Valor 2000 Series Instruction Manual

Similar documents
Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

Catapult 1000 Series Instruction Manual

Defender 3000 Series Base Instruction Manual

Navigator TM Series Balances Instruction Manual

Ohaus ES Series Bench Scale

Scout TM Series Balances - SKX Instruction Manual

Compact Scales. Software Revision V1.25 & above

Scout Series Balances - SPX Instruction Manual

Washdo. wn Scale Base

V-D2425 and V-D2440 Digital Clock

HARVARD TRIP BALANCE Series 1400 and 1500 Instruction Manual

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013)

Adam Equipment WBW & WBW-M SERIES. (P.N , Revision A2, November 2011)

SFA275 USER MANUAL PLEASE READ THIS USER MANUAL COMPLETELY BEFORE OPERATING THIS UNIT AND RETAIN THIS BOOKLET FOR FUTURE REFERENCE

MONOPRICE. Power Cache 220 Solar Power Generator. User's Manual P/N 15278

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

GRUNDFOS INSTRUCTIONS. Grundfos ALPHA Installation and operating instructions

BATTERY CHARGER INSTRUCTION MANUAL. model no. ACG112CL

Balanzas de la gama Scout TM SJX Series Manual de Instrucciones

Quick Guide. brite Advanced Retail scale

Price Computing Scale D Series Operation Manual

2800 OPERATING INSTRUCTIONS

SPC Series. Digital Scale. Operation Manual

User Guide. Digital Shipping Scale S150


SSP-Series Portable Balances Operation Manual

Adam Equipment. CB Balance. (P.N Revision B1, Apr 2014)

User s Manual ATTILA THE ANKYLOSAURUS TM VTech Printed in China US

User s Manual HORNS THE TRICERATOPS TM VTech Printed in China US

Owner's Manual. For latest instructions please go to

Learn & Discover Driver TM

P Volt Charger Each sold separately and subject to availability.

Please read and understand all precautions prior to use.

MARINER MODEL WPS12 WATERPROOF DIGITAL PORTION SCALE OWNER S MANUAL

LED Recessed Troffer Retrofit Kit

User s Manual Chase on the Case Cruiser

Owner's Manual. For latest instructions please go to

Powerware Vdc Extended Battery Cabinet User s Guide.

OWNER S MANUAL Please read and understand all precautions prior to use.

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

Owner's Manual. For latest instructions please go to

POWERWARE User s Guide VA.

P OWER CUBE PLEASE READ BEFORE OPERATING THIS EQUIPMENT. Powerful Universal Portable Charger T M

INSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1107

AC / 65 W M PLEASE READ BEFORE OPERATING THIS EQUIPMENT.

MQ4C-24/6485 WIRELESS INDOOR/OUTDOOR QUAD-COPTER

P

User s Manual VTech Printed In China US CA Manual new.indd /6/6 10:41:57

SKU# LC54225 Please retain these instructions for future reference. Adult assembly required.

Back-Up Sensor System

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

User s Manual Pups to the Rescue Driver

User s Manual AKUNA THE VELOCIRAPTOR VTech Printed in China US

Bear s Baby Laptop TM

Thermometer models 02023/02028/02053/02054

Owner's Manual. mycharge name and logo are registered trademarks of RFA Brands RFA Brands. All Rights Reserved. Patent Pending.

LIPSTICK CHARGER POWERFUL UNIVERSAL PORTABLE CHARGER OPERATING INSTRUCTIONS

DC 5000 Series Crane Scale Instruction Manual

ITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance

User Manual Pocket Pro, Pro + ph

Model 3400KL / 3401KL / 3400KG / 3400KG-C Digital Wet Diaper / Lap Sponge / Organ Scale

T500 Series. Applications. Features. Applicable Literature. Non-Digital, On/Off Thermostat General Instructions

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

Thermometer models 02023, 02028, 02029

AeraMax Pro AM IV. Please read these instructions before use. Do not discard: keep for future reference.

