HIDEAWAY ACTIVE SENSOR-FLUSH URINAL

Similar documents
ROCA THE GAP BACK TO WALL TOILET SUITE

HIDEAWAY PLUS IN-WALL CISTERN (BACK TO WALL PAN)

ROCA KHROMA TOILET SUITE

Damage caused by any improper treatment is not covered by the product warranty. Refer to Warranty Conditions.

MECHANICAL UNDER COUNTER 150 CONCEALED CISTERN (BTW)

SIGMA PNEUMATIC CARE BUTTON

OMEGA UNDER COUNTER MECHANICAL BTW 4S CONCEALED CISTERN

DOMINIQUE MKII wall hung vanity 900mm. Wall Hung Vanity 900mm (Left Hand Bowl) Cabinet Only - Front View Cabint Only - Side View

DOMINIQUE MKII SEMI RECESSED vanity

HIDEAWAY PLUS UNDERCOUNTER CISTERN (WALL HUNG PAN)

AXA Cento semi wall basins with shelves

ALAPE METAPHOR UNDERCOUNTER BASIN

INSTALLATION MANUAL. Installation Details Warranty Wolfen 122 Wall Bubbler Wolfen 90 Wall Bubbler Wolfen Hob Bubbler

ROCA DUO PLUS OVAL INSET BATH

TOUCH-ACTIVATED DUAL FLUSH WC FLUSHING SYSTEM - FRONT ACCESS

INSTALLATION MANUAL. Installation Details Warranty Wolfen Pre Rinse Sink Mixer Wolfen Compact Pre Rinse Sink Mixer

SIGMA75 PNEUMATIC CONCEALED CISTERN (BTW)

3.0 INSTALLATION INSTRUCTIONS. Avon 21 Self-closing taps (Push button) B0992AA Self-closing basin pillar tap

INSTALLATION MANUAL. Installation Details Warranty Wolfen Hand Held Trigger Spray Assembly With Stop Tap

TOUCH-ACTIVATED URINAL FLUSHING SYSTEM SLIM STYLE PANEL - LARGE (FRONT ACCESS)

MIZU QUICK CHANGE DUAL FILTER SYSTEM

flushing systems SMART CHOICES FOR HYGIENE AND WATER EFFICIENCY BUILT IN VANDAL RESISTANCE Toilet Flushing Systems Urinal Flushing Systems

FRANKE BOW SINGLE BOWL

ROUND REMOTE BUTTONS AND PLATE (IN-WALL)

FOR NEW ZEALAND. T-604 WASTE DISPOSER B. HYDRAULIC CHARACTERISTICS &TECHNICAL SPECIFICATIONS. DECLARATION OF COMPLIANCE

INSTALLATION AND MAINTENANCE GUIDE TUBULAR SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

Breezair TBA 550 Installation Manual

Zip FlushMaster Solo Water Saver Urinal Flushing System Keeps Urinals Clean & Reduces Water Wastage

INSTALLATION AND MAINTENANCE GUIDE SF1596 B/E ELECTRONIC LAVATORY FAUCET

Zip FlushMaster Surface mounted sensor

INSTALLATION MANUAL. Installation Details Warranty Wolfen Foot Operated Pedal Valve Wolfen Foot Operated Kit with Outlet

ETF-600 Sensor Operated Lavatory Faucet

INSTALLATION MANUAL Wolfen Cleaners Sink With Grate. Installation Details Warranty

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

Homeowner s Guide. For Dual-Flush Toilets A5-H

INSTRS30709 rev 1 02/10/09 Page 1

Key Installation Points. Table of Contents

HANDS FREE FOOT & KNEE OPERATED TAPWARE

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

Infrared Control Valve Installation Guide

Infrared Control Valve Installation Guide

PLEASE READ. Easy Installation

D28 SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER. D28 B D28 E D28 Dual Power B D28 Dual Power E D28 Box D28 Box E

Instruction Booklet. P.O. Box Berkeley Rd UNANDERRA,NSW 2526 Australia Tel:

Airfield Industrial Estate Hixon Staffordshire ST18 0PF

Installation and Maintenance Guide SF1593 SF1594 B/E ELECTRONIC LAVATORY FAUCET

3.0 INSTALLATION INSTRUCTIONS. Piccolo 21 Single lever Monobloc basin mixers. B0997AA Single lever basin monobloc mixer with long length lever handle,

