for high-pressure separators, scrubbers, and other processing equipment. These valves are especially useful for either throttling or on/off control of liquids or gases which are gritty, sticky, or which have a tendency to build up on internal valve parts. If the control valve requires maintenance, the trim and packing can be maintained by removing the deep-bore hammer nut and lifting the actuator/bonnet assembly off the valve without disassembling the actuator. Features Safer Bonnet / Valve Body Connection Unique design provides additional protection if disassembly of bonnet/valve body connection is inadvertently started while there is still pressure in the valve body. Pins mounted in the valve bonnet help ensure the bonnet disengages from the valve body as the hammer nut is removed, while the threads are still engaged. Heavy-Duty Guiding Massive guiding (figures 2 and 3) positively aligns the valve plug in the seat ring for reliable service. The screwed-in seat ring completely encloses the seat ring gasket. Live-loaded Packing System The packing system provides an improved stem seal to help prevent the loss of valuable or hazardous process fluids or gases. It features Fisher ENVIRO-SEAL packing technology to provide reduced packing maintenance. W8531/IL Figure 1. Fisher D4 Control Valve NACE Constructions NACE compatible trim is available with the D4 control valve. These constructions meet the metallurgical requirements of NACE MR0175 / ISO 15156. Low Temperature Materials Valve construction materials allow use in applications as low as C ( 50 F). Quick-Change Valve Plug Removable groove pin allows quick, easy valve plug replacement. www.fisher.com

D4 Valve Product Bulletin Features (continued) Severe Service Capability with Tungsten Carbide Trim D4 valves are available with tungsten carbide trim for erosive service. This trim is designed specifically for severe service applications in the oil and gas industry. Durable tungsten carbide trim may benefit your application by wearing better and lasting longer. Easy Installation Compact design allows installation where space is a premium. Screwed valve bodies feature compact face-to-face dimensions while flanged valve bodies conform to ISA-75 standards for maximum versatility. Easy Maintenance Hammer nut bonnet/body joint allows repair or maintenance with a minimum of tools, without removing the valve body from the piping system. Seat ring can be removed with the same service tools used with a Fisher D valve. Integral Bonnet Flange Bonnet has an integral flange that accepts hammer nut force when making the bonnet-to-body connection. There are no snap rings subject to possible failure in sour service or in atmospheric corrosion. Standard Trim for Throttling or On-Off Service Micro-Form trim is standard for throttling or on-off service at no extra cost. Application Flexibility Choices of port diameters up to 31.8 mm (1.25 inches), end connections, and trim materials suit these valves to many applications, including sour service. Installation D4 control valves may be installed in any position, but normally the actuator is vertical and above the valve. Install the control valve so the flow direction arrow on the side of the valve body indicates the direction of the process flow. Dimensions are shown in tables 9 and 10 and figures 4 and 5. Ordering Information When ordering, specify: Application Information 1. Type of application a. Throttling or on-off b. Reducing or relief (back pressure) 2. Controlled fluid a. Type (include chemical analysis, if available) b. Temperature (normal and maximum anticipated) c. Specific gravity 3. Range of flowing inlet pressures 4. Pressure drops a. Range of flowing pressure drops b. Maximum drop at shutoff 5. Flow rates a. Minimum controlled flow b. Normal flow c. Maximum flow 6. Input signal range to actuator Control Valve Assembly Information Refer to the Specifications and review the information under each specification. 2

Product Bulletin D4 Valve GE02329-B Figure 2. Fisher D4 Control Valve with Size 40 Actuator and NPS 2 Flanged Valve Body (Spring-To-Close Configuration) 3

D4 Valve Product Bulletin GE02330-D Figure 3. Fisher D4 Control Valve with Size 40 Actuator and NPS 2 Flanged Valve Body (Spring-To-Open Configuration) 4

