GMZ series Slurry Pump

Similar documents
The ELM Series Slurry Pump Installation and Operating Manual

OPERATION & MAINTENANCE MANUAL HANGZHOU FLYING TECHNOLOGY CO., LTD.

XFLO XS SERIES. Single Stage Double Suction Split Casing Centrifugal Pump

SLOW CENTRIFUGAL PUMP OF DOUBLE-STAGE AND DOUBLE-SUCTION BISECT VOLUTE TYPE

F-800 and F-1000 MUD PUMP Specification and Performance

Grupa Powen-Wafapomp SA. Pumps for Power and Heat Supplying Industries catalogue

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

ZPP and Z22 Double Suction Axially Split Single Stage Centrifugal Pumps

saving compare to screw pump. Less parts, hence Compact design, space Integrated gearbox. easy maintenance. Separate seal chamber, therefore

SLURRY PUMP RANGE. slurrypro.com

Ultra Heavy Duty Slurry Pump Ultra Heavy Duty Slurry Pump

Heavy Duty Slurry Pumps Type Ensival Moret EMW

HDS Centrifugal Slurry pumps

High-speed Centrifugal Pump according to API 610

SLURRY PUMP SLURRY PUMPS PAGE SLURRY PUMPS

Submersible Pumps. pool pumps. Material & Working Limits. Submersible Pump Series - QDX

KSW. KSWR. KSWH. KSWD SERIES SINGLE-STAGE SINGLE-SUCTION HORIZONTAL-TYPE CENTRIFUGAL PUMPS

Vertical Chemical Pumps

MAH HORIZONTAL SLURRY PUMPS

KNIFE GATE VALVES -- MODEL A

Metso pump technologies. Dredge pump program. Heavy duty performance for abrasive materials

SLO, SLOW SERIES SINGLE-STAGE DOUBLE-SUCTION CENTRIFUGAL PUMPS

Water Treatment Plant Maintenance Considerations. Operation and Maintenance. Types of Maintenance 5/1/15

Slurry Pump Range. Keeping mines in motion S40928

GSB-L API-610 Latest Edition

KNIFE GATE VALVES -- MODEL D

Hey-Wel. 3-lobe Roots Blower OPERATION MANUAL

PROCESS PUMPS (INDIA) PVT LTD

Corbrasion resistant, high performance slurry pumps Designed for solids laden waste water to aggressive slurries

EUF/EUFS series. Fire Pump PSB Listed according to CP52(Singapore)

Volute Casing Pumps LSN. according to iso 2828 / iso Jansen Pompentechniek T: +31(0) E:

Installation and Operating Manual

TKL. Hydro-Titan Heavy Duty Back Pull-out Water & Process Liquid Pump. Experience In Motion

End suction back pull-out pumps for general industry, mining, rural and building services

PowerLink GW series Eddy Current Dynamometer User Manual

SFC Serial Constant Filling Fluid Couplings

Data sheet. Page: 1 / 5 ETN GG A 11GA201502B. Operating data. Design. Requested developed head m. Efficiency 74.

AVK SERIES 854 BALL FLOAT VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR BALL FLOAT VALVES

Click on Warman Logo to go back to Menu WARMAN PUMPS ASSEMBLY, OPERATING AND MAINTENANCE INSTRUCTIONS PART 2Q SLURRY JET PUMPS TYPES JPC AND JPH PC2Q

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Pump unit GMZ-E

2BE1 WATER RING VACUUM PUMP

SXHS SLURRY PUMPS VOLUME ONE ISSUED FEBRUARY 20, 2013

Mechanical Seal Presentation April 22, 2009 Seattle WA.

HYDRO-TITAN. Heavy duty back pullout water & process liquid pumps

TECHNICAL HANDBOOK. Heavy Duty ASME B73.1. Wilfley Sealing Technology. No Flush Water Required

Three Lobes Roots Blower. Instruction Manual

Wilfley. Model. Technical Handbook. Centrifugal Slurry Pump

Ductile Iron, Jacketed Pumps: Catalog Section 1602 Cast Iron, Non-Jacketed Pumps: Catalog Section 1401 HL4126A

PROCESS PUMPS (INDIA) PVT LTD

HORIZONTAL MULTI STAGE PUMPS

Bristol: A History & Future.

EJECTORS GENERAL OPERATION & MAINTENANCE MANUAL

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-10 RX-21 RX-25

PROMAG SR SERIES SEAL-LESS CENTRIFUGAL PUMPS

Impeller Replacement

ANSI DIME. Engineered for EXTREME Reliability in Chemical Processes

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

ISO 9001 CERTIFIED COMPANY INDUSTRIAL PUMPS. Installation & Operational Manual For BACK-PULL-OUT PUMP

Bearings. Rolling-contact Bearings

Submersible Turbine Pump (Volute) STM type (T, TU, and TU3) SSTM type (TUA)

General Catalog. A New Vision for Quality Pumps. General Catalog

UNIVERSAL PRODUCT LINE: DUCTILE IRON JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE

IDROCHEMICAL CENTRIFUGAL PUMPS FOR CHEMICAL SERVICE ACCORDING TO ISO 2858 STANDARDS

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-40 RX-63 RX-100

Dry installed pump type LANDY BTP.

