Liquefied Gas Injector. Solution for the Sampling and Analysis of Liquefied Gases

Similar documents
The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector

Refinery Gas. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Beverage Grade Carbon Dioxide

C2, C3, C4 Monomer Analysis

Antek Gas Chromatography Products: A Guided Tour Through Industry

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector

S-PRO 3200 GC System for Sulfur Analysis

ANALYSIS AND MANAGEMENT OF GAS PROCESSES FROM REMOTE

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

Fast and Reliable Trace Gas Analysis Improved Detection Limits for the Agilent 490 Micro GC

GC Method Compliance and Large Valve Oven Application

White Paper. Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Introduction. Background Information

Sulfur Detection at ppb Levels in Light Hydrocarbon Streams

Dual Plasma Sulfur and Nitrogen Chemiluminescence Detectors. Unsurpassed Stability, Selectivity, and Sensitivity for your GC Analysis

DANI Transformer Oil Gas Analyzer

TURN-KEY ANALYZERS SUPERIOR PETROCHEMICAL SOLUTIONS SOLUTIONS SPECIAL APPLICATIONS

Experience the Difference

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph

The Stability of Sulfur Compounds, Low Molecular Weight Gases, and VOCs in Four Air Sample Bag Materials

High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System

Oxygenates in Fuels Analysis Solutions From Trace Levels to Ethanol Fuels

Dual Channel Simulated Distillation of Carbon and Sulfur with the Agilent 7890A GC and 355 Sulfur Chemiluminescence Detector

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application

gc applications Hydrocarbons C1-C5 Paraffins Hydrocarbons, Sulfur Gases C1-C2 Hydrocarbons Gases

PRODUCT SPECIFICATION. Product Specification Crystal 9000 Gas Chromatograph. Chromatec Crystal Laboratory Gas Chromatography System

Live Crude Oil Volatility

ANTEK APPLICATED Turn-Key GC solutions

Method Development for Capillary GC Systems. Slide 1

Analysis of Petroleum Fractions by ASTM D2887

Phillips 66 Pipeline LLC. Blue Pipeline Natural Gas Liquids Specifications

Application Note. Authors. Abstract. Energy & Chemicals

performance productivity reliability

ANNEX 2, REFERENCE FUELS

Technical Procedure for Gas Chromatography (GC-FID)

Analytical and Testing Instruments for the HPI Market Shimadzu s Total Solutions for the Hydrocarbon Processing Industry

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis

Module8:Engine Fuels and Their Effects on Emissions Lecture 36:Hydrocarbon Fuels and Quality Requirements FUELS AND EFFECTS ON ENGINE EMISSIONS

Agilent Portfolio. Luca Godina. Technical Marketing Specialist GC-GCMS

ANNEX 3 REFERENCE FUELS. Parameter Unit Limits (1) Test method Minimum Maximum Research octane number, RON

TSHR 6000 series TN/TS/TX analyzer

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS

Simulated Distillation Analyzers, Software, Standards, Consumables, Training

Live Crude Oil Volatility

ABB MEASUREMENT & ANALYTICS ANALYTICAL MEASUREMENT. PGC1000 Meeting the needs of NGL plants

breakthrough versatility

Using the PSD for Backflushing on the Agilent 8890 GC System

Fausto Munari e Andrea Cadoppi ThermoFisher - Italy

Application Note. Abstract. Authors. Environmental Analysis

Softening point by Ring & Ball. Density and relative density of liquids by Hubbart pycnometer

HIGH PRESSURE SUPERCRITICAL CARBON DIOXIDE EFFICIENCY IN REMOVING HYDROCARBON MACHINE COOLANTS FROM METAL COUPONS AND COMPONENTS PARTS

Siemens AG, 2008 MAXUM II

Rosemount 570 Natural Gas Chromatograph

Model 8610C Gas Chromatograph. GC Chassis Types ECD PID FID / DELCD FPD. Mounts up to Six Detectors and Five Injectors

Agilent and ASTM. Update on Recent Activities. Page 1

Operation and Applications of Differential Flow Modulation

THC Heated FID 3-300A

Refinery Support from the R&D Laboratory Perspective using Fast & Micro Gas Chromatography

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Zeolite Catalyst. Methanol. Propylene. Petrochemical Research & Technology پژوهش و فناوري پتروشیمی

CERTIFICATE OF ACCREDITATION

Oil & Gas. From exploration to distribution. Week 3 V19 Refining Processes (Part 1) Jean-Luc Monsavoir. W3V19 - Refining Processes1 p.

