AQUASTAR C6. (Comfort 6000) Next Generation Auto Backwash Valve System. (selectable time-pressure or remote cycle start)

Similar documents
Always on the safe side. Made in Austria/Europe.

To ensure proper installation, digital pictures with contact information to before startup.

XCITE Owner s Manual. Reso-not TM Damping System XCITE 1502C HYDRAULIC POWER SUPPLY

PRESSURE GAGES AND TEST TAPS

Installation and Operations Manual

DIESEL Engine Fire Pump Controllers Features

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

Electric Actuated Ball Valves 3-Piece Stainless Steel, Full Port 1/4 to 3 inch NPT

REVISION HISTORY REVISION HISTORY

3200NT Timer Service Manual

Electric Actuated 3-Way Ball Valves L-Port, PVC Body, Teflon/EPDM Seals 1/2 to 2 inch Pipe

Programmable Logic Controller. Mat Nor Mohamad

Updated: October 2012

Tekleen GB6 & GB7 USERS AUTOMATIC FILTERS, INC. MANUAL

Electric Actuated Ball Valves 150 lb Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe Sizes

Suggested list for the Hydraulic and Pneumatic lab Instruments Mechatronics Engineering Department School of Applied Technical Science

Electric Actuated 3-Way Ball Valves T-Port, Stainless Steel, Full Port 1/4 to 2 inch NPT

Series Electric Actuators

INSTALLATION GUIDE. FCC ID NOTICE

GCU-10. Automatic Engine Control Unit Operators Manual

Horizontal Circuit Switchers

2 WAY REMOTE STARTER & ALARM SYSTEM INSTALLATION GUIDE FCC ID NOTICE

ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual

E Series Electric Actuators

ARCHITECTURAL DOOR HARDWARE POWER SUPPLIES & TRANSFORMER CATALOG

AQT-56SE ELECTRONIC SERIES PROGRAMMING MANUAL CONTROL VALVES

Gate & Door Controller with LCD and Intelligent Technology

AUTO-EC-3-E-PLC Electric Filter Backwash Controller Operation & Maintenance Manual

PARKING LOT CONTROLLER WITH LOGIC & MAIN CONTACTOR

ELECTRICAL SYSTEM RP-7

Arch HTH Water Chemicals Commercial Equipment Trouble Shooting Guide

Optimal Series. Automatic Transfer Switch. Installation and User Manual for the OPT2225 Automatic Transfer Switch. Full Version

SALES PRESENTATION FOR RELAYS, CONTACTORS & MOTOR STARTER TESTING EQUIPMENTS

Transfer switch GTEC open or delayed transition

AquaMatic Series. A100 and A200 Stager Controls

Power Supplies DORMA PS

Electric Actuated Ball Valves 150# Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe

Electropneumatic Timing Relays Series 7000 Industrial

Horizontal Circuit Switchers

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER

Q&A FOR Webinar on Electrical Basics & Boiler Wiring

WIRING / CONNECTION GUIDE (20-PIN) SECONDARY CONNECTOR

PNEUTRAINER-200 Pneumatics - Electro-pneumatics

V200 V200. Control on water, proportional integral. Simplified Master / Slave operation GENERAL DESCRIPTION

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Electric Actuators Maximum in-lbs

U S A INSTALLATION GUIDE EP400 / E8-B

Actuated Valves PRICING

SECTION MOTOR CONTROL

Electric Actuators Maximum in-lbs

Lt.Blue/Black. White. Orange. LED Blue LED Yellow LED Red

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

Transfer switch OTEC open or delayed transition

OPERATING INSTRUCTIONS MCP-MT1

Best Diversified Products, Inc. Product Manual. BestReach Rigid Belt. Models BRB 230 OS BRB 230 SS BRB 460 OS BRB 460 SS

INOVA HIGHTECH Ltd. MEP 002/003 Auto Starter Manual

WARNING. Diode Package The Murphy diode package ( ) is designed to allow the fuel shutoff valve to be used with dual Magneto Ignition systems.

