ULT800. TEE Transducer Leakage Current Tester. Users Guide

Similar documents
Go to to register your product and find more information.

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

DPM1B. Operators Manual. Pneumatic Transducer Tester

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

Automatic Pressure Calibrator. 3-Year Limited Warranty. See the Users Manual for the full warranty.

DPM4. Parameter Tester. Users Manual

233 True-rms Remote Display Digital Multimeter Safety Information

2-Year Limited Warranty. See the Users Manual for the full warranty.

3-Year Limited Warranty. See the Users Manual for the full warranty.

362 Clamp Meter. Users Manual

Ti200, Ti300, Ti400, Ti450, Ti480 Thermal Imagers

Ti300 PRO, Ti400 PRO, Ti450 PRO, Ti450 SF6, Ti480 PRO Thermal Imagers

190M. Medical ScopeMeter. Safety Information

80 Series V Digital Multimeter Safety Information

1000FLT. Users Manual. Fluorescent Light Tester

i3000s/i2000 Flex AC Current Probe

323/324/325 Clamp Meter

302+/303 Clamp Meter. Users Manual

Megohmmeter Test Probe

365 Detachable Jaw True-rms Clamp Meter

Users Manual. Phase Rotation Indicator

362 Clamp Meter. Users Manual

373 Clamp Meter. Users Manual

Calibration Manual. Detachable Jaw True-rms Clamp Meter

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

SLA Battery Capacity Analyzer

ProSim 4. Vital Signs Simulator. Getting Started

BK BK A BK MA BK MA BK J93 MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

i400s Calibration Information Introduction

BroadBand PowerShield. 20 AHr Battery. User Manual

Phase Sequence Tester


H2, HV2R, HV2G Rotary Laser Levels

Model P772 Conductivity Meter. User Manual

700G Series. Users Manual. Pressure Gauge

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual


Model 3400KL / 3401KL / 3400KG / 3400KG-C Digital Wet Diaper / Lap Sponge / Organ Scale

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Model G14SD Vapor Management System

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

707Ex. Users Manual. ma Calibrator

PY-11 Voltage & Continuity Tester

CTFRP Series Power Supplies

BK BK J93 MA BK MA BK MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

KMP Insulation-Continuity Tester. Users Manual

Water Level Meter + Temperature

AXD 530 MicroManometer

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

1 AMP CURRENT SOURCE

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

User's Manual. Earth Ground Resistance Tester. Model Introduction

User s Manual Power Supply IM E. 5th Edition

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

Spy pocket Jeepmeter ope rati ng instructions

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

HTR-202 INSTRUCTION MANUAL. Portable Digital Height Rod. Befour, Inc. 102 Progress Drive Saukville, WI 53080

OPERATION AND MAINTENANCE

Temperature Probe, Battery (installed), Instruction Sheet, Quick Reference Card and Warranty Card.

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

KSZ 10B Current Probe Calibrator. Instruction Manual

Model 1693, 1694 Switching DC Power Supply

SPC Series. Digital Scale. Operation Manual

Model 2053 Conductivity Meter Instruction Manual

Defender 3000 Series Base Instruction Manual

AIR VELOCITY METER ALNOR MODEL AVM410 AIRFLOW INSTRUMENTS MODEL TA410

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Thermocouple Thermometer Models

Switching DC Power Supply

Users Manual. Airflow Meter

Instruction manual. High voltage insulation resistance tester KEW3121B/3122B

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

PD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL

User Manual Stealth s Power Tilt

712 RTD Calibrator. Instruction Sheet. Introduction

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

TIME-10 Process Control Stopwatch

DCell Suction. Model DM Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

INSTRUCTION MANUAL. 12-Station HD Shop 12V Portable Battery Charger

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

KSZ 100B Current Probe Calibrator. Instruction Manual

MICROMANOMETER ALNOR MODEL AXD610 AIRFLOW INSTRUMENTS MODEL PVM610

SECULIFE PS100 PATIENT SIMULATOR

IAQ-CALC TM Indoor Air Quality Meter

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

Table of Contents Title Page No.

T2 Tester. Calibration Information. Introduction. Safety Information

Powerware Vdc Extended Battery Cabinet User s Guide.

