kva kw kva kw Automatic syncronization and power sharing systems 50 C tropical type radiator Soundproof canopy Starter motor Length mm

Similar documents
kva kw kva kw 9,6 14 Automatic syncronization and power sharing systems 50 C tropical type radiator Soundproof canopy Starter motor

kva kw kva Dry Weigt Length Width kg K.U.N.Z. Handels-&Produktions GmbH

kva kw kva kw N/A K.U.N.Z. Handels-&Produktions GmbH

Voltage. kva kw kva kw

Dry Weigt Length Width kg mm mm. K.U.N.Z. Handels-&Produktions GmbH

Perkins 404D-22G diesel engine Newage/Stamford BCI184E alternator Standard Generator Features

CUKUROVA GENERATOR SYSTEMS

C U K U R O V A GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

Perkins 1006TAG2 diesel engine Newage/Stamford UCI274F alternator Standard Generator Features

CUKUROVA GENERATOR SYSTEMS

GNS 670 P. Stand-by power: 670 kva. Diesel Generating Sets, made for Europe. Standard Generator Features

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

GNS 400 V. Stand-by power: 400 kva. Diesel Generating Sets, made for Europe. Standard Generator Features

GNS 1100 P. Stand-by power: 1100 kva. Diesel Generating Sets, made for Europe. Standard Generator Features

GNS 630 V. Stand-by power: 630 kva. Diesel Generating Sets, made for Europe. Standard Generator Features

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

GNS 500 V. Stand-by power: 500 kva. Diesel Generating Sets, made for Europe

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

Volvo TAD733GE diesel engine Leroy Somer LSA 46.2 M5 alternator Standard Generator Features

Perkins 403D-15G diesel engine Newage/Stamford BCI164C alternator Standard Generator Features

Volvo TAD530GE diesel engine Leroy Somer LSA 44.2 VS3 alternator Standard Generator Features

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

Perkins 1103A-33G diesel engine Newage/Stamford BCI184G alternator Standard Generator Features

CUKUROVA GENERATOR SYSTEMS

Volvo TAD941GE diesel engine Leroy Somer LSA 46.2 VL12 alternator Standard Generator Features

Perkins 1006TG2A diesel engine Mecc Alte ECP34-2S/4 alternator Standard Generator Features

CUKUROVA GENERATOR SYSTEMS

LSC220S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 220 KW 176. Standby Power

204 KW / 254 KVA POWERED by

28 KW / 28 KVA POWERED by

CUKUROVA GENERATOR SYSTEMS

130 KW / 165 KVA POWERED by

55 KW / 70 KVA POWERED by

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power

64 KW / 80 KVA POWERED by

30 KW / 40 KVA POWERED by

Perkins 1104C-44TAG2 diesel engine Newage/Stamford UCI274C alternator Standard Generator Features

60 KW / 75 KVA. POWERED by. kva 75 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 70 Prime Power Factor 0.8 kw 55

350 KW / 438 KVA. POWERED by TP-V350-T1-60. kva 438 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 400 Prime Power Factor 0.

275 KW / 344 KVA. POWERED by TP-JD275-T3F-60. kva 313 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 224 Prime Power Factor 0.

CUKUROVA GENERATOR SYSTEMS

600 KW / 750 KVA POWERED by

1500 KW / 1875 KVA. POWERED by TP-MT1500-T2-60. kva 1875 Standby 3 Phase kw /208, 110/220, 120/240, 277/480

18 KW / 18 KVA POWERED by

150 KW / 195 KVA. POWERED by TP-JDR150-T3F-60. kva 194 Standby 3 Phase - Switchable kw /208, 110/220, 120/240, 277/480

Perkins 1006TAG diesel engine Newage/Stamford UCI274E alternator Standard Generator Features

2000 KW / 2500 KVA POWERED by

500 KW / 625 KVA POWERED by

BCI164C - Technical Data Sheet Winding 06

GMN - 22P 29/07/2016 GMN - 022P (ACP KPR) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

1020 KW / 1275 KVA. POWERED by TP-U1275-T2F-60. kva 1275 Standby 3 Phase - Switchable kw /208, 277/480. kva 1150 Prime Power Factor 0.

