PCS 100 SYSTEM INSTALLATION INSTRUCTIONS

Similar documents
PCS-250 System Installation Instructions

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

Installation Instructions

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

Installation Instructions

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

1100 Series Piston Type Differential Pressure Gauges

General Description. Product Specification. Document Digital Temperature Interlock

USERS GUIDE LO-21U LOCKOUT RELAY

OPERATION MANUAL Common for All models Bobbin Sensor (Weft End Detection) DP150 - L2 BP150 - L2-12V BP150 - L2-24V (PNP/NPN)

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

PRODUCT INFORMATION BULLETIN

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

3 Phase Smart Controller

Installation, Operation and Maintenance Manual

Senior Swing Control Box. Table of Contents

Model 2300DL Installation Guide

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Plasma Display Electric Pop-Up Lift (PUL)

RoHS-Compliant. Watertight, Dust-Resistant Motors FPW Series

Operation and Installation Manual

BOX A3 TEST REL. DATE R.T. Check and Approval

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Quarter Master Series 94 Actuator

Safety Standards. Model Number:

Model 2300JL Installation Guide

OPERATIONS MANUAL M-520. Please take the time to read these instructions before starting to use the scales. Page 1

INQUIRY: HYROBOTICS CORP SAM LEE ( ) 5988 MID RIVER MALL DR. ST.CHARLES MO TEL : FAX :

Combined Ventilation Controller RVWS-T-224HA

TPAK Series COOLANT PUMP

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

BAPI-Com, Two Wire Multifunction Sensor BA/BS4SCOM Temperature/Humidity Sensor Installation and Operating Instructions

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

Type 2000 Transducer Product Instructions

COUNTIS E22 Three-phase energy meter Direct - 80 A

DEEP SEA ELECTRONICS PLC

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (0-10VDC Input Version)

Operating Instructions. Angle Seat Control Valve. Type 7020

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3

Solid State Relays contactor with Integrated Fuse Type RGC1F

USERS GUIDE BODYGUARD III SMR PRESENCE SENSOR

Ionizer. Discharge time: 0.3 seconds. Series IZS31. Ion balance control by an autobalance sensor CAT.EUS100-68A-UK. Without sensor.

CBM-105FN/FP Circuit Board

ECONOMISER SERIES E2T USER MANUAL

Filtered PWM Speed Control for Permanent Magnet DC Motors

TX³ RCCBs 2P up to 100 A

Starting System DS-102 Series 200. Elmatik AS P.O.Box 309 NO-3471, Slemmestad T F

INSTALLATION MANUAL ACL 5500 COMBUSTION SAFETY CONTROLLER

BAPI-Com, Two Wire Multifunction Sensor with Setpoint Slider (BA/BS4SCOM) Temperature/Humidity Sensor

DC Variable Speed Drive Panel

5600 Series Power Operator Installation and Instruction Manual

702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS

Table 1: 2-pin Terminal Block J1 Functional description of BSD-02LH Module Pin # Pin Description Table 2: 10-pin Header J2 Pin # Pin Description

Electrical Options Booklet. Table of Contents

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

AC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave

Inductive Proximity Sensor

User Manual. 1. Introduction

Series IZS31. RoHS compliant

Te 803 Electronic Controller. Service, Operation & Technical Information Manual

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE

SAFE AND SECURE EXTREME R MOTOR OWNER'S MANUAL MODEL PRO-FDG FOR TECHNICAL SUPPORT PLEASE CALL 1-(855) OPERATOR SERIAL#

Installation Sheet January, 2016 Supersedes February, 2013

Signet Pressure Transmitter

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

SAFEDGE INSTALLATION & USER MANUAL PRESSURE SENSITIVE SAFETY EDGE SYSTEM READ THIS MANUAL IN FULL BEFORE INSTALLATION

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Application Engineering

GCU-10. Automatic Engine Control Unit Operators Manual

EG3002. Electronic Engine Governor Controller User Manual

CB-005N Circuit Board

EZS. Motorized Linear Slides. Series. RoHS-Compliant

UZK24.071, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS

The Battery is a client module in the Cabinet Control. It is a backup/ups module which

DX³ RCCBs - ID 4P up to 100 A

Programmable Logic Controller. Mat Nor Mohamad

BR230 MOTORIZED VIP. OPERATION and MAINTENANCE MANUAL

DEEP SEA ELECTRONICS PLC

B100S - Super Swing. Instruction Manual. Document number: B100S-C Release: V4.0 Date: May 08,2009

1332 TROUBLESHOOTING GUIDE. Remarks: If this function is not appropriate for the application, it can be eliminated by turning off DSWl, switch 3.