OPERATING INSTRUCTIONS

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

WIRELESS SMART CHARGING PAD OPERATING INSTRUCTIONS PLEASE READ BEFORE OPERATING THIS EQUIPMENT

Bluetooth Smart Speed/Cadence Sensor Instruction Manual

02/15/01. Powerware User s Guide VA.

ECONOMY COUNTING SCALE OPERATION & SERVICE MANUAL

SERVICE MANUAL. STARTER Portable Meter ST300 ST300C ST300D ST400D. Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ (973)

453X Series. Application. Features. Two-Position Damper Actuator General Instructions

Thermometer models / 00831A

USER GUIDE. c--' c-' Remote. for #SED-10R

Adam Equipment CPW COMPACT SCALE

Wireless Thermometer model 00380

(((temporary title page))) Please read these instructions before using your FS/GS HUSKY FS/GS USER LEAFLET

CLASSIC II Portable Braking System

PORT-A-WEIGH CRANE SCALES

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

Operating Instructions

Owners Manual for TPMS plus GPS

Model 594KL Digital Chair Scale

Instruction Manual. SmarTire LF Initiator Tool. PN: Revision 1.2. Copyright 2006 SmarTire Systems Inc.

F261 Series Fluid Flow Switches

USE AND CARE GUIDE 7000 LUMEN TWIN HEAD LED WORKLIGHT WITH TRIPOD

SHINE 3000 POWERFUL UNIVERSAL PORTABLE CHARGER OPERATING INSTRUCTIONS

Thermometer model 00826

Press the buttons for fun sounds and music! fisher-price.com

Thermistor Thermometer MODEL NO

Go! Go! Smart Friends

6. Electrical. 7. Settings. 8. Quick

Wireless Key Tracker. Locate Lost Keys instantly

Feature Overview. For more information: or call toll free at

Wireless Thermometer model 00782W

Instruction Manual 03

Features that make the Jarv TANK power bank remarkable!

RJH-4/6046. Wireless 3.5 Channel Mega Helicopter. (Instruction Manual)

V2700Z OWNER S GUIDE.

Transcription:

99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com TM Valor 2000 Series Instruction Manual

Valor 2000 Series Scales EN-1 1. INTRODUCTION This manual contains installation, operation and maintenance instructions for the TM Valor 2000 Series Scales. Please read the manual completely before using the scale. 1.1 Safety Precautions Please follow these safety precautions: Verify that the AC Adapter input voltage matches the local AC power supply. Do not immerse the scale in water or other liquids. Do not operate the scale in hostile environments. Do not drop loads on the platform. Do not place the scale upside down on the pan. Service should only be performed by authorized personnel. Disconnect the scale from the power supply when cleaning. 1.2 Controls Figure 1-1. Controls. Figure 1-2. Rear Display.

EN-2 Valor 2000 Series Scales TABLE 1-1. CONTROL FUNCTIONS. Button Primary Function (Short Press) Secondary Function (Long Press) Menu Function (Short Press) ON/ 0/T Turns scale ON. If scale is On: Sets zero. Performs a tare operation. Off Turns scale off. Yes Accepts the current setting on the display. UNITS Changes the weighing Unit. Menu Enter the User menu. No Advances to the next menu or menu item. Rejects the current setting on the display and advances to the next available setting. 2. INSTALLATION 2.1 Package Contents Scale Pan Power Adapter Instruction Manual Warranty Card 2.2 Location Use the scale on a firm, steady surface. Avoid locations with excessive air current, vibrations, heat sources, or rapid temperature changes. 2.3 Leveling the Scale Adjust the leveling feet so the bubble is centered in the circle.

