The JR Linear Drive System

Similar documents
The JR Linear Drive System

Actuators & Positioners Pneumatic Actuators Series UP1/2/3/4/5/6

Models UP1/2/3/4/5/6/7 Universal pneumatic rotary actuators. Measurement made easy. High performance actuators for precision damper control

Actuators & Positioners Models UP1/2/3/4/5/6/7. Universal Pneumatic Rotary Actuators

12 Series Linear Actuators. Operation & Maintenance Manual, Analog Positioner Installation

COMPLETE LISTING OF OPTIONS. Toggles, Lights

Flowrite Globe. Pneumatic 4-inch Valve Actuator. Valves. Description. Applications. Features D-141.

Electric Modulating Actuator Installation, Operation & Maintenance Manual

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Electric Actuator Options & Accessories

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

RUS-L24-MOD Electric 24 Volt Modulating Control Damper & Louver Actuator

Double Acting & Spring Return. SERIES 92/93 Rack & Pinion PNEUMATIC ACTUATOR. The High Performance Company

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

MT SERIES PNEUMATIC ROTARY ACTUATORS

Designed for ease of integration with automation systems

Type Type 1001 Transducers. I/P & E/P Transducers

MODEL 422 Submersible Pump Controller

Dissolved Oxygen Measurement System with Air Blast Cleaner

Actuated Valves PRICING

Miniature I/P, E/P Transducer for Electronic Air Pressure Control


Rotary + Linear Damper Drives

Miniature I/P, E/P Transducer for Electronic Air Pressure Control

DMC mA Positioner

Electric Actuator Accessories. Timer Board 115 VAC Input Suffix A (For EVR, EVS & EVT actuators)

Fisher 480 Series Yokeless Piston Actuators

12 Series Linear Electric Actuator Installation, Operation & Maintenance Manual

GE Energy. The Becker * DNGP: Fail-Safe Protection for Your Gas Pipeline

Damper Actuator Installation

Technical Specification. RCS Electric Actuators with a ProfiBus Field Control and Communication Module

Electric Actuated Ball Valves 150# Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe

Double and Single Acting Pneumatic Quarter-turn Actuators with Flexible Valve and Accessory Mounting

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners.

IPB-CM An ISO 9001 company ELECTRIC ACTUATORS FOR INDUSTRIAL PROCESS CONTROL CEMENT & LIME PLANTS. BECK VIDEO Scan w/ Smartphone 1

Z-Tech Severe Chemical Service Valves We Put Control Where You Need It.

PISTON STYLE GAUGE. Mid-West Instrument

ABB Automation. Characterizable Pneumatic Positioners Series AV1/2/3/4. Series AV1/2/3/4 Pneumatic Positioners

CP-9301 CP Application. Features. Applicable Literature. Electronic Actuator Drives General Instructions

SM-1000 SERIES ROTARY ACTUATORS

PISTON STYLE GAUGE. For Installation and Operation Manuals Please Visit: Mid-West Instrument

Series Electric Actuators

CLARK SOLUTIONS 8E Series Electric Actuated NEMA 4X Ball Valves 1/4 to 4 Brass & Stainless Steel, 2-way & 3-way configurations

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

POSITION TRANSMITTERS

ELECTRIC ACTUATOR HVAC/BAC ELECTRIC IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

ELECTRIC ACTUATOR 94OE IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

11280A HercuLine Series Actuator. Specification. Non-Contact Position Sensing and Variable Speed Motor Control. Overview. Features. Actuator Operation

M9216 Series Electric Spring Return Actuators

T-1001 TYPE 1001 I/P & E/P TRANSDUCERS

Electric Actuated Ball Valves 3-piece Stainless Steel, Full Port 1/4 to 3 NPT

OpenAir Electronic Damper Actuators GLB Series Enhanced Non-spring Return Rotary

FasTrak High Capacity Smart Positioner

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control

Electric Actuator Instructions

RUS-L24-MOD Electric 24 Volt Modulating Control Damper Actuator

IPB-MI ELECTRIC ACTUATORS FOR INDUSTRIAL PROCESS CONTROL MINING AND MINERAL INDUSTRIES

SRX Series Stainless Steel Body Air Cylinders with Continuous Position Feedback

Control Valves Positioner

Control Valves Positioner

Table of Contents General Specifications, Available Mountings... 1 Introduction... 2 Application Examples... 3 Features... 4 Theory of Operation... 5