224-EN WIRELESS CONTROLLER INSTALLATION & INTERFACE GUIDE. Guide No. 224-EN USING AS REPLACEMENT CONTROLLER

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

Model 124 Filter Minder & Model 124

Thunder Power Tarp Kit Operation. Dual Arm Curb Side Stowing Single Arm Curb Side Stowing Flex Arm Curb Side Stowing.

Application Engineering

ThinkTop DeviceNetTM VDC DeviceNet is a Trademark of the Open DeviceNet Vendor Association, Inc. (ODVA).

Names and Functions of Driver Parts

ENGINE PROTECTION BOARD PDM1

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Standard cylinders DDPC, with measured-value transducer DADE

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Three-Phase Soft Starters

INSTRUCTIONS. DO NOT CONNECT TO MAINS POWER ( V AC).

Electric Trolling Motor

1.0 Features and Description

5700 Series Power Operator Hinge (Pull) Side Mount Installation and Instruction ASSA Manual ABLOY

Tandem Fix 40 Ship to Shore Spreader

Transcription:

PCS 00 SYSTEM INSTALLATION INSTRUCTIONS PCS - 00 + - POWER 4VDC CW TIME LO NL 4 5 6 ON C&K SDA06 CCW HI RL WHITE BROWN BLACK NC L NC L ON C&K SDA04 4 NO M NO M RESET START 5V 4V COM (0) BLUE SCU-00 Made in the USA

4 5 6 ON C&K SDA04 4 Page PCS - 00 SPECIFICATIONS 55.0 mm 45.0 mm SCU00 4VDC Power Supply Input: 4VDC, 50mA Operating Voltage: 4VDC Relay Maxium Outputs: Current: A, 50mA 50VAC general use Operating Temp: 0-55 C Ambient Temp: 55 C Housing Mat: Polycarb.UL94V + - POWER 4VDC CW TIME LO NL ON C&K SDA06 CCW HI RL WHITE BROWN BLACK NC L NC L NO M NO M START 5V 4V RESET COM (0) BLUE SCU-00 75.0 mm DC ON V.ADJ -V +V 4VDC 0.6A INPUT 50/60Hz 00-40 VAC 0.A L N 75.0 mm Input Power: 0-40VAC Output Voltage: 4VDC Output Power: 5W Operating Temp: 0-55 C Wiring Terminal Terminals: Mat: 8-4AWG Polycarb.UL94V stranded copper wire only, Max. Wire Size: AWG 7 lb/in Torque. One wire per terminal. Mounting: 5mm DIN Rail Mounting: 5mm DIN Rail Optional power supply required for 0-40 VAC operation Housing Matl.: Terminal Matl.: Polycarb UL94V Polycarb UL94V Mounting: 5mm DIN Rail 0.0 mm 95.0 mm IND. CONT. EQ. 5BY 40MM ( 5.50" ) 0MM (0.9") 40MM (.57 ) CS-6000 0MM ( 4.7" ) 7MM (.06" ) NE-40-F (Optional) 5.0M ( 6.0' ) 7.5MM (.475" ) 8MM (.0" ) NE-40 PCS-00 SC-0500 SA-5000

Page. General Use / Description The Positive Contact System consists of two main components; a Positive Contact Sensor ( PCS ) and a Sensor Control Unit ( SCU ).The control unit is mounted in the machine electrical cabinet, while the sensor is mounted in close proximity to the tool which is to be monitored. The sensor monitors the tool presence by light physical contact of the tool tip with the sensing needle assembly. If the tool is present at the specific station, the needle will contact the tool tip and return to its starting position. The machine cycle will then be allowed to continue. If the tool is broken, the needle will swing past the broken tool to its complete swing angle stop. This condition will immediately be interpreted as a fault condition, and the control unit sends the appropriate stop output to the machine control.. Determine The Mounting Position Determine where you wish to mount the PCS sensor. This will depend on the space available and the tooling configuration of your machine. The variables are listed below. a) Preference for clockwise ( CW ) or counter clockwise (CCW) swing direction. ø8.50 mm b) Swing angle (see fig. ) The most common swing angle selection is 45º to 90º. ~80º of swing is available in either swing direction. Ø 4.00 mm Figure 7.00mm d) The standard sensing needle length is shown in figure. You may use either a longer ( up to 8 ) or shorten the standard sensing needle to your application. ( Figure ) 45º CW swing angle. c) You will need to fabricate a mounting bracket that will hold the sensor in place. If you will mount the sensor using the clamping collar provided, drill holes in the bracket per figure. Figure 40.0 mm Note: If a straight sensing needle does not suit your needs, the sensing needle may be bent into any desired configuration.

