MANUAL Free Form Plastic Products freeformplastics.com

Similar documents
MT2000 HYDRAULIC SWATH ROLLER COMMON HYDRAULIC ASSEMBLY INSTRUCTIONS Kit Part No

MT2000 HYDRAULIC SWATH ROLLER MODEL - MACDON M150/M200 SERIES & JOHN DEERE W150

OWNER S MANUAL. Model: TR-40-GAS ( ) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly) Technical Specifications

Pressure Roller with 24-inch Fixed Extension - For application of architectural paints and coatings -

Operator and Parts Manual

Bertolini Sprayer Operator s Manual

OPERATING MANUAL 18V Ni-Cd Battery Pack

RECYCOIL Used Oil Tank

GARDEN HOSE UTILITY PUMP

Operator s Safety and Service Manual

Model No. LG55-3PT 55 Gallon Sprayer 3 Point Lawn & Garden Sprayer Model No. LG27-3PT 25 Gallon Sprayer GENERAL INFORMATION

gamma uv Aquarium Ultraviolet Sterilizers

ROTARY BRUSH CUTTERS THE LEADER OF THE PACK OWNER/OPERATOR SAFETY & INSTRUCTION MANUAL

EMISSION CONTROL WARRANTY STATEMENT

AUTOMATIC SUBMERSIBLE UTILITY PUMP

Transmission Guardian

Kit INSTALLATION GUIDE. For maximum effectiveness and safety, please read these instructions completely before proceeding with installation.

Operations and Parts Manual

MODEL NO. UTL Gallon 12 Volt Skid Mounted Utility Sprayer ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

OWNER S MANUAL. Model 9214 HIGH OUTPUT 12 VOLT TRANSFER PUMP /06 10/17

PPM EO-100 TM. Operation Manual

FALKEN TIRE LIMITED WARRANTY

DIRECT-DRIVE PRESSURE WASHERS

PRO STEER Block Hydraulic Installation. New Holland TR Series Combine Harvester

-HART. Packer Systems 30 Series

LG-60-3PT-WP-309-BL-TSC

Specialty Pond Sprayer

1200W INVERTER GENERATOR

Cleanload Chemical Eductor

Power Float Manifold. Installation and Operations Manual Module 11A

OWNER S MANUAL. Model: PLATINUM55 ( ) (55 Gallon Deluxe Lawn & Garden Spot Sprayer)

MODEL NO. UTL-60-7

-HART. Packer Systems 20 Series

K -HART. Coulter. Owner s Manual Model 1600, 1620, 1601, 1602, 1603

1416 Cabinet Unit. Installation Operation Maintenance Troubleshooting Version Dec/17

Installation Instructions

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

OWNER S MANUAL. Model: LG-30-TRL ( ) (30 Gallon Lawn & Garden Trailer Sprayer)

Where to Find Us. Pressure Washer. Model Number Revision Serial Number. Date Purchased

SUBMERSIBLE SUMP PUMPS

Warranty Statement. Global Commercial Warranty Statement. Commercial Generating Set Transfer Switch Switch Gear. A028U870 (Issue 1)

THANK YOU FOR CHOOSING ATOM ELECTRIC.

US Patent 0540, 400 Other Patents Pending. Read this manual completely before assembling and riding our PET PRO-FLEX 500. Always wear a Helmet!

SILVAN AUSTRALIA PTY. LTD.

12V Oil Extractor Pump

MGFHVLP. Instructions/Parts. Mini Gravity Feed System E. Part No Includes MGFHVLP Mini Gravity Feed Spray Gun and MGC 125 Gravity Cup.

StormPro BA Series Sump Pump

Pro Shot Grease Dispense Valve

KING CANADA 950W PORTABLE GENERATOR MODEL: KCG-951G INSTRUCTION MANUAL COPYRIGHT 2011 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC.

stroller kit Burley Stroller Kit Owner s Instruction and Safety Manual For D Lite, Solo, Encore, Cub, Honeybee, and Tailwagon

Installation Procedures Ford F150 2X4, 4X4, Flex Fuel & Eco boost SNS 42

Operator and Parts Manual. Hammermill FK354

Texture Gun & Hopper

Trailer Sprayer Owner s Manual

HPx-JDx3-xx HARNESS INSTALLATION

Installation Instructions

STOP. LP-50DEF-BRL Lever Hand Pump System Barrel Mounting. Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS

Model GD-K77D4X-XX Supplement to the GD-K77D Operator s Manual

MODEL NO. TSSK GALLON SKID-MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

