GETTING STARTED GUIDE NI AI/1 Neutral, 400 Vrms L-N/690 Vrms L-L, 24 Bit, 50 ks/s/ch Simultaneous

Similar documents
GETTING STARTED GUIDE NI AI, ±10 V, 12 Bit, 500 ks/s Aggregate

NI 9251 with mini XLR

GETTING STARTED GUIDE NI AI, ±10 V, 16 Bit, 1 MS/s/ch Simultaneous

GETTING STARTED GUIDE NI Channel Sinking Digital Input Module

GETTING STARTED GUIDE NI AO, ±10 V, 16 Bit, 25 ks/s/ch Simultaneous

GETTING STARTED GUIDE NI DI, ±5 V to 24 V, Differential/Single-Ended, 500 ns

GETTING STARTED GUIDE NI DO, 5 V to 30 V, Sourcing, 1 μs

GETTING STARTED GUIDE NI DO, 6 V to 30 V, Sourcing, 100 μs

GETTING STARTED GUIDE NI AI Differential/32 AI Single-Ended, ±200 mv to ±10 V, 16 Bit, 250 ks/s Aggregate

GETTING STARTED GUIDE NI AI, 51.2 ks/s/ch Simultaneous, Universal Measurements

SAFETY INFORMATION & INSTALLATION GUIDE RMX Programmable Power Supplies. About the RMX Safety Information & Installation Guide

CALIBRATION PROCEDURE NI Channel, ±0.5 V, 24-Bit Simultaneous, Channel-to-Channel Isolated Analog Input Module

Bracket and Assembly Dimensions

NI Pin DSUB to Screw-Terminal Connector Block

Industrial Rack Mount Kit for CompactRIO and CompactDAQ

CALIBRATION PROCEDURE NI Channel, ±10 V, 16-Bit Analog Voltage Output Module

Contents. Software. CALIBRATION PROCEDURE NI PXIe Ch, 24-bit, 25.6 ks/s Universal Bridge Input Module. ni.com/manuals

Shielded Connector Block for the NI PXI/PXIe-2532/2532B

INSTALLATION GUIDE NI WSN-3291 Outdoor IP Enclosure For NI WSN-32xx Series Devices

INSTALLATION GUIDE NI 9921/9922 Outdoor IP Enclosure For NI WLS-9000 Series Devices

NI TB Introduction INSTALLATION INSTRUCTIONS. Terminal Block for the NI PXI/PXIe-2527

NI PS-15/16/17 Side Mount Brackets

SCXI Power Supply/Float Charger Installation Guide

UZK12.261, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 26AH 1/10.

UZK24.071, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS

Electrical Installation

362 Clamp Meter. Users Manual

Safety and General Information

Megohmmeter Test Probe

Operating Instructions

- Wiring Brochure Mixing Expansion Module 440

Solenoid Operator 0516 / 1216

F5 Platforms: FIPS Kit Installation MAN

365 Detachable Jaw True-rms Clamp Meter

373 Clamp Meter. Users Manual

PF 3100 ION PILOT CARD PRO.FIRE

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

i3000s/i2000 Flex AC Current Probe

Solenoid coil for control in potentially explosive areas Type BZ

Raritan PX. Power Cord Installation Guide. Safety Guidelines. Safety Instructions

POWERWARE User s Guide VA.

BroadBand PowerShield. 20 AHr Battery. User Manual

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

High Frequency SineWave Guardian TM

Ex m Solenoid Operator Type 0519

Solenoid Operator 0513 / 1213

Switching DC Power Supply

BK BK A BK MA BK MA BK J93 MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

362 Clamp Meter. Users Manual

1000mA - 650mA Phase Dimmable LED Driver

BMRX Series ROTARY LEVEL CONTROL

Powerware Vdc Extended Battery Cabinet User s Guide.

650mA Phase Dimmable LED Driver

Safety Standards. Model Number:

- Wiring Brochure Zone Manager 335

Installation Guide. Marine Filter SURT023M SURT024M

Mini Multimeter with Non-Contact Voltage Detector (NCV)

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

EStrong-series Emergency Stop

A419ABG-3C Electronic Temperature Control

- Wiring Brochure Zone Manager 336

INSTALLATION AND SERVICE INSTRUCTIONS FOR 2000 SERIES FLAMEPROOF XENON AND FLUORESCENT BEACONS

Automatic Pressure Calibrator. 3-Year Limited Warranty. See the Users Manual for the full warranty.

