M2S. Indicator Series with Square 40-mm Body. Indicator (Square) List of Models

Similar documents
A3S. Pushbutton Switch Series with Square 40-mm Body. Lighted Pushbutton Switch (Square) List of Models

A165S/W. Separate Construction with Cylindrical 16-dia. Body. Knob-type Selector Switch (Detachable) (Cylindrical 16-dia.

2NC (slow-action) Direct. Model. opening

A165E CSM_A165E_DS_E_11_2

Digital display Pressure range ON/OFF output Linear output Model

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

G3PE-Single-phase. Solid State Relays for Heaters

Multiple Limit Switch

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

D4BS CSM_D4BS_DS_E_8_4

S8JX-N/S8JX-G Series Replacement Brackets

D4GS-N CSM_D4GS-N_DS_E_7_2

Features. Emergency Stop Switch A165E. Separate Construction with Smallest Class of Depth in the World. Safety Lock Prevents Misuse

Model Number Legend (Completely Assembled)... Shipped as a set which includes the Operation Unit, Lamp (lighted models only), and Switch. 4.

DIN Track Terminal Blocks with Screw Terminals XW5T

Model Number Structure

D4NS. Safety-door Switch. Multi-contact, Labor-saving, Environment-friendly, Next-generation Safety-door Switch. Model Number Structure

Smile 11 RA/-B Smile 12 RF/-G Reset button

Ordering Information. Specifications. Motor Time Switch H2F-WM. Accessories (Order Separately) Time Specifications. Ratings

XW2R-COM. Common Terminals X W 2R - P D - COM. Space-saving and less wiring work of power supply wiring are achieved. Application Example

Ratings 1 A at 125 VAC 1 A at 30 VDC LED indicator Without indicator With indicator Without indicator With indicator Actuator

DIN Track Terminal Blocks with Screw Terminals XW5T

Tina 11A Connection block

DIN Track Terminal Blocks with Screw Terminals

Better Productivity by Standstill and Low-speed Monitoring

2NC (slow-action) Direct. Model. opening

Smile 41 Push-button box with/without emergency stop

A22E. Emergency Stop Switch (22-dia./25-dia.) Install in 22-dia. or 25-dia. Panel Cutout. Model Number Structure L M 24A 01

Dimension A. Dimension B

Tina 4A Connection block

Tina 10A/B/C Adaptor unit

A22LK CSM_A22LK_DS_E_6_2

EStrong-series Emergency Stop

Sense7-series Non-contact coded safety switch

D4BL. Guard Lock Safety-door Switch

Input terminals Isolation method Zero cross function Operation indicator Alarm output Applicable load (See note.) Model

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

FMC-1/2 Tina Muting unit

Safety Limit Switch

A16. Separate Construction with Cylindrical 16-dia. Body. Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia.

Safety Guard Switching Unit G9SX-GS

D4NH. Safety-door Hinge Switch. Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment

D4BL. Guard Lock Safety-door Switch

E bracket (see note 1) SPST-NO G7L-1A-TJ-CB G7L-1A-BJ-CB DPST-NO G7L-2A-T-CB G7L-2A-B-CB

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

LED Signal Towers. Pre-assembled and pre-cabled in different aperture to highlight the processes. Features/Unique selling proposition

D4NH CSM_D4NH_DS_E_7_1

A16. Separate Construction with Cylindrical 16-dia. Body. Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia.

Eden AS-i Proximity safety sensor

D4BL. Guard Lock Safety-door Switch. Die-cast aluminum body Key holding force of 700 N. Model Number Structure. Model Number Legend Switch D4BL - K

Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia.) Model

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

A4EG CSM_A4EG_DS_E_6_1

MKey9-series Safety Interlock Switch with Guard Locking

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

Redundancy Unit. Model Number Structure. Ordering Information. Model Number Legend. New Product. S8VK-R Series name

2 to 25 A, 100 to 240 VAC G3PF-225B-STB Compact slotted

CSM_D4N-_R_DS_E_6_1

Please note! This model of Eden is obsolete and has been replaced by Eden DYN. Original instructions Eden Non-contact safety sensor

Pushbutton Switches 30-mm Pushbutton Switches Universal Design. Emphasis on Color Coding, Workability, and Safety.

