CM5-11 A-R-G-E-AQQE F-A-A-N

Similar documents
CM1-6 A-R-I-E-AQQE F-A-A-N

CM25-1 A-R-G-E-AQQE C-A-A-N

Set 2 Mini Pust APB50B

CM10-3 A-R-A-E-AVBE F-A-A-N

CM5-9 A-R-I-E-AQQE F-A-A-N

CM15-1 A-R-I-V-AQQV C-A-A-N

CM3-11 A-R-G-E-AQQE F-A-A-N

CM3-5 A-R-I-E-AQQE F-A-A-N

CM5-5 A-R-A-E-AVBE F-A-A-N

CM1-8 A-R-I-E-AQQE F-A-A-N

CM10-3 A-R-G-V-AQQV F-A-A-N

CM10-1 A-R-A-E-AQQE F-A-A-N

CM1-2 A-R-A-E-AQQE F-A-A-N

Company name: GRUDNFOS VisMin Created by: Kimmboy Ancis Phone: Date: 13/03/2017

CM5-5 A-R-G-V-AQQV F-A-A-N

CM3-6 A-R-G-E-AQQE C-A-A-N

CME1-4 A-R-I-E-AQQE S-A-D-N

CM1-5 S-R-I-E-AQQE C-A-A-N

CM1-3 S-R-I-E-AQQE C-A-A-N

CM5-6 A-R-A-E-AQQE C-A-A-N

CM5-5 A-R-A-E-AVBE C-A-A-N

CME5-5 A-R-I-E-AQQE S-A-D-N

Company name: GRUDNFOS VisMin Created by: Kimmboy Ancis Phone: Date: 13/03/2017

CR45-10 A-F-A-E-HQQE 3x400/ HZ

TP /2-A-F-A-BQQE 400D 50HZ

CR10-10 A-A-A-E-HQQE 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ

CR45-5 A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ

CR15-10 A-F-A-E-HQQE 11kW 3x400D 50Hz

TP /2-A-F-A-BAQE 400D 50HZ

CR120-2 A-F-A-E-HQQE 3x400/ HZ

CR5-26 A-FGJ-A-E-HQQE 3x400D 50HZ

CR1-6 A-A-A-E-HQQE 3x230/400 50HZ

CR1-3 A-A-A-E-HQQE 3x230/400 50HZ

CRN45-10 A-F-G-V-HQQV 3x400/ HZ

CRN A-F-G-V-HQQV 3x400/ HZ

CR10-02 A-A-A-E-HQQE 3x230/ HZ

Hydro MPC-E 2CRIE L GNL

CR3-10 A-A-A-E-HQQE 3x230/400 50HZ

CRI1-6 A-P-I-E-HQQE 3x230/400 50HZ

CR10-04 A-A-A-E-HQQE 15kW 3x400Y 50Hz

CR A-F-A-V-HQQV 3x400/ HZ

CR5-16 A-A-A-E-HQQE 3x400D 50HZ

CRN45-5 A-F-G-V-HQQV 3x400/ HZ

CRN5-7 A-P-G-E-HQQE 3x230/400 50HZ

CRI3-6 A-FGJ-I-E-HQQE 3x230/400 50HZ

CRN A-F-G-V-HQQV 30kW 3x400D 50Hz

CR10-01 A-A-A-E-HQQE 1x220/ HZ

CRN3-25 A-P-G-E-HQQE 3x400D 50HZ

CR1S-6 A-A-A-E-HQQE 1x220/240 50HZ

CR3-13 A-A-A-E-HQQE 1x220/240 50HZ