INSTALLATION AND MAINTENANCE GUIDE ELITE SERIES ELECTRONIC LAVATORY FAUCET

DOOR/S WITH INTERNAL FIXED SHELF - TOUCH RELEASE & CORIAN HANDLE OPTIONS. American Oak, Charcoal Oak, Pony Oak, Hazelnut Oak

INSTALLATION AND MAINTENANCE GUIDE EXTREME WM WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

Installation must be in Accordance with AS/NZS

BC632 / BCL632 BC635 / BC635

Technical Information & Warranty

A wave does it! Zenith Touch-Free Washroom Technology

Bianco Rainsaver MK3 Installation and Operating Instructions. The no brainer. Bianco Rainsaver MK3 & MK3E Installation and Operating Instructions

Inst all a ti o n and Oper a tin g Instru c ti o n s

INSTALLATION MANUAL. Installation Details Warranty Wolfen Folding Shower Seat 600mm Wolfen Folding Shower Seat 960mm

APP Environmental Services P/L.

INSTALLATION MANUAL IMPORTANT CONSIDERATIONS TECHNICAL INFORMATION. Tools you may need

FASHION SKIRTED TOILET FOR P & S TRAPS DUAL FLUSH OWNER S MANUAL ITM. / ART # QTA023

STRUKTURA T01-A INSTALLATION INSTRUCTIONS

POSITIVE DISPLACEMENT FLOWMETERS

VR2-CC VR2-RS VR2-ES PRODUCT MANUAL

Mira Mode Shower and Bath Fittings

Bianco RainsaverMK4E Installation and Operating Instructions

Part No: Genuine Mira Accessories

GLOSS WALL BATH SET PRODUCT CODE: FINISH: GS783 CHR CHROME CONTEMPORARY DESIGN PHOENIX WARRANTY STYLISH PREMIUM CHROME FINISH MATCH WITH...

IRC Urinal Flush Control Valve

IRC urinal flush control valve

LED Reference for Circuit Board

INFRARED TAPS. Important: Electronic taps saving water, saving power, promoting hygiene DB100 DB125 DB150 DB175 DBL200 DBL225 DBL250 DBL275

Installation Instructions

Homeowner Guide. Dual-Flush Two Piece Toilet A5-N

Operators Guide: RoboSign Stop/Go Traffic Control System

Operators Guide: RoboSign Stop/Go Traffic Control System

EZ FILL FAUCET AUTOMATIC DECK MOUNTED FAUCET INSTALLATION AND MAINTENANCE GUIDE

EAFM, EAFC & EAFN Filters Installation and Operating Instructions

THERMOSTATIC INLINE CONTROL SHOWER VALVES Installation & aftercare instructions

Installation and Operating Instructions for Davey HM Series Pressure Systems with Pressure Switch

VIVID SLIMLINE FLOOR MOUNTED BATH MIXER PRODUCT CODE: FINISH: VS745 CHR CHROME STYLISH PREMIUM FINISH CONTEMPORARY DESIGN PHOENIX WARRANTY

Urinal Flushing. Hydraulic Valve Infrared Control (IRC) Valve Direct Flush

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED FLUSHOMETER WITH WALL BOX CONCEALED CLOSET & URINAL INSTALLATIONS

Bianco RainsaverMK6 uses WaterMarked components and incorporates a dual check valve for back flow prevention for the mains water.

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets

Dolphin Blue Infrared Taps

Your Guide to the Installation, Care and maintenance of PERFORMA. Electronic Self Closing Fittings - Mains Powered 886V (343029) 885V (343027)

RUSH SHOWER/BATH DIVERTER MIXER PRODUCT CODE: FINISH: RU791 CHR CHROME CONTEMPORARY DESIGN PHOENIX WARRANTY STYLISH PREMIUM CHROME FINISH

EVAC Commercial Marine Equipment TOILET TECHNICAL DATA EVAC 90, STAINLESS STEEL, FLOOR MODEL, *SHOCK TESTED. Fresh water.

ELECTRONIC FLUSH VALVE FOR URINALS jupiter 2040

ENWARE-ORAS ELECTRONIC TAPWARE Installation and Maintenance Instructions

ARQUA STATION DF4 + DF7

Flush Valve Systems. By SCHELL.

