COMBINATION FIRE/SMOKE DAMPER - CLASS F MODEL BMFSD (3 HR) / MODEL BEMFSD (1½ HR)

Similar documents
SMOKE DAMPER - CLASS F MODEL BMSD

PRODUCTS BULLETIN PRODUCTS CATALOGUE

CFSD Series. Product Description

Motorized Fire Dampers

LLOYD INDUSTRIES INC.

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

INSTALLATION INSTRUCTIONS MODEL KFD-555

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

Model FSD-212. Combination FIRE SMOKE DAMPERS

Fire Dampers Catalogue

FSD60/MFSD60 Multi-blade Fire Damper

Standard Installation Combination Fire/Smoke Damper Models: FS1, FS2, FT1, FT2, FA1, FA2, TA1, TA2 Fire Damper Models: MD19, MD39, MA19, MA39

Model FSD-331 Combination Fire Smoke Dampers

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Standard Installation Combination Fire/Smoke Damper Models: FS1(SS), FS2(SS) Fire Damper Models: MD19(SS)

Fire, Smoke, and Combination Fire Smoke Dampers

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features

Standard Installation Combination Fire/Smoke Damper Models: FS1, FS2, FT1, FT2, FA1, FA2, TA1, TA2, FS2C2 Fire Damper Models: MD19, MD39, MA19, MA39

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

B. Fabricate in accordance with ASHRAE handbooks and SMACNA duct manuals. A. Submit in accordance with Division-1 and Section

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

Standard Installation Fire/Smoke Damper Models: FR1, FR2 Smoke Damper Models: SR1, SR2

Standard Installation Fire Damper Models: 319, 319(SS), D39

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

DAMPERS WE CONTROL AIR

BC 03. Fire Dampers FD-GB-30-AS LISTED

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2

MODEL 151B FIRE DAMPER

Dampers. Louvers. Caring for Human Life & Property (FIRE, SMOKE & HVAC) NAFFCOFlow.com

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )

Series HCD Airfoil Control Damper

A. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR

BC Motorized Fire Smoke Dampers MSFD-GB-30C1-A MSFD-GB-30C1-A LISTED

VCD-23 Low Leakage CONTROL DAMPER

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Model FD-350. Static Rated Fire Dampers 3 Hour Fire Resistance Rating. Application. Ratings. Construction Standard Optional.

Installation, Operation and Maintenance Manual

INDEX. Chapter1 6. air master. Volume Control Dampers

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

CURTAIN TYPE FIRE DAMPER

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories.

Model DFD-350. Dynamic Rated Fire Damper 3 Hour Fire Resistance Rating. Application. Ratings. Optional Features

MOTORIZED VOLUME DAMPER

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

Part # Installation,Operation and Maintenance Instructions

MULTI-BLADE FIRE DAMPERS

AMCA International. Guide for Commissioning and Periodic Performance Testing of Fire, Smoke and Other Life Safety Related Dampers

series FSD-FLD Fire and smoke dampers UL Approval

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

Fusible Link (replaceable) Horizontal Mount

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

VCD-23. Flange Options. Size Limitations

Installation, Operation and Maintenance Manual

ARROW INDUSTRIAL PRODUCTS

RECEIVING AND HANDLING INSTALLATION SUPPLEMENTS WARRANTY SAFETY WARNING:

table of contents PRODUCT SUMMARY 2

Model VCD-20 3V CONTROL DAMPER

VCD-23. Low Leakage CONTROL DAMPER

FIREGARD GILBERTS. Curtain Fire Dampers FEATURES DAMPERS 4 SFB (57.9) X UDC AUGUST 2006

HCD-230 Industrial Control Damper

Smoke Dampers. Installation Instructions

FIREGARD GILBERTS. Curtain Fire Dampers FEATURES

MULTI-BLADE FIRE DAMPERS

CCS Zone/Bypass Damper Assembly

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

ARROW UNITED INDUSTRIES

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

AIR DUCT ACCESSORIES

AMD-33 Air Measuring Station with VCD-33 Control Damper

VOLUME CONTROL & SHUT OFF DAMPERS SERIES 400

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

CONTROL DAMPERS. Models 1810 & Model Model Model 1370

VOLUME CONTROL DAMPERS

EnergyShield ES. Air Control and Shut off Dampers. Dampers Controls Fancoils. Ruskin Air Management Limited

Life Safety Dampers. Fire Combination Fire Smoke Smoke Ceiling Radiation

Zero Leakage Isolation Damper

HEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L SERIES

Introduction to Johnson Controls Dampers

POWERS Controls. Technical Instructions Document No P25 AP December 3, No. 6 Pneumatic Damper Actuator.