PROCESS PUMPS MODEL V200 ANSI B73.2

Data sheet. Customer item no.: Communication dated: Number: ES Doc. no.: Item no.: 100 Quantity: 1 Date: 19/03/2015 Page: 1 / 6

NJK Series ISO Standard End-Suction Centrifugal Pumps

Dry installed end-suction pumps, LSN-series. according to ISO 2858 / ISO 5199

CombiNorm. Centrifugal pump according to EN 733 (DIN 24255)

SP A, SP. Submersible pumps Submersible motors Accessories. 50 Hz

Elite. KSB Australia Pty Ltd. Centrifugal Pump

1 Full Year Factory Warranty SIKO PUMP

Minerals. WARMAN WGR pump

MHH HORIZONTAL SLURRY PUMPS

PumPs. jacketed molten sulfur PumPs. Pumps Mixers Strainers Engineered Systems and Controls.

Orientalmotor. Development of K II Series Hypoid Geared Motor

ABS Dry Installed Waste Water Pumps Series FR

1. SPECIFICATION. Altitude of motor installation. Information: Resistance and temperature specifications of the PTC thermistor / posistor/.

UNIVERSAL PRODUCT LINE: STEEL EXTERNALS JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE

GRUNDFOS DATA BOOKLET SP A, SP. Submersible pumps, motors and accessories 50 Hz

CPS. Horizontal Split Case Centrifugal Pump

S3 General Installation

340 Series Double Suction Split Case Pumps

POC JET - Cartridge Air Filtration System

Table of Contents. AMO series quantitative pressured centralized lubricating system 1. Illustration of AMO motor driven lubricating system 1

Assembly and Maintenance Instructions. Pad Thrust Bearings

Volute Casing Centrifugal Pumps PN 16 for heat-transfer liquids Heat-transfer oil up to 350 C Hot water up to183 C

Index. 4. Installation. 1. General advises

Index. 4. Installation. 1. General advises

LBTC Series Positive Displacement Rotary Vane Flow Meters

- click here for pricing and ordering

The API 610 standard, currently in its 11th edition, covers single stage overhung pumps

Axial Flow Pump Type Ensival Moret CAHR

Volute Casing Pumps LSN. according to iso 2828 / ISO 5199

GENERAL DIMENSIONS OF SMF PUMPS. Capacity upto 7,000 m /hr Head upto 45 m. Range :

3. Fuel System FUEL SYSTEM FUEL INJECTION (FUEL SYSTEM) A: GENERAL. FU(STi)-7

DPL/DPL-AF SERIES PLENUM FANS OPERATION INSTRUCTIONS AND PARTS MANUAL MODELS: DPL/DPL-AF-12, 13, 15, 16, 18, 20, 22, 24, 27, 30, 33, 36 GENERAL SAFETY

IMC-60B Automatic Aluminum Tube Filling & Sealing Machine OPERATION MANUAL

Ver Trunnion Ball Valve INSTALLATION, OPERATION AND MAINTENANCE MANUAL FBV/IOM/BA02

Transcription:

GMZ series Slurry Pump OPERATION MANUAL HL Mud Cleaning Equipment Co.,Ltd

Contents 1. Summarizing 2. Structural Drawing 3. Technical Parameters 4. Points for attention for assembly 5. Operation 6. Care and maintenance 7. Overall dimension 8. Common faults and removal method 9. Flow passage components

1 Summarizing As a single stage single suck and axial sucking cantilever horizontal centrifugal pump, the GMZ series slurry pump can be applied to many industries, such as metallurgy mine electric power desulfurization aeroconcrete chemical engineering and so on. This pump can be used for conveying the corrosive slurry with large quantity solid material. 1 The flow components of GMZ slurry pump adopt high strength and wear resistant material, so it applies to deep-etching high concentration and large particle slurry, and within the maximum working pressure, this pump can be used in multilevel series. 2 According to different sucking medium, the GMZ slurry pump can be changed with different flow components, generally, there are wear-resistant alloy Cr26 Cr 28 No.2 wear-resistant A49 CD4. For the feature of high content chlorine liquid ion in flue gas desulfurization flurry, our company introduced wear-resistant and anticorrosion Cr30, which is the most advanced around the world, from France, in Cr30, the Mo Cr Cu N as well as a certain active elements, it has excellent anti scour as well as better strength and toughness. 3 and meaning: Take GMZ65-20- as example GMZ High efficiency wear-resistance slurry pump 65 Outlet diameter (mm) 20 Pump lift (m) Flow rate (m 3 /h) 2 Structural drawing