Penguin Gentoo 600B Cordless Sprayer User s Manual

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

Model: ATVTS-60-12V 60 Gallon Trailer Sprayer W/7 Nozzle Boom ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

Installation Instructions

OWNER S MANUAL Model: TR-40-EX ( ) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly)

WETech Active Trimmer

Spray Nozzle Adapters

c EDR /11. ShipShape OWNERS MANUAL. [ power foundations ]

Model:M5B/M5W/M5N. Installation Guide. Specifications Desktop Weight Capacity Keyboard Tray Weight Capacity Height Adjustable Range

Table of Contents. Technical Information Warning Statement

OWNER S MANUAL. Model: GOLD25 ( ) (25 Gallon Lawn & Garden Spot Sprayer)

Installation Procedures Camaro 1LE & Factory Installed Spoiler SNS 89a

Installation Instructions

Auto-tilt Solar LED Umbrella

SHOP PRO FXP 95 TECHNICAL MANUAL

16 Inch Surface Cleaner

MODEL NO. SK-61-12V 12 VOLT SKID MOUNTED LAWN & GARDEN SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

720W PORTABLE GENERATOR

Owner's Manual LGX5P Sprayer

Pressure Washer Hose Reel

Operator s Manual. Automatic Electric Jack Leveling. The leveling system shall only be operated under the following conditions:

MOTORCYCLE / ATV 2010 Distributor s Warranty

Installation Instructions

TBE-700. Operation, Safety and Maintenance Manual. Stainless Steel Weld Cleaning System. Ensitech Pty Ltd

Offset Solar LED Umbrella

BRAKE ASSIST SYSTEM INSERT SHEET

SUNC3000 / Item #40885

AC/DC Powered Peak Detection Fast Charger for 4- to 8-Cell Ni-Cd & Ni-MH Batteries

Garden Hose Reel with 3/4In. x 100Ft. Hose. Owner s Manual

Operator and Parts Manual. Power Mover

Versa Stainless Wash System

COOL DRAFT INSTRUCTIONS OWNER S MANUAL CONTENTS. Cool Draft MiniMister 14 Misting Fan CDMP1420BLU

Rechargeable Inflator

Installation Procedures Shelby GT500 Super Snake SNS 13a

Installation Procedures Dodge Challenger Hellcat (Upper Mount) SNS 1e

OWNER S MANUAL 40 LAWN AERATOR SAT-40 BH. Assembly Installation Operation Repair Parts. Visit us on the web! MODEL:

Owner s Manual Instructions for Assembly and Operation

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

Model: SK-61-4R 60 Gallon Skid Mounted Sprayer ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

Owner's Manual. Model: SK-61-4R ( ) (60 Gallon Skid Sprayer w/2.5 H.P. Engine, 4-Roller Pump, Deluxe Handgun) Technical Specifications

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

Transcription:

MANUAL Free Form Plastic Products Box 159, 100 Bourgault Drive St. Brieux, Sask. S0K 3V0 306-275-2155 306-275-2101 sales@freeformplastics.com freeformplastics.com

CONTENTS FREE FORM WARRANTY POLICY... 3 SAFETY... 5 INITIAL STARTUP... 5 CHEMBINE FUNCTIONS... 6 HOW TO USE THE KNIFE BLOCK AND RINSE... 7 OPERATION... 8 SOLID CHEMICAL MIX... 9 JUG CHEMICAL MIX... 10 TOTE CHEMICAL MIX... 11 CHEMICAL INDUCTION MIX... 12 POSITIONS... 13 WINTERIZE... 17 Figure 1 - Bypass Valve Open... 13 Figure 2 - Bypass Valve Closed... 13 Figure 3 - Inductor Source Selection Tote... 14 Figure 4 - Inductor Source Selection Chembine... 14 Figure 5 - Pump Source Selection Tank... 15 Figure 6 - Pump Source Selection Off... 15 Figure 7 - Pump Source Selection Chembine... 16 2