Low Profile Insertion Vortex

TECHNICAL BULLETIN. Logix 510si Series Digital Positioner. Experience In Motion FCD LGENTB /09

VA-640GSX024P. Overview. Applications. Features & Benefits. Datasheet. Large Globe Valve Actuators

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control

Spring Cylinder Rotary Actuator

SPECIFICATIONS ATTENTION OPERATION DESCRIPTION

Fisher 657 and 667 Diaphragm Actuators

Full 316SS design Up to 70,000Nm in DA! High Temp ** Low Temp ** No Painting or ENP coating required ISO mounting NAMUR VDI/VDE

Powers Controls No. 4 Pneumatic Damper Actuator

MEMFlo MFTV METAL BODIED FLOW METER WITH CLEAR TOP

Customized ELECTRO-HYDRAULIC CONTROL SYSTEM

Electric Actuators Maximum in-lbs

QB4 PRESSURE CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 124

ELECTRIC ACTUATORS. Series 70 Pgs 4-11 PRODUCT QUALITY & PRECISION INTRODUCTION

Electric Actuators Maximum in-lbs

PEAKTRONICS DMC-101 ADDITIONAL FEATURES. DC Motor Controller, 5A DMC-101

Powers TM Controls EA 338 Electronic Actuator

MP-5400 Series. Application. Features. Applicable Literature. Electronic Positive Positioning Hydraulic Actuator General Instructions

E Series Electric Actuators

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

Position Transmitters. Instruction Manual. Established Leaders in Valve Actuation. Electric Actuators and Control Systems

Accutrol, LLC Product Sheet AVC5000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

Minimum 27 in-lb torque

See «Overview of types»

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry. Precision Airflow Measurement An ONICON Brand

3D TRASAR Automation - Boiler Blowdown Equipment

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 123

Installation and Operating Manual

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return Rotary 24 Vac 3-position Control

Signet Temperature Transmitter

SERIES PA PNEUMATIC CYLINDERS FOR VALVE ACTUATION BORE SIZE: 3 1/4 TO 20 RATING: 150 PSIG (1000 KPA)

CLARK SOLUTIONS 8P Series Pneumatic Actuated Ball Valves 1/4 to 4 Brass & Stainless Steel, 2-way & 3-way configurations

Product Specifications - SCN Helical and Helical Bevel Gear Series. Accessories...36 Terms of Sale...46 NOTE WARNING

A Compact and Reliable Quarter-Turn Electric Actuator

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

BOILER BLOWDOWN CONDUCTIVITY CONTROLLER (CONTINUOUS METHOD)

Transcription:

D A M P E R D R I V E S TM The JR Linear Drive System Technical Data Sheet TDS JR-1000 ROTARY + LINEAR DAMPER DRIVES

TABLE OF CONTENTS SECTION PAGE NUMBER 1. Introduction 3 2. Applications 3 3. Features and Benefits 4-5 4. Operation 6 JR Power Cylinders 6 DPC-777 6-10 5. Specifications 10 JR Power Cylinders 10 DPC-777 11 6. Drawings 12 Basic JR Power Cylinders 12 JR Power Cylinders (Comparisons to existing electric drives) 13-14 DPC-777 15 7. Ordering Information 16 Standard JR Ordering Code Sheet 16 TDS JR -1000 2 version: 01.27.09

1. INTRODUCTION The JR Linear Drive System is a high-performance, digital controlled, pneumatically operated linear damper drive system suitable for most wall-fired boilers. JR Linear Drives are specifically designed to replace existing electrically operated linear drives. Take-out dimensions were selected to make the JR drive a quick and easy retrofit solution for most conventional electric linear drives. Unlike most pneumatically operated drives, the JR incorporates all the fail-in-place characteristics of electric drives without the drawbacks of limited duty cycles and low resistance to moderate ambient temperatures found in most utility power boiler applications. 2. APPLICATIONS The JR drive is specifically designed to control the position of the air dampers that modulate the amount of secondary air to a pulverized coal burner as shown in the illustration below. Most wall-fired boilers typically have burners where the fuel and combustion air are combined. In pulverized coal fired boilers the fuel is conveyed by the primary air. Primary air flow is determined by the pulverizer. Secondary air is introduced at the burner and its flow is determined by a sliding disk or sliding sleeve mechanism that is usually positioned by a linear actuator. Most linear actuators in use today are operated by an electric motor that drives a lead screw type mechanism. In past times these electrically operated drives were typically placed in one of three positions; light-off, full-load, and idle/cooling by setting hardto-adjust travel switches. Frequent modulation of the electric drives usually resulted in premature failure due to limited duty cycle design. With the JR Linear Drive System, users are free to modulate the drive position as often as required to maintain set point conditions and are not limited to a few pre-settable travel stop locations. TDS JR -1000 3 version: 01.27.09

