PART NO: FD2460-C0151E2AL CUSTOMER APPROVAL

CUSTOMER: MODEL NO: 4020II (CeraDyna Fan) NO: FD2440-C0151D2AL. DATE : September 3, 2007 CUSTOMER APPROVAL

PART NO: FD1212-A2251G2AL. DATE : June 9, 2010 CUSTOMER APPROVAL

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

CUSTOMER: MODEL NO: 4020III (CeraDyna Fan) PART NO: FD1240-A0241D0AL DATE: CUSTOMER APPROVAL. Taiwan. Approved QC Checked Checked Prepared

CUSTOMER: ARCERA EU MODEL NO: 5115 (CeraDyna Fan) PART NO: FW2451-A1051C2AL DATE: CUSTOMER APPROVAL. Taiwan

Rated load current (resistive load) SRP. Min. 0.9 (max. 25 of difference between voltage phase and current phase)

CUSTOMER: PART NO: FD1212-A1051E2AL. DATE : January CUSTOMER APPROVAL. Taiwan. Mainland China(F1)

Model Number Structure

Immersion Pumps PS and PSL ( Slurp Pump ) sealless

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 120X120X25 mm M O D E L : KD2412PTB1-6A

EPS/ELA-Series User Manual EPS/ELA 250W

TF037C MICRO BLOWERS FEATURES STANDARD SPECIFICATIONS

Model Number Structure

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Model Number Structure

Technical Data, High Power 2-way* Cannon APD / ISO Connectors. Electrical Data. Mechanical Data. Environmental Data (acc.

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 92X92X25 mm M O D E L : KD1209PTB1 P/N : (2).H

L1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel

AC centrifugal fan. backward curved

韩国 Autonics 进口固态继电器型号模拟固态继电器 SRPH1 SRPH1 Series SSR 比例控制继电器选型说明书 pdf Single phase, Analog input type SSR Features Power control/ Cycle control/phase c

Centrifugal pumps. Main catalogue.

FBA08A (80 X 25.5 L )

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 40X40X10 mm M O D E L : KD1204PFS2-8

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

18091-PS. Preliminary General Specification PSM (AC) PES REV: PAGE. 1 of 8

Ionizer (Nozzle type) Series IZN10

AC centrifugal module - RadiCal

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

MOONS SM servo motors offer a great combination of Power, Precision and Value:

Brake Pack SB50W. Standard AC Motors A-143. Standard AC Motors Intro duction. Brake Pack. AC Speed Control Motors Inverter.

AC axial fan. blades with special design (K series) with guard grille for full nozzle

AC Fans. AC Fans Overview 117. AC Axial Fans 118. AC Radial Fans 138. Technology. DC Axial Fans. DC Radial Fans. Specials. ACmaxx Axial Fans.

Rotary Sensor potentiometric Heavy-duty. Series IPX-7900

General_technical_data Series

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS BLOWER. DIMENSIONS : 45X45X9 mm M O D E L : GB0545AFV1-8

INDUSTRIAL THERMAL MANAGEMENT. Filter fans FL-Series

General Specifications. Cooling Method 3M series are IC 411 Standard. IC 416, IC 418 can be provided Upon request

55185 EMERGENCY PACK FOR LED PANEL TECHNICAL DATA SHEET

Technical Documentation Regenerative Turbine Pump with Canned Motor Y-2951-W-MM

1SVC F SVC F 0607 R100.20/30 R100.45

Information. DC axial fans. DC axial fans. DC axial fan overview 27 DC axial fan / DC diagonal fan

Technical Documentation Radial Pump with Canned Motor Y-1638-MM

AC axial fan. sickled blades (S series) with full square nozzle

Specification of Soneil Battery Charger

Technical Documentation Radial Pump with Canned Motor MY-3-MM

Thermal Overcurrent Circuit Breaker 3130

Specification of Soneil Battery Charger

AC axial fan. straight blades (A series) with full round nozzle

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Thermal Overcurrent Circuit Breaker 3130