Product Bulletin D4 Valve Table 1. Valve Sizes and Connection Styles VALVE SIZE, NPS PORT DIAMETER, (INCHES) 0.25, 0.375, 1 0.5, 0.75 0.25, 0.375, 2 0.5, 0.75, 1, 1.25 X = Available construction. SCREWED RAISED FACE (RF) FLANGED psi CL150 CL300 CL600 CL900 and 1500 RING TYPE JOINT (RTJ) FLANGED CL900 and CL600 1500 X X X X X X X X X X X X X X Table 2. Fisher D4 Control Valves Approximate Weights, Kg (Pounds) Valve Body Size, NPS 1 2 Screwed 32 (71) 39 (87) CL150 34 (74) 39 (86) CL300 and 600 37 (81) 48 (106) CL900 and 1500 50 (110) 66 (1) Table 3. Typical Combinations of Metal Trim Parts DESIGNATION VALVE PLUG SEAT RING Standard S41600 hardened to 38 HRC minimum S17400 Sour S17400 (NACE MR0175/ISO 15156) S17400 (NACE MR0175/ISO 15156) Tungsten Carbide Tungsten carbide / S17400 (NACE MR0175/ISO 15156) Tungsten carbide / S17400 (NACE MR0175/ISO 15156) Table 4. Fisher D4 Environmental Limits for NACE MR0175/ISO 15156 with Sour Trim MAXIMUM TEMPERATURE MAXIMUM H 2 S PARTIAL PRESSURE COMPATIBLE WITH C F MPa psia ELEMENTAL SULFUR? 204 400 1.4 200 No 199 390 2.3 330 No 191 375 2.5 360 No 149 300 2.8 400 No 135 275 No Limit Yes 5

D4 Valve Product Bulletin Table 5. Maximum Shutoff Pressure Drops (1) for Fisher D4 Control Valves (Spring-to-Close) When Used with Typical Control Instrumentation (2) INPUT SIGNAL TO ACTUATOR 0 to 1.2 Bar (0 to 18 Psig) 0 to 1.4 Bar (0 to 20 Psig) 0 to 2.0 Bar (0 to 30 Psig) 0 to 2.3 Bar (0 to 33 Psig) SPRING Light Rate Heavy Rate INITIAL SPRING SETTING PORT DIAMETER 0.77 Bar (11.2 Psig) 0.77 Bar (11.2 Psig) 0.85 Bar (12.4 Psig) 1.05 Bar (15.3 Psig) Maximum Pressure Drop 0 to 2.4 Bar (0 to 35 Psig) 1.18 Bar (17.1 Psig) 0 to 3.4 Bar (0 to 50 Psig) 1.18 Bar (17.1 Psig) mm Inches Bar Psi Bar Psi Bar Psi Bar Psi Bar Psi Bar Psi 6.4 9.5 12.7 19.1 25.4 31.8 0.25 0.375 0.5 0.75 1 1.25 (3) (3) 191 80 42 25 (3) (3) 2765 1160 610 365 (3) (3) 191 80 42 25 (3) (3) 2765 1160 610 365 219 92 49 30 3180 1340 715 430 288 123 67 41 4180 1785 965 590 1. The pressure or temperature limits in the referenced tables and any applicable ASME code limitations should not be exceeded. 2. For example, use the column marked 0-1.4 bar (0-20 psig) for a 0.21-1.0 bar (3-15 psig) pneumatic controller with 1.4 bar (20 psig) supply pressure. 3. For applications with downstream pressure in excess of 196 bar (2845 psig), use 196 bar (2845 psig) for Maximum Shutoff Pressure. 143 78 48 2080 1130 0 143 78 48 2080 1130 0 Table 6. Maximum Shutoff Pressure Drops (1) for Fisher D4 Control Valves (Spring-to-Close) When Used with Instrumentation with Restricted Output Range (2) INPUT SIGNAL TO ACTUATOR 0.4 to 2.0 Bar (6 to 30 Psig) 0.14 to 2.3 Bar (2 to 33 Psig) SPRING Heavy Rate Heavy Rate INITIAL SPRING SETTING 0.97 Bar (14.0 Psig) 1.17 Bar (17.0 Psig) PORT DIAMETER Maximum Pressure Drop mm Inches Bar Psi Bar Psi 6.4 9.5 12.7 19.1 25.4 31.8 0.25 0.375 0.5 0.75 1 1.25 (3) 210 (3) 113 45 23 13 (3) 3045 (3) 1635 655 330 185 1. The pressure or temperature limits in the referenced tables and any applicable ASME code limitations should not be exceeded. 2. For example, an Electro-Pneumatic Transducer calibrated for 0.4-2.0 bar (6-30 psig) output pressure. 3. For applications with downstream pressure in excess of 118 bar (1715 psig), use 118 bar (1715 psig) for Maximum Shutoff Pressure. 282 120 65 39 4095 1750 945 580 6