Distillation process of Crude oil

GC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585

Ultra Clean Gas Filters Reference Guide ULTRA CLEAN GAS FILTERS

6. Lone Star NGL Mont Belvieu LP E/P Mix November 16, Lone Star NGL Mont Belvieu LP Refinery Grade Butane November 29, 2012

CHEVRON PHILLIPS CHEMICAL PIPELINE COMPANY LLC PETROCHEMICAL PRODUCTS (AS DEFINED HEREIN)

Specifications for Refrigerants

Application. Gas Chromatography June 1995

Group-Type Analysis (PiPNA) in Diesel and Jet Fuel by Flow Modulated GCxGC FID.

Fast Simulated Distillation Based on Agilent 6890N Gas Chromatograph Application

Hydrocracking of atmospheric distillable residue of Mongolian oil

Free and Total Glycerol in B100 Biodiesel by Gas Chromatography According to Methods EN and ASTM D6584

INTEREST OF HPTLC FOR FOSSIL DERIVED PRODUCTS ANALYSIS : A SIMPLE APPROACH TO HYDROCARBON GROUP TYPE ANALYSIS

Supply of Services for Detailed OEB Crude Assay Analysis

Agilent Multimode Inlet for Gas Chromatography

Large Volume Injection of Polycyclic Aromatic Hydrocarbons

Standard Test Method for Sulfur in the Analysis Sample of Coal and Coke Using High-Temperature Tube Furnace Combustion

DETERMINATION OF N-BUTANOL AND ISOBUTANOL IN GASOLINE USING GAS CHROMATOGRAPHY (GC-FID)

Impact of GC Parameters on The Separation Part 2: Choice of Column Internal Diameter

Jaap de Zeeuw Restek Middelburg, The Netherlands. Copyrights: Restek Corporation

ANALYSIS OF GASOLINE RANGE HYDROCARBONS ON BP1-PONA

APPLICATION OF SOLID PHASE MICROEXTRACTION (SPME) IN PROFILING HYDROCARBONS IN OIL SPILL CASES

High-Temperature Simulated Distillation System Based on the 6890N GC Application

PSF REFORMULATED FUEL REPORT OF REFORMULATED GASOLINE UTILIZING RAW FUEL FROM FCC REFINERY UNIT

Thermal Conversion of Fossil and Renewable Feedstocks

Appendix A.1 Calculations of Engine Exhaust Gas Composition...9

Detection of Volatile Organic Compounds in Gasoline and Diesel Using the znose Edward J. Staples, Electronic Sensor Technology

Irving Oil Whitegate Refinery Limited

GC Instruments GC Columns GC Accessories

Quantification and Characterization of Sulfur in Low-Sulfur Reformulated Gasolines by GC-ICP-MS Application

GAS CHROMATOGRAPHY LGC-A1 SERIES

Why do we study about Fuel for IC Engine? Because fuel properties affect the combustion process in engine and its operation

Extended fuel flexibility capabilities of the SGT-700 DLE combustion system

Annex no. 1 of Accreditation Certificate no. LI 333 from

RESOLUTION MEPC.272(69) (Adopted on 22 April 2016) AMENDMENTS TO THE NOX TECHNICAL CODE 2008 NITROGEN OXIDES FROM MARINE DIESEL ENGINES

Molecular Sieves Application Guide for the Natural Gas Industry Molecular Sieve Molecular Sieve Recommendations

Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI)

Performing ASTM 6584 free and total glycerin in BioDiesel using an SRI Gas Chromatograph and PeakSimple software

Transcription:

Liquefied Gas Injector Solution for the Sampling and Analysis of Liquefied Gases

Safe and Representative Sampling of Liquefied Gases The analysis of impurities and contaminants in liquefied gases is an analytical challenge. The contaminants and impurities are high boiling or unstable components having a high molecular weight, which complicates the sample introduction. Their adsorption on vaporizers, injection valves and transfer lines enlarges the discrimination, adsorption, and fractionation effects. Current test methods are labor intensive and present a safety risk due to the required evaporation of the large volumes of liquefied gas. Da Vinci Laboratory Solutions (DVLS) developed an alternative and fast gas chromatographic method which features a direct injection of the liquefied gases that eliminates the need for sample evaporation: the Liquefied Gas Injector. Liquefied Gas Injector The direct injection approach of the Liquefied Gas Injector includes the proven fuel direct injection technique used by the automotive industry to inject fuel into the automotive engine combustion chamber. The LGI is connected to a standard GC injector needle, which is inserted into a GC large volume on-column injection system. Solenoid activation transfers the pressurized sample through the needle directly on-column. A sliding device moves the needle downwards for the injection and upwards for purging. Pressure Station To allow a representative sample injection a Pressure Station is used to keep the sample in a liquid phase during the injection. The sample cylinder is installed using quick connectors. For liquid samples the Pressure Station adds high pressure Nitrogen to the sample cylinder and controls the outlet pressure and flow. Optionally the Pressure Station can also be configured for gas samples by including a vaporizer to control the sample evaporation after injection. The waste sample is vented to a central waste system to ensure laboratory safety. 2 Boosting laboratory efficiency