600 Amp Battery Jumper with Air Compressor

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

Cordless Sweeper. OWNER S MANUAL Model: CFT Volt DC. Made Exclusively for ALDI Inc. Batavia, IL.,

Users Manual. MegOhmMeter

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

Instruction Manual AVTM for. Strip Chart Recorder Catalog Nos and

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

PVI 60KW, PVI 82KW, PVI 95KW

Transcription:

ULT800 TEE Transducer Leakage Current Tester Users Guide PN 2461434 August 2005, Rev.2, 11/13 2006, 2013 Fluke Corporation, All rights reserved. Printed in USA All product names are trademarks of their respective companies.

Warranty and Product Support Fluke Biomedical warrants this instrument against defects in materials and workmanship for one full year from the date of original purchase. During the warranty period, we will repair or, at our option, replace at no charge a product that proves to be defective, provided you return the product, shipping prepaid, to Fluke Biomedical. This warranty does not apply if the product has been damaged by accident or misuse or as the result of service or modification by other than Fluke Biomedical. IN NO EVENT SHALL FLUKE BIOMEDICAL BE LIABLE FOR CONSEQUENTIAL DAMAGES. Only serialized products and their accessory items (those products and items bearing a distinct serial number tag) are covered under this one year warranty. PHYSICAL DAMAGE CAUSED BY MISUSE OR PHYSICAL ABUSE IS NOT COVERED UNDER THE WARRANTY. Items such as cables and nonserialized modules are not covered under this warranty. Recalibration of instruments is not covered under the warranty. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state, province to province, or country to country. This warranty is limited to repairing the instrument to Fluke Biomedical s specifications. Warranty Disclaimer Should you elect to have your instrument serviced and/or calibrated by someone other than Fluke Biomedical, please be advised that the original warranty covering your product becomes void when the tamper-resistant Quality Seal is removed or broken without proper factory authorization. We strongly recommend, therefore, that you send your instrument to Fluke Biomedical for factory service and calibration, especially during the original warranty period.

Notices All Rights Reserved Copyright 2013, Fluke Biomedical. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language without the written permission of Fluke Biomedical. Copyright Release Fluke Biomedical agrees to a limited copyright release that allows you to reproduce manuals and other printed materials for use in service training programs and other technical publications. If you would like other reproductions or distributions, submit a written request to Fluke Biomedical. Unpacking and Inspection Follow standard receiving practices upon receipt of the instrument. Check the shipping carton for damage. If damage is found, stop unpacking the instrument. Notify the carrier and ask for an agent to be present while the instrument is unpacked. There are no special unpacking instructions, but be careful not to damage the instrument when unpacking it. Inspect the instrument for physical damage such as bent or broken parts, dents, or scratches. Technical Support For application support or answers to technical questions, either email techservices@flukebiomedical.com or call 1-800- 850-4608 or 1-440-248-9300. In Europe, email: techsupport.emea@flukebiomedical.com or call +31-40-2965314. Claims Our routine method of shipment is via common carrier, FOB origin. Upon delivery, if physical damage is found, retain all packing materials in their original condition and contact the carrier immediately to file a claim. If the instrument is delivered in good physical condition but does not operate within specifications, or if there are any other problems not caused by shipping damage, please contact Fluke Biomedical or your local sales representative.

Returns and Repairs Return Procedure All items being returned (including all warranty-claim shipments) must be sent freight-prepaid to our factory location. When you return an instrument to Fluke Biomedical, we recommend using United Parcel Service, Federal Express, or Air Parcel Post. We also recommend that you insure your shipment for its actual replacement cost. Fluke Biomedical will not be responsible for lost shipments or instruments that are received in damaged condition due to improper packaging or handling. Use the original carton and packaging material for shipment. If they are not available, we recommend the following guide for repackaging: Use a double walled carton of sufficient strength for the weight being shipped. Use heavy paper or cardboard to protect all instrument surfaces. Use nonabrasive material around all projecting parts. Use at least four inches of tightly packed, industry-approved, shockabsorbent material around the instrument. Returns for partial refund/credit: Every product returned for refund/credit must be accompanied by a Return Material Authorization (RMA) number, obtained from our Order Entry Group at 1-800- 648-7952 or 1-425-446-6945. Repair and calibration: To find the nearest service center, goto www.flukebiomedical.com/service or In the U.S.A.: Cleveland Calibration Lab Tel: 1-800-850-4606 x2564 Email: globalcal@flukebiomedical.com Everett Calibration Lab Tel: 1-888-99 FLUKE (1-888-993-5853) Email: service.status@fluke.com In Europe, Middle East, and Africa: Eindhoven Calibration Lab Tel: +31-40-2675300 Email: ServiceDesk@fluke.com In Asia: Everett Calibration Lab Tel: +425-446-6945 Email: service.international@fluke.com To ensure the accuracy of the Product is maintained at a high level, Fluke Biomedical recommends the product be calibrated at least once every 12 months. Calibration must be done by qualified personnel. Contact your local Fluke Biomedical representative for calibration.