General_technical_data Series

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

LED Driver Linear / area dimming

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

MB Series AC Centrifugal Blowers

Magnetic and Hydraulic-Magnetic Circuit Breaker

AC centrifugal fan. backward curved

3-Phase Military AC-DC Power Supply 3-Phase, VrmsL-L

Input voltage Power rating Output voltage Output current With Front mounting Bracket. With DIN-rail mounting Bracket 400/480 VAC

Energy-saving motors (ESM)

Thermal Overcurrent Circuit Breaker 3130

Input terminals Isolation method Zero cross function Operation indicator Alarm output Applicable load (See note.) Model

CUSTOMER: 12038III (CeraDyna Fan) DATE : April 23, 2007 CUSTOMER APPROVAL

Thermal Circuit Breaker 3120-F...

Model Number Structure

Knürr CoolBlast. Top-Mounting Fan for Miracel

Safety Standards. Model Number:

Specification of Soneil Battery Charger MODEL: 5807SR 60V5A BATTERY CHARGER

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Thermal Overcurrent Circuit Breaker 3120-F...

Scheda prodotto Relè Series B

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

Thermal Overcurrent Circuit Breaker 3120-F...

LMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma

2 to 25 A, 100 to 240 VAC G3PF-225B-STB Compact slotted

Efficiency Model dependant 86 ~ 88% Isolation. Isolation Cap. Switching Freq. Safety. Case Material Base Material Potting.

5-Phase Stepper Motor

2: A, B 3: A, B, Z 4: A, A _, B, B _ 6: A, A _, B, B _, Z, Z _

Transcription:

The engineer's choice

4414/2H INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical Operating Data... 5 3.3 Operating Data - Electrical Interface -Output... 6 3.4 Electrical Features... 7 3.5 Aerodynamic... 8 3.6 Sound Data... 9 4 Environment... 9 4.1 General... 9 4.2 Climatic requirements*)... 9 5 Safety... 10 5.1 Electrical Safety... 10 5.2 Approval Tests... 10 6 Reliability... 10 6.1 General... 10 5/7/2012 page 2 of 10

1 General Fan type Rotational direction looking at rotor Airflow direction Bearing system Mounting position Fan clockwise Air outlet over struts Ball bearing any 2 Mechanics 2.1 General Width Height Depth Weight Housing material Impeller material Max. torque when mounted across both mounting flanges Screw size 119,0 mm 119,0 mm 38,0 mm 0,270 kg Plastic Plastic wire outlet corner: 80 Ncm remaining corners: 80 Ncm ISO 4762 - M4 degreased, without an additional brace and without washer 2.2 Connections Electrical connection Length of lead wire Tolerance Wires 310 mm Wire gauge (AWG) 24 Insulation diameter 1,10 mm +- 10,0 mm Colour Operation Wire 1 red + UB Wire 2 blue - GND Wire 3 white Tacho The auxilliaries shown on the schematic diagram (which are required for the intended use) are not part of our delivery. 5/7/2012 page 3 of 10

3 Operating Data 3.1 Operating Data - Electrical Interface - Input Control input 5/7/2012 page 4 of 10

3.2 Electrical Operating Data Measurement conditions: Normal air density = 1,2 kg/m3; Temperature 23 C +/- 3 C; Motor axis horizontal;warm-up time before measuring 5 minutes (unless otherwise specified).in the intake and outlet area should not be any solid obstruction within 0,5 m. p = 0: corresp. to free air flow (see section 3.5) I: corresp. to arithm. mean current value Features Condition Symbol Values Voltage range p = 0 U 18,0 V 28,0 V Nominal voltage p = 0 U N 24,0 V Power consumption p = 0 4,4 W 8,6 W 11,3 W Tolerance P +- 17,5 % +- 12,5 % +- 15,0 % 0001 Current consumption p = 0 245 ma 360 ma 405 ma Tolerance I +- 17,5 % +- 12,5 % +- 15,0 % 0001 Speed p = 0 3.490 1/min 4.300 1/min 4.850 1/min Tolerance n +- 12,5 % +- 7,5 % +- 10,0 % 0001 Starting current consumption < 1.400 ma 5/7/2012 page 5 of 10

