Differential Pressure Sensors

Similar documents
Differential Pressure Sensors

Pressure sensor for liquid and gaseous media QBE620-P...

Differential Pressure Sensors

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Differential Pressure Sensors

Pressure Sensors. for liquid and gaseous media

Differential pressure sensor

Differential Pressure Switch QBM81-

Differential pressure switch for monitoring air pressure in HVAC systems.

Modulating control valve PN16 with magnetic actuator

Differential Pressure Switch QBM81-

Actuators for small valves

Control of cutting-oil emulsion for industrial grinding machines. Applications for CHW and LPHW systems, see data sheet CA1N4454E.

Modulating control valve PN16 with magnetic actuator

Electric actuators for small valves

Modulating control valve PN16

Use. Functions. OpenAir TM. Rotary version, modulating, with spring return, AC 24 V

Sensor systems. Type Differential pressure transducer. For the differential pressure recording and control in combination with EASYLAB.

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Modulating control valves with magnetic actuators, PN 16

Air damper actuators

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Pressure transmitter for industrial applications Type MBS 4510

JUMO MIDAS S05 Pressure transmitter Type

Actuators for Fire Protection Dampers

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Electromotoric Actuators

Air damper actuators

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

Electrical Actuators

Pressure transmitters for industrial applications Type MBS 4510

Beck. The differential pressure transmitter for air with IP65

Actuators for Fire and Smoke Protection Dampers

DCT 533. Industrial Pressure Transmitter with IO-Link Interface. Stainless Steel Sensor

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

Pressure transmitters for heavy duty applications MBS 3200 and 3250

Pressure Transmitter

Modulating control valves with magnetic actuator PN 16

Pressure transmitter for industrial applications Type MBS 4500

Electromotoric actuators

Pressure transducer DMU 01K Compact version

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Pressure transmitter for general purpose Type MBS 1700 and MBS 1750

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Modulating Control Valve PN 16 with Magnetic Actuator

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

Butterfly valves, PN6, PN10, PN16

High temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250

FlowCon Energy FIT System

SATRON VTe pressure transmitter

JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

JUMO MIDAS Pressure transmitter

GDB..3..1A GLB..3..1A

Modulating control valves with magnetic actuators, PN 16

Pressure Transmitters

Figure 1: WPR2 Dimensions and Hardware

Butterfly valves PN6, PN10, PN16

Pressure transmitter for marine applications Type MBS 5100 and MBS 5150

2-position electric actuators with Ball valves VBZ ½...11/4

HUMIDITY / TEMPERATURE TRANSMITTER

Alterostat M2S 104/114. Applications. Features

Selectable ranges and an LCD are a technician s best friend, that s why we make them standard on every dry media differential pressure sensor!

Data Sheet P1A Pressure Sensor

Relative and absolute pressure transmitter type 691

Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250

CTE7000 / CTU7000 Series Miniature pressure transmitters

Differential Pressure and Flow meters Accessories for the Media Series

CTE9000 / CTU9000 Series OEM pressure transmitters for industrial media

OEM Pressure Transmitters

Pressure transmitter for marine applications MBS 3100 and MBS 3150

Differential-Pressure Flow Meter

Output signal active note. Measuring range rel. pressure. Electrical Data Power supply DC V, ±10%, 1.1 W

Actuators for Fire and Smoke Protection Dampers

Pressure transmitters for heavy duty applications Type MBS 3250

JUMO MIDAS S07 MA. OEM Pressure Transmitter - Maritime Approved. Applications. Brief description. Special features.

Ministat M/MS 624/634. Applications. Features

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Electromotoric actuators

Actuators for Fire and Smoke Protection Dampers

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES

Pressure Transmitter. Pressure transmitter with compact design Model EDC-K. Electronic. Applications. Special Features.