Page. Mount the Clamping Collar to the bracket The clamping collar holds the PCS sensor body and allows for attachment to the mounting bracket fabricated by the customer according to the application. Below is a typical mounting example. Mounting Bracket Clamping collar (provided) Nut for mounting screw (provided) Mounting screw (provided) Sensor assembly 4. Install the mounting bracket according to your application 5. Loosen and remove the sensing needle assembly Loosen the.5mm set screw B on the sensing needle assembly and slide the assembly off the sensor. ( Figure 5 ) 6. Set swing direction and angle The PCS sensor features a 80º adjustable swing angle in either a CW or CCW direction. The sensor can be preset at the factory to your specifications. If you did not specify a swing angle in your order, the sensor is set to a 90º CW swing. CW or CCW is established by looking at the sensing needle straight on (looking at the adjusting ring). The ring is divided into 45º increments. ( See fig. 6 ) A B A G A = CW 45º Fig. 5 B = CW 90º Fig. 6 B F C = CW 5º D = CW/CCW80º E = CCW 5º C D E F = CCW 90º G = CCW 45º

Page 4 To change the swing angle or swing direction loosen the set screw A until the knurled adjusting ring B can be manually rotated. Note that the knurled ring has a red mark. Turn the knurled ring to the desired swing angle in either CW or CCW field. If you are changing from CW to CCW or from CCW to CW, always move away from the zero zone and PAST the 80º mark, (~5 ). Once you have passed the 80º mark, the sensor will operate in the CW or CCW field it is in. The knurled ring will not move through the zero zone. Once the desired swing angle and direction are set, tighten set screw A. The red mark on the adjusting ring will not rotate through this zone. A B When moving from CW to CCW, rotate the adjusting ring in this direction. When moving from CCW to CW, rotate the adjusting ring in this direction. 7. Mount the sensor in the bracket. Slip the PCS sensor into and through the bracket assembly. Connect the power cable to the sensor and then rotate the sensor in the bracket so the connector points in the desired direction. Be sure the cable is properly positioned to avoid any interference with the machine operation. Note: If the cable needs to be repositioned while attached to the sensor, rotate the entire sensor to avoid damage to the connector. Fig. 7.60mm Reinstall the sensing needle assembly but do not fasten it. Move the sensor body forward or back so the needle will contact the tool according to the sketch in figure 7. Once the sensing needle assembly is properly located, tighten the clamping collar fastener to secure the sensor to the bracket. Remove the sensing needle assembly. Alternative Mounting Examples

Page 5 8. Install the Sensor Control Unit. (SCU) Install the SCU-00 in the electrical cabinet according to the installation instructions. If you have specified a supply voltage of 5V an additional power supply has been included. The power supply is not required for 4VDC operation. 9. Set CW or CCW selector switch on the SCU. If you have selected a CW or CCW swing direction on the sensing head, flip the selector switch on the SCU to the corresponding setting. 0. Supply power to the SCU. Once power has been supplied to the SCU, the sensor will rotate to its starting position.. Re-install the sensing needle assembly. Re-install and fasten the sensing needle assembly so that the sensing needle will contact the tool anywhere between the starting position of the needle and the end position of the needle. Start Position The tool or object to be monitored must be located within this zone. End Position Example illustrates a 90º CW swing direction. Check your installation. Cycle the PCS sensor. If the sensing needle assembly is installed properly, the needle will contact the tool tip and return to its starting position. The green LED on the SCU will illuminate. Now, remove the tool and initiate another start input. The needle should travel through its full swing angle to the end stop. This simulates a broken tool condition. The red LED on the SCU should be illuminated.

