Pressure Gauge. Fluid admitted Pressure indication range Accuracy Service temperature range Cap. Resin body GPC (1)

Similar documents
Related vacuum products

DPS280 / DVS280 Series

Vacuum Switch with LED display

Pressure Switch with Super slim LED Display

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display

Vacuum pump system type

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

VAS VAS VACUUM SWITCH SPECIFICATIONS. DIMENSIONS (mm)

2-Color Display High-Precision Digital Pressure Switch

Simple Pressure Level Setting. The threshold level is able to adjust simply. Just set the pointer suitable for the displayed pressure level.

VSG Series Features Descriptions VSG VSG VSG Descriptions Supply valve Descriptions Vacuum filter

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES

2-Color Display High-Precision Digital Pressure Switch

Construction diagram Semiconductor transducer Silicone oil. Stainless steel SUS316 pressure port Hastelloy C diaphragm.

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

SERIES LED Display Digital Pressure Sensor. Clearly Visible LED Display with 3 1 /2 Digits

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series)

Super fast 1 ms Convenient intermediate cable with connector A total of 10 head variations

SERIES LED Display Digital Pressure Sensor. Clearly Visible LED Display with 3 1 /2 Digits

Series 10-ZSE40A(F)/10-ISE40A

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

SECTION 6 VACUSTAT, PRESSURE SENSORS, VACUUM SENSORS, & FILTERS

9.8 mm. Digital Pressure Switch. 3-step setting. RoHScompliant. Series ZSE10(F)/ISE10. Vertical mounting space reduced to approx.! Reduced in depth!

PG-30 PRESSURE GAUGES P G R - N FEATURES MODEL NUMBER DESIGNATION

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2

Digital Pressure Sensor with Auto-reference Function. Example of air-leak test. Threshold level. Reference pressure. Reference pressure

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

Quick-fitting Type Mechanical Valve. Mechanical Valve

2 Window comparator mode. Hysteresis Hysteresis

DP5/DPH. Head Separated Digital Pressure Sensor. 1/1000 Second High-Speed Response. The advantage of the fastest response in the industry SERIES

Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

PG-30 PRESSURE GAUGES P G R - N MODEL NUMBER DESIGNATION

Remote Type Pressure Sensors Pressure Sensor Controllers

Differential Pressure Sensor

2-Color Display Digital Pressure Switch

Low Differential Pressure Sensor ±1% F.S.

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch 25 M ISE30 01 ZSE M. How to Order. For positive pressure

Model Pressure range ON/OFF output Linear output

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Digital Pressure Sensor

2-Color Display Digital Pressure Switch

Light Coupling Series

Vacuum Generator VN. Vacuum level

2-Color Display Digital Flow Switch

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue.


80g. 10.5mm. Width: Weight: Complex Vacuum Generator with Lightweight, Compact Body and High Vacuum Cycle Vacuum Generator VX Series

2-Color Display Digital Pressure Switch

Series PSE560 Pressure Sensor For General Fluids... 90

External vacuum controller

Digital display Pressure range ON/OFF output Linear output Model

Digital Pressure Switch

Series ISA. Air Catch Sensor. For Detection of Work Presence

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

Portable pressure calibrator, Wally Box III Model CPH7600

Model Pressure range ON/OFF output Linear output

Compact Flow Rate Sensor. RAPIFLOW FSM3 Series Resin Body Type. Diversified High Performance. High performance. User-friendly. Compatible CC-1235A 1

11 kinds of display multiplier Full 3-digit red LED P Z N V S T I. 1 ~ 5 V 4 ~ 20 ma 1 ~ 5 V 4 ~ 20 ma 1 ~ 5 V 4 ~ 20 ma 1 ~ 5 V 4 ~ 20 ma

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant

DPC-100 Series INSTRUCTION MANUAL WIRING I/O CIRCUIT DIAGRAMS PART DESCRIPTION

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

Vacuum Equipment. Application. Series

Series PSE100. Controller PSE10. How to Order. Controller Specifications Option. Output specifications. Mounting

Pressure Sensors. Section C. Pneumatic. Sensors.