TP /4-A-F-A-BQQE 400Y 50HZ

CR1-9 A-A-A-E-HQQE 1x220/240 50HZ

CR15-02 A-F-A-E-HQQE 3x400D 50 HZ

CRN15-17 A-FGJ-G-V-HQQV 3x400/ HZ

NK /310A2F1AE-SBAQE

CRN15-03 A-P-G-V-HQQV 3x400D 50 HZ

CR3-2 A-FGJ-A-E-HQQE 3x230/400 50HZ

CRN20-02 A-FGJ-G-E-HQQE 3x400D 50 HZ

TP 40-30/4-A-F-A-BUBE 400Y 50HZ

CRN A-F-G-V-HQQV 3x400/ HZ

MTB /183 A-F-A-BQQV 400D-2 11kW

CR5-6 A-FGJ-A-E-HQQE 3x230/400 50HZ

CR3-19 A-FGJ-A-E-HQQE 3x230/400 50HZ

CRN120-7 A-F-G-V-HBQV 75kW 3x400D 50Hz

CRI10-14 A-FGJ-I-E-HQQE 3x400D 50 HZ

CRN15-09 A-P-G-V-HQQV 3x400/ HZ

CR A-F-A-V-HBQV 3x400/ HZ

TP /4-A-F-A-BUBE 400Y 50HZ

CR10-07 A-FJ-A-E-HQQE 3x400D 50 HZ

CRN15-12 A-P-G-E-HQQE 3x400/ HZ

CR3-6 A-FGJ-A-E-HQQE 1x220/240 50HZ

CR1-3 A-FGJ-A-E-HQQE 1x220/240 50HZ

TP /2-A-F-A-BQQE 400D 50HZ

CR45-3 A-F-A-E-HQQE 3x400/ HZ

CR10-08 A-A-A-E-HQQE 3x400D 50 HZ

CRN3-6 A-P-G-V-HQQV 3x230/400 50HZ

CR A-F-A-E-HQQE 3x400D 50 HZ

CRN15-01 A-P-G-V-HQQV 3x230/ HZ

CRT 16-4 A-P-A-E-AUUE 4kW 3x400D 50Hz

CRN3-3 A-FGJ-G-V-HQQV 3x230/400 50HZ

CRN1-27 A-P-G-V-HQQV 3x230/400 50HZ

NB /193 A-F2-A-BAQE

CRN3-11 A-P-G-V-HQQV 11kW 3x400Y 50Hz

CR15-14 A-F-A-E-HQQE 3x400/ HZ

CRI15-04 A-FGJ-I-E-HQQE 3x400D 50 HZ

CRE20-03 A-A-A-E-HQQE 3x HZ

CRT 8-20 A-P-A-E-AUUE 11kW 3x400D 50Hz

CR5-18 A-FGJ-A-E-HQQE 3x400D 50HZ

CRE10-02 A-A-A-E-HQQE 1x HZ

Grundfos pump

CRE15-01 A-F-A-E-HQQE 1x HZ

CRE45-1 A-F-A-E-HQQE 3x HZ

CRE5-16 A-A-A-E-HQQE 3x400 50HZ

CRN A-F-G-V-HQQV 3x400/ HZ

NB /438 A-F1-A-GQQE

CRE32-3 AN-F-A-E-HQQE 3x HZ

Transcription:

GRUNDFOS DATA BOOKLET CM5-11 A-R-G-E-AQQE F-A-A-N Grundfos Pump 96935476 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/cmbasis/96935476/cm5-11-a-r-g-e-aqqe.html info@lenntech.com tel. +31-15-261.9. fax. +31-15-261.62.89 BE > THINK > INNOVATE