3.3 Operating Data - Electrical Interface -Output Tacho type /2 (Open collector) Features Note Values Tacho operating voltage (UBS) <= 30 V Tacho signal Low I sink: 2 ma <= 0,5 V Tacho signal High I source: 0 ma Maximum sink current <= 4 ma External resistor External resistor Ra from UBS to US required. All voltages measured to GND. Tacho frequency (2 x n) / 60 Tacho isolated from motor No Alarm type 5/7/2012 page 6 of 10

3.4 Electrical Features Electronic function Reversed polarity protection Max. residual current at Un Locked rotor protection Locked rotor current at Un Clock signal t3/t4 at locked rotor Rectifying diode IF < 100 ua Auto restart approx. 1.400 ma Typical: 0,6 s / 10,0 s 5/7/2012 page 7 of 10

3.5 Aerodynamic Measurement conditions: Measured with a double chamber intake rig acc. to DIN EN ISO 5801. Normal air density = 1,2 kg/m3; Temperature 23 C +/- 3 C; In the intake and outlet area should not be any solid obstruction within 0,5 m. a.) Operation condition: 4.300 1/min at free air flow Max. free-air flow ( p = 0 / = max.) 240,0 m3/h Max. static pressure ( p = max. / =0) 160 Pa 5/7/2012 page 8 of 10

3.6 Sound Data Measurement conditions: Sound pressure level: 1 Meter distance between microphone and the air intake. Sound power level: Acc. to DIN 45635 part 38 (ISO 10302) Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 db(a) For further measurement conditions see section 3.5 a.) Operation condition: 4.300 1/min at free air flow Optimal operating point Sound power level at the optimal operating point Sound pressure level at free air flow, measured in rubber bands 148,0 m3/h @ 60 Pa 6,0 bel(a) 50,0 db(a) 4 Environment 4.1 General Min. permitted ambient temperature TU min. -20 C Max. permitted ambient temperature TU max. 70 C Min. permitted storage temperature TL min. -40 C Max. permitted storage temperature TL max. 80 C 4.2 Climatic requirements*) Humidity requirements humid heat, constant; according to DIN EN 60068-2- 78, 14 days Water exposure Radiation exposure Dust requirements Salt fog requirements Harmful gas requirements *) Permittet application area: The product is intended for use in sheltered rooms with controlled temperature and controlled humidity. Directly exposure to water must be avoided. Pollution degree 1 (according DIN EN 60664-1) There is either no pollution or it occurs only dry, non-conductive pollution. The pollution has no negative impact. 5/7/2012 page 9 of 10

5 Safety 5.1 Electrical Safety Dielectric strength DIN EN 60950 (VDE 0805) and DIN EN 60335 (VDE 0700) A.) Type test Measuring conditions: After 48h of storage at 95% R.H. and 25 C. No arcing or breakdown is allowed! All connections together to ground. B.) Routine test Measuring conditions: At indoor climate. No arcing or breakdown is allowed! All connections together to ground. Isolation resistance Measuring conditions: After 48h of storage at 95% R.H. and 25 C measured with U=500 VDC for 1 min. Air and leakage distances Protection class 500 VAC / 1 Min. 500 VAC / 1 Sec. RI > 10 MOhm 1,0 mm / 1,2 mm III 5.2 Approval Tests CE UL VDE CSA CCC Yes Yes / UL audited by CSA according to UL507, Electric Fans Yes / Approval acc. to EN 60950 (VDE 0805) - Information technology equipment Yes / C22.2 No. 113 Fans and Ventilators No The approval tests are observed to: U approval max.:28,0 V @ TU approval max.: 70,0 C 6 Reliability 6.1 General Life expectancy L10 at TU = 40 C Life expectancy L10 at TU max. Life expectancy L10 Delta (40 C) 57.500 h 27.500 h 110.000 h 5/7/2012 page 10 of 10