Minimal Fitting Series

Electro-Pneumatic Regulator / Electronic Vacuum Regulator

ISE6B. Series ZSE6B. Digital Pressure Switch. With Backlight. (For vacuum) (For positive pressure) For General Purpose Fluids

PSG5xx ATM to Medium Vacuum Gauge

Nozzle diameter: ø0.5, ø0.7, ø1.0, ø1.2. Features

Main Block Series. Concentrated Branching Joint for Assembly. Assembling Manifold Blocks for Concentrated Branching

Electro-Pneumatic Regulator/Electronic Vacuum Regulator

Electro-Pneumatic Regulator Electronic Vacuum Regulator

Pressure Transmitters

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

(Actual size) 2 switches 10 switches. Push Adjust to the set-value by the or button.

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Tube Fitting PP Series

Electronic Pressure Switch EDS 3000

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

Tube Fitting Brass Series

4 Note 1) Value for communications type. (PROFIBUS DP)

JUMO MIDAS S05 Pressure transmitter Type

10 PSE53 0 M5. Port size. M5 x 0.8 ø6 reducer 1/4-inch reducer. the cable at the time of shipment. 10-PSE to -101 kpa

Miniature Regulator Series ARJ310

Digital Pressure Switch

Check Valve AP64 P.149. Vacuum Generator Vacuum Generator Module Vacuum Generator Module AP7 & 70 AP71 AP72. Flow Switch Flow Switch (For high flow)

Series ITV0000. Compact Electro-pneumatic Regulator ITV N. IITV00 02 n. How to Order F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Electro-Pneumatic Regulator Electronic Vacuum Regulator. Series Model Set pressure range Port size to 0.1MPa to 0.5MPa to 0.

Electronic pressure switch for air

Models SPG5A and SPG6A

2-colour Display High Precision Digital Pressure Switch

Sensor specifications Model no.

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

JUMO dtrans p20 DELTA

Transcription:

Pressure Gauge Feature The compact-size pressure gauges can be installed in small spaces. With the built-in tube fitting type, tube connection is the only necessary step before pressure indication. Graphical representation Fluid admitted Pressure indication range Accuracy Service temperature range ap Material Metalic body Resin body Air 0~113.psi 0 ~ 0.MPa ±5%(Full span) 32~140 F 0~0 Acryl Nickel-plated brass PT(GPU, GPM) Designation (Example) GP (1) M5 (2) (3) ode Size ode Size (1)Type (2)Type,thread size Tube dia (mm) 4 φ4mm φmm φmm Unified fine thread American standard Taper pipe thread U10 N1 N2 10-32UNF NPT1/ NPT1/4 in. size Metric thread Taper pipe thread 5/32 1/4 5/1 M5 01 02 φ5/32 φ1/4 φ5/1 M5 0.(mm) R1/ R1/4 (3)Hexagon flat-to-flat specification U: Hexagon flat-to-flat inch spec. (NPT) No code: Hexagon flat-to-flat mm spec.! Detailed Safety Instructions efore using the PISO device, be sure to read the "Safety Instructions", "ommon Safety Instructions for Products isted in This Manual" on pages 23~24 and "ommon Safety Instructions for ontrollers" on pages 17~1. 1. 2.! aution The gauge orientation on the GPU and GPM types can not be changed by using a tool applied to the hexagon part. Direct turning of the gauge cap may damage the gauge or render the indication inaccurate. The gauge accuracy of Pressure Gauge is ±5%FS (full span). To confirm the accuracy, check with another gauge. GP Pressure gauge Straight φ A code GP -M5 GP -01 GP -02 A R M5 0. R1/ R1/4 A 3 11 1.5 21 24 13.5 1 1.5 R Metric thread type 23

GPU Union Straight φ GPU 4-4 GPU - GPU - Tube dia. 4 φp E1 10 13 1.5 20 22 E2 24.5 2 2 12.5.5 20 GPM A GPM 4 GPM GPM Tube dia. 4 M M12 1 M14 1 M1 1 A 1 14 39 42.5 45.5 1 φp 1 19 22 1.5 G 5 5 H 14 19 12.5 1 21.5 φ φp H M G GPJ GPJ 4 GPJ GPJ 4 3 3 35 23 25 21 1.5 9.5 12.5 φ 2-φP E2 2-2-E1 2- ulkhead type Nipple type 239