Structure specification GMZ series Slurry Pump Except pump head(including pump shell spiral case front and back fender impeller and so on), the rest of GMZ series pump are similar and adopt the same driving mechanism, in the following, given the instruction to pump head shaft gland part and driving part respectively: 1. Pump head: the GMZ series pump is dual-pump shell structure, that is front and back pump shell as well as changeable flow parts (including impeller spiral case front and back fenders), the back and front fender adopt gray pig iron or ductile cast iron for manufacturing, it is open in middle in vertical way and use bolts for connection, there is spigot on the back pump shell and connected with bracket with bolts, additionally, the discharge opening of pump can be installed by eight angles rotation, the back and front cover plates of impeller are equipped with back blade for reducing the leakage, and so the useful life of pump can be improved greatly. Between the impeller and shaft, adopt threaded connection for prevention of reversion. For each kinds of pump, the inlets are designed to be horizontal direction, when seen from the driving direction, it rotates clockwise. 2. Shaft gland part: there are three types for shaft gland, that is auxiliary impeller shaft gland stuffing shaft gland and mechanical sealing. (1) Auxiliary impeller shaft gland: if the single-stage pump or the first stage pump of multilevel series pump whose positive pressure of inlet is no less than 10 % of the outlet value, can use auxiliary impeller shaft gland, because it has the features like no dilution to pulp and good sealing and so on. (2) Stuffing shaft gland: the structure of stuffing shaft gland is simple and easy to maintain, for the industrial and mining district where is not suitable to use auxiliary impeller shaft gland, can adopt stuffing shaft gland. (3) Mechanical sealing: For the place where is not suitable for using the two above shaft glands, can adopt mechanical sealing for reducing the maintenance times of 3. Driving part: for this series pump, adopt the same series driving system including bracket bearing assembly, the pump shaft has many advantages, such as large diameter well rigidity and short cantilever, so there is no deviation and vibration when used in bad environment, choose uniserial conical roller bearing and deep groove ball bearing, with the combination of these two bearings, the maximum axial or radial load can be improved greatly. Additionally, use thin oil for lubricating the bearing and there are end covers at the two ends of bearing body and can prevent the bearing from the pulp pollution, besides, there are two rubber hose connecter, which can be connected with water source, installed onto the bearing body for cooling down the bearing chamber, and so, this pump can be used in high temperature environment without fault and long useful life.

GMZ series slurry pump spectrum diagrams NOTE: this diagram shows the rinsing performance for the reference of initial type selection 3 Technical Parameters Performance and Main Technical Parameters of GMZ Slurry pumps and Other pumps(1) Pump lift (m) Flow rate (m3/h) Rev (r/min) Net positive suction head(m) Efficiency (%) Matching motor Power(KW) 8 10.6 38 GMZ-10-15 15 10 1430 3.5 48 Y100L2-4 3 18 9.7 50 8 16 GMZ50-15-15 15 15 1430 3.5 50 Y100L2-4 3 18 13 49 GMZ50-- 45 65 2950 4.2 50 Y200L1-2 30

GMZ50-- GMZ65-15- GMZ65-20- GMZ-20- GMZ-20-110 GMZ-30-70 GMZ-30-95 53 50 30 85 38 2950 3.5 50 72 70 49 20 16 35 15 970 4.5 50 13.2 47 25 24 43 22 14 4.5 59 21 61 25.1 58 24.4 1470 4 72 100 19.7 69.6 26 64.8 110 22 1470 4.5 70 130 20.6 72 35 37.7 34 70 34 1470 4 52 85 32 54 35 44 34 1470 4 55 100 30 57 GMZ series Slurry Pump Y200L2-2 37 Y1L-6 11 Y1L-4 15 Y1M-4 18.5 Y1M-4 18.5 Y1M-4 18.5 Y1M-4 18.5 Performance and Main Technical Parameters of GMZ Slurry pumps and Other pumps(2) GMZ100-18-170 GMZ100-24-120 GMZ100-24-200 GMZ100-27-1 Pump lift (m) 90 170 200 120 1 100 200 220 70 1 170 Flow rate (m3/h) 21 16 14.5 26.8 24 23 30 25 22 31 27 24 Rev (r/min) Net positive Efficiency suction head (%) (m) 970 4.5 9 4 1470 4.8 1470 4.5 54 56 43 62 66 66.5 84.6 78.5 53 63 62 odel Matching motor Power(KW) Y200L2-6 22 Y225M-6 30 Y200L-4 30 Y200L-4 30 GMZ100-30- 34.2 970 3.5 35 Y200L2-6 22

32.2 55 100 20.2 39.5 35.5 41 GMZ100-30-1 1 33.7 1470 3.8 54.4 Y200L-4 30 1 33 56 100 34 53 GMZ100-30-200 200 30 14 4.8 64 Y225S-4 37 2 28 63 130 38 54 GMZ100-35-250 250 35 14 5 68 Y250M-4 55 300 28 71 30 30 GMZ100--50 50 39 1470 4.5 31 Y1L-4 22 37 36 120 53.7 56 GMZ100--200 170 51 14 4.6 66 Y250M-4 55 200 44 70 Performance and Main Technical Parameters of GMZ Slurry pumps and Other pumps(3) Pump lift (m) Flow rate (m3/h) Rev (r/min) Net positive Efficiency suction head (%) (m) Matching motor Power(KW) 55 34 GMZ-50-120 120 51 14 4.5 52 Y225S-4 37 1 49 43 56 43.3 GMZ100-52- 55 14 4 56 Y225M-4 45 100 53 58 64 21 GMZ100-- 14 4 39 Y225M-4 45 120 62.4 49 90 71.3 33 GMZ100--200 195 69.3 14 4.5 52.4 Y2M-4 90 2 67.3 59 120 78 47 GMZ100-70-1 1 77 14 4.5 58 Y315S-4 110 210 76 63.3 GMZ100--200 100 200 82 14 4.5 31 55 Y315S-4 110

