SILENCER ACCESSORIES

Similar documents
Vent/Fan Silencers UNIVERSAL. Vent/Fan Silencers ENERGY ENVIRONMENTAL

VENT SILENCER PRODUCT GUIDE

MATERIALS & STANDARDS

AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS

1. SPECIFICATION. Altitude of motor installation. Information: Resistance and temperature specifications of the PTC thermistor / posistor/.

MCS TYPE B FOAM MAKER & FOAM CHAMBER NDD010. Approvals: UL, ULC

JUNCTION BOXES AND SUNSHADES

GmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV. vertical outlet. Issue 07/02

LINE SILENCER. Copyright 2009 by PULSCO Incorporated. All rights reserved. Reproduction without permission is prohibited.

Features Four Sizes Superior Foam Quality Operates at 30 PSI (2.1 bar) minimum Tool Free Maintenance Corrosion Resistant Polyester Finish

TECHNICAL DATA OBSOLETE

Highline 260i EC Waterside Fan Coil Unit

SECTION HVAC AIR CLEANING DEVICES

DS Series Solar System

HIGH TEMPERATURE HIGH PRESSURE CONTROL VALVES SERIES

AUXILIARY COMPONENTS

Process screen basket filter PRFS

AL-Maraj Central A/C Systems Accessories Mfg Co.

Model DW Series Positive Pressure Guidelines for Engine Exhaust Systems

26 - COOLING SYSTEM CONTENTS ENGINE COOLING - DESCRIPTION... 3 ENGINE COOLING - OPERATION... 9 COOLING SYSTEM FAULTS... 1

Fresh air and exhaust air systems

ELTAFANTECH Air Handling Unit 700 up to 42,000 CFM

SECTION AXIAL HVAC FANS

Outside Louvers. Series OHCL, OHL, OHL-CD, OHL-D, OHL-KD, OHL-LAOGS, OHL-LOUVER DOOR, OHL-ST2/ST4, OVL & PHL

Model DW Series Positive Pressure Guidelines for Engine Exhaust Systems

SLUDGE DEWATERING. The costs for trucking sludge to the ultimate disposal site become substantially lower when sludge volume is reduced by dewatering.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

1/11 29/06/2016 CONTENTS 1. GENERAL DUCTS, AIR VENTS, VALVES MONOBLOCK UNITS FILTRATION CONTROL...

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03

Sand Trap Louvers OSTL 300 SERIES. Sand Trap Louvers

Cylindrical Silencers

COOLING SYSTEM - V8. Cooling system component layout DESCRIPTION AND OPERATION

Exhaust System - 2.2L Diesel

Please note this is a condensed catalog. For a complete version, contact Velan directly.

SPARE PART LIST LW 300 E & LW 450 E

where nature and technology meet FILTRATION Solutions for filtration applications PETROGAS GAS-SYSTEMS BV

SMALL PROTECTIVE VENT

PSI CASING END SEALS FOR CASING PIPE CLOSURE FOR PROTECTION AGAINST MOISTURE AND DIRT ALSO FOR RETROFITTING INDIVIDUAL CUSTOMIZED SOLUTIONS

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

Daikin Steam Coils. Installation and Maintenance Manual IM 901. Types HI-F5, HI-F8, & E-F5. Group: Applied Air. Part Number: IM 901

Bracket U Value at 1.5M Centres. 265mm 275mm 295mm 300mm 315mm 335mm 355mm mm.

INSTRUCTIONS INSTALLATION OF NEMA-3R KIT FOR 43, 44 & 52 FRAME AF-6 DRIVES INTO WELDED ENCLOSURES

VAD Variable Area Desuperheaters

SM Range - a wide range of silencers adapted for all applications :

Air distribution product

Trelleborg Specialty Mining Hoses

ARMASOUND INDUSTRIAL SYSTEMS THE FIRST SOUND CONTROL SYSTEMS TO MINIMISE THE RISK OF CORROSION UNDER INSULATION (CUI)