Certification This instrument was thoroughly tested and inspected. It was found to meet Fluke Biomedical s manufacturing specifications when it was shipped from the factory. Calibration measurements are traceable to the National Institute of Standards and Technology (NIST). Devices for which there are no NIST calibration standards are measured against in-house performance standards using accepted test procedures. WARNING Unauthorized user modifications or application beyond the published specifications may result in electrical shock hazards or improper operation. Fluke Biomedical will not be responsible for any injuries sustained due to unauthorized equipment modifications. Restrictions and Liabilities Information in this document is subject to change and does not represent a commitment by Fluke Biomedical. Changes made to the information in this document will be incorporated in new editions of the publication. No responsibility is assumed by Fluke Biomedical for the use or reliability of software or equipment that is not supplied by Fluke Biomedical, or by its affiliated dealers. Manufacturing Location The ULT800 Ultrasound Transducer Leakage Current Tester is manufactured in Everett, WA, U.S.A.

Table of Contents Title Introduction... 1 Safety Information... 1 Symbols... 2 Key Features... 3 Controls and Indicators... 4 Specifications... 6 Using the ULT800... 7 Checking the Battery... 11 Checking Solution Conductivity... 11 Testing for Transducer Leakage Current... 12 Maintenance... 12 Cleaning... 13 Battery... 14 Calibration... 15 Accessories... 16 Page i

ULT800 Users Guide ii

List of Tables Table Title Page 1. Symbols... 2 2. Controls and Indicators... 5 3. Accessories... 16 List of Figures Figure Title Page 1. Controls and Indicators... 4 2. Disinfection Basin Test Setup... 9 3. Disinfection/Storage Tube Setup... 10 iii

ULT800 Users Guide iv

Introduction The ULT800 TEE Transducer Leakage Current Tester measures the leakage current of ultrasound transducers independent of their ultrasound systems. Use the hand-held, battery-operated instrument during the routine transducer cleaning procedure conducted between patients. Safety Information A Warning identifies conditions and procedures that are dangerous to the user. A Caution identifies conditions and procedures that can cause damage to the Product or the equipment under test. Warning To prevent possible electric shock, fire, or personal injury: Read all safety Information before you use the Product. Use the Product only as specified, or the protection supplied by the Product can be compromised. Remove the batteries if the Product is not used for an extended period of time, or if stored in temperatures above 50 C. If the batteries are not removed, battery leakage can damage the Product. The battery door must be closed and locked before you operate the Product. Replace the batteries when the low battery indicator shows to prevent incorrect measurements. Carefully read all instructions. Do not touch voltages >30 V ac rms, 42 V ac peak, or 60 V dc. Do not use and disable the Product if it is damaged. Do not use the Product if it operates incorrectly. Examine the case before you use the Product. Look for cracks or missing plastic. Carefully look at the insulation around the terminals. Use this Product indoors only. 1