Cylindrical photoelectric sensors in M18 plastic or brass housings. Performance and portfolio variety. Metal *1 90 Optics AC power supply *2

M T R - 24D - P

A22. Install in 22-dia. or 25-dia. Panel Cutout (When Using a Ring) Pushbutton Switch (Cylindrical 22/25-dia.) List of Models

Model Number Structure. Characteristics. Model Number Legend. Soft Starter. Applicable Motors. Accessories

Lighted Pushbutton Switch

D4NS/D4NS-SK. Safety-door Switch. Multi-contact, Labor-saving, Environment-friendly, Nextgeneration. Model Number Structure. Model Number Legend

A L - J R M - 24D - 2

Knox Safety and process lock

A22E. Model Number Structure. Emergency Stop Switch. Model Number Legend. Completely Assembled. Install in 22-dia. or 25-dia.

Features. Emergency Stop Switch A22E. Install in 22-dia. or 25-dia. Panel Cutout. Safety Lock Mechanism to Prevent Misuse.

High-power Solid State Relays G3PH

PRODUCT SPECIFICATION. Stack Lights. Series.

A165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm

Solid State Relays G3NA. Model Number Structure. Model Number Legend

PRODUCT SPECIFICATION. Foot Switches. Series.

Small-diameter Proximity Sensor

A22E. Model Number Structure. Emergency Stop Switch. Model Number Legend. Completely Assembled. Install in 22-dia. or 25-dia.

DirectWire Vehicle Information 2012 Subaru WRX - North America. Page 1 of 5. Wiring Information. Page 1 of 5

1,000 M min. (at 500 VDC)

Ordering Information. Motor Time Switch H2F-D. Accessories (Order Separately) ON/OFF Control 48 Times per Day in 15-min Increments

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

TABLE OF CONTENTS. 8.3 Online Sensor Specifications. Series TS (Models TS1, TSP, TSH, TSL,TSF, TSB1, TSB2) According to Electromatic factory procedure

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

A22TK Key-type Selector Switch with Direct Opening Mechanism

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

D4NL. Guard Lock Safety-door Switch. Best-selling Guard Lock Safety-door Switch Available in Several Compact, Multi-contact Models

Emergency Stop Pushbutton Switches (22-dia. or 25-dia.) A22E/A22NE-P

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

Microcontroller Unit (MCU) LCD Hour Meters/Counters. LM Series. Datasheet

HATCHGRIP Installation Instructions/Operation and Maintenance Manual

Authorised Distributors:- Intech Systems Chennai Pvt. Ltd, Chennai Ph: Mob: Fax:

DirectWire Vehicle Information 2016 Subaru Impreza (Smart Key) - North America. Page 1 of 4. Wiring Information. Page 1 of 4

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

Miniature Limit Switches

CAUTION 7.0 WARRANTY CONTENTS. 1.0 Overview... 2

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

TYPICAL INDICATOR ORDERING EXAMPLE. Lamps. Incandescent Lamp Used with Solid Cap 05 5-volt volt. Incandescent or Neon Lamp Used with Insert Cap

MODEL 908. Read Instructions Carefully! Fuel Gauge CURTIS INSTRUMENTS, INC.

A Member of the. Integrated Metering Technologies

Safety Interlock Switches

Transcription:

Indicator (Square) CSM DS_E_3_2 Indicator Series with Square 40-mm Body Same type of Indicator as those in the A3S-series Pushbutton Switch Easy panel mounting from the front and simple lamp replacement without tools. Refer to Safety Precautions for All Pushbutton Switches/ Indicators and Safety Precautions for the A3S. List of Models Indicators Appearance Model Rectangular J Square A Specifications: Refer to page 9. Dimensions: Refer to page 10. Accessories: Refer to the A3S. 1

Model Number Structure Model Number Legend...The model numbers used to order sets of Units are illustrated below. One set comprises the, Lamp, and Socket Unit. For information on combinations, refer to Ordering Information on page 3. (2) (3) (4) (1) 1-24E R... J - 90A 3-24E RW...Short-axis 2-split screen Left Right R (Red) W (White) (1) Shape of Symbol Shape J Rectangular A Square (2) Screen Pattern Illumination-only models Symbol 1 Screen pattern Short-axis 2-split screen (3) Lighting Method LED-lighted Models Symbol Rated voltage 05E 5 VDC 12E 12 VDC 24E 24 VDC (4) Color of Operation Unit LED-lighted Models Symbol R Y G W Color Red Yellow Green White 3 (rectangular models only) Models with colored illumination can be ordered individually. Refer to page 4 for details. Colored Illumination Unlit Lit Incandescent Lamp-lighted Models Symbol Rated voltage 06 6 V 14 14 V 28 28 V Incandescent Lamp-lighted Models Symbol R Y G A R Color Red Yellow Green Blue Red White Color The built-in LED is colored. Number of Built-in LEDs and Incandescent Lamp Model Screen pattern LED Incandescent lamp 2 1 J Short-axis 2-split screen 2 2 A 1 1 Type Structure of Split-screen Operation Unit Color cap Legend plate * Dispersion plate (rectangular models and square models) Short-axis 2-split screen (rectangular models only) Light-separation plate (2-split screen models only) LED/incandescent lamp holder * The square A with incandescent lamp does not include a legend plate. 2

