CYCLON SELECTION GUIDE

Similar documents
SELECTION GUIDE 1973 TO 2008

AINO MICRO RANGE VRLA. Compact energy for increased security BATTERY SOLUTIONS. EverExceed power your applications

Battery Selection Guide

Battery Range Summary

6 & 12 Volt Monobloc. Haze Battery Company Ltd

SECTION A Division of Exide Technologies

Modular Max Range BATTERY SOLUTIONS. NEBS qualified. Reliable capacities. EverExceed power your applications

Pure Lead-Tin Technology

Features and Benefits

LIBERTY SERIES 1000 VALVE REGULATED LEAD-CALCIUM BATTERY For standby applications Capacities from 25 to 600 Ampere-hours

MHR VRLA batteries are manufactured in compliance with TL, NEBS, GR, SR, IEC, BS, UL, ISO, OSHAS and CE quality and performance standards.

SECTION TECHNOLOGIES I NDUSTRIAL E NERGY

SECTION

SPA AGM VRLA batteries

FAT. FAT Battery Range FIAMM.COM

Switchgear Utility specific gravity nominal sulfuric acid. 10 years, full float service at 77 F (25 C)

Tubular Gel Technology For Solar Applications

SECTION A Division of Exide Technologies

Standby Products SD-SDH. series. Technical Features. Applications. Product Features

Applications. EMC tested

2 Volt AGM Range. Haze Battery Company Ltd

Modular Max AGM Range VRLA

Deep Cycle AGM Range VRLA

SECTION 26.10C

Power to keep you on the move

SECTION

Single Cell Range including LCE P LBE P

PURE LEAD PLUS UPS APPLICATIONS. Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell

Battery Performance Specifications

Haze Battery Company Ltd. Sealed Lead Acid 6 & 12 Volt. AGM Range. Monobloc

6 & 12 Volt Monobloc GEL Range

Haze Battery Company Ltd

OPzV Batteries. Technical Data

SECTION 26.10C A Division of Exide Technologies

SECTION

RES OPzV Premium Quality Batteries. for Renewable Energy Storage

RES OPzV Premium Quality Batteries. for Renewable Energy Storage

SECTION

NorthStar Battery Company DOC Code: SES DCR-721-S05 Date:

Long Duration MCT LEAD CALCIUM H1T LEAD CALCIUM SECTION

PURE LEAD PLUS UPS APPLICATIONS Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell

NorthStar Battery Company DCN: SES DCR: 1413-S08 Date:

NorthStar Battery Company DCN: SES DCR: 1548-S09 Date:

DataSafe HX Top Terminated Batteries 6 and 12 Volt HX

Sealed Lead-Acid Batteries

Haze Battery Company Ltd

FEATURES & benefits. Constant Power Discharge Ratings - Watts per 77 F (25 F) Operating Time (in minutes) to 1.

Haze Battery Company Ltd. Sealed Lead Acid 6 & 12 Volt. Gelled Electrolyte Range. Monobloc

SECTION A Division of Exide Technologies

Haze Battery Company Ltd. Sealed Lead Acid 6 & 12 Volt. AGM Range. Monobloc

SD / SDH. Applicable Standards. Applications and Key Benefits. FIAMM Manufacturing. - Technical Features

Haze Battery Company Ltd. Sealed Lead Acid 2 Volt Bloc. Gelled Electrolyte Range

INTRODUCING THE LEAD CRYSTAL BATTERY

Tubular Flooded (OPzS) Batteries

Stationary batteries with modified tubular electrodes

Haze Battery Company Ltd

Product Guide. An Invensys company

Valve Regulated Lead Acid (VRLA) Battery Series Designed for UPS Standby Power Applications FEATURES & BENEFITS

Sealed Lead-Acid Batteries

OPzV Batteries for Stationary Applications

Tubular Gel (OPzV) Batteries. Stationary & Renewable Energy Applications

Tubular Flooded (OPzS) Batteries

LIBERTY 2000 SuperMAX For standby applications Capacities from 295 to 2000 Ampere-hours

EcoSafe EOPzV. Operation Guide for Solar Applications

Nominal Voltage. Capacity (C20)

Prepared for 7 x 24 Exchange

SSLA. SSLA Battery Range FIAMM.COM

SSLA. SSLA Battery Range FIAMM.COM

Wide operating temperature range: Our battery will operate from -30C to (-22F) to 60C when it is fully charged.