ULT800 Users Guide Do not use the Product around explosive gas, vapor, or in damp or wet environments. Symbols Table 1 is a list of symbols used on the Product and in this Users Guide. Table 1. Symbols Symbol Description Important information. Refer to manual. Hazardous Voltage Conforms to European Union directives Conforms to relevant North American Safety Standards. Conforms to relevant Australian EMC requirements Conforms to relevant Australian EMC standards Standby - On Battery Conforms to relevant South Korean EMC Standards. This product complies with the WEEE Directive (2002/96/EC) marking requirements. The affixed label indicates that you must not discard this electrical/electronic product in domestic household waste. Product Category: With reference to the equipment types in the WEEE Directive Annex I, this product is classed as category 9 "Monitoring and Control Instrumentation" product. Do not dispose of this product as unsorted municipal waste. Go to Fluke s website for recycling information. In addition to verifying that the ultrasound transducers are safe for patient use, the ULT800 makes it possible to reduce expensive repairs. Identifying transducers that exceed safe leakage currents early may allow for repairs to be made before a transducer becomes non-repairable. 2

Key Features Ultrasound Transducer Leakage Current Tester Key Features Hand-held instrument Stand-alone operation Direct measurement of leakage current Pass/Fail display of test results Battery operation for safety Independent of 120 or 240 V ac systems Built-in self-test circuit Auto shut off to conserve battery 3

ULT800 Users Guide Controls and Indicators Input connectors are interchangeable and provide for inputting an ultrasound transducer adapter and the dual conductivity electrode. Refer to Figure 1 and Table 2 for complete control and indicator descriptions. Biomedical ULT800 TEE TRANSDUCER LEAKAGE CURRENT TESTER READY PASS FAIL LOW BAT LEAKAGE CONDUCTIVITY ON TEST INSTRUCTIONS: 1. Connect the transducer and the adapters to the ULT 800. 2. Press the ON/TEST button and wait for the READY light. 3. Select CONDUCTIVITY and press the ON/TEST Button- Wait for the PASS light. 4. Select LEAKAGE and press the ON/TEST button againobserve PASS or FAIL light. If test fails, DO NOT USE TRANSDUCER. Refer to the user s manual. Figure 1. Controls and Indicators ecy10f.eps 4

Ultrasound Transducer Leakage Current Tester Controls and Indicators Table 2. Controls and Indicators Item Description READY PASS FAIL LOW BAT LEAKAGE/CONDUCTIVITY SWITCH ON/TEST BUTTON BATTERY COMPARTMENT Glows amber when the self-test procedure completes (approx. 8 sec.). The ULT800 is then ready for testing. Glows green when either the Conductivity Test or Leakage Test passes. Glows red when either the Conductivity Test or the Leakage Test fails. Pulses red when the Leakage Test results in less than 20 μa, indicating a possible open circuit condition with invalid test results. Flashes red to indicate that the battery requires replacement. Selects the test to perform. Turns the ULT800 on and initiates the selected test. (not shown): Holds a 9-volt alkaline battery. The instrument automatically powers off if you do not perform a test within 12 seconds. 5

ULT800 Users Guide Specifications Power... 9 V Alkaline Battery No. of Measurements... Approx. 1000 measurements on a single battery Conductivity... Pass limit is >250 μa ±5 % Leakage... Pass limit is <185 μa ±5 % and >20 μa ±5 μa Dimensions... 6.6 in x 3.7 in x 1.5 in (17 cm x 19 cm 4 cm) Weight... 12 oz (340 g) Temperature Operation... 15 C to 40 C Storage... 15 C to 65 C Relative Humidity... 90 % max. Altitude... 2000 m IP Rating... IEC 60529: IP20 Safety... IEC 61010-1: Pollution Degree 2 Electromagnetic Environment... IEC 61326-1: Basic Emissions Classification... IEC CISPR 11: Group 1, Class A. Group 1 have intentionally generated and/or use conductively coupled radiofrequency energy which is necessary for the internal functioning of the equipment itself. Class A equipment is suitable for use in non-domestic locations and/or directly connected to a low-voltage power supply network. Electromagnetic Compatibility... Applies to use in Korea only.class A: Equipment (Industrial Broadcasting & Communication Equipment) [1] [1] This product meets requirements for industrial (Class A) electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and is not to be used in homes. 6