1000 KW / 1250 KVA POWERED by

PI144D - Technical Data Sheet

PI144J - Technical Data Sheet

400 Series 404A-22G1 ElectropaK 20.3 kwm / rpm

HCI 534E/544E - Technical Data Sheet

HCI 434E/444E - Technical Data Sheet

PI144D - Winding 17. Technical Data Sheet APPROVED DOCUMENT

Volvo TAD531GE diesel engine Newage/Stamford UCI274C alternator Standard Generator Features

UCDI224F - Technical Data Sheet

300 KW / 375 KVA POWERED by

UCI224C - Technical Data Sheet

UCDI274J - Technical Data Sheet

UCI274H - Technical Data Sheet Winding 06

UCI274H - Technical Data Sheet

PI044D - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

PI144G - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

PI044H - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

PI044F - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

PI044E - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

PI144E - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

PI144F - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

PI044G - Winding 06 APPROVED DOCUMENT. Technical Data Sheet

Perkins 4016TAG1A diesel engine Stamford PI734E alternator Standard Generator Features

PI144J - Winding 05 APPROVED DOCUMENT. Technical Data Sheet

UCI274C - Technical Data Sheet Winding 06

PI044D - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

640 KW / 800 KVA POWERED by

UCI224F - Technical Data Sheet

1800 KW / 2250 KVA POWERED by

UCDI224E - Technical Data Sheet

UCI274D - Technical Data Sheet

UCDI274K - Technical Data Sheet

UCI274D - Technical Data Sheet

UCI274G - Technical Data Sheet

BCI164D - Technical Data Sheet

BCI164B - Technical Data Sheet

Perkins TWG2A diesel engine Newage/Stamford PI734B alternator Standard Generator Features

Perkins 2506A-E15TAG2 diesel engine Newage/Stamford HCI544D alternator Standard Generator Features

UCDI274K - Technical Data Sheet

Perkins 2806A-E18TAG2 diesel engine Newage/Stamford HCI544F alternator Standard Generator Features

PI144K - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

Transcription:

Standby* Prime* Voltage kva kw kva kw 380-415 10 8 9 7,2 Ampere 13 Prime Rating Standby Rating Applicable for supplying continuous electrical power at variable load for unlimited hours. This model can supply 10% overload power for a period of 1 hour in 12 hours operation as it is defined in ISO 3046. Applicable for supplying continuous power ar variable load in the event of a utility power failure and overload is not allowed as it is defined in ISO 8528-3. Standard Generator Features Optional Features AMF, Automatic mains failure unit Automatic load transfer panel Heavy duty type, 3 cylinder, water cooled engine Automatic syncronization and power sharing systems 50 C tropical type radiator Soundproof canopy Starter motor Container type enclosers Lead acid battery Road trailer Charging alternator Job-site trailer Battery charge redressor Protection circuit breaker Heavy duty, brushless type alternator Air start Base frame with anti-vibration units Remote type radiator Industrial type silencers Base fuel tank Flexible exhaust compensator External type fuel tank Block water heater unit Automatic fuel transfer system Control panel with digital-automatic main control module Residential silencer Fan, fan drive, charging alternator drive and all rotating parts covered Radiator matrix covered by metal mesh against the mechanical damages Fabricated and welded steel base frame Anti-vibration mountings Engine and alternator manufacturer test reports Factory load, performance and function tests Dimensions & Weight Open Type KZS9PS Sound Attenuated KZS9PS Dry Weigt kg Length Width Height Tank Capacity L Dry Weigt Length Width Height Tank Capacity kg L KZS9PS Technical Data Sheet 120508 - Page1

