Phase Sequence Tester

Similar documents
User's Manual. Earth Ground Resistance Tester. Model Introduction

User's Guide. Vane Anemometer. Model Measures Air Velocity & Temperature. Degrees C/F switchable

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Introduction

User Guide. Model Insulation Tester / Megohmmeter. Introduction

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

Model Battery Powered Milliohm Meter

Panel Mount Digital Tachometer Model

User's Guide. EzFlex Thermo-Anemometer. Model EZ30 UNITS MAX MIN AVG VEL

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

Users Manual. Phase Rotation Indicator

User's Manual. Model Hot Wire Thermo-Anemometer. Introduction

User's Guide. CO 2 Meter. Model CO250

User's Guide. True RMS Multim eter. Extech 430

Non-Contact Phase Rotation Tester

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

Non-Contact Phase Rotation Tester

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

Dawson DDM190D. Digital Multimeter User s Manual

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

362 Clamp Meter. Users Manual

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

302+/303 Clamp Meter. Users Manual

362 Clamp Meter. Users Manual

373 Clamp Meter. Users Manual

USER MANUAL. Insulation Tester + DMM. Model MG320

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

i400s Calibration Information Introduction

DIGITAL INSULATION RESISTANCE TESTER (5KV, 1T )

365 Detachable Jaw True-rms Clamp Meter

Tracer ORP PockeTester TM Code 1742

323/324/325 Clamp Meter

Instruction Manual IVT-10 / IVT-20 Voltage Tester

AMB V Insulation Resistance Tester. Users Manual. For detailed specifications and ordering info go to

PD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL

Model Insulation Tester / Megohmmeter. User Manual

Users Manual. MegOhmMeter

KMP Insulation-Continuity Tester. Users Manual

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Megohmmeter Test Probe

DIGITAL RCD(ELCB) TESTER

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

Dawson DAN100. Analog Multimeter User s Manual

Calibration Manual. Detachable Jaw True-rms Clamp Meter

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

233 True-rms Remote Display Digital Multimeter Safety Information

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING

USER GUIDE Moisture Meter

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings


The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

User Guide. Model Insulation Tester / Megohmmeter

User Guide. Model Insulation Tester / Megohmmeter

PTC8001 Temperature Calibrator

Rental Industry Safety Tester Safe Check 5s

INSTRUCTION MANUAL DM5B Fax: (503)

KSZ 10B Current Probe Calibrator. Instruction Manual

Visit us at

Go to to register your product and find more information.

719 Series. Pressure Calibrator with Electric Pump. Product Overview (E)


USER GUIDE. Model RH10 Hygro Thermometer. Humidity and Temperature Meter

Temperature Calibrator

PY-11 Voltage & Continuity Tester

Manual Supplement. For IEC V, CAT I & 600, CAT II Meters only. Serial NO and greater.

User s Manual. Item no. 2561

KSZ 100B Current Probe Calibrator. Instruction Manual

Bio-Pump Plus. Operating Instructions. Product # ZBP-200. Description. Specifications

Instruction Manual ICM A1 AC/DC Clamp Meter ICM A1

Cable Length Meter INSTRUCTION MANUAL

717 Series. Pressure Calibrators. Instruction Sheet. Introduction

BK BK A BK MA BK MA BK J93 MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

HIGH VOLTAGE DIGITAL AMMETER

For technical questions and replacement parts, please call

A Member of the. Integrated Metering Technologies

1 AMP CURRENT SOURCE

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

DT304. Digital Temperature Logger INSTRUCTION MANUAL

THERMOCOUPLE CALIBRATOR Mode KM-CAL-710

OPERATING INSTRUCTION

UNDERGROUND CABLE TESTER

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

KMP7010. Ground Resistance Tester. Users Manual

INSP-3 Wiring Inspection Tester

TESTER SET SOCKET & VOLTAGE

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

3.5mm Coaxial Calibration Kit

A Member of the. Integrated Metering Technologies

Installation Guide. Marine Filter SURT023M SURT024M

INSTRUCTION MANUAL SURFACE RESISTIVITY METER SRM-110

Table of Contents Title Page No.

