Features. Structure. Safety Standards and CE Marking For -AWMU, -CWME, -SWM Type. Construction A ORIENTAL MOTOR GENERAL CATALOG

Similar documents
Electromagnetic. Brake Motors. Constant Speed Motors. Standard AC Motors A-109. Standard AC Motors Introduction. Brake Motors

Single Phase 110 Single Phase 115 Single Phase 220 Single Phase 230 Single Phase 230 Three Phase 200 Three Phase 200 Three Phase 220 Three Phase 230

Low-Speed. Constant Speed Motors. Standard AC Motors A-203. Standard AC Motors Introduction. Low-Speed Synchronous Motors.

US U. Speed Control Motors. Features. Safety Standards and CE Marking M o t o r. Product Number Code

SMK Series. Additional Information. Stepping Motors. Technical Reference F-1 General Information G-1. Motor & Driver Packages.

Reversible Motors. Standard AC Motors. Constant Speed Motors. Standard AC Motors C-75. Reversible Motors

Conforms to Power Supply Voltages in Asia Induction Motors, Reversible Motors, and Electromagnetic Brake Motors

C B Motors CB I W U. Clutch and Brake Motors. Features. Product Number Code. Construction A ORIENTAL MOTOR GENERAL CATALOG

AC Motor Systems US Series

Induction Motors. Standard AC Motors. Constant Speed Motors. Standard AC Motors C-19. Induction Motors

COMPONENT Type SS21-UL Type

US Series Single-Phase 110/115 VAC Single-Phase 220/230 VAC

Constant Speed Motors

Standard AC Motors. Single-Phase Induction Motors K Series. Three-Phase High-Efficiency Induction Motors. K S Series

Torque Motors 3 W, 6 W, 10 W, 20 W

Constant Speed Motors

Brushless DC Motor Systems AXU Series

Brushless DC Motor Systems AXU Series

K Series. Next-Generation Right-Angle Shaft Geared Motors. Compact Standard AC Motors

Brake Pack SB50W. Standard AC Motors A-143. Standard AC Motors Intro duction. Brake Pack. AC Speed Control Motors Inverter.

LS Linear Heads. Standard AC Motors A-259. Standard AC Motors Introduction. Induction Motors. Reversible Motors. Brake Motors.

Standard AC Motors C-9

ORIENTAL MOTOR CATALOGUE. Gearheads A-177. Features and Types A-178 Right-Angle Gearheads A-180. Standard AC Motors

Current. Starting Torque. Rated Torque Single-Phase Three-Phase

Provided Capacitor E: Single-Phase 220V/230V. Motor

RoHS-Compliant. Watertight, Dust-Resistant Motors FPW Series

Watertight, Dust-Resistant. Motors. Standard AC Motors A-207. Standard AC Motors Intro duction. Motors. AC Speed Control Motors Inverter.

Features and Types A-178 Right-Angle Gearheads A-180

Output Power W HP VAC Hz A Three-Phase Three-Phase

Rated Torque. Current. Starting Torque Single-Phase Three-Phase

Brushless DC Motor Systems FBL2 Series

Installation. Standard AC Motors. Standard AC Motors C-277. Installation. Introduction. Induction Motors. Reversible Motors

Installation. Standard AC Motors A-305. Standard AC Motors Introduction. Installation. Induction Motors. Reversible Motors.

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Right-Angle Gearheads

Standard AC Motors. Single-Phase Induction Motors. Series. Three-Phase High-Efficiency Induction Motors K S Series

BLH. 24 VDC Input 15W / 30W / 50W / 100W BLH

DC Input. Brushless Motors/AC Speed Control Motors D-117. Brushless Motors/AC Speed Control Motors D-117. BLH Series. Overview, Product Series

DC Input. Brushless Motors/AC Speed Control Motors D-89. Brushless Motors/AC Speed Control Motors D-89. BLH Series. Overview, Product Series

HBL Series HBL 5 40 K - GN HBL 5 60 N - 5. Features. Product Number Code A ORIENTAL MOTOR GENERAL CATALOG

AXH Series. Brushless Motor and Driver Package. Features

How to Read Gearhead Specifications Gearheads are shown for both AC standard motors and Speed Control Systems. Gearmotor Torque Table (Example)

Brushless Motors BLE Series. Features

Standard AC Motors E-75

BLU Series. RoHS-Compliant. Brushless DC Motor and Driver Package. Features

AC Motor Systems. Speed Control Systems B-137. Speed Control Systems Introduction. BHF Series FE200 ES01/ US Series

Standard AC Motors. Structure of Standard AC Motors. Brake Mechanism of Reversible Motors. Structure of an Electromagnetic Brake

FE100/FE200. AC Speed Control Motors. Features

FE100/FE200. Inverter

RoHS-Compliant Brushless Motor Systems BLF Series. Features

DC MOTOR INDEX DC MOTOR FEATURES W ( 60mm) W ( 80mm) W ( 80mm) W ( 90mm) W ( 90mm) 227.