Engine Technical Data Cooling System Manufacturer PERKINS Type Tropical, heavy duty type Model 403D-11G Ambient temperature, C 50 Type 4 cycle, water-cooled Engine&Radiator coolant capacity,l 5,2 Number of cylinders 3 Estimated cooling airflow reserve, kpa0,125 Cylinder arrangement Vertical in-line Thermostatically-controlled system with belt driven circulating Displacement, Liters 1.131,000 pump and pusher fan Bore X Stroke, 77 X 81 Mounted radiator piping and guards Compression Ratio 23:1 Combustion System Indirect injection Lubrication System Aspiration Natural Aspiration Rotation Anti-clockwise viewed on flywheel Type Pressurized Gross engine power, kwb 8,6 Capacity, Liters 4,9 BMEP gross, bar 6,10 Lub oil pressure (min), kpa 120 Combustion air flow, m³ / min 0,7 Wet sump with filler and dipstick Exhaust gas temp.(outlet), C 368 Spin-on full-flow lub oil filter Exhaust gas flow (after turbo),m³ / m1,66 Mean piston speed, m / s 4,1 Fuel System Fuel Consumption Type of injection system Indirect injection Fuel injector Pintle Nozzle Fuel injection Pump Cassette Type Delivery/hour at 1500rev/min, Lt 63 Governor type Mechanical Mechanically governed cassette type fuel injection pump Split element fuel filter liters per hour grams per kwh %110 Load %100 Load %75 Load %50 Load %110 Load %100 Load %75 Load %50 Load 2.9 L 2.6 L 2.0 L 1.5 L 261 g/kwh 252 g/kwh 258 g/kwh 286 g/kwh Electrical System Alternator 12 Volt, 55 Amp Starter motor (DC) 12 Volt Standby kw Prime kw Model Starter motor power 2 kw Gross Net Gross Net 12 volt starter motor and 12 volt 15 amp alternator with DC output Oil pressure and coolant temperature switches 403D-11G 9,5 11,8 8,6 10,75 12 volt shut-off solenoid energised to run Glow plug cold start aid and heater/starter switch KZS9PS Technical Data Sheet 120508 - Page2

Alternator Technical Data Optional Equipment Manufacturer STAMFORD Upgrade to Excitation Boost System (EBS) Model PI044E Quadrature Droop kit for Parallel Operation Type 4-Poles, Rotating Field, Brushless Anti Condensation Heaters Prime power at rated voltage, kva 10 Efficiency, % 80,5 Power factor 0.8 Terminals&Terminal Box Phase 3 Frequency, Hz 50 Standard generators are 3-phase reconnectable with 12 Speed, Rpm 1500 ends brought out to the terminals, which are mounted at the Voltage, V 400 non-drive end of the generator. Dedicated single phase Excitation Self excited generators are also available. A sheet steel terminal box Stator windings 2/3 Pitch factor contains provides ample space for the customers' wiring Regulation AVR, Auto Voltage Regulator and gland arrangements. Alternative terminal boxes are Voltage Regulator AS480 Voltage Regulation, % ± 1 R.F.I Suppression BS EN 61000-6-2,BS EN 61000-6-4 VDE0875G, VDE 0875N Shaft&Keys Waveform distortion No Load <1.5% Non distorting All generator rotors are dynamically balanced to better than balanced linearload <5.0% BS6861:Part 1 Grade 2.5 for minimum vibration in Rotor Dynamic balanced operation. Two bearing generators are balanced with a half key. Overspeed, Rpm 2250 Short circuit current < 300% TIF Less than 50 Insulation / Impregnation Insultion class H Construction Single bearing, direct coupled The insulation system is class 'H'. Coupling Flexible All wound components are impregnated with materials and Stator winding Double layer concentric processes designed specifically to provide the high build Connection WYE required for static windings and the high mechanical Protection class IP23 strength required for rotating components. Winding&Electrical Performance Standards All generator stators are wound to 2/3 pitch.this eliminates triplen Stamford industrial generators meet the requirements of harmonics on the voltage waveform and is found to be the optimum BS EN 60034 and the relevant section of other design for trouble-free supply of non-linear loads.the 2/3 pitch international standards such as BS5000, VDE 0530, design avoid sexcessive neutral currents sometimes seen with NEMA MG1-32, IEC34, CSA C22.2-100, AS1359. higher winding pitches, when in parallel with the mains.a fully connected damper winding reduces oscillations during paralelling. This winding, with the 2/3 pitch and carefully selected pole and tooth designs, ensures very low waveform distortion. Quaility Assurance Standby Prime Model Generators are manufactured using production procedures having a quaility kva kw kva kw assurance level to BS EN ISO 9001. PI044E 11 8,8 10 8 KZS9PS Technical Data Sheet 120508 - Page3

