80PK-8 Type K Thermocouple Pipe Clamp Temperature Probe

Similar documents
80PK-2A Type K Immersion Probe

Temperature Probe, Battery (installed), Instruction Sheet, Quick Reference Card and Warranty Card.

Infrared Thermocouple Probe

Tachometer. English. Users Manual

i400s Calibration Information Introduction

Calibration Manual. Detachable Jaw True-rms Clamp Meter

P5510. Users Manual. Pneumatic Comparison Test Pump

Temperature Calibrator

P5514, P5514-V & P5514-EP Hydraulic Comparison Test Pump

5618B Platinum Resistance Thermometer User s Guide

Users Manual. MegOhmMeter

323/324/325 Clamp Meter


302+/303 Clamp Meter. Users Manual

5616 Platinum Resistance Thermometer User s Guide

365 Detachable Jaw True-rms Clamp Meter

Users Manual. Phase Rotation Indicator

373 Clamp Meter. Users Manual

1551A Ex/1552A Ex. Calibration Manual. Stik Thermometer

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

362 Clamp Meter. Users Manual

716 Pressure Calibrator

712 RTD Calibrator. Instruction Sheet. Introduction

362 Clamp Meter. Users Manual

i3000s/i2000 Flex AC Current Probe

PK-VLV-ABORT-100M, PK-VLV-ISO-40M, PK-VLV-ISO-100M

PK-8270-X/PK-8370-X. Lines and Fittings Kit. Instructions. Introduction. How to Contact Fluke Calibration

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

Visit us at

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

MegOhmMeter. Users Manual

233 True-rms Remote Display Digital Multimeter Safety Information

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Go to to register your product and find more information.

P5515, P5515-V, & P5515-EP Hydraulic Comparison Test Pump

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:

WIRING DIAGRAMS FOR BRIDGE CONTROL PANELS

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

HR-20P Pneumatically Controlled Pressure Regulator

11812 NE 116th Street TEL: Kirkland, WA USA FAX: INSTALLATION & SERVICE MANUAL AMFLOW PR7B Back Pressure Regulator

Users Manual. Airflow Meter

PY-11 Voltage & Continuity Tester

717 Series. Pressure Calibrators. Instruction Sheet. Introduction

HLY-1111 HEAD TEMPERATURE GAUGE

TMD90A Dual Input Digital Thermometer

INSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure

THERMOCOUPLE CALIBRATOR Mode KM-CAL-710

BEAMER Tilt Beam Sensor

SOIL RESISTIVITY TESTER

ODY-19-1 AIR PRESSURE GAUGE

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

Premium Waterfall Pump 1200 Gallons Per Hour

Effective June 1, 2013 This guide supersedes all previous versions

ODY-04-1 or ODY-04-2 rev. B WATER TEMPERATURE GAUGE

1000FLT. Users Manual. Fluorescent Light Tester

Cabling for power, control, and video must be run to the installation site before the mount is installed.

Premium Pond Pump 330 Gallons Per Hour

ODY-05-2 VOLTMETER FOR REMOTE MONITORING

User s Manual. Item no. 2561

SOLAR DASH CHARGING SYSTEM USER GUIDE

Power. On Your Terms.

HBC-20 - LED HIGH BAY

719 Series. Pressure Calibrator with Electric Pump. Product Overview (E)

ODY-10-1 rev. B FUEL PRESSURE GAUGE

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

Pro Shot Grease Dispense Valve

ODY-17-1 DIGITAL COMPASS DISPLAY

27 II/28 II. Digital Multimeters. Getting Started Manual. Specifications

BIN & SEN Annular Pitot Tube Flow Meter. Form: 10-PTT-UM (December 2012) Installation & Operation Manual

DWS404 DWS524 DWS654 DWS684 DWS694. DWS SERIES INSTALLATION/OWNER'S MANUAL Car Audio Speakers

OPERATION MANUAL MILLIAMP PROCESS CLAMPMETER MODEL - KM 071 LIST OF PRODUCTS

IR-500 Infrared Thermometer / Voltage Detector / Flashlight

NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL

Quick Start Guide Expansion Battery Pack UPS-OLEBPR-1 UPS-OLEBPR-2

Pump Package Conversion Kits

10 Year Limited Warranty

Installation Guide and Owner s Manual. For UTCIS-G and UTCIS-V Replacement Warm-up Regulator and Engine Management System

