CONTENTS APM ELECTRONIC WEIGHING INDICATOR OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS 3. KEYBOARD LAYOUT AND DESCRIPTION 4.

Similar documents
NGW & HGW SERIES CONTENTS OPERATION MANUAL CAUTIONS HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE 1. INSTALLATION 2. SPECIFICATIONS

SAC SERIES CONTENTS TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS

CONTENTS OPERATION MANUAL BENCH/FLOOR SCALE 1 INSTALLATION 2 SPECIFICATIONS

HS SERIES ELECTRONIC HANGING SCALE CONTENTS OPERATION MANUAL 1. OPERATING PRECAUTIONS 2. KEYBOARD LAYOUT AND DESCRIPTION 3. INSTRUCTIONS FOR USE

Quick Guide. brite Advanced Retail scale

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

Weighing Scale IDS-802. User Manual

OPERATIONS MANUAL M-520. Please take the time to read these instructions before starting to use the scales. Page 1

Price Computing Scale D Series Operation Manual

MARINER MODEL WPS12 WATERPROOF DIGITAL PORTION SCALE OWNER S MANUAL

Valor 2000 Series Instruction Manual

TP Series OWNER S MANUAL. Price Computing Scale (VER.2)

b3c OPERATING MANUAL (GB) 9260(A) (A) 9360 Compacts scales 9260 (A) Ver 2014 EN September BC

Compact Scales. Software Revision V1.25 & above

Ohaus ES Series Bench Scale

1. Introduction Specifications Operation Guide Trouble shooting Note... 13

USER S MANUAL G SERIES USER S MANUAL. Ref.49-MG000EN08

TYPE 41LA MINING LED LUMINAIRE EXPLOSION PROOF LUMINAIRE WITH FLAMEPROOF PROTECTION (TYPE d)

FX 220 User Instructions

OCS Series. High Resolution Digital Crane Scale. User Guide

Adam Equipment WBW & WBW-M SERIES. (P.N , Revision A2, November 2011)

UK Weighing Federation Technical Articles

Defender 3000 Series Base Instruction Manual

User Instruction Manual Oxford Classic Digital Weigh Scale. To avoid injury, read user manual prior to use.

USER MANUAL iforks. Rev USER MANUAL iforks 1

Easy Weigh ADVANCED COUNTING SCALE MODEL: AC-100 OWNER S MANUAL VER 1.00

OCS-T High Resolution Digital Crane Scale

Catapult 1000 Series Instruction Manual

MODEL PS-4 DIGITAL PORTION SCALE

OVERVIEW OF CONTROLS

Price Computing Scale DS Series Operation Manual

Weighing Indicator TM701 Handrail scales

GRAVITY MEASUREMENT, INC.

ITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance

Assembly instructions WAES

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013)

KILOTECH. KWD 500 Water tight. Portion/Weighing Scale

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

ECONOMY COUNTING SCALE OPERATION & SERVICE MANUAL

OIML CERTIFICATE OF CONFORMITY

Model 8000XL OPERATOR MANUAL

NPS Series. Pallet Jack Scale Operator s Guide (V1611)

ECONOMY CRANE SCALE OPERATION & SERVICE MANUAL

CITIZEN. series. Precision Balances

FOR YOUR PERMANENT FILE

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

Electronic Crane Scale

APD: Bench scale with weight indicator which can be mounted attached to the platform or can be mobile.

SAFETY GUIDE...4 PRECAUTION...4 PRODUCT CHARACTERISTICS...5 SPECIFICATION...5 MODEL...6 SIZE AND NET WEIGHT...7 OPERATION...8

SSP-Series Portable Balances Operation Manual

CS-250 Series. CHAIR SCALE SERVICE MANUAL (v1.06d)

Model DS7060 Handrail Scale. User Manual

Charder. Medical scale. User instruction. Important information. This user instruction must be read before the medical scale is used.

Digital Scale. Revision 1.0 August 17, Contents subject to change without notice.

(((temporary title page))) Please read these instructions before using your FS/GS HUSKY FS/GS USER LEAFLET

Operating manual FP-2. Index

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

American Weigh Scales SG-300. User Manual. SG-300 (300g x 0.1g) Copyright 2012 American Weigh Scales, Inc. All rights reserved. Rev. 2.