SLA Battery Capacity Analyzer

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

VA-7450 Series. Electric Valve Actuators

Start UP Guide. Symmetra LX Tower Rack-Mount. UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

Power Distribution Units

TBX-1328 High-Accuracy Isothermal Terminal Block

2000 Series Flameproof Xenon and Fluorescent Beacons Installation and Service Instructions

Tina 4A Connection block

CONTROL MICROSYSTEMS Power Supply. Hardware Manual

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

ToughPIX 2300XP Series INSTRUCTIONS FOR SAFE OPERATION

Model Fixed Rack-Mount Kit

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

INTERNATIONAL METAL ENGINEERING

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

707Ex. Users Manual. ma Calibrator

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

DALI 650mA LED Driver

2-Year Limited Warranty. See the Users Manual for the full warranty.

Flex Amplifiers Installation Instructions

Phase Sequence Tester

BK BK J93 MA BK MA BK MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

323/324/325 Clamp Meter

Installation Instructions

InfraStruXure PDU Power Cable

1000 Series Piston Type Differential Pressure Gauges

IQL Helios Area-/Streetlight. User Manual

1100 Series Piston Type Differential Pressure Gauges

INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY

- Wiring Brochure Universal Reset Module 422

Operating Instructions (Translation)

SynergEX Panelboards for Hazardous Locations

ILED Dorado. User Manual

Leica GKL341 User Manual. Version 1.0 EN

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

Transcription:

GETTING STARTED GUIDE NI 9244 3 AI/1 Neutral, 400 Vrms L-N/690 Vrms L-L, 24 Bit, 50 ks/s/ch Simultaneous

This document explains how to connect to the NI 9244. Note Before you begin, complete the software and hardware installation procedures in your chassis documentation. Note The guidelines in this document are specific to the NI 9244. The other components in the system might not meet the same safety ratings. Refer to the documentation for each component in the system to determine the safety and EMC ratings for the entire system. Safety Guidelines Operate the NI 9244 only as described in this document. Caution Do not operate the NI 9244 in a manner not specified in this document. Product misuse can result in a hazard. You can compromise the safety protection built into the product if the product is damaged in any way. If the product is damaged, return it to NI for repair. 2 ni.com NI 9244 Getting Started Guide

Hazardous Voltage This icon denotes a warning advising you to take precautions to avoid electrical shock. Safety Voltages Connect only voltages that are within the following limits. Maximum working voltage, channel-to-earth ground Up to 2,000 m altitude Continuous Up to 5,000 m altitude Continuous 400 Vrms, Measurement Category III 400 Vrms, Measurement Category II or 300 Vrms, Measurement Category III Division 2 and Zone 2 hazardous locations applications Channel-to-earth ground 300 Vrms, Measurement Category III Measurement Category II is for measurements performed on circuits directly connected to the electrical distribution system. NI 9244 Getting Started Guide National Instruments 3

This category refers to local-level electrical distribution, such as that provided by a standard wall outlet, for example, 115 V for U.S. or 230 V for Europe. Measurement Category III is for measurements performed in the building installation at the distribution level. This category refers to measurements on hard-wired hardware such as hardware in fixed installations, distribution boards, and circuit breakers. Other examples are wiring, including cables, bus bars, junction boxes, switches, socket outlets in the fixed installation, and stationary motors with permanent connections to fixed installations. Caution Do not connect the NI 9244 to signals or use for measurements within Measurement Category IV. Safety Guidelines for Hazardous Voltages If hazardous voltages are connected to the device, take the following precautions. A hazardous voltage is a voltage greater than 42.4 Vpk voltage or 60 VDC to earth ground. Caution Ensure that hazardous voltage wiring is performed only by qualified personnel adhering to local electrical standards. 4 ni.com NI 9244 Getting Started Guide

Caution Do not mix hazardous voltage circuits and human-accessible circuits on the same module. Caution Ensure that devices and circuits connected to the module are properly insulated from human contact. Caution When module terminals are hazardous voltage LIVE (>42.4 Vpk/60 VDC), you must ensure that devices and circuits connected to the module are properly insulated from human contact. You must use the NI 9969 connector backshell kit to ensure that the terminals are not accessible. Safety Guidelines for Hazardous Locations The NI 9244 is suitable for use in Class I, Division 2, Groups A, B, C, D, T4 hazardous locations; Class I, Zone 2, AEx na IIC T4 and Ex na IIC T4 hazardous locations; and nonhazardous locations only. Follow these guidelines if you are installing the NI 9244 in a potentially explosive environment. Not following these guidelines may result in serious injury or death. Caution Do not disconnect I/O-side wires or connectors unless power has been switched off or the area is known to be nonhazardous. NI 9244 Getting Started Guide National Instruments 5