3. FEATURES AND BENEFITS The JR Linear Drive System has many advanced features that will enhance the operation of any air damper, and reduce or eliminate frequent and costly maintenance while improving overall performance. Unlimited Duty Cycle Which means the JR drive can be operated as frequently as necessary without fear of component failure or motor burn-out? High Temperature Construction The JR drive with its 300ºF rated Power Cylinder is designed for long-life in the high ambient temperatures typically found around utility boilers. This will lower the overall cost-of ownership and increase up-time. Very-High Performance Positioning The Power Cylinder is capable of being positioned to within +/- 0.5% which means better and more repeatable damper positioning to aid in overall operation and to help lower NOx. Split-Architecture Design All control components may be located up to 100 feet away from the Power Cylinder and boiler front allowing for easier access while placing all electronics in a more favorable environment. Local / Remote Selector Switch This feature allows for complete drive operation from the firing asile. Fewer Moving Parts Fewer moving parts and no Deadband Robbing gears and couplings means less maintenance and much improved positioning performance Completely Field Repairable All major components are modular and can be easily repaired or replaced without having to send the drive back to the factory, and in most cases without having to remove the drive to a service area. This results in lowering the cost of ownership and increasing uptime The JR Linear Drive System improves overall performance, is easy to install and set-up, and simple to maintain because of the thoughtful design approach, simplicity of construction, and careful selection of all components. TDS JR -1000 4 version: 01.27.09

The JR Linear Drive System consists of two principal components. The JR Linear Power Cylinder with a self-contained patented Linear Position Transducer. The DPC-777 Digital Position Controller The JR Linear Power Cylinder Actuator The JR linear cylinder actuator is a highly engineered linear air cylinder designed to provide high performance and extended life in the harsh environments found in and around the burners on wall-fired utility boilers. Materials of construction have been selected to resist the corrosion and abrasion from long-term exposure to coal dust and fly ash, and to provide long life JR Linear Power Cylinders are available in sizes and thrust ratings to meet every Secondary Air application. Piston Size Piston Strokes Developed Thrust @ 100 psig 4 in. dia. 6 in, 12 in, & 18 in. 1178 lbs. 5 in. dia. 6 in, 12 in, & 18 in 1885 lbs. Note: Refer to page 00 for envelope dimensions for all Power Cylinders. The DPC-777 Digital Position Controller The DPC-777 Digital Position Controller The Type K DPC-777 is a high-performance digital damper drive position controller that has many advanced features that will improve the operation of any damper control system. The enclosure is non-metallic, NEMA 4X design. TDS JR -1000 5 version: 01.27.09

4. OPERATION OPERATION OF THE JR POWER CYLINDER BASIC POWER CYLINDER AND LINEAR POSITION TRANSDUCER ARRANGEMENT The anodized extruded aluminum cylinder with hard chrome plated piston rod is available in 4 inch and 5 inch diameter piston sizes and 6 inch, 12 inch, and 18 inch stroke lengths. Standard seals are BUNA-N, High Temp (300ºF) seals are Viton. The unique Twin-seal rod gland assembly prevents fly ash and coal dust from entering the cylinder. The linear position transducer (LPT) is mounted within the cylinder and connected to the DPC-777 controller enclosure by a 3-conductor cable. The cylinder can be located up to 100 ft. from the DPC-777 controller. The cylinder can be configured to extend or retract on an increasing 4-20 ma signal to the DPC-777. THE DPC-777 DIGITAL POSITION CONTROLLER The DPC-777 Digital Position Controller consists of five principal components. The Digital Control Module (DCM) The digital/pneumatic interface module (4-way 3-position proportional valve), installed inside the remote mounted control enclosure. Assorted switches terminal strip, bulkhead fittings (air connections), and glands (electrical connections). Either 25 ft / or 100 ft of shielded 3-wire connecting cable w/ quick disconnect connector at the Power Cylinder end. NEMA 4X Fiberglass enclosure rated 20 to +120 º F* All components are readily accessible and easily maintained by the user. Note: Optional enclosure materials of construction are available, consult the factory TDS JR -1000 6 version: 01.27.09