Information Booklet WW20072

INFRA RED MONOBLOC SF2601CP (BATTERY OPERATED) INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS PLEASE LEAVE THESE INSTRUCTIONS WITH THE USER

INSTALLATION MANUAL IMPORTANT CONSIDERATIONS TECHNICAL INFORMATION. Tools you may need

Troubleshooting. This section outlines procedures for troubleshooting problems with the operation of the system:

Zenith Aqua Sense Taps

Subject Underhood G System Error Codes and Symptoms System or Parts affected

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

3.1 DISPENSER BLACK SHADOW SERIES. Tools Needed for Mounting SCS Dispenser Hammer

Transcription:

Fixing Template To wall with L shape bracket supplied Including in packaging WELS Watermark Standards Warranty 3 Star rating, average ush 1.2 litres WMKT21654.4 AS/NZS 6400:2005 12 months warranty (see below) page 1 of 16 350 279 Φ10 299 571 33 269 SPECIFICATIONS Recommended Use Domestic, hotel and commercial Urinal Vitreous China American Standard Active Urinal WARRANTY & CARE DETAILS Normal wear and tear Dear Customer, White Inadequate or complete lack of maintenance This is the warranty by Reece Pty. Ltd. relating to this product. Please keep it together with your purchase receipt. In the unlikely event of Concealed rear inlet DN20 and kee seal Water Inlet a query please contact your nearest Reece Plumbing Centre. Cleaning Recommendations Plastic Trap is supplied with kee seal for push-in Outlet connection to DN50 waste pipe Any sanitaryware should not be cleaned with abrasive materials Warranty eg. steel wool/scourers. Do not use any corrosive or abrasive cleaning You have purchased a quality product from Reece Australia. This Inwall, suitable for minimum cavity wall thickness Application agents containing acids or scouring agents. product is covered byofa 90mm, twelve month Induct,warranty. Ceiling This warranty covers faults in the product construction, material and assembly. FaultyIn the event of a warranty claim, we will replace or repair defective prodmaximum 2000mm from urinal inlet Flush Pipe Heightwill be repaired d products or exchanged free of charge. Faulty items be-ucts, or pay for the cost of having defective products repaire or replaced, but will not be liable for any injury to any person, damage to come our property. Minimum 500mm from urinal inlet any property, any indirect or consequential loss, or in any other respect. This warranty does not include faults caused by: L shape Urinal Fixing Unsuitable or improper use brackets supplied Incorrect installation Included in packaging Template Installation or part installation by the purchaser or any person other than a LICENSED PLUMBER tradesman WELS 6orstar rating (0.8L/flush) Water Saving Colour Sensor models Push button flush volume adjustment based on Easy to Adjust Easy to Install 240V AC (transformer) or 6 V DC (battery pack) WMK T21654.4 Disclaimer: the dynamic supply pressure To see the complete Products in this speci cation manual must by regulation be installed by licensed and registered trade people. The manufacturer/diswww.reece.com.au/bathrooms Dimensions and set-outs tributor reserves the right to vary speci cations or delete models from their range without prior noti cation. with all mounting hardware takes no responsibility for printing errors. listedsupplied are correct at complete time of publication however the manufacturer/distributor Tech and Page Version 1 cables Sensor Technology Prevents false detection Normal Mode In Normal mode the unit will flush after every use Eco Mode Setting Additional water conservation for high traffic bathrooms. A flush is only activated after the third user has visited or 15 minutes has elapsed, whichever comes first. Saver Mode When high frequency usage is detected in Normal mode, the unit will switch to Saver mode to conserve water. Hygienic Urinal automatically flushes touch free after use. Janitors Flush Triggers and automatic hygiene flush after 48 hours of non-use. Over-flow Protection Sensor can detect blockages and will stop flushing to prevent urinal overflow Fault finding Self diagnostic fault finding Technical Support If you have any questions or queries during installation please contact Tech-Support for phone assistance free call 07 3875 2465 We are happy to assist you. The more stars the more water efficient WATER RATING www.waterrating.gov.au 0.8 litres per flush per stall In accordance with AS/NZS 6400 Licence No. 0025 Reece Limited Disclaimer: Products in this specification manual must by regulation be installed by licensed and registered trade people. The manufacturer/distributor reserves the right to vary specifications or delete models from their range without prior notification. Dimensions are nominal measurements only. Dimensions and set-outs listed are correct at time of publication however the manufacturer/distributor takes no responsibility for printing errors. Tech Page Version 4 range go to