Virtual Measurements & Control. VC210 Operators Manual

Adam Equipment QT SERIES. ADAM EQUIPMENT CO. LTD. pn Rev. D1, July 2002

RoboSterz. Automatic Management of Steering Without Operator ITA. Mod. V.

T29 series. Wash Down S cale. Technical Manual. TotalcompR. Scales & Components

TYPE NO. AS APPROPRIATE

XK3190- A7. Weighing indicator USER MANUAL

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display

OWNERS MANUAL iforks. Rev OWNERS MANUAL iforks 1

User Manual. Rev USER MANUAL MForks 1

RD712 & RD712XL Remote Displays. Model 615 / 615XL Indicator User s Manual

DIGITAL CRANE SCALE MODEL: OCS-S9 USER MANUAL

PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL USA From outside US: +1 Tel: (561) Fax: (561)

Model 7400 OPERATOR MANUAL

SL101 Manual_SL101 User Manual 05/10/ :06 Page 1. Instruction Manual

SERIES (with EC type Approval) (P.N. 6315, Rev. C7, July 2011)

Navigator TM Series Balances Instruction Manual

Adam Equipment. WBW SERIES WBW..M EC and WBW..aM NTEP Type Approved (P.N , Revision E4, May 2013)

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

PORT-A-WEIGH CRANE SCALES

RFID114. For use in combination with charge controllers used in electric vehicle charging stations, wall boxes or street light charging points.

SPC Series. Digital Scale. Operation Manual

LE.3k Operation Manual

Table of contents. 1. Overview Features & Specifications Keypad Operation General Scale Operations Battery Charging.

USER GUIDE. Model RH10 Hygro Thermometer. Humidity and Temperature Meter

Operator Manual. brite Standard Retail scale

Digital Diesel Control Remote control panel for GENVERTER GV4 and GV7i

DIGITAL PHYSICIAN Waist-High Scale Models 8430, 8431 & 8437 Operating Instructions

Instruction Manual Recharging Aids and Dock

Operating manual Platform/floor scales

FOR YOUR PERMANENT FILE

Adam Equipment CPW COMPACT SCALE

INSTRUCTION MANUAL VISCOTESTER VT-05 / VT-06 PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

EC Type-Approval Certificate UK 2655 Revision 2

SafetyPAT Plus A B P/N:

Patient Lift Scale Indicator Owner s Manual

Dip Tester Model DS-03

E-MCR-05 Media Converter Rack User s Guide

POCKET-TACH 100 MONARCH INSTRUMENT Rev 1.4. Instruction Manual. Printed in the U.S.A. Monarch Instrument 2001 all rights reserved

Heat Meter Integrator

Table of Contents. CLS-420 Wireless Version. CLS-920i Wired Version. CLS-920i Wireless Version. lift truck CLS-420 Wired Version

RFID110-L1. For use in combination with charge controllers used in electric vehicle charging stations, wall boxes and street light charging points

Transcription:

APM ELECTRONIC WEIGHING INDICATOR CONTENTS 1. INSTALLATION OPERATION MANUAL 2. SPECIFICATIONS 3. KEYBOARD LAYOUT AND DESCRIPTION PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THIS INDICATOR 4. INITIAL SETUP 5. INSTRUCTION FOR USE 6. TROUBLE SHOOTING 7. DAILY CARE AND MAINTENANCE APPENDIX: ERROR CODES DECEMBER 2003 REV 3 Specifications subject to change without prior notice