Position Qty. Description 1 CM5-11 A-R-G-E-AQQE Product No.: 96935476 Compact, reliable, horizontal, multistage, end-suction centrifugal pump with axial suction port and radial discharge port. Pump materials in contact with the liquid are in high-grade stainless steel. The mechanical shaft seal is a special designed, unbalanced O-ring seal. Pipework connection is via internal Whitworth pipe threads, Rp (ISO 7/1). The pump is fitted with a 3-phase, foot-mounted, fan-cooled asynchronous motor. Further product details Pump and motor are integrated in a compact and user-friendly design. The pump is fitted to a low base plate, making it ideal for installation in systems where compactness is important. The state-of-the-art design and materials of the shaft seal ensure high wear resistance, improved sticking and dry-running capabilities and long operating life. Servicing the pump requires no special service tools. Service parts are in stock for quick delivery and are available as kits, single parts or bulk. Service videos are available on www.youtube.com. Pump A combination of a stop ring and a Nord-lock washer secures a tight and reliable fixation of the impeller spacing pipes to the splined pump shaft. It is possible to remove and fit the hydraulic parts from the pump side. The inlet and outlet port are integrated in the pump sleeve. The inlet part, chambers and discharge part are hold together by four staybolts and a retaining flange. The pump is fitted with an unbalanced O-ring seal with a rigid torque transmission system. It has a fixed seal driver ensuring a reliable rotation of all parts. The dynamic secondary seal is an O-ring. Primary seal: - Rotating seal ring material: Silicon carbide (SiC) - Stationary seat material: Silicon carbide (SiC) This material pairing is used where higher corrosion resistance is required. The high hardness of this material pairing offers good resistance against abrasive particles. Secondary seal material: EPDM (ethylene-propylene rubber) EPDM has excellent resistance to hot water. EPDM is not suitable for mineral oils. The pump shaft is connected to the motor shaft through a left thread and tight fit. The shaft cannot be dismantled. Motor The motor is a totally enclosed, fan-cooled motor with principal dimensions to EN 5347. Electrical tolerances comply with EN 634. The motor efficiency is classified as IE2 in accordance with IEC 634-3. The motor does not incorporate motor protection and must be connected to a motor-protective circuit breaker which can be manually reset. The motor-protective circuit breaker must be set according to the rated current of the motor (I1/1). An installation indicator is fitted to the motor fan cover. Based on the motor cooling air, it indicates the direction of rotation of the motor. The motor is fitted with a directional sticker.

The motor can be connected to a variable speed drive for adjustment of pump performance to any duty point. Grundfos CUE offers a range of variable speed drives. Please find more information in Grundfos Product Center. Technical data Liquid: Pumped liquid: Water Liquid temperature range: -2.. C Liquid temperature during operation: 2 C Density: 998.2 kg/m³ Technical: Speed for pump data: Rated flow: Rated head: Primary shaft seal: Approvals on nameplate: Curve tolerance: Materials: Pump housing: Impeller: Rubber: 2 rpm 4.7 m³/h 86.2 m AQQE CE,WRAS,ACS,TR,EAC ISO96:212 3B Stainless steel DIN W.-Nr. 1.441 AISI 316 Stainless steel DIN W.-Nr. 1.441 AISI 316 EPDM Installation: Maximum ambient temperature: 55 C Maximum operating pressure: 16 bar Max pressure at stated temp: 16 bar / C Flange standard: WHITWORTH THREAD RP Pump inlet: Rp 1 1/4 Pump outlet: Rp 1 Electrical data: Motor type: SC IE Efficiency class: IE2 Rated power - P2: 2.2 kw Mains frequency: 5 Hz Rated voltage: 3 x 22-24D/38-415Y V Service factor: 1 Rated current: 8,15-7,85/4,7-4,5 A Starting current: 8-2 % Rated speed: 288-29 rpm Motor efficiency at full load: 83.2 % Enclosure class (IEC 34-5): IP55 Insulation class (IEC 85): F Others: Minimum efficiency index, MEI :,7 Net weight: 29 kg Gross weight: 31.5 kg

96935476 CM5-11 5 Hz H [m] CM5-11, 3*4 V, 5Hz eta [%] 1 8 8 7 7 6 6 5 5 4 4 3 3 2 2.5 1. 1.5 2. 2.5 3. 3.5 4. 4.5 5. 5.5 6. P [kw] Q [m³/h] NPSH [m] 3. 12 2.5 P1 2. P2 8 1.5 6 1. 4.5 2.