GMZ100-95-250 GMZ100-1-120 GMZ150-25-500 GMZ150-30-320 2 76 56 120 104.8 36 250 102.9 1485 5 63 300 99.3 69 14.48 20 120 142.9 1488 4.5 34 1 1.2 38 300 28 53 500 25 9 5 55 0 20 67 200 29.4 52 320 28.4 9 4.8 67 3 26.9 68 GMZ series Slurry Pump Y315L1-4 1 Y355M3-4 250 Y2M-6 55 Y315S-6 75 Performance and Main Technical Parameters of GMZ Slurry pumps and Other pumps(4) GMZ150-32-0 GMZ150--300 GMZ150--900 GMZ150-45-500 GMZ150-47-2 GMZ150-58-320 GMZ150--450 Pump lift (m) 2 0 4 1 300 3 5 900 10 300 500 5 120 2 300 210 330 390 225 450 5 Flow rate (m3/h) 39.3 36.8 34 43 36 43 37 56.7 53 39 49.3 48.9 47.7 61.1 59.2 57.7 64 61.5 58.7 Rev (r/min) Net positive Efficiency suction head (%) (m) 9 5 9 4.3 990 5 990 5 9 4 9 4.8 990 5 63 75 73 52 66 66 62 70 65 52 63 55 33.3 53.3 58 47 59 62.2 62 75.8 76.6 Matching motor Power(KW) Y315S-6 75 Y315M-6 90 Y355L1-6 220 Y355M1-6 1 Y315M-6 90 Y315L2-6 132 Y355M2-6 1 GMZ150-73-500 300 81 990 5 51 Y355M2-6 185

500 73 56 0 66 2 76 38 GMZ150-75-350 350 75 990 4.8 48 Y355M2-6 185 420 73 52 3 83 44 GMZ150-85-530 542 988 5 54 Y04-6 2 6 77 56 Performance and Main Technical Datas of GMZ Slurry pumps and Other pumps(5) Pump lift (m) Flow rate (m3/h) Rev (r/min) Net positive Efficiency suction (%) head(m) Matching motor Power(KW) 246 90 45 GMZ150-87-410 410 87 990 4.8 62 Y355m4-6 200 492 86 62 1 43 52 GMZ150--300 300 9 4.3 66 Y315M-6 90 3 36 66 5 43 62 GMZ150--900 900 990 5 70 Y355L1-6 220 10 37 65 300 56.7 52 GMZ150-45-500 500 53 990 5 63 Y355M1-6 1 5 39 55 120 49.3 33.3 GMZ150-47-2 2 48.9 9 4 53.3 Y315M-6 90 300 47.7 58 210 61.1 47 GMZ150-58-320 330 59.2 9 4.8 59 Y315L2-6 132 390 57.7 62.2 GMZ150--450 225 450 64 61.5 990 5 62 75.8 Y355M2-6 1

GMZ150-73-500 GMZ150-75-350 GMZ150-85-530 5 58.7 76.6 300 81 51 500 73 990 5 56 0 66 2 76 38 350 75 990 4.8 48 420 73 52 3 83 44 542 988 5 54 6 77 56 GMZ series Slurry Pump Y355M2-6 185 Y355M2-6 185 Y04-6 2 Performance and Main Technical Datas of GMZ Slurry pumps and Other pumps(6) GMZ150-90-0 GMZ150-100-300 GMZ150-120-390 GMZ200-70-550 GMZ200-70-850 GMZ250-14-0 Pump lift (m) 2 0 4 1 300 3 330 390 450 300 550 0 500 850 1020 4 0 9 low rate (m3/h 94 90 86 105 104 102 119 118.2 100.4 74 72 70 74 72 63 16 14 12 Rev (r/min) Net positive suction head (m) 1488 5.2 990 4.5 1488 5 990 5 990 5 7 5 Efficiency (%) 56 65 64 36 50 54 49 53.3 50 45 62 63 51 63 73 74 Matching motor Power(KW) Y255M3-4 250 Y355L3-6 250 355L2-4 2 Y355L1-6 220 Y05-6 315 Y315S-8 55 GMZ250-32-1220 730 37 990 5.5 63 Y355L1-6 220

1220 32 73 14 27 73.5 6 59.7 59 GMZ250-55-1100 1120 56.2 7 5.5 71 Y4506-8 315 13 51.3 69 6 116 55 GMZ250-110-1100 1100 110 990 5.5 65 Y4506-6 630 1320 100 63 12 25 54 GMZ300-22-2100 2100 22 7 6 65 Y4506-8 315 2520 21 66 10 27 51 GMZ300-25-10 10 25 7 5.8 Y07-8 250 21 23 4 Points for attention for assembly 1 Bearing assembly assembling: before assembly, preheat the bearing cone within 120, the deep groove ball bearing must be close to fillet whose two sides are uniserial conical roller bearing. When assembly the uniserial conical roller bearing, adjust the washer at rolling bearing end cap for guarantee of axial clearance, after adjusting, rotate the shaft manually for making the rotate flexibly. 2 Shaft gland assembling: the stuffing shaft gland assembly consists of stuffing-box shaft liner packing ring packing and packing gland and so on. Selection of packing: if the working pressure of pump is under 1MPa, adopt asbestos fibre soaking mica as packing, while the pressure is higher than 1 MPa or convey the corrosive slurry, adopt asbestos fibre soaking polyfluoroethylene as packing. For the mechanical sealing pump, the pump has been debugged before leave factory, there is no need for adjusting by users. 3 Pump head assembling: fasten the back pimp shell onto bracket and install the stuffing-box into back pump shell, then use back fender positioning nuts to install back fender, put the O-ring onto shaft with bond, and install auxiliary impeller as well as spiral case, next, use the bolts and fixed pressing plate to fasten the spiral case onto back pump shell, at last, install the front fender and pump shell, then make the front pump shell and back pump shell be fixed together and screw down the bolts. Additionally, when assemble, put the sealing O-ring of stuffing-box and fender back and front fender and spiral case in correct position and impact it. 5 Operation 1. Startup: before start, check each unit as the following procedure:

GMZ series Slurry Pump (1) The pump shall be installed onto reliable foundation without vibration, then screw down all the anchor bolts. (2) The pipeline and valve shall be equipped with holding frame. When screw down the connecting bolts, the metal liner of some pumps may be higher than flange, so the bolts shall be screwed down properly in case cause damage to sealing washer. (3) Rotate the rotational shaft manually to check is there is any abnormal noise, if any, adjust the clearance of impeller. (4) Check the rotation direction of motor to see if it is the same to the direction of arrow. (5) When direct connection driving, the pump shaft and motor shaft must be centered accurately, and the pump shaft shall be parallel with motor shaft when use belt for driving, and adjust the position of grooved pulley for making it vertical to trough belt in case cause cute vibration and friction. (6) There is one stub tube which can be removed fixed onto the suction pipe of pump, it is convenient to carry out maintenance due to its special structure. (7) Shaft gland inspection: check the water quantity and water pressure in shaft gland to see if they are reasonable; adjust the forcing screw of packing gland for changing the degree of tightness; then adjust the shaft gland, the leakage from packing gland should be seen as blob and blob effusion. The packing should be kept not too tight, otherwise, the shaft liner shall be hot and at the same time, energy consumption shall be increased. While the packing is too loosening, there may be too much leakage, generally, the water pressure of shaft glad shall be higher than pump outlet by 35 KPa. It is suggested that the water quantity of shaft gland shall be controlled at the range of 0.15L/S -2.1L/S according to different model. Additionally, for the pump equipped with mechanical sealing, put through the shaft glad water before open the pump. 2 Running (1) In the process of running, check the pressure and flow rate of water in shaft gland frequently and adjust the packing gland or change the packing for ensuring there is less clean water going through the shaft. (2) Check the running condition of bearing assembly, before start the pump, add #20 or 30 lubrication oil into bearing body, and connect the rubber hose connecter with cold water (No need for cold water for 18.5KW below). The oil quantity of bearing shall be proper and clean and should be added termly. (3) The performance of pump shall be degraded with the increase of the clearance between the impeller and fender, so adjust the impeller forward in time for keeping the pump running in high efficiency. If the friction is serious, the spare parts shall be changes. Check the spare partstermly and estimate the useful life of spare parts in case cause serious consequence due to the failure of spare parts. 3 Termination of pumping Before termination of pumping, make the pump draw out a certain clean water for removing the slurry, then close the pump valve shaft gland water and cold water in bearing body in turn.

6 Care and maintenance In order to make the pump run safe with long useful life, must carry out daily maintenance. When carry out maintenance, the following aspects shall be paid attention: 1 Maintenance for shaft gland: Check the water pressure and quantity of shaft gland, keep a certain clan water to flow through the shaft all the time, check the packing gland termly as well as packing. If the packing is not enough, change it. Besides, the water pressure and quantity of shaft gland shall be in accordance with the above requirements. For the pump equipped with mechanical sealing, the mechanical sealing parts shall be added with N45 engine oil in case rusty of this part and aging of inner rubber. 2 Adjusting for impeller: In order to keep high efficiency running, adjust the clearance between the impeller and front fender in time. Before adjust the clearance, must stop the pump, then loosen the bolts for compressing the bearing assembly, and screw the nut of adjusting bolt to make the bearing assembly forward, at the same time, rotate the pump shaft manually as the rotation direction of pump till there is friction between the impeller and front fender. Then loosen the nuts which were screwed down just by half circle, then screw down the nuts in front of the adjusting bolts for making the bearing assembly move backwards, here, the clearance between the impeller and front fender shall be kept at the range 0.5-1mm. after adjustment, recheck the impeller rotation to see if it is in normal condition and is the holding down bolts have been screwed down before restarted. 3 Lubrication of bearing When assemble the bearing assembling, the useful life shall be longer if the assembly is correct and added with proper lubrication oil as well as proper maintenance, in the processing of running, the pump shall be added changed with lubrication oil, the time interval and injection quantity shall be related with the rev bearing spec continuous duty, on and off times and so on, and so the operator should accumulate the 4 operation experience, add to oil reasonably and in time. 4 The stand by pump shall be rotated by 1/4 circle so that the bearing can bear the static load and external vibration evenly. 7 Overall dimension