Ordering Information Ordering as a Set...The model numbers used to order sets of Units are given in the following tables. One set comprises the Operation Unit, Lamp, and Socket Unit. Rectangular Models (1) Short-axis 2-split screen (1) (2) J Lighting method LED Incandescent lamp * Incandescent lamp only Item Indicator Operation Unit color symbol 5 VDC J-90A1-05E@ Enter the desired color symbol into the box in the model 12 VDC J-90A1-12E@ number. R (red) 24 VDC 6 V 14 V J-90A1-24E@ J-90A1-06@ J-90A1-14@ Y (yellow) G (green) A (blue) * W (white) 28 V J-90A1-28@ Short-axis 2-split screen Item Lighting method Indicator LED 24 VDC J-90A3-24E@@ Incandescent lamp 28 V J-90A3-28@@ Operation Unit color symbol Enter the desired color symbol into the box in the model number. R (red) Y (yellow) G (green) A (blue) * W (white) * Incandescent lamp only Square M2KA Square Models A Item Lighting method Indicator 5 VDC A-90A1-05E@ LED 12 VDC A-90A1-12E@ 24 VDC A-90A1-24E@ 6 V A-90A1-06@ Incandescent lamp 14 V A-90A1-14@ 28 V A-90A1-28@ * Incandescent lamp only. Operation Unit color symbol Enter the desired color symbol into the box in the model number. R (red) Y (yellow) G (green) A (blue) * W (white) Specifications: Refer to page 9. Dimensions: Refer to page 10. Accessories: Refer to the A3S. 3

Ordering Information Illumination-Only and Colored Illumination for LED-lighted Models With illumination-only models, the surface is the same color whether the LED is lit or not. Example: Red illumination Unlit White Lit Red Color cap (red) Legend plate (transparent) Dispersion plate (milk-white) Lamp holder LED (red) With colored illumination models, the surface is white when the LED is not lit and colored when it is lit. Example: Red illumination Unlit White Lit Red Color cap (red) Legend plate (transparent) Dispersion plate (milk-white) Lamp holder LED (red) Ordering...For colored illumination, order the, Lamp, and Socket Unit individually as shown in the following table. LED Socket Unit Rectangular J-5801 2-split screen Square A-5801 Select the LED color to be illuminated when lit (red, yellow, or green) from page 8. Select from the Switches on page 8. Rectangular J-5921 4

Ordering Information Ordering Individually... s, Lamps, and Socket Units can be ordered separately. Combinations that are not available as sets can be created using individual Units. Also, store the parts as spares for maintenance and repairs. Ordering...Specify a model number from the following page. LED Lamp-lighted Models Incandescent Lamp-lighted Models Lamp (LED) Lamp (Incandescent Lamp) DC-only SLL-@@E@ Standard lamp: SLL-@@ Socket Unit Socket Unit Ordering set combinations: Refer to page 3. Specifications: Refer to page 9. Dimensions: Refer to page 10. Accessories: Refer to the A3S. 5

Ordering Information Ordering Individually...s, Lamps, and Socket Units can be ordered separately. Combinations that are not available as sets <LED-lighted Models> (LED is not built in.) can be created using individual Units. Also, store the parts as spares for maintenance and repairs. Rectangular Models (2 LEDs) Square Models (1 LED) Appearance Screen pattern color (transparent legend plate built in) (transparent legend plate built in) White J-5801 A-5801 Red J-5802 A-5802 Green J-5803 A-5803 Yellow J-5805 A-5805 White/red J-5901 White/green J-5902 Standard White/yellow J-5904 split screen Red/green J-5905 Red/yellow J-5907 Green/yellow J-5909 Red/white J-5911 2-split Green/white J-5912 screen * Reverse Yellow/white J-5914 split screen Green/red J-5915 Yellow/red J-5917 Yellow/green J-5919 White/white J-5921 One-color 2-split Red/red J-5922 screen Yellow/green J-5923 Yellow/yellow J-5925 * Two-split screen configurations are given with the OMRON surface of the case at the bottom. Ordering set combinations: Refer to page 3. Specifications: Refer to page 9. Dimensions: Refer to page 10. Accessories: Refer to the A3S. 6