Page 6 SCU Terminal Descriptions Terminals & : The SCU operates with 4VDC, note that terminal is + and terminal is -. This unit requires a minimum supply of 50 ma. When powering the SCU with an existing 4VDC power supply, confirm that the supply is capable of additional output capacity to power the SCU. Terminals & 4: Not used. Terminals 5, 6, 7 & 8: Sensor cable connection, as indicated. The preferred method is to connect the cable directly from the sensor to the SCU. If the SCU and sensor need to be connected via external junction box, avoid wiring near electromagnetic or high current devices. DO NOT connect the braided shield in the supplied sensor cable to the machine ground! 4 5 6 7 8 + - POWER 4VDC CW TIME LO NL 4 5 6 9 0 ON C&K SDA06 CCW HI RL WHITE BROWN NC L NC L ON C&K SDA04 4 NO M NO M RESET BLACK START 5V 4V 4 5 COM (0) BLUE SCU-00 6 Terminals 9 & 0: are dry contacts ( internal relay ) capable of switching A @ 50 VAC. The contact operation can be configured eliminating peripheral devices for interfacing the SCU. ( see Relay Control Switches, page 7 ) Terminals & : are dry contacts ( internal relay ) capable of switching A @ 50 VAC. The contact operation can be configured eliminating peripheral devices for interfacing the SCU. ( see Relay Control Switches, page 7 ) Terminal : Is used to reset the SCU after a fault condition has been detected. The required input is + 4VDC for a minimum of 00mS. (OPTIONAL) Terminals 4, 5 & 6 are used to activate the checking sequence when required in your application. T-6 is the common for either a 5VAC start signal (T-4 ) or a 4VDC start signal ( T-5 ). The SCU recognizes a change of state in the circuit to activate the checking sequence. A minimum duration of 00mS is required regardless of the of the signal utilized, ( HI LO HI ) or ( LO HI LO ). The Start Signal can also be used as a RESET function. After the error condition has been corrected, (replace broken tool), applying a Start Signal will cause the sensor to begin the checking sequence; touching and confirming that the tool has been replaced, in-turn resetting the Control Unit. Certain solid state devices, although in their off ( LO ) state, may output a small amount of current. Depending on the operating characteristics of these devices, the SCU may not recognize a change of state. If this condition occurs in your application you may need to incorporate an external relay to activate the checking sequence.

Sensor Control Unit Switches Please Note: Unless otherwise specified when ordered, the SCU-00 Control Unit has been preset at the factory with a CW direction, # Time Setting and a HI Rate. Page 7 LED (See Relay Control Switches Below) The LED will illuminate at power on. When a start signal is initiated the LED will momentarily turn off. If a good condition has been detected the LED will again illuminate momentarily. LED (See Relay Control Switches Below) When a fault or broken tool condition is detected the LED will illuminate momentarily or until the unit is reset if relay is set to Latch. CW / CCW Switch This switch selects the rotation of the sensor. This setting MUST correspond with the knurled adjustment on the sensor. LO / HI Switch Selects the rate at which the sensor swings. HI is the correct setting for nearly all applications. LO rate is a slower swing rate generally used only for micro tool detection. NOTE: The V-seal in the swing arm assembly provides additional protection against contaminants and should not be removed in most applications. The V-seal may however restrict the sensors motion when the swing rate is set on LO. If your application does not allow HI rate operation, you may remove the V- seal from the swing arm assembly to determine if this solves the problem. Time Switches These switches control the amount of time the sensor rotates during the scanning sequence. Since it takes a greater amount of time to swing the sensing needle 80º than 90º, a greater amount of time needs to be set. If the sensor will not reach its end or fault position with the tool removed simply set more time. NOTE: If a TIME selection has not been made the Control Unit operates at a default LO-LO setting used for very small micro-drill applications only. (See LO/HI Switch settings above with regards to V-seal in Swing Arm Assembly). NL/RL Switch Selects the units operational mode and logic. NL= Normal logic RL= Reverse logic (free space monitoring) CW TIME LO NL CCW HI RL 4 5 6 Relay Control Switches These switches are used to set the condition and the operation of the SCU s internal relays. These features have been added for increased interface flexibility Relay Contact Configuration NO= Normally open NC= Normally closed NC L NC 4 L Relay Contact Configuration NO= Normally open NC= Normally closed Relay Operation M= Momentary L= Latch NO MNO M Relay Operation M= Momentary L= Latch