泵 型 号 泵脚底轴端泵 pump Pump bottom Shaft tip a b f h1 h2 L1 L2 L3 L4 L5 L6 H3 S d L GMZ-10-15 2 120 6 250+0.5 300 127 208 308 348 300 3 25 18 Φ 110 GMZ50-15-15 264 1 641 250+0.5 333 127 208 308 348 300 3 25 18 Φ 110 GMZ50-- 255 120 639 250+0.5 333 127 208 308 348 300 3 25 18 Φ 110 GMZ50-- 264 1 641 250+0.5 333 127 208 308 348 300 3 25 18 Φ 110 GMZ65-15- 311 190 546 245 370 127 135 175 265 3 0 18 Φ35 70 GMZ65-20- 311 1 546 245 3 127.5 135 175 265 3 0 18 Φ35 70 GMZ65-20- 311 1 546 245 3 127.5 135 175 265 3 0 18 Φ35 70 GMZ65-30-70 311 190 546 245 370 127 135 175 265 3 0 18 Φ35 70 GMZ65-30- 311 190 546 245 370 127 135 175 265 3 0 18 Φ35 70 GMZ-20-110 311 1 546 245 3 127.5 135 175 265 3 0 18 Φ35 70 GMZ-50-120 342.5 236.5 870.5 350+0.5 554 154 2 410 4 0 450 30 22 Φ 1 GMZ100-18-170 420 216 891.5 350+0.5 543 154 2 410 4 0 450 30 22 Φ 1 GMZ100-24-120 342.5 236.5 870.5 350+0.5 554 154 2 410 4 0 450 30 22 Φ 1 GMZ100-25-200 420 216 891.5 350+0.5 543 154 2 410 4 0 450 30 22 Φ 1 GMZ100-27-1 420 207 884.5 350+0.5 5 154 2 410 4 0 450 30 22 Φ 1 GMZ100-30- 330 237 864.5 350+0.5 550 154 2 410 4 0 450 30 22 Φ 1 GMZ100-30-1 420 207 884.5 350+0.5 5 154 2 410 4 0 450 30 22 Φ 1

GMZ series Slurry Pump GMZ100-30-200 420 216 891.5 350+0.5 543 154 2 410 4 0 450 30 22 Φ 1 GMZ100-35-250 420 216 891.5 350+0.5 543 154 2 410 4 0 450 30 22 Φ 1 GMZ100--50 342.5 236.5 870.5 350+0.5 554 154 2 410 4 0 450 30 22 Φ 1 GMZ100--200 342.5 236.5 870.5 350+0.5 554 154 2 410 4 0 450 30 22 Φ 1 GMZ100-52- 342.5 236.5 870.5 350+0.5 554 154 2 410 4 0 450 30 22 Φ 1 GMZ100-- 342.5 236.5 870.5 350+0.5 554 154 2 410 4 0 450 30 22 Φ 1 GMZ100--200 414 290 1096.5 450+0.5 630 165.5 370 530 5 500 550 35 22 Φ70 1 GMZ100-70-1 414 290 1096.5 450+0.5 630 165.5 370 530 5 500 550 35 22 Φ70 1 GMZ100--200 414 290 1096.5 450+0.5 630 165.5 370 530 5 500 550 35 22 Φ70 1 GMZ100-95-250 415 305 1212 5+0.5 645 185 430 6 700 620 6 45 32 Φ90 170 GMZ100-1-120 533 320 1222 5+0.5 700 185 430 6 700 620 6 45 32 Φ90 170 GMZ150-25-500 441.5 3 1248 5+0.5 650 185 430 6 700 620 6 45 32 Φ90 170 GMZ150-30-320 370 2 1107 450+0.5 530 165.5 370 530 5 500 550 35 22 Φ70 1 GMZ150-32-0 441.5 3 1248 5+0.5 650 185 430 6 700 620 6 45 32 Φ90 170 GMZ150--300 421 2 1102 450+0.5 570 165.5 370 530 5 500 550 35 22 Φ70 1 GMZ150-45-500 441.5 3 1248 5+0.5 650 185 430 6 700 620 6 45 32 Φ90 170 GMZ150-47-2 5 350 1138.5 450+0.5 750 165.5 370 530 5 500 550 35 22 Φ70 1 GMZ150-58-320 5 350 1138.5 450+0.5 750 165.5 370 530 5 500 550 35 22 Φ70 1 GMZ150--450 441.5 3 1248 5+0.5 650 185 430 6 700 620 6 45 32 Φ90 170 GMZ150-75-350 5 410 1256 5+0.5 0 185 430 6 700 620 6 45 32 Φ90 170 GMZ150-85-530 5 410 1397.5 6+0.5 796 227.5 4 730 790 670 730 50 32 Φ100 210 GMZ150-90-0 559 294 1230 5+0.5 6 185 430 6 700 620 6 45 32 Φ90 170 GMZ150-100-300 615 450 1243.5 5+0.5 1030 185 430 6 700 620 6 45 32 Φ90 170 GMZ150-120-390 5 355 1391.5 6+0.5 750 227.5 4 730 790 670 730 50 32 Φ100 210 GMZ200-70-550 690 390 1241.5 5+0.5 0 185 430 6 700 620 6 45 32 Φ90 170 GMZ200-70-850 500 410 1411.5 6+0.5 5 227.5 4 730 790 670 730 50 32 Φ100 210 GMZ250-14-0 444 330 1125 450+0.5 0 165.5 370 530 5 500 550 35 22 Φ70 1 GMZ250-32-1220 662.5 325 1282 5+0.5 720 185 430 6 700 620 6 45 32 Φ90 170 GMZ250-55-1100 7 4 1420.5 6+0.5 8 227.5 4 730 790 670 730 50 32 Φ100 210 GMZ250-110-1100 7 4 1420.5 6+0.5 8 227.5 4 730 790 670 730 50 32 Φ100 210 GMZ300-22-2100 570 0 1430.5 6+0.5 8 227.5 4 730 790 670 730 50 32 Φ100 210 GMZ300-25-10 570 0 1430.5 6+0.5 8 227.5 4 730 790 670 730 50 32 Φ100 210