Caution Do not remove modules unless power has been switched off or the area is known to be nonhazardous. Caution Substitution of components may impair suitability for Class I, Division 2. Caution For Division 2 and Zone 2 applications, install the system in an enclosure rated to at least IP54 as defined by IEC/EN 60079-15. Special Conditions for Hazardous Locations Use in Europe and Internationally The NI 9244 has been evaluated as Ex na IIC T4 Gc equipment under DEMKO Certificate No. 12 ATEX 1202658X and is IECEx UL 14.0089X certified. Each NI 9244 is marked II 3G and is suitable for use in Zone 2 hazardous locations, in ambient temperatures of -40 C Ta 70 C. If you are using the NI 9244 in Gas Group IIC hazardous locations, you must use the device in an NI chassis that has been evaluated as Ex nc IIC T4, Ex IIC T4, Ex na IIC T4, or Ex nl IIC T4 equipment. 6 ni.com NI 9244 Getting Started Guide

Caution The system shall only be used in an area of not more than Pollution Degree 2, as defined in IEC 60664-1. Caution The system shall be mounted in an ATEX/IECEx-certified enclosure with a minimum ingress protection rating of at least IP54 as defined in IEC/EN 60079-15. Caution The enclosure must have a door or cover accessible only by the use of a tool. Electromagnetic Compatibility Guidelines This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) stated in the product specifications. These requirements and limits provide reasonable protection against harmful interference when the product is operated in the intended operational electromagnetic environment. This product is intended for use in industrial locations. However, harmful interference may occur in some installations, when the product is connected to a peripheral device or test object, or if the NI 9244 Getting Started Guide National Instruments 7

product is used in residential or commercial areas. To minimize interference with radio and television reception and prevent unacceptable performance degradation, install and use this product in strict accordance with the instructions in the product documentation. Furthermore, any changes or modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory rules. Special Conditions for Marine Applications Some products are Lloyd s Register (LR) Type Approved for marine (shipboard) applications. To verify Lloyd s Register certification for a product, visit ni.com/certification and search for the LR certificate, or look for the Lloyd s Register mark on the product. Caution In order to meet the EMC requirements for marine applications, install the product in a shielded enclosure with shielded and/or filtered power and input/output ports. In addition, take precautions when designing, selecting, and installing measurement probes and cables to ensure that the desired EMC performance is attained. 8 ni.com NI 9244 Getting Started Guide

Preparing the Environment Ensure that the environment in which you are using the NI 9244 meets the following specifications. Operating temperature -40 C to 70 C (IEC 60068-2-1, IEC 60068-2-2) Operating humidity (IEC 60068-2-78) Pollution Degree 2 Maximum altitude Indoor use only. 10% RH to 90% RH, noncondensing 5,000 m Note Refer to the device datasheet on ni.com/manuals for complete specifications. NI 9244 Getting Started Guide National Instruments 9

NI 9244 Pinout AI0 0 AI1 1 AI2 2 Neutral 3 10 ni.com NI 9244 Getting Started Guide

Table 1. Signal Descriptions Signal AI Description Analog input signal connection referenced to the Neutral signal Neutral Referenced, single-ended analog input connection Connecting Phase Measurements The NI 9244 accepts three-phase and single-phase measurement configuration. Three-Phase Measurement Configurations NI recommends the following three-phase connection types. NI 9244 Getting Started Guide National Instruments 11

4-Wire WYE Measurement Configuration Phase A AI0 Phase B AI1 Phase C AI2 Neutral Neutral NI 9244 12 ni.com NI 9244 Getting Started Guide

High-Leg Delta Measurement Configuration Phase A AI0 Phase B AI1 Phase C AI2 Neutral Neutral NI 9244 NI 9244 Getting Started Guide National Instruments 13

3-Wire Delta Measurement Configuration Phase A AI0 Phase B AI1 Phase C AI2 NI 9244 14 ni.com NI 9244 Getting Started Guide

Corner Grounded 2-Wire Delta Measurement Configuration Phase A AI0 Phase B AI1 Phase C AI2 NI 9244 The 9244 cannot measure the entire tolerance range or high crest factor signals on 690 Vrms systems in this configuration. Connecting Single-Phase Measurement Configurations NI recommends the following single-phase connection types. NI 9244 Getting Started Guide National Instruments 15

3-Wire Measurement (Split Phase) Configuration AI0 AI1 Neutral NI 9244 2-Wire Measurement AI0 Neutral NI 9244 16 ni.com NI 9244 Getting Started Guide