18VDC ESB6 Series Cordless Screwdrivers Operation Manual

OPERATING INSTRUCTION

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Tank Monitor. Instruction manual DTM01. Tank Monitor

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

Transcription:

User's Guide Phase Sequence Tester Model 8000

Introduction Congratulations on your purchase of the Extech Model 0800 Phase Sequence Tester. This handheld instrument detects the phase sequence of three-phase systems. Color-coded test leads are provided for connecting to the three mains phases of the system under test. This meter is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Safety International Safety Symbols! Caution! Refer to the explanation in this Manual Caution! Risk of electric shock Earth (Ground) Double Insulation or Reinforced insulation AC, Alternating Current or Voltage DC, Direct Current or Voltage Safety Procedures To avoid possible electric shock or fire, observe the following: Read the following information carefully before using or servicing the instrument. Adhere to local and national safety codes. Individual protective equipment must be used to prevent shock and injury. Use of instrument in a manner not specified by the manufacturer may impair safety features/protection provided by the equipment. Avoid working alone.

Inspect the test leads for damaged insulation or exposed metal. Check test lead continuity. Damaged leads must be replaced. Do not use the phase Rotation indicator if it appears damaged. Use care when working above 0V ac rms, V ac peak and 60V dc. Such voltages pose a shock hazard. When using the probes, keep fingers away from probe contacts. Keep fingers behind the finger guards on the probes. Measurements can be adversely affected by impedances of additional operating circuits connected in parallel or by transient currents. Verify operation prior to measuring hazardous voltages (voltages above 0V ac rms, V ac peak and 60V dc). Do not use the phase Rotation indicator with any of the parts removed. Do not use the phase Rotation indicator around explosive gas, vapor, or dust. Do not use the meter in a wet environment. Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a six month limited warranty applies to sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at (781) 890-70 ext. 10 for authorization or visit our website www.extech.com for contact information. A Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied.

Description Meter Description 1. Test Lead alligator clips. Test lead input jacks. L1, L, L display icons. Clockwise Rotation LCD Indicator R (right) and L (left) icons. Sequence grid Display Description 1. Line designators (L1, L, and L). Color codes for test leads. Clockwise / Counter-Clockwise indicator. LEFT (L) or RIGHT (R) rotation direction. Phase Sequence grid 1 1 1

Operation Determine Phase Rotation Direction 1. Connect the supplied color-coded test leads to the meter s test lead input jacks at the top of the meter.. Connect the test probes to the three mains phases for the system under test.. L1, L, and L indicators will illuminate one at a time on the meter s LCD display as each phase is connected.. The clockwise and counter-clockwise arrows with the left/right L or R icons display the phase rotation direction of the device under test.. The sequence grid simply shows the three line sequences for Clockwise R and the three line sequences for Counter-Clockwise L. Note: The rotational arrow indicators illuminate even if one of the test probes is connected to a neutral or ground conductor instead of one of the mains phases.

Specifications Nominal Voltage 0 to 690 VAC Frequency Range (fn) 1 to 00HZ Current pickup 1 ma Nominal Test current (in per phase) 1 ma Maximum Operating Voltage (Ume) 690 V Operating Temperature to 10 o F (0 to 0 o C) Type of protection IP 0 Dimensions (H x W x D):.1 x.7 x 1. (10 x 69 x mm) Weight.6 oz. (10g) Approvals CE (EU directives) Safety For indoor use and in accordance with the requirements for double insulation to IEC1010-1 (199): EN61010-1 (199) Overvoltage Category III 600V and Category IV 00V, Pollution Degree. Calibration and Repair Services Extech offers repair and calibration services for the products we sell. Extech also provides NIST certification for most products. Call the Customer Care Department for information on calibration services available for this product. Extech recommends that annual calibrations be performed to verify meter performance and accuracy. Support line (781) 890-70 Technical Support: Extension 00; E-mail: support@extech.com Repair & Returns: Extension 10; E-mail: repair@extech.com Product specifications subject to change without notice For the latest version of this User Guide, Software updates, and other up-to-the-minute product information, visit our website: www.extech.com Extech Instruments Corporation, 8 Bear Hill Road, Waltham, MA 01 Copyright 007 Extech Instruments Corporation All rights reserved including the right of reproduction in whole or in part in any form. 6