Analysis of Liquefied Gases The Liquefied Gas Injector (LGI) is introduced in 2010 and has been standardized as ASTM D7756 and EN 16423 for the analysis of residues in liquefied petroleum gases by gas chromatography. Adapting the hardware setup allows to extend the analysis of oily residues in LPG to a wider application range. Key Benefits Safe injection of liquefied gases The direct injection approach of the LGI is based on a proven fuel direct injection technique used by the automotive industry which eliminates the need for sample evaporation Representative sampling The pressure station ensures that the sample remains in the liquid phase during the injection process Proven technology Since its introduction in 2010 the LGI has been successfully used by a global installed base of leading oil refineries. Wide application range The LGI determines hydrocarbon composition, impurities, contaminants and sulfur compounds in liquefied gases and nitrogen, carbon dioxide, hydrogen sulfide and hydrocarbons in unstabilized gas condensate Accurate and fast performance Several case studies demonstrate an excellent and fast performance of the LGI The Liquefed Gas Injector allows a direct & safe injection of liquefied gases into a GC column The sample container is easily & safely installed on the front side using quick connectors The controller box drives the injection cycling. Pressure station allows to inject a representative and repeatable amount of the sample www.davinci-ls.com 3

Application Range The DVLS Liquefied Gas Injector offers laboratories a proven GC standard for the following applications: Oily residues and light contaminants in LPG (ASTM D7756, EN 16423) Hydrocarbon composition of LPG (ASTM D 2163, ISO 7941) Sulfur compounds in liquefied petroleum gases Desulfurization additives in LPG: DIPA, MEA & DEA Inhibitors, additives and Dimers in Butadiene: ACN, ρtbc, Butadiene Dimer Nitrogen, carbon dioxide, hydrogen sulfide and hydrocarbons in unstabilized gas condensate Oily Residues Analysis in LPG (ASTM D7756/EN 16423) The ASTM D7756/EN 16423 application uses the Liquefied Gas Injector (LGI). The sample is injected under a constant pressure into a Sulfinert coated stainless steel retention gap. The retention gap is connected to a non-polar retaining pre-column, with an exit for flushing the LPG matrix. After matrix venting, the valve is closed and the flow is directed to an analytical column for the separation of the various contaminants present in LPG. Specifications: Analysis time < 30 minutes Oily residue analysis range of 10-600 mg/kg LOD individual components < 1 ppm The chromatographic analysis after the sample introduction is based on boiling point separation of the oily residues and contaminants. The total residue is quantified using area summation of the components in the range of C10 to C40. The result is reported in parts per million (w/w) of residue in LPG. 4 Boosting laboratory efficiency

Dual Analysis of Oily Residues in LPG (ASTM D7756/EN 16423) and Hydrocarbon Composition of LPG (ASTM D2163 & ISO 7941) The LGI method for determining oily residue in C3 and C4 streams complies with ASTM D7756 and EN 16423. Adding an external oven with a special valve configuration to a high pressure liquid sampling application extends the single analysis to a dual analysis of both the oily residue and the hydrocarbon composition of LPG at the same time from the same sample cylinder. The column for the compositional analysis was installed in an external oven, enabling running both the temperature program for the D7756 application and the compositional analysis simultaneously. Analytical results demonstrate that the repeatability complies very well with both ASTM D7756 and ASTM D2163. Component Avg. Area Counts oily residue ethane propane propylene i-butane n-butene t-2-butene butene-1 i-butene c-2 -butene i-pentane n-pentane 4935.9 8.5 29415.9 71.7 2080.6 11117.7 83.7 42.4 38.1 59.6 123.4 1028.0 Stdev 77.6 0.2 488.3 1.1 31.6 166.9 1.3 0.7 0.5 0.9 1.8 14.7 % RSD 1.6 1.8 1.7 1.5 1.5 1.5 1.5 1.6 1.2 1.5 1.5 1.4 Maximum difference between the calculated concentrations of the 7 analyses 1.343 ppm 0.009 0.088 0.0004 0.0119 0.074 0.001 0.01 ASTM Repeatability 5.159 ppm 0.0001 0.777 0.020 0.077 0.223 0.023 0.057 Analysis of Amines in LPG To quantify Amines in LPG an LGI system is setup according to ASTM D7756. Analytical tests demonstrate that the LGI repeatability is better than 2% relative and the lower detection limit is far below 1 ppm. Solvent MTBE DIPA Dodecane Hexadecane www.davinci-ls.com 5