page 2 of 16 INSTALLATION INSTRUCTIONS 1.0 Check contents of packaged unit: - Flush control unit is fitted with short 100mm cables for sensor and power and 1500mm long cable for solenoid flush valve connection - Solenoid valve is fitted with 200mm cable and 2 pin connector (Fig. 1) - Cables are supplied as follows: Sensor extension cable 2500mm long with female/male 4 pin connectors 1800mm power cable wired with single male connector one end and other end hard wired to a transformer/power supply (AC adaptor 240V AC/6V DC) Flush control unit Fig. 1 - Flush valve kit (Fig. 2) consisting of an isolation/shutoff valve, solenoid valve and vacuum breaker/air break Fig. 2 - Active urinal complete with paper template, wall mounting brackets and screws Note: Optional battery powered model is also available

page 3 of 16 2.0 Rough in wall preparation: Note: All plumbing installation work has to be carried out in accordance with AS/NZS 3500. Installation requirements may vary, please check with your local authority. 1. Determine mounting height of urinal based on recommended height to front edge (610mm) 2. Fit timber noggin into wall cavity to support urinal mounting brackets (Fig. 3) 3. Fit 20mm copper inlet pipe supported rigidly in wall allowing at least 30mm proud of finished wall and remove burr from pipe end (Fig. 4). The flush pipe should be installed without offsets. IMPORTANT: Accuracy is required to maintain 495mm centre distance between inlet and outlet 4. Trap outlet seal fits straight into the inside of 50mm DWV PVC pipe 5. Minimum 20mm water supply to this urinal is required as per AS/ NZS 3500 6. Install flexible electrical conduit (32mm minimum size, not supplied) free of kinks for sensor extension cable (Fig. 4) 7. Fit single 240 volt 10 amp GPO for transformer/powersupply unit adjacent to proposed location of controller Fig. 4 Fig. 3 3.0 Control Unit Connection: 1. Ensure rough in wall details have been completed first as detailed in Figs. 3 and 4 2. Flush the water lines 3. Assemble flush valve components (Fig. 2) following directional arrow on solenoid valve body during assembly 4. Install flush valve as required in-ceiling (Fig.11), in-duct (Fig. 12) or in-wall (Fig. 13) 5. Flush valve must be installed in the vertical position with the isolation valve closed 6. Connect flush valve to 20mm copper flush pipe using olive fitting supplied 7. Connect water supply to flush valve (1/2 BSP male inlet) 8. Peel off tape backing on Velcro strip to mountcontrol unit directly into position 9. Make connection from flush valve to control unit using 1500mm solenoid valve cable. NOTE: Care must be taken to align pins inside each male connector with holes in female connector before pushing connectors together to prevent pins being bent. 10. Make connection of sensor cable to control unit. 11. Route sensor cable through flexible conduit and 100mm out through wall.

page 4 of 16 4.0 Urinal Installation Instructions: 1. Cut out paper template supplied, place in position flat on wall aligning centre of cut out holes with inlet and outlet. 2. Mark hole centres through template onto wall to provide wall locations for two L shaped brackets (Fig. 5). 3. Fit L shape mounting brackets to wall with fixings supplied (Fig. 6). Fig. 5 Fig. 6 4. Before fitting waste trap, cut 50mm PVC DW V flush with finished wall (Fig. 7). Fig. 7 5. Fit kee-seal to waste trap and lubricate before gently pushing into 50mm PVC DW V pipe so trap finishes flush with face of wall. Fix waste trap to wall with single screw (Fig. 8). 6. Ensure sensor cable is installed through finished face of wall and connected to trap before installing urinal. 7. Lubricate and fit rubber inlet seal to trap. Carefully lift urinal into installed position, ensuring it is fitted with: Inlet pipe fully inserted into urinal rubber inlet seal Outlet fully inserted into waste trap inlet seal Urinal mounting screws are fitted using plastic sleeves provided and tightened into L shape brackets (Fig. 9). IMPORTANT: DO NOT OVER TIGHTEN SCREWS AS THIS MAY CRACK URINAL SIDE WALL