ECO3-601/602 EcoStar III * Chevy Express/GMC Savana Contact Intermotive for additional vehicle applications

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

PATTERSON PUMP COMPANY

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Mount directly to 1.05 jackshafts. AF230 US (p. 02) AF230-S US (p. 20) AF24-S US (p. 18)

Levalarm Gold. Installation, Operation, & Maintenance Instructions R500.E253A 03/16/2016

7000 series. Industrial Electropneumatic Timing Relay AGASTAT. Design Features. On-delay model 7012 (delay on pickup) Design & Construction

AC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave

200C II BRAKE SYSTEM

Electrical: Valve monitoring and control circuits

Electro Pneumatic WorkStation Scientech 2470

B100S - Super Swing. Instruction Manual. Document number: B100S-C Release: V4.0 Date: May 08,2009

Compact Electric Actuated 3-Way Ball Valves T-Port, 316 Stainless Steel, Full Port 1/4 to 3/4 NPT

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Atlas Automotive. Equipment. Electro-Mechanical. Design Features

Super-Safe-Plus Roto-Bin-Dicator

RADIO FREQUENCY SYSTEMS

FSAF24(-S) US, FSAF120(-S) US

PIPING PACKAGES For Chilled and Hot Water Fan Coil Units

INSTRUMENTATION & CONTROL

RESISTIVITY MONITOR/CONTROLLERS

Electro Pneumatic Workbench Scientech 2470

Euclid Full Voltage Magnet Controller

CSI-400 Installation Instructions

REVISED ATM72 Auto Transfer Module

Troubleshooting Guide

Transfer switch OTEC and OTECSE open transition

Design Envelope Booster Systems. Design Envelope Booster Systems. FILE NO: DATE: Feb. 05, 2010 SUPERSEDES: DATE: Jan.

Electric Actuated 3-Way Ball Valves T-Port Diverter, Stainless Steel, Full Port 1/4 to 2 NPT

PNEUTRAINER-400 Pneumatics - Electropneumatics

Electric Actuator Options & Accessories

Commercial Softeners

PROCESS & AUTOMATED VALVES

Flight Systems. Replacement for KASSEC DESCRIPTION

Electric Actuated Butterfly Valves Ductile Iron Wafer Body ANSI/ASME 150 lb 2 to 6 inch Pipe

Electric Actuated Ball Valves 3-piece Stainless Steel, Full Port 1/4 to 3 NPT

In this manual you can find how to connect the valve to a standard electric box from Certikin (point 3) or to a DUAL SPEED electric box (point 4).

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

J1 Plug Pin Identification

MANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES M450

RATE CONTROLLED TORQUE WRENCH TESTER

Transcription:

AQUASTAR C6 (Comfort 6000) Next Generation Auto Backwash Valve System (selectable time-pressure or remote cycle start) SIDE MOUNTED AND TOP MOUNTED VALVES WITH QUICK INSTALL ELECTRIC ACTUATORS FOR PIPE SIZES 1.5" - 3 MAX FLOW RATES UP TO 340 USGPM MAX PRESSURE 50PSI MULTIPLE TANK SYSTEMS - MASTER/SLAVE TANDEM LOGIC PROVIDED PLC "PROGRAMMABLE LOGIC CONTROL" MODELS AVAILABLE IN ALL SIZES/STYLES (see separate brochure) MADE IN NORTH AMERICA certified acc. to EN ISO 9001:2000

MULTI-VOLTAGE SMT CIRCUITRY TECHNOLOGY allows voltage operation of AC and DC voltage, 12-230 VAC and 12-34 VDC (50-60 Hz) Integrated emergency valve handle allows a 1 minute switch over to manual operation Handle incorporates socket wrench for servicing BACKWASH CYCLE RELEASE can be initiated with the following standard installed devices: A Pressure sensing in system 6-95 psi Installed pressure tube Connected to electronic transmitter board Adjustable with circuit board mounted pressure selector switch Green pressure sensing LED for visual activation confirmation B Remote activation by other controller: An integrated external cycle start option allows other equipment such as controllers, manual switches, relays, etc. to start the backwash cycle. Closing a provided 6 VDC control circuit on the circuit board will initiate cycle start