RoHS-Compliant. Brushless DC Motor and Driver Package BX Series

F-1. Technical Reference. Motor and Fan Sizing... F-2. Standard AC Motors... F-12. Speed Control Systems... F-22. Stepping Motors...

LS Linear Heads. Standard AC Motors. Standard AC Motors C-247. Introduction. Induction Motors. Reversible Motors. Electromagnetic Brake Motors

Brushless DC Motor and Driver Package

Compact Linear Actuators

Brushless Motors. Brushless Motors/AC Speed Control Motors. Brushless Motors/AC Speed Control Motors D-11. AC Input BX Series. AC Input BLF Series

Additional Information. Stepping Motors. Technical Reference F-1 General Information G-1. Motor & Driver Packages.

5-Phase Stepping Motor and Driver Package RK Series

56 mm sq. (2.20 inch sq.)

Brushless DC Motor Systems

Accessories. Standard AC Motors A-287. Standard AC Motors Introduction. Accessories

RoHS-Compliant Brushless Motor Systems FBL Series. Features

HBL 5 60 N - 5. Brushless Motor and Driver Package. Features. Product Number Code A-126 ORIENTAL MOTOR GENERAL CATALOGUE. Standard AC Motors

56 mm sq inch sq.

SKA DDR SKA DDR SKA DDR SKA DDR SKA DDR SKA DDR SKA DDR

5-Phase Stepping Motor and Driver Package CRKSeries 24 VDC Photocoupler Input 1-Pulse/2-Pulse Input Specifications

MB Series AC Centrifugal Blowers

St epping Mot or s C-i ORIENTAL MOTOR GENERAL CATALOG 2009/2010

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

BRAKE MOTORS. 1. Brake motors TECHNICAL CATALOGUE. M Series / Standard / IEC

C -5 to +55 (0.8 to 1.1Uc) Permissible o

5-Phase Stepper Motor

RoHS-Compliant 2-Phase Stepping Motors PK Series

ORIENTAL MOTOR GENERAL CATALOGUE

Limit Switch A. Dog a

BLE Series D-42. Brushless Motor and Driver Package. Features Speed Control Range of r/min (Speed ratio 40:1) Energy Savings

LUYANG Mach. & Elec. Co., Ltd. Luson Motion System Ltd.

BX Series D-62. Brushless Motor and Driver Package. Features Speed Control. Position Control D-62

Accessories. Standard AC Motors A-247. Standard AC Motors Introduction. Flexible Couplings. Others

International Motors/Gearmotors/Controls

High-Efficiency AR Series. RK Series /0.72 /Geared. CRK Series. RBK Series. CMK Series. 2-Phase Stepping Motors A-278.

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12).

Connection and Operation Names and Function of Parts

42 mm sq inch sq.

AC servo systems P Series

Protection against mechanical impacts IK 08 according to IEC 68, EN Insulation class Class F (155 C), class H (180 C) on request.

VA9203-AGx / VA9203-Bxx / VA9203-GGx

30 W/60 W/120 W. RoHS-Compliant Brushless DC Motor and Driver Package with Digital Operator BLF Series

QL (AZ4) Limit Switches

Explosion and flame-proof cast iron electric motors

Introduction to Armature Actuated Brakes (AAB) Operating Principle. Engaged Condition (power off) Disengaged Condition (power on)

SMH80S AAK-3AKH SMH80S ABK-3AKH

Technical Information

E180 DIAMETER FRAMES

SPV Series. Motorized Linear Slides. Features

Technical Explanation for Inverters

ECP180 Series. Low 1 Profile. High Power Density. 2.0 by 4.0 Footprint. 120W Convection-cooled Rating. 180W Force Cooled Rating

Catalog Mars Low voltage Brake motors

Stepping Motor and Driver Package. High-Efficiency AR Series. DC Power-Supply Input. Built-in Controller Type Pulse Input Type

Transcription:

Electromagnetic Brake Motors This power off, electromagnetic brake coupled to reversible motors and induction motors (three-phase type) provides output of W W (three-phase: W W). These motors are best suited for applications in which loads must be held. Features These motors incorporate C electromagnetic brakes which are activated when the power is shut off. When the power supply is turned off the motor stops and holds the load. Holding brake force is. oz-in ( mn m). oz-in ( mn m). These units are excellent as emergency safety brakes. Structure Magnet Coil Spring Brake Hub Brake Lining rmature GER LOD HOLD SFETY STD. C INPUT Safety Standards and CE Marking For -WMU, -ME, -SWM Type Standards Certification Body Standards File No. CE Marking UL UL (W) E (W) UL7 (W~W) UL E7 (W W) CN/CS-C. No. CN/CS-C. No.77 EN EN- EN- IEC- For -MUL Type VDE DEMKO ÜG (W) 7ÜG (W~W) /DK- (Three-phase W) Low Voltage Directive Certification Standards Standards File No. CE Marking Body UL E (W) UL (W) UL E7 (W W) UL7 (W~W) CN/CS-C. No. CN/CS-C. No.77 EN Conform to EN/IEC Standards (EN/IEC certifications are scheduled) Recognized name and certified name of each safety standards are motor model name. CS VDE LR7 7ÜG (W) 7ÜG (, W) 7ÜG (W) 7ÜG (, W) For installation condition for EN/IEC standards, see page D-. Low Voltage Directive The figure above indicates an example of the structure of the electromagnetic brake motor. The electromagnetic brake operates on the basis of a spring which presses the armature against the brake hub, stopping the motor and holding the load. When the electromagnetic brake is excited, it attracts the armature and the brake lining is pulled away from the brake hub. The motor is able to turn freely. Construction Flexible Coupling (Sold separately) Page - Motor Mounting Bracket (Sold separately) SOL type Page - (Included) Motor Gearhead (Sold separately) Cap (Included) - - ORIENTL MOTOR GENERL CTLOG

Product Number Code RKGN - W M U Output Power Example : W Motor Series K: K series Motor Type I : Induction motor R: Reversible motor Motor Frame Size :. in. ( mm sq.) :.7 in. (7 mm sq.) :. in. ( mm sq.) :. in. ( mm sq.) Provided U: V/VC E: V/VC None: Three-Phase type M: Electromagnetic Brake Voltage W: Single-Phase V/V/VC, Poles : Single-Phase V/V/VC, Poles SW: Three-Phase V/V/VC, Poles Motor Shaft Type GN: GN type (for use with GN type gearhead) GU: GU type (for use with GU type gearhead) : Round shaft Note : The "U" and "E" at the end of the model number indicate that the unit includes a capacitor. These two letters are not listed on the motor nameplate. Gearhead GNK Type of bearings or shaft direction. K: Ball bearing type (inch size) R: Right angle gearhead (inch size) RH: Hollow shaft type Gear Ratio Example : Gear ratio of : X denotes the decimal gearhead of gear ratio : Gearhead Type GN: GN type (for use with GN type pinion shaft motor) GU: GU type (for use with GU type pinion shaft motor) Gearhead Frame Size :. in. sq. ( mm sq.) :. in. sq.( mm sq.) :.7 in. sq. (7 mm sq.) :. in. sq. ( mm sq.) Note : The GU type includes two types of model number: box-shaped models with a "B" at the end of their model number and models with mounting flanges with nothing at the end of their model number. ll other series consist of box-shaped models only and have nothing at the end of their model number. See page for data regarding inch size gearheads shafts. For -MUL Type RKGN - M UL Output Power Example : W Motor Series K: K series Motor Type R: Reversible motor UL: UL recognized M: Electromagnetic Brake Voltage : Single-Phase VC, Poles Motor Frame Size :. in. ( mm sq.) :.7 in. (7 mm sq.) :. in. ( mm sq.) :. in. ( mm sq.) Motor Shaft Type GN: GN type (for use with GN type gearhead) GU: GU type (for use with GU type gearhead) : Round shaft - ORIENTL MOTOR GENERL CTLOG -

Motor Specifications Minute Rating Mode Pinion Shaft Type Round Shaft Type Output Power HP W Voltage VC Frequency Hz Current Starting Torque oz-in mn m Rated Torque oz-in mn m Rated Speed r/min µf ZP RKGN-WMU ZP RKGN-ME ZP RKGN-MUL TP RKGN-WMU TP RKGN-MUL TP RKGN-WMU TP RKGN-ME TP IKGN-SWM TP RKGN-MUL TP RKGN-WMU TP RKGN-ME TP IKGN-SWM TP RKGN-MUL TP RKGU-WMU TP RKGU-ME TP IKGU-SWM TP RKGU-MUL TP RKGU-WMU TP RKGU-ME TP IKGU-SWM TP RKGU-MUL RK-WMU RK-ME RK-MUL RK-WMU RK-MUL RK-WMU RK-ME IK-SWM RK-MUL RK-WMU RK-ME IK-SWM RK-MUL RK-WMU RK-ME IK-SWM RK-MUL RK-WMU RK-ME IK-SWM RK-MUL / / / / / / / / / /. /. /. /. /. /. /. /. / / / / Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Three-Phase Three-Phase Three-Phase Three-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Three-Phase Three-Phase Three-Phase Three-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Three-Phase Three-Phase Three-Phase Three-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Three-Phase Three-Phase Three-Phase Three-Phase Single-Phase......7.......................7..7...................7.......... 7... 7.......7............. 7. 7. 7.. 7 7 7 7 7.7.7..7............ 7...7..7.............. 7. 7. 7. 7. 7 7 7 7 7 7 7 7 7.... 7. 7 : These motors are impedance protected. : These motors contain a built-in thermal protector. If a motor overheats for any reason, the thermal protector is opened and the motor stops. When the motor temperature drops, the thermal protector closes and the motor restarts. Be sure to turn the motor off before inspecting. The "U" and "E" at the end of the model number indicate that the unit includes a capacitor. These two letters are not listed on the motor nameplate. When the motor is approved under various safety standards, the nameplate is adopted. colored background indicates gear shaft rotation in the same direction as the motor shaft; a white background indicates rotation in the opposite direction. - - ORIENTL MOTOR GENERL CTLOG