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

PVI 60KW, PVI 82KW, PVI 95KW

AIR VELOCITY METER ALNOR MODEL AVM410 AIRFLOW INSTRUMENTS MODEL TA410

Installation Manual Model 3800/3810

TIME-10 Process Control Stopwatch

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

Installation and Operation

EA / 10 / 50 Clamp Coil Adapter. Operation Manual. Version 1.00 April 2007 All product names are trademarks of their respective companies

Installation Instructions

INSTRUCTION BOOK FOR. Tensioned Advantage Deluxe Electrol

Installation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator

4-20mA DC PROCESS CLAMP METER

Operating Instructions for PAC800 Battery Charger

SUNTURA SOLAR TRACKER

OPERATING INSTRUCTIONS AND PARTS LIST BRIDGE DRIVE GEAR CASE

Transcription:

80PK-8 Type K Thermocouple Pipe Clamp Temperature Probe Instruction Sheet WARNING To avoid electrical shock, do not use this probe when voltages exceeding 24V ac or 60V dc are present. The probe is electrically connected to the output terminals. ATTENTION Pour éviter les risques d électrocution, ne pas utiliser cette sonde quand la tension est sepérieure à 24 V efficaces en courant alternatif ou 60 V en courant continu. La pointe de la sonde est reliée électriquement aux bornes de sorties. WARNUNG Um Elektroschock zu vermeiden, dürfen Sie den Meßstift nicht in der Anwesenheit von Spannungen über 24V Wechselstrom oder 60V Gleichstrom verwenden. Die Spitze des Meßstifts ist mit den Ausgangsanschlüssen elektrisch verbunden. ADVERTENCIA Para evitar descargas eléctricas, no use esta sonda cuando se apliquen voltajes que sobrepasen 24 V ca rcm o 60 V cc. La punta de la sonda está conectada eléctricamente a las terminales de salida. Introduction The 80PK-8 Type K Thermocouple Pipe Clamp Temperature Probe (Figure 1) is designed to reliably measure the temperature of pipes 1/4-inch (6 mm) to 1 3/8-inch (35 mm) in diameter, at temperatures between -29 C and 149 C (-20 F and 300 F), while retaining a long service life. February 1995 Rev. 1, 4/02 1995-2002 Fluke Corporation. All Rights Reserved. Printed in U.S.A. All product names are trademarks of their respective companies

Plunger Sensor V Notch Figure 1. 80PK-8 Pipe Clamp Temperature Probe Specifications Measurement Range: -29 C to 149 C (-20 F to 300 F) Accuracy: ±1.9 C (±.3.4 F). Surface measurement accuracy of ±1.9 C includes ±1.1 C variation in alloy plus probe contact and shunting uncertainty of ±0.8 C. Repeatability: ± 0.6 C (±1 F) Output: @ 25 C (77 F) = 1.00 mv (Reference junction at 0 C) Seebeck Coefficient: @ 25 C (77 F) = 40.50 µv / C Measurement Time (Time Constant): 0.5 seconds (5 time constants = 1 complete step change, i.e. 2.5 seconds) Maximum Voltage Rating: 24V ac rms, or 60V dc Sensor Material: Chromel-Alumel Cable Length: 40 inches (1 meter) Cable Isulation: Material: PVC Maximum Temperature: 105 C (220 F) Minimum Temperature: -29 C (20 F) Conductor: K Type AWG #24 stranded Probe Body: PBT Maximum temperature: 149 C (300 F) Minimum temperature: -29 C (20 F) Connector: Mini-thermocouple connector with 0.729 mm (0.312 in) pin spacing Media Limitations: Must be compatible with chromel, alumel, and PBT