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

Process Inline Filter Protective filter PLF2-9HF

TYPICAL SPECIFICATION: Critical Process Roof Top Unit 7/14/15

Reading this manual. Preface

Industrial Generator Set Accessories

SUCTION FILTRES. 3D drawings available at

Spark arrestor type C

Installation manual. Exhaust system. Marine engines DI09, DI13, DI16. 02:04 Issue 9.0 en-gb. Scania CV AB 2017, Sweden

Vent Silencers An Overview

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER E: THE REACTOR COOLANT SYSTEM AND RELATED SYSTEMS

Fantronix Hydroponic Wholesale Price List. July 2014 Revision 1

EQUIPMENT FOR FILTRATION OFAIR

1mm GALVANIZED PIPE SYSTEM

PFA LINED BALL VALVES Installation, Operation and Maintenance Manual

N-084M and N-069M-DV Series Heat Exchanger Replacement

Design specifications

KSI Filtertechnik GmbH Siemensring D Willich Tel Fax

Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System

PRIMEX VENTING PRODUCTS AND ACCESSORIES

A E R Z E N S C R E W C O M P R E S S O R S

Section 03 Marine and Mooring Equipment - Sales Item

The UL Type 3R Package is specifically designed for Adjustable Frequency Drives, such as Yaskawa's E7, F7, G7, P7, and iqpump models.

first flust water diverters water quality first downpipe, post/wall mounted and in-ground diverters

MOTORIZED VOLUME DAMPER

Industrial Generator Set Accessories

KVA POWERHOUSE RANGE 1250 KVA 1700 KVA

Product Catalog Evacuated tube collectors CPC OEM CPC w OEM

3- and 4-Way Ball Valves KH3/KH4

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS

Absorptive Silencers UNIVERSAL. Absorptive Silencers ENERGY ENVIRONMENTAL

Horizontal Pre-Piped Bladder Tanks with Proportioner

Building Integrated Duct System

Water Pump Replacement (L4)

Inductive voltage transformers

Vertical Pre-Piped Bladder Tanks with Proportioner

Installation Instructions for Bike Fixtation. Bottle Fill and Bike Wash Stations Manual Rev. B

The Anatomy of a Drum Filter

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating.

Model MTB-ASME Vertical Pre-Piped Bladder Tanks

SAND FILTERS. Models: ECSF500, ECSF650, ECSF700, & ECSF800

Rain Harvesting Pty Ltd

SILOXA frame-mounted gas drying system, GK model, set up for outdoor installation

Appliance nomenclature

Circular Manways. There is an array of different lid designs, hinge positions and sealing arrangements, to suit your application.

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

MegaBox Product-specific information

Industrial Generator Set Accessories

Includes Dry Gas Design. Performance Enhanced with PEACH Cartridge Technology FILTRATION. All Rights Reserved Patent Pending I X H E L A P P L

MODEL NUMBER NOMENCLATURE. The model described above is a Side Access Housing, 4,000 CFM, 2 stages PX1224 cells, epoxy coated construction.

Model MTB-ASME Horizontal Pre-Piped Bladder Tanks

McKenzie Martin Louvres & Ventilation Systems Louvres Maximair Louvre Systems Turret Louvres

Combi2 TTW Models (CSW2TW, CDW2TW)

Complete HVAC Capability

Transcription:

GLAUNACH THE SILENCER HANDBOOK SILENCER ACCESSORIES CUSTOMISING SILENCERS TO SPECIFIC NEEDS GLAUNACH GMBH 2010 - ALL RIGHTS RESERVED -

Part III page 2 of 10 LIFTING LUGS device transport and installation all products all GLAUNACH products are by default equipped with suitable lifting lugs typically manufactured from silencer shell (carbon steel or stainless steel) IDENTIFICATION PLATE device identification and information all products all products are equipped with an ID plate by default anodised aluminium stainless steel plates are available at extra charge PRESSURE GAUGE standard connect port for pressure or temperature sensors for monitoring e.g. the silencer inlet all silencers on customers request ½ BSW Whitworth thread, closed with a fitting plug available in carbon steel or stainless steel