page 5 of 16 Important! Do not seal the urinal to the wall yet. Urinal should only be sealed once urinal has been fully commissioned. Fig. 9 Fig. 8 5.0 Commissioning: If you experience any technical issues refer to the Trouble Shooting Guide first (Section 12.0). If the issue cannot be resolved, contact Tech-Support for phone assistance on free call 07 3875 2465. We are happy to assist you! 1. If mains powered, make connection from control unit to power supply unit. 2. Open the isolation valve and switch power ON (mains power model) or install battery (battery powered model) to check system function: When power is first connected to the controller, the system performs an automatic self-check to confirm that all components are functional Observe the red LED flash response on the controller There could be 3 different flashing responses A, B or C Do not press buttons on the controller yet. A LED FLASH RESPONSE FIRST TIME POWER ON 1) Initial 2 short flashes followed by steady flashes at 1 second intervals. After about 25 seconds of steady flashing sequence - the flashing will change into a rapid on and off sequence and then stop. This signals that the self-check cycle has ended. 2) After a pause of 20 seconds 2 flushes will be automatically triggered. 3) Test flush the urinal in one of two ways: A) Hold the blade of an uninsulated screwdriver with your bare hands and dip one end into the water below the grate for 2 seconds and remove. B) Pour 100ml or more of warm water into the urinal. MEANING Confirmation that the self-check has not detected a fault Trap has been filled and the system is ready for use After 10 seconds a flush will be triggered Note: Do not submerge the screwdriver for longer than 2 seconds otherwise the cleaning cycle may be activated. This will suspend flushing for 30 minutes. Also if flushed too often in quick succession the saver mode may be activated. To cancel these modes just unplug power for 30 seconds and re-connect. If you have any questions please contact Service ph. 07-3875 2465

page 6 of 16 LED FLASH RESPONSE FIRST TIME POWER ON MEANING B 1) Initial 2 short flashes followed by a sequence of double flashes in 3 second intervals. After about 25 seconds of the double flashing sequence the flashing will change into a rapid on and off sequence and then stop. This signals that the self-check cycle has ended. 2) After a pause of 20 seconds 4 short flushes will be triggered. Self-check has detected a fault with the sensor. Please switch off the power. Un-plug and re-plug every cable connection. Check that no cable has been damaged during construction. Re-connect the power and check if the LED response is as above in A. If the fault is still indicated contact Service ph. 07-3875 2465 Do not proceed with sealing the urinal with sealant to the wall. LED FLASH RESPONSE FIRST TIME POWER ON MEANING C 1) Initial 2 short flashes followed by a sequence of quick triple flashes in 2 second intervals. After about 25 seconds of the triple flashing sequence the flashing will change to a rapid on and off sequence and then stop. This signals that the self-check cycle has ended. 2) No flushes will be triggered. Self-check has detected a fault with the solenoid. Please switch off the power. 1) Unplug the solenoid valve connection. 2) Check that the pins in the male plug are not bent apart and line up with the holes in the female plug. If required use your fingers to squeeze the plug and pins together. 3) Check plug alignment and re-connect. Re-connect the power and check if the LED response is as above in A. If a fault is still indicated contact Service ph. 07-3875 2465. Do not proceed with sealing the urinal with sealant to the wall. 3. If no faults have been detected the urinal can now be sealed to the wall with anti-fungal flexible sealant. 4. Flush Time: To achieve the required flush volume, measure the dynamic water pressure that is available at the installation site. Compare your measurement with table values in Fig.10 and select the required flush time setting with Button1' on the controller. The flush time of a new controller is supplied with the setting adjusted to 375 kpa. To change flush times follow the instructions below. Dynamic w ater Pressure LED Flashes Approximate flush volume Factory setting 475 kpa 1x 800 ml 425 kpa 2x 800 ml 375 kpa 3x 800 ml 325 kpa 4x 800 ml 275 kpa 5x 800 ml Button 1 How to change the flush time A) Press Button 1 once (for 1 to 3 seconds) and the LED will indicate current controller setting by flashing 1x or 2x up to 5x - at which setting the controller currently is. Note: The LED will continue flashing in a steady repeating rhythm to indicate that the controller is still in editing mode and settings can be changed. Do not be distracted by this flashing. B) Press Button 1' again and the flush time will advance to the next flush time setting. The LED will now respond by flashing 1x or 2x up to 5x to indicate the new selected setting. C) Once the desired setting is achieved wait for approximately 20 seconds for the controller to automatically exit the edit mode. As confirmation that the controller is now ready for use 2 flushes will be automatically triggered.

