KSEV97X. IT Libretto Istruzioni GB Instruction Manual. 11 FR Manuel d Instructions 20 DE Bedienungsanleitung 29 NL Gebruiksaanwijzing

Similar documents
RMHDT90SS/ - RMHDT100SS/ - RMHDT110SS/ Instructions Manual.

EFC Instructions Manual

LEIHDS110SC/ LEIHDS110BC/ Instructions Manual.

Instructions for use and installation Cooker Hood

INDEX RECOMMENDATIONS AND SUGGESTIONS... 3 CHARACTERISTICS... 6 INSTALLATION USE MAINTENANCE... 33

INSTRUCTIONS FOR MAINTENANCE AND USE KITCHEN EXTRACTOR HOOD ZRW 50/60

KH E, KH E

INSTRUCTIONS FOR INSTALLATION AND USE

BEDIENUNGSANWEISUNG KD KD KD KD KD KDEM KDEM mit Montageanweisungen

Hood. warning. warning. caution

Instructions for use L 2015

RI.15KI. L Rev. 04/03/02 MIKROCONTROLLER-STEUERUNG FÜR. Betriebsanleitung

When Time Matters! listed Fire Damper

Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon Telephone: (541) Fax: (541)

TYPE 41LA MINING LED LUMINAIRE EXPLOSION PROOF LUMINAIRE WITH FLAMEPROOF PROTECTION (TYPE d)

b3c OPERATING MANUAL (GB) 9260(A) (A) 9360 Compacts scales 9260 (A) Ver 2014 EN September BC

Mod: KLD6-12/35XLAS-N

Charcoal Filter Installation NOTE: The charcoal filters are preinstalled if you purchased the range hood with re-circulating kit from us. 1. Remove st

NUTONE RANGE HOOD NTM SERIES

220/240 AC x 25 W

HR25 Solo. Installation and User Instructions. Through the Wall Heat Recovery Ventilators

120 Ventilation. Ventilation. Removes smoke and odor. Adds exceptional style.

PETROL GENERATOR PGH2200, PGH3000, PGH6500 OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.

PETROL GENERATOR SPG2200, SPG3000, SPG6500 OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.

HOODS HOODS PLAY AN IMPORTANT ROLE IN THE KITCHEN, BOTH AESTHETIC AND FUNCTIONAL. DESIGNED. Range Versatility

READ AND SAVE THE INSTRUCTIONS

TYPE NO. AS APPROPRIATE

! FOR DOMESTIC COOKING ONLY!

rangehoods SA520TX90 90cm telescopic rangehood SA520TX60 60cm telescopic rangehood

SAUTER TVO Version /2014 GB

User manual / 230 V. Electronically controlled motor, constant torque with intermediate reverse

Operation Manual RANGE HOOD

Suction Unit SG-10 Single Workbench Suction Unit

Suction unit SG-10 USER MANUAL. SG-10 standard version (REF ) SG-10 activated carbon version (REF )

Model U102E ENGLISH...2 FRANÇAIS...15 ESPAÑOL A. BEST BY BROAN, P. O. Box 140, Hartford, WI 53027

Wall Mount Chimney Style. Island Mount Chimney Style. Wall Mount Professional Style. Insert Mount Professional Style

Q Max. (Free Outlet Delivery ) m³/h. **Lw Max. dba. **Lw Min. dba. ECO INTERIOR Motors (inside the hood)

Use, Care and Installation Guide Guide d utilisation, d entretien et d installation Guía de instalación, uso y mantenimiento.

RoboSterz. Automatic Management of Steering Without Operator ITA. Mod. V.

EXHAUST HOODS HNPD, HNPA, HPPD, HFPD, HNCD, HNCA, HPCD, HFCD, HKCD, HNPDC. Installation, Operation and Maintenance Manual

Light oil - kerosene burner

Operating manual FP-2. Index

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

Ventilation technology COMPAIR. Power. Ventilation technology

PRE-SWEEP / DUST CONTROL KIT. For Advance Hydro-Retriever 3800 / Nilfisk BR 1000 CONTENTS OF KIT

INSTRUCTIONS FOR OPERATION

Staging the fire without wasting energy

Multi place suction unit SG-20

INSTALLATION INSTRUCTIONS ISLAND LINER INSERT

SARGON S - M - L. All rights reserved INSTALLATION MANUAL

T35 W35. Thermoelectric cooler Instruction Manual 6. Thermoelektrische Kühlbox Bedienungsanleitung 16. Glacière thermoélectrique Notice d emploi 27