Part III page 3 of 10 DEWATERING PIPE drainage for condensation and rainfall all GLAUNACH are by default equipped with a suitable dewatering device typically manufactured from silencer shell (carbon steel or stainless steel) EAVES RING drip ring for diverting rain water away from the gas inlet connection point for external insulation weld-on element, typically silencer shell (carbon steel or stainless steel) COLLAR SHEET drip mould for draining rain water from the gas inlet connection point for external insulation in-roof vent silencer installations weld-on element, typically silencer shell (carbon steel or stainless steel)

Part III page 4 of 10 BRACKETS support and fixation all products weld-on elements, typically shell (carbon steel or stainless steel) STANDS support all products weld-on elements, typically same grade materials as the shell (carbon steel or stainless steel) GOOSE NECK redirection of gas flow, e.g. away from a nearby wall customised to application requirements and installation conditions typically manufactured from silencer shell (carbon steel or stainless steel)

Part III page 5 of 10 WEATHER HOOD RAIN & SNOW protection against ingress of precipitation (rainfall & snow) hood typically manufactured from same grade material as the silencer shell (carbon steel or stainless steel); the inner surface of the weather hood is equipped with a noise absorbing layer to minimise noise emission WEATHER HOOD RAIN, SNOW, SAND & DUST protection against ingress of precipitation (rainfall & snow) and air-borne particulate matter (sand & dust) hood with integrated dust trap, typically manufactured from same grade materials as the silencer shell (carbon steel or stainless steel) The hood comes equipped with a separate dewatering pipe for rinsing the dust trap, and is easily removable for maintenance.

Part III page 6 of 10 OUTLET EXTENSION extension of the silencer outlet customised to application requirements and installation conditions typically manufactured from silencer shell (carbon steel or stainless steel) BIRD SCREEN preventing birds and other animals from nesting inside the silencer bird screens can also be used for operator protection and to prevent tools, etc. from dropping into the silencer stainless steel grating covering the silencer outlets, either peripherally or axially NOTE: peripheral bird screens can only be used in combination with the Rain & Snow weather hood

Part III page 7 of 10 FLANGES detachable connection of pipes all pipe connections gas inlets, in-line silencer outlet, drains, etc. according to customer requirements and applicable standards available as either single flange or flange kit (incl. nuts, bolts, gasket and 2 nd flange) MULTIPLE INLETS muffling two or more lines with one silencer customised to specific customer requirements; standard solutions include multiport direct diffuser inlets and dedicated collecting pipes EXCHANGEABLE DIFFUSER CARTRIDGE replaceable diffuser for media containing particulate or aggressive matter, which may obstruct or corrode the diffuser stage over time diffuser silencers multi-layer wrapped finely woven stainless steel wire mesh in diffuser pipe cage

Part III page 8 of 10 ABSORBER noise reduction by flow splitting and noise absorption concentric circular baffle elements, composed of perforated stainless steel sheets encasing heat resistant longstrand glass fabrics and mineral wools absorbing mats HEATER prevention of freezing of precipitation or condensate recommended accessory for: regions with very low ambient temperatures applications, where no heat is transferred from the line to the silencer easily replaceable stainless steel heating cartridge, mounted in a steel block welded to the silencer bottom; electrical connection clamps and thermostat are located in an aluminium shell affixed to the rear end of the heating cartridge silencers up to 2 m external diameter require 200 W heating power; for larger sizes, the heating power should be increased to 400 W heater installation requires a 110 / 230 V AC connection; the installation of an additional operation control indicator in the control room is recommended

Part III page 9 of 10 EXPANSION JOINTS accommodating relative movement, caused e.g. by thermal expansion in supported installations stainless steel pressurised or non-pressurised expansion joints SLIDING BRACKETS accommodating horizontal movement, caused e.g. by thermal expansion in supported installations modified steel brackets facilitating lateral movement SLIDING DIFFUSER accommodating vertical movement, e.g. due to thermal expansion noise decoupling of solidborne sound from upstream installation in supported installations diffuser stage bedded in an adjustable gland seal, enabling reciprocating relative movement of diffuser stage and silencer shell

Part III page 10 of 10 INSULATION CLIPS fastening of supplementary thermal / acoustic mineral wool insulation spikes 1) clamps 1) 1) Please refer to Part VIII Insulation of THE SILENCER HANDBOOK for more.