Pneumatic Vacuum Switch To enhance visibility, an ED display is used for the vacuum switch. ED displays are used for set-up pressure and impression pressure. Two types of vacuum switch equipped with two-point output and analog output are provided. The application determining which should be used. In respect to wiring, a connector system has been chosen for ease of layout. Three pipe connection methods are offered: one-touch, M5 metric female screw, and direct connection. The application will determine which method is the most appropriate. Output detection accuracy is enhanced by the use of electronic switches. NPN opencollector output PNP opencollector output With 2-point output switch With analog output switch efore using the PISO device, be sure to read the "Safety Instructions", "ommon Safety Instructions for Products isted in This Manual" on page to and "ommon Safety Instructions for ontrol Series" on page 59 and "ommon Safety Instructions for ED Digital Pressure Sensors, Digital Pressur Sensors & Pressure Sensors" on page 77. 1. The cable can be connected to or disconnected from the connector. ut avoid connection and disconnection unless it is absolutely necessary, for it will put burdens on the cable or the board. 1. Although performance will not be affected even when pressure of around 0.5MPa (72.5psi) is applied, avoid continued application of pressure greater than 0.2MPa (29psi) during vacuum breaking. Prolonged application of such pressure may possibly cause damage to the sensors. 2. To set pressure and differential response, turn trimmer slightly with a screw driver within the prescribed range of rotation. Trying to adjust trimmer rotation by applying excessive force may possibly damage to the trimmer and base board. 3. As for power, use a stable direct current. 4. Insert a surge voltage absorption circuit in relays connected to output terminals and power source terminals (relays, electromagnetic valves, etc.). Do not use an electric current exceeding 0mA. 5. Ground the FG terminal when unit power souces, such as a switching power source unit, are used.. Do not short-circuit output terminals (black with a gray lead wire) and other terminals. 7. Avoid strong impacts and excessive force to the sensor body.. To install the sensor, use the specially prepared M2.5 screw. Tighten it to the recommended torque. 9. Fluid used must be kept in a pristine state. VUS21-4 VUS21 - VUS21 - VUS21 -F 79 VUS21 -M5

Sensor Heads, Separate display type Pressure sensor and Vacuum switch Small-sized 24.5-mm pressure sensors (width: 10mm height, 10mm total length). "Union," "Nipple," and "Male screw" are prepared. Use of an analog output type and indicator (SED30-series) has made a separate display system possible. Our small-sized pressure sensors can handle "positive pressure," "negative pressure" and "ompound pressure". oncerning output, a total of six different specifications are prepared. Standard cable length is 3m. A large 31.4mm square size indicator is used, realizing a high level of visibility with its large-sized ED display. All settings can be made using just three push buttons. For indication units, you can choose from among 11 different types. Two different kinds of output methods are offered - analog output and switch output. Four (4) different kinds of installation stays are available depending on installation form. - for installation in the rear, on a flat surface, panel-buried, and for protection of display components. Fluid admitted Pressure detection Power requirements Power consumption Service pressure range Proof pressure Storage temperature range Operating temperature range Operating hummidity range Protective structure No. of pressure setting Switch output Display of action Switch output Differential response Operating accuracy Response Pressure setting range SEU 11 series VUS 11 series VUS 11-R series Air, inert gas Proliferated semiconductor pressure switch D10. ~ 30V (ripples included) 20mA or less (D24V at no-load) 0 ~ 0psi (0 ~ 1MPa) 0 ~ -30in. Hg (-100 ~ 0kPa) 21psi (1.5MPa) 29psi (200kPa) 9 ~ -30in. Hg (-100 ~ 300kPa) 7psi (00kPa) -4 ~ F (-20 ~ 70 ) (Atomospheric pressure, hummidity less than 0%RH) 32 ~ 140 F (0 ~ 0 ) (No freezing) 35 ~ 5%RH (No freezing) IE standard IP40 equiv. 1 NPN Open collector output: 30V 0mA max. Residual voltage 0.V max. N.O. (red ED lights up when set pressure exceeded) Fixed (2%F.S. max.) ±3%F.S. max. (at Ta=25 /77 F) Approx. 1msec 0 ~ 0psi (0 ~ 1MPa) 0 ~ -30in. Hg (-100 ~ 0kPa) 9 ~ -30in. Hg (-100 ~ 300kPa) Fluid admitted Pressure detection Power requirements Power consumption Service pressure range Proof pressure Storage temperature range Operating temperature range Operating hummidity range Protective structure Output voltage Zero-point voltage Analog output Max. rated pressure voltage Output current inearity SEU 11 series VUS 11 series VUS 11-R series Air, inert gas Proliferated semiconductor pressure switch D10. ~ 30V (ripples included) 20mA or less (D24V at no-load) 0 ~ 0psi (0 ~ 1MPa) 0 ~ -30in. Hg (-100 ~ 0kPa) 21psi (1.5MPa) 29psi (200kPa) 9 ~ -30in. Hg (-100 ~ 300kPa) 7psi (00kPa) -4 ~ F (-20 ~ 70 ) (Atomospheric pressure, hummidity less than 0%RH) 32 ~ 140 F (0 ~ 0 ) (No freezing) 35 ~ 5%RH (No freezing) IE standard IP40 equiv. 1 ~ 5V 1 ±0.1V 5 ±0.1V 1mA max. (oad Resistance 5kΩ min.) ±0.5%F.S. max. 0