The DPC-777 Digital Position Controller The principal component of the Digital Position Controller is the Digital Control Module (DCM). All operations, with the exception of setting the stroke speed are performed on the DCM by manipulating the (3) push buttons. No additional calibration equipment is necessary. DPC-777 Enclosure Door Push Buttons The door of the DPC-777 is equipped as standard with a RESET push button. The purpose of this push button it to interrupt to line power to the DPC-777 to allow the resetting of the digital control module should a fault occur. As an optional feature the DPC-777 may be furnished with two selector switches marked REMOTE / LOCAL and CLOSE / OPEN. These switches allow for the complete operation of the JR Linear Drive in the field location. Placing the REMOTE / LOCAL switch in the local position interrupts the 4-20 ma input signal from the process control system and permits operation of the CLOSE / OPEN selector. Holding the CLOSE / OPEN selector in either the close or open position will cause the drive to respond accordingly. When pressure is removed from the CLOSE / OPEN selector switch it will return to the center off position. Digital Control Module (DCM) Operational Push Buttons TDS JR -1000 7 version: 01.27.09

OVERVIEW OF DCM The simple three-button control on the digital circuit module is used to configure all parameters the unit needs for a wide variety of applications, and allows the open and closed positions to be easily set for direct or reverse operation without any re-wiring. The input signal is 4-20 ma DC. Various option modules are available and are easily plugged into the unit, providing for position feedback and travel/alarm switches. 4-20 ma loop powered, isolated position feedback signal 4-20 ma device powered, non-isolated position feedback signal with (2) two adjustable position relay contacts, and (1) fault relay contact. All relay contacts are rated 0.5 A @ 120 VAC, 1.0 A @ 24 VDC. Operational Features Position control to +/- 0.5% or better on the Type K JR Linear Drive. Adaptive Control continuously adjusts for load and actuator conditions and eliminates calibration procedures and auto-cal operations. Three-button control provides easy setup Polarity detection allows direct or reverse acting operation without rewiring Stall detection can prevent damage to mechanical equipment. Operating temperature range of 32 to 120 F (0 to 50ºC) Fail-in-Place or Fail Open or Closed on loss of signal. Fail-in-Place on loss of air or power supply. All components are easily user maintained in the field. DCM Operation The Digital Control Module (DCM) is designed to operate a proportional valve with up to 5.0 Amp running current. The unit is easily mounted with two screws and is equipped with removable screw terminals that provide for easy field wiring. The simple three-button control (MODE,, and ) allows the user to perform a complete set-up from the unit itself without the need for any instrumentation. The adaptive control feature of the DCM eliminates the need for any calibration steps. In the simplest application, only the open and closed positions need to be set, the DCM automatically and continuously sets all other parameters when placed in the AUTO mode. TDS JR -1000 8 version: 01.27.09

Mode The MODE button is used to select the desired function of operation. When the MODE button is pressed, the unit will switch to the next function and the appropriate LED indicator will turn on to let the user know which function is selected. Each of the modes is described in more detail in the following sections. Adjust Up ( ) and Adjust Down ( ) The Adjust Up ( ) and Adjust Down ( ) buttons are used to adjust the setting of any given function. When a function is selected by the MODE button, adjust buttons will affect that function only. Note, that the AUTO mode does not have any adjustable settings, and therefore, the adjust up ( ) and adjust down ( ) have no effect AUTO The AUTO function is the normal mode of operation for the DCM; all other functions are used to set up the unit. While in AUTO the unit is controlled by the Demand (input) signal. When the unit is not in the AUTO mode, all external controls described below will be disabled. MANUAL / FB POT CAL The MANUAL / FB POT CAL function allows manual operation of the drive by using the adjust buttons ( and ) without affecting any other settings within the DCM. Note: The FB Pot Cal feature is not used when controlling a Power Cylinder. CLOSE The CLOSE function is used to set the desired closed position. When the CLOSE function is selected, the adjust buttons are used to set the drive to the required position, and upon pressing the MODE button (to select the function OPEN), the DCM will retain the setting as the defined closed position OPEN The OPEN function works the same way as the CLOSE function with the exception that the adjust buttons are used to set the desired open position. As with the CLOSE function, on selecting the OPEN function, the drive will move to the previously set open position. AUX CLOSE OUTPUT The AUX CLOSE OUTPUT function is used to set an optional relay output contact closure that is associated with the closed position an optional relay module is required to use this feature. AUX OPEN OUTPUT The AUX OPEN OUTPUT function is used to set an optional relay output contact closure that is associated with the open position an optional relay module is required to use this feature. COMMAND TYPE TDS JR -1000 9 version: 01.27.09