Deepsea 7320 Control System Description Features Deepsea 7320 is an Auto Mains(Utility) Failure Control module. The module is used to monitor a mains supply and automaticlly start a standby generator set. The module can also monitor an extensive number of engine parameters and it can display warnings, shutdown and engine status information on the back-lit LCD screen, illuminated LEDs, remote PC and via SMS text alerts. Selected timers and alarms can be altered by the user from the front panel. Alterations to the system are made using the 810 interface and a PC and it also provides real time diagnostic facilities Specification DC SUPPLY Continuous Voltage Rating: 8 V to 35 V Maximum Operating Current: 340 ma at 12 V, 160 ma at 24 V Maximum Standby Current: 160 ma at 12 V, 80 ma at 24 V Charge Fail/Excitation Range: 0 V to 35 V 4-Line back-lit LCD text display and five key menu navigation LED and LCD alarm indication 9 configurable inputs and 8 configurable outputs Configurable timers, alarms and event log (250) Fuel usage monitor and low fuel alarms Charge alternator failure alarm Manual speed and manual fuel pump control Engine exerciser and ''Protections disabled'' feature kw overload protection Power monitoring ( kw, h, kv Ar, kv A h, kv Ar h) Load switching (load shedding and duy load outputs) Automatic load transfer and unbalanced load protection Independent Earth Fault trip Support for up to three remote display units and USB connectivity Configurable display languages Remote SCADA monitoring User selectable RS232 and RS485 counications SMS messaging ( external modem required) Additional display screens to help with modem diagnostics MAINS(UTILITY) & GENERATOR Voltage Range: 15 V - 333 V AC (L-N) Alarm Channels Frequency Range: 3,5 Hz to 75 Hz Under/over generator voltage OUTPUTS Over-current Output A (Fuel): 15 A DC at supply voltage Under/over generator frequency Output B (Start): 15 A DC at supply voltage Under/over speed Output C & D : 8 A 250 V (Volt free) Charge fail Emergency stop Input Functions display on LCD Low oil pressure High engine temperature Generator Volts Volts L1-N, L2-N, L3-N Fail to start Generator Volts Volts L1-L2, L2-L3, L3-L1 Low/high DC battery voltage Generator Amps Amps L1, L2, L3 Reverse power Generator Frequency Hz Generator phase rotation error Mains Volts Volts L1-N, L2-N, L3-N Generator short-circuit protection Mains Volts Mains Frequency Volts L1-L2, L2-L3, L3-L1 Hz Loss of speed sensing signal Mains out of limits Engine Speed RPM Plant Battery Volts Volts Optional Input Functions Engine Hours Run Hour Generator total power kva L1, L2, L3,total Engine Oil pressure kpa Generator total power kw L1, L2, L3,total Fuel level % Generator power factor Cosφ L1, L2, L3,total Engine Temperature C KZS9PS Technical Data Sheet 120508 - Page4

Model Codes and General Information Kunz Diesel Generator KZ S 9 P S Alternator Make-Stamford Engine Make-Perkins Prime Rating - kva Stationary type KUNZ diesel generator Perkins 400 Series Diesel Engine Newage / Stamford Alternator 403D 11 G P I 04 4 E Core Length Number of poles Genset engine 1.1 liters 400 Series, 3 cylinder Shaft Height in cm Industrial Generator type KZS9PS Technical Data Sheet 120508 - Page5