Analysis of Sulfur Compounds in Liquefied Gases Several methods are available for the quantification of individual sulfur compounds, that use a GC configured with a sulfur specific detector and a gas or liquid sampling valve for the sample introduction. The LGI method offers several advantages over the sample introduction through a valve as the direct injection avoids contact of the sample with transfer lines, vaporizers or valves. FPD signal = red FID signal = blue The LGI application is configured with a sulfur specific Flame Photometric Detector (FPD) for the analysis of sulfur compounds in liquefied Propane, Butane and liquid Pentane. Sulfur Conc. % RSD LOQ LOD COS 0.51 0.6 0.18 0.05 FPD signal = red FID signal = blue When using an PFPD or SCD detector an even higher sensitivity can be achieved. The LGI-GC technique combined with a sulfur specific detector offers a powerful tool for sulfur control of liquefied petroleum gas samples and liquid pentane samples. Sulfur Conc. % RSD LOQ LOD DMS 0.34 0.3 0.19 0.06 DMDS 0.09 4.3 0.19 0.06 6 Boosting laboratory efficiency

Analysis of Inhibitors, Additives and Impurities in Butadiene The LGI application dedicated to the analysis of ACN, NMP, VCH and ptbc consists of a GC configured with the LGI, an on-column injection port, a solvent vapor exit and a Flame Ionization (FID) detection. Analytical tests proof that ptbc can be very well separated from the C3/C4 matrix of LPG. To measure ACN in the C3/C4 matrix a WAX type column is used. Test results demonstrate that this polar column is able to separate ACN and VCH very well, even from a C5 matrix. 5.380 - ACN 6.648 - VCH 10.171 - ptbc Component LOQ (mg/kg) LOD (mg/kg) RSD % ptbc 0.078 0.023 0.6 ACN 0.045 0.013 0.4 VCH 0.011 0.003 0.3 Controlled handling of Butadiene cylinders, in combination with on-column GC injection, reduces health and safety risks for analysts involved in Butadiene quality control. NMP Pentanes Toluene Component LOD (mg/kg) RSD % NMP < 1 < 2 www.davinci-ls.com 7

Analysis of N 2, CO 2, H 2 S and Hydrocarbons in Unstabilized Gas Condensate The design of the LGI allows liquefied gas analysis with pressures up to 80 bar and requires a single GC run for the analysis of Nitrogen, Carbon dioxide, Hydrogen sulfide and C1-C36+ hydrocarbons in high pressure unstabilized gas condensate. The sample is kept under pressure by pressurizing the sample cylinder with water or using a piston cylinder. By applying a two channel system, only one single injection is required. Nitrogen, Carbon dioxide, Hydrogen sulfide, Methane, Ethane and Propane are analyzed using a TCD. C4 up to C36+ are analyzed using an FID. Repeatable results of 1.5% RSD of the normalized area% are found. Toluene Benzene Da Vinci Laboratory Solutions B.V. Visiting address: Cairostraat 10 3047 BC Rotterdam The Netherlands Postal address: P.O. Box 12103 3004 GC Rotterdam The Netherlands T +31 (0)10 258 1870 F +31 (0)10 258 1879 E solutions@davinci-ls.com I www.davinci-ls.com Service Office Visiting address: Da Vinci Laboratory Solutions Chemelot Campus Building G122.03.0.26 Urmonderbaan 22 6167 RD Geleen (Gate2) The Netherlands C 4 s C 5 s FID C 27 Da Vinci Caricom Laboratory Solutions Visiting address: Zonnebloemstraat 80a Paramaribo Suriname T +597 49 11 29 F +597 49 51 91 E info@davincicaricom.com N 2 CH 4 CO 2 C 2 H 6 H2 S C 3 H 8 www.davinci-ls.com