UPS FEATURES & BENEFITS TECHNICAL DATA Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications.

OPzV Batteries. for Stationary Applications

OPzV Batteries. for Stationary Applications

ANNEXURE XI. (Ni Cd Battery Bank) TECHNICAL SPECIFICATIONS OF 125V STATION BATTERY BANK OF GTG I.

SPECIFICATIONS. Top Terminal Batteries. SECTION A Division of Exide Technologies

PERFORMANCE SPECIFICATIONS

FEATURES & BENEFITS. 10 year design 25 C

Vented fibre structure Nickel Cadmium batteries for stationary systems

PRODUCT GUIDE Publication No: EN-SBS-PG-001 February 2003

Batteries for Renewable Energy Applications

attery Application Handbook

PowerSafe OPzV Operation Guide for Solar Applications

Operation Manual. For GTS-L Range Stationary VRLA Batteries

Fuse & Switch. BUCHANAN Terminal Blocks. Product Facts High Density Blocks. Fuse Blocks. Switch Blocks. Common Features of 300 & 0300 Series

1 2 V F T A S E R I E S

IEC APPROVAL TESTS

XHP. Low maintenance high performance batteries

VGS. series (OPzV) GLOBAL OPzV Valve Regulated Sealed Industrial Battery

LITHIUM-ION POLYMER RECHARGEABLE BATTERY

Batteries for HTM. Basic Battery Parameters:

EV Traction Dry Cell Battery Technology

EV Traction Dry Cell Battery Technology

Ampere Hour 77 F (25 C) Weight Weight Model #Cells/Voltage

PS-Series General Purpose Batteries

Low maintenance TAB OPzS vented stationary batteries

SEC. MICROLYTE +Plus. Industrial Battery Co. Supplied Worldwide by: Visit our website on Features. Application

Batteries for HTM. D. J. McMahon rev cewood

V R L A HI-PERFORMANCE BATTERIES

[Charge] [Lead dioxide] [Lead] [Sulfuric acid] [Lead sulfate] [Lead sulfate] [Water]

CALL FOR A QUOTE (877)

Reserve Power OPzV Batteries

Transcription:

CYCLON PRODUCT AILY (All capacities at 0 hr. rate 25 C to.67 vpc) CYCLON 2V single cell: DIENSIONS Internal res. Nominal short eight with Products Part of fully charged circuit current for Diameter eight terminals Weight Tabs (capacity) Number cell mω @ 25 C charged cell in. (mm) in. (mm) in. (mm) oz. (gm) in. (mm) D cell 080-0004 5.0 400A.35 2.4 2.68 6.28.87 x.025 (2.5Ah) (34.3) (6.2) (68.) (78.0) (4.75 x 0.64) DT cell 0860-0004 5.0 400A.35 3.78 4.05 9.68.87x.025 (4.5Ah) (34.3) (96.0) (02.9) (274.4) (4.75 x 0.64) X cell 0800-0004 3.5 570A.75 2.87 3.2 2.77.250 x.025 (5.0Ah) (44.5) (72.9) (8.5) (362.0) (6.35 x 0.64) E cell 0850-0004 3.0 665A.75 3.94 4.28 7.28.250 x.025 (8.0Ah) (44.5) (00.) (08.7) (489.9) (6.35 x 0.64) cell 0840-0004 2.5 800A 2.04 4.85 5.34 29.60 0.32 x 0.032 (2.0Ah) (5.8) (23.2) (35.6) (839.2) (7.92 x 0.8) C cell 0820-0004.5 335A 2.57 6.25 6.82 58.88 6 (-) and (25Ah) (65.3) (58.8) (73.2) (669.2) 8 (+) terminals CYCLON 4V monobloc: Internal res. of fully charged Nominal short DIENSIONS Products Part onobloc mω circuit current for Length Width eight Weight Tabs (capacity) Number @ 25 C charged onobloc in. (mm) in. (mm) in. (mm) lb. (kg) in. (mm) D 089-000 0.0 400A 3.3.8 2.75.80 0.87 x.025 (2.5Ah) (79.5) (46.0) (69.9) (.36) (4.75 x 0.64) X 0809-000 7.0 570A 3.80 2.2 3.02.62.250 x.025 (5.0Ah) (96.5) (53.8) (76.7) (.74) (6.35 x 0.64) E 0859-000 6.0 665A 3.8 2.3 4.00 2. 0.250 x.025 (8.0Ah) (96.8) (54.) (0.6) (.96) (6.35 x 0.64) CYCLON 6V monobloc: Internal res. of fully charged Nominal short DIENSIONS Products Part onobloc mω circuit current for Length Width eight Weight Tabs (capacity) Number @ 25 C charged onobloc in. (mm) in. (mm) in. (mm) lb. (kg) in. (mm) D 089-002 5.0 400A 4.48.8 2.75.5 0.87 x.025 (2.5Ah) (3.8) (46.0) (69.9) (.52) (4.75 x 0.64) X 0809-002 0.0 570A 5.48 2.2 3.02 2.6 0.250 x.025 (5.0Ah) (39.2) (53.8) (76.7) (.98) (6.35 x 0.64) E 0859-002 8.0 665A 5.48 2.3 4.00 3.5 0.250 x.025 (8.0Ah) (39.2) (54.) (0.6) (.43) (6.35 x 0.64) All dimensions, excluding weight and tabs, are maximum 9 Certificate Number ES 39520, ISO 400 Certified Certificate Number 32099, ISO 900 Certified