4 5 6 4 4 5 6 4 Page 8 SCU Installation Guide ESD/EMF PROTECTION: The SCU is a microprocessor based unit. When mounting the SCU in the machines electrical cabinet avoid placing it near sources which might produce ESD (electro static discharge), or EMF ( electro magnetic frequencies ), such as large motor starters or high current devices. ESD/EMF may interfere with the units operation. The cable supplied with the sensor is fully shielded. The preferred installation method is to connect the sensor cable directly to the SCU. If your installation requires connecting the sensor to the SCU via a junction box/terminal strip, avoid wiring near EMF sources. The distance of the sensor connection to the SCU should not exceed 50m (65 ). Special length shielded cables are available upon request. Below is a basic wiring diagram for 4VDC and 5VAC machine control voltages. For any questions or installation assistance call -855-866-59. BASIC WIRING DIAGRAM SCU-00/4VDC BASIC WIRING DIAGRAM SCU-00/00-40VAC 4VDC SENSOR COMMON SENSOR 5 VAC COMMON + - POWER 4VDC CW TIME LO NL CCW HI RL WHITE BROWN BLACK NC L NC L NO M NO M START 5V 4V RESET COM (0) BLUE SCU-00 DC ON -V +V 4VDC 0.6A V.ADJ INPUT 50/60Hz 00-40 VAC 0.A L N 5W + - POWER 4VDC CW TIME LO NL CCW HI RL WHITE BROWN BLACK NC L NC L NO M NO M START 5V 4V RESET COM (0) BLUE SCU-00 RESET PB RESET PB START SW START SW A CONTACT TO PLC INPUT, SWITCH ETC. A CONTACT TO PLC INPUT, SWITCH ETC. TO PLC INPUT, SWITCH ETC. TO PLC INPUT, SWITCH ETC.

PCS-00 System Trouble Shooting Guide Page 9 Please refer to the section that best describes the problem you are having. Determine if you can answer YES to all of the questions. If not, attempt to correct the condition. If at anytime you have questions, please contact our service department at -855-TOOL-9 (855-866-59). SYSTEM (Red and green lights are illuminated simultaneously.) Has a time been selected via the dip switches on the SCU-00? Is the PCS-00 set in the same direction as the CW/CCW switch on the SCU-00? Is the swing angle setting on the PCS-00 offset at least 5º from the 0º and 80º marks? Is the PCS-00 returning to its start position at the end of each cycle? Color coded wires of cable should be attached to the correct terminals on the SCU-00 Cable should be screwed tight to the PCS-00 The inside of the PCS-00 connector should be dry Manually move the sensing needle away from the start position. Does the sensing needle return to the start position on its own? Is there approximately 4.VDC across the blue and black terminals on the SCU-00? (The PCS-00 must remain connected to the SCU-00 for this measurement.) Is there 4VDC across the Power terminals on the SCU-00? If not, see No Power to SCU-00 SCU-00 WILL NOT START (Lights remain steady, PCS-00 does not swing and SCU-00 gives no output when a start signal is applied.) Is the start signal being applied to the correct terminals? Terminals 5 & 6 are for a 4VDC start signal. Terminals 4 & 6 are for a 5VAC start signal. Is the correct start signal being applied? The signal can be AC or DC voltage. Polarity does not matter. The SCU-00 can be started with a low, high, low sequence or a high, low, high sequence. The SCU- 00 will always start on the transition from low to high. Is the high condition either 4V or 5V? Is the low condition 0 V? The low condition must be 0 V. If the low condition is not an absolute 0 V, the SCU-00 may not recognize it. Is each change in condition being held for at least 00ms? In an environment with a lot of electrical noise, (ie: large motors or motor starters), the high, low, high sequence will block any noise from accidentally starting the SCU-00. Is the start signal being applied after the SCU-00 has completely finished its last cycle? SIGNAL WHEN TOOL IS. Is the PCS-00 sensor set to swing in the correct direction to contact the tool? Is the tool within the PCS-00's swing angle? The sensing needle of the PCS-00 should be set to swing at least 5º past the tool for the best results. The sensing needle's tip should extend over the tool's centerline. The sensing needle should contact the tool at least.6mm from the tool's tip. Is the sensing needle supplied by Allora being used? Is the clamping collar tight on the PCS-00? Is the sensing needle assembly tight on the PCS-00? Is the set screw for the swing angle adjustment ring on the PCS-00 tight? Is the PCS-00 connected properly? Color coded wires of cable should be attached to the correct terminals on the SCU-00. Cable should be screwed tight to the PCS-00 connector. The inside of the PCS-00 connector should be dry.