Valor 2000 Series Scales EN-3 2.4 Power Level Bubble Adjustable Feet Figure 2-1. Leveling the Scale. IMPORTANT: To relieve any internal pressure and allow proper airflow inside the scale, unscrew the two rear leveling feet slightly, then level the scale accordingly. When cleaning the scale, the rear leveling feet must be screwed in tightly to avoid entry of water inside the scale. 2.4.1 AC Power The AC adapter (included) may be used to power the scale when battery power is not available. Remove the rubber seal in the back. Connect the AC adapter plug to the input jack. Then plug the AC adapter into a properly grounded power outlet. NOTE: To prevent water ingress during use, insert rubber Seal into the input jack recess. Seal Figure 2-2. Power Connection and Sealing.

EN-4 Valor 2000 Series Scales 2.4.2 Battery Power The scale can be operated on the internal rechargeable battery when AC power is not available. The scale will automatically switch to battery operation if there is a power failure or the power cord is removed. Before using the scale for the first time, the battery should be fully charged for up to 12 hours. During charging, the battery Indicator displays the charge level (see Table 2-1), and the scale can be operated during charging. The battery is protected against over charging and the scale can remain connected to the AC power line. TABLE 2-1. BATTERY CHARGE STATUS. Charge Status Indication Light Charge level Off Fully Charged Flashing Green 70 100 % Flashing Yellow 40 70 % Flashing Red 0 40 % The scale can operate for approximately 60 hours on a fully charged battery. During battery operation, the battery Indicator displays the battery status (see Table 2-2). TABLE 2-2. BATTERY CAPACITY STATUS. Charge Status Indication Light Capacity Remaining Solid Green 70 100 % Solid Yellow 40 70 % Solid Red 10 40 % Flashing Red 0 10 % Flashing Red, Lo bat Requires recharge; Accuracy not guaranteed NOTE: Charging the scale must only be performed in a dry environment. Install the rubber seal securely to ensure the scale is protected when operating in a wet environment. CAUTION: Battery is to be replaced only by an authorized Ohaus service dealer. Risk of explosion can occur if replaced with the wrong type or connected improperly. Dispose of the lead acid battery according to local laws and regulations.

Valor 2000 Series Scales EN-5 2.5 Initial Calibration When the scale is operated for the first time, a Span calibration is recommended to ensure accurate weighing results. Before performing the calibration, be sure to have the appropriate calibration weight. Refer to section 4.2 for Span calibration procedures. 3. OPERATION 3.1 Turning Scale On/Off To turn the scale on, press the ON/ 0/T Off button. The scale performs a display test, momentarily displays the model/software version, and then enters the active weighing mode. To turn the scale off, press and hold ON/ 0/T Off button until OFF is displayed. 3.2 Zero Operation Press the ON/ 0/T Off button to zero the weight display. The scale must be stable to accept zero operation. 3.3 Manual Tare Place a container on the weighing pan, then press ON/ 0/T Off. The display will show a net value of 0. To clear the Tare value, press ON/ 0/T Off with the pan empty. 3.4 Changing Units of Measure Press the UNITS/Menu button to display the next available measuring unit. Only measuring units enabled in the Unit Menu will be displayed (refer to Section 4.4). 4. SETTINGS The Menu allows the user to customize scale settings. 4.1 Menu Navigation Press and hold UNITS/Menu button until MENU is displayed, then release it. Press Yes to enter the displayed menu or press No to advance to the next menu. When viewing the menu setting, press Yes to accept the setting, or press No to change it, then press Yes to accept the setting and move to the next menu. When End is displayed, press Yes to exit the menu.

EN-6 Valor 2000 Series Scales 4.2 CAL Menu SPAN Perform Span calibration Yes or No. LIN Perform Linearity calibration Yes or No. NOTE: Ensure the appropriate calibration masses are available before beginning calibration (see Table 4-1). Ensure that the scale is level and stable during the entire calibration process. Calibration is unavailable with LFT set to On. Allow the scale to warm up for approximately 5 minutes after stabilizing to room temperature. To abort calibration, power off the scale. TABLE 4-1. CALIBRATION WEIGHTS. Model Span Calibration weight (kg) User selectable Linearity Calibration weight (kg) Fixed V21PW3 1, 2, 3 2, 3 V21PW6 2, 4, 6 4, 6 V21PW15 5, 10, 15 10, 15 4.2.1 Span Calibration Span Calibration uses two points to adjust the scale. The first point is the zero value where there is no weight on the scale. The second point is the Span value where a calibration mass is placed on the scale. When SPAN is displayed, press the Yes button to access the Span Calibration menu item. The display flashes 0. With no weight on the scale, press the Yes button to establish the zero point. The display shows --C-- while the zero point is established.