FREE FORM WARRANTY POLICY Free Form Plastic Products (referred to as Free Form), a Division of Bourgault Industries Ltd., warrants its new, unused, Agricultural Equipment to be free of defects in material and workmanship at time of the delivery to the first retail purchaser according to the Free Form Warranty Policy. 1) BASIC WARRANTY REPAIR PERIOD AND REMEDIES a) Free Form will repair or replace, at its option, without charge for parts or labour, any defective part of the equipment for a period of twelve (12) months from delivery to the first retail purchaser. b) Free Form will repair or replace, at its option, without charge for parts, any Free Form manufactured part that is found to be defective for the period of thirteen (13) months to twenty-four (24) months from delivery to the first retail purchaser. c) Free Form will repair or replace, at its option, for a charge of 50% of the parts, any Free Form manufactured part that is found to be defective for the period of twenty-five (25) months to thirty-six (36) months from delivery to the first retail purchaser. Note: A Free Form Manufactured Part is any part which has been manufactured by Free Form. Parts purchased from an outside supplier are not considered to be manufactured by Free Form. Purchased parts would include bearings, bolts, etc... d) Any parts that are covered by an Extended Warranty published by Free Form, are an exception to the Basic Policy, and are to be warranted as per the details of the Extended Warranty document. The extended warranty policy may change from time to time without warning from Free Form. 3 2) EXCEPTIONS TO THIS WARRANTY a) In no event shall the owner be entitled to recover for incidental, special or consequential damages such as, but not limited to; loss of crop, loss of profit or revenue, other commercial losses, inconvenience or cost of rental of replacement equipment. b) Repair, Maintenance, and Service items not related to defects: i. Loss or damage during shipment (see: Free Form Whole goods Shipping Policy) ii. Failure resulting from lack of or improper maintenance. iii. Damage caused by operator abuse, negligence, or improper operation. iv. Non-defective items replaced due to customer demand unless authorized by Free Form. v. No reimbursable maintenance items including but not limited to oil, etc. vi. Any and all costs for repairs or replacement of parts not shown to be defective. vii. Damage due to accidents. c) Pump and fittings are not covered under this warranty policy, but by the warranty policy of their manufacturer. e) Replacement Parts will be warranted for twelve months from the repair date, providing the bill of sale is attached to the warranty claim. f) The terms of this warranty are subject to Provincial and State Legislation. Free Form reserves the right to make changes in accordance with these Acts at any time without notification or obligation. The stated warranty contained in the Free Form Warranty Policy applies in all situations, unless the law provides a greater

warranty in the jurisdiction of the retail customer. g) Free Form reserves the right to continually improve its equipment, and reserves the right to change products or specifications at any time without notice or obligation. 3) OWNER S OBLIGATION It is the responsibility of the owner, at the owner s expense, to transport the equipment to the service shop of an authorized Free Form Dealer (place of purchase) or alternately to reimburse the dealer for any travel or transportation expense involved in fulfilling this warranty. It is the responsibility of the owner to read, understand and practice the maintenance, safety, and operational guidelines set out in the operator s manual furnished with the equipment. It is the owner s responsibility to ensure that the Warranty Registration, which must be signed by the owner, is completed and returned to Free Form by the dealer. The completed and signed Warranty Registration is required to register a new unit for warranty. 4

SAFETY Safety is extremely important when working with dangerous chemicals and devices. The safety factor CANNOT be overstressed. For your safety, or that of others who you may have operating your Chembine, it is important that anyone working on or around the machine realizes the inherent dangers presented by the nature of the work the machine does. Toxic chemicals, flammable liquids, sharp edges, pressurized fittings and hoses all pose hazards. The lack of safety could cause serious bodily injury or death, therefore the Chembine should never be used by someone who is not familiar with this manual or the chemicals they are using. 1. Familiarize yourself with the possible dangers of the chemicals. 2. Be sure no one comes near the Chembine when operating, especially children. 3. Always wear proper personal protective equipment as recommended by the chemical suppliers. 4. Take care when refueling the pump to prevent fires. A hot engine can cause a fire and extreme caution should be taken when dealing with one. 5. Always be mindful of fittings under pressure and avoid dead heading the system. INITIAL STARTUP Before you start up the Chembine for the first time ensure the engine oil and coolant for the wet seal are topped up. Oil: 10W30 (0.63 qt.) Coolant: 50/50 Antifreeze (0.75 qt.) Fuel: 86 Octane minimum (0.95 gal.) 5

1 2 3 13 12 11 4 10 5 6 7 8 9 CHEMBINE FUNCTIONS 1- Rotary Rinse Valve: Open to activate tank rinsing function. 2- Vortex Agitation Valve: Open to activate vortex mixing agitation. 3- Bulkhead Agitation Valve: Open to activate bulkhead cleaning agitation. 4- Garden Hose Valve: Open for water when washing down equipment. 5- Pump Source Selection: Use to select the pump source. 6- Pump Bottom Drain: Open to drain the pump out complete. 7- Chembine Bottom Drain: Open to drain the Chembine out complete. 8- Inductor Source Selection: Selects inductor source between the main tank and an optional tote. 9- Tote Connection Valve: Open to allow flow from tote. 10- Cut Off Valve: Open to allow flow to the sprayer. 11- Fresh Water Valve: Open to allow fresh water source for cleanup. 12- Bypass Valve: Close to allow for flow through the inductor system. 13- Jug Rinse Valve: Open to activate the jug rinse. 6