Product Bulletin D4 Valve Table 7. Maximum Shutoff Pressure Drops (1) for Fisher D4 Control Valves (Spring-to-Open) When Used with Typical Control Instrumentation (2) INPUT SIGNAL TO ACTUATOR 0 to 1.2 Bar (0 to 18 Psig) 0 to 1.4 Bar (0 to 20 Psig) 0 to 2.0 Bar (0 to 30 Psig) 0 to 2.3 Bar (0 to 33 Psig) SPRING Light Rate Heavy Rate INITIAL SPRING SETTING PORT DIAMETER 0.23 Bar (3.4 Psig) 0.23 Bar (3.4 Psig) 0.28 Bar (4.0 Psig) 0.28 Bar (4.0 Psig) 0 to 2.4 Bar (0 to 35 Psig) 0.28 Bar (4.0 Psig) 0 to 3.4 Bar (0 to 50 Psig) 0.28 Bar (4.0 Psig) Maximum Pressure Drop mm Inches Bar Psi Bar Psi Bar Psi Bar Psi Bar Psi Bar Psi 6.4 9.5 12.7 19.1 25.4 31.8 0.25 0.375 0.5 0.75 1 1.25 (3) (3) 187 78 41 24 (3) (3) 2715 1135 600 355 (3) (3) 233 99 53 32 (3) (3) 3380 1430 765 5 147 80 49 2130 1160 715 178 97 60 2575 1410 875 1. The pressure or temperature limits in the referenced tables and any applicable ASME code limitations should not be exceeded. 2. For example, use the column marked 0-1.4 bar (0-20 psig) for a 0.21-1.0 bar (3-15 psig) pneumatic controller with 1.4 bar (20 psig) supply pressure. 3. For applications with downstream pressure in excess of 190 bar (2760 psig), use 190 bar (2760 psig) for Maximum Shutoff Pressure. 198 109 68 2875 1575 985 195 123 2830 1785 Table 8. Maximum Shutoff Pressure Drops (1) for Fisher D4 Control Valves (Spring-to-Open) When Used with Instrumentation with Restricted Output Range (2) INPUT SIGNAL TO ACTUATOR 0.4 to 2.0 Bar (6 to 30 Psig) 0.14 to 2.3 Bar (2 to 33 Psig) SPRING Heavy Rate Heavy Rate INITIAL SPRING SETTING 0.69 Bar (10.0 Psig) 0.42 Bar (6.1 Psig) PORT DIAMETER Maximum Pressure Drop mm Inches Bar Psi Bar Psi 6.4 9.5 12.7 19.1 25.4 31.8 0.25 0.375 0.5 0.75 1 1.25 (3) (3) 196 82 43 26 (3) (3) 2845 1195 630 380 1. The pressure or temperature limits in the referenced tables and any applicable ASME code limitations should not be exceeded. 2. For example, an Electro-Pneumatic Transducer calibrated for 0.4-2.0 bar (6-30 psig) output pressure. 3. For applications with downstream pressure in excess of 202 bar (2925 psig), use 202 bar (2925 psig) for Maximum Shutoff Pressure. 156 85 52 2265 1235 765 Table 9. Dimensions (1) END NPS 1 VALVE BODY NPS 2 VALVE BODY CONNECTION A D G A D G STYLE mm Inches mm Inches mm Inches mm Inches mm Inches mm Inches Screwed CL150 RF Flg CL300 RF Flg CL600 RF Flg CL600 RTJ Flg CL900/1500 RF Flg CL900/1500 RTJ Flg 1. Also see figures 4 and 5. 155 184 197 210 210 273 273 6.12 7.25 7.75 8.25 8.25 10.75 10.75 230 254 267 286 289 340 343 9.00 10.00 10.50 11.25 11.38 13.38 13.50 Table 10. Dimensions (1) FAIL ACTION C E F mm Inches mm Inches mm Inches Fail Down, Spring-To-Close 333 13.12 312 12.30 241 9.47 Fail Up, Spring-To-Open 333 13.12 324 12.74 - - - - - - 1. Also see figures 4 and 5. 7