Valor 2000 Series Scales EN-7 The display flashes the span calibration point. Place the specified weight on the scale and press the Yes button. To choose a different span point, repeatedly press the No button to increment the selections. When the desired value is displayed, place the specified weight on the scale and press the Yes button. The display shows --C-- while the span point is established. If span calibration was successful, done is displayed and the scale exits to the active weighing mode and displays the actual weight value. 4.2.2 Linearity Calibration Linearity calibration uses 3 calibration points. The first calibration point is established with no weight on the scale. The second calibration point is established at approximately half capacity. The third calibration point is established at capacity. The Linearity calibration points are fixed and cannot be altered by the user during the calibration procedure. When LIN is displayed, press the Yes button to access the Linearity Calibration menu item. The display flashes 0. With no weight on the scale, press the Yes button to establish the zero point. The display shows --C-- while the zero point is established. The display flashes the mid calibration point. Place the specified weight on the scale and press the Yes button. The display shows --C-- while the mid point is established.

EN-8 Valor 2000 Series Scales The display flashes the full calibration point. Place the specified weight on the scale and press the Yes button. The display shows --C-- while the full calibration point is established. If linearity calibration was successful, done is displayed and the scale exits to the active weighing mode and displays the actual weight value. 4.3 RES Menu RESOLUTION Set the resolution to LO (low) or HI (high). 4.4 UNIT Menu KILOGRAM UNIT Set kilograms ON or OFF. When kg is lit, press the Yes button to access the ON or OFF setting, then press No to choose ON or OFF, then Yes to accept the setting. GRAM UNIT Set grams ON or OFF. When g is lit, press the Yes button to access the ON or OFF setting, then press No to choose ON or OFF, then Yes to accept the setting. POUND UNIT Set pounds ON or OFF. When lb is lit, press the Yes button to access the ON or OFF setting, then press No to choose ON or OFF, then Yes to accept the setting. OUNCE UNIT Set ounces ON or OFF. When oz is lit, press the Yes button to access the ON or OFF setting, then press No to choose ON or OFF, then Yes to accept the setting.

Valor 2000 Series Scales EN-9 4.5 A OFF Menu AUTO SHUT OFF Set the automatic shut off to 5, 10, 15 minutes (shut off after 5 minutes, etc.) or OFF (scale stays on). 4.6 FILTR Menu FILTERING LEVEL Set the filter level to LO (low), MEd (medium), or HI (high). 4.7 AZT Menu AUTO ZERO TRACKING RANGE Set the automatic zero tracking range to OFF, 0.5d, 1d, 3d (divisions). 4.8 LFT Menu LEGAL FOR TRADE (LFT) MODE Set the legal for trade status to ON or OFF. 4.9 END End menu item. 5. LEGAL FOR TRADE 5.1 Settings Enter the menu to verify the settings and perform a calibration as explained in Section 4.2. Set the LFT menu to ON. NOTE: When LFT is set to ON, the following menu settings cannot be accessed/changed: Calibration, Resolution, Unit, AZT, LFT. To regain access to the locked menu settings, remove the small cover on the bottom of the scale. Then during power up press and hold the recessed lock switch momentarily until zero is displayed.