The COMMAND TYPE function is used to configure the Demand (input) signal for 4-20 ma so as to match the type of command signal being used. No other Demand (input) signal types are currently in use. LOSS OF COMMAND When using 4-20 ma, input for the Demand signal, the DCM will detect when the Demand signal is lost or out of range. A loss of command condition is detected whenever the Demand (input) is disconnected, becomes less than 3.0mA, or the Demand (input) signal becomes greater than 22 ma. If the DCM detects a loss of command signal, the Fault indicator will flash and the drive will be moved to one of the three preset positions FAULT / AUX POSITION OUT CAL When the FAULT indicator flashes, a fault condition has been detected The POSITION OUT CAL function is used to calibrate an optional feedback transmitter output. An optional 4-20 ma position feedback module is required to use this feature. FAULT INDICATOR The DCM detects various fault conditions that prohibit the unit from controlling the drive. When any of these conditions are detected, the fault indicator will flash, and the outputs to the Power Cylinder are turned off until all fault conditions are corrected. If an appropriate relay option is installed, the fault relay contact closure will open. Note: Refer to the JR Installation and Operating Manual for a complete description of the DCM operation. 5. Specifications JR Power Cylinder Materials of Construction: Power Cylinder body: extruded aluminum hard anodized for corrosion resistance Power Cylinder piston & endcaps: high strength aluminum alloy Piston rod: hard chrome plated and polished carbon steel Fasteners & Tie-rods: zinc plated steel Rod Seal & Rod Wiper: carboxylated nitrile (Std. Temp), fluorocarbon (high temp) Ratings: Temperature: -20º to150 ºF (std. temp), -20 to 300 ºF (high temp) Pressure: 250 psig max. Mounting Arrangement: Piston and Cylinder end treatments to suit application. LPT Specifications Fluids: Compressed Instrument Air Repeatability: 0.001 (dependent on stroke) Life Expectancy: 500 Million inches travel Max. Stroke: 18 Pressure Rating: 5000 psig Impedance: > 500K ohms Temperature Rating: 300 F Resistance: 1000 ohms/inch +/- 20% TDS JR -1000 10 version: 01.27.09

DPC-777 Digital Controller Specifications Power Requirements DCM-777S: 117VAC +/- 10%, 50/60 Hz, 15VA DCM-777L: 24 VAC +/- 10%, 50/60 Hz. Demand Input Signal Input Impedance: 251 ohms +/- 1% (4-20 ma) Loss of Command threshold: < 3mA or > 22mA (4-20 ma) Feedback Signal Input Input voltage: 0 to 2.5 VDC External LRT: 1K ohm/inch of travel Digital Circuit Module Operating Temperature Range: 32 to 140 F (0 to 60ºC) Storage Temperature Range: -40 to 185ºF (-40 to 85 C) Relative Humidity Range: 0 to 90% (non-condensing) Digital/Pneumatic Interface Module Operating Temperature Range: 32 to 120 F (0 to 60 C) Control Feedback LRT Operating Temperature Range: -40 to +302 F (-40 to 150 C) Enclosure Construction meets NEMA / EEMAC Type 4, 4X Specifications. UL 508 and UL 50 listed, Type 1, 2, 3, 3R, 4, 4R. CSA certified file LR 89590-1. Enclosure flammability rating per UL 508. Joint Industrial Council (JIC) enclosure sizing. TDS JR -1000 11 version: 01.27.09

6. Drawings JR Power Cylinders TDS JR -1000 12 version: 01.27.09

JR Power Cylinder compared to a Jordan LA-2400 Series TDS JR -1000 13 version: 01.27.09

JR Power Cylinder compared to a Jordan LA-2500 Series TDS JR -1000 14 version: 01.27.09