Industrial Pressure Transmitters

SSI Technologies Application Note PS-AN2 MediaSensor Absolute & Gage Pressure Transducers & Transmitters Product Overview

JUMO dtrans p20 DELTA

Modulating control valve with magnetic actuator PN16

P1A Pressure Sensor. Description. Features. Applications MAIN FEATURES

Paddle-wheel flow controller for On/Off control

ETP80. Electronic Transmitter for Pressure, Differential Pressure and Level

JUMO dtrans p35. Pressure Sensor with IO-Link. Application. Brief description. Customer benefits. Special features

Paddle-wheel flow controller for On/Off control

Relative and absolute pressure transmitter type 507

Pressure transmitter for marine applications MBS 33M

VMP43... Two-port and three-port seat valves PN16. Siemens Building Technologies Landis & Staefa Division

Type A-10 General Purpose Pressure Transmitter

Transcription:

1 920 1920P01 Differential Pressure Sensors for neutral and mildly corrosive liquids and gases QBE63-DP Differential pressure sensor, suitable for gases and liquids, for the measurement of positive and negative pressures and pressure differentials in HVAC systems Hall-effect transducer technology Highly resistant to positive pressure Simple, robust construction for highly reliable operation For neutral and mildly corrosive liquids and gases Supply voltage AC 24 V or DC 2030 V DC 010 V output signal Female-threaded G 1 /8" connection Use The QBE63-DP differential pressure sensors are particularly suitable for use in HVAC systems for continuous monitoring of the level or flow rate of neutral or mildly corrosive gases or liquids The pressure being monitored acts on a measuring system comprising a diaphragm, permanent magnet and Hall-effect transducer The measured pressure is converted electronically into a linear DC 0 10 V output signal Types Type Pressure range QBE63-DP01 0 100 mbar 0 10 kpa QBE63-DP02 0 200 mbar 0 20 kpa QBE63-DP05 0 500 mbar 0 50 kpa QBE63-DP1 0 1 bar 0 100 kpa CA1N1920E 06062005 Siemens Building Technologies Landis & Staefa Division

Ordering and delivery When ordering, please specify the quantity, product name and type code Example: 1 differential pressure sensor, type QBE63-DP05 and 2 mounting kits, type AQB511 A suitable fixing bracket is supplied with the sensor Any accessories required must be ordered separately Compatibility The QBE63-DP differential pressure sensors can be used in conjunction with all devices or systems capable of processing the DC 010 V output signal Technology The pressure to be monitored acts on an EPDM diaphragm which deflects a spring As a result of the pressure and consequent movement of the diaphragm, a permanent magnet attached to the diaphragm changes its position in relation to the Hall-effect transducer on the outside of the pressure housing The transducer delivers an electrical signal proportional to the magnetic field This signal is linearised, temperaturecompensated and amplified by the built-in electronics Cross-section 920072 6 5 4 3 p2 7 2 p1 1 Key: 1) Pressure housing (measuring chamber) 2) Diaphragm and spring 3) Permanent magnet 4) Hall-effect transducer with measuring electronics 5) Cover 6) Cable entry with PG9 gland 7) Purging points p1 G 1 /8" threaded connection for higher pressure or lower vacuum p2 G 1 /8" threaded connection for lower pressure or higher vacuum Mechanical design The QBE63DP differential pressure sensors comprise: Plastic housing with Pg 9 cable gland Pressure casing with diaphragm and spring Printed circuit board with Hall-effect transducer Fixing bracket 2/6 Siemens Building Technologies Differential pressure sensors QBM63-P CA1N1920E HVAC Products 06062005