HOW TO USE THE KNIFE BLOCK AND RINSE Ensure to note the orientation of the jug handle and the leading edge of the knife point shown above. Lift the jug over the knife point, and then force the jug downwards. The Jug will bottom out on the frame of the knife block. Once the Jug has drained rinse by using the Jug Rinse Valve. ALWAYS be aware of the sharp edges of the knife block when working with the CHEMBINE. ALWAYS ensure you are familiar with all the safety requirements of the chemicals you are working with. 7

OPERATION The Chembine can mix a variety of chemicals including solid materials alongside the typical liquid found in jugs and totes. Below is the standard process for operating the unit. Pay special care to the order of operations shown in brackets if required; this is important so as to avoid dead heading the pump. When operating the Vortex Agitation Valve ensure that the eductor is fully submerged in order to prevent splashing from the tank. The operations shown in this manual are based on the Free Form Plastics recommended setup utilizing a three way valve on the inlet of a wet seal pump to allow for recirculation ability. If you desire to illuminate the recirculation ability use the provided cap and elbow spare parts to close off the plumbing. Deviating from the standard setup will affect the operation processes shown in this manual. For these setups the operation guides on the following pages will provide a general basis for operation, but may need revising for your specific needs. 8

SOLID CHEMICAL MIX Use this provided method for mixing solid chemicals through recirculation and agitation. 1. With the ignition pump off, pump source selection valve off, inductor source set to Chembine, bypass valve open, and all other valves closed you are in the starting position. 2. Set the pump source selection to draw from the tank position, and then start the pump. The Chembine will begin to fill. 3. When the Chembine s tank has filled to at least 25 IMP GAL change the pump source selection valve to draw from the Chembine. Immediately open the vortex agitation, and bulkhead agitation valve. The Chembine will begin to recirculate and mix. 4. Add chemical to the mixture as per your needs then employ the inductor by opening the cut off valve, closing the bypass valve, and setting the pump source selection to tank. 5. Once the chemical is inducted and you wish to rinse out the tank open the rotary rinse valve to begin rinsing. Close the bulkhead and vortex agitation valves. The Chembine will still be inducting the rinse into the sprayer. 6. Once the Chembine s tank is clean, close the rotary rinse valve and wait for the last wash to induct. Once complete open the bypass valve and the Chembine will begin to fill the sprayer at maximum flow. 7. When the sprayer is full set the pump source selection to off, throttle down the pump, and then close the cut off valve. SOLID CHEMICAL MIX PUMP SOURCE SELECTION INDUCTOR SOURCE SELECTION BYPASS CUT OFF VORTEX AGITATION BULKHEAD AGITATION ROTARY RINSE JUG RINSE as needed TOTE FRESH WATER Starting Point OFF CB O X X X X X X X Start Pump TANK CB O X X X X X X X Recirculate (25 IMP GAL MIN) CB(1) CB O X O O X X X X Induction TANK(3) CB X(2) O(1) O O X X X X Chembine Rinse TANK CB X O X X O X X X Fill Sprayer TANK CB O(2) O X X X(1) X X X Complete OFF(1) CB O X(2) X X X X X X 9

JUG CHEMICAL MIX Use this provided method for inducting chemical when using jugs. 1. With the ignition pump off, pump source selection valve off, inductor source set to Chembine, bypass valve open, and all other valves closed you are in the starting position. 2. Working from right to left, open the cut off valve, close the bypass valve, set the pump source selection to the tank providing fresh water. Start the pump and the sprayer will begin filling slowly while drawing through the inductor. 3. Begin breaking jugs and rinsing as needed by operating the jug rinse valve. 4. When you are done adding chemical open the rotary rinse valve to clean out the Chembine s tank. The wash will induct into the sprayer. 5. Once the Chembine s tank is clean, close the rotary rinse valve and wait for the last wash to induct. Once complete open the bypass valve and the Chembine will begin to fill the sprayer at maximum flow. 6. Once the sprayer is full set the pump source selection to off, throttle down the pump, and then close the cut off valve. JUG CHEMICAL MIX PUMP SOURCE SELECTION INDUCTOR SOURCE SELECTION BYPASS CUT OFF VORTEX AGITATION BULKHEAD AGITATION ROTARY RINSE JUG RINSE as needed TOTE FRESH WATER Starting Point OFF CB O X X X X X X X Start Pump TANK(3) CB X(2) O(1) X X X X X X Break Jug and Rinse TANK CB X O X X X O X X Chembine Rinse TANK CB X O X X O X X X Fill Sprayer TANK CB O(2) O X X X(1) X X X Complete OFF(1) CB O X(2) X X X X X X 10