Ordering Information Ordering Individually... s, Lamps, and Socket Units can be ordered separately. Combinations that are not available as sets can be created using individual Units. Also, store the parts as spares for maintenance and repairs. <Incandescent Lamp-lighted Models> (Incandescent Lamp is not built in.) Rectangular models Square models Appearance Screen pattern color (transparent legend plate built in) Legend plate not included. One lamp White J-5301 A-5301 Red J-5302 A-5302 Green J-5303 A-5303 Blue J-5304 A-5304 Yellow J-5305 A-5305 Two lamps White J-5321 Red J-5322 Green J-5323 Blue J-5324 Yellow J-5325 White/red J-5201 White/green J-5202 White/blue J-5203 White/yellow J-5204 Standard Red/green J-5205 split screen Red/blue J-5206 Red/yellow J-5207 Green/blue J-5208 Green/yellow J-5209 Blue/yellow J-5210 Red/white J-5211 Green/white J-5212 2-split Blue/white J-5213 screen * Yellow/white J-5214 Reverse Green/red J-5215 split screen Blue/red J-5216 Yellow/red J-5217 Blue/green J-5218 Yellow/green J-5219 Yellow/blue J-5220 White/white J-5221 One-color Red/red J-5222 2-split Green/green J-5223 screen Blue/blue J-5224 Yellow/yellow J-5225 * Two-split screen configurations are given with the OMRON surface of the case at the bottom. Ordering set combinations: Refer to page 3. Specifications: Refer to page 9. Dimensions: Refer to page 10. Accessories: Refer to the A3S. 7

Ordering Information Ordering Individually...s, Lamps, and Socket Units can be ordered separately. Combinations that are not available as sets Lamp LED can be created using individual Units. Also, store the parts as spares for maintenance and repairs. Operating voltage 5 VDC 12 VDC 24 VDC Color Red SLL-05ER Red SLL-12ER Red SLL-24ER Red Yellow SLL-05EY Yellow SLL-12EY Yellow SLL-24EY Yellow Green SLL-05EG Green SLL-12EG Green SLL-24EG Green White SLL-05EW White SLL-12EW White SLL-24EW White Note: The A3SJ (J) requires two LEDs for each Switch. The applicable lens color applies to illumination-only models. Incandescent Lamp Model (DC only) Applicable lens (color) Note: The low-voltage lamp is advantageous in terms of heat generation. Socket Unit (used for both incandescent lamps and LEDs) Model (DC only) Operating voltage Lamp type Standard lamp Low-power lamp 5 V SLL-06 SLL-06H 12 V SLL-14 SLL-14H 24 V SLL-28 SLL-28H Applicable lens (color) Model (DC only) Applicable lens (color) Appearance Rectangular models Square models Selection precautions Model J-8010 A-7010 Use the Socket Unit in combination with the same shape (rectangular or square) Accessories, Replacements, and Tools The accessories, replacements, and tools are also used with the A3S Pushbutton Switch. Refer to the A3S datasheet Ordering set combinations: Refer to page 3. Specifications: Refer to page 9. Dimensions: Refer to page 10. Accessories: Refer to the A3S. 8

Specifications Approved Standard Ratings UL (File No. E41515), CSA (File No. LR45258) LED: 24 VDC max. Incandescent lamp: 28 VAC/VDC,1.2 W max. Note: Certification has been obtained for the Indicator. For detailed information on individual products that have received certification, consult your supplier. Ratings Ambient operating temperature Ambient operating humidity Ambient storage temperature 10 to 50 C (with no icing or condensation) 35% to 85%RH 25 to 65 C (with no icing or condensation) LED and Incandescent Lamp Ratings LED for LED-lighted Models Type DC only Operating voltage Rated voltage Rated current Built-in limiting resistance 5 VDC ±5% 5 VDC 30 ma 39 Ω 12 VDC ±5% 12 VDC 15 ma 270 Ω 24 VDC ±5% 24 VDC 12.5 ma 1,300 Ω Incandescent Lamp Operating voltage Rated voltage Standard lamp Low-power lamp Rated current Rated current 12 VAC/VDC 14 VAC/VDC 80 ma 40 ma 24 VAC/VDC 28 VAC/VDC 40 ma 25 ma Nomenclature Structure Structure Color cap Legend plate Note: Not included for the A with incandescent lamp. Dispersion plate Lamp holder Rectangular Square Models Models (J) (A) Screen pattern Short-axis 2-split screen color LED White, red, green, yellow Incandescent Lamp White, red, green, yellow Lamp Socket Unit Lighting method LED Incandescent Lamp Note: The J is shown here as an example. 9