D4 Valve Product Bulletin C F E MAX 1/4-18 NPT CONTROL D G A/2 GE02329-B A Figure 4. Fisher D4 Valve Dimensions, Spring-To-Close (also see tables 9 and 10) 8

Product Bulletin D4 Valve C E D G A/2 GE02330-D A Figure 5. Fisher D4 Valve Dimensions, Spring-To-Open (also see tables 9 and 10) 9

D4 Valve Product Bulletin Coefficients Table 11. Fisher D4, Micro-Form Valve Plugs Micro-Form - Flow Up Valve Size, NPS 1 2 1. At 100% travel. Equal Percentage Characteristic Port Total Flow Valve Opening Percent of Total Travel Diameter Travel Coefficient 5 10 20 30 40 50 60 80 90 mm Inches mm Inches 100 6.4 0.25 19 0.75 9.5 0.375 19 0.75 12.7 0.5 19 0.75 19.1 0.75 19 0.75 6.4 0.25 19 0.75 9.5 0.375 19 0.75 12.7 0.5 19 0.75 19.1 0.75 19 0.75 25.4 1 19 0.75 31.8 1.25 19 0.75 C v 0.0679 0.0858 0.122 0.167 0.231 0.325 0.458 0.6 0.905 1.25 1.76 0.96 K v 0.0587 0.0742 0.106 0.144 0.200 0.281 0.396 0.559 0.783 1.08 1.52 - - - X T 0.5 0.623 0.620 0.631 0.585 0.565 0.578 0.569 0.555 0.588 0.569 - - - C v 0.114 0.132 0.205 0.298 0.426 0.590 0.834 1.21 1.75 2.45 3.53 0.95 K v 0.099 0.114 0.177 0.258 0.368 0.510 0.721 1.05 1.51 2.12 3.05 - - - X T 0.776 0.848 0.656 0.673 0.626 0.608 0.589 0.582 0.575 0.588 0.691 - - - C v 0.185 0.235 0.357 0.523 0.752 1.07 1.50 2.13 3.05 4.30 5.87 0.96 K v 0.160 0.203 0.309 0.452 0.650 0.926 1.30 1.84 2.64 3.72 5.08 - - - X T 0.718 0.674 0.640 0.596 0.575 0.592 0.593 0.568 0.569 0.599 0.755 - - - C v 0.324 0.358 0.571 0.900 1.30 1.91 3.04 5.08 7.75 9.56 11.2 0.94 K v 0.280 0.310 0.494 0.779 1.13 1.65 2.63 4.39 6. 8.27 9.69 - - - X T 0.561 0.684 0.645 0.594 0.605 0.614 0.592 0.594 0.613 0.696 0.783 - - - C v 0.0679 0.0858 0.122 0.167 0.231 0.325 0.458 0.6 0.905 1.25 1.76 0.96 K v 0.0587 0.0742 0.106 0.144 0.200 0.281 0.396 0.559 0.783 1.08 1.52 - - - X T 0.5 0.623 0.620 0.631 0.585 0.565 0.578 0.569 0.555 0.588 0.569 - - - C v 0.114 0.132 0.205 0.298 0.426 0.590 0.834 1.21 1.75 2.45 3.53 0.95 K v 0.099 0.114 0.177 0.258 0.368 0.510 0.721 1.05 1.51 2.12 3.05 - - - X T 0.776 0.848 0.656 0.673 0.626 0.608 0.589 0.582 0.575 0.588 0.691 - - - C v 0.186 0.244 0.359 0.540 0.784 1.09 1.52 2.25 3.20 4.49 6.27 0.95 K v 0.161 0.211 0.311 0.7 0.678 0.943 1.32 1.95 2.77 3.88 5.42 - - - X T 0.814 0.699 0.799 0.685 0.593 0.560 0.573 0.531 0.536 0.547 0.612 - - - C v 0.305 0.367 0.583 0.892 1.31 2.02 3.14 5.18 8.01 10.6 13.4 0.92 K v 0.264 0.317 0.504 0.772 1.13 1.75 2.72 4.48 6.93 9.17 11.6 - - - X T 0.697 0.513 0.477 0.481 0.478 0.447 0.400 0.432 0.5 0.512 0.640 - - - C v 0.734 0.922 1.35 1.79 2.38 3.65 5.50 9.04 13.6 17.3 21.6 0.95 K v 0.635 0.798 1.17 1.55 2.06 3.16 4.76 7.82 11.8 15.0 18.7 - - - X T 0.501 0.684 0.658 0.548 0.648 0.548 0.577 0.525 0.513 0.632 0.745 - - - C v 1.08 1.22 1.65 2.26 3.24 5.14 8.90 15.2 22.6 26.9 33.2 0.94 K v 0.934 1.06 1.43 1.96 2.80 4.45 7. 13.1 19.5 23.3 28.7 - - - X T 0.587 0.686 0.636 0.638 0.649 0.520 0.6 0.687 0.680 0.767 0.761 - - - F L (1) 10