DPC-777 Position Controller TDS JR -1000 15 version: 01.27.09

TYPE K JR Linear Drive JR Ordering Code Sheet Date: REV. Item: Qty: Quote No: Tag: File No: End-User Utility: Customer: Location / Plant: P.O. No: Unit No: End User: Power Cylinder Construction Specifications Digital Position Controller Specifications 1 Bore Diameter inches & Thrust lbs. 7 Position Controller at 100 psig (6.90 bar) air supply pressure D1 DPC-777 Digital Position Controller 4 4 inches (101.6mm), 1178 lbs. (535 kg) w/ "Reset" button. 5 5 inches (127mm), 1885 lbs. (855 kg) D2 DPC-777 Digital Position Controller w/ "Reset" button, "Local/Remote" Available air supply pressure and "Open/Close" switches. psig / psig / bar Max. bar Min. 2 Mounting Arrangement 8 Position Feedback Transmitter / Travel Switches A Front & Rear Clevis Mounting (B & W style Jordan) 4-20 ma direct feedback or 20-4 ma reverse feedback B B & W OEM Special 0 None 2 4-20 madc loop powered, isolated output Replaces: New OEM installation 3 4-20 madc device powered non-isolated, output w/ three (3) SPST relay contacts, (2) Travel Switches & (1) Fault Alarm (dedicated use) Travel switch contact ratings: 3 Stroke, maximum & minimum 0.5 A @ 120 V AC 1.0 A @ 24 V DC A 6 in (152.4 mm) max. / 1.5 in (38.1 mm) min. B 12 in (304.8 mm) max. / 3 in (76.2 mm) min. 9 Power Cylinder to DPC-777 Connecting Cable C 18 in (457.2 mm) max. / 4.5 in (114.3 mm) min. 1 25 ft. (7.62 m) w/ multi-pin connecter/dressed leads 4 Action 2 100 ft. (30.48 m) w/ multi-pin connecter/dressed leads A Extend rod on increasing signal Cable rated for -20 to +300 deg. F. (-28 to + 149 deg. C) B Retract rod on increasing signal 10 Enclosure Rating 1 NEMA 4X, IP66, watertight & dusttight 5 Materials of Construction -20 to +120 deg. F. (-28 to + 49 deg. C) Note: no agency electrical approvals 1 Anodized aluminum with hard chrome-plated steel piston rod. and 304 SS hardware 2 Painted metal NEMA 4, IP66, watertight & dusttight -20 to +120 deg. F. (-28 to + 49 deg. C) Note: no agency electrical approvals 6 Temperature Rating 1-20 to +150 deg. F. (-28 to + 66 deg. C) Notes on the Air Filter Requirements 2-20 to +300 deg. F. (-28 to +149 deg. C) (filters purchased as a separate line item) 1 No filter required buyer assumes liability of failure due to under spec. air quality. Notes Clevis mount, pin to pin length when fully retracted: 2 Combo Particulate & Coalescing Air Filters suggested use is (1) filter package for every (4 to 6) DPC-777s (this feature is required for the 3-year warranty) inches (mm) Type K Dwg. No.: Approx. weight: lbs. (Kg) SELECTED FIGURE NO: JR - Code Item: 1 2 3 4 5 6 7 8 9 10 JROC Rev. 06-24-09 10410 Vista Park Road Dallas, TX 75238 PH: 214/343-9980 FAX: 214/343-2658 Website: www.typek.com

D A M P E R D R I V E S TM www.typek.com ROTARY + LINEAR DAMPER DRIVES Pedestal Mount Direct Drop-In Design matches existing drive Re-use existing link rod and clevis Highly accurate & responsive Simple maintenance-free operation Direct Mount Mounts directly to boiler wall of damper frame No Play connection to damper shaft Highly accurate & responsive Simple maintenancefree operation LX Linear Drive The Ultimate Rod Gland Cleaning System 1.5 to 24 Bore / Any Practical Stroke Exact Retrofit to match existing drive O/C or Modulating Service Valve Automation Automate butterfly, ball and plug valves Simple one-moving part design Retrofit linkage available with drive Complete range of O/C & Modulating controls JR Linear Drive Wall-Fired boiler secondary air control Precise Drop-In replacement for electric drives Precise modulating control Remote-mount digital controller Ash Hopper High-Cycle Ash Hopper solution Replace unreliable diaphragm drums or pistons Totally-enclosed, maintenance-free design Rated for 300 Degrees F CT Series T-Fired boiler Secondary Air Control Trunnion-mount pivot style design For High-Temperature and Harsh Environments Precise Modulating Control Controls S-800 Digital Smart & C-400 Conventional Positioners DPC-777 Remote Mount Digital Positioners Accessories Windbox Bearing Upgrade, air filters 950 Series Loading station, connecting rod linkage Your Representative is: Controls International, Inc. 10410 Vista Park Road Dallas, Texas 75238 Main: (214) 343-9980 Fax: (214) 343-2658 www.cii-holdings.com Our drives are proudly made in Dallas Texas, USA