EN-10 Valor 2000 Series Scales Lock Switch Figure 5-1. Lock Switch. When accessing the bottom of the scale, avoid placing the scale upside down on the pan or sub-platform. Place the scale on its side. 5.2 Verification Before this product can be used in a trade approved application, it must be inspected in accordance with local weights and measures regulations. It is the responsibility of the purchaser to ensure that all pertinent legal requirements are met. Please contact your local weights and measures office for further details. 5.3 Sealing The weights and measures official can apply a wire or paper security seal as shown below. SEAL SEAL Figure 5-2. Sealing. 6. MAINTENANCE CAUTION: to avoid possible water entry, before cleaning the scale: Turn off the scale, remove the AC adapter and install the rubber seal securely. Screw in the two rear leveling feet tightly. When the scale is put back into operation, remember to loosen the two rear feet to allow proper airflow inside the scale.

Valor 2000 Series Scales EN-11 6.1 Cleaning The housing may be cleaned with a cloth dampened with a mild detergent if necessary. Do not use solvents, chemicals, alcohol, ammonia or abrasives to clean the housing or control panels. 6.2 Troubleshooting The following table lists common problems and possible causes and remedies. If the problem persists, contact Ohaus or your authorized dealer. TABLE 6-1. TROUBLESHOOTING. Symptom Possible Cause(s) Remedy Scale will not turn on Poor accuracy Unable to calibrate Cannot display weight in desired weighing unit No power to scale Battery power used up Improper calibration Unstable environment Internal pressure build-up LFT Menu set to ON Unstable environment Incorrect calibration mass Weighing unit not enabled Verify connections and voltage. Connect power and charge the battery Perform calibration Move scale to suitable location Relieve internal pressure by loosening rear leveling feet Set LFT menu to OFF (see section 5.1) Move the scale to suitable location Use correct calibration mass Enter menu and enable unit Cannot change menu settings LFT Menu set to ON Set LFT menu to OFF (see section 5.1) Scale displays Lo bat Battery is discharged Connect power and charge the battery Battery fails to charge fully Battery is defective Have battery replaced by authorized service dealer Err 1 Weight on pan exceeds capacity Remove weight from the pan Err 2 Underload limit exceeded Pan was removed prior to power on Install pan and re-zero Err 9, Err 21 Factory data corrupted Contact Ohaus or an authorized service agent

EN-12 Valor 2000 Series Scales 6.3 Service Information If the troubleshooting section does not resolve or describe your problem, contact your authorized Ohaus service agent. For service assistance or technical support in the United States call toll-free 1-800-526-0659 between 8.00 AM and 5:00 PM EST. An Ohaus product service specialist will be available to provide assistance. Outside the USA, please visit our web site, www.ohaus.com to locate the Ohaus office nearest you. 7. TECHNICAL DATA The technical data is valid under the following ambient conditions: Ambient temperature: 0 C to 40 C Relative humidity: 10% to 95% relative humidity, non-condensing Height above sea level: Up to 2000 m Operability is assured at ambient temperatures between 0 C and 40 C 7.1 Specifications TABLE 7-1. SPECIFICATIONS. Model V21PW3 V21PW6 V21PW15 3 kg x 0.0005 kg 6 kg x 0.001 kg 15 kg x 0.002 kg Capacity x Readability 3000 g x 0.5 g 6000 g x 1 g 15000 g x 2 g (max x d non-approved) 6 lb x 0.001 lb 15 lb x 0.002 lb 30 lb x 0.005 lb 96 oz x 0.02 oz 240 oz x 0.05 oz 480 oz x 0.1 oz Maximum displayed resolution 1:6000 1:6000 1:7500 Capacity x Readability (max x e approved) 3 kg x 0.001 kg 3000 g x 1 g 6 lb x 0.002 lb 96 oz x 0.05 oz 6 kg x 0.002 kg 6000 g x 2 g 15 lb x 0.005 lb 240 oz x 0.1 oz 15 kg x 0.005 kg 15000 g x 5 g 30 lb x 0.01 lb 480 oz x 0.2 oz Approved resolution 1:3000 1:3000 1:3000 Repeatability +0.001 kg +0.002 kg +0.005 kg Linearity +0.001 kg +0.002 kg +0.005 kg Weighing Units kg, g, lb, oz Tare range To capacity by subtraction Stabilization Time 2 seconds Power Requirements 9-12 VDC 0.7A AC Adapter (supplied) Internal rechargeable sealed lead-acid battery Display 2x red LED (front and rear) 6-digit 7-segment, 15mm / 0.6 in characters Keypad 2-button mechanical keys Ingress Protection IP65 Pan Size (mm / in) 233 x 184 / 9.2 x 7.2 Typical Battery life 60 hours with 12 hour recharge time Operating temperature range 0 C to 40 C Net Weight (kg / lb) 3.5 / 7.8 Shipping Weight (kg / lb) 4.3/ 9.3