Motor General Specifications For -WMU, -ME, -SWM Type Item Insulation Resistance Dielectric Strength Temperature Rise Insulation Class Overheat Protection Device mbient Temperature Range mbient Humidity Degree of protection Specifications M Ω or more when V DC is applied between the windings and the frame after rated motor operation under normal ambient temperature and humidity. Sufficient to withstand.kv at and Hz applied between the windings and the frame after rated motor operation under normal ambient temperature and humidity. F ( C) or less measured by the resistance change method after the temperature of minute no load operation of motor with connecting a gearhead or equivalent heat radiation plate. Class B F ( C) RK type is impedance protected. Built-in thermal protector (utomatic return type) Open: F F ( C C) Close: 7. F 7 F ( C C) F F ( C C) Three-Phase V : F F ( C C) % Maximum (noncondensing) RK, RK, RK, IK, RK, IK type : IP RK, IK, RK, IK type : IP Motor General Specifications For -MUL Type Item Insulation Resistance Dielectric Strength Temperature Rise Insulation Class Overheat Protection Device mbient Temperature Range mbient Humidity Specification M Ω or more when V DC is applied between the windings and the frame after rated motor operation under normal ambient temperature and humidity. Sufficient to withstand.kv at Hz and Hz applied between the windings and the frame after rated motor operation under normal ambient temperature and humidity. F (7 C) or less measured by the resistance change method after the temperature of the coil has stabilized under normal operation at the rated voltage and frequency. UL CS Standard Class, EN Standard Class E RK type is impedance protected. Built-in thermal protector (utomatic return type) Open: F F ( C C) Close: 7. F 7 F (77 C C ) F F ( C C) % Maximum (noncondensing) Equivalent heat radiation plate (material : luminum) Type (output) RK Type (W) RK Type (W) IK, RK Type (W) IK, RK Type (W) IK, RK Type (W) IK, RK Type (W) Size inch (mm).. ( ).. ( ).. ( ).. ( ) 7.7 7.7 ( ) 7.7 7.7 ( ) Thickness inch (mm). ( ) Electromagnetic Brake Specifications Model RKGN-WMU RK-WMU RKGN-ME RK-ME RKGN-MUL RK-MUL RKGN-WMU RK-WMU RKGN-MUL RK-MUL RKGN-WMU RK-WMU RKGN-ME RK-ME IKGN-SWM IK-SWM RKGN-MUL RK-MUL RKGN-WMU RK-WMU RKGN-ME RK-ME Voltage Frequency Current Input Holding Brake Torque VC Hz W oz-in mn m Single-Phase. Single-Phase.. Single-Phase Single-Phase Single-Phase Single-Phase......... Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase....... 7......... 7................ 7. 7. 7. 7. 7. Model IKGN-SWM IK-SWM RKGU-MUL RK-MUL RKGU-WMU RK-WMU RKGU-ME RK-ME IKGU-SWM IK-SWM RKGU-MUL RK-MUL RKGU-WMU RK-WMU RKGU-ME RK-ME IKGU-SWM IK-SWM RKGU-MUL RK-MUL Voltage Frequency Current Input Holding Brake Torque VC Hz W oz-in mn m Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase......7 7. 7. 7. 7. 7.7 Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase Single-Phase.................... 7 7.7 7 7.7................... - ORIENTL MOTOR GENERL CTLOG -