PCS-00 System Trouble Shooting Guide (cont.) Page 0 NO SIGNAL WHEN TOOL IS BREN (Given a fault condition, SCU-00 continues to give output.) Is there enough time set on the SCU-00 for the PCS-00 to reach its full swing angle? Have any objects that could obstruct the swing angle of the PCS-00 been removed? Is the clamping collar tight on the PCS-00? Is the swing arm assembly tight on the PCS-00? Is the set screw for the swing angle adjustment ring on the PCS-00 tight? With power disconnected from PCS-00, can the sensing needle be moved freely back and forth without any binding? Look for metal chips which may be packed around the seals on the PCS-00 or between the PCS-00 and the swing arm assembly. Look for large chip "bird's nests' that may be getting caught on the PCS-00. Is the PCS-00 set in the same direction as the CW/CCW switch on the SCU-00? Is the swing angle setting on the PCS-00 offset at least 5º from the 0º and 80º marks? Is the PCS-00 connected properly? Color coded wires of cable should be attached to the correct terminals on the SCU-00. Cable should be screwed tight to the PCS-00's connector. The inside of the PCS-00 connector should be dry. The V-seal in the swing arm assembly provides additional protection against contaminants and should not be removed in most applications. The V-seal may however restrict the sensors motion when the swing rate is set on LO. If your application does not allow HI rate operation, you may remove the V-seal from the swing arm assembly to determine if this solves the problem. NO POWER TO SCU-00 (No lights illuminated when SCU-00 is powered up and no power to PCS-00.) If 5VAC, is the power supply supplied by Allora being used? Is there a clean 4VDC being supplied to the Power terminals on the SCU-00? Is there no more than two SCU-00's running on one power supply? Is there 0-0VAC being supplied to the power supply? Is the power supply sending 4VDC to the power in terminals on the SCU-00? NO FROM SCU-00 Does the PCS-00 swing when the SCU-00 is given a start signal? If not, see SCU-00 Will Not Start Is the red or green light illuminated and at its normal intensity? If not, see No Power to SCU-00 The outputs from the SCU-00 are momentary (500 ms.) Can your application use an output of this duration? The outputs from the SCU-00 can be set to latch. (See Installation Instructions) With tool present, give the SCU-00 a start signal. Do contacts & close (or open momentarily depending on face plate settings.)? This same check can be done for the fault output by removing the tool and checking across contacts 9 & 0. NO POWER TO PCS-00 Are one or more lights on the SCU-00 illuminated? If not, see No Power to SCU-00 Is the PCS-00 connected properly? Color coded wires of cable should be attached tot he correct terminals on the SCU-00. Cable should be screwed tight to the PCS-00 connector. The inside of the PCS-00 connector should be dry. Manually move the sensing needle away from the start position. Does the sensing needle return to the start position on its own? Is there approximately 4.VDC across the blue and black terminals on the SCU-00? (The PCS-00 must remain connected to SCU-00 for this measurement.) Is there 4VDC across the power terminals on the SCU-00? If not, see No Power to SCU-00

PCS-00 rev.00 Positive Contact Control Units conform with the EEC directive EMC 89/6/EEC as amended by 9//EEC and 9/68/EEC. In compliance with the directive, the EC Declaration of Conformity and related Technical Documentation is maintained at the following address for inspection by the appropriate official RoHS Compliant Positive Contact Hazardous Materials All Positive Contact products and packaging are manufactured with RoHS compliant materials. They are free of Bromide Halogens (PBB, PBDE), Mercury, Cadmium, and Chrome 6+. All Positive Contact products are Lead Free. All Positive Contact products comply with current EU environmental standards, including directive amendments regarding the use of perfluorooctane sulfonates, (PFOS). All Positive Contact products and packaging are free of any material containing Asbestos. All Positive Contact foam packaging is free of CFC s, HCFC s or HFC s. The foam and its ash is non-toxic, landfill safe and recyclable.