page 7 of 16 5. To select a different flush program A new controller is supplied with the flush program set to Program 1. This is the normal flush mode and is the recommended setting. This program flushes after every use and will automatically switch to Saver Mode (1 flush only after every 3 rd user) when 4 users visit the urinal at less than one minute intervals. 1 minute of non-use will re-set the controller automatically to flush after every use. A janitor flush will be triggered if the urinal has not been used for 48 hours. How to change the flush program Program 2 (Eco Mode) Flush Program 2' is designed to be used only in venues with very high customer turnover that come all at once at specific time intervals such as Theatres, Stadiums and Schools. This program will flush the urinal only after every 3 rd user or 15 minutes after use, whichever comes first. It also triggers a janitor s flush after 48 hours of non-use. Button 2 To change the program, complete the following: A) Press Button 2' once (for 1 to 3 seconds) and the LED will indicate by flashing program setting. Either a short 1 second flash indicates Program 1' or a long 2 second flash indicates Program 2" Note: The LED will continue flashing in a steady repeating rhythm to indicate that the controller is still in editing mode and settings can be changed. Do not be distracted by this flashing. B) Press Button 2' again to change programs. The LED will now respond with a 1 second short flash to indicate program 1 or a 2 second long flash to confirm the selected program. C) Once the desired setting is achieved wait for about 20 seconds and the controller will automatically exit edit mode. As confirmation that the controller is now ready for use 2 flushes will be automatically triggered.

page 8 of 16 6.0 Cleaning: Cleaning of the urinal is an important part of the regular maintenance. This should not just only involve the ceramic part of the urinal. Cleaning the trap and pipe connection at regular intervals is equally important. Water can react with urine and form struvite. Struvite is a hard crystalline deposit that will form on the ceramic and inside the trap and pipe connection. Over time Struvite can build up creating a blockage. Struvite deposits have to be frequently removed with a suitable acidic type toilet cleaner at regular intervals. Cleaning agents are more effective if they soak for a certain time (refer to the cleaning agent instructions). To assist with the soaking period, the controller is equipped with a cleaning cycle that suspends flushing for 30 minutes. How to activate cleaning cycle in Program 1 (Normal Mode): 1) Hold the blade of a screwdriver with your bare hands (no gloves can be worn) into the water below the grate for 10 seconds. Whilst still holding the rod in the water pour some of the cleaning agent into the water of the urinal. 2) Now remove the rod from the water. This will trigger two short flushes which will carry the cleaning agent to the back of the trap and pipe connection. Now the flushing is suspended for 30 minutes. 3) Add more of the cleaning agent to the water of the urinal. After 30 minutes a flush will automatically trigger and the urinal is ready for use. How to clean in Program 2 (ECO Mode): In Program 2 which flushes after every third user or approximately 15 minutes after use whichever is first, cleaning may be done within 15 minutes in 2 ways. A) The cleaner can visually check if the urinal has been flushed. If it has been flushed proceed as follows. 1) In a bucket mix the cleaning agent with some water (follow cleaning agent instructions) and pour into the urinal. This will carry the cleaning agent into the back of the trap and pipe connection. 2) No longer disturb the urinal in any way for the next 15 minutes until it automatically flushes. B) If it hasn t been flushed proceed as follows. 1) Hold the blade of a screwdriver into the water for 2 seconds and remove. Wait for 10 seconds to see if the urinal flushes. If not repeat the same procedure until it flushes. 2) In a bucket mix the cleaning agent with some water (follow cleaning agent instructions) and pour into the urinal. This will carry the cleaning agent into the back of the trap and pipe connection. 3) No longer disturb the urinal in any way for the next 15 minutes until it automatically flushes. 7.0 Overflow Protection: To avoid overflow in the case of a pipe blockage the urine sensing device will cease to activate further flushing once the urinal bowl has filled.