Gearmotor Torque Table The permissible torque with decimal gearhead with a gear radio of is : GN K: lb-in / N m GN K: lb-in / N m GN K: lb-in / N m (for /~/: lb-in / N m) GN K: 7 lb-in / N m GU K: lb-in / N m Single-Phase /V, Three-Phase V Hz Unit Upper values: lb-in/lower values: N m Speed r/min 7 Model Gear Ratio. 7.. 7 RKGN-WMU / GN K RKGN-ME / GN K RKGN-MUL / GN K RKGN-WMU / GN K RKGN-MUL / GN K RKGN-WMU / GN K RKGN-ME / GN K IKGN-SWM / GN K RKGN-MUL / GN K RKGN-WMU / GN K RKGN-ME / GN K IKGN-SWM / GN K RKGN-MUL / GN K RKGU-WMU / GU K RKGU-ME / GU K IKGU-SWM / GU K RKGU-MUL / GU K RKGU-WMU / GU K RKGU-ME / GU K IKGU-SWM / GU K RKGU-MUL/ GU K Single-Phase V Hz Model Speed r/min Gear Ratio RKGN-ME / GN K RKGN-ME / GN K RKGN-ME / GN K RKGU-ME / GU K RKGU-ME / GU K.7..7...............7.......................77.....7..7........7.7..7..7..7..7.......7..7.7..........7..7...7..........................7. 7... 7.7..7...... 7.. 7...7.7.7.7.... 7 7.........7.............7..7..........7.. 7.... 7.........7.77..... 7..... 7.......... Gearheads are sold separately. Enter the gear ratio in the box ( ) within the model number. colored background indicates gear shaft rotation in the same direction as the motor shaft; a white background indicates rotation in the opposite direction. The speed is calculated by dividing the motor s synchronous speed ( Hz: r/min) by the gear ratio. The actual speed is % less than the displayed value, depending on the size of the load. Right-ngle gearheads may be connected to W, W, W and W motors. See page - for more information regarding the use of gearheads, maximum permissible torque, permissible overhung load and permissible thrust load............7.7...7....7.7.............7......... 7. 7.. 7. 7. 7...... 7....... 7.................... 7 7.7 7. 7. 7...7.....7..7. 7..7 7. 7.....7.7.7.7.7...7 7.. 7 7...7.7 7. 7.. 7.. 7.....7.7....7.7.7 7 7 7. 7......7.....7...... 7...... 7 7. 7. 7. 7.... 7..... 77. 7. 7. 7. 7 7.. 7......7.7.. 7 7 7 7 7. 7..7 7. 7. 7 7 7 7 7 7 7. 7... 7 7 7 7. 7.7.7. 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 Unit Upper values: lb-in/lower values: N m 7 - - ORIENTL MOTOR GENERL CTLOG

Wiring Diagrams RKGN-WMU RKGN-ME RKGN-WMU RKGN-WMU RKGN-ME RKGN-WMU RKGN-ME RKGU-WMU RKGU-ME RKGU-WMU RKGU-ME Line R C C SW R C ON SW ON R C C White Red Black Motor Orange Electromagnetic Orange Brake SW No. SW SW Ro. Co Surge absorber Specifications of Switches Single-Phase VC Single-Phase VC Single-Phase VC Single-Phase VC VC Min VC. Min Inductive Inductive Ro=~ Co=.~. F WV Note Single-pole-double -throw switch ccessories EPCR- Run/Stop: SW operates motor and electromagnetic brake action. Motor will rotate when SW is switched to ON (short circuit). When SW is switched to OFF (open), the motor is stopped immediately by the electromagnetic brake and holds the load. If you wish to release the brake while the motor is stopped, apply voltage between only two brake lead wires (orange). The electromagnetic brake is released and the motor shaft can be rotated easily by hand. Direction of Rotation: To rotate the motor in a clockwise () direction, switch SW to. To rotate it in a counterclockwise (C) direction, switch SW to C. Direction of motor rotation are shown when the motor is viewed from the shaft end of the motor. IKGN-SWM IKGN-SWM IKGU-SWM IKGU-SWM R (U) S (V) T (W) R SW R R C C C C White Red Black Orange Orange Motor Electromagnetic Brake Specifications of Switch VC Min Inductive Ro= Co=.. F WV Single-pole-double -throw switch ccessories EPCR- Run/Stop: SW operates motor and electromagnetic brake action. Motor will rotate when SW is switched to ON (short circuit). When SW is switched to OFF (open), the motor is stopped immediately by the electromagnetic brake and holds the load. If you wish to release the brake while the motor is stopped, apply voltage between only two brake lead wires (orange). The electromagnetic brake is released and the motor shaft can be rotated easily by hand. Direction of Rotation: To change the rotation, change any two connections between U, V and W. SW No. SW Ro. Co Surge absorber Note RKGN-MUL RK-MUL RKGN-MUL RK-MUL RKGN-MUL RK-MUL RKGN-MUL RK-MUL RKGU-MUL RK-MUL RKGU-MUL RK-MUL Line R C R C C SW Line R R C SW C R C SW C ON ON SW ON R C C White Yellow Black Orange Orange C White Gray Black Yellow Yellow Motor Electromagnetic Brake Motor Run/Stop SW operates motor and electromagnetic brake action. Motor will rotate when SW is switched to ON (short circuit). When SW is switched to OFF (open), the motor is stopped immediately by the electromagnetic brake and holds the load. If you wish to release the brake while the motor is stopped, apply voltage between only two brake lead wires (orange or yellow). The electromagnetic brake is released and the motor shaft can be rotated easily by hand. Direction of Rotation To rotate the motor in a clockwise () direction, switch SW to. To rotate it in a counterclockwise (C) direction, switch SW to C. Directions of motor rotation are shown when the motor is viewed from the shaft end of the motor. SW No. SW Ro. Co Surge absorber Specifications of Switch VC Min (W W) VC Min (W, W) Inductive Ro= Co=.. F WV Note Single-pole-double -throw switch ccessories EPCR- Variation in braking time according to connection Connection can be simplified by using the wiring diagram shown in figure w, rather than the normal wiring shown in figure q. Using the connection shown in figure w, however, results in a msec. increase in braking time over that shown in figure q, with a corresponding increase in overrun. The reason for this is that the electromagnetic energy of the motor continues to have an effect on the coil of the electromagnetic brake, so that the electromagnet continues to operate for msec. even though the excitation has been canceled. The brake therefore takes longer to engage. q Normal Connection Line SW SW R R R R C C C ON C C C White Red Black Motor Orange Electromagnetic Orange brake w Simplified Connection Line SW SW R R R C C ON C C C White Red Black Motor Orange Electromagnetic Orange brake - ORIENTL MOTOR GENERL CTLOG -