Product Bulletin D4 Valve Specifications Available Configurations Spring-To-Close Spring-To-Open Valve Sizes and End Connection Styles (1) See table 1 Dimensions See tables 9 and 10 and figures 4 and 5. Face-to-face dimensions for flanged valves conform to ISA-75.03 (CL150-600) and ANSI/ISA-75.16 Short (CL900/1500) Maximum Inlet Pressures and Temperatures (1) Flanged connections are consistent with the ASME B16.34 pressure-temperature class, subject to Material Temperature Capabilities for the Valve Body Assembly (see following specification). For NPT end connections, the valve body rating is psig. Maximum Pressure Drops (1) See tables 5, 6, 7, and 8 Input Signal to Actuator See tables 5, 6, 7, and 8 Actuator Maximum Casing Pressure 3.4 bar (50 psig) Shutoff Classification per ANSI/FCI -2 and IEC 60534-4 Class IV Flow Characteristic Equal percentage Flow Direction Flow up only Flow Coefficients See the section titled Coefficients in this bulletin or Fisher Catalog 12 Port Diameters See table 1 Construction Materials Valve Body and Bonnet: ASME SA 352 LCC Valve Plug and Seat: See table 3. Valve Stem: S10 Actuator O-Rings: (HNBR) Hydrogenated Nitrile Bonnet O-Ring: Standard: HNBR Optional: Fluoroelastomer Packing: PTFE/Carbon PTFE Packing Springs: N07718 Packing Retainer: S17400 Actuator Diaphragm: Chloroprene Actuator Spring: Painted steel Seat Ring Gasket: S31600 (316 SST) Spring Cover (Fail Up): PVC Valve Plug Travel 19 mm (0.75 inch) Valve Plug Style Micro-Form valve plug Actuator Diaphragm Effective Area 452 cm 2 (69 inches 2 ) Actuator Pressure Connection Size 1/4 NPT internal Material Temperature Capabilities Actuator Assembly: Fail Down, Spring-to-Close: 40 to 93 C ( 40 to 200 F) Fail Up, Spring-to-Open: 40 to 77 C ( 40 to 1 F) Valve Body Assembly: Standard Bonnet O-Ring: to 149 C ( 50 to 300 F) Optional Bonnet Fluoroelastomer O-Ring: 23 to 204 C ( 10 to 400 F) 1. The pressure or temperature limits in the referenced tables and any applicable ASME code limitations should not be exceeded. 11

D4 Valve Product Bulletin Note Neither Emerson, Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for the selection, use, and maintenance of any product remains with the purchaser and end user. Fisher and ENVIRO SEAL are marks owned by one of the companies in the Emerson Process Management business division of Emerson Electric Co. Emerson Process Management, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Neither Emerson, Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user. Emerson Process Management Marshalltown, Iowa 50158 USA Sorocaba, 18087 Brazil Chatham, Kent ME4 4QZ UK Dubai, United Arab Emirates Singapore 1281 Singapore www.fisher.com Fisher 12 Controls International LLC 2002, 2006; All Rights Reserved