page 9 of 16 8.0 Installation Types: Use the following figures to provide installation guidance: Fig. 11 In-ceiling installation Fig 12 In-duct installation Fig 13 In-wall installation Fig. 11

page 10 of 16 8.0 Installation Types (Continued) Fig. 12

page 11 of 16 8.0 Installation Types (Continued) Fig. 13

page 12 of 16 9.0 System Description and Technical Specification 0.8 litre Active Urinal with Hideaway Smart Demand Operation and Urine Sensing Device The Sensor detects urine entering the urinal bowl and initiates a flush accordingly. The Controller is equipped with a flush time adjustment and program selector switches. Flush time can be selected depending on available dynamic pressure. The Program Selector switch allows the selection of the appropriate setting to maximise water conservation based on the expected usage as follows: Program 1 (Normal Mode-Factory setting) flushes after every use and will automatically switch to Saver Mode (1 flush every minute) when 4 users visit the urinal in less than 1 minute intervals no matter how many times used. 1 minute of non-use will reset the control unit back to Normal Mode. Janitors Flush activates after 48 hours of non-use. Program 2 (Eco Mode) flushes after every 3 rd user or 15 minutes, whichever is first. Janitors Flush activates after 48 hours of non-use. Overflow protection, avoids overflow in the case of a pipe blockage where the urine sensing device ceases to activate further flushing once the urinal bowl has filled. Self-diagnostic fault finding. Sensor is concealed to protect against vandlism. Operating voltage mains powered model: Operating voltage battery powered model: Power consumption: Output: Flushing time: Minimum dynamic pressure: Maximum dynamic pressure: Minimum connection pipe size: Minimum flowrate: 240 V AC 6V DC 0.3 W 6 V DC Selectable based on available dynamic pressure 275kPa 475kPa DN20 18 litres/minute (l/min)

page 13 of 16 10.0 Diagnostic Function: To assist in finding faults in the electronic components the controller is equipped with a diagnostic function. Follow the instructions below to activate this function. 1) Press and hold down Button 1 (flush time) for 10 to 20 seconds. While holding the button the LED will flash dimly, which is normal. 2) After 10 to 20 seconds release the button. 3) The LED will now flash in a bright sequence as outlined below. This LED flash sequence is consecutive and checks for 5 potential faults. Between each fault check the LED will switch off for a 5 second pause. Button 1 DIAGNOSTIC FUNCTION Battery Power check: One long flash = Battery OK OR Multiple flashes = Battery Power LOW Note: This check is for battery power controller checking only, not mains power Operating correctly CORRECTIVE ACTION RESPONSE Replace battery Problem fixed If problem cannot be resolved call 07 3875 2465 5 seconds pause Pause then, Capacitive Sensor check: One long flash = Sensor OK OR Multiple flashes = Capacitive Sensor not OK Operating correctly Ensure sensor cable is connected correctly at both plug connections. Re-start Urinal by turning power off and then on again after 30 seconds. Check red LED response as soon as power is switched on (see Commissioning). Look for 2 confirmation flushes to confirm urinal is functioning normally. Problem fixed If problem cannot be resolved call 07 3875 2465 for assistance 5 seconds pause Pause then, Temperature Sensor check: One long flash = Sensor OK OR Multiple flashes = Temperature Sensor not OK 5 seconds pause Pause then, Solenoid Valve check: One long flash = Solenoid Valve OK OR Multiple flashes = Solenoid Valve is not OK 5 seconds pause Pause then, indicates Average user statistics over the past 30 days. 1. Flash = less than 20 usages per day 2. Flashes = between 20 and 60 usages per day 3. Flashes = more than 60 usages per day Operating correctly Ensure sensor cable is connected correctly at both plug connections. Re-start Urinal by turning power off and then on again after 30 seconds. Check red LED response as soon as power is switched on (see Commissioning). Look for 2 confirmation flushes to confirm urinal is functioning normally. Problem fixed If problem cannot be resolved call 07 3875 2465 for assistance Operating correctly Ensure Solenoid Valve is connected. Re-start Urinal by turning power off and then on again after 30 seconds. Check red LED response as soon as power is switched on (see Commissioning). Look for 2 confirmation flushes to confirm urinal is functioning normally. Problem fixed If problem cannot be resolved call 07 3875 2465 for assistance Informative only, no action required. Pause then, Completion of Diagnostic Mode is followed by 2 confirmation flushes. In the event of power being disconnect or switched off, all user settings and functions are retained by the Flush Control Unit.