TOTE CHEMICAL MIX Use this provided method for inducting chemical when using totes. 1. With the ignition pump off, pump source selection valve off, inductor source set to Chembine, bypass valve open, and all other valves closed you are in the starting position. 2. Working from right to left, open the cut off valve, close the bypass valve, set the pump source selection to the tank providing fresh water. Set the inductor source selection to tote and open tote valve. Start the pump and the sprayer will begin filling slowly while drawing through the inductor. 3. Chemical from the tote will flow through the inductor to the sprayer. 4. When you are done adding chemical to the sprayer connect the fresh water valve to the tote connection valve in order to clean out the remaining chemical in the line. 5. Once the Chembine s tote line is clean, close the tote connection valve and open the bypass valve. The Chembine will begin to fill the sprayer at maximum flow. 6. Once the sprayer is full set the pump source selection to off, throttle down the pump, and then close the cut off valve. TOTE CHEMICAL MIX PUMP SOURCE SELECTION INDUCTOR SOURCE SELECTION BYPASS CUT OFF VORTEX AGITATION BULKHEAD AGITATION ROTARY RINSE JUG RINSE as needed TOTE FRESH WATER Starting Point OFF CB O X X X X X X X Start Pump TANK(3) TOTE X(2) O(1) X X X X O X Induction TANK TOTE X O X X X X O X Flush line TANK TOTE X O X X X X O O(1) Fill Sprayer TANK TOTE O(3) O X X X X X(2) X(1) Complete OFF(1) TOTE O X(3) X X X X X X 11

CHEMICAL INDUCTION MIX Use this provided method for mixing solid chemicals through agitation and induction. 1. With the ignition pump off, pump source selection valve off, inductor source set to Chembine, bypass valve open, and all other valves closed you are in the starting position. 2. Set the pump source selection to draw from the tank position, and then start the pump. The Chembine will begin to fill. 3. With at least 25 IMP GAL in the Chembine tank open the vortex agitation valve, and bulkhead agitation valve. Then immediately open the cut off valve and close the bypass valve. The Chembine will begin to simultaneously mix chemical in the tank while inducting. 4. Once the chemical is inducted and you wish to rinse out the tank open the rotary rinse valve to begin rinsing. Immediately close the bulkhead and vortex agitation valves. The Chembine will still be inducting the rinse into the sprayer. 5. Once the Chembine s tank is clean, close the rotary rinse valve and wait for the last wash to induct. Once complete open the bypass valve and the Chembine will begin to fill the sprayer at maximum flow. 6. When the sprayer is full set the pump source selection to off, throttle down the pump, and then close the cut off valve. LIQUID CHEMICAL INDUCTION MIX PUMP SOURCE SELECTION INDUCTOR SOURCE SELECTION BYPASS CUT OFF VORTEX AGITATION BULKHEAD AGITATION ROTARY RINSE JUG RINSE as needed TOTE FRESH WATER Starting Point OFF CB O X X X X X X X Start Pump & Fill to 25 IMP GAL TANK CB O X X X X X X X Induction TANK CB X(3) O(2) O(1) O(2) X X X X Chembine Rinse TANK CB X O X X O X X X Fill Sprayer TANK CB O(2) O X X X(1) X X X Complete OFF(1) CB O X(2) X X X X X X 12

POSITIONS Figure 1 - Bypass Valve Open Figure 2 - Bypass Valve Closed 13

Figure 3 - Inductor Source Selection Tote Figure 4 - Inductor Source Selection Chembine 14

Figure 5 - Pump Source Selection Tank Figure 6 - Pump Source Selection Off 15

Figure 7 - Pump Source Selection Chembine 16

WINTERIZE Preparing the Chembine for winter is a simple and easy process. Once the bulk of the liquid is removed through conventional means you are ready to begin the process below; Be sure that any possible low points in lines are not holding any excess water. 1. Open the pump bottom drain and the chembine bottom drain valve. Be sure to collect and dispose of the drained chemical as per the suppliers recommendations. 2. Close the two micro valves. 3. Pour antifreeze directly into the tank. 4. Open all the valves except the two bottom drain valves holding the antifreeze in partially. This will prevent any possible issues from residual moisture that may remain. 17

PRINTED IN CANADA