Using the ULT800 Ultrasound Transducer Leakage Current Tester Using the ULT800 Warning To avoid personal injury, do not touch the dual conductivity electrode rods. Voltage is present on the rods during a test. Inspect the conductivity probe for damaged insulation or exposed metal. To avoid personal injury, replace a damaged conductivity probe before using. Caution To avoid damage to the transducer, observe the immersion levels. Do not immerse or allow the cable or connector of a transducer to become wet. The ULT800 TEE Transducer Leakage Current Tester is a portable, self-contained, battery-operated device. It measures the leakage current of the devices attached to its connectors. The ULT800 applies 120 V ac, 60 Hz to devices placed in a conductive bath (basin or storage tube). The ULT800 measures the current and compares the results to an internal threshold. The instrument displays the results as a PASS or FAIL indication. It also performs an internal self-calibration on each measurement cycle. Connect the transducer to be tested to the ULT800 via a unique adapter. The ULT800 performs the measurement with the transducer immersed in either the cleaning solution or saline. To insure that the leakage current test is accurate, first test the conductivity of the fluid. A special dual element probe also connected to the ULT800 tests the conductivity of the fluid. A green PASS light or a red FAIL light indicates the results of the conductivity and leakage current tests. The ULT800 makes two types of measurements. The Leakage Test measures the current between the probe and the electrode. The Conductivity Test measures the conductivity of the bath solution between the two electrodes. 7

ULT800 Users Guide Figures 2 and 3 show some typical test setups. You can use other setups, as long as you observe the following rules: 1. Connect the ultrasound probe you are testing to the probe adapter. See the list of available adapters under Accessories. 2. Place the probe you are testing in a saline bath with the entire critical area of the probe fully immersed. 3. Place the dual electrode (Part No. 2392502 or 2392569) in the saline bath to a depth of at least one inch. 4. Plug the probe adapter and the electrode wire connectors into the ULT800. The connections are fully interchangeable. 8

Biomedical Ultrasound Transducer Leakage Current Tester Using the ULT800 Dual Conductivity Electrodes X ULT800 TEE TRANSDUCER LEAKAGE CURRENT TESTER Fluke ULT800 READY PASS FAIL LOW BAT LEAKAGE ON Transducer-Specific Adapter CONDUCTIVITY TEST INSTRUCTIONS: 1. Connect the transducer and the adapters to the ULT 800. 2. Press the ON/TEST button and wait for the READY light. 3. Select CONDUCTIVITY and press the ON/TEST Button- Wait for the PASS light. 4. Select LEAKAGE and press the ON/TEST button againobserve PASS or FAIL light. If test fails, DO NOT USE TRANSDUCER. Refer to the user s manual. Figure 2. Disinfection Basin Test Setup ecy02f.eps 9

Biomedical ULT800 Users Guide Transducer-Specific Adapter Fluke ULT800 X ULT800 TEE TRANSDUCER LEAKAGE CURRENT TESTER READY PASS FAIL LOW BAT LEAKAGE ON CONDUCTIVITY TEST INSTRUCTIONS: 1. Connect the transducer and the adapters to the ULT 800. 2. Press the ON/TEST button and wait for the READY light. 3. Select CONDUCTIVITY and press the ON/TEST Button- Wait for the PASS light. 4. Select LEAKAGE and press the ON/TEST button againobserve PASS or FAIL light. If test fails, DO NOT USE TRANSDUCER. Refer to the user s manual. Dual Conductivity Electrode with 600/213 Extenders Disinfection and Storage Tube Figure 3. Disinfection/Storage Tube Setup ecy03f.eps 10

Checking the Battery Ultrasound Transducer Leakage Current Tester Checking the Battery Note The LOW BAT light flashes red to indicate that the battery needs replacement. 1. Use the LEAKAGE/CONDUCTIVITY switch to select CONDUCTIVITY. 2. Press the ON/TEST button to turn on the ULT800. The self-check routine starts, calibrating the unit. All four LED indicators flash in sequence, continuing for five cycles. The READY light glows amber when the self-test routine completes with a successful battery test. Checking Solution Conductivity Note The LED indicating a test result remains on for 12 seconds. The ULT800 then powers off to conserve the battery. To resume testing, power on the ULT800, allow the selfcheck/battery test to complete, and then reinitiate the test. 1. Select CONDUCTIVITY. 2. Press the ON/TEST button to perform a measurement cycle. 3. At the end of the measurement cycle (two seconds), the LED indicates the results of the test. The green PASS light illuminates if the solution passed the Conductivity Test. The red FAIL light illuminates if the solution failed the Conductivity Test. Check that you have immersed the electrodes to a depth of at least 25 mm (1 inch) and that they are firmly connected to the ULT800, then retest. If the failure repeats, replace the solution and then retest. 11