Starting and Braking Characteristics s an example, we have calculated the motor starting time, braking time and overrun when driving an inertial load (J L = 7 oz-in ) for the motor RKGN-MUL when combined with the gearhead GNK. The overrun of the motor shaft based on the graph on the next page is: NM. revolutions of gearhead output shaft is: N G NM.. revolutions ( ) i J L Gearhead Motor GNK RKGN-MUL First, convert load inertia to its corresponding value at the motor shaft. JM JL 7. [oz-in ] i J L : Inertia of the load [oz-in ] J M : Inertia at motor shaft [oz-in ] i : Gear ratio Starting time and braking time Using the graph again gives: Starting time t msec Braking time t msec The starting time of an electromagnetic brake motor is equal to the motor starting time plus the electromagnetic brake release time. If the electromagnetic brake is left released, the motor can be started much faster. Optimum time for release of the brake is at least msec. before starting up the motor. RKGN-WMU RKGN-ME RKGN-WMU RKGN-MUL Single-Phase Hz Single-Phase Hz Single-Phase Hz Single-Phase Hz..... [ oz-in ]..... [ oz-in ].......7.. [ kgm ].. [ kgm ] RKGN-WMU RKGN-MUL RKGN-ME IKGN-SWM Single-Phase Hz Single-Phase Hz Three-Phase Hz Three-Phase Hz..... [ oz-in ]..... [oz-in ] [ kgm ] [ kgm ] - - ORIENTL MOTOR GENERL CTLOG

RKGN-WMU RKGN-MUL RKGN-ME IKGN-SWM Single-Phase Hz Single-Phase Hz Three-Phase Hz Three-Phase Hz [oz-in ] [oz-in ] RKGU-WMU RKGU-MUL 7 [ kgm ] RKGU-ME Single-Phase Hz Single-Phase Hz IKGU-SWM 7 [ kgm ] Three-Phase Hz Three-Phase Hz [oz-in ] 7 [ kgm ] [oz-in ] 7 [ kgm ] RKGU-WMU RKGU-MUL / RKGU-ME IKGU-SWM Single-Phase Hz Single-Phase Hz Three-Phase Hz Three-Phase Hz [oz-in ] [oz-in ] 7 [ kgm ] 7 [ kgm ] - ORIENTL MOTOR GENERL CTLOG -7