1. INSTALLATION Because of metrological legislation, installation/some metrological parameter settings are limited to be done by authorized personnel only. Do not attempt to change any of the built-in parameters. Contact your dealer for installation and technical assistance. CAUTION: This unit is legal for trade only when it is sealed (and/or stamped) and bearing a serial number. Do not attempt to break the seal (or stamp) affixed to this indicator or remove the serial number. Contact your dealer for more information and after sales service. For most accurate weighing result, do not use the indicator in where or when the environment condition falls beyond as those listed on SPECIFICATIONS. Do not attempt to open this unit or conduct any trouble shootings other than those listed on TROUBLE SHOOTING. 2. SPECIFICATIONS Model No. APM INDICATOR Max. 6kg, 15kg, 30kg, 60kg, 150kg n max (OIML) 3000 n max (Non-OIML) 3000 or 6000/7500 Tare Range 1/3 Max. e Power-on Zero Range Ó10% Max. Zero Range Ó2% Max. Min. Load 20e Max. measuring range 9.0mV Min. signal voltage per verification scale interval 1.5 V Power source BY EXTERNAL POWER ADAPTOR OR RECHARGEABLE BATTERY Minimum battery voltage 5.5 VDC Load cell Excitation voltage 5 VDC Minimal load cell impedance 85 Maximal load cell impedance 1000 Load cell connection 4-wire Operation Environment 0 o ~40 o C (32 o ~104 o F) Non-condensed. R.H. 85% Specifications subject to change without notice. NOTE: OIML = Legal for trade (1/3000) Non-OIML = Not legal for trade (1/3000 or 1/6000~1/7500)

3. KEYBOARD LAYOUT AND DESCRIPTION 7. MC KEY Press MR and ZERO simultaneously to clear weight from memory. 8. LO BAT INDICATOR This indicator appears when input voltage is below the lowest input limit. Check the power supplied to the indicator. 9. ZERO INDICATOR This indicator appears to indicate zero weight status. 1. ON/OFF KEY Press this key to turn indicator on or off. 2. MODE KEY Press this key to shift among different weight units and/or turn backlight on/off. 3. TARE KEY Press this key to tare off the weight of a container. 4. ZERO KEY Press this key to set weight displayed to zero. 5. M+ KEY Press this key to accumulate current weight to memory. 10. NET INDICATOR This indicator appears to indicate the tare function is in operation and weight shown is net weight. 11. M+ INDICATOR This indicator appears to indicate memory contains of stored data. 12. MR INDICATOR This indicator appears to indicate the value shown is the total accumulated weight stored. 13. WEIGHT UNIT INDICATOR The current weight unit is displayed here. 6. MR KEY Press this key to recall the total accumulated weight from memory.

4. INITIAL SETUP 4.1 PLACING THE SCALE In order to obtain an accurate weighing result, the complete weighing instrument (hereinafter referred as the scale) must be placed on a strong and level surface. If required, adjust the adjustable feet underneath scale to obtain a level position. Refer to the bubble indicator for leveling condition. 4.2 INTERNAL SETTING 4.2.1 Display Segment Check User can enter this function to check to see if the display and backlight (if purchased) are functioning properly. a. Scale is off b. Press and hold TARE, then press ON/OFF c. Scale displays F.1 d. Press TARE once e. Scale displays F.2 f. Press MODE and all segments will light up to allow user to check the condition of display g. Press TARE to quit and ON/ZERO to restart the scale 4.2.2 Select Auto Power Off Setting The scale is equipped with Auto Power Off Function. The scale will power off automatically if it is not used for 4 minutes. Follow the below steps to enable/disable Auto Power Off Function. a. Scale is off b. Press and hold TARE, then press ON/OFF c. Scale displays F.1 d. Press TARE three times e. Scale displays F.4 f. Press MODE to shift between 0_OFF and 4_OFF -To enable Auto Power Off Function, press TARE when 4_OFF appears -To disable Auto Power Off Function, press TARE when 0_OFF appears g. Press ZERO to restart the scale or TARE for next function setup 4.2.3 Select Auto Tare Function This scale is equipped with auto tare function which tares off the initial weight automatically when this function is engaged. The tare weight is automatically cleared when everything is removed from platter. a. Scale is off

b. Press and hold TARE, then press ON/OFF c. Scale displays F.1 d. Press TARE four times e. Scale displays F.9 f. Press MODE to select between Tr_on or TroFF -To enable Auto Tare Function, press TARE when Tr_on appears -To disable Auto Tare Function, press TARE when TroFF appears g. Press TARE for next function setup or ZERO to restart the scale 5. INSTRUCTION FOR USE 5.1 BEFORE WEIGHING Make sure that: a. Connect the load cell signal and power to the indicator properly. b. Place the scale on a level and strong surface. c. The indicator is turned on. d. The ZERO INDICATOR is on. If not, press ZERO to set display to zero. 5.2 WEIGHING a. Always place an object onto the scale gently. Excessive force applied to platter may cause damages to weight sensor. b. The weight of the object is displayed on the indicator automatically. c. It is a good practice to remove all loads from scale after weighing. It would prolong the lifetime of weight sensor. 5.3 SELECT WEIGHT UNIT Press MODE to shift between metric or avoirdupois weight units. The weight unit used before power off would be employed when the scale is turned on again.