ULT800 Users Guide Testing for Transducer Leakage Current Note Perform the Leakage Test only if the Conductivity Test passes. 1. Select LEAKAGE. 2. Press the ON/TEST button to perform a leakage measurement. The green PASS light illuminates if the transducer passed the leakage current test. The red FAIL light illuminates if the transducer failed the leakage current test. If there is less than 20 μa of leakage current, the red light pulses, indicating a possible open circuit condition with invalid test results. Maintenance Your ULT800 needs little maintenance or special care. However, treat it as a calibrated measuring instrument. Avoid dropping or other mechanical abuse that could cause a shift in the calibrated settings. Warning To prevent possible electrical shock, fire, or personal injury: Batteries contain hazardous chemicals that can cause burns or explode. If exposure to chemicals occurs, clean with water and get medical aid. Do not disassemble the battery. Do not disassemble or crush battery cells and battery packs. Do not keep cells or batteries in a container where the terminals can be shorted. Do not put battery cells and battery packs near heat or fire. Do not put in sunlight. 12

Ultrasound Transducer Leakage Current Tester Maintenance Do not operate the Product with covers removed or the case open. Hazardous voltage exposure is possible. Use only specified replacement parts. Have an approved technician repair the Product. For safe operation and maintenance of the Product: Repair the Product before use if the battery leaks. Do not short the battery terminals together. Keep cells and battery packs clean and dry. Clean dirty connectors with a dry, clean cloth. Cleaning Caution Do not put fluid on the Product surface. Fluid leakage into the electrical circuitry may cause the Product to fail. Caution Do not use spray cleaners on the Product. This can push fluid into the Product and cause electronic component damage. Clean the ULT800 occasionally; use a damp cloth and mild detergent. Take care to prevent the entrance of liquids. Wipe down the adapter cables with the same care. Inspect them for damage to and deterioration of the insulation. Check the connections for integrity. Keep transducer adapter clean and dry. 13

ULT800 Users Guide Battery Warning The 9-volt alkaline battery provided with the ULT800 may explode or leak if recharged, inserted improperly, disposed of in a fire, or mixed with different battery types. Dispose of the battery in accordance with any applicable state or local regulations. The ULT800 uses a standard 9-volt alkaline battery. The battery has a life expectancy of approximately 1000 measurements. Replace the battery yearly, regardless of its condition. 14

Ultrasound Transducer Leakage Current Tester Maintenance Calibration Warning Examine the calibration label on the back of the ULT800 prior to each use. Do not use a ULT800 with an expired calibration label. A ULT800 without a calibration label or with the anti-tamper case label broken is out of calibration. A ULT800 that is out of calibration can cause excessive leakage current exposure to the patient; risk of injury to the patient could result. Caution Avoid dropping the ULT800 or allowing other mechanical abuse that could cause a shift in the ULT800 s calibrated settings. The ULT800 requires yearly Fluke factory calibration, which uses appropriate tools and reference instruments that are traceable to the National Institute of Standards and Technology (NIST). Factory calibration provides a calibration sticker on the back of the ULT800 to verify that the calibration was performed. To locate a service center, visit the Fluke web site at www.fluke.com, or contact Fluke at service@fluke.com. Call from anywhere in the world at +1-425-446-5500 or call for service in the USA at 1-888-99-FLUKE (1-888-993-5853.) 15

ULT800 Users Guide Accessories Refer to Table 3 for a list of accessories for the ULT800. Available transducer-specific adapters are listed on Fluke Biomedical s web site. www.flukebiomedical.com/electrical safety analyzers/ult800. Table 3. Accessories Part Number Model Number Description 2392427 600/102FG Chassis ground probe, 8-foot coiled cord 2392502 600/212FG Dual conductivity electrode 2392525 600/214FG Hard-sided carrying case 2392533 600/215FG Conductivity cable 2392569 600/220FG Dual conductivity probe for use with Cidex 2032 tray. 16