Dimensions Scale /, Unit = inch (mm) Motor Gearhead RKGN-WMU Weight (Mass):. lb. (. kg) RKGN-ME Weight (Mass):. lb. (. kg) GN K RKGN-MUL Weight (Mass):. lb. (. kg) Weight (Mass):. lb. (. kg) Round Shaft Type RK-WMU Weight (Mass):. lb. (. kg) RK-ME RK-MUL Weight (Mass):. lb. (. kg).di.( ).().(7) L.().().(.7).(7.7).DI. /".DI. ( 7.7.). (). DI. ( ).. ( ).7DI..7DI. ( 7.).(). (.).DI..DI. (.).. ( ).7DI..7DI. ( 7.) ()-LEDS UL Style, WG ()-BRKE LEDS UL Style, WG L. () GNK K L.7 () GNK K.77DI.(.)-.77HOLES ' Model RK-WME RK-ME RK-MUL.77 DI.(.)-HOLES.DI..7DI..DI..DI. - ( ). ' - [/"] (. ) Unit = inch (mm). Motor Gearhead RKGN-WMU Weight (Mass):. lb. (. kg) GN K RKGN-MUL Weight (Mass):. lb. (. kg) Weight (Mass):. lb. (. kg) Round Shaft Type RK-WMU Weight (Mass):. lb. (. kg) RK-MUL Weight (Mass):. lb. (. kg).7di.( 7).7().(7) L.().().(.7).(.).7DI..7DI. /" (..). (). DI. ( ).7.7 (7 7).DI..DI. (.).().().7DI..DI. (.).7.7 (7 7).DI..DI. (.) ()-LEDS UL Style 7, WG ()-BRKE LEDS UL Style, WG L. () GNK K L. () GNK K.7DI.(.)- HOLES '.7DI.(.)-HOLES Model RK-WMU.DI..7DI. RK-MUL.DI..DI. - ( ). ' - [/"] (. ) Unit = inch (mm). Decimal Gearheads GNXK Weight (Mass):. lb. (. kg) GNXK Weight (Mass):. lb. (. kg).(.).().(.). ().DI..DI. (.).. ( ).7DI..7DI. ( 7.).().().(). ().7DI..DI. (.).7.7 (7 7).DI..DI. (.).77DI.(.)-HOLES.7DI.(.)-HOLES - - ORIENTL MOTOR GENERL CTLOG

Motor Gearhead RKGN-WMU Weight (Mass):. lb. (. kg) RKGN-ME Weight (Mass):. lb. (. kg) GN K IKGN-SWM Weight (Mass):. lb. (. kg) RKGN-MUL Weight (Mass):. lb. (. kg) Weight (Mass):. lb.(. kg).di.( 7).().(7) L.().().(.7).7(.).7DI..7DI. /" (..). ().DI. ( ).. ( ).7DI..DI. (.) ()-BRKE LEDS UL Style, WG.7DI.(.)- HOLES ()-LEDS UL Style 7, WG ' L. () GNK K L.7 (.) GNK K Decimal Gearheads GNXK Weight (Mass):. lb. (. kg).7(.).().(.). ().7DI..7DI. ( 7.).. ( ).7DI..DI. (.) Round Shaft Type RK-WMU Weight (Mass):. lb. (. kg) RK-ME Weight (Mass):. lb. (. kg) IK-SWM Weight (Mass):. lb. (. kg) RK-MUL Weight (Mass):. lb. (. kg).().(). () B.7DI..7DI. ( 7.).. ( ).7DI..DI. (.).7DI.(.)-HOLES.7DI.(.)-HOLES ' Unit = inch (mm) Model B RK-WME.DI. RK-ME.DI. ( -. ) RK-SWM. (7) RK-MUL.DI. [/"] ( 7.7 -. ).DI.. (7.7) - ORIENTL MOTOR GENERL CTLOG -

Motor Gearhead RKGN-WMU Weight (Mass):. lb. (. kg) RKGN-ME Weight (Mass):. lb. (. kg) GN K IKGN-SWM Weight (Mass):. lb. (. kg) RKGN-MUL Weight (Mass):. lb. (. kg) Weight (Mass):. lb. (. kg).di.( ).().(7.) L.().().7 ().(.).DI..DI. /" (.7.).7 ().DI. ( ).. ( ).DI..7DI. (.) ()-BRKE LEDS UL Style, WG.DI.(.)- HOLES ()-LEDS UL Style 7, WG ' L. () GNK K L. () GNK K GNXK Weight (Mass):. lb. (. kg).7()..7() (7). ().. ( ) Round Shaft Type RK-WMU Weight (Mass):. lb. (. kg) RK-ME Weight (Mass):. lb. (. kg) IK-SWM Weight (Mass):. lb. (. kg) RK-MUL Weight (Mass):. lb. (. kg).77di..di. (.).DI..7DI. (.).DI.(.)-HOLES.(7).(). ().77DI..DI. B (.).. ( ).DI..7DI. (.).DI.(.)-HOLES ' Unit = inch (mm) Model B RK-WME.7DI. - RK-ME (. ).DI. IK-SWM. () RK-MUL.7DI. [/"] (. -. ).7DI.. (.) - - ORIENTL MOTOR GENERL CTLOG