LDG6000SA DIESEL GENERATOR OWNERS MANUAL

Q35 Series Automatic Vent Damper System

GENERATOR MODEL NO: FG3000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0609

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

Preparation Advanced Preparations: Be familiar with the controls of the range hood by reading through Range Hood Operations, Page 12. Place the range

WhispAire Range Hood Quiet Hood

General Description. Product Specification. Document Digital Temperature Interlock

Vario-Jet automatic No Bedienungsanleitung Instruction Manual Mode d emploi Modo d impiego Instrucciones para el servicio Handleiding

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

! FOR DOMESTIC COOKING ONLY!!

VICTRIX PRO Wall-hung modular condensing boiler for heating only

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

AQUATEC R / AQUATEC F / AQUATEC XL. Bathlift Operating instructions

INVERTER GENERATOR OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.

Operating Instruction Manual of Energy Management System EBL 208, Art.-No Seite 1 / 7

Viking Installation Guide

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

FITTING AND CONNECTION INSTRUCTIONS

1200W INVERTER GENERATOR

ECD 16,8. Art.-No.: Operating Instructions Battery-powered Drill/Screwdriver with Adjustable Torque

Pro and Designer Series Ventilation

INSTALLATION MANUAL TDR - ROTISSERIE OVEN MODELS

Ohaus ES Series Bench Scale

Flue installation instructions. Air flue duct for use with ecomax and ecotec boilers. For the installer

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

RA-7730SS RA-7736SS RA-7742SS RA-7748SS. For residential and indoor use only.

GEIGER-SoftPerfection (GR45..E03) for rolling shutters with stoppers and anti-lift device

Industrial flue gas probes. Instruction manual

KENSUN HID AUTOMOTIVE HEAD LAMP CONVERSION KIT INSTALLATION MANUAL

GE Monogram. Installation. Instructions. Professional Vent Hoods. 48" Models ZV881WSS, ZV891YSS ZV880WSS, ZV890YSS. 36" Models ZV671WSS, ZV681YSS

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

Instruction Manual for Ceramics up to 1320 C

User Guide for Logo Projector

DC TO AC POWER INVERTER

Diesel Cooker X 100. Installation Instructions

Safety Precaution. Notation. Meaning of symbols WARNING CAUTION

Designer Wall Range Hood Installation. Installation Tutorial Video

ROBERT H. PETERSON CO. AUTOMATIC REMOTE LIGHTING SAFETY PILOT SYSTEM WITH VARIABLE FLAME-HEIGHT REMOTE FOR NATURAL OR PROPANE GAS. Model APK-17(M)(P)

Astor 20 Colony Counter User s Manual

INSTALLATION MANUAL STG - ROTISSERIE OVEN MODELS STW - WARMER MODELS

Typical Installation Schematic

! FOR DOMESTIC COOKING ONLY!

ETHANOL 1100 FIREPLACE OWNER S MANUAL

AXIAL FANS Axis / Tubo OPERATION MANUAL

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

Transcription:

IT Libretto Istruzioni 2 Instruction Manual 11 FR Manuel d Instructions 20 DE Bedienungsanleitung 29 NL Gebruiksaanwijzing 38 ES Manual de Instrucciones 47 KSEV97X

Dear Customer, If you follow the recommendations contained in this Instruction Manual, your appliance will give you constant high performance and will remain efficient for many years to come. CONTENTS RECOMMENDATIONS AND SUGGESTIONS 12 CHARACTERISTICS 13 INSTALLATION 14 USE 17 MAINTENANCE 18 11

RECOMMENDATIONS AND SUGGESTIONS INSTALLATION The manufacturer will not be held liable for any damages resulting from incorrect or improper installation. The minimum safety distance between the cooker top and the extractor hood is 650 mm. Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood. For Class 1 a appliances, check that the domestic power supply guarantees adequate earthing. Connect the extractor to the exhaust flue through a pipe of minimum diameter 120 mm. The route of the flue must be as short as possible. Do not connect the extractor hood to exhaust ducts carrying combustion fumes (boilers, fireplaces, etc.). If the extractor is used in conjunction with non-electrical appliances (e.g. gas burning appliances), a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas. The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air. 650 mm min. USE The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells. Never use the hood for purposes other than for which it has ben designed. Never leave high naked flames under the hood when it is in operation. Adjust the flame intensity to direct it onto the bottom of the pan only, making sure that it does not engulf the sides. Deep fat fryers must be continuously monitored during use: overheated oil can burst into flames. The hood should not be used by children or persons not instructed in its correct use. MAINTENANCE Switch off or unplug the appliance from the mains supply before carrying out any maintenance work. Clean and/or replace the Filters after the specified time period. Clean the hood using a damp cloth and a neutral liquid detergent. 12