1 SED-30 Power requirements D10. ~ 30V onsumption current 50mA max. (supply voltage: D10V when a 2-point switch is turned ON for output) Storage temperature range -4 ~ F (-20 ~ 70 ) (Atomospheric pressure, hummidity less than 0%RH) Operating temperature range 32 ~ 122 F (0 ~ 50 ) (No freezing) Operating hummidity range 35 ~ 5%RH (No freezing) Protective structure IE standard IP40 equiv. No. of indications 4 times/sec Response Variable with a digital filter, about 5, 25, 250, 2500msec Indication accuracy ±1%F.S. Temperature characteristics ±0.5F.S. (32 ~ 122 F (0 ~ 50 ), reference temperature: 25 /77 F) Monitoring function Pressure indication method Switch output Analog output "0" adjustment function Resolution Pressure indication element ode indication element Rated pressure indication range Number of output point Switch output method Switch capacity Residual voltage Pressure setting method Pressure setting range Operational indication Repetitiveness Temperature characteristics Response Setting differential responses Protection against overloads Output voltage Output current Sensor input specifications Voltage input signal Pressure sensors used Units of pressure Magnification (Unit) Pressure range setting code 1 (kpa) 0.0102 (kgf/cm 2 ) 10.2 (gf/cm 2 ) 7.501 (mmhg) 102 (mmh2o) Rated pressure 0.01 (bar) indication range 10 (mbar) (P ~ PH) 0.145 (psi) 0.000145 (kpsi) 0.001 (MPa) 0.2953 (In.Hg) Analog output mode indicated eyond indicated numbers of digits eyond detection range Detection of output overloads Monitoring of adjustment errore "9 9 9" flashes "- - -" flashes (rated pressure: 110% or more) "E - 1" flashes/overloads detected, output indication lamp flashes Panel switch-operated pressure indication (zero clear) Monitors "0" adjustment operation when residual pressure is impressed beyond (10%F.S.). "Error Warning E-2" flashes (cancelled using a panel switch) 1 digit 3-digit 7-segmented ED (character height: mm), colored red ED lamp (illuminates at "minus", colored red) Pressure indication units and rated pressure ranges are selected via the panel switches listed in the table given below. 2-point outputs (SW1, Sw2) NPN Open collector D30V 100mA max. 1.2V max. (with load current at 100mA) Using a panel switch -999 ~ 999 count (decimal points are to conform to the range of rated voltage as given in the tabulated specifications). Two EDs light up (SW1: green, SW2: red, when output is switched ON) ±0.2%F.S. ±1count ±0.5F.S. (32 ~ 122 F (0 ~ 50 ), reference temperature: 25 /77 F) an be adjusted by setting digital filters, 5, 25, 250, 2500msec 0 ~ 300 counts (canbe adjusted via a panel switch) 2-point output switches (SW1, SW2) are switched OFF (overload current: "200mA or beyond" or "beyond 200mA") 1 ~ 5V 1mA (oad resistance: 5kΩ min.) 1 ±0.1 ~ 5 ±0.1V VUS11- A -12P 0.0 ~ -99.9 0.00 ~ -1.02 0 ~ (-999) 0 ~ -750 0.00 ~ -1.02 0 ~ -999 0.0 ~ -14.5 0.0 ~ -29.5 3 VUS11- AR SEU11- A kpa 32r -100 ~ 300-1.02 ~ 3.0-1.00 ~ 3.00-14.5 ~ 43.5-0.10 ~ 0.30-29.5 ~ -.5 1 13P 0 ~ 999 0.00 ~ (9.99) 0.0 ~ 9.99 0 ~ 145 0.00 ~ 1.00 0 ~ 295 2 Positive pressure sensor Negative pressure sensor ø4mm nipple ømm nipple M5 0. male screw R1/ male screw ø4mm quick-fitting joint (fitted with an in-line installation holder) ømm quick-fitting joint (fitted with an in-line installation holder) Analog output ompound pressure type analog output NPN open collector output ompound pressure type NPN open collector output *ompound pressure type ( R) is only accepted when "VUS11" is selected. Rear angles (rear angles, two M3 4 male screws) Flat surface angles (two M3 4 male screws) Holder cover set (a panel holder cover, a panel holder) Panel holder set (a panel cover, a panel holder and panel stopper) Holder stopper set (a panel holder and panel stopper) efore using the PISO device, be sure to read the "Safety Instructions", "ommon Safety Instructions for Products isted in This Manual" on page to and "ommon Safety Instructions for ontrol Series" on page 59 and "ommon Safety Instructions for ED Digital Pressure Sensors, Digital Pressur Sensors & Pressure Sensors" on page 77. 1. For power, use stable direct currents. 2. Insert surge-absorbing circuits into relays, valves, etc. Do not arbitrarily use these units at currents that exceed rated levels. 3. When using unit power sources, such as switching power sources, be sure to ground their FG terminals. 4. Take the utmost care to avoid short-circuitting the output terminal with other terminals. 5. Do not apply excessive loads to pressure sensors. Subjecting them to excessive loads can damage them.. Do not wire nozzles and other components in a way that will impress them with noises, etc. Do not use them in any arbitrary manner, either. Doing so can cause malfunctions. 7. When conducting pressure adjustments for units fitted with switch output sensors, use small screwdrivers (included). Do not apply excessive force to these screwdrivers, and turn them slowly. Applying excessive force may damage the units.. Our indicator (SED-30) is not constructed to be drip- or dust-proof. As such, do not use indicators that have been exposed to water or oil and/or dust. 9. For the SED-30 indicator s sensor heads, use either a VUS 11 A. or an SEU 11 A type head. Using different specifications with these sensor heads will not achieve the required level of accuracy. 10. Do not pull or bend vacuum switch lead wires excessively. Doing so may result in lead wires being snapped off and connector components broken.

SEU11-4US SEU11-US VUS11-4US VUS11-US VUS11-4USR VUS11-USR SEU11-4S SEU11-S VUS11-4S VUS11-S VUS11-4SR VUS11-SR SEU11-M5S SEU11-01S VUS11-M5S VUS11-01S VUS11-M5SR VUS11-01SR SEU11-4UA SEU11-UA VUS11-4UA VUS11-UA VUS11-4UAR VUS11-UAR SEU11-4A SEU11-A VUS11-4A VUS11-A VUS11-4AR VUS11-AR SEU11-M5A SEU11-01A VUS11-M5A VUS11-01A VUS11-M5AR VUS11-01AR SED-30 APG-003 APG-004 APG-007 APG-011 APG-012 *It is equipped with two screws *It is equipped with two screws for fixing the sensor. for fixing the sensor. 2