CYCLON SINGLE CELL igh integrity terminal seal Resealable Safety vent Plastic internal container Positive and negative plates Lead grids ighly retentive separator etal can enclosure ALTERNATIVE ATTERY CONIGURATIONS Standard battery configurations are rectangular in overall shape. A sample of other possible configurations are illustrated below. These can be held together with tape (offering the lowest cost and minimum electrical and mechanical protection) or by shrink wrapping. The CYCLON Single Cell can be custom configured in virtually an infinite number of designs. Rectangular Rhomboid Trapezoid Nested Tubular lat Pack Certificate Number ES 39520, ISO 400 Certified Certificate Number 32099, ISO 900 Certified 0

CYCLON STANDARD ATTERY DESCRIPTIONS CYCLON cells are ideal for small ampere-hour applications up to 25Ah. The sealed-lead construction uses a starved-electrolyte system and a patented grid-alloy providing numerous advantages. Standard batteries are offered based on combinations of the previously described CYCLON cells and are available in 6 and 2 volt configurations with capacities ranging from 2.5Ah to 25Ah. attery Packages Rigid plastic cases or shrink wrap packaging are available. Rigid Plastic Cases are available for most designs in either flame-retardant AS Cycolac (General Electric) material, meeting UL 94V-0 flammability rating, or Styrene (available only in 2X3 D and X battery configurations). Some cases have mounting holes. Rigid plastic cases are recommended for applications in which the battery must withstand vibration, movement or extreme weather conditions. Shrink Wrap Shrink wrap packaging is less expensive and smaller in size and weight. A plastic extrusion insulates the battery top and keeps the cells in line. A heavy duty shrink sleeve holds the cells firmly in place. Shrink wrap packaging is recommended for applications in which the battery remains stationary. attery Terminations for Single Cell and onoblocs Tab/Stud Cell size Dimensions D.87" X.025" DT.87" X.025" X.250" X.025" E.250" X.025".32" X.032" C 6mm post (negative) 8mm post (positive) C Quick Disconnect Terminals AP series 250 aston terminals are available for C batteries. Connection Terminations A wide variety of terminations are offered. or recommendations or to specify; contact your awker Territory anager or battery assembler. usible Links Specify your requirement. Lead Wires Stranded copper wire with insulation meeting UL05 specifications (Red +, lack -). Standard leads extend 9 inches outside the battery pack. Ends are stripped and dipped in wax, which must be removed before use. Standard wire gauges are: D batteries DT batteries X batteries E batteries batteries C batteries 8AWG, UL05 6AWG, UL05 6AWG, UL05 4AWG, UL05 4AWG, UL05 2AWG, UL05 Varying lead lengths and gauges are also available; please specify to your awker Territory anager or battery assembler. Intercell Connections Standard D, DT, X and E batteries welded tin-plated steel connector batteries soldered, stranded wire C batteries solid copper or vibration-prone applications D, DT, X, E and batteries soldered, stranded wire C batteries braided copper straps Tab Adapters (D, DT, X, and E) Available to convert.87" tabs to.250" tabs, 0.032" thick, and vice versa. Certificate Number ES 39520, ISO 400 Certified Certificate Number 32099, ISO 900 Certified