Motor Gearhead RKGU-WMU Weight (Mass): 7. lb. (. kg) RKGU-ME Weight (Mass): 7. lb. (. kg) GU K IKGU-SWM Weight (Mass): 7. lb. (. kg) RKGU-MUL Weight (Mass): 7. lb. (. kg) Weight (Mass):. lb. (. kg).().().(7.).().(7). (.).DI. /".DI. (.7.).7 ().DI. ( ).. ( ).. ( ).DI..7DI. (.). (.).DI.(.)-HOLES ()-CBTYRE CBLE.DI.( ) Motor Lead wire, UL Style 7, WG ( Brake Lead wire, UL Style, WG) Cable direction can be switched to the opposite direction.. (7). (.) Key and Key Slot The key is provided with the gearhead...7 (..).. (.7.).... (.7 )... (.7.)... (.7 ) Round Shaft Type RK-WMU Weight (Mass): 7. lb. (. kg) RK-ME Weight (Mass): 7. lb. (. kg) IK-SWM Weight (Mass): 7. lb. (. kg) RK-MUL Weight (Mass): 7. lb. (. kg).(7).().7di..77di. (.).. ( ).. ( ). ().().77DI..DI. (.).DI..7DI. (.).DI.(.)-HOLES. (7). (.) Decimal Gearheads GUXKB Weight (Mass):. lb. (. kg).().7.() (). ().. ( ).77DI..DI. (.).DI..7DI. (.).DI.(.)-HOLES - ORIENTL MOTOR GENERL CTLOG -

Motor Gearhead RKGU-WMU Weight (Mass):. lb. (. kg) RKGU-ME Weight (Mass):. lb. (. kg) GU K IKGU-SWM Weight (Mass):. lb. (. kg) RKGU-MUL Weight (Mass):. lb. (. kg) Weight (Mass):. lb. (. kg) 7.(7).().(7.).().(7). (.).DI..DI. /" (.7.).7 ().DI. ( ).. ( ).. ( ).DI..7DI. (.). (.) ()-CBTYRE CBLE.DI.( ) Motor Lead wire, UL Style 7, WG ( Brake Lead wire, UL Style, WG) Cable direction can be switched to the opposite direction..di.(.)-holes. (7). (.) Key and Key Slot (provided with the gearhead.)..7 (..).. (.7.).... (.7 )... (.7.)... (.7 ) Round Shaft Type RK-WMU Weight (Mass):. lb.(. kg) RK-ME Weight (Mass):. lb.(. kg) IK-SWM Weight (Mass):. lb.(. kg) RK-MUL Weight (Mass):. lb.(. kg).(7).().7di..77di. (.).. ( ).. ( ). ().().77DI..DI. (.).DI..7DI. (.).DI.(.)-HOLES. (7). (.) Decimal Gearheads GUXKB Weight (Mass):. lb. (. kg).().7.() (). ().. ( ).77DI..DI. (.).DI..7DI. (.).DI.(.)-HOLES - - ORIENTL MOTOR GENERL CTLOG

(included with the motor) B.DI.DI..7.7 (.) (.) () ().().().(.).() C B+.(). () B B+.().(7). ().() C R.().DI. (.).7 ().(). B C.() (.) B.().DI. (.).7 ().(). B C.() (7) B.() Motor Model Pinion Shaft Type Round Shaft Type RKGN-WMU RKGN-ME RKGN-MUL RKGN-WMU RKGN-MUL RKGN-WMU RKGN-ME RKGN-MUL RKGN-WMU RKGN-ME RKGN-MUL RKGU-WMU RKGU-ME RKGU-MUL RKGU-WMU RKGU-ME RKGU-MUL RK-WMU RK-ME RK-MUL RK-WMU RK-MUL RK-WMU RK-ME RK-MUL RK-WMU RK-ME RK-MUL RK-WMU RK-ME RK-MUL RK-WMU RK-ME RK-MUL Model CHFUL CHBFUL CHUL CHCFUL CHUL CHCFUL CHBFUL CH7UL CHCFUL CHBFUL CHUL CHCFUL CHBFUL CHUL CHCFUL CH7BFUL CHUL. (). (). (). (). (7). (). (). (). (). (). (). (). (). (). (). (). () Dimensions inch (mm) B.7 (7).7 (7).7 (.). ().7 ().7 ().7 (). (). ().7 (). (). (). (). (.). (). (). () C. (7). (7). (.). (). (7). (). (). (). (). (). (). (). (). (7).7 ().7 (). () Weight oz. (g)................ 7 No. Right-ngle Gearheads (Sold Separately) The right-angle gearhead provides an output shaft that is at a right angle to the motor s output shaft. See page [-] for specifications and other information. ccessories (Sold Separately) Motor Mounting Brackets Optional die-cast aluminum mounting brackets are available. They can be used to install motors without gearheads. See page[-] for the dimensions. Flexible Coupling Optional clamp-type couplings are available. See page[-] for dimensions. - ORIENTL MOTOR GENERL CTLOG -