Accessories AQB511 Mounting kit comprising: 2 brass thread adapters, 2 x G 1 /8", male 2 copper seal, 1 /8" 1 m copper capillary with retaining nuts at each end, G 1 /8" female 1 thread adapter, G 1 /8" female to G 1 /2" female, with 1 copper seal, 1 /2" Thread adapter, G 1 /8" female to R 1 /2" male Mounting instructions (no 35757) The components of the AQB51 mounting kit are supplied by SERTO, but the kit must be ordered from HVAC Products (SBT) Other mounting arrangements can be ordered directly from the SERTO range 80364a Mounting instructions Mounting instructions are enclosed with the differential pressure sensor The QBE63-DP sensors can be connected directly with G 1 /8" or R 1 /8" screwed fittings Special precautions must be taken on site when mounting the sensors, to ensure airtight screw connections Recommended measures: Important note Use standard T-fittings or drill and de-bur measuring holes, each 5 mm diameter, for the pressure tapping points (A) An isolating bypass (5) can be fitted to avoid overloading the pressure sensor on one side while making adjustments For inspection purposes, measuring circuits can be fitted with a measuring-t at the sensor head Mounting for use with liquids: Always mount the sensor lower than the pressure measuring points Mount on a vibration-free surface Always evacuate the system ø max 5 mm 90 Supply Return + A A 1 2 5 2 1 4 80357 4 4 3 P1 P2 3 + QBE-DP Key: A Measuring holes 1 Isolating valves (SERTO SO 7100-6 GREY and, if required, screw-on base SERTO SO 09904-4-8) 2 T-joints (SERTO SO 03000-1/8) 3 Connection pieces (from mounting kit AQB 511) 4 Copper pipes (from mounting kit AQB 511) 5 Isolating bypass Siemens Building Technologies Differential pressure sensors QBM63-P CA1N1920E HVAC Products 06062005 3/6

Technical data Electrical interface Power supply Max voltage tolerance Power consumption Current consumption Output signal Low voltage (SELV, PELV) AC 24 V, 50/60 Hz or DC 2030 V +15 / 10 % <1 VA 35 ma DC 010 V, short-circuit-proof and proof against polarity reversal 10 kω Working resistance Product data Differential pressure range Operating range, see Types Measuring element Hall-effect transducer Measuring accuracy <±10 % FS (FS = Full Scale) Hysteresis <±15 % FS Linearity <±15 % FS Temperature drift 008 % FS / K (20 C in relation to zero point) Overload capacity 10 bar (sensor range up to 200 mbar) 20 bar (sensor range from 500 mbar) Burst pressure 30 bar Dynamic response: Response time Load alternation <10 ms <10 Hz Suitable media Admissible temperature of medium Air or mildly corrosive gases and liquids 10+80 C Maintenance No maintenance required Protective data Protection standard IP 65 to IEC 529 (with cover fitted) Combustion class Cover UL 94 HB Connections Connection terminals 3 screw-terminals, 15 mm 2 Cable entry Pg 9 cable gland Pressure connections Female-threaded G1/8" Mounting Mounting bracket For mounting in ducts, on walls or ceilings and in control panels Orientation Any (factory-calibrated with pressure connections at bottom) When used with liquids: purging points at top Environmental conditions Perm ambient temperature Operation Storage/Transport 25 +60 C (electronics) 40 +80 C Perm ambient humidity <90 % r h (non-condensing) Standards Electromagnetic compatibility Immunity to Emissions to EN 50 082-2 EN 50 081-1, EN 50 081-2 conformity to EMC directive 89/336/EWG Materials Pressure casing Nickel-plated brass Cover Cable gland Plastic (ABS without fibre-glass) Polystyrol Diaphragm EPDM (ethylene propylene rubber) Mounting bracket Galvanised steel Mounting kit AQB511 See "Accessories" Weight Including packaging 086 kg 4/6 Siemens Building Technologies Differential pressure sensors QBM63-P CA1N1920E HVAC Products 06062005

Connection terminals G U M + 80358 0 Supply voltage AC 24 V or DC 20 30 V DC 0 10 V output signal (reference point GND) GND Dimensions Fixing bracket 72 43 20 920073 22 G 1/8 94 47 10 ø 5,2 11 18,8 ø 65 G 1/8 46 40 60 63 Dimensions in mm Siemens Building Technologies Differential pressure sensors QBM63-P CA1N1920E HVAC Products 06062005 5/6

6/6 2005 Siemens Switzerland Ltd Subject to changes Siemens Building Technologies Differential pressure sensors QBM63-P CA1N1920E HVAC Products 06062005