Valor 2000 Series Scales EN-13 7.2. Drawings and Dimensions 249 mm (9.8 in.) 229 mm (9.0 in.) 233 mm (9.2 in.) 184 mm (7.2 in.) 142 mm (5.6 in.) Figure 7-1. Valor 2000 Series Overall Dimensions.

EN-14 Valor 2000 Series Scales 7.3. Compliance Compliance to the following standards is indicated by the corresponding mark on the product. Mark Standard This product conforms to the EMC directive 2004/108/EC and the Low Voltage Directive 2006/95/EC. The complete declaration of Conformity is available from Ohaus Corporation AS/NZS4251.1 Emission; AS/NZS4252.1 Immunity NSF/ANSI 169 2005 NSF/ANSI /3-A 14159-1 - 2002 Important notice for verified weighing instruments Weighing Instruments verified at the place of manufacture bear one of the preceding mark on the packing label and the green M (metrology) sticker on the descriptive plate. They may be put into service immediately. Weighing Instruments to be verified in two stages have no green M (metrology) on the descriptive plate and bear one of the preceding identification mark on the packing label. The second stage of the initial verification must be carried out by the approved service organization of the authorized representative within the EC or by the national weight & measures (W+M) authorities. The first stage of the initial verification has been carried out at the manufacturers work. It comprises all tests according to the adopted European standard EN 45501:1992, paragraph 8.2.2. If national regulations limit the validity period of the verification, the user of the weighing instrument must strictly observe the re-verification period and inform the respective W+M authorities.

Valor 2000 Series Scales EN-15 Disposal In conformance with the European Directive 2002/96 EC on Waste Electrical and Electronic Equipment (WEEE) this device may not be disposed of in domestic waste. This also applies to countries outside the EU, per their specific requirements. Please dispose of this product in accordance with local regulations at the collecting point specified for electrical and electronic equipment. If you have any questions, please contact the responsible authority or the distributor from which you purchased this device. Should this device be passed on to other parties (for private or professional use), the content of this regulation must also be related. Thank you for your contribution to environmental protection. FCC Note This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. ISO 9001 Registration In 1994, Ohaus Corporation, USA, was awarded a certificate of registration to ISO 9001 by Bureau Veritus Quality International (BVQI), confirming that the Ohaus quality management system is compliant with the ISO 9001 standard s requirements. On May 15, 2003, Ohaus Corporation, USA, was re-registered to the ISO 9001:2000 standard.

EN-16 Valor 2000 Series Scales LIMITED WARRANTY Ohaus products are warranted against defects in materials and workmanship from the date of delivery through the duration of the warranty period. During the warranty period Ohaus will repair, or, at its option, replace any component(s) that proves to be defective at no charge, provided that the product is returned, freight prepaid, to Ohaus. This warranty does not apply if the product has been damaged by accident or misuse, exposed to radioactive or corrosive materials, has foreign material penetrating to the inside of the product, or as a result of service or modification by other than Ohaus. In lieu of a properly returned warranty registration card, the warranty period shall begin on the date of shipment to the authorized dealer. No other express or implied warranty is given by Ohaus Corporation. Ohaus Corporation shall not be liable for any consequential damages. As warranty legislation differs from state to state and country to country, please contact Ohaus or your local Ohaus dealer for further details. Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com