C Timer controlled C1 Digital time clock for flexible time controlled backwash releases (up to 25 cycles per day, minimum one per week!) Timer has a battery powered back up power supply. C2 Basic switch timer with 3 release settings: daily, weekly, bi-weekly Off 3 Days 7 Days 14 days Digital time clock Dip switch timer D Pushing the test button on the Touch Pad switch face test button with LED light TIMING OF BACKWASH, RINSE, FIREMAN DELAY duration can be easily field adjusted with board mounted analog dial timers Back wash duration: 50 sec to 9 min Rinse duration: 25 sec to 200 sec Fireman delay duration: 20 sec to 25 min Fireman delay (20 sec to 25 min) is typically used to shut heaters down when the Aquastar controller receives the signal to go into back wash mode. The integrated relay signal will shut down the heater (if connected to the Aquastar relay). That delay time will allow the heater pipes to cool off before the system goes into back wash mode. It is also used to switch on/off chemical feed pumps for duration of backwash and rinse action (thru terminals 21-22). EXTERNAL TOUCH PAD FUNCTIONS provided by a water and steam tight membrane touch pad switch panel with LED indicator lights Touch Pad functions: Test Button: will start a back wash cycle upon being switched on ON: will switch control circuits on OFF: will switch control circuits off DRAIN: will make system go into drain position for lowering water levels and/or for vacuuming direct to waste Press Drain and Test simultaneously for 5 seconds will start the actuator to move into Recirculation position which is a filter bypass position. This is typically used for servicing or troubleshooting.

RELIABILITY BY 25 PLUS YEARS field tested circuitry and mechanical components: A Inductive sensors on circuit board precisely sense actuator positions. B Heavy duty drive train motor with steel gear drive and permanently lubricated high strength thermo set gear. Inductive sensor Motor C Permanently self lubricated thermo set main gear with lifting track perfectly centered on stainless steel ball bearings Main gear Lifting track in main gear for roller bearings of lifting cam Lifting cam with three roller bearings and magnetic indicator D Spring cushioned pressure flex compensation. Stainless steel springs compensate for the possible flexing of the valve cover in higher pressure applications and guarantee mechanical stress free operation of the actuator drive unit. Stainless steel springs PUMP INTERLOCK LOGIC The Aquastar controller requires that pump is interlocked at all times through provided relay contacts #13 and #14. An internal mechanical pump limit switch will release the signal for the main pump control circuits upon actuator travel completion. That switch will also interrupt the pump control circuit during actuator travel. Integrated control logic and provided relay contact allow for external 3 way valve or by pass valve controls if the main filter pump cannot be switched off at all. Pump limit switch activated by cam or gear (not shown) VISUAL ACTUATOR POSITION INDICATION for all positions Filter Waste Backwash Recirculate Rinse Drain

AQUASTAR C6 Dimensions Aquastar C 6 1.5" and 2" SM Aquastar C 6 3" SM Aquastar C 6 1.5" TM 1.5" SM 1.5" TM 2" SM 3" SM A 3.92 4.33 6.69 B 3.54 4.49 6.5 C 1.16 1.24 1.5 1.97 D 1.89 1.85 2.36 3.37 E 2.42 2.34 3.19 4.33 F 6.44 6.3 8.27 12.05 G 11.61 11.46 13.35 17.17 H 1.54 1.63 1.42 1.97 I 3.44 3.54 4.49 6.5 J 4.61 4.61 4.61 4.61 K 6.89 7.09 8.98 4.61 L 4.92 4.92 4.92 12.99 M 6.5 6.5 6.5 4.92 N 5.51 5.51 5.51 6.5 O 0.73 0.73 1.02 1.38 P 2.46 Dimensions in inches Line Neutral MASTER-SLAVE interlock wiring schematic for sequential backwash signal release MASTER VALVE MASTER VALVE SLAVE VALVE 19 18 12 11 MASTER-SLAVE pump interlock schematic SLAVE VALVE 14 13 14 13 coil pump 1 1/2 " SM FLOW RATE (GPM) 20 30 40 50 60 70 80 APP'X HEAD LOSS (PSI) 0.8 1.5 2.5 3.8 5.0 6.5 8.0 2" SM FLOW RATE (GPM) 70 80 90 100 110 120 130 140 APP'X HEAD LOSS (PSI) 3.2 4.3 5.5 6.6 8.2 10.0 11.0 12.0 3" SM FLOW RATE (GPM) 170 185 200 220 240 255 270 300 310 340 APP'X HEAD LOSS (PSI) 1.6 2.0 2.6 3.0 3.5 4.0 4.8 5.5 6.2 7.0