CHARACTERISTICS Dimensions 260 300 68 310 740 80 740 min 950 max 898 500 Components 10 15 14.1 12a 7.2.1 11 Ref. Q.ty Product Components 1 1 Hood Body, complete with: Controls, Light, Blower, Filters 2 1 Telescopic Chimney comprising: 2.1 1 Upper Section 2.2 1 Lower Section 10 1 Damper 14.1 1 Air Outlet Connection Extension 15 1 Air Outlet Connection 2 2.1 2.2 12c Ref. Q.ty Installation Components 7.2.1 2 Upper Chimney Section Fixing Brackets 11 6 Wall Plugs 12a 6 Screws 4,2 x 44,4 12c 6 Screws 2,9 x 9,5 Q.ty Documentation 1 Instruction Manual 11 12a 1 13

INSTALLATION Wall drilling and bracket fixing 1 2 7.2.1 11 12a 116 116 650 min. 328 X Wall marking: Draw a vertical line on the supporting wall up to the ceiling, or as high as practical, at the centre of the area in which the hood will be installed. Draw a horizontal line at 650 mm above the hob. Place bracket 7.2.1 on the wall as shown about 1-2 mm from the ceiling or upper limit aligning the centre (notch) with the vertical reference line. Mark the wall at the centres of the holes in the bracket. Place bracket 7.2.1 on the wall as shown at X mm below the first bracket (X = height of the upper chimney section supplied), aligning the centre (notch) with the vertical line. Mark the wall at the centres of the holes in the bracket. Mark a reference point as indicated at 116 mm from the vertical reference line and 328 mm above the horizontal reference line. Repeat this operation on the other side. Drill ø 8 mm holes at all the centre points marked. Insert the wall plugs 11 in the holes. Fix the brackets using the 12a (4,2 x 44,4) screws supplied. Insert the two screws 12a (4,2 x 44,4) supplied in the hood body fixing holes, leaving a gap of 5-6 mm between the wall and the head of the screw. 14

Mounting the hood body Before attaching the hood body, tighten the two screws Vr located on the hood body mounting points. Hook the hood body onto the screws 12a Fully tighten support screws 12a Adjust screws Vr to level the hood body Vr 12a Connections DUCTED VERSION AIR EXHAUST SYSTEM In order to install the ducted version, connect the hood to the chimney using either a flexible or rigid pipe ø 150 mm, the choice of which is left to the installer. Push fit Damper 10 onto the air outlet. Fix the pipe in position using sufficient pipe clamps (not supplied). Remove any activated charcoal filters. ø 150 10 RECIRCULATION VERSION AIR OUTLET Push fit connection 15 onto the air outlet. Insert the connection extension pieces laterally 14.1 in connection 15. Make sure that the outlet of the extension pieces 14.1 is horizontally and vertically aligned with the chimney outlets. If this is not the case, adjust the position by either reversing the connection extension pieces 14.1 or by pushing connector 15 all the way in. Ensure that the activated charcoal filters have been inserted. 15 14.1 15

ELECTRICAL CONNECTION Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm. Flue assembly Upper exhaust flue Slightly widen the two sides of the upper flue and hook them behind the brackets 7.2.1, making sure that they are well seated. Secure the sides to the brackets using the 4 screws 12c (2,9 x 9,5) supplied. Lower exhaust flue Slightly widen the two sides of the flue and hook them between the upper flue and the wall, making sure that they are well seated. Fix the lower part laterally to the hood body using the 2 screws 12c (2,9 x 9,5) supplied. 2 2.1 2.2 7.2.1 12c 8a 2.1 2.2 2 8b 7.2.1 12c. 12c 16