Installation Drawing of Directly-Coupled GMZ Slurry pumps(common Base) 型 号 L L1 L2 L3 L4 L5 L6 L7 f a b c H H1 H2 h1 h2 B1 B2 B3 B4 h-d GMZ-10-15 1285 832 478 210 127 154 3 641 2 120 4 670 515 370 250+0.5 300 450 486 3 376 4-Φ19 GMZ50-15-15 1289 832 478 210 127 154 3 641 264 1 4 703 515 370 250+0.5 333 450 486 3 376 4-Φ19 GMZ50-- 1668 1127.5 6 209 127 154 770 639 255 120 4 703 645 370 250+0.5 333 490 526 4-Φ19 GMZ50-- 1679 1127.5 6 209 127 154 770 641 264 1 4 703 645 370 250+0.5 333 490 526 4-Φ19 GMZ65-15- 1505 968 630 185 127.5 1 645 546 311 190 3 720 595 3 245 3 3 410 4-Φ22 GMZ65-20- 1505 968 630 185 127.5 1 645 546 311 1 3 720 595 3 245 3 3 410 4-Φ22 GMZ65-20- 1634 1054 636 210 127.5 154 670 546 311 1 3 720 620 370 245 3 3 410 4-Φ22 GMZ65-30-70 1634 1054 636 210 127.5 154 670 546 311 190 3 7 620 370 245 370 3 410 4-Φ22 GMZ65-30- 1634 1054 636 210 127.5 154 670 546 311 190 3 7 620 370 245 370 3 410 4-Φ22

GMZ-20-110 1634 1054 636 210 127.5 154 670 546 311 1 3 720 620 370 245 3 3 410 4-Φ22 GMZ-50-120 2032 1259 8 245 154 205 815 870.5 342.5 236.5 4 1059 5 505 350+0.5 554 410 4 4-Φ24 GMZ100-18-170 2085.5 1203 758 245 154 205 770 891.5 420 216 4 1048 775 505 350+0.5 543 410 4 4-Φ24 GMZ100-24-120 2057 1259 8 245 154 205 8 870.5 342.5 236.5 4 1059 5 505 350+0.5 554 410 4 4-Φ24 GMZ100-25-200 2085.5 1203 758 245 154 205 770 891.5 420 216 4 1048 775 505 350+0.5 543 410 4 4-Φ24 GMZ100-27-1 2018.5 1163 735 245 154 205 710 884.5 420 207 4 1045 750 505 350+0.5 5 410 4 4-Φ24 GMZ100-30- 1968.5 1203 758 245 154 205 770 864.5 330 237 4 1055 775 505 350+0.5 550 410 4 4-Φ24 GMZ100-30-1 2078.5 1203 758 245 154 205 770 884.5 420 207 4 1045 775 505 350+0.5 5 410 4 4-Φ24 Type L L1 L2 L3 L4 L5 L6 L7 f a b c H H1 H2 h1 h2 B1 B2 B3 B4 h-d GMZ100-30-200 2130.5 1259 8 245 154 205 815 891.5 420 216 4 1048 5 505 350+0.5 542 410 4 4-Φ24 GMZ100-35-250 22.5 1328 8 245 154 205 925 891.5 420 216 4 1048 795 505 350+0.5 543 410 1 4-Φ24 GMZ100--50 1927 1163 735 245 154 205 710 870.5 342.5 236.5 4 1059 750 505 350+0.5 554 410 4 4-Φ24 GMZ100--200 2142 1328 8 245 154 205 925 870.5 342.5 236.5 4 1059 5 505 350+0.5 554 410 4 4-Φ24 GMZ100-52- 2057 1259 8 245 154 205 8 870.5 342.5 236.5 4 1059 5 505 350+0.5 554 410 4 4-Φ24 GMZ100-- 2057 1259 8 245 154 205 8 870.5 342.5 236.5 4 1059 5 505 350+0.5 554 410 4 4-Φ24 GMZ100--200 2565.5 1598 975 315 165.5 265 1050 1096.5 414 290 5 12 1010 650 450+0.5 630 490 550 4-Φ26 GMZ100-70-1 2700.5 1719 1050 315 165.5 265 1185 1096.5 414 290 5 12 1105 650 450+0.5 630 650 710 4-Φ26 GMZ100--200 2700.5 1719 1050 315 165.5 265 1185 1096.5 414 290 5 12 1105 650 450+0.5 630 650 710 4-Φ26 GMZ100-95-250 2973 1894 0 0 355 185 320 13 1212 415 305 6 14 1250 795 5+0.5 645 620 6 6-Φ33 GMZ100-1-120 3286 2000 6 6 3 185 320 1525 1222 533 320 6 1495 1425 795 5+0.5 700 775 8 6-Φ33 GMZ150-25-500 2745.5 1739 650 650 250 185 450 1050 1248 441.5 3 6 1450 11 0 5+0.5 650 620 6 6-Φ33 GMZ150-30-320 2667 1719 1050 315 165.5 265 1185 1107 370 2 5 11 1105 650 450+0.5 530 650 710 4-Φ26 GMZ150-32-0 28.5 1792 0 0 335 185 320 1185 1248 441.5 3 6 1445 1250 795 5+0.5 650 620 6 6-Φ33 GMZ150--300 2768 1719 1050 315 165.5 265 12 1102 421 2 5 1220 1105 650 450+0.5 570 650 710 4-Φ26 GMZ150-45-500 3220.5 2000 6 6 3 185 320 1525 1248 441.5 3 6 1445 1425 795 5+0.5 650 775 8 6-Φ33 GMZ150-47-2 2963.5 1719 1053 315 165.5 265 13 1138.5 5 350 5 1395 1100 645 450+0.5 750 635 690 4-Φ26 Type L L1 L2 L3 L4 L5 L6 L7 f a b c H H1 H2 h1 h2 B1 B2 B3 B4 h-d GMZ150-58-320 3063.5 1785 0 0 315 165.5 265 13 1138.5 5 350 5 1395 1100 645 450+0.5 750 635 690 6-Φ26 GMZ150--450 3220.5 2000 6 6 3 185 320 1525 1248 441.5 3 6 1445 1425 795 5+0.5 650 775 8 6-Φ33 GMZ150-75-350 3367 2000 6 6 3 185 320 1525 1256 5 410 6 1595 1425 795 5+0.5 0 775 8 6-Φ33 GMZ150-85-530 34.5 2824.5 1000 1000 412 227.5 358 2025 1397.5 5 410 7 1656 1445 8 6+0.5 796 859 920 6-Φ33 GMZ150-90-0 3320 2000 6 6 3 185 320 1525 1230 59 294 6 1475 1425 795 5+0.5 6 775 8 6-Φ33 GMZ150-100-300 3389.5 2691 1000 1056 3 185 320 2025 1243.5 615 451 6 1830 1845 0 581+0.5 1030 875 9 6-Φ33 GMZ150-120-390 3843.5 2689.5 924 924 420 227.5 350 1865 1391.5 5 355 7 1610 1225 8 6+0.5 750 815 876 6-Φ33