NOTE: To comply with the law of certain countries and certain approval requirements, the avoirdupois weight units may be disabled. Contact your dealer for more information. 5.4 TURN BACKLIGHT (OPTIONAL) ON/OFF Follow the below steps to turn on and off backlight (if purchased). a. Scale is on b. Press and hold ZERO until backlight is activated; or press MODE to shift between metric and avoirdupois weight to turn on and off backlight Even though the backlight function is employed, backlight will be automatically turned off when a stable weight remained for 25 seconds or a zero weight is detected and remains stable for 10 seconds Backlight will be automatically turned on again when a new weight is detected or when any key is pressed. 5.5 SET DISPLAYED VALUE TO ZERO WHEN UNLOADED By pressing ZERO, weight displayed will be set to zero and ZERO INDICATOR appears. Refer to SPECIFICATIONS for maximum zero range. NOTE: -When scale is set at OIML and application is legal for trade. User only needs to press ON/ZERO once when setting the value to zero. The re-zero function will take place when reading is stabled -When scale is set at Non-OIML and application is not legal for trade. User can set the value to zero at anytime when pressing ON/ZERO 5.6 TARE OFF THE WEIGHT OF A CONTAINER When a container is used, follow the below steps to manually tare off the weight of container and get the net weight. a. Remove all loads away from platter b. Make sure that the ZERO INDICATOR is on. c. Place the container on the platter. d. Press TARE. After TARE is pressed, the NET INDICATOR would appear. Refer to 5.2 for weighing procedures. Weight displayed under is the net weight of the subject matter. Refer

to SPECIFICATIONS for maximum tare range. NOTE: - When scale is set at OIML and application is legal for trade. User only needs to press TARE once when tare off a weight. The tare function will take place when reading is stabled - When scale is set at Non-OIML and application is not legal for trade. User can tare off the weight anytime when pressing TARE 5.7 CLEAR THE TARE FUNCTION a. Remove all loads from platter b. The tare effect will be cancelled: -Automatically if automatic tare function is employed, or -By pressing TARE c. After TARE is pressed, the NET INDICATOR would disappear. 5.8 MEMORY FUNCTION 5.8.1 Accumulate a Transaction To Memory a. Refer to 5.2 for weighing producers. b. Press M+ to save and accumulate data of current transaction to memory. c. Indicator displays P. 1 andm+ INDICATOR appears to indicate that memory contains of stored data. NOTE: P.? means the total number of transactions accumulated to memory. d. Indicator returns to normal display status after 2 seconds. e. Repeat a to c for subsequent transactions. NOTE: - When scale is set at OIML and application is legal for trade. User only needs to press M+ once when trying to store a value to memory. The weight accumulation function will take place when reading is stabled - When scale is set at Non-OIML and application is not legal for trade. User can save the shown value to memory at anytime when pressing M+ 5.8.2 Memory Recall Press MR to recall total accumulated weight from memory. After MR is pressed, indicator displays P.? (? Means the number of transactions accumulated), then a flashing value. The flashing value is the total accumulated weight stored in memory.

When the total accumulated weight is being displayed, MR INDICATOR appears to indicator that the value being displayed is the accumulated weight. Indicator returns to normal display status after 3 seconds. 5.9.2 In case a Power Adaptor is Used Check power supply to indicator immediately. NOTE: If LO BAT status is detected during power on, indicator shows P-OFF and the indicator will be powered off automatically. 5.8.3 Memory Clear All transactions stored in memory by pressing MR and ZERO simultaneously. CAUTION: All data stored will be erased when the indicator is turned/powered off. 5.9 LOW BATTERY The low battery sign appears when input voltage is below the lowest input limit. Please recharge the scale immediately. Failure to do so may cause unrecoverable damage to the rechargeable battery. 5.9.1 In case a Rechargeable is Used The indicator will be power off in about 5 to 10 minutes. Recharge the battery now.