Sequence of automatic backwash cycle Internally Requires touch pad controlled relays 1 2 3 4 5 6 7 8 9 activation Trigger of Delay Cycle Travel* Back Travel* Rinsing Travel* FILTER DRAIN RECIRC. back wash Time Start 45 sec Washing 35 sec 25 s. - 200 s. 25 sec position position position cycle 25 s. -25 m. 50 s. - 9 m. A 13/14 max 8 contacts contacts contacts contacts contacts contacts contacts contacts contacts contacts contacts Amp closed/ closed/ open / open / closed/ open / pump closed/ open / pump closed/ closed/ closed/ pump on pump on pump off pump off pump on off pump on off pump on pump on pump on B AQUASTAR C6 RELAY SEQUENCING CHART 4/G/3 max 8 Amp G-4 closed G-4 closed G-4 closed G-4 closed G-4 closed G-4 closed G-4 closed G-4 closed G-3 closed G-4 closed G-3 closed C 26/27 contacts contacts contacts contacts contacts contacts contacts contacts contacts contacts contacts max 4 Amp open open open open closed open open open open open open D 24/25 contacts contacts contacts contacts contacts contacts contacts contacts contacts contacts contacts max 4 Amp open open open open open open closed open open open open E 29/30 contacts contacts contacts contacts contacts contacts contacts contacts contacts contacts contacts max 4 Amp open open open open open open open open open open closed F 31/32 contacts contacts contacts contacts contacts contacts contacts contacts contacts contacts contacts max 4 Amp open open open open open open open open open closed open G 21/22 contacts contacts contacts contacts contacts contacts contacts contacts contacts contacts contacts max 4 Amp open / open / open / open / open / open / open / open / closed / open / open / heater off heater off heater off heater off heater off heater off heater off heater off heater on heater off heater off H 18/19/20 max 19/20 closed 4 Amp serial signal will connection of start second multiple Aqua 19/20 19/20 18/19 18/19 18/19 18/19 18/19 18/19 actuator 19/20 19/20 Stars closed closed closed closed closed closed closed closed cycle closed closed * that column represents actuator travel between positions ROW A: Pump interlock control relay Terminals 13 and 14. It shows the switching state of relay during entire backwash cycle. ROW B: SPDT relay state during entire back wash cycle. This is typically used to control 3-Way valves. ROW C: Relay terminals 26-27 are closed on the backwash position. It is therefore ideally suited for controlling extra equipment in backwash position only. ROW D: Relay terminals 24-25 are closed in RINSE position. It is therefore ideally suited for controlling auxiliary equipment in Rinse position only. ROW E: Relay terminals 29-30 are normally open. These relay contacts are N/C only in RECIRCULATION (FILTER BYPASS mode) positions. ROW F: Relay terminals 31-32 are normally open. These relay contacts are only closed in the DRAIN position. ROW G: Relay terminals 21-22 are normally open. These contacts are N/C in filter mode. This relay is typically used to control pool heater shut down. ROW H: The sequencing relay terminals of relay 19/20/18 which is a SPDT relay, is typically used for multiple valve sequencing such as initiating a secondary Aquastar controller to start a backwash cycle after the present valve has completed it's cycle. Column 1: Switching positions of all relays while the actuator is receiving the signal from either a pressure switch or other sources (timers) to start the backwash cycle. Column 2: Switching positions of all relays while the internal fireman delay timer (20 sec to 25 min) is counting down to zero to release the cycle start. Column 3: Switching positions of all relays when the cycle start signal is being released in the controllers electronics. A 30 second start delay holds back the motors from moving at this point. Column 4: Switching positions of all relays while the actuator is travelling from FILTER position to BACKWASH position. 25 second duration. Column 5-9: Shows rest of automatic cycle. PRAHER VALVES LTD. 101 Saunders Road, Barrie, ON L4N 6E7 Canada Tel: 705-725-1100 Fax: 705-725-0444 US SALES & MARKETING: Tel: 800 461-4915 Fax: 512 240-4488 www.prahervalves.com