GMZ200-70-550 3462.5 20001 6 6 3 185 320 1525 1241.5 690 390 6 1595 1425 795 5+0.5 0 775 8 6-Φ33 GMZ200-70-850 3943.5 2824.5 1000 1000 412 227.5 358 2025 1411.5 500 410 7 1665 1445 8 6+0.5 5 859 920 6-Φ33 GMZ250-14-0 2759 1719 1050 315 165.5 265 1185 1125 444 330 5 1250 1105 650 450+0.5 0 650 710 4-Φ26 GMZ250-32-1220 3975.5 2691 1000 1056 3 185 320 2025 1282 662.5 325 6 1520 1845 0 5+0.5 720 875 9 6-Φ33 GMZ250-55-1100 4269.5 3019.5 1022 1022 4 227.5 290 2235 1420.5 7 4 7 17 1645 8 6+0.5 8 959 1020 6-Φ33 GMZ250-110-1100 4454.5 3289.5 11 11 4 227.5 290 2420 1420.5 7 4 7 17 1895 8 6+0.5 8 1097 11 6-Φ33 GMZ300-22-2100 4242.5 3019.5 1022 1022 4 227.5 290 2235 1430.5 570 0 7 1700 1645 8 6+0.5 8 959 1020 6-Φ33 GMZ300-25-10 32.5 2824.5 1000 1000 412 227.5 358 2025 1430.5 570 0 7 1700 1445 8 6+0.5 8 859 920 6-Φ33 8 Common faults and removal method Common faults Possible cause Removal method No suction Air leakage in suction pipe or packing position Incorrect rotation direction and the impeller has Block up the part with air leakage Check the rotation direction and change the

been broken Blockage in suction pipe impeller Remove the blockage Larger power consumption for shaft Overheating in bearing Short useful life for bearing Serious leakage in packing position Too tightened for packing gland and high temperature in packing Friction in pump Damage to bearing Too tightened belt of driving device Larger flow rate Higher rev and larger proportion No centration and parallelism between the motor shaft and pump shaft. Excessive or less lubrication oil in bearing Sundries in lubrication oil Damage to bearing No centration and parallelism between the motor shaft and pump shaft. Bending for shaft Friction in pump or loss of balance for impeller Foreign body in bearing or Unreasonable assembly for bearing Serious wearing in packing Serious wearing in shaft liner Not clean for sealing water Loosen the bolt of packing gland Remove the friction Change the bearing Adjust the belt Adjust the running state of pump Adjust the rev Adjust the motor and pump shaft Addtoproperlubricationoil Change the lubrication oil Change the bearing Adjust the motor and pump shaft Change the shaft Remove the friction and change the impeller Clean the bearing Change the bearing or reassemble the bearing Change the packing Change the shaft liner Change the sealing water Cute vibration and larger noise Damage to bearing Imbalance for impeller Blockage for suction pipe Uneven flow rate and pumpout in pump Change the bearing Change the impeller Remove the air input and clean the blockage position Change the feeding of pump 9 Flow passage components

Pump Cover Volute Impeller 1 Impeller 2