page 14 of 16 11.0 Trouble Shooting Guide: If you experience any technical issues refer to the Trouble Shooting Guide first. If the issue cannot be resolved, contact Tech- Support for phone assistance on free call 07 3875 2465. We are happy to assist you. Problem Symptom Remedy 1. Urinal will not flush. No power to control unit. Urine sensor does not activate urinal to flush. Ensure power supply is connected and switched on. Press Flush Time button to activate Diagnostic Function and follow steps (refer to manual section 10.0) 2. Water is spilling out near solenoid valve from air holes in vacuum breaker. 3. 40 seconds after use, the urinal still has not flushed. Flush valve orientation is incorrect. Water flow through urinal; is restricted. Flush valve contention to urinal is not long enough. The control unit is in Eco Mode. Rectify by mounting the valve vertically. Check waterways through urinal are clear. Raise the height of the flush valve kit assembly. Review step 5.0 flush program selection in Section 5.0. 4. Urinal flushes unexpectedly. Janitors Flush mode triggers an automatic hygiene flush after 2 days (48 hours) of non-use. 5. Poor flush performance. Strainer in the solenoid cartridge is blocked. Dynamic pressure has changed. 6. Urinal keeps flushing. Solenoid valve will not shut off, water flushes continuously. No action required Un-screw the solenoid cartridge and rinse out dirt out of the strainer (see Section 1 Maintenance of the Solenoid Cartridge). Check dynamic pressure and reset flush time step if required. Switch off power. Check Solenoid Valve is not fitted upside down. Correct direction is indicated by a directional arrow on valve body and labelling IN and OUT. Check also that the solenoid cable has been plugged in the correct way. 7. No response from battery powered controller. 8. After use of the urinal 4 short flushes are activated. 9. The urinal flushes at regular intervals without anybody triggering it. Red LED does not flash After use of the urinal, instead of the usual one flush 4 short flushes are activated. The urinal continues to flush at regular intervals. Restart the unit by switching the power on again. Remove battery from controller to check if battery is correctly fitted. Reinstall battery back into controller if still no response replace with new battery. Indicates that the battery is low. Replace the battery. Sensor trap defect replace sensor trap. 10. Urinal stopped flushing Possible struvite build up in the trap or pipe, pipe work blockages. Disconnect power to the flush system, wait for 10 seconds and re-connect. During the two commissioning flushes observe if water is draining slowly- if water is draining slowly, check for struvite build up in the ceramic, trap and pipe work clean out the ceramic, trap or pipework if required.

page 15 of 16 12.0 Maintenance of the Solenoid Cartridge: When performing maintenance on the flush valve or its components shut off the power and water supply and unplug the solenoid sealed connector cable. 1) Unscrew the solenoid cartridge (if required use a 17mm socket). 17mm socket Sealed connector cable 2) Rinse and clean the strainer fitted to the solenoid cartridge. 3) Before re-installing the solenoid cartridge lubricate the two O-Rings with a suitable tap O-Ring lubricant, Hydroseal tap lubricant or equivalent. O-Rings Note: Do not over-tighten. The max torque is 1Nm (hand-tight). Strainer

page 16 of 16 SPARE PARTS Picture Reece Code Product Description Part Number 9503303 URINAL CONTROL UNIT 240V 200.030 9503304 URINAL SENSOR TRAP (NO SEALS) 200.031 9503305 URINAL 240V TRANSFORMER 200.032 9503306 URINAL SENSOR EXT CABLE (2.65M) 200.033 9503307 URINAL INLET & OUTLET SEAL 200.034 9503309 URINAL SOLENOID CARTRIDGE 200.036 9503310 URINAL SOLENOID BODY 200.037 9503311 URINAL AIR BREAK 200.038 9503312 URINAL FLUSH VALVE SV-8 9503984 URINAL CONTROL BATTERY POWERED 200.040 9503985 URINAL BATTERY 6V CR P2 200.041 9502244 ACTVE URINAL GRATE WHITE CP-A267.80.03 9502245 ACTIVE URINAL INLET RUBBER 3170000294 9502246 ACTIVE URINAL WALL FIXING SET 3170000172