CYCLON SINGLE CELL PERORANCE SPECIICATIONS Constant current discharge/amps to.67 vpc @ 25 C DURATION Products 5 min. 0 min. 5min. 30 min. 60 min. 90 min. 5 hr. 8 hr. 0 hr. 20 hr. D cell (2.5Ah) 4.8 8. 5.9 3.4.9.4.48.32.26.3 DT cell (4.5Ah) 25.2 5.0.2 6.6 3.7 2.6.85.55.45.24 X cell (5.0Ah) 27.3 7.8 3.2 7.0 3.9 2.8.96.6.50.26 E cell (8.0Ah) 4.7 26.4 9.0.0 6.2 4.4.6.0.8.42 cell (2.0Ah) 5.7 38. 29.4 8.0 9.2 6.5 2.3.5.20.66 Constant power discharge/watts per cell to.67 vpc @ 25 C DURATION Products 5 min. 0 min. 5min. 30 min. 60 min. 90 min. 5 hr. 8 hr. 0 hr. 20 hr. D cell (2.5Ah) 26.4 6..6 6.7 3.8 2.7.94.6.50.25 DT cell (4.5Ah) 45.0 28. 2.0 2.5 7. 5..7..90.46 X cell (5.0Ah) 45.4 3.9 23.9 3.9 7.8 5.6.9.2.0.5 E cell (8.0Ah) 77.8 5.0 35.5 2. 2.4 8.9 3. 2.0.6.85 cell (2.0Ah) 90.4 68.4 53.4 3.6 8.3 3.2 4.7 3.0 2.3.3 Charging/Temperature/Life: CARGING PER CELL TEPERATURE RANGE LIE EXPECTANCY Storage & C/5 Cycle life loat life at Products Cyclic loat discharge Charge 00% DOD 25 C (20 C) D, DT, X, E & cell CV 2.45 2.50 CV 2.27 2.35-65 C to +80 C -40 C to +80 C 300 0 years CC* CC* (5 years) aximum recommended storage time before recharge 24 months @ 25 C or 2.0vpc, whichever is earlier Atmospheric pressure range Vacuum to 8 atmospheres * Users planning to use CC should consult the awker Application Support Department UL Recognized Component. eets UL 989 Caution: atteries contain toxic materials (Pb and 2SO 4) Avoid short circuit Do not charge in gas-tight container Sealed-lead rechargeable battery must be recycled or disposed of properly. Contact awker Customer Service for details. Certificate Number ES 39520, ISO 400 Certified Certificate Number 32099, ISO 900 Certified 2

CYCLON SINGLE CELL CONSTANT CURRENT (CC) DISCARGE 000 000 Amperes per cell 00 00 0 0 0. 0. 0.0 0. 0 50 ours to.67 VPC at 25ºC Amperes per cell D (2.5Ah) X (5.0Ah) (2.0Ah) DT (4.5Ah) E (8.0Ah) C (25.0Ah) CYCLON SINGLE CELL CONSTANT POWER (CP) DISCARGE 000 000 Watts per cell 00 0 0. 00 0 0. 0.0 0. 0 50 ours to.67 VPC at 25ºC Watts per cell D (2.5Ah) X (5.0Ah) (2.0Ah) DT (4.5Ah) E (8.0Ah) C (25.0Ah) Certificate Number ES 39520, ISO 400 Certified Certificate Number 32099, ISO 900 Certified 6