Media Limitations: Must be compatible with chromel, alumel, and PBT Using the 80PK-8 to Measure Pipe Temperature 1. Using the miniature thermocouple connector, connect the 80PK-8 to a compatible Type K temperature measuring instrument. 2. Turn on the measuring instrument and select the appropriate range and scale. If you are using a temperature conversion module (the 80TK, for example), insert the module into the VΩ and COM inputs of the meter and select the mv dc function. 3. Using your thumb or the palm of your hand, press down on the plunger to open the jaws of the probe wide enough to easily encompass the pipe. Center the pipe on the V notch (see Figure 1) on the jaw of the probe and relax pressure on the plunger. 4. Read the temperature on the measuring instrument. When no heat or cold is applied to the sensor the measuring instrument should display the ambient temperature. If the instrument does not readout properly, refer to Troubleshooting. Measurment Considerations The 80PK-8 is designed to be compatible with any temperature-measuring instrument that accepts miniature Type K thermocouples with cold reference junction compensation. The accuracy of the temperature-measurement is a factor of the combined accuracy of the temperature measuring instrument and the 80PK-8. A lowering of the temperature at the sensor contact point is less likely (and response time is faster) on clean, polished, thermally conductive surfaces, then on surfaces with low thermal conductivity, such as plastic or rough, greasy surfaces. To obtain the best thermal contact and performance, the pipe must be centered in the V notch of the probe jaw. To get the most accurate temperature measurement, adjust the connection between the sensor and the pipe until you get the maximum or minimum temperature reading. When measuring the temperature of a rough surface, do not rotate the clamp. You might damage the sensor.

Troubleshooting When no heat or cold applied to the probe, the measuring instrument should display the ambient temperature. If the measuring instrument does not do so, try the following: 1. Verify that the temperature measuring instrument is designed to be used with Type K thermocouples. The instrument should have a yellow input connector and/or be marked with a K. 2. Check for an open circuit indicator on the measuring instrument. Some thermometers have a built in circuit to indicate if the connected probe is open. (All Fluke instruments have this feature.) Refer to instruments owners manual to see if this feature is available. If you suspect a broken connection, use an ohmmeter to check probe continuity from pin to pin. If the ohmmeter reads 10Ω, the probe is good. 3. Short the two input connectors to the instrument with a piece of wire. If the instrument is functioning properly it should display the ambient temperature. Cleaning Caution The handle and plug of the probe are made of materials that may deteriorate if exposed to some solvents on a long term basis. Using warm soapy water, brush the sensor lightly with a toothbrush. Excessive or abrasive brushing can damage sensor, and void the warranty. If necessary you can dip the brush (but not the sensor!) in rubbing alcohol.

LIMITED WARRANTY & LIMITATION OF LIABILITY Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is one year and begins on the date of shipment. Parts, product repairs and services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries or to any product which, in Fluke s opinion, has been misused, altered, neglected or damaged by accident or abnormal conditions of operation or handling. Fluke warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non-defective media. Fluke does not warrant that software will be error free or operate without interruption. Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price. Fluke reserves the right to invoice Buyer for importation costs of repair/replacement parts when product purchased in one country is submitted for repair in another country. Fluke s warranty obligation is limited, at Fluke s option, to refund of the purchase price, free of charge repair, or replacement of a defective product which is returned to a Fluke authorized service center within the warranty period. To obtain warranty service, contact your nearest Fluke authorized service center or send the product, with a description of the difficulty, postage and insurance prepaid (FOB Destination), to the nearest Fluke authorized service center. Fluke assumes no risk for damage in transit. Following warranty repair, the product will be returned to Buyer, transportation prepaid (FOB Destination). If Fluke determines that the failure was caused by misuse, alteration, accident or abnormal condition of operation or handling, Fluke will provide an estimate of repair costs and obtain authorization before commencing the work. Following repair, the product will be returned to the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges (FOB Shipping Point). THIS WARRANTY IS BUYER S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES. EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, WHETHER ARISING FROM BREACH OF WARRANTY OR BASED ON CONTRACT, TORT, RELIANCE OR ANY OTHER THEORY. Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court of competent jurisdiction, such holding will not effect the validity or enforceability of any other provision. 5/94

For application or operation assistance, or information on Fluke products, call: USA: 1-888-99-FLUKE (1-888-993-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 402-678-200 Japan: +81-3-3434-0181 Singapore: +65-738-5655 Anywhere in the world: +1-425-446-5500 Or, visit Fluke s Web site at www.fluke.com. Address correspondence to: Fluke Corporation Fluke EuropeB.V. P.O. Box 9090 P.O. Box 1186 Everett, WA 98206-9090 5602 BD Eindhoven, USA The Netherlands