Rp 1 1/4 Rp 1 178 155 31.6 58.8 14 125 316.6 18.3 199.5 178 215.6 264.2 365.2 Description Value General information: Product name: CM5-11 A-R-G-E-AQQE Product No: 96935476 EAN number: 573145384 Technical: Speed for pump data: 2 rpm Rated flow: 4.7 m³/h Rated head: 86.2 m Impellers: 11 Primary shaft seal: AQQE Approvals on nameplate: CE,WRAS,ACS,TR,EAC Curve tolerance: ISO96:212 3B Pump version: A Model: A Materials: Pump housing: Stainless steel DIN W.-Nr. 1.441 AISI 316 Impeller: Stainless steel DIN W.-Nr. 1.441 AISI 316 Material code: G Rubber: EPDM Code for rubber: E Installation: Maximum ambient temperature: 55 C Maximum operating pressure: 16 bar Max pressure at stated temp: 16 bar / C Flange standard: WHITWORTH THREAD RP Connect code: R Pump inlet: Rp 1 1/4 Pump outlet: Rp 1 Liquid: Pumped liquid: Water Liquid temperature range: -2.. C Liquid temperature during operation: 2 C Density: 998.2 kg/m³ Electrical data: Motor type: SC IE Efficiency class: IE2 Rated power - P2: 2.2 kw Mains frequency: 5 Hz Rated voltage: 3 x 22-24D/38-415Y V Service factor: 1 Rated current: 8,15-7,85/4,7-4,5 A Starting current: 8-2 % Rated speed: 288-29 rpm Motor efficiency at full load: 83.2 % Enclosure class (IEC 34-5): IP55 Insulation class (IEC 85): F Motor protec: NO Others: Minimum efficiency index, MEI :,7 Net weight: 29 kg Gross weight: 31.5 kg H [m] 1 8 7 6 5 4 3 2 CM5-11, 3*4 V, 5Hz.5 1.5 2.5 3.5 4.5 5.5 P [kw] 2.5 2. 1.5 1..5. TO AMPLIFIER RELAY TO AMPLIFIER +T 178 14 178 +T +T +T L1 L2 L3 +T +T 199.5 18.3 264.2 IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE 365.2 CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY 125 155 THERMISTORS PTC ACCORDING TO DIN 4482 58.8 316.6 215.6 31.6 Q [m³/h] P1 P2 Rp 1 8 7 6 5 4 3 2 eta [%] 8 6 4 2 Rp 1 1/4 NPSH [m] RELAY L1 L2 L3

96935476 CM5-11 5 Hz cos phi eta CM5-11 + SC 2.2 kw 3*4 V, 5 Hz, SF = 1 I [A] I eta.8 cos phi 4..6 3..4 2..2 1...1.2.3.4.5.6.7.8.9 1. 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2. 2.1 n [rpm] P2 [kw]. P1 [kw] 3 P1 n 28 2. 26 1. 24.

96935476 CM5-11 5 Hz 178 14 178 18.3 199.5 264.2 365.2 125 155 58.8 215.6 316.6 31.6 Rp 1 Rp 1 1/4 Note! All units are in [mm] unless others are stated. Disclaimer: This simplified dimensional drawing does not show all details.

96935476 CM5-11 5 Hz +T +T +T TO AMPLIFIER RELAY +T TO AMPLIFIER RELAY L1 L2 L3 +T +T L1 L2 L3 IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY THERMISTORS PTC ACCORDING TO DIN 4482 Note! All units are in [mm] unless others are stated.

Disclaimer: The information about the Grundfos pump in this document may be outdated. Data may be subject to alterations without further notice. Please contact us to verify the data above is still accurate/up-to-date. All information is copyright Grundfos. info@lenntech.com www.lenntech.com tel. +31-15-261.9. fax. +31-15-261.62.89