Dimensions (Unit: mm) Rectangular Models (J) OMRON logo 0.5 Square Models (A) OMRON logo 19.4 19.1 22±0.2 13.2 0.5 15.8±0.2 1.2 1.8 13.2 15.8±0.2 2.8 13.2 15.8±0.2 2.8 24±0.2 Terminal Arrangement Bottom View (All are shown with the OMRON logo facing down.) Rectangular Models (J) 4.2 1.8±0.1 32.5 40 Square Models (A) Tab terminal #110 4.2 1.8±0.1 32.5 40 Tab terminal #110 Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. Recommended panel thickness: 1 to 4 mm 0.5 LB LB 8.8 L L 8.8 19.1 1.5 2 Note: The arrangements given above are not indicated on the Socket Unit. Terminal connections (All are shown with the OMRON logo facing down.) Incandescent Lamp-lighted Models (The terminal arrangements are the same as for the LED-lighted models.) Model Type Incandescent Lamp LED Lamp Bottom View Top View Bottom View Top View Rectangular Models (J) LB LB LB LB Terminal arrangement Lighting block Terminal arrangement Lighting block Bottom View Top View Bottom View Top View Square Models (A) Terminal arrangement Lighting block Terminal arrangement Lighting block 10

Dimensions (Unit: mm) Panel Cutout J (If a Switch Guard or Seal Cover is to be used, refer to the panel cutout diagrams for the A3S.) Classification Mounting design Panel cutout Remarks Individual mounting, horizontal 24±0.2 22.4±0.2 Flange mount models Multiple mounting, horizontal Individual mounting, vertical 24±0.2 1 2 n 24n±0.5 Mount to Long Mounting Plate (A3SJ-3002) before use. 24n 1.6±0.2 22.4±0.2 Panel cutout spacing between rows of Units: 6 min. 3 min. Multiple mounting, vertical 24±0.2 1 2 n Mount to Long Mounting Plate (A3SJ-3002) before use. 22.4±0.2 17.8n±0.5 17.8n 1.6±0.2 Individual mounting, horizontal 19.8 29.7 26.9±0.2 Barrier mount models Multiple mounting, horizontal Individual mounting, vertical 19.8 26 23.5 1 2 n Mount to Long Mounting Plate (A3SJ-3002) before use. 25.3n +4.4 25.3n +1.6±0.2 22.4±0.2 20.7±0.2 Panel cutout spacing between rows of Units: 1.4 6 min. 4 min. (Dotted line indicates the position of each Mounting Barrier.) Note: If the panel is to be finished (e.g., coated), make sure that the panel meets the specified dimensions after the coating. A Flange mount models Barrier mount models Multiple mounting, vertical Note: If the panel is to be finished (e.g., coated), make sure that the panel meets the specified dimensions after the coating. Safety Precautions Mount to Long Mounting Plate (A3SJ-3002) before use. Classification Mounting design Panel cutout Remarks Panel cutout spacing between rows of Units: Individual mounting 3 min. Multiple mounting Individual mounting Multiple mounting 26 1 2 n 19.8 19.1n +4.4 19.1n +1.6±0.2 1 2 3 n 23.5 17.8n±0.5 19.8 1 2 3 n 19.1n + 4.4 Panel cutout spacing between rows of Units: (Dotted line indicates the position of each Mounting Barrier.) Refer to Safety Precautions for All Pushbutton Switches/Indicators and Safety Precautions for the A3S. 22.4±0.2 17.8n 1.6±0.2 20.7±0.2 6 min. 1.4 19.1n + 1.6±0.2 6 min. 4 min. 11

Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICUR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 2012.9 In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 2012 All Right Reserved.

Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: A-5802