6. TROUBLE SHOOTING Syndrome Indicator cannot be turned on Check: Is the indicator powered properly? Action: Check power supply to indicator. Syndrome Indicator turned off automatically Check Is Auto Power Off Function employed? Action Refer to 4.2.2 to disable Auto Power Off Function. Check Is the LO-BAT INDICATOR on? Action Check power supply. Syndrome Rated capacity cannot be reached Check Is the NET INDICATOR on? Action: Turn the indicator off. Remove all loads and turn on again. Check Is there anything obstructing the scale? Action Remove all obstacles. Syndrome Blank display with only "kg" or "lb" Check Is the load applied to scale excess the rated capacity? Action Remove all loads and try again. Syndrome Indicator displays ----- Check Is the load cell signal cables connected to the indicator properly? Action Recheck signal cable connections. Check Is load cell working properly? Action Check load cell input/output. Syndrome Display shows 00000 after counting down Check Is the load applied to platter excess the rated capacity of scale? Action Remove all loads from platter and try again. Syndrome Weighing result is not accurate Check Is the scale placed in a level condition? Action Obtain a level condition. Check Is the scale affected by airflow, vibration or RFI? Action: Place the scale away from all disturbances. Check Is the indicator calibrated correctly? Action Contact your dealer.

7. DAILY CARE AND MAINTENANCE APPENDIX: ERROR CODES 7.1 Clean the indicator with a soft and damp cloth. If necessary, apply a mild detergent. 7.2 Do not use any harsh, abrasive material, acetone, volatile solvent, thinner or alcohol for cleaning. 7.3 Verify the accuracy of indicator periodically. Re-calibrate the indicator if necessary. NOTE: In some countries, calibration requires authorized/qualified agent. Contact your dealer for more information. 7.4 Store indicator scale in a dry and clean place. P_OFF Low battery status is detected during power on. Indicator will shut off after this message appeared. Error Error during calibration. Case 1: The 1 st calibration weight entered is less than 1/3 of rated capacity Case 2: The 2 nd calibration weight entered is over the rated capacity. Case 3: The span value is not within the acceptable range.

KONFORMITATSERKLARUNG Declaration of conformity Declaration de conformite Die ichtselbsttatigen Waage The non-automatic weighing instrument L'instrument de pesage a fonctionnement non automatique Hersteller: Manufacturer: Fabricant Typ/Modell: Type/Model: Type/modele: Nr. der EG-Bauartzulassung (gegebenen falls): No of the EC type-approval certificate (where applicable): No du certificat d'approbation CE de type (le cas echeant): Universal Weight Enterprise Co., Ltd. APM T6125 entspricht dem in der Bescheinigung uber die Bauartzulassung beschriebenen Baumuster, sowie den Anforderungen der EG-Richtlinie 90/384/EWG in der jeweils geltenden Fassung und den Anforderungen folgender EG-Richtlinien: corresponds to the production model described in the EC type-approval certificate and to the requirements of the Council Directive 90/384/EEC as amended and to the requirements of the following EC directives: correspond au modele decrit dans le certificat d'approbation CE de type, aux exigences de la directive 90/384/CEE modifiee et aux exigences des directives CE suivantes: *Diese Erklarung gilt nur in Verbindung mit einer Konformitatsbescheinigung einer benanten Stelle. *This Declaration of conformity is only valid with a certificate of conformity issued by a notified body *Cette declaration est valide seulement avac une aattestation de conformite d un organisme notlfle. Anmerkung 1: Der mit * gekennzeichnete Satz entfailt, wenn die nichtselbsttatige Waage vom Hersteller geeicht wurde. Note 1: The sentence marked with * does not apply, if the non-automatic weighing instrument was verified by the manufacturer. Note 1: La phrasa marquie avac * ne s applique pas au cas ou linstrument de passage a fonctionnement non automatique a eie vaifie par ie fabricant. Unterschrift Signature Signature Datum Date Date