USE Control panel S1 S2 R L M V1 V2 V3 L Light Switches the lighting system on and off. S1 Led Motor running led. It flashes once after 100 working hours of the hood to indicate that the grease filters need washing. It flashes twice after 200 working hours to indicate that the grease filters need washing and that the anti-odour charcoal filters, if any, need changing. S2 Led Intensive speed led. M Motor Switches the extractor motor on and off at low speed. Used to provide a continuos and silent air change in the presence of light cooking vapours. When the Hood is in ELC (Electronic Comfort) mode, the button will not only turn the Ducting motor on, but will also disable this function. V1 Speed Reduces the operating speed. When the button is pressed with the Motor off, ELC (Electronic Comfort) mode will be enabled again, giving a continuous, low noise flow of air. Press the button and hold it until Led S1 flashes slowly. V2 Speed V3 Intensive Speed Increases the operating speed. Maximum speed, used for eliminating the highest cooking vapour emission. Switches off automatically after 10 minutes operation. Can also be switched off manually by pressing the button. R Receiver for Optional Remote Control. Remote Control 17

MAINTENANCE Grease filters CLEANING METAL SELF- SUPPORTING GREASE FILTERS Alarm signal reset Switch off the lights and extractor motor. Press button V2 for at least 3 seconds, until the leds start to flash. Cleaning the filters The filters must be cleaned when led S1 flashes or at least every 2 months of operation, or more frequently for particularly heavy usage. Remove the filters one at a time by pushing them towards the back of the group and pulling down at the same time. Wash the filters, taking care not to bend them. Allow them to dry before refitting. When refitting the filters, make sure that the handle is visible on the outside. 18

Activated charcoal filter (Recirculation version) REPLACING THE ACTIVATED CHARCOAL FILTER The filter is not washable and cannot be regenerated. It must be replaced when led S1 flashes twice or at least every 4 months. The alarm signal will only light up when the extractor motor is switched on. Alarm signal reset Switch off the lights and extractor motor. Press button V2 for at least 3 seconds, until the leds start to flash. Replacing the Filter Remove the metal grease filters. Remove the saturated activated carbon filter by releasing the fixing hooks. Fit the new filter by hooking it into its seating Replace the metal grease filters. Alarm signal activation On the recirulcation version extractor hood, the filter saturation alarm is activated during installation or at a later date. Switch off the lights and extractor motor. Press button V2 for at least 10 seconds, until the leds start to flash: 2 flashes of the activated carbon odour filter saturation alarm led = filter ACTIVATED 1 flash of the activated carbon odour filter saturation alarm led = filter DEACTIVATED Lighting LIGHT REPLACEMENT 20 W halogen light. Remove the 2 Screws fixing the Lighting support, and pull it out of from the Hood. Extract the Lamp from the Support. Replace with another of the same type, making sure that the two pins are properly inserted in the lamp holder socket holes. Replace the Support, fixing it in place with the two Screws removed as above. 19

Quest apparecchio è conforme alla norma europea sulla bassa tensione C.E.E. 73/23 relativa alla sicurezza elettrica e alle norme europee: C.E.E. 89/336 relativa alla compatibilità elettromagnetica e C.E.E. 93/68 relativa alla marcatura CE. This appliance conforms to European Low Voltage Directive 73/23/CEE governing electrical safety, European Directive 89/336/CEE on Electromagnetic Compatibility and Directive 93/68/CEE regarding CE Marking. Cet appareil est conforme à la norme européenne en matière de basse tension C.E.E. 73/23 de sécurité électrique ainsi qu aux normes européennes : C.E.E. 89/336 en matière de compatibilité électromagnétique et C.E.E. 93/68 en matière de label CE. Dieses Gerät entspricht folgenden EG-Richtlinien: Niederspannungsrichtlinie EWG 73/23 hinsichtlich elektrischer Sicherheit, Richtlinie Elektromagnetische Verträglichkeit EWG 89/336 und Richtlinie EWG 93/68 hinsichtlich der CE-Kennzeichnung. Dit apparaat voldoet aan de Europese laagspanningsnorm 73/23/EEG inzake de elektrische veiligheid en de Europese normen: 89/336/ EEG inzake de elektromagnetische compatibiliteit en 93/68/EEG inzake de CE-markering. Este aparato es conforme con la normativa europea sobre baja tensión C.E.E. 73/23 correspondiente a la seguridad eléctrica y a las normativas europeas: C.E.E. 89/336 sobre la compatibilidad electromagnética e C.E.E. 93/68 respeitante à marcação CE. 436001636 03-021219