When Time is Everything... We Manufacture in Days - Not Weeks!

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING

Shutter Fire Damper Type FSD GFSD 4/1.1/B/1

Fusible Link (replaceable) Horizontal Mount

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

YCCS Zone/Bypass Damper Assembly

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7

YCCS Zone/Bypass Damper Assembly

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

POWERS Controls No. 4 Pneumatic Damper Actuator

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure:

Control Dampers. Leakage Performance. Model FDNB (Opposed Blade) FDQB (Parallel Blade) Galvanized 3V Blade Control Dampers

Transcription:

UL CLASSIFIED DAMPERS COMBINED FIRE/SMOKE DAMPER - BMFSD SERIES STANDARD CONSTRUCTION Standards: Designed and tested in accordance with UL555 & UL555S. Meets NFPA 90A and SMACNA requirements for fire & smoke dampers. Application: For fire & smoke barriers in dynamic fire & smoke management systems. Frame: Blades: Bushes: Axles: Linkage: 133mm Roll formed hat-shaped made of 1.4mm thick galvanized steel with reinforced corners, having integral bracing and 90 perpendicular overlap at a corner. Roll formed 3 V-shaped made of 1.4mm thick galvanized steel. Bronze bushes. " Square axles made of galvanized steel. Mechanical and concealed in frame. Drive : ½" Round Jack Shaft made of galvanized steel. Jamb Seals: Stainless steel jamb seals. Models BMFSD-T & BEMFSD-T Blades Seals: UL listed high-temperature (exceeding 450 F) Silicone blades edges seal/gasket manufactured in accordance with UL555S requirements. Temperature Responsive Device: Resettable Thermoelectric set at 165 F. Actuator: Sleeve: Mounting: A UL listed HONEYWELL 9 Nm actuator for each single section damper up to 36"X36". Sleeve made of 400mm depth and 1.1mm thickness galvanized steel. Vertical mounting. Fire Rating: 3 hr (Model BMFSD). Air Flow Rating: 2000 FPM / 4 IWG. OPTIONS Sizes: Single Section: Max. 36" X 36" Multiple Section: Max. 72" X 72" 35

COMBINED FIRE/SMOKE DAMPER - BMFSD SERIES UL CLASSIFIED DAMPERS OPTIONS Fire Rating: 1½ hr (Model BEMFSD). Without Sleeve. With one side plate only (Models BMFSD-XS & BEMFSD-XS). Round spigots for models BMFSD/R and BEMFSD/R. FEATURE MODEL BMFSD-T BMFSD/R-T BEMFSD-T BEMFSD/R-T USE FIRE BARRIER SMOKE BARRIER SYSTEM STATIC DYNAMIC AIR FLOW RATING 2000 FPM PRESSURE RATING 4 IWG Models BMFSD/R & BEMFSD/R LEAKAGE CLASS CLASS 2-250 F FIRE RATING 3 HR 1½ HR MOTORIZED ROUND SPIGOTS NO YES WITH TEMPERATURE RESPONSIVE DEVICE "165 F RESETTABLE THERMOELECTRIC TRD" Models BMFSD-XS & BEMFSD-XS WITH SLEEVE ABOVE MODELS ROUND SPIGOT CAN BE SLEEVE & WITH ONE SIDE PLATE WHEN THE MODEL ENDS BY "-XS" 36

UL CLASSIFIED DAMPERS COMBINED FIRE/SMOKE DAMPER - BMFSD SERIES ASSEMBLY Single section assembly up to 36 X36 (915X915mm) A JAMB seal Square Rod Jack shaft Top Section View UL Listed actuator Bronze Bush Steel Rivet Blade Single skin 3-V Groove Detail - A H TRD(OEM) without fusible link Smoke Seal (gasket) TRD(OEM) UL Listed Actuator Sleeve H W Front View Multiple section assembly up to 72 X72 (1830X1830mm) A JAMB seal Square Rod Side Section View ul listed actuator Jack Shaft Top Section View WIDTH ul listed actuator Bronze Bush Steel Rivet Detail - A TRD (OEM) without fusible link TRD (OEM) UL Listed Actuator HEIGHT Sections are joined by steel rivets without fusible link UL Listed Actuator SLEEVE Front View Side Section View 37

COMBINED FIRE/SMOKE DAMPER - BMFSD SERIES UL CLASSIFIED DAMPERS PERFORMANCE DATA ORDERING KEY B MFSD /R8 -T SIZE XS B: 3 HRS RATED BE: 1½ HRS RATED MOTORIZED COMBINED FIRE & SMOKE DAMPER --: ROUND SPIGOT /Rd: WITH ROUND SPIGOTS OF d DIA. ( d IS DIAMETER IN INCH UP TO 32 ) -T: WITH RESETTABLE THERMOELECTRIC 165OF TEMPERATURE RESPONSIVE DEVICE (TRD) SIZE: WIDTH X HEIGHT --: WITH SLEEVE (STANDARD) XS: SLEEVE 38

UL CLASSIFIED DAMPERS COMBINED FIRE/SMOKE DAMPER - BMFSD SERIES INSTALLATION (E) INSTALLATION AND OPERATING INSTRUCTIONS FOR MODELS BMFSD-T, BEMFSD-T, BMFSD/R-T & BEMFSD/R-T 1) The damper ( 1 ) should be installed vertical, centrally and resting on the bottom opening within the surrounding masonry / gypsum wall (7). Actuator should be out of wall / gypsum partition as shown in ( figure 1 ). 2) The damper ( 1 ) should be installed in a rectangular galvanized steel sleeve ( 2 ) with a minimum thickness of 1.1mm. This sleeve should be attached to the damper using M6 bolts ( 5 ) and spaced at not more than 110 mm centers and 30 mm from corners. 3) Clearance requirements for damper sleeves within a wall opening are based on 1/8 inch per foot ( 10mm per meter) of width or heigth unless otherwise stated in the listing of the assembly. 4) The sleeve ( 2 ) should be of suitable length to extend through the wall to enable the fitting of the cover angles and ductwork. Minimum of 90 mm from the wall and total depth of the sleeve should not exceed more than 510 mm. 5) The retaining angles ( 3 ) should be attached to the sleeve by 6 mm dia ( 4 ) bolts at a maximum of 110 mm centers, and should form a complete frame around the sleeve and cover over the expansion space ( 6 ) required between sleeve and wall opening. The four corner of the retaining angles are not to be welded. The bolts connecting the retaining angles to the sleeve to be 30mm maximum from the corners. Retaining angles will be send in loose parts. Note: The retaining angles bolts should be out of the area of the damper frame. 6) The retaining angles ( 3 ) should be of such a size as always to form an overlap with the wall by 25mm minimum and should be manufactured from a minimum size of 35 x 35 x 1.5 mm Gl. 7) Push the re-set button to reset the TRD 165 F. 8) The duct-sleeve connection to be of as per listed in UL 555s. Connecting ducts shall not be continuous and shall terminate at the sleeve. Installation shall comply with NFPA 90A. 9) All fixing of frames must be positioned clear of the damper blade path so as not to impede proper closure. 7 Surrounding Masonry/Gypsum or wall / partition 6 Expansion Space 5 Bolt Retaining Angles 35 x 35 x 1.5 M6 Bolt & Nut 4 3 Blade Single skin 3-V Groove TRD(OEM) Damper Assy 1 UL Listed Actuator 2 SLEEVE Smoke Seal (gasket) DUCT by others DUCT SLEEVE connection 510 mm maximum FIGURE 1 39

COMBINED FIRE/SMOKE DAMPER - BMFSD SERIES UL CLASSIFIED DAMPERS EXPLODED ASSEMBLY WITH SLEEVE: INSTALLATION ASSEMBLY PROCEDURES: 1- Fix the damper A into the sleeve B matching their hole provision using rivets/bolts. 2- Fix the damper with sleev into the concrete/gypsum wall opening E using the front retaining angle C 35X35 and matching their hole provision using M6 Hex bolt & nut. The sleeve B must overhang by a minimum of 90mm and maximum of 152mm. Opening size should have clearance of 3mm per 305mm of width and height. 3- Finally, when the subassembly is already fitted to the wall, fix the back retaining angle D 35X35 using M6 Hex bolt & nut. DUCT-SLEEVE CONNECTIONS FLANGED BREAKWAY CONNECTIONS: TRANSVERSE JOINTS BREAKWAY CONNECTIONS ( FLANGES): HEMMED S SUP INSIDE SUP JOINT DOUBLE S SUP PLAIN S SLIP STANDING S SUP STANDING S SLIP (ALTERNATE BAR) STANDING S SLIP (ANGLE REINFORCED) STANDING S SLIP (BAR REINFORCED 40