Connection Guidelines You must use 2-wire ferrules to create a secure connection when connecting more than one wire to a single terminal on the NI 9244. Make sure that devices you connect to the NI 9244 are compatible with the module specifications. To ensure that measurements to chassis ground are correct, NI recommends connecting the chassis to earth ground using the chassis grounding screw. Refer to your chassis manual for information about connecting the chassis to earth ground. High-Vibration Application Connections If your application is subject to high vibration, NI recommends that you follow these guidelines to protect connections to the NI 9244: Use ferrules to terminate wires to the detachable connector. Use the NI 9969 backshell kit. NI 9244 Getting Started Guide National Instruments 17

Wiring the NI 9969 Caution For safe operation with hazardous voltages, you must use the NI 9969 Connector Backshell with the 4-terminal connector on the NI 9244. Complete the appropriate procedure for each wire gauge. Installing the NI 9969 Using 12 AWG to 14 AWG Wire What to Use NI 9969 backshell 12 AWG to 14 AWG wire Smallest strain-relief piece Screwdriver 18 ni.com NI 9244 Getting Started Guide

What to Do 1 2 1. Route wires under the smallest strain-relief piece. 2. Secure the smallest strain-relief piece and the backshell in place using captive screws. NI 9244 Getting Started Guide National Instruments 19

Installing the NI 9969 Using 16 AWG Wire What to Use NI 9969 backshell 16 AWG wire Small and large strain-relief pieces Screwdriver 20 ni.com NI 9244 Getting Started Guide

What to Do 1 2 1. Route wires between the two strain-relief pieces, with the small strain-relief piece on top of the wires and the large strain-relief piece underneath the wires. 2. Secure the strain-relief pieces and the backshell in place using captive screws. NI 9244 Getting Started Guide National Instruments 21

Installing the NI 9969 Using 18 AWG to 24 AWG Wire What to Use NI 9969 backshell 18 AWG to 24 AWG wire Largest strain-relief piece Screwdriver 22 ni.com NI 9244 Getting Started Guide

What to Do 1 2 1. Route wires under the largest strain-relief piece. 2. Secure the largest strain-relief piece and the backshell in place using captive screws. NI 9244 Getting Started Guide National Instruments 23

Converting L-N Measurements to L-Earth To convert L-N measurements to L-Earth values, add the neutral channel reading to each AI channel reading. Refer to the following equation for an example of converting L-N measurements to L-Earth. Line to Earth = AIx + Neutral where AIx is the analog input channel reading Neutral is the Neutral channel reading Converting L-N Measurements to L-L To convert L-N measurements to L-L values, calculate the voltage difference between the AI channels using your application software. Refer to the following equation for an example of converting L-N measurements to L-L. Phase A to Phase B Voltage = AI0 - AI1 24 ni.com NI 9244 Getting Started Guide

where AI0 is the reading from Phase A AI1 is the reading from Phase B NI 9244 Getting Started Guide National Instruments 25

Where to Go Next CompactRIO NI CompactDAQ NI 9244 Datasheet NI-RIO Help LabVIEW FPGA Help NI 9244 Datasheet NI-DAQmx Help LabVIEW Help RELATED INFORMATION C Series Documentation & Resources ni.com/info cseriesdoc Services ni.com/services Located at ni.com/manuals 26 ni.com NI 9244 Getting Started Guide Installs with the software

Worldwide Support and Services The NI website is your complete resource for technical support. At ni.com/support, you have access to everything from troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers. Visit ni.com/services for NI Factory Installation Services, repairs, extended warranty, and other services. Visit ni.com/register to register your NI product. Product registration facilitates technical support and ensures that you receive important information updates from NI. A Declaration of Conformity (DoC) is our claim of compliance with the Council of the European Communities using the manufacturer s declaration of conformity. This system affords the user protection for electromagnetic compatibility (EMC) and product safety. You can obtain the DoC for your product by visiting ni.com/certification. If your product supports calibration, you can obtain the calibration certificate for your product at ni.com/calibration. NI 9244 Getting Started Guide National Instruments 27

NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504. NI also has offices located around the world. For telephone support in the United States, create your service request at ni.com/support or dial 1 866 ASK MYNI (275 6964). For telephone support outside the United States, visit the Worldwide Offices section of ni.com/niglobal to access the branch office websites, which provide up-to-date contact information, support phone numbers, email addresses, and current events. Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the NI global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/ export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. 2016 